2.4 TFT

Add to my manuals
41 Pages

advertisement

2.4 TFT | Manualzz

2.4 TFT Installation Instruction V1.0

2.4 TFT

Installation Instruction

Contents

About this Guide l The User guide is designed to provide information to install the

2.4TFT, for operation and configuration, please refer to the corresponding user’s manual. l Not all function these guides introduce available in combination, all is option.

About your machine function, please consult our company technical personnel or the sales personnel

Information in this document is subject to change without notice.

2.4 TFT Installation Instruction V1.0

Contents

1.Before Installing ................................................................................... 1

1.1 Notice about installing............................................................... 1

2.System Configuration........................................................................... 3

2.1The illustration of system construction ...................................... 3

2.2 The sketch map of communication............................................ 4

3.Installation ............................................................................................ 5

3.1 Fix Mounting Plate.................................................................... 5

3.2 Connect with peripheral equipment........................................... 6

3.2.1 Door sensor connection .................................................. 8

3.2.2 Exit-button connection ................................................... 9

3.2.3 Alarm connection............................................................ 9

3.2.4 Door lock connection ................................................... 10

3.2.5 Ethernet connection ...................................................... 14

3.2.6 RS232 connection......................................................... 17

3.2.7 RS485 connection......................................................... 17

3.2.8 Wiegand output connection .......................................... 19

3.2.9 Connect with external Weigend reader......................... 20

3.2.10 Power connection ....................................................... 20

3.3 Fastening fingerprint machine ................................................. 22

4. Test and examine after installation .................................................... 23

5. Others ................................................................................................ 24

5.1 Reset ........................................................................................ 24

5.2 Anti-dismantle button .............................................................. 24

5.3 Wireless doorbell ..................................................................... 25

5.4 U flash disk using .................................................................... 25

5.5 Built-in EM card reader (Optional) ......................................... 25

5.6 Built-in MIFARE card reader (Optional) ................................ 26

5.7 Built-in HID Card reader (Optional) ....................................... 26

Contents

5.8 Cable doorbell(Optional) ................................................... 27

5.9 Connection with Wi-Fi (optional)............................................ 27

6. Trouble shooting................................................................................ 29

Appendix ............................................................................................... 31

How to configure the Wi-Fi function for the terminal................... 31

2.4 TFT Installation Instruction V1.0

1.Before Installing

1.1 Notice about installing

The terminal is a mass-produced product. It strictly follows to the criteria of manufacture and inspection of China, U.S.A, and EU. This file contains important information. It is better for you to read it carefully prior to use. If you ignore it, the incorrect installation may cause the unit damage. Although we could do our best to offer you service, the neglect to the file could cause unwanted cost for you.

1. Before installation, please make sure the power is cut off, because it is very dangerous if the power is on. The short-circuit of power cable may cause the core parts damage.

2. All exposed part of connection wire end can not be exceeded 5mm to prevent the bared wire accidental connection which leads to machine break down. And also suggest using different colour cable to connect.

3. In the place where the static is strong or in winter, please connect the grounding firstly, in order to prevent the instant mass static damage the machine.

4. Connect power supply with device in the last for the wiring connection. If you find any unusual thing occur, please firstly cut off the power, then go to examine. Keep in mind: wiring operation under power on will lead to machine sudden damage; we are not liable for damages and trouble due to such operation.

5. The height to mount device is about 1.4-1.5 meter

After installation, please take off protection film on the fingerprint sensor to get best recognize result.

- 1 -

Before Installation

6. After installation finish, when go to test the exit-door button, please keep a personal in the outside, because sometimes the accidental issue can bring on you are not able to go outside.

7. Our equipment offer an automatically function, please after the installing finish. Run the auto-test function to confirm the installation finish.

In order to guarantee machine run for long time, we set an auto-sleep and wake up function in the exit factory, please carefully examine this function normally setting before using.

8.We recommend using above the 12V/3A direct-current supply for

ZK software’s access control device, electricity lock better to powered by 12VDC, and no more than 1.5 A electric current At this time, the electric current of supply should be above1A than lock power. If the parameter of lock power surpasses this scope, please connect technical personnel. If the power had not met above requests, it possibly causes to be unable normally to drive the electricity lock, even damage the device.

9. Before device to be connected please read and always follow

"Quick connect Guide" closely. Because the wrong wiring will cause the core block and sensor to burn out, insult in device to break down, at this cause ZK Software is not liable for any damages and trouble.

10. If the space between power adapters and device is too long, please do not use the twisted-pair or other type ferrules for the power wire.

When the power wire is choused, you should consider attenuation of voltage which has passed long distance transfer.

11. Please use specialized RS485 cable and the RS232/485 converter with power to hookup the network, the bus structure apply to connect with each device. When a long cable is used to transfer signal, it is need to connect a matching resistance to receiver, and its value is 120Ώ.

12. Other not details items; please see also the user handbook, the operating instructions and the appendix and so on

- 2 -

2.4 TFT Installation Instruction V1.0

2.System Configuration

2.1The illustration of system construction

- 3 -

System Configuration

2.2 The sketch map of communication

Fingerprint machine directly connects with PC through RS232 or

TCP/IP

Fingerprint machine connects with PC through RS485 network

Fingerprint machine connects with PC through TCP/IP network

- 4 -

2.4 TFT Installation Instruction V1.0

3.Installation

3.1 Fix Mounting Plate

①Take out a fingerprint machine,dismantle the screw between machine body and mounting plate until it is out, see figure (1).

②Carefully take up the bottom of mounting plate, see figure (2), push it up, see figure (3), then take away the mounting plate.

③Determine the position of mounting plate on the wall. The fingerprint machine should be mounted on the external wall of the door approximately 1400mm from the ground to the unit bottom. After the position is determined, you could drill a hole (18mm*20mm) for cable out, see below figure shadowed part.

④Make the hole of mounting plate meet the drilled hole on the wall,

Use the screw to fix it on the wall, (for the details please see following figure a, b, c, d)

⑤After installation, please make sure the mounting plate is reliable, fasten, not loosed.

Figure 1

- 5 -

Installation

3.2 Connect with peripheral equipment

Caution: Do not to connect peripheral equipment before the power of the device is cut down, otherwise it is possible to damage the

device badly.

Please follow instruction to connect peripheral equipment

① Door sensor connection

② Exit-button connection

③ Alarm connection

④ Door lock connection

⑤ Ethernet connection

⑥ RS232 connection

⑦ RS485 connection

⑧ Wiegand output connection

⑨ Power connection

- 6 -

2.4 TFT Installation Instruction V1.0

Table 1 the definition of the Pin of the terminal connector

J7, 9pin connector on left side above of the rear panel (from the top)

1st NC2 Connect to Alarm NC terminal Tie up

2nd COM2

3rd NO2

Connect to Alarm COM terminal

Connect to Alarm NO terminal together

4th

5th

8th

NC1

COM1

6th NO1

7th Button

GND

9th Sensor

Connect to Lock NC terminal

Connect to Lock COM terminal

Connect to Lock NO terminal

Connect to Release button

For Door sensor and release button

Connect to Door sensor

Tie together up

Tie together up

J1, 2Pin connector on left side below of the rear panel (from the top)

1st GND Connect to Power GND Tie up

2nd +12V Connect to Power +12v together

J2, 4Pin connector on middle above of the rear panel (from the top)

1st RJ45-1 Connect to RJ45 plug wiring 1

2nd RJ45-2 Connect to RJ45 plug wiring 2

3rd RJ45-3 Connect to RJ45 plug wiring 3

4th RJ45-6 Connect to RJ45 plug wiring 6

Tie together up

J12, Pin connector on middle below of the rear panel (from the top)

1st WD0 Connect to Weigand out WD0 Tie up

- 7 -

Installation

2nd WD1

3rd GND

4th RXD

5th TXD

6th GND

7th 485A

8th 485B

Connect to Weigand out WD1

Connect to Weigand out GND

Connect to RS232 RXD

Connect to RS232 TXD

Connect to RS232 GND

Connect to RS485A

Connect to RS485B together

Tie together

Tie together up up

J17, 7Pin connector on right side below of the rear panel (from the top)

1st Bell+

2nd Bell-

Connect to Cable Bell+

Connect to Cable Bell-

Tie together up

3rd BEEP

4th GLED

Spare

Spare

5th RLED Spare

6th INWD0 Connect to Weigand input

7th INWD1 Connect to Weigand input

Tie together up

3.2.1 Door sensor connection

The door sensor is used to detect the door open-close state , the terminal can monitor if the door has been unauthorized open through the door sensor, at this time it can output a alarm signal, moreover, the terminal can trigger prompt warning if after surpassing a timed period , the door still open.

- 8 -

2.4 TFT Installation Instruction V1.0

3.2.2 Exit-button connection

The exit-button is installed for in-door operation. When the switch of the button is close, the door will open. The distance is approximately

1400mm from ground to exit-button bottom. Make sure that the exit-button position is to align correct, upright and the connection is accurate and reliable. (Unused exposed end of cable should be cut off, and use insulating tape to wrap it.)Pay attention to electromagnetic disturbance. (For example: The light switch, the computer and so on)

3.2.3 Alarm connection

the terminal alarm output is a switch signal,it is able to connect with simple alarm by serial circuit, it also apply to top grade alarm and monitor system as a trigger signal( this machine alarm function only support 12 VDC Warner)

- 9 -

Installation

3.2.4 Door lock connection

The way of installing door lock depends on the type of lock and local condition. Internal resistor, which comes from long distance transfer, should be taken into consideration when selecting the cable of electric power. The door lock should be installed reliable and stable. Ensure the wiring is correct. For the strike lock and electromagnetic lock, you should pay attention to positive and negative terminal connection. The unused bare end of wire should be cut off and use insulating tape to wrap it. The delay time of strike lock is adjustable according to different conditions.

Select electric lock :It is better to use electric drop bolt for the two

–direction opening glass door (both open to inside or outside direction), for the single opening wood door in company internal , we recommend to use magnetic lock, the magnetic lock also be called as electric magnetic lock,. The magnetic lock is more reliable than the electric drop bolt, but the electric drop bolt is much safer than the magnetic lock. In the small living community, it is better to use electric

- 10 -

2.4 TFT Installation Instruction V1.0 drop bolt and magnetic force lock. The electric control lock gives out higher noise; the electric control lock is commonly used to building communication. Now there is a soundless electric control lock which is able to be applied. Please pay attention, the lock is made of iron and easy rust, so you must beware of not exposing it to water or harsh condition, there are some other electric locks available, we don’t recommend you to use them.

Connect with electric lock

Input terminal of release door button (Button GND)The input port of release door button accepts the signal which come from normally opened contact to indicate that somebody want to go out, the input equipment such as “ action detector”, “ press sensitivity floor board” or exit-door button all serve as source to send signal ,if nobody send out request to want to go out, the input keep disconnection , if somebody want to go out, they trigger release door button, the circuit is closed.

Produce state change, the controller responded to the request, unlock and permit door serve as passage mode.

Note :the process of performance to unlock door is control by relay, when you install door lock, there are two thing you must think about,

-- safety and security , in other words, do you want which result that is if lose control of this door, the door is still in safety —“lost control but safety ” or if lose control of this door, the door still is security--- “ lost control but security ”

“Lost control but safety” is that the power supply cut off (maybe the power supply is cut or the controller lose control of itself, the door will be open automatically, and permit everybody freely to pass in and out, the door is not ability to be closed until the system power on, these type of doors are installed in the protective area which ensure everybody is

- 11 -

Installation able to pass in and out. One representative application of “ lost control but safety” is to use electromagnetism lock, under normal power supply, the door is controlled by the controller, once the power supply break off, the electromagnetism lock will lose magnetism and does not take effect, the door become a passage mode

“Lost control but security” is that the power supply cut off, the door will be locked automatically, do not permit external personal to come in, but permit internal personal go out, the door is not to be unlocked until the system power supply is in gear. Make sure that the door of “lost control but security” will be installed in the area, which needs to be protected through fair and foul. One representative application of “ lost control but security” is to use electrical lock, if the power supply break off, the external personal is not able to open the door, but the internal person can open the by manual operation.

The working power of the fingerprint access control terminal is DC12V, and the working current is approximate 400mA. If the working power of the lock is DC12V while its working current is 1000mA much lower than the current of fingerprint machine’s power, it is allowed to fingerprint machine and lock work together by one power supply .

In the following three cases, we recommend that fingerprint machine and lock be powered separately.

1) The working voltage of the lock is DC12V, but the current difference of the fingerprint machine and the lock doesn’t exceed 1A.

2) The lock voltage is not DC12V.

3) The distance between lock and fingerprint machine is too far.

- 12 -

2.4 TFT Installation Instruction V1.0

- 13 -

Installation

3.2.5 Ethernet connection

The terminal provide two ways connect Ethernet

1).the terminal connects with PC through cross cable

- 14 -

2.4 TFT Installation Instruction V1.0

2)the terminal connects with PC through network and HUB to create a local network

3) RJ45 plug wiring diagrams for Ethernet a) RJ45 plug standard

- 15 -

Installation b) Ethernet 10/100Base—T Crossover Cable mostly apply to HUB and Switch,or directly connect two Ethernet terminals(not through HUB), fully support 10Base-T and 100Base-TX.

Plug1 Pin Pin Plug 2

TX+ 1 <——> 3 RX+

TX- 2 <——> 6 RX-

RX+ 3 <——> 1 TX+

RX- 6 <——> 2 TX- c) Ethernet 10/100Base-T Straight Thru Cable

Support 10Base-T and 100Base-TX,apply to connect with network card

Wiring standard Pin Color Pin Wiring standard

TX+ 1 <— white orange —> 1 TX+

TX- 2 <— Orange —> 2 TX-

RX+ 3 <— white green —> 3 RX+

4 <— Blue —> 4

5 <— Blue white —> 5

RX- 6 <— Green —> 6 RX-

7 <— White brown —> 7

8 <— Brown —> 8

- 16 -

2.4 TFT Installation Instruction V1.0

3.2.6 RS232 connection

The definition of PC connection with fingerprint machine

PC Serial Port Fingerprint machine serial port(J12)

Pin2-Rxd

Pin3-Txd

Pin5-Gnd

Pin5-Txd

Pin4-Rxd

Pin6-Gnd

3.2.7 RS485 connection

RS-485 systems using a bus structure configuration connect the driver to the receiver. The transmission line is made by a group of pair-twisted cable. Each transmitted signal has a pair of conductors consisting of inverted and non-inverted signal lines. The inverted line is generally indicated by the index "A" or "-", with the non-inverted line designated

- 17 -

Installation as "B" or "+". The receiver simply evaluates the difference between the two lines, so that common mode noise on the transmission line will not result in a falsifying of the actual signal, however, on the line may be produced a difference mode disturbing. In order to eliminate this disturbance, traditional RS485 networks require a 12Ω terminal resistor to be installed at the end of the bus cables based on the physical layout of the pair-twisted cables. In the normal condition the resistor is not installed, only if the bus is extended to over 100 meters, the termination must be connected with a terminal resistor.

The define of terminal connection

Terminal(J12)

Pin7-485A

Function

RS-485 communication +

Pin8-485B RS-485 communication -

- 18 -

2.4 TFT Installation Instruction V1.0

3.2.8 Wiegand output connection

The terminal provides standard Wiegend 26 output, which can be connected to most of access controllers, like the way of connecting with a ID reader or password keyboard. The distance from the controller to device can not be more than 15 meter (if the signal must be transferred much further or there is a strong interference around, please adopt a wiegand signal amplifier)

Mote: no matter the device is powered by access controller or not, the ground ports of them have to be properly together to ensure the weigand transfer reliable

TerminalJ12

Pin1-WD0

Pin2-WD1

Pin3-GND

Function

Output wiegand data 0 signal

Output wiegand data 1 signal

Ground

- 19 -

Installation

3.2.9 Connect with external Weigend reader

Access control device whit the Weigand input function is able to connect with card reader, which is located in outdoor or indoor, control the door by the controller together, the cable which between access controller and external card reader is no more than 90 meter.

3.2.10 Power connection

This device is powered by 12VDC. Its current is approximately 50mA in the ready work status and 400mA in the work status. The power is conducted along with the terminal; you can use the 12V-4A supply adapter which is provided along with the device. The detail about connection is as follow.

Terminal(J1)

Pin1- GND

Function

Power negative

Pin2- PWR Power positive

The following figure is an example which takes a provided power adapter to connect to the terminal:

- 20 -

2.4 TFT Installation Instruction V1.0

- 21 -

Installation

3.3 Fastening fingerprint machine

① Confirm all connection plugs correctly.

② Align back iron-plate of fingerprint machine body to mounting plate properly, and push it up, see figure1,: then push device backward, see figure 2.

③ Turn and tie up the screw bottom.

After finishing installation, make ensure the body of device is fixed tightly.

- 22 -

2.4TFT Installation Instruction V1.0

4. Test and examine after installation

After all system installation finished, make a test and examine prior to power on , inspect whether the lock driver is OK or not, for more details, please see “User Guide” and “Software Manual”

①the green LED begins to glitter after power up.

②enter menuàOptionà Auto-test.

③enter menuàUser manageàUser EnrollàFingerprint Enroll,Enroll a fingerprint, and use the fingerprint to test access control system and door lock..

④if there is no any problem. Please delete this enrolled fingerprint.

- 23 -

Others

5. Others

5.1 Reset

Due to operation error or other accidence, which leads the machine not to work, you can restart machine through reset key.

①take a small tool which diameter is no more than 2mm.

②find reset mark of “res” on the left small hole on the bottom of device, see following figure.

③Use the tool plug into the hole refer to the picture on right , then plug out. The machine is able to restart.

5.2 Anti-dismantle button

Anti-dismantle button is on middle of device, whose function is realized by back-cover pressing the anti-dismantle button. When the device is being dismantled, it will send a alarm signal through the terminal.

- 24 -

2.4TFT Installation Instruction V1.0

5.3 Wireless doorbell

Put the doorbell in the proper place, press the doorbell key on the device, please see red circle mark, after the doorbell receive a signal, it will ring.

Bell

Note: the doorbell is a wireless, so the distance from device to doorbell can not be too far, it will impact the receiver of doorbell signal if there is shield barrier.

5.4 U flash disk using

①there is a mini-port of USB, please see figure circle on the left.

②Use USB converter to change mini-port into standard USB port. see following figure.

③USB can be used to upload and download data by U disk, can be connected with U.are.U fingerprint sensor as an external fingerprint sensor.

5.5 Built-in EM card reader (Optional)

Built-in a contact less EM card reader module, the distance of flashing

- 25 -

Others card is 5-10 cm. it completely supports the thick card (1.88mm), middle card (1.05mm), and thin card (0.88mm), whose operating frequency is at

125 KHZ, the card area as following illustration.

5.6 Built-in MIFARE card reader (Optional)

Contain a contact-less MIFARE card reader module , the distance to detect card is 5-10cm, it completely supports MIFARE cards that provide operating frequency 13.56MHZ, communication speed

106KBPS, the card area is as following illustration.

5.7 Built-in HID Card reader (Optional)

Built-in a contact-less HID card reader module, the readable range is

5-10cm, it support HID card at operating frequency 125KHZ, the card area is as following illustration.

RF area

- 26 -

2.4TFT Installation Instruction V1.0

5.8 Cable doorbellOptional

There is a key which is remark as icon( ) on the keypad , this key is used for doorbell.

Put the doorbell in the proper place, press the doorbell key on the device, please see circle marked, after the doorbell receive a signal, it will ring.

Note:Because the terminal and key our provided is used for cable doorbell, must join the power into the electric round.

Power

Door Bell

5.9 Connection with Wi-Fi (optional)

This fingerprint machine may provide Wi-Fi, that Short for wireless

fidelity and is meant to be used generically when referring of any type of

802.11 network, whether 802.11b, 802.11a, dual-band, etc. to connect fingerprint machine with LAN, the fingerprint machine is available to directly download data via Wi-Fi. our Wi-Fi Support IEEE 802.11b compliant DBPSK, DQPSK, CCK modulation

- IEEE802.11b Standard Data Rates: 1, 2, 5.5 and 11Mbps.

- 27 -

Others

- Support IEEE 802.11g compliant DSSS, CCK, OFDM modulation

- IEEE802.11g Standard Data Rates: 6, 9, 12, 18, 24, 36, 48,

54Mbps .

For more detail operation ,see Appendix Wi-Fi configure

Note: Unless you have configured the Wi-Fi setting of this fingerprint machine the Wi-Fi communication is invalid when you wish use the

Wi-Fi, Following figure is illustration about how to apply Wi-Fi to the terminal.

- 28 -

2.4TFT Installation Instruction V1.0

6. Trouble shooting

Trouble Cause & Measure

Power LED is off

Device is unable to connect with PC

After device power is on, LCD display always shows “Please try again”.

Startup bar cycles, and can’t enter menu

Cause : No power or lack of voltage

Measure : ① Check and examine the connection of PWR, GND, make sure they contact well. ②Measure the supply voltage, ensure that it is 12VDC.

Cause: The connection problem.

Measure: Check and examine the connection of RS232/RS485 or TCP/IP, whether its connection is correct or not.

Cause : ① For long time used, surface of fingerprint sensor becomes dirty, or there are some scratches on it, the device takes it as a fingerprint and does verification, ②

Fingerprint connection cable of fingerprint sensor is loosed .③ Chip-on-board is broken .

Measure :① Under such situation you can use scotch tape to adhibit the dirt. ②、③

Need to contact suppler and ask for repair.

Cause : ① Fingerprint connection cable of fingerprint sensor insert improperly

②Fingerprint sensor broke down.

③ Chip-on-board is broken

Measure : ① Please take out the Fingerprint

- 29 -

Trouble Shooting

The time display as

“00:00” restarting

The fingerprint sensor light is off after keystroke and press finger without sound connection cable from slot of fingerprint sensor, plug it again. ② 、 ③ It need to contact suppler to repair.

Cause: The clock battery is broke down.

Measure: Contact the reseller to replace a battery.

Cause: ① Fingerprint connection cable of fingerprint sensor connection is broken. ② fingerprint sensor broke down.

Measure: ① Please take out the FFC from slot of fingerprint sensor, plug it again.②

Contact suppler, ask for repair.

Cause: Trouble in the buzzer, loud- speaker or circuit.

Measure: Need to replace the buzzer and loudspeaker.

Some users’ finger- prints sometimes

Cause: The fingerprint quality is poor.

Measure: You’d better select fine fingerprint can’t be verified. (less crinkle, no desquamation, clear image) when enroll fingerprint, make your finger touch fingerprint sensor with larger area, a comparable test should be made after enrollment, we suggest you enroll more fingerprints. By the way our device supports

1:1 match method and password identified function, you could choose one of them

- 30 -

Appendix

2.4TFT Installation Instruction V1.0

How to configure the Wi-Fi function for the terminal

Step1 Before configuration

The terminal serve as a station in the wireless network, before the terminal apply to Network, another physical component of that

802.11 network consist Distribution system, Access Point, Wireless

Medium must exist.

You must know the ESSID (name of network) of local network you want to connect to.

Step2 Operation step

Step 1. Copy the file WiFiConfigure that is along with the product provided by the manufacturer in the PC.

Step 2. Connect the terminal fingerprint machine with the PC over the Ethernet or RS 232

Step 3. Double-click ZKMACUpdata to open this file, the following windowing appear.

- 31 -

Trouble Shooting

Step 3.Activate the software

There are two options Active, Disable on the interface, for wireless End (station) the two options must to be set down.

If you select the Active item, this wireless-end will be activated, you can configure the AP (Access Point) of 802.11 networks.

If you select the Disable, this wireless-end will be invalid; you can set the connection way of the fingerprint machine, and its

- 32 -

2.4TFT Installation Instruction V1.0 configuration of IP address.

Step4 Confirm Network ID

Full the blank of local wireless Network ID you want to connect with any character or figure (capital letter and small letter is different)

Note: must fulfill the blank that is marked with“*”

Step5 Determine Network model there are two option , Infrastructure Model, and Ad-hoc Model, shown as following figure

Hub-and-spoke wireless network

- 33 -

Trouble Shooting

Ad-hoc(peer-to-peer)wireless network click the draw –down box to select the wireless network model, depending on the different topology of network, this Infrastructure Model will apply to Hub and Spoke wireless network, the Ad-hoc Model is used in the peer to peer wireless network..

Step 6.Select the Authentication Type

The Infrastructure Model include five Authentication Type that are

- 34 -

2.4TFT Installation Instruction V1.0

OPEN 、SHARED、 WEPAUTO、 WPAPSK、 WPA2PS. the Ad-hoc Model include OPEN 、SHARED、 WEPAUTO

WPANONE four type of Authentication Type.

Click the draw-down box select the Authentication Type

to

Step 7.Select Encrypt Type

When the item NONE of encrypt Type is selected, then the password in WEP (Wired equivalent privacy) and WPA (WiFi protested access) item is not permitted to modify it, it is not need to input password too.

According to Authentication Type, and Encrypt Type ,Click draw down box to input the password, password comply with the criterion set down by the software.

Note: there are four group passwords in the WEP column, till the all password have been set up is correct, the current password is valid

Step 8Set Connection Parameter

The fingerprint machine fully support two connection ways, one

TCP/IP, anther one is RS 232,.

If you select TCP/IP, here the IP and Port value must to be assigned, its value is same with one in the communication option of the fingerprint machine. Set the option Ethernet in the fingerprint machine to “Yes”.

- 35 -

Trouble Shooting

If you selectRS232, must configure these parameter ,DeviceID、

COMPort、Baud rate same with one in the communication option of the fingerprint machine.

Step9. Configure the wireless Network IP address

Click configMchine this button, the following menu will pop-up

If there is the DHCP function in the 802.11 network Distribution system , you may choose DHCP, press OK to exit.

Otherwise, full the IP Address,Subnet Mask blank with the correct figure, press OK to exit to main interface.

After all setting for wireless network is completed, single –click

SETbutton on the MODEMConfigTool interface, the prompt “ in working” will appear on the fingerprint machine.

After configure successfully, the corresponding message will inform you, click OK to close the message.

- 36 -

2.4TFT Installation Instruction V1.0

Be sure to shut down and restart the machine, so the configureation change take effect.

Step10 View the fingerprint machine Wireless Setting

You can view the fingerprint machine Wireless Setting to get the information of the wireless network communication

Power on the Fingerprint Machine, press menu à System Infoà

Dev Info àwirlesscardàrausb0:

- 37 -

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement