ATS400
ETL DataView 3
User Manual
Contents
Contents
Checking the network connection
Article groups and serial number
Combined entrence with article groups
Variable sequence in one field
User Manual ATS400 Version 3.14.41 - 1
2
Contents
Polarity for protective conducter
Key words of the test step parameters
Key words of the Protective earth test type
User Manual ATS400 Version 3.14.41 - 1
3
Contents
Key words of the High Voltage AC test type
Key words of the High voltage DC test type
Key words of the Insulation test type
Key words of the FCT-Current test type
Key words of the Leakage current test type
Key words of the Sight check test type
Key words of the Data input test type
Key words of the Batch run test type
Key words of the User-Interface test type
Key words of the Resistance test type
Key words of the Continuity test type
Key words of the PT100 test type
Key words of the Lightcontrol test type
Key words of the Dummy load test type
Key words of the Light Filament current test type
Key words of the External programm test type
Key words of the test step measurement values
Key words of the multiple test values test step
Key words of the test step advices
Key words of the test step process control
Creation with Microsoft Word 2012
Creation with Microsoft Excel 2010
Error messages for high voltage AC
Error messages for high voltage DC
User Manual ATS400 Version 3.14.41 - 1
4
Contents
User Manual ATS400 Version 3.14.41 - 1 5
Introduction
1 Introduction
This manual describes the functions of
ETL DataView 3
.
This manual is aimed at various roles, which use
ETL DataView 3
. This manual differentiates between the roles of
,
. Furthermore, the manual contains a
about the tests, for the files used and created by
ETL DataView 3
.
Note
This manual has the status in progress. All details are correct to the best of knowledge, but may be incomplete. The information in this manual supplements and replaces the existing documentation.
All text in
Courier New blue
is either text as shown in the user interface or keywords in files.
Note
This manual is aimed to be used with an ATS400. When using devices of
Series 36 not all chapters are applicapable. There will be no note on this fact.
User Manual ATS400 Version 3.14.41 - 1 6
Administration
2 Administration
This part of the manual is aimed at system administrators.
It describes information that is necessary to set up and operate
ETL DataView 3
.
It describes activities that a system administrator must carry out if he wants to install
ETL DataView 3
on his own PC.
All instructions and screenshots refer to the operating system
Windows 7 SP1 32 bit
English.
Section you will only need if you are installing
ETL DataView 3
on your own computer:
You must also consider all other sections when changing the system environment, e.g.
want to integrate the
ATS400
in a network environment.
2.1
System setup
In this chapter the work is described which must be done by a
Windows
system administrator.
2.1.1
Windows users
On the variants X4 and X5 of the
ATS400
no users can be created on system level since Windows CE does not have users.
On the variants X6 and X8 of the
ATS400
one user with the name
ATS400
is created as adminstrator. This user has no password and is logged on automatically.
You can make the
ATS400
part of a domain and allow to log in with domain accounts.
You need additional users only when making the
ATS400
part of a network and the logged in user will use windows explorer or other applications using the network.
ETL DataView 3
will not make use of Windows users and does not support single sign on.
Important
If reports will be created and you will use multiple printers, e. g. for local printing and creating a PDF-file, the logged in user must have local adminstrative rights.
For each user logged into Windows the configuration of the PDF-Creator must be applied again, see
User Manual ATS400 Version 3.14.41 - 1 7
Administration
In chapter
Create network drive is described how to use a
ATS400
without adding to a domain to use test plans and store results in a network.
2.1.2
Installing ETL DataView 3
For the here describes installation of
ETL DataView 3
into the programs folder the following conditions must be met:
You must have local adminstration rights.
You must have
ETL DataView 3
on an data storage.
You must have aknowledgement of using
Windows Explorer
.
On a
Windows 7 64Bit
system the programs folder is named
Program Files (X86)
instead of
Program Files
.
Dependend on the settings of the User Account Control additional dialogs may be opened. These are not displayed in the following instruction. Additionally some buttons may be overlayed by the administrator symbol.
Create a new folder
ETL
in the programs folder of the PC.
User Manual ATS400 Version 3.14.41 - 1 8
Administration
Open using the contex menu the dialog
Properties
and step to the property page
Security
. Click on the button
Edit...
.
Click in the following dialog on the button
Add...
.
User Manual ATS400 Version 3.14.41 - 1 9
Administration
Enter
Everyone
and close the dialog with the button
OK
.
Activate for
Everyone
the checkbox
Full control
in column
Allow
.
Close both dialogs with the button
OK
.
User Manual ATS400 Version 3.14.41 - 1 10
Administration
Navigate to the folder
ETL
and create a new folder
DataView 3
.
Copy the files for
ETL DataView 3
from your data storage to
DataView 3
.
User Manual ATS400 Version 3.14.41 - 1 11
Administration
This folder should now contain the files like in the following screenshot.
User Manual ATS400 Version 3.14.41 - 1 12
Administration
Create a shortcut for
ETL DataView 3
.
Rename the shortcut into
ETL DataView 3
.
Allow
Windows Explorer
to show hidden files and folders. Open under
Organize
the
Folder and Searchoptions
. Step to property page
View
.
User Manual ATS400 Version 3.14.41 - 1 13
Administration
Activate the radio button
Show hidden files, folders and drives
. Close the dialog with the button
OK
.
To offer a start from the desktop copy the shortcut to the folder
C:
->
Users
->
Public
->
Public Desktop
.
To enable a start when a user logs in copy the shortcut to the folder
C:
->
ProgramData
->
Microsoft
->
Windows
->
Start Menu
->
Programs
->
Startup
.
Important
Before using
ETL DataView 3
you must configure the
User Manual ATS400 Version 3.14.41 - 1 14
Administration
2.1.3
Installing the PDF creator
ETL Prüftechnik
uses the PDF creator in version 1.6.2 to create PDF documents.
The PDF creator is already installed on the ATS400 variants X6 and X8. For the
ATS400 variants X4 and X5, it is not possible to install the PDF creator.
You only need to carry out the activities in this section if you are installing
ETL DataView 3
on your own PC and want to use the creation of PDF files as the report option.
Download the PDF creator from the site ftp://ETL-FTP:[email protected]/
Tools/PDFCreator-1_6_2_setup.exe
.
Copy the downloaded setup program to the computer to be used. To this end, we recommend using the
C:\Setups
folder. If the device is connected to a company network, please disconnect the network connection by removing the cable. This means that you will not need to reply to additional dialogues, and no further unnecessary components will be installed.
Start the setup by right clicking on the file and selecting
Run as an administrator
.
Then follow the standard setup. Part of the dialogues are not displayed if the computer is not connected to a network.
2.1.4
Setting up the PDF creator
To automatically save the PDF files, the PDF creator needs to be set up accordingly. A corresponding printer profile is created.
Important
For every user logged into
Windows
, this setup will partly have to be made separately.
User Manual ATS400 Version 3.14.41 - 1 15
Administration
Start the setup by right clicking on the desktop on the PDF creator icon. Select
Run as an administrator
from the menu.
Select
Printer
->
Options
from the menu.
User Manual ATS400 Version 3.14.41 - 1 16
Administration
Create a new profile by clicking on the button with the
plus symbol
.
A window
Profile
opens, enter
ETL
and confirm with
Ok
.
User Manual ATS400 Version 3.14.41 - 1 17
Administration
In the list box, in addition to
Standard
,
ETL
is now also included as a profile. Select
ETL
to change the settings.
For the
ETL DataView 3
to automatically create PDF files, the
Auto-save
tab needs to be saved. The file name and the directory must be stated precisely in doing so.
User Manual ATS400 Version 3.14.41 - 1 18
Administration
Activate the
Use 'Auto-save'
checkbox.
Enter the
etl_dataview
value in the
Filename
field.
Activate the
Use this directory for auto-save
checkbox. Select the
C:\Program
Files\ETL\DataView 3\Printing
folder in the relevant field.
End the dialogue with the
Save
button. The window will close.
User Manual ATS400 Version 3.14.41 - 1 19
Administration
Select from the
Printer
->
Printers
menu.
In the
New printer name
field, enter
ETLPrinter
and confirm the
Add printer
button. If the
Add printer
button cannot be selected, the setup program was not started with administrator rights.
User Manual ATS400 Version 3.14.41 - 1 20
Administration
Change the profile of the ETLPrinter to
ETL
.
End the dialogue with the
Save
button.
2.1.5
Adding to a network
ETL DataView 3
is able to store test plans and result files in a mapped network drive.
You can use one share to store all files or two separate shares for test plans and result files. You can use different hosts for test plans and result files. Preparing you need the following details:
When using a fixed IP address:
- IP address of the DNS server, z. B. 10.2.1.50
- IP address of the locale system, z. B. 10.2.1.186
- Subnetmask of the network, z. B. 255.255.255.0
In all cases:
- Name of the host, e. g. etldats
- Name of the share for the test plans, e. g. etl_nobackup
- Name of the share for the result files, e. g. etl_nobackup
- Name of the domain, e. g. etl.local
- Name of the user with sufficent rights for the share
- Password of the user with sufficent rights for the share
To do the work you need a USB-keyboard an propably a mouse. Be aware that on the variants X4 and X5 you can use only the left USB connector of the system. To
User Manual ATS400 Version 3.14.41 - 1 21
Administration
connect more than one device you also need an USB-hub.
With the variants X4 or X5 the
ETL DataView 3
.
With the variants X6 or X8 the integration can be done in
ETL DataView 3
. It is also possilble to do the integration using a
2.1.5.1 Variants X6 or X8
2.1.5.1.1 Create network drive
It is not neccessary to integrate the
ATS400
into a domain to load test plans or store result files on to a network drive.
You must know the domain name, the share name, the user and the password.
If you want to use any drive letter you map it in
Windows Explorer
.
Select in the folder view the entry
Computer
and choose for the menu bar
Map network drive...
. Enter into the following dialog your connection an user data.
Activate the checkboxes like displayed.
User Manual ATS400 Version 3.14.41 - 1 22
Administration
Alternativelly you can map the drive using a batch file in the startup folder. This integration must be done by your system administrator.
You cannot setup this configuration in
ETL DataView 3
. You must apply this settings manually. In the following example it is assusmed that you will store the test plans on drive N:\ and the result files on drive M:\.
Check in
ETL DataView 3
that under
Settings
->
File storage
->
Results
->
Storage
the radio button
Local
is activated.
User Manual ATS400 Version 3.14.41 - 1 23
Administration
Navigate in
Windows Explorer
to the folder
C:\Program Files\ETL\DataView 3
.
Open the file
Settings.conf
with the Windows Notepad.
Open the file with a double click and select in the opening dialog
Select a program from a list of installed programs
and close it with the button
OK
.
In the next dialog choose
Notepad
and close the dialog with the button
OK
.
User Manual ATS400 Version 3.14.41 - 1 24
Administration
Windows Notepad will open. Find the line with the entry
strPath_Plans
.
User Manual ATS400 Version 3.14.41 - 1 25
Administration
Change the text
Plans\
into
N:\
. Be carefull not to forget the ending character
\
.
User Manual ATS400 Version 3.14.41 - 1 26
Administration
Find the line with the entry
strPath_Results
.
User Manual ATS400 Version 3.14.41 - 1 27
Administration
Change the text
Results\
into
M:\
. Be carefull not to forget the ending character
\
.
Save the file and close Notepad.
User Manual ATS400 Version 3.14.41 - 1 28
Administration
In
ETL DataView 3
the entries are now visible under
Settings
->
File storage
.
User Manual ATS400 Version 3.14.41 - 1 29
Administration
User Manual ATS400 Version 3.14.41 - 1 30
Administration
2.1.5.1.2 Setup a network printer
If you want to use a network printer you must setup the printer in Windows.
Open
Devices and Printers
from the start menu. Chose from the menu bar
Add a printer
. In the opening dialog choose
Add a network, wireless or Bluetooth printer
.
User Manual ATS400 Version 3.14.41 - 1 31
Administration
Now the avalable network printers are searched and will be displyed in a list box.
Choose the printer from the list box.
User Manual ATS400 Version 3.14.41 - 1 32
Administration
You will be asked to install a driver. Choose the corresponding driver.
User Manual ATS400 Version 3.14.41 - 1 33
Administration
After the installation of the printer driver you can enter a name for the printer.
User Manual ATS400 Version 3.14.41 - 1 34
Administration
Do not share the printer.
User Manual ATS400 Version 3.14.41 - 1 35
Administration
After that dialog the printer will be diplayed in the list of the local printers.
User Manual ATS400 Version 3.14.41 - 1 36
Administration
2.1.5.2 Variants X4 oder X5
2.1.5.2.1 Network setup
After powering on the system end
ETL DataView 3
using the buttons
Workstation
,
Exit Dataview
and close the opening dialog with
Yes
.
Chosse from start menu
Settings
->
Network and Dial-up Connections
.
User Manual ATS400 Version 3.14.41 - 1 37
Administration
Then chosse the network adapter and open it with a double click.
User Manual ATS400 Version 3.14.41 - 1 38
Administration
In the opening dialog enter the desired settings. On the property page
IP Address
you choose using a DHCP-server or a fix IP address.
User Manual ATS400 Version 3.14.41 - 1 39
Administration
If you are using a fix IP address you must supply the address of the name server on the property page
Name Servers
.
Close the dialog using button
OK
.
User Manual ATS400 Version 3.14.41 - 1 40
Administration
2.1.5.2.2 Checking the network connection
Next you will check if the host can be reached over the network. For that the
ATS400
must be connected with the network. You need to open a
Command Prompt
window.
User Manual ATS400 Version 3.14.41 - 1 41
Administration
In the opening windows enter ping <hostname>. Replace <hostname> with the name of the host you will connect, in the example etldats. If there is a connection the answer is like displyed below.
There are two errors which can occur.
First ping cannot resolve the name of the host. In this case you get a message that the host could not be reached.
Second there is no connection. In this case data pakets are lost. In both cases contact your network admninistrator.
Close the window entering Exit.
User Manual ATS400 Version 3.14.41 - 1 42
Administration
2.1.5.2.3 Saving the settings
The settings are not persistant and must be saved. Open the
Run…
dialog.
User Manual ATS400 Version 3.14.41 - 1 43
Administration
In
Run
dialog enter ndcucfg and press the Enter key.
User Manual ATS400 Version 3.14.41 - 1 44
Administration
A new window will open. Enter reg save into the window and press the Enter key.
Close the window entering quit.
2.1.5.2.4 Checking the share
The share can now be checked. You must open
Command Prompt
again as described above.
Enter into the window net use Plans \\<Hostname>\<share name>. Replace
<Hostname> with the name of the host, in the example etldats, and <Share name> with the share name for test plans in the example etl_nobackup.
User Manual ATS400 Version 3.14.41 - 1 45
Administration
User Manual ATS400 Version 3.14.41 - 1 46
Administration
The dialog with the account data for logon will be opened. Enter user name, password and domain.
User Manual ATS400 Version 3.14.41 - 1 47
Administration
Next you will be asked if you want the data to be stored. If you store the data you will never be asked again for the logon data.
User Manual ATS400 Version 3.14.41 - 1 48
Administration
The successfully mapping wil be displayed.
If you get the message
Command failed: status 53
the share can not be used.
Contact in this case your network administrator.
User Manual ATS400 Version 3.14.41 - 1 49
Administration
Delete the mapping with net use Plans /d.
Close the window with exit.
User Manual ATS400 Version 3.14.41 - 1 50
Administration
2.1.5.2.5 Configuration
So
ETL DataView 3
can connect with the host it needs the corresponding information.
Enter these in
Settings
->
File storage
in the property pages
Network
->
Shared folder
->
Result
rsp.
Test plan
.
After entering the data you can establish a connection clicking on button
Connect
. If the connection is successfull the text changes from
Not connected
to
Connected
.
User Manual ATS400 Version 3.14.41 - 1 51
Administration
You can check a succefull connection by opening
Windows Explorer
.
User Manual ATS400 Version 3.14.41 - 1 52
Administration
In
Windows Explorer
click on the icon
Network
. The mappe dfolders will be displayed.
2.2
Configuration
This chapter covers work to be done for configuring
ETL DataView 3
.
User Manual ATS400 Version 3.14.41 - 1 53
Administration
2.2.1
Setting up language
Open the dialog choosing
Settings
->
Language
.
Select in the list the desired language. Click on button
OK
to apply the language. This setting will be stored in file
Settings.conf
. The language will be active immediately for most of the dialogs. The dialog will be closed and the window
Settings
will be displayed again.
With a click on the button
Menu
the change will be lost. The dialog will be closed and the window
Mainmenu
will be displayed again.
User Manual ATS400 Version 3.14.41 - 1 54
Administration
2.2.2
Naming the workstation
Open the dialog choosing
Settings
->
Workstation
->
Base settings
.
Click into the field right of
Name
. A keyboard window will be opened. Enter the name of the workstation. Click on one of the buttons
Back
or
Menu
. The settings will be stored in the file
Settings.conf
.
When
creating reports you can access the field with the keyword
2.2.3
Signal tones
Additional to the signal tones generated for the overall result also signal tones can be given for each test step. The duration of the tone is according to the setting for the overall result.
User Manual ATS400 Version 3.14.41 - 1 55
Administration
Open the dialog choosing
Settings
->
Workstation
->
Base settings
.
These setting is done by the 4 top checkboxes. Click on one of the buttons
Back
or
Menu
. The settings will be stored in the file
Settings.conf
.
Selection
Buzzer Individual test IO
Buzzer Individual test NIO
Buzzer Multi testIO
Buzzer Multi test NIO
Behaviour
Is the result of a test step IO a signal tone is generated. This is independent from the fact of the test step is part of a multi test step or not.
Is the result of a test step NIO a signal tone is generated. This is independent from the fact of the test step is part of a multi test step or not.
Is the result of a test step IO a signal tone is generated. This is done only when the test step is part of a multi test step.
Is the result of a test step NIO a signal tone is generated. This is done only when the test step is part of a multi test step.
User Manual ATS400 Version 3.14.41 - 1 56
Administration
2.2.4
Safety cabinet
When using a safety cabinet you can choose several settings. To use this settings it is neccessary to use a safety cabinet support the signals
IN OP
and
Locking
on the
ETL-Interfaces
of the
ATS400
.
This setting applies to the workstation and is valid for all test plans.
Open the dialog choosing
Settings
->
Workstation
->
Base settings
.
Choose a value from the list
Safety cabinet
. This will change the behaviour of the signal
Out 6
on the
ETL-Interface
. Click on one of the buttons
Back
or
Menu
. The settings will be stored in the file
Settings.conf
.
Selection
No cabinet
Locked during plan
Behaviour
The signal has the meaning
READY FOR
OPERATION
and behaves as described in the base device manual in chapter
ETL-
Interface for Selection and
Operation Panels
.
The signal has the meaning
Locking
. The safety cabinet will not open as long as a
User Manual ATS400 Version 3.14.41 - 1 57
Administration
Selection
Unlock on pass
Behaviour
test is running. After the test the safety cabinet can be opened independent from the overall result of the test.
The signal has the meaning
Locking
. The safety cabinet can not be opened as long as the overall result is not passed. Will the safety cabinet stay locked a message is displayed. You can unlock the safety cabinet with a button on the screen or the signal
Button Stop
on the
ETL-
Interface
.
2.2.5
Startmode
You can define which window will be displayed after starting
ETL DataView 3
.
Open the dialog choosing
Settings
->
Worksation
->
Startmode
.
Dependend from the selection in
Startup mode
additional controls may be displayed.
These are labeld as
Individual Test
or as
Plan
.
User Manual ATS400 Version 3.14.41 - 1 58
Administration
Selection
Main menu
Select plan by ID
Start in batch mode
Select plan manually
Individual test
Menu individual test
Plan
Behaviour
The main menu will be displayed.
The window
Select ID
will be displayed.
The window
Test batch
will be displayed.
The window
Select manual
will be displayed.
Additionally the selection
Individual
Test
will be displayed. You can select which test type will be started. You can only select enabled test types. The test will be started immediatelly after the start.
The window
Test individual
will be displayed.
Additionally the selection
Plan
will be displayed. You can select one of the test plans. This test plan will be running immediatelly after the start. Will the test plan be renamed or deleted you get a message and the main menu will be displayed.
Important
Having
user administration active all user should have the right to use the
window configured as start up window.
User Manual ATS400 Version 3.14.41 - 1 59
Administration
2.2.6
Test plan selection
You can determine how to enter data during automatic test plan selection.
Open the dialog choosing
Settings
->
Workstation
->
Program select
.
Dependend from the selection in
Select plan
are the controls operational.
With the drop down box
Select plan
you can choose from which source the selection will be taken.
Choosing
ETL-Interface
the test plan will be selected by applying a number at the
ETL-Interface and active the acquisition. Details are described in the base device manual.
Choosing
Keyboard
a window will be displayed. Into this window a ID will be entered which is used to select the test plan.
Choosing
File Plan.ID
a file with the name
Plan.ID
must be created in the plans folder. This file contains a line with the ID which is used to select a test plan. Optional in a second line a serial number and in a third line a article description can be given.
The contents of the file will be periodically checked.
Using this selection the checkbox
Delete Plan.ID
is operational. Is this check box active the file will be deleted after it has been processed.
User Manual ATS400 Version 3.14.41 - 1 60
Administration
The fields
Typ-Pattern
,
ID-Pattern
,
Serial-Pattern
and
Article-Pattern
as well as the corresponding check boxes are operational if
Keyboard
is selected in
Select plan
. With the other selections the controls are disabled.
In the field
Typ-Pattern
is the pattern which is used to test the entered data using automatic test plan selection. This pattern must be meet to have a valid entered data. The entered data will be in the result file as tag
TYPE
.
The check box
Combibox
indicates that the field
Typ-Pattern
contains two parts.
When
Combibox
is active the fields
ID-Pattern
and
Serial-Pattern
are getting operational, the check boxes
Enable
will both be activated and disabled.
In the field
ID-Pattern
is the pattern which will be used to extract the type from the entered data. The extracted value will be in the result file as tag
USEDID
.
The corresponding check box
Enabled
indicates that the entrance contains a type.
In the field
Serial-Pattern
is the pattern which will be used to extract a serial number. The extracted value will be in the result file as tag
SERIALNUMBER
.
The corresponding check box
Enabled
indicates that the entrance contains a serial number.
In the field
Article-Pattern
is the pattern which will be used to extract additional article data. The extracted value will be in the result file as tag
ARTICLE
.
The corresponding check box
Enabled
indicates that the entrance contains additonal article data.
Details how to enter pattern are in topic
2.2.6.1 Examples
The following examples shows possible settings at hand of the number scheme used by
ETL
. This scheme consist of a article number with 6 ciphers followed by a blank and the serial number. The serial number consists of 4 ciphers for the production month a blank and 4 ciphers for a number. This leads to following pattern:
000000\ 0000\ 0000
An example number is 205589 0515 1000. The corresponding aricle description is UGP-
5025.
Other examples will show additional possibilities.
User Manual ATS400 Version 3.14.41 - 1 61
Administration
2.2.6.1.1 Article number
Should for automatic test plan selection only the article number be used the pattern has to be given in field
Typ-Pattern
. The check boxes remain inactive and the other fields remain empty.
User Manual ATS400 Version 3.14.41 - 1 62
Administration
2.2.6.1.2 Article groups
Should for automatic test plan selection only the article number be used the pattern has to be given in field
Typ-Pattern
. The check boxes remain inactive and the other fields remain empty. The pattern must be entered that the characters for the group are included in paranthesis. In the test plan only the article group ist entered for the identification.
User Manual ATS400 Version 3.14.41 - 1 63
Administration
2.2.6.1.3 Article- and serial number
Should for automatic test plan selection the article number and the serial number in sepearate fields be entered both check boxes for
ID-Pattern
and
Serial-Pattern
must be activated. In the fields
Typ-Pattern
and
Serial-Pattern
the patterns are entered. There is no need to enter something in
ID-Pattern
because this pattern is identical with the pattern in
Typ-Pattern
. The check box
Combibox
remains inactive.
User Manual ATS400 Version 3.14.41 - 1 64
Administration
2.2.6.1.4 Article groups and serial number
Should for automatic test plan selection the article number and the serial number in sepearate fields be entered both check boxes for
ID-Pattern
and
Serial-Pattern
must be activated. In the fields
Typ-Pattern
and
Serial-Pattern
the patterns are entered. The pattern must be entered that the characters for the group are included in paranthesis. In the test plan only the article group ist entered for the identification.
There is no need to enter something in
ID-Pattern
because this pattern is identical with the pattern in
Typ-Pattern
. The check box
Combibox
remains inactive.
User Manual ATS400 Version 3.14.41 - 1 65
Administration
2.2.6.1.5 Combined entrance
Should for automatic test plan selection the article number and the serial number in a common field be entered the check box
Combibox
has to be activated and in all fields an entry has to be made for the patterns. The pattern in field
Typ-Pattern
must be entered that the characters for the article number are include in paranthesis. The sequence of the fields is fixed first the article number and then the serial number. The setting look like shown below.
User Manual ATS400 Version 3.14.41 - 1 66
Administration
2.2.6.1.6 Combined entrence with article groups
Should for automatic test plan selection the article number and the serial number in a common field be entered the check box
Combibox
has to be activated and in all fields an entry has to be made for the patterns. The pattern in field
Typ-Pattern
must be entered that the characters for the group are included in paranthesis. The sequence of the fields is fixed first the article number and then the serial number. The setting looks like shown below.
User Manual ATS400 Version 3.14.41 - 1 67
Administration
2.2.6.1.7 Variable sequence in one field
Is the sequence of the fields undetermined so the fields must be separated by a character. The pattern for the type and the serial number must be different.
Otherwise the fields cannot be separated. In this case the setting looks like shown below.
User Manual ATS400 Version 3.14.41 - 1 68
Administration
2.2.7
Dummy test
These settings must be done if you want to check the
ATS400
and the test station for functionality.
Open the Dialog using
Settings
->
Workstation
->
Dummy
.
Parameter
Program Start
User Change
Count
Interval
Time
Description
The dummy test will be done when the program starts.
The dummy test will be done after a user logs in.
The dummy test will be done after the given number of tests. When opening a test plan or changing it the counter will be reset to 0.
Time interval between two dummy tests. Checking for the end of the interval will be done when waiting for the start condition of the test step or when waiting for the identification of the unit under test. The intervall starts after a successfull dummy test.
Up to 5 points in time can be defined when a dummy test will be performed. Checking for the time will be done when
User Manual ATS400 Version 3.14.41 - 1 69
Administration
Parameter
Automatical dummy
Description
waiting for the start condition of the test step or when waiting for the identification of the unit under test. The times will be repeated for each day.
This checkbox must be set when an automatic dummy will be used.
Any combination can be configured despite of such a setting makes sense.
Important
The name of the result file and the report files are according to the same rules as with normal test plans.
Will in the file name not choose to use DateTime only the last dummy test will be recorded. Will the dummy test be executed after a certain amount of tests the result file and the report of the last test will be overwritten.
Will by creating the folder name a preset keyword or a keyword from the test type Data input be used invalid folder names may arise when they should be stored in subfolders.
Will
Program Start
be used together with
Time
the following rule applies:
The dummy test of the next point in time in the future will not be executed.
Example:
The points in time 8:00 and 16:00 are configured. The successfull dummy test when starting the program was at 7:55. Therefore the dummy test at 8:00 will not be executed. The next dummy test will be at 16:00.
Will
Program Start
be used together with
User Change
then after the start of the program and loging in of the user the dummy test will be executed only once.
Following settings are recommended if no other rules apply:
Scenario
Laboratory use or single shift
Device will be powerd off.
Two shifts without user administration
Device will be powerd off
Multiple shifts with user administration
Setting
Select
Programm Start
.
Select begin.
Select
Program Start
User Change
.
and two times when the shifts
User Manual ATS400 Version 3.14.41 - 1 70
Administration
Scenario
Different Windows user
Setting
Select
Programm Start
.
2.2.8
User administration
With the user administration you can limit the possibilities of the users in
ETL DataView 3
.
Open the dialog choosing
Settings
->
User administration
.
The check box
User administration
determins if you have user administration active. Is the check box active user administration is also active.
The check box
Enable anonymous user
determins if a user must log in. Is this check box active this user will be logged in automatically.
ETL DataView 3
has two user as default which cannot be deleted.
First this is ADMIN, who holds all rights as default. This user is provided to get access to the system without help from
ETL Prüftechnik
in the case the password has been forgotten. This user cannot be deleted. The factory default password for ADMIN is
ETL. This can be changed but it is recommended to keep it.
User Manual ATS400 Version 3.14.41 - 1 71
Administration
Second this is Anonymous which allows to log in without displaying a login dialog. The factory default is that this user has no rights.
Important
As factory default the anonymous user has no rights. He cannot run a test, make settings or exit
ETL DataView 3
. This should be taken into consideration when choosing the
.
2.2.8.1 Add an new user
Click on the button
New
to create an new user.
A new windows is opened to enter the user name. leaving with
OK
the user will be created and he will be added to the list.
The user name and the password are case sensitive.
2.2.8.2 Enter password
Select the user in the list and click on the button
Password
to add or change the password.
The user name and the password are case sensitive.
The password is encrypted an cannot be restored.
2.2.8.3 Delete user
Select the user in the list. Click on the button
Delete
. A confirmation dialog is displayed. If you confirm the user will be deleted.
2.2.8.4 Assign rights
Select the user in the list. Activate or unactivate the check boxes on the right side to allow or deny the desired rights.
Important
Be carefull to give all users the right to use the window defined in
User Manual ATS400 Version 3.14.41 - 1 72
Administration
2.2.8.5 Automatic logout
Open the dialog with the button
Autologout
.
In this dialog the rules are configured a user will be logged out automatically.
Selection
Time
Menu
Plan select
Start condition
Behaviour
Determines the time interval the user is logged off.
The time intervall is active when the user is in a menu window. All menus and windows reached via button
Settings
are not considered.
The time intervalis active when the user is in a window for test plan selection.
The time intervall is active when waiting to read the start conditions of the first step in a running test plan.
User Manual ATS400 Version 3.14.41 - 1 73
Administration
2.2.9
File storage
In this menu you can setup additonal to the storage places for
and
network settings . Furthermore
temporary options for storage of result
files experiencing problems with the storage media and
internal storage media.
Open the dialog choosing
Settings
->
File storage
.
2.2.9.1 Result files
On the property page
Result
you can define in which cases result files will be stored and on which media.
In the upper part of the property page
Storage
you can select in which cases result files will be stored. There are three possibilities and you can choose one or multiple of them.
With
Test IO
result files will be stored in the case the overall result is passed.
With
Test NIO
result files will be stored in the case the overall result is failed.
User Manual ATS400 Version 3.14.41 - 1 74
Administration
Wiht
Not tested (Error)
result files will be stored in the case the test was aborted by the user or by a problem arising from the system, e. g. overtemperature.
In the lower part of the property page
Storage
you can select the media to store the files on. Selecting
Local
the media of the system will be used. With variants X4 and
X5 this is the buildt in SD-Card and with variants X6 and X8 this is the internal hard disk.
On the property
Path
you can define the naming of a folder for the result files and the report files.
On the property page
Path
you can make additional settings for the folder where result files and report files are stored. If you select
_NONE
in all fields no subfolder is created.
You can select from the keywords
PlanName
,
PlanID
,
Workstation
,
Type
,
UsedID
,
SerialNumber
and
Article
.
PlanID
is the identifikation of the test plan and
PlanName
the name of the test plan.
Workstation
is the
.
Type
,
UsedID
,
SerialNumber
and
Article
result from the automatic plan selection.
The checkbox
Create Subdirs
determins how the fields are used. Is the checkbox inactive one subfolder will be created where its name is concatenated from the
User Manual ATS400 Version 3.14.41 - 1 75
Administration
diferrent fields. Is the checkbox active for each field a new subfolder is created in a hierarchical manner.
The combined path is displayed in the text field at the bottom.
On the Property page
Filename
you can define the name of the result file and report file.
The above dispayed setting is factory default. The combined file name is displayed in the text field at the bottom.
User Manual ATS400 Version 3.14.41 - 1 76
Administration
2.2.9.2 Test plans
You can select the storage of the test plans.
On the property page
Test Plan
you can select the storage media. You can select from one of the medias
Local
,
USB
or
LAN
.
Is the checkbox
Save after Execution
active the test plan will also be stored after executing a test. This will preserve data entered by the tester as default when using the test plan again.
User Manual ATS400 Version 3.14.41 - 1 77
Administration
2.2.9.3 Network
On the property page
Network
you must make the settings when chossing
LAN
for result files or test plans. The settings have to be made in similar way for result files and test plans.
Refer to the chapters in
Adding to a network on how to use this dialog.
User Manual ATS400 Version 3.14.41 - 1 78
Administration
2.2.9.4 Temporary files
On the property page
Temp
you define when temporary stored result files and report files will be moved to their original destination folder.
This setting is only valid whe the storage media is set to
USB
or
LAN
. In this case there is the possibility that the storage media is not available when storing result files or report files. In this case the files will be stored locally. These files will be moved in the case the storage media is available again. Since there is the possibility that a larger amount of data must be moved and you cannot test during that activity you can define when and how much files will be moved. Factory default is
If destination available
.
With
If destination available
the files will be moved after the next test.
With
On exit testplan
the files will be moved the test plan will be exited.
With
On startup only (All files)
all files will be moved when
ETL DataView 3
is starting.
The radio button below
Files to move
are only valid when
If destination available
or
On exit testplan
is selected.
You can define that all files or a limited number of files should be moved.
User Manual ATS400 Version 3.14.41 - 1 79
Administration
2.2.9.5 Tool
On the property page
Tool
you can permanently delete files. There will be no confirmation dialog.
With the button
Delete Results
the localy stored result files and report files will be deleted.
With the button
Delete Temp Results
the temporary stored result files and report files will be deleted.
With the button
Delete Individual Tests
the settings for the single step test will be reset to factory default.
2.2.10 Serial interface
For
ETL Dataview 3
can connect to the device the serial interface must be configured. You must do this only when installing
ETL Dataview 3
on your own system.
User Manual ATS400 Version 3.14.41 - 1 80
Administration
Important
With the variants
ATS400
X8 and X6 the serial interface is set to COM2 as factory default. With the variants
ATS400
X5 and X4 the serial interface cannot be configured.
Open the dialog choosing
Settings
->
Workstation
->
COM
.
All available serial interfaces on the system will be displayed. Choose those interface the
ATS400
is connected with.
After clicking on the button
Connect
the serial interface will be opened and tried to connect to the device. Is a connectin established the LED
Remote
at the front of the
ATS400
is on.
Close the dialog with the button
Back
and exit
ETL DataView 3
.
User Manual ATS400 Version 3.14.41 - 1 81
Administration
2.2.11 Push button
Using a second front together with variant X2 it is nesseccary to deactivate the push button on the front.
Open the dialog choosing
Settings
->
Workstation
->
Base settings
.
Is the checkbox
Wheel
active the push button can be used. This setting is stored in the file
Settings.conf
.
User Manual ATS400 Version 3.14.41 - 1 82
Administration
2.2.12 Change voltage
There is the possibility to change the voltage of a high voltage test during the test using the push button. This possibility must be activated.
Open the dialog choosing
Settings
->
Workstation
->
Base settings
.
Is the checkbox
Change voltage
active you can use the push button to change the voltage during a test. This setting is stored in the file
Settings.conf
.
2.2.13 Dummy test plan
The dummy test plan is created by ETL Prüftechnik and will be delivered with the dummy. You can use only one dummy test plan. The dummy test plan is stored in the subfolder
DummyPlan
of the
ETL DataView 3
folder. There must only one file with the extention
.plan
in this folder.
The dummy test plan will be used as a normal test plan. A result file will be created according to the settings in
Settings
->
File Storage
.
As factory default a dummy test plan doesn't create a report file.
The execution of the dummy test plan is done manually or according to the settings in
User Manual ATS400 Version 3.14.41 - 1 83
Administration
Caution
The following procedure is not covered by any rights within
ETL DataView 3
.
The work described here can be done by any user having the right to change test plans.
Important
The name of the result file and the report files are according to the same rules as with normal test plans.
Will in the file name not choose to use DateTime only the last dummy test will be recorded. Will the dummy test be executed after a certain amount of tests the result file and the report of the last test will be overwritten.
Will by creating the folder name a preset keyword or a keyword from the test type Data input be used invalid folder names may arise when they should be stored in subfolders.
Exit a running
ETL DataView 3
.
Copy the dummy test plan for Subfolder
DummyPlan
into the folder where your test plans are located.Be carefull not to overwrite an existing test plan.
User Manual ATS400 Version 3.14.41 - 1 84
Administration
Navigate in Windows Explorer to the folder
C:\Programm files\ETL\DataView 3
.
Open the file
Settings.conf
with the Windows Editor.
Open the file with a double click and select in the opening dialog
Select a program from a list of installed programs
and close it with the button
OK
.
In the next dialog choose
Notepad
and close the dialog with the button
OK
.
User Manual ATS400 Version 3.14.41 - 1 85
Administration
Windows Notepad will open. Find the line with the entry
Edit_Invalid_Enabled
.
User Manual ATS400 Version 3.14.41 - 1 86
Administration
Change the value from
false
into
true
.
Save the file and close the editor.
Start
ETL DataView 3
again.
Change the dummy test plan by adding the desired report options. Exit
ETL DataView 3
again.
Change in the subfolder
DummyPlan
the extension of the file from
.plan
into
.plan$
.
Move the dummy test plan from the folder with your test plans into the subfolder
DummyPlan
.
Change the value in
Edit_Invalid_Enabled
in the file
Settings.conf
from
true
to
false
.
2.2.14 Printserver configuration
For configuring the print server the
configuration file must be present. You can
configure that the files from the report creation will be stored in a different location as the result files, the behaviour how to deal with unknown keywords in the report und the timeout for waiting on PDF-reports or printing.
User Manual ATS400 Version 3.14.41 - 1 87
Administration
Important
In the case the configured folder is on an external storage media, e. g. a memory stick or network, this media must be present before the first report will be created. The tester will see a runtime message and the file will not be stored.
This settings must be made manually and are not supported by
ETL DataView 3
.
Exit
ETL DataView 3
. The configuration will only be read during startup.
Navigate in Windows Explorer to the folder
C:\Programm Files\ETL\DataView 3
.
Open the file
Printserver.conf
with Notepad.
Open the file with a double click and select in the opening dialog
Select a program from a list of installed programs
and close it with the button
OK
.
User Manual ATS400 Version 3.14.41 - 1 88
Administration
In the next dialog choose
Notepad
and close the dialog with the button
OK
.
For configuring an alternative folder you must change the entry for the report type.
The file contains for each report type an empty element. You must create an opening and closing element.
Add a folder name or change an existing folder name. In this example for the report type
to folder
N:\
.
To change the timeout for the report file you must change one of the existing numbers. Be aware that the time is in milliseconds.
With the element
Debug
the output can be changed if an unknown keyword is found.
The element
PdfTimeout
is a time within the PDF-file must be created. Is the file created before this time is elasped the next report can be created.
The element
PrintTimeout
is a wait time. The complete time will be waited before the next report can be created.
Save the file and close Notepad. Start
ETL DataView 3
again.
User Manual ATS400 Version 3.14.41 - 1 89
Test plan editing
3 Test plan editing
This part of the manual is aimed at the persons who create and edit the test plans.
It contains all information that is necessary to create the test plans in accordance with the requirements for the test and the existing test types.
All illustrations and options refer to the Windows variant that you receive with the
ATS400
variants X2, X6 and X8. The Windows CE variants with the
ATS400
variants
X4 and X5 do not contain all options.
3.1
Administering test plans
Open the dialog choosing
Test plan
->
Create / Edit
.
On the left side a list of the currently available test plans is displayed.
In the midth upper part the test steps in the selected test plan are displayed. Is no test plan selected the list is empty.
In the midth lower part the data for the test step is displayed. Is no test plan or no test step selected the list is empty.
User Manual ATS400 Version 3.14.41 - 1 90
Test plan editing
Button
Change plan
New Plan
Copy plan
Delete plan
Plan information
Test
Back
Action
The window for
be displayed and the selected test plan can be changed.
A new plan will be created. Details for this you will find in the quick start guide.
The selected test plan will be copied. You must enter a new name.
After a confirmation dialog the test plan will be deleted permanently if you confirm this.
The window for
opened.
In this mode no changes can be made.
The window
Test plan
will be opened.
The window will be closed.
User Manual ATS400 Version 3.14.41 - 1 91
Test plan editing
3.2
Changing test plans
Open the dialog choosing
Test plan
->
Create / Edit
->
Change plan
.
On the left side a list with the currently present test steps is displayed. The test steps can be expanded or collapsed.
Button
Edit
Add
Delete
Copy
Action
This button is available in the case a test step is selected.
The window for configuring the test step will be displayed.
A new test step will be created. Details can be found in the quick start guide.
This button is available in the case a test step is selected.
After a confirmation dialog the test step will be deleted permanently.
This button is available in the case a test step is selected.
The test step will be copyed to the
User Manual ATS400 Version 3.14.41 - 1 92
Test plan editing
Button
3.3
Cut
Paste
Up down
Expand
Collapse
Test
Close
Plan Options
Action
internal clip board.
This button is available in the case a test step is selected.
After a confirmation dialog the test step will be copied to the internal clip board and then will be deleted permanently.
This button is available when a test step is present in the internal clip board.
This test step will be inserted below the seleted test step.
targets of existing test steps will be adapted automatically. The
inserted test step will be set to default values.
This button is available in the case a test step is selected.
The selected test step will be moved one position upwards.
adapted automatically.
This button is available in the case a test step is selected.
The selected test step will be moved one position downwards.
targets will be adapted automatically.
All test steps of the test plan will be expanded. The text changes to
Collapse
.
All test steps of the test plan will be collapsed. The text changes to
Expand
.
The window
Test
will be opened.
The window will be closed.
The window for
opened.
In this mode changes can be done.
Test types
For each test type exists specific parameters and common parameters. The specific parameters are unique for each test type and the common parameters are the same for all test types. Not all common parmeters are present for every test type and may not be present when configuring a single test step.
Common parameters are:
User Manual ATS400 Version 3.14.41 - 1 93
Test plan editing
3.3.1
Common dialogs
3.3.1.1 Ramp
The ramp configuration describes the ramp parameters.
Factroy default is that no ramp is used.
Ramp
: Turns the ramp on and off. The other parameters can be changed when ramp is turned on.
Start
: Voltage with that the ramp will start.
Up
: Time in seconds from the start voltage up to the test voltage.
Test
: Test time in seconds. This is the time the test voltage is applied to the unit under test. This is the same value a parameter
t
in the configuration dialog.
Down
: Time in seconds from the test voltage to the end voltage.
User Manual ATS400 Version 3.14.41 - 1 94
Test plan editing
3.3.1.2 Start conditions
The start conditions describe under which cirumstances the test will start.
Each signal can have one of four states.
Active
: The signal must be set to provide a start.
Not Active
: The signal must not be set to provide a start.
Ignore
: The signal will be ignored.
Monitored
: The signal must be set. It will be monitored that the signal will be set in the case all other signals with state
Active
are alredy set. Will the signal not be set within the configured time the test will be evaluated as failed and will be aborted. Are multiple signals with state
Monitored
the first signal reaching the time will fail and abort the test.
To select the state
Monitored
at least one other signal must have state
Active
.
Is there only one signal with state
Active
and no other signal has state
Monitored
, the state of that signal cannot be changed.
It is under the responsibility of the test plan editor to choose a combination that makes sense for his scenario.
The signal
Start-Button
allows the start with the
Starttaste
at the front or the signal
Button Start
on the ETL Interface or the
Start
button on the screen.
User Manual ATS400 Version 3.14.41 - 1 95
Test plan editing
The signal
PE-Testprobe
allows the start with the button at the PE-Testprobe.
The signal
Contact Monitoring
allows the start with contacting, e. g. with test pistols.
The singal
Safety Circuit HV
allows the start with closing the safety circuit. For the test type
HV-AC
this value is always
Active
and cannot be changed. For the test types
HV-DC
and
ISO
it depends from the settings in the
ATS400
. If the value can be changed. Factory default is the value
Active
and cannot be changed.
Statechange
requires that at least one of the signals with state
Active
or
Monitored
must change its state from not set to set to provide a start. When manually contacting the unit under test it ensures that the new test point has been contated.
This checkbox is not visible on single test and the first test step in a test plan and is always set.
Delay
will delay the start of the test after the start conditions are meet.
Repeating
allows to execute test steps only once, each time or nth time to execute.
Is the value 0 the test step will only be executed once. Is the value 1 it will be executed each time. For all other values the test step will be executed the first time and then be omited for n-1 times. This parameter will not be displayed for single test.
Buttons
is a combobox. You have four selections. This combobox is not visible for single test and set to
None
.
None
dosn't show any buttons.
Skip
allows the tester to omit the current test step. It will be evaluated as passed for the overall result.
Start
allows to start the test step.
Start and skip
shows the skip and the start button.
User Manual ATS400 Version 3.14.41 - 1 96
Test plan editing
3.3.1.3 Matrix
With this property page the settings of a matrix will be configured.
Shown is the dialog in the case a
configuration file is present.
Parameter
Off
Matrix ETL-
Interface
ETL-IO: Out 7
(Pin9)
ETL-IO: Out 8
(Pin10)
Matrix CAN
Description
Both outputs of the ETL-Interface are off and all relais of a matrix are in default position.
The ETL-Ingterface will be used. This setting is only possible if in
Settings
->
I/O-Interface
the check box
Disable SC, Con
is active.
This check box determines the state of the output Out7 of the ETL-Interface.
This check box determines the state of the output Out8 of the ETL-Interface.
This checkbox can be selected in the case a cofiguration file for a matrix is existent. If the checkbox is active the matrix can be configured.
On the sub property page
Relaismatrix
are controls to configure the matrix.
User Manual ATS400 Version 3.14.41 - 1 97
Test plan editing
Parameter
Bank
Reset
HV1
HV2
Description
With the buttons it can be switched between the banks of the different outputs. If there is a non default setting in a bank a yellow field will be displayed near the button.
Sets als outputs to the default setting.
If a button in this line is set the wire HV1 is switched to the coresponding output.
In this line the number of the outputs of the active bank are displayed.
If a button in this line is set the wire HV2 is switched to the coresponding output.
In the example above the output 1 is connected to wire HV1 and output 2 is connected to wire HV2.
3.3.1.4 Jump
On this property page jumps are configured.
User Manual ATS400 Version 3.14.41 - 1 98
Test plan editing
On the property page
Jump
conditions can be configured how the test plan will select the next test step. For the test steps can provide thre different results you have one property page for each different result. The settings are the same for each result.
On property page
IO.
you define the target if a test has ended with passed.
On property page
NIO
you define the target if a test has ended with failed.
On property page
Cancel
you define the target ist a test has been aborted.
You can select
Next
and the test plan will proceed with the next step.
You can select
End
and the test plan will end.
You can select
Jump
and you can select a test step in the drop down box. The stet plan will proceed with this test step.
3.3.1.5 Text
On this property page user advices are configured.
On the propety page
Text
an text or picture can been shown before, during or on an erroneous test.
User Manual ATS400 Version 3.14.41 - 1 99
Test plan editing
The text can be entered by a click on the white edit box and activated by setting the checkbox
Show
. The hight of the font can be changed in the drop down box.
Will an advice been shown
Before
it will be visible until the start conditions are meet.
Will an advice been shown
During
a test it will be visible until the test step ends.
Will an advice been shown on
Error
it will be visible until the dialog will be confirmed.
On
Cont. On Error
you can configure when the advice on
Error
will be confirmed.
You can use the same conditions as for start conditions.
On variant
ATS400 X4
there isn't the possibility to use pictures. The corresponding controls aren't visible.
3.3.1.6 Multitest
On this property page the multi test parameters are configured.
To summarize multiple test points into one result, e. g. the number of test points is different for different units under test, you can use
Multitest
.
User Manual ATS400 Version 3.14.41 - 1 100
Test plan editing
Parameter
Enable
Result
Show
Size
Text
Image
Search
Description
Enables multi test behaviour.
Configures how the results of the test are summarized.
Worstcase
: The worst measurement will be used.
Mode
Count
Configures the end of a multi test.
# of Measurements
: You must have the numer of tests with result passed as given in
Count
.
Button Pass
: The multi test ends when the pass button is pressed. It dosn't matter if this is coming from the front of the
ATS400
, the button on the screen or from the ETL-
Interface.
Configures how much tests must be done when used in mode
# of Measurements
. This parameter is only be visible when in
Mode
the value
# of Measurements
is selected.
Pass button visible
Configures to show the button
Pass
on the screen. This parameter is only be visible when in
Mode
the value
Button
Pass
is selected.
Configures that a user advice will be shown between two tests of a multi test.
Configures the hight of the font of the text of the user advice.
Text of the user advice.
The text will be shown as user advice.
A picture will be shown as user advice.
Shows the file select dialog to select the picture. This button is available when
Image
is selected.
On variant
ATS400 X4
there isn't the possibility to use pictures. The corresponding controls aren't visible.
User Manual ATS400 Version 3.14.41 - 1 101
Test plan editing
3.3.1.7 Create log
On this property page the logging is configured.
To log measurements during a test logging can be activated.
Parameter
Enable
Time interval
Description
Activates the logging.
Configures how often measurements are stored.
For each test step a file will be created. The rule for the base name is according to the result file. The number of the test step is added to the base name.
The file is a test file in csv-format and can be imported to other applications. The exact format depends on the test type.
User Manual ATS400 Version 3.14.41 - 1 102
Test plan editing
3.3.2
Protective Earth test
The protective earth test will be configured using the following dialog.
I
U
Parameter t
R max
Description
Test time in seconds. The test time is the time the current is flowing through the unit under test.
Test current in A. This current is flowing through the unit under test for the test time.
Open circuit voltage in Volt. This voltage is applied to the unit under test or the contacts in the case no current is flowing through the unit under test.
Maximum allowed resistance for evaluation.
User Manual ATS400 Version 3.14.41 - 1 103
Test plan editing
3.3.3
High voltage AC
The high voltage AC test will be configured using the following dialog.
Parameter t
U
I min
I max f
Result
Description
Test time in seconds. The test time is the time the testing voltage is applied to the unit under test. The times for powering on and off and the ramp times are not part of the test time.
Testing voltage in kilovolt. This voltage is applied to the unit under test for the test time.
Minimum test current. This current must be flowing through the unit under test during the test time. If the current fallse below this limit the test is evaluated as not ok.
Maximum test current. The current must not exceed this limit during the test time. If the current exceeds this limit the test will be evaluated as not ok.
Frequency in Hertz. Frequency of the testing voltage.
You can select how the evaluation is done. Selecting
Test
User Manual ATS400 Version 3.14.41 - 1 104
Test plan editing
Parameter
Sparc detection
Description
Time
the test ends after the test time. Selecting
Start-
Button
the evaluation ends with pressing the start button again.
This parameter will only be visible when the
ATS400
is supporting this function.
You can select if spark detection is disabled resp. how sensitive it is. Spark detection evaluates the break down of the measured voltage regarding to size and gradient.
Selecting
Off
spark detection is disabled. Selecting
Coarse
a large spark will be detected, selecting
Normal
the sensitivity is medium and selecting
Fine
small sparks will be detected.
Additional informations about the behaviour of the high voltage test, the error messages and the evaluation you will find in the
.
3.3.4
High voltage DC
The high voltage DC test will be configured using the following dialog.
User Manual ATS400 Version 3.14.41 - 1 105
Test plan editing
Parameter t
U
I min
I max
Result
U Discharge
Sparc detection
Description
Test time in seconds. The test time is the time the testing voltage is applied to the unit under test. The times for powering on and off and the ramp times are not part of the test time.
Testing voltage in Volt. This voltage is applied to the unit under test for the test time.
Minimum test current. This current must be flowing through the unit under test during the test time. If the current fallse below this limit the test is evaluated as not ok.
Maximum test current. The current must not exceed this limit during the test time. If the current exceeds this limit the test will be evaluated as not ok.
You can select how the evaluation is done. Selecting
Test
Time
the test ends after the test time. Selecting
Start-
Button
the evaluation ends with pressing the start button again.
Discharge voltage is the voltage which must be fallen short of after the test before the test step ends.
This parameter will only be visible when the
ATS400
is supporting this function.
You can select if spark detection is disabled resp. how sensitive it is. Spark detection evaluates the break down of the measured voltage regarding to size and gradient.
Selecting
Off
spark detection is disabled. Selecting
Coarse
a large spark will be detected, selecting
Normal
the sensitivity is medium and selecting
Fine
small sparks will be detected.
Additional informations about the behaviour of the high voltage test, the error messages and the evaluation you will find in the
.
User Manual ATS400 Version 3.14.41 - 1 106
Test plan editing
3.3.5
Insulation test
The insulation test will be configured using the following dialog.
Parameter t
U
R min
Result
Description
Test time in seconds. The test time is the time the testing voltage is applied to the unit under test. The times for powering on and off and the ramp times are not part of the test time.
Testing voltage in Volt. This voltage is applied to the unit under test for the test time.
Minimung allowed resistance for the evaluation.
You can select how the evaluation is done. Selecting
Test
Time
the test ends after the test time. Selecting
Start-
Button
the evaluation ends with pressing the start button again.
User Manual ATS400 Version 3.14.41 - 1 107
Test plan editing
3.3.6
Function test
The function test will be configured using the following dialog.
f t
Parameter
U
I min
I max
Description
Test voltage in Volt. This voltage is applied to the unit under test. This parameter will be ignored if the source is external.
Frequency of the test voltage. This parameter will be ignored if the source is a direct current source or external.
Test time in seconds. The test time is the time the evaluation is done against the limits. This time starts after the conditions for evaluation start is meet. This parameter will be ignored when
Button Pass/Fail
is selected.
Minimum current. Is the current below this limit the test is evaluated as failed. This parameter will be shown when
Current
is selected as measuring channel. This parameter will be ignored when
Button Pass/Fail
is selected.
Maximum current. Is the current above this limit the test is
User Manual ATS400 Version 3.14.41 - 1 108
Test plan editing
Parameter
U min
U max
Result
Graphic
Source
Voltage
Start
Description
evaluated as failed. This parameter will be shown when
Current
is selected as measuring channel. This parameter will be ignored when
Button Pass/Fail
is selected.
Minimum voltage. Is the voltage below this limit the test is evaluated as failed. This parameter will be shown when
Current
is not selected as measuring channel. This parameter will be ignored when
Button Pass/Fail
is selected.
Maximum voltage. Is the voltage above this limit the test is evaluated as failed. This parameter will be shown when
Current
is not selected as measuring channel. This parameter will be ignored when
Button Pass/Fail
is selected.
Here are two entries possible. In the the upper drop down box the method can been choosen. You can select between
Measuring canal
und
Button Pass/Fail
. In the lower drop down box the channel for evaluation is selected when
Measuring canal
is selected. Is
Button Pass/Fail selected
as method no evaluation is done and the parameters
I min
,
I max
,
U min
,
U max
and the paremeters for
Start
will be ignored.
You can select if a graphic will be diplayed and if it will be stored. Selecting
None
no graphic will be displayed and stored. Selecting
Show only
the graphic will only be displayed.
Selecting Show and Save
the graphic will be shown and saved.
Source for suppling the unit under test. The possible sources are dependent from your device. Is an external source selected you can configure if the source is a direct current source with the checkbox
Source is DC
.
Drop down box how the supplyment of the unit under test is to handle. Selecting
Turn off after test
the voltage will be turn off when test has finished. Selecting
Leave on after test
the voltage will remain on when the test has finished. Selecting
Turn off
dosn't do a test. Only the voltage will be turned off. Selecting
Turn off if test N.I.O.
the voltage will be turned off when the test is evaluated as failed. Selecting
Turn on
dosn't do a test. Only the voltage will be turned on.
Setting when the evaluation against the limits will start.
This parameter and the dependent parameters will be ignored when
Result
ist set to
Button Pass/Fail
. With the setting
After Delay
the evaluation begins after the time in
Delay
has passed. With the seting
> min
the evaluation begins when the measurement is above the limit in
I min
rsp.
U min
. With the setting
Delay and > min
the
User Manual ATS400 Version 3.14.41 - 1 109
Test plan editing
Parameter Description
time in
Delay
must have passed and the measurement is above the limit in
I min
rsp.
U min
. With the setting
Gradient
the gradinet of the measurements must have fallen below the value in
Gradient
. With the setting
< max
the evaluation begins when the mesurement has fallen below the limit in
I max
rsp.
U max
. With the setting
Delay und < max
the time in
Delay
must ahve passed and the measurement is fallen below the limit in
I max
rsp.
U max
. With the setting
> min
,
Gradient
and
< max
the evaluation must start before expiring the time in
Timeout
.
Otherwise the test is evaluated as failed.
3.3.7
Leakage current test
The leakage current test will be configured using the following dialog.
These parameters are relevant for checking.
Parameter
Delay
Description
This parameter is not used.
User Manual ATS400 Version 3.14.41 - 1 110
Test plan editing
Parameter
t
I max
I min
Result
Description
Time used for checking against the limits. If you are using a polarity with automatic change the time is valid for each polarity.
Maximum allow leakage current.
Minimum leakage current which must be reached.
Type of the channel. There are the following selesctions:
I AC rms
: Effective value of the AC-fraction
I DC
: DC-fraction of the leakage current
I min
: Lowest value of the current leakage current
I max
: Highest value of the current leakage current
I rms
: Effective value of the DC- and AC-fraction
These parameters are relevant for suppling the unit under test.
Parameter
U f triple phase sisngle phase
Source
Voltage
Description
Voltage the device under test will be supplied.
Frequency of the supply voltage for the device under test.
The unit under test is supplyed with triple phase. This radio button is active only on a test rig configured for such units under test.
Teh unit under test is supplyed with a single phase.
There are several sources available. The sources are explained in detail in chapter
Source for the supply of the device under test.
Mains voltage
: The supply is taken from the mains voltage of the ATS400.
AC 0..270V
: The supply is taken from the power converter of the ATS400.
External
: The supply is taken from an external source.
Defines how after a test the supply for the device under test is handeled.
Turn off after Test
: After the test the supply will be turned off.
This setting is fixed and cannot be changed.
These parameters are relevant for the test setup.
Parameter
Testing Modul
Description
There are several testing moduls available. the testing modules are explained in detail in chapter
.
: Touch current weighted for reaction
: Touch current weighted for to let loose
User Manual ATS400 Version 3.14.41 - 1 111
Test plan editing
Parameter
Testing method
Polarity
Description
Selects which testing method will be used.
Protective conducter current
: The current in the protective conducter will be meassured. This method is named earth leakage current in EN 60601-1:2013-12.
Touch current
: The current over the housing will be measured. For this measurement the PE-probe must be used. This method is named contact current in EN 60601-
1:2013-12.
Determines the connection of the unit unde rtest and the test setup. The contacting depends form the testing method. The contacting for the protective conducter current are explained in chapter
Polarity for protective conducter , for the touch current in chapter
In some selections the word „Auto“ is used. With this setting the change of the polarity is done automatically within one test step.
Using testing method
Protective conductor current
following connections are available:
n/S1
Closed
p/S5
Normal/Switched n/S1
Closed
p/S5
Normal n/S1
Closed
p/S5
Switched n/S1
Open p/S5
Normal/Switched
User Manual ATS400 Version 3.14.41 - 1 112
Test plan editing
Parameter Description
n/S1
Open p/S5
Normal
n/S1
Open n/S1
Closed
p/S5
Switched
Using testing method
touch current
following connections are available:
p/S5
Normal/Switched e/S7
Closed n/S1
Closed
p/S5
Normal e/S7
Closed e/S7
Closed n/S1
Closed
p/S5
Switched n/S1
Open p/S5
Normal/Switched
n/S1
Open p/S5
Normal e/S7
Closed e/S7
Closed
User Manual ATS400 Version 3.14.41 - 1 113
Test plan editing
Parameter Description
n/S1
Open p/S5
Switched
n/S1
Closed
p/S5
Normal/Switched n/S1
Closed p/S5
Normal
n/S1
Closed p/S5
Switched e/S7
Closed e/S7
Open e/S7
Open e/S7
Open
User Manual ATS400 Version 3.14.41 - 1 114
Test plan editing
3.3.7.1 Testing modules
IEC60990 Pic 3
Measuring circuit for unweighted touch current (corresponds EN61010-1 Pic A.3)
This measuring model emulates the impedance of the human body. This allows sto measure the current flowing through a human body touching the unit under test in a similar way.
IEC60990 Pic 4
Measuring circuit for touch current weighted for reaction (corresponds EN61010 Pic
A1)
Reaction in the human body results from the current flowing within the body. The measuring circuit according to picture 4 emulates the impedance of the body and
User Manual ATS400 Version 3.14.41 - 1 115
Test plan editing
weight the reaction depended from the current causing an unwanted reaction.
IEC60990 Pic 5
Measuring circuit for touch current weighted for let loose
The inability to let loose the unit under test results from a current flow within the human body (e.g. through muscles). the influence of the frequency for let losse is different from the influence for reaction. this is significant for frequencies above 1 kHz.
IEC 60601 Basic
Measuring circuit
This measuring circuit corresponds to the requirement of DIN EN 60601-1:2013-12 chapter 8.7.3 part e.
User Manual ATS400 Version 3.14.41 - 1 116
Test plan editing
IEC 60601 Pic 12
Measuring circuit with weighting
This measuring circuit corresponds to the requirement of DIN EN 60601-1:2013-12 chapter 8.7.3 part a - d.
3.3.7.2 Supply options
Mains voltage
The unit under test is supplied from the mains voltage of the ATS400.
There is no isolation from the mains voltage.
User Manual ATS400 Version 3.14.41 - 1 117
Test plan editing
AC 0..270V
The unit under test is supplied by the power converter in the ATS400.
The isolation is within the ATS400.
Extern
The unit under test is supplied over an external input.
An insulation can be done by an external transfomer.
User Manual ATS400 Version 3.14.41 - 1 118
Test plan editing
3.3.7.3 Polarity for protective conducter
The following polarities are available with the measuring method
protective conducter current
.
L1->PE
resp. 1. phase
Auto
L2->PE
resp. 2. phase
Auto
User Manual ATS400 Version 3.14.41 - 1 119
Test plan editing
L1->PE with SFC
resp. 1. phase
Auto with SFC
L2->PE with SFC
reap. 2. phase
Auto with SFC
User Manual ATS400 Version 3.14.41 - 1 120
Test plan editing
3.3.7.4 Polarity for touch current
The following polarities are available with the measuring method
touch current
.
L1->PE
resp. 1. phase
Auto
L2->PE
resp. 2. phase
Auto
User Manual ATS400 Version 3.14.41 - 1 121
Test plan editing
L1->PE with Auto
resp. 1. phase
Auto with Auto
L2->PE with Auto
resp. 2. phase
Auto with Auto
User Manual ATS400 Version 3.14.41 - 1 122
Test plan editing
SFC PE Open
resp. 1. phase
SFC PE Open Auto
SFC PE Open reverse
resp. 2. Phase
SFC PE Open Auto
User Manual ATS400 Version 3.14.41 - 1 123
Test plan editing
3.3.8
Batch
The batch data will be configured using the following dialog.
With the test step
Batch
you can enter data for a charge.
The entered data will be stored in the result file and report file and can be printed locally. This test type can be configured individually. In the top most entry field a preset user can be entered or by activating the checkbox
from Username
the currently logged in user will be used. Also the entry field
Test equipment
can be preset or the name of the worksation can be used. In the both middle fields a type and ordern number can be preset. To generate a sequential serial number you can preset the first serial number. The serial number can be automatical increased on passed and/or failed tests. In this case the serial numer must not contain any alphabetic characters. The start conditions can be set as usual.
Using the additional checkboxes the fields can provided with
. This allows the input to be checked for plausibility.
User Manual ATS400 Version 3.14.41 - 1 124
Test plan editing
3.3.9
Data input
The data input will be configured using the following dialog.
You can configure up to 5 fields to enter any data. Is the corresponding checkbox
Pattern
active the preset will be used as a
Pattern . This allows the input to be
checked for plausibility.
User Manual ATS400 Version 3.14.41 - 1 125
Test plan editing
3.3.10 Resistance
The resistance test will be configured using the following dialog.
Depending on the configuration and firmware of the
ATS 400
not all parameters will be displayed.
Parameter t
R min
R max
R offset
Timeout
Measuring range
Description
Test time, the evaluation will be done when it is elapsed.
Lower limit for the evaluation.
Upper limit for the evaluation.
Offset to compensate the resistance of the measurement cables. This value will be subtracted from the measurement value before evaluation.
Time within that valid measurements must be present.
Selection for the measurement range.
0: Automatic
User Manual ATS400 Version 3.14.41 - 1 126
Test plan editing
Parameter Description
Other values depends from the configuration of the
ATS 400
.
3.3.11 Matrix
The matrix test step will be configured using the following dialog.
This step can only be chossen in the case a
configuration file for a matrix is present.
Parameter
Off
Description
Both outputs of the ETL-Interface are off and all relais of a matrix are in default position.
This checkbox is always disabled.
Matrix ETL-
Interface
ETL-IO: Out 7
(Pin9)
ETL-IO: Out 8
(Pin10)
This checkbox is always disabled.
This checkbox is always disabled.
User Manual ATS400 Version 3.14.41 - 1 127
Test plan editing
Parameter
Matrix CAN t
Description
This checkbox can be selected in the case a cofiguration file for a matrix is existent. If the checkbox is active the matrix can be configured.
This time determines how long the step will be executed.
This can be used to make external measurements.
On the sub property page
Relaismatrix
are controls to configure the matrix.
Parameter
Bank
Reset
HV1
HV2
Description
With the buttons it can be switched between the banks of the different outputs. If there is a non default setting in a bank a yellow field will be displayed near the button.
Sets als outputs to the default setting.
If a button in this line is set the wire HV1 is switched to the coresponding output.
In this line the number of the outputs of the active bank are displayed.
If a button in this line is set the wire HV2 is switched to the coresponding output.
In the example above the output 1 is connected to wire HV1 and output 2 is connected to wire HV2.
User Manual ATS400 Version 3.14.41 - 1 128
Test plan editing
3.3.12 Continuity test
The continuity test will be configured using the following dialog.
Parameter
Interpretation
Limit
Test time
Test voltage
Max. test current
Description
Closed
: The test will be evaluated as passed if a resistance lower than
Limit
will be measured.
Open
: The test will be evaluated as passed if a resistance higher than
Limit
will be measured.
Limit for the evaluation.
Time after that the measurement will be evaluated.
Maximum test voltage used for the measurement.
Maximum current during the test.
User Manual ATS400 Version 3.14.41 - 1 129
Test plan editing
3.4
Test plan settings
This section discusses the settings that are valid for the entire test plan.
The associated window can be opened using the
Plan Options
button in the
Create / Edit
window.
The window with the
Planoptions
opens.
User Manual ATS400 Version 3.14.41 - 1 130
Test plan editing
3.4.1
Text
You can enter a free text here.
User Manual ATS400 Version 3.14.41 - 1 131
Test plan editing
3.4.2
Identification
Here you can configure identifications which are used for automatic plan selection.
With the button
New
you can enter an new idetification.
With the button
Delete
the selected identification will be deleted.
The identifications will be used for automatic plan selection.
User Manual ATS400 Version 3.14.41 - 1 132
Test plan editing
3.4.3
Report options
The report options provide the possibility to convert the results data into another format. For part of the options,
When calling up for the first time, no report options are yet active.
User Manual ATS400 Version 3.14.41 - 1 133
Test plan editing
Click on the
Change
button. The dialogue changes, which means that the report selected can be edited.
Activate one or more of the
IO
,
NIO
or
Error
checkboxes so that the report is created for the corresponding overall result.
User Manual ATS400 Version 3.14.41 - 1 134
Test plan editing
Select the desired report type from the dropdown box.
For the
Printer
,
Save as HTML
and
Save as PDF
options, you need to select an
HTML template.
With the
Save as XML
option, you can select a style sheet.
With the
Save as CSV
option you need to select a CSV template.
With the
Print on Zebra Lableprinter
option, you need to select a ZPL file.
With the
Printer
and
Print on Zebra Lableprinter
options, you can additionally select a printer. If you do not select a printer, the current standard printer is used to print.
User Manual ATS400 Version 3.14.41 - 1 135
Test plan editing
When clicking on the Template or Printer fields, the corresponding standard dialogue of
Windows opens.
With the
Ok
button, you can assume the data from the report selected. With the
Cancel
button, the changes are dismissed.
With the
Save as HTML
,
Save as PDF
,
Save as XML
und
Save as CSV
options a new file is created. The place of saving and the file name are guided by the settings in
Settings
->
File storage
->
Result
.
User Manual ATS400 Version 3.14.41 - 1 136
Test plan editing
3.4.4
Info
Here it will displayed when and on which workstation and which user the test plan was created or changed. If there was no
workstation name configured rsp. the
user administration was not active the according fields are empty.
User Manual ATS400 Version 3.14.41 - 1 137
Test plan editing
3.4.5
Options
This option will not be used any more. This option has expanded and is now part of the
User Manual ATS400 Version 3.14.41 - 1 138
Inspector
4 Inspector
This part of the manual is aimed for those persons using the program for testing.
This part described the general procedures for using. Regarding to the different situations this part cannot describe the concrete situation at a test station.
4.1
Test individual
Open the dialog choosing
Test individual
.
There is a button for each test type. The buttons for the available test types on your
ATS400
are operational.
The window for each test type is the same. In the following this is described with the protective earth test as an example.
User Manual ATS400 Version 3.14.41 - 1 139
Inspector
4.1.1
Protective earth test
You will do a protective earth test in this window.
Before the first test no values will be displayed. During and after the test the values will be displayed.
A white background means that no test has been done.
A yellow background means that a test is currently executing.
A green background means that the last test was evaluated as passed.
A red background means that the last test was evaluated as failed.
Button
Menu
Edit
Back
Action
This button is operational when no test is executed.
The main menu will be displayed.
This button is operational when no test is executed.
The
configuration dialog will be displayed.
The window will be closed. During a test the button changes to
Cancel
.
User Manual ATS400 Version 3.14.41 - 1 140
Inspector
Button
Cancel
4.2
Test plan
Open the dialog choosing
Test plan
.
Action
The currently running test will be aborted.
The test will be evaluated as failed. The button changes to
Back
.
Button
Menu
Select manual
Select ID
Test batch
User Manual ATS400
Action
The main menu will be displayed.
The window for
will be opened.
The window for
automatic test plan selection will be opened. Using this
selection the test plan will be closed after the test of one unit under test.
The window for
automatic test plan selection will be opened. Using this
Version 3.14.41 - 1 141
Inspector
Button
Create / Edit
Dummytest
Main menu
Action
selection the test plan will be closed by the tester.
This button is not operational when the
ETL-
Interface
or
File Plan.ID
for automatic test plan selection.
The window for
will be opened.
This button is operational when a
dummy test plan is present. A dummy test will be
done.
The main menu will be displayed.
4.2.1
Manual test plan selection
Open the dialog choosing
Test plan
->
Select manual
.
On the left side the list of the existing test plans are displayed.
In the midth upper part the test steps in the selected test plan are displayed. Is no
User Manual ATS400 Version 3.14.41 - 1 142
Inspector
test plan selected the list is empty.
In the midth lower part the data for the test step is displayed. Is no test plan or no test step selected the list is empty.
Button
Menu
Test
Plan information
Back
Action
The main menu will be displayed.
The window
Test plan
will be opened.
The window for
opened.
In this mode you cannot do any changes.
The window will be closed.
4.2.2
Automatic test plan selection
Open the dialog choosing
Test plan
->
Select ID
or
Test plan
->
Test batch
.
The number of the displayed fields depends on how the automatic test plan selection is
configured . In this example the maximum number of fields is displayed and is
acccording to the example
Article number and serial number with additionally activated
User Manual ATS400 Version 3.14.41 - 1 143
Inspector
checkbox for the article description.
Button
Menu
Back
Action
The main menu will be displayed.
The window will be closed.
4.3
Safety cabinet
The safety cabinets are built this way that they are locked when they are not supplied by the
ATS400
. After powering on the
ATS400
they are unlocked and can be opened.
Depending how the
ATS400
is setup in the
ETL DataView 3
behaves different together with the safety cabinet.
The setting
Locked during plan
prevents an influence during executing a test plan.
The safety cabinet can be opened after the test plan has completed.
The setting
Unlock on pass
also contains a process control. In the case a test will be evaluated as failed the safety cabinet will be unlocked after a second action for unlocking. Dependend from the configuration of the saftey cabinet this can be done with the button
Cancel
and always with the button
Unlock
in
ETL DataView 3
.
User Manual ATS400 Version 3.14.41 - 1 144
Inspector
When the safety cabinet is unlocked the message
Open safety cabinet
will be displayed until the safety cabinet has been opened.
User Manual ATS400 Version 3.14.41 - 1 145
Report creation
5 Report creation
This part of the manual is aimed at the persons who create and edit the report templates.
It contains information that is necessary to create report templates that are required for the individual report options.
5.1
Creating templates
For the use of the
Printer
,
Save as HTML
and
Save as PDF
report options, you need to create an
.
When using the
Save as XML
report option, you can create a style sheet.
To use the
Save As CSV
report option, you need to create a
.
To use the
Print on Zebra Lableprinter
option, you need to create a ZPL file as a template.
All templates have in common that the data can be accessed via
5.1.1
Key words
You can access the data of the results files via key words. The key words always consist of prefix
TAG_
and the postfix
_TAG
.They are not displayed in the following tables. Upper and lower case is considered for the key words. Assume the key words in the way as they are written in the following tables.
Key words that apply for the entire test plan have the form
TAG_<key word>_TAG
.
Key words that apply for a test view have the form
TAG_<step>_<key word>_TAG
. In doing so, it is defined in
<step>
what test step is accessed. If
<step>
has the value
##
, every test step of the test plan is accessed. In this case, the key word must exist in a cell of a table. If
<step>
has the value
#n
, while
n
is a number counted from
1, precisely this step is accessed. In this case, the key word can also be used outside a table.
Key words that refer to the multiple test data of a test step have the form
TAG_<step>_Multitest_<Multitest>_<key word>_TAG
. In doing so, it is defined in
<Multitest>
what multiple test is accessed. If
<Multitest>
has the value
##
, every multiple test is accessed. In this case, the key word must exist in a cell of a table. If
<Multitest>
has the value
#n
, while
n
is a number counted from 1, precisely this multiple test is accessed.
5.1.1.1 Key words of the results data
This section describes all key words that apply for the total test plan and are addressed with the form
TAG_<key word>_TAG
.
Key words that are part of every results file:
Key word
DataView_Version
Explanation
Version of
ETL DataView 3
with which this file
User Manual ATS400 Version 3.14.41 - 1 146
Report creation
Key word
PlanName
PlanPath
PlanDescription
Explanation
was created.
Name of the test plan, is filled with the file name when being created.
Relative path to the application where the test plan was saved.
Description of the test plan. This value can be entered by the user in
Settings
->
Text
.
PlanCreatedByUser
User who created the test plan first. If user administration is not active, the field is empty.
PlanCreatedByWorkstation
Test station where the test plan was created.
The name of the test station can be stated in
Settings
->
Workstation
->
Base settings
.
PlanCreatedOnDate
PlanEditedByUser
PlanEditedByWorkstation
Date of creating the test plan. The date is in the format in accordance with the country settings valid at this moment in time.
User who modified the test plan last. If user administration is not active, the field is empty.
Test station where the test plan was modified last. The name of the test station can be stated in
Settings
->
Workstation
->
Base settings
.
PlanEditedOnDate
PlanIdentificationEnabled
The
<ResultData>\<Identification>
block exists.
PlanBatchEnabled
Date of modifying the test plan. The date is in the format in accordance with the country settings valid at this moment in time.
PlanTestSteps
Intended for future purposes.
Number of test steps in the test plan.
PlanSelectMode
PlanSelectPatternID
PlanSelectPatternTyp
PlanSelectPatternSerie
Selection method for plan selection via identification
Template to identify the PlanID
Template to identify the type if it is entered with the ID.
Template to identify the serial number if it is entered with the ID.
PlanSelectPatternMask
DATE
Bit template:
1: Combined field (2+4)
2: Entry type
4: Entry series
8: Entry articelnumber
Date of the test in the local date format.
User Manual ATS400 Version 3.14.41 - 1 147
Report creation
Key word
TIME
TESTER
PLAN_NAME
WORKSTATION
USEDID
RESULT
FileSavedByUser
FileSavedByWorkstation
FileSavedOnDate
Count_Tests
Count_IO
Count_NIO
Count_ERROR
PlanCycleTime
PlanStandbyTime
IDs
ID_n
Explanation
Time of the test in the local time format.
User logged in.
Name of the test plan used.
Name of the test station.
ID used for the automatic test plan selection.
Total result of the plan.
Passed
-> The test item has passed the test.
Failed
-> the test item has not passed the test or the test was cancelled.
User who saved the test plan or the result file.
Test station where the test plan or the result file was saved. The name of the test station can be stated in
Settings
->
Workstation
->
Base settings
.
Date of saving the test plan or the result file.
The date is in the format in accordance with the country settings valid at this moment in time.
Number of tests that were carried out since starting the test plan.
Number of IO results of the test since starting the test plan.
Number of NIO results of the test since starting the test plan.
Number of errors of the test since starting the test plan.
Duration for carrying out the test. The value is always 0.
Duration between the end of the prior test and the start of the current test.
Number of IDs.
Identification for the test plan. The tags are numbered from 0 to the number of IDs - 1, i.e.
have the values ID_0, ID_1, etc.
Key words that are part of the
Batch run
test step:
Key word
Benutzer
Pruefplatz
Explanation
User field, can be adopted from the login.
Test station field, can be adopted from
User Manual ATS400 Version 3.14.41 - 1 148
Report creation
Key word
Typ
Auftragsnummer
Seriennummer
Explanation
the workstation settings.
Type, can already be entered during the automatic test plan selection.
Order number
Serial number, can already be entered during the automatic test plan selection. If this value is numerical, it can be automatically increased for IO or
NIO.
Key words that are entered via the automatic test plan selection:
Key word
TYPE
USEDID
SERIALNUMBER
ARTICLE
Explanation
Type of the test item, is only filled in if the combibox is active.
ID used to select the test plan, is only filled in when the
ID-Pattern
field is active.
Serial number of the test item, is only filled in if the
Serial-Pattern
field is active.
Article name, is only filled in if the
Article-Pattern
field is active.
5.1.1.2 Key words of the test step parameters
The following key words are common for all test steps. These key words are addressed with the form
TAG_<step>_<key word>_TAG
.
Key words for the parameters:
Key word
UNIT
UNIT2
MIN
MAX
StartCondition
Explanation
Unit of the measurement value
Unit of the test size
Minimum value of the measurement value.
Maximum value of the measurement value.
Start conditions of the test step. The start conditions are saved in a bitcoded manner and can only be analysed together with the
StartConditionMask
field.
User Manual ATS400 Version 3.14.41 - 1 149
Report creation
Key word
StartConditionMask t_delay
StateChangeBits
StartStateChange
StartStateJump
Explanation
Start conditions of the test step. The start conditions are saved in a bitcoded manner and can only be analysed together with the
StartCondition
field.
Start delay between fulfilling the start condition and the start of the test.
Always 0, never used.
Indicates whether the switching condition needs to be maintained when testing the start conditions.
0 = no waiting for switch condition
1 = Wait for switching condition
Indicates whether the
Jump
button is displayed.
Repeating
StartButton
PassButton
StartandJump
Indicates how often the test step is carried out.
Indicates whether the
Start
button is displayed.
Indicates whether the
Pass
button is displayed.
Indicates whether the
Start
and
Jump
buttons are displayed.
The
,
,
,
Matrix
,
nd
test types use the following parameters in addition:
Key word
Polung
PolungCAN_00
bis
Multitest_Enable
PolungCAN_15
Explanation
Contacting setting of an external relay matrix.
Setting of the relay matrix in accordance with the choice in the program. The display is bit coded.
Multitest is active, if the value does not equal 0.
Multitest_Auswertung
Multitest_Endekriterium
Method of analysing the multitest.
0 = worst measurement value.
Method of ending the multitest.
0 = number of measurements
User Manual ATS400 Version 3.14.41 - 1 150
Report creation
Key word
Multitest_Endekriterium_Anzahl
Explanation
1 = pass key
Number of multitest inspections.
The
,
,
Matrix
,
nd
test types use the following parameters in addition:
Key word
ErrorStartCondition
ErrorStartConditionMask
ErrorStateChangeBits
ErrorWSBDelay
ErrorWSBTimeValid
Explanation
Condition for switching forward in the event of an error.
Mask for the condition for switching further in the event of an error.
Always 0, never used.
Delay of switching further in the event of an error.
Delay time active.
5.1.1.2.1 Key words of the Protective earth test type
The
Protective earth
test type additionally uses the following key words:
Key word
U
I
R_max t f
EN60204
DC_Enable
Explanation
Idle voltage
Test current
Upper threshold value of the resistance.
Test time
Frequency of the voltage
Indication whether the test is performed in accordance with EN 60204.
Always 0.
Indicates whether the test is carried out with direct current voltage.
0: Alternating current
1: Direct current
User Manual ATS400 Version 3.14.41 - 1 151
Report creation
5.1.1.2.2 Key words of the High Voltage AC test type
The
High voltage AC
test type additionally uses the following key words:
Key word
U
I_min
I_max t
Ramp
U_start t_up t_down f
Quelle f_Source
U_Source
Management
Auswertung
CreateLog
Timeinterval
Explanation
Test voltage
Lower threshold
Upper threshold
Test duration
Indicates whether the ramp is active.
Start voltage
Increase time of the ramp. This parameter is only valid if the ramp is active.
Drop time of the ramp. This parameter is only valid if the ramp is active.
Frequency of the voltage
Selected current source.
This parameter is only used in the event of a hot high voltage.
Frequency of the source.
This parameter is only used in the event of a hot high voltage.
Voltage of the source.
This parameter is only used in the event of a hot high voltage.
Indicates how the supply of the test item is to be carried out.
0: Power off after test
1: Keep power on after test
2: Only power off
3: Power off only on error
4: Only power on
Type of the analysis of the test.
0 = end the test time
1 = end with start signal
Indicates whether a log file will be created.
0 = No log file will be created
1 = A log file be created
Time interval between two samples which will be written to the log file. The value is in seconds.
This value will only be used in case the value in
CreateLog
is 1.
User Manual ATS400 Version 3.14.41 - 1 152
Report creation
5.1.1.2.3 Key words of the High voltage DC test type
The
High voltage DC
test type additionally uses the following key words:
Key word
U
I_min
I_max t
Ramp
U_start t_up t_down
U_discharge
Quelle f_Source
U_Source
Management
Auswertung
CreateLog
Timeinterval
Explanation
Test voltage
Lower threshold
Upper threshold
Test duration
Indicates whether the ramp is active.
Start voltage
Increase time of the ramp. This parameter is only valid if the ramp is active.
Drop time of the ramp. This parameter is only valid if the ramp is active.
Discharge voltage
Selected current source.
This parameter is only used in the event of a hot high voltage.
Frequency of the source.
This parameter is only used in the event of a hot high voltage.
Voltage of the source.
This parameter is only used in the event of a hot high voltage.
Indicates how the supply of the test item is to be carried out.
0: Power off after test
1: Keep power on after test
2: Only power off
3: Power off only on error
4: Only power on
Type of the analysis of the test.
0 = end the test time
1 = end with start signal
Indicates whether a log file will be created.
0 = No log file will be created
1 = A log file be created
Time interval between two samples which will be written to the log file. The
User Manual ATS400 Version 3.14.41 - 1 153
Report creation
Key word
CheckCurrentInRamp
Explanation
value is in seconds.
This value will only be used in case the value in
CreateLog
is 1.
During a HVDC7 test the current will be checked against the limit Imax also during executing a ramp.
5.1.1.2.4 Key words of the Insulation test type
The
Insulation
test type additionally uses the following key words:
Key word
U
R_min t
Ramp
U_start t_up t_down
U_discharge
Quelle f_Source
U_Source
Management
Auswertung
Explanation
Test voltage
Lower threshold of the insulation resistance.
Test duration
Indicates whether the ramp is active.
Start voltage
Increase time of the ramp. This parameter is only valid if the ramp is active.
Drop time of the ramp. This parameter is only valid if the ramp is active.
Discharge voltage
Selected current source.
This parameter is only used in the event of a hot high voltage.
Frequency of the source.
This parameter is only used in the event of a hot high voltage.
Voltage of the source.
This parameter is only used in the event of a hot high voltage.
Indicates how the supply of the test item is to be carried out.
0: Power off after test
1: Keep power on after test
2: Only power off
3: Power off only on error
4: Only power on
Type of the analysis of the test.
0 = end the test time
1 = end with start signal
User Manual ATS400 Version 3.14.41 - 1 154
Report creation
Key word
CreateLog
Timeinterval
Explanation
Indicates whether a log file will be created.
0 = No log file will be created
1 = A log file be created
Time interval between two samples which will be written to the log file. The value is in seconds.
This value will only be used in case the value in
CreateLog
is 1.
5.1.1.2.5 Key words of the FCT-Current test type
The
FCT-Current
test type additionally uses the following key words:
Key word
U_Source
U
I_min
I_max t f t_start t_timeout
Gradient
Management
Explanation
Source of the test supply.
Voltage of the test item supply
Lower threshold value during the analysis. Not valid if the analysis is set to
Pass/Fail
. The unit and thresholds depend on the channel.
Upper threshold value during the analysis. Not valid if the analysis is set to
Pass/Fail
. The unit and thresholds depend on the channel.
Test time
Frequency of the voltage
Delay time for the start scenario when starting the test until starting the analysis. This value is not valid for all start scenarios.
Timeout for the start of the analysis.
The value is not used for all start scenarios.
Gradient for the start of the analysis.
This value is not used for all start scenarios.
Indicates how the supply of the test item is to be carried out.
0: Power off after test
1: Keep power on after test
2: Only power off
3: Power off only on error
4: Only power on
User Manual ATS400 Version 3.14.41 - 1 155
Report creation
Key word
Scenario
Auswertung
Kanal
SourceIsDC
Graphic
CreateLog
Timeinterval
UseAnalogConversion
ConversionOffset
ConversionGradient
PhysicalUnit
Explanation
Type of the start of the analysis
Type of the analysis
0 = measurement
1 =
Pass/Fail
button
Measurement channel
0 = current
1 = analogue channel1
2 = analogue channel2
3 = analogue channel3
4 = analogue channel4
5 = voltage measurement
External source provides direct current voltage
Type of the graphics settings
0 = no graphics
1 = only display graphic
2 = display and save graphic
Indicates whether a log file will be created.
0 = No log file will be created
1 = A log file be created
Time interval between two samples which will be written to the log file. The value is in seconds.
This value will only be used in case the value in
CreateLog
is 1.
This check box inidcates whether the analog input will be converted to customer specific units.
0 = No conversion
1 = Do conversion
Value of the physical value when the voltage has valaue 0.
This field is only valid when
UseAnalogConversion
has the value 1.
Slope for the conversion of the voltage into the physical value.
This field is only valid when
UseAnalogConversion
has the value 1.
Physical unit of the customer specific conversion.
This field is only valid when
UseAnalogConversion
has the value 1.
User Manual ATS400 Version 3.14.41 - 1 156
Report creation
5.1.1.2.6 Key words of the Leakage current test type
The
Leakage current
test type additionally uses the following key words:
Key word
Messmodell
Messmethode
Management
U_Source
U
I_max t f t_start
Auswertung
Polaritaet
SelftestMode
I_min
Explanation
Measurement model used.
Measurement method used.
0: Protective conductor current
1: Housing discharge current
Indicates how the supply of the test item is to be carried out.
0: Power off after test
1: Keep power on after test
2: Only power off
3: Power off only on error
4: Only power on
Source of the test supply.
Voltage of the test item supply
Upper threshold for the discharge current.
Test time
Frequency of the voltage
Will not be used.
Measurement channel used for the test:
0: I AC rms
1: I DC
2: I min
3: I max
4: I rms
Polarity used of the supply of the test item.
For single-phase test item:
0: Automotive
1: L1-> PE
2: L2-> PE
3: Mode B
4: Automatic with first error
5: L1 -> PE with first error
6: L2 -> PE with first error
With three-phase test item:
0: Clockwise rotation
1: Counterclockwise rotation
Always 0
Lower threshold for the discharge
User Manual ATS400 Version 3.14.41 - 1 157
Report creation
Key word
Phase
CreateLog
Timeinterval
Explanation
current.
Number of phases of the test item.
Indicates whether a log file will be created.
0 = No log file will be created
1 = A log file be created
Time interval between two samples which will be written to the log file. The value is in seconds.
This value will only be used in case the value in
CreateLog
is 1.
5.1.1.2.7 Key words of the Sight check test type
The
Sight check
test type additionally uses the following key words:
Key word
Abfrage
Explanation
Mode for termination.
5.1.1.2.8 Key words of the Data input test type
The
Data input
test type additionally uses the following key words:
Key word
EingabeMasken
Explanation
Bit samples containing screen fields instead of requirements.
5.1.1.2.9 Key words of the Batch run test type
The
Batch run
test type additionally uses the following key words:
Key word
SettingFlags
EingabeMasken
Explanation
Settings that indicate that certain fields are configured at other locations. This field is bit coded.
Bit samples containing screen fields instead of requirements.
5.1.1.2.10 Key words of the User-Interface test type
The
User-Interface
test type additionally uses the following key words:
Key word
In
Explanation
Entry bits
User Manual ATS400 Version 3.14.41 - 1 158
Report creation
Key word
InMask
Out
OutMask
Duration
Timeout
TimeoutEnable
NumInterface
Explanation
Mask for entry bits.
Output bits
Mask for output bits.
Duration of the output pulse.
Timeout when waiting for the status of the entry bits.
This parameter is only valid if the
TimeoutEnable
parameter is set.
States whether timeout is used.
0: Timeout is not used
1: Timeout is used
Number of the user IO interface used.
0: User-IO Interface of the internal IO-
CPU
1: User-IO Interface of the external IO-
CPU
5.1.1.2.11 Key words of the Resistance test type
The
Resistance
test type additionally uses the following key words:
Key word t
R_min
R_max
R_offset t_timeout
Explanation
Test time
Lower threshold value of the resistance.
Upper threshold value of the resistance.
Resistance of the measurement structure.
Maximum time after starting until the first measurement value is recorded.
5.1.1.2.12 Key words of the Continuity test type
The
Continuity
test type additionally uses the following key words:
Key word
TestVoltage
TestTime
MaxTestCurrent
Limit
Explanation
Maximum test voltage used for the measurement.
Time after that the measurement will be evaluated.
Maximum current during the test.
Limit for the evaluation.
User Manual ATS400 Version 3.14.41 - 1 159
Report creation
Interpretation
TypeOfSource
Evaluation of the measurement:
1: Pass on continuity
2: Pass on discontinuity
Type of the used source:
0: Alternating current
1: direct current
5.1.1.2.13 Key words of the PT100 test type
The
PT100
test type additionally uses the following key words:
Key word
T_min
T_max
R_offset
R0
Explanation
Lower threshold for the temperature.
Upper threshold for the temperature.
Resistance of the measurement structure.
Basic resistance of the measurement sensor.
5.1.1.2.14 Key words of the Lightcontrol test type
The
Lightcontrol
test type additionally uses the following key words:
Key word
Leuchte_ART
Leuchte_BEFEHL
Leuchte_DIM
Leuchte_DALIC
Leuchte_DALIV
Leuchte_DIMT
Explanation
Type of the light
Command to the light
Dim value
DALIC
DALIV
DIMT
5.1.1.2.15 Key words of the Dummy load test type
The
Dummy load
test type additionally uses the following key words:
Key word
Management
U_Source
Explanation
Indicates how the supply of the test item is to be carried out.
0: Power off after test
1: Keep power on after test
2: Only power off
3: Power off only on error
4: Only power on
Source of the test supply.
User Manual ATS400 Version 3.14.41 - 1 160
Report creation
Key word
U f
Channels
RGas
RCoil
Filament_enable
Filament_t
Filament_delay
Filament_I
Ignition_enable
Ignition_t
Ignition_delay
Ignition_U
Fct_enable
Fct_t
Fct_delay
Fct_Imin
Fct_Imax t_timeout
Filament_Imax
Explanation
Voltage of the test item supply
Frequency of the voltage
Number of channels
Gas resistance
Coil resistance
Active flame
Active flame
Flame delay
Current of the flame
Ignition available
Ignition time
Ignition delay
Ignition voltage
Function available
Duration of the function
Delay of the analysis
Lower threshold value of the current
Upper threshold value of the current
Always 0
Max. current of the flame
5.1.1.2.16 Key words of the Light Filament current test type
The
Light Filament current
test type additionally uses the following key words:
Key word
Management
Filament_enable
Filament_t
Filament_delay
Filament_I
Filament_Imax
Explanation
Indicates how to proceed after the test with supplying the test item.
0: Deactivate
1: Activate
Active flame
Active flame
Flame delay
Current of the flame
Max. current of the flame
User Manual ATS400 Version 3.14.41 - 1 161
Report creation
5.1.1.2.17 Key words of the External programm test type
The
External program
test type additionally uses the following key words:
Key word
SettingFlags
Explanation
Settings
5.1.1.3 Key words of the test step measurement values
Every test step has the following fields:
Key word
COUNTIO
COUNTNIO
COUNTERR
CountTests
StepCycleTime
Result dblResultValue1 dblResultValue2 strResultValue1 strResultValue2 strResultTestTime
ERROR
Explanation
Number of times this step was successfully carried out.
Number of times not carried out successfully.
Number of cancelled tests.
Total number of tests carried out.
Duration of the test.
Result of the test step:
UnTested
-> This test step was not carried out during this test.
Active
-> Test step is active, cannot occur in the file.
IO
-> This test step was rated as IO.
NIO
-> This test step was rated as NIO.
ERROR
-> This test step was cancelled with an error.
Jumped
-> This test step was skipped.
Numeric measurement value in SI unit.
Numeric value of the test size in SI units.
Formatted measurement value with a unit.
Formatted test value with a unit.
Formatted duration of the test in seconds.
Indication of the error when cancelling the measurement.
None
-> No error
Timeout_StartMeasurement
-> Time error when starting the measurement
Timeout_SetPassFail
-> not used
Timeout_MeasureTimeOvershoot
-> measurement time exceeded
User Manual ATS400 Version 3.14.41 - 1 162
Report creation
Key word
ERRORinfo
TestingUser
SightCheckInputText
Explanation
Invalid_TestState
-> invalid test status
Invalid_TestResult
-> invalid test result
Invalid_PVSteuerLT
-> invalid control word
Invalid_PVStatusPruefung
-> invalid status of the test
Invalid_TestParameter
-> invalid test parameter
Cancel
-> cancelled
Expanded error number.
User loged in during the test step.
User entry during the visual inspection.
5.1.1.4 Key words of the multiple test values test step
Every multiple test has the following fields:
Key word dblTestResult strTestResult
TestPoint
MultitestUser
Explanation
Result value of the multiple test in the
SI unit. This field contains only a figure value.
Result value as text.
User input for the multitest.
User loged in during the multitest.
5.1.1.5 Key words of the test step advices
Every test step has the following fields:
Key word
TextCount
Text_0
TextEnable_0
TextSize_0
Picture_0
Explanation
Always 3
Text to be output with indication beforehand.
Activation of the output with indication beforehand.
Font size with indication beforehand.
File name of the image with indication beforehand.
If the file can be reached via a relative path from the folder of the plan files,
User Manual ATS400 Version 3.14.41 - 1 163
Report creation
Key word
Outputtype_0
OutputSize_0
Text_1
TextEnable_1
TextSize_1
Picture_1
Outputtype_1
User Manual ATS400
Explanation
the relative path is entered, otherwise the absolute path is entered.
Image or text display with indication beforehand.
Values used:
Text
displays the text only.
Bild
displays the image only.
TextBild
displays the text and the image.
TextWithInputField
displays the text and an input field.
Small or large display with indication beforehand
Values used:
TextKlein
displays the small window for the text.
TextGroß
displays the large window for the text.
BildKlein
displays the small window with the image.
BildGroß
displays the large window with the image.
TextMitEingabeFeldKlein
displays the small window for the text and the input field.
TextMitEingabeFeldGroß
displays the large window for the text and the input field.
Nichts
displays no field.
Text to be output with indication during.
Activation of the output with indication during.
Font size with indication during.
File name of the image with indication during.
If the file can be reached via a relative path from the folder of the plan files, the relative path is entered, otherwise the absolute path is entered.
Image or text display with indication during
Values used:
Text
displays the text only.
Bild
displays the image only.
TextBild
displays the text and the image.
Version 3.14.41 - 1 164
Report creation
Key word
OutputSize_1
Text_2
TextEnable_2
TextSize_2
Picture_2
Outputtype_2
OutputSize_2
User Manual ATS400
Explanation
TextWithInputField
displays the text and an input field.
Small or large display with indication during.
Values used:
TextKlein
displays the small window for the text.
TextGroß
displays the large window for the text.
BildKlein
displays the small window with the image.
BildGroß
displays the large window with the image.
TextMitEingabeFeldKlein
displays the small window for the text and the input field.
TextMitEingabeFeldGroß
displays the large window for the text and the input field.
Nichts
displays no field.
Text to be issued in the event of error.
Activation of the output in the event of an error.
Font size in the event of an error.
File name of the image in the event of an error.
If the file can be reached via a relative path from the folder of the plan files, the relative path is entered, otherwise the absolute path is entered.
Image or text display in the event of an error.
Values used:
Text
displays the text only.
Bild
displays the image only.
TextBild
displays the text and the image.
TextWithInputField
displays the text and an input field.
Small or large display in the event of an error.
Values used:
TextKlein
displays the small window for the text.
TextGroß
displays the large window for the text.
Version 3.14.41 - 1 165
Report creation
Key word Explanation
BildKlein
displays the small window with the image.
BildGroß
displays the large window with the image.
TextMitEingabeFeldKlein
displays the small window for the text and the input field.
TextMitEingabeFeldGroß
displays the large window for the text and the input field.
Nichts
displays no field.
5.1.1.6 Key words of the test step process control
Every test step has the following fields:
Key word
Test
TestName
TestNameAbbr
Execute
InvertResult
View
Jump_IO_Mode
Jump_IO_Jump
Jump_IO_Repeat
Jump_NIO_Mode
Explanation
Non-localised name of the test step.
Localised name of the test step.
Short name of the test step.
Indicates whether the test step is to be carried out. The value is always
true
. The value is reserved for future purposes.
The result valuation IO and NIO is replaced. This field is only used for dummy tests.
Indicates whether the test step is to be displayed. The value is reserved for future purposes.
Indicates how the jump is to be carried out in the event of an IO event of the test step.
0 -> Next step
1 -> Go to the end
2 -> Go to a jump destination
Indicates the jump destination in the event of an IO result of the test step.
Indicates how often the test step is to be repeated in the event of an IO result of the test step. This value is always 0.
Indicates how the jump is to be carried out in the event of an NIO event of the test step.
User Manual ATS400 Version 3.14.41 - 1 166
Report creation
Key word
Jump_NIO_Jump
Jump_NIO_Repeat
Jump_Error_Mode
Jump_Error_Jump
Jump_Error_Repeat
Jump_Cancel_Mode
Jump_Cancel_Jump
Jump_Cancel_Repeat
TestStep
Explanation
0 -> Next step
1 -> Go to the end
2 -> Go to a jump destination
Indicates the jump destination in the event of an NIO result of the test step.
Indicates how often the test step is to be repeated in the event of an NIO result of the test step.
Indicates how the jump is to be carried out in the event of an error of the test step.
0 -> Next step
1 -> Go to the end
2 -> Go to a jump destination
This value is always 1.
Indicates the jump destination in the event of an error of the test step.
Indicates how often the test step is to be repeated in the event of an error of the test step. This value is always 0.
Indicates how the jump is to be carried out in the event of a cancellation of the test step.
0 -> Next step
1 -> Go to the end
2 -> Go to a jump destination
Indicates the jump destination in the event of a cancellation of the test step.
Indicates how often the test step is to be repeated in the event of a cancellation of the test step. This value is always 0.
Sequential number of the step.
5.1.2
HTML templates
HTML templates can be created and edited with any program that is able to save in the file type. Depending on the program, you must observe corresponding framework conditions.
Problematic in this context is that some programmes break down the key words into parts when editing them and insert formatting instructions. In this case, the key word is no longer identified.
User Manual ATS400 Version 3.14.41 - 1 167
Report creation
Use the HTML template; for the
Printer
or
Save as PDF
report option, the settings of the local Internet Explorer and of the printer are also required. The header and footer can be configured in the
Internet Explorer
in the
Page Setup
dialogue. The settings for the side orientation and paper size are made in the printer. The side edges must be set in the registration database with the
RegEdit
program from
Microsoft
Windows
.
Creation with Microsoft Word 2010
Creation with Open Office Writer
5.1.2.1 Creation with Microsoft Word 2012
Create a new empty document or use a template already created by you.
Save this document with
Save as
as a
Website, filtered (*.htm;*.html)
oder
website (*.htm;*.html)
. Note that you must edit the extension suggested from
htm
to
html
after setting all options.
User Manual ATS400 Version 3.14.41 - 1 168
Report creation
Under
Tools
open the dialogue
Web options...
.
In the
Browser
tab, deactivate the
Save new websites as websites in a file
option.
User Manual ATS400 Version 3.14.41 - 1 169
Report creation
In the
Files
tab, activate the
Save help files in a folder
option.
In the
Coding
tab, select from the
Save document as
selection the
Unicode (UTF8)
entry.
If you have selected
Website, filtered (*.htm;*.html)
you are given the
User Manual ATS400 Version 3.14.41 - 1 170
Report creation
following warning. Click on the
Yes
button.
Create your report.
If you save the report, you are given a file and a folder. The help files can be found in the folder. If you need to copy or move the template, you always also need to copy or move the folder with it.
User Manual ATS400 Version 3.14.41 - 1 171
Report creation
5.1.3
CSV templates
CSV is a text-based table format. You can edit it with every text editor or with most table calculations. If you do not use Microsoft Excel, it must be ensured that ISO-
8859-15 is used as the character coding. If you create CSV files with the
ATS400 X4
or
ATS400 X5
device variants, it must be a 7-bit ASCII, which means that the illustration is compatible. In this case, no umlauts may be used.
Creation with Microsoft Excel 2010
Creation with Open Office Calc
User Manual ATS400 Version 3.14.41 - 1 172
Report creation
5.1.3.1 Creation with Microsoft Excel 2010
Create a new empty document or use a template already created by you.
Delete all worksheets except for the first one.
Save this document using
Save as
as a
CSV (separator-separated) (*.csv)
.
User Manual ATS400 Version 3.14.41 - 1 173
Report creation
Create your report.
When saving, information is displayed to you. Click on the
Ok
button to save.
User Manual ATS400 Version 3.14.41 - 1 174
Report creation
User Manual ATS400 Version 3.14.41 - 1 175
Reference
6 Reference
This area describes all files used by
ETL DataView 3
that are managed or created within
ETL DataView 3
.
6.1
Patterns
At various places in the configuration patterns can be used. This patterns are used similar to regular expressions .
A pattern consists of characters which have a special meaning. The following patterns are defined:
c t r a
C Description h a e r
? one character, e. g. A
*a string, e. g. Text
Aa letter (a-z, A-Z)
0a cipher (0-9)
Wan alphanumerical letter (a-z, A-Z, 0-9, _)
\ exact this character, e. g. \W at tis place a W is expected
( Extract the enclosed characters. Is used in the automatic test plan selection. It is
) not allowed to nest parantheses into each other.
Examples:
t e r n
P Description a t
0 It is expected to enter 6 ciphers, e. g. 202201
0
User Manual ATS400 Version 3.14.41 - 1 176
Reference t e r n
P Description a t
0
0
0
0
0
0
0
\
0
0
0 It is expected to enter 4 ciphers, a space and 4 ciphers, e. g. 0112 1000
0
0
0
0
0
\
0
0
0
0
\
0
0
0
0
0
0 It is expected to enter 6 ciphers, a space, 4 ciphers, a space and 4 ciphers, e. g.
0
202201 0112 1000
0
0
A It is expected to enter 3 letters and two ciphers , e. g. Typ25
A
A
6.2
Protective earth test
The PE-measurement is realized int 4-wire technic. This means that the measurement cables have different wires for the current (source) and the voltage measurement
(sense). These are connected together directly at the measurement point. Therefore the resistance of the measurement cable does not influence the result. This is true only for the effective resistance of the measurement cable but not for the inductivity and the resulting apperent resistance. Especially with small test resistance and
User Manual ATS400 Version 3.14.41 - 1 177
Reference
unfavourable installation could this lead to measure an increased resistance.
The resistance of the unit under test is normally a effective resistance. Errors resulting from the inductivity of the measurement cables will decrease with higer resistance of the unit under test. An apperent resistance of 10 mΩ for the measurement cable and
10 mΩ for the unit under test results in a measurement of 14 mΩ. With a unit under test of 50 mΩ the result will be 51 mΩ and with 100 mΩ it will be 100,5 mΩ.
In the case the inductivity of the measurement cable is disturbant the inductivity should be kept small. To achive this keep the aerea between the measurement cables small.
Additonally you must take care of a sufficent contact pressure to keep the contact resistance small.
6.2.1
Leading of the cable
Some examples for leading of the wires.
User Manual ATS400 Version 3.14.41 - 1 178
Reference
Unfavourable leading of the measurement cable. A large aerea is spanned between the both measurement cables and therefore the apperant resistance will increase.
Also unfavourable leading of the measurement cables. The aerea between the measurement cables is smaller but the apperant resistance will increase due to the loop.
Favourable leading of the measurement wires. The aerea between the measurement cables is small keeping the apperant resistane small.
User Manual ATS400 Version 3.14.41 - 1 179
Reference
6.3
High voltage test
For the
ATS400
three groups of high voltage test modules are offered. These will be named in the following with there short names. The short name HVDC will be used if the text is valid for the HVDC7 and HVDC3 module.
Short name
HVAC
HVDC7
HVDC3
Module
Test with alternate current.
Test with direct current. These modules have a testing voltage of 5 KV or more.
Test with direct current. These modules have a testing voltage up to 3600 Volt and are current limited.
Informations for configuration of the high voltage test you will find for
HVDC7-Test and the HVDC3-Test in the part
.
6.3.1
Evaluation of the measurement
6.3.1.1 Error messages for high voltage AC
Value
19
20
21
22
0
16
17
18
23
24
25
Description
No error
Upper current limit exceeded.
Break through deteced with peak current.
Testing voltage not reached.
Lower current limit not reached.
Break through in ramp. Limit for spark detection exceeded.
Upper current during ramp exceeded.
Break through during static phase. Limit for spark detection exceeded.
Upper current limit during static phase exceeded.
Break through in ramp. Gradient for spark detection exceeded.
Break through during static phase. Gradient for spark detection exceeded.
6.3.1.2 Error messages for high voltage DC
Value
0
32
33
Description
No error
Upper current limit exceeded.
Break through deteced with peak current.
User Manual ATS400 Version 3.14.41 - 1 180
Reference
Value
34
35
36
37
38
39
40
41
42
Description
Lower current limit not reached.
Break through.
Testing voltage not reached.
Break through in ramp. Limit for spark detection exceeded.
Upper current during ramp exceeded.
Break through during static phase. Limit for spark detection exceeded.
Upper current limit during static phase exceeded.
Break through in ramp. Gradient for spark detection exceeded.
Break through during static phase. Gradient for spark detection exceeded.
6.3.1.3 Test for required voltage
After powering on resp. at the end of the ramp when the current voltage does not change any more it is checked that the current voltage has reached more than 95% of the voltage in parameter
Test voltage
.
6.3.1.4 Current error at upper limit
This error will be detected when the measured current exceeds the current in parameter
Maximum Current
.
This evaluation will be done in the following cases:
Phase
Rising ramp
Static
Falling ramp
HVAC
Yes
Yes
Yes
HVDC
No
Yes
No
6.4
Results files
The results files have the extension
.result
. The place of saving and the file name result from the details in
Settings
->
File storage
->
Result
. This file has the format of an XML file with UTF-8 coding with BOM.
<ResultData>
is the enclosing tag.
contains the list of test steps.
<ResultData>/<TestSteps>/<TestStep Index="n">
number in
Index
is incremented for every test step.
contains the overall result as well as the data of the
User Manual ATS400 Version 3.14.41 - 1 181
Reference
automatic test plan selection.
contains the options of the test plan.
<ResultData>/PlanOptionen>/<ReportOptionen>
contains the list of reports to be
created.
<ResultData>/PlanOptionen>/<ReportOptionen>/<ReportOption>
report settings for a report.
6.4.1
Header
The data in this block can be found under
<ResultData>/<Header>
.
Tag
DataView_Version
TestPlan_Version
PlanName
PlanPath
PlanDescription
Explanation
Version of
ETL DataView 3
with which this file was created.
Version of the format of the file.
Name of the test plan, is filled with the file name when being created.
Relative path to the application where the test plan was saved.
Description of the test plan. This value can be entered by the user in
Settings
->
Text
.
PlanCreatedByUse
r User who created the test plan first. If user administration is not active, the field is empty.
PlanCreatedByWorkstation
Test station where the test plan was created. The name of the test station can be stated in
Settings
-
>
Workstation
->
Base settings
.
PlanCreatedOnDate
PlanEditedByUser
PlanEditedByWorkstation
PlanEditedOnDate
FileSavedByUser
FileSavedByWorkstation
Date of creating the test plan. The date is in the format in accordance with the country settings valid at this moment in time.
User who modified the test plan last. If user administration is not active, the field is empty.
Test station where the test plan was modified last.
The name of the test station can be stated in
Settings
->
Workstation
->
Base settings
.
Date of modifying the test plan. The date is in the format in accordance with the country settings valid at this moment in time.
User who saved the test plan or the result file.
Test station where the test plan or the result file was saved. The name of the test station can be stated in
Settings
->
Workstation
->
Base settings
.
FileSavedOnDate
Date of saving the test plan or the result file. The date is in the format in accordance with the country
User Manual ATS400 Version 3.14.41 - 1 182
Reference
Tag Explanation
settings valid at this moment in time.
PlanIdentificationEnabled
The
<ResultData>\<Identification>
block exists.
PlanBatchEnabled
PlanTestSteps
Intended for future purposes.
Number of test steps in the test plan.
6.4.2
Identification
The data in this block can be found under
<ResultData>/<Identification>
.
Tag
IDs
ID_n
Explanation
Number of IDs.
Identification for the test plan. The tags are numbered from 0 to the number of IDs - 1, i.e. have the values
ID_0, ID_1, etc.
6.4.3
Teststeps
The data in this block can be found under
<ResultData>/<TestSteps>
.
This block contains a list of the individual test steps. Every test step is a
own.
6.4.3.1 TestStep
The data in this block can be found under
<ResultData>/<TestSteps>/<TestStep
Index="n">
.
Attribute
Index
Explanation
Index of the test step, counting starts from 0
Tag
Test
TestName
Execute
InvertResult
View
Parameter
Explanation
ID of the test type
Non-localised name of the test step.
Indicates whether the test step is to be carried out.
The value is always
true
. The value is reserved for future purposes.
The result valuation IO and NIO is replaced. This field is only used for dummy tests.
Indicates whether the test step is to be displayed. The value is reserved for future purposes.
Number of parameters of this test step. The number of parameters depends on the test step.
User Manual ATS400 Version 3.14.41 - 1 183
Reference
Tag
Parameter_n
Jump
Jump_IO_Mode
Jump_IO_Jump
Jump_IO_Repeat
Jump_NIO_Mode
Jump_NIO_Jump
Jump_NIO_Repeat
Jump_Error_Mode
Jump_Error_Jump
Jump_Error_Repeat
Jump_Cancel_Mode
Jump_Cancel_Jump
Jump_Cancel_Repeat
Text
Explanation
Parameter of the test step. These parameters are explained individually for every test type.
This fields always has the value
Jump
.
Indicates how the jump is to be carried out in the event of an IO event of the test step.
0 -> Next step
1 -> Go to the end
2 -> Go to a jump destination
Indicates the jump destination in the event of an IO result of the test step.
Indicates how often the test step is to be repeated in the event of an IO result of the test step. This value is always 0.
Indicates how the jump is to be carried out in the event of an NIO event of the test step.
0 -> Next step
1 -> Go to the end
2 -> Go to a jump destination
Indicates the jump destination in the event of an NIO result of the test step.
Indicates how often the test step is to be repeated in the event of an NIO result of the test step.
Indicates how the jump is to be carried out in the event of an error of the test step.
0 -> Next step
1 -> Go to the end
2 -> Go to a jump destination
This value is always 1.
Indicates the jump destination in the event of an error of the test step.
Indicates how often the test step is to be repeated in the event of an error of the test step. This value is always 0.
Indicates how the jump is to be carried out in the event of a cancellation of the test step.
0 -> Next step
1 -> Go to the end
2 -> Go to a jump destination
Indicates the jump destination in the event of a cancellation of the test step.
Indicates how often the test step is to be repeated in the event of a cancellation of the test step. This value is always 0.
Immer 3.
User Manual ATS400 Version 3.14.41 - 1 184
Reference
Tag
Text_0
TextEnable_0
TextSize_0
Picture_0
Outputtype_0
OutputSize_0
Text_1
TextEnable_1
TextSize_1
Picture_1
Outputtype_1
OutputSize_1
Explanation
Text to be output with indication beforehand.
Activation of the output with indication beforehand.
Font size with indication beforehand.
File name of the image with indication beforehand.
If the file can be reached via a relative path from the folder of the plan files, the relative path is entered, otherwise the absolute path is entered.
Image or text display with indication beforehand.
Values used:
Text
displays the text only.
Bild
displays the image only.
TextBild
displays the text and the image.
TextWithInputField
displays the text and an input field.
Small or large display with indication beforehand
Values used:
TextKlein
displays the small window for the text.
TextGroß
displays the large window for the text.
BildKlein
displays the small window with the image.
BildGroß
displays the large window with the image.
TextMitEingabeFeldKlein
displays the small window for the text and the input field.
TextMitEingabeFeldGroß
displays the large window for the text and the input field.
Nichts
displays no field.
Text to be output with indication during.
Activation of the output with indication during.
Font size with indication during.
File name of the image with indication during.
If the file can be reached via a relative path from the folder of the plan files, the relative path is entered, otherwise the absolute path is entered.
Image or text display with indication during
Values used:
Text
displays the text only.
Bild
displays the image only.
TextBild
displays the text and the image.
TextWithInputField
displays the text and an input field.
Small or large display with indication during.
Values used:
TextKlein
displays the small window for the text.
TextGroß
displays the large window for the text.
BildKlein
displays the small window with the image.
User Manual ATS400 Version 3.14.41 - 1 185
Reference
Tag
Text_2
TextEnable_2
TextSize_2
Picture_2
Outputtype_2
OutputSize_2
Tags
TagName_n
TagData_n
Template
Show
Size
Explanation
BildGroß
displays the large window with the image.
TextMitEingabeFeldKlein
displays the small window for the text and the input field.
TextMitEingabeFeldGroß
displays the large window for the text and the input field.
Nichts
displays no field.
Text to be issued in the event of error.
Activation of the output in the event of an error.
Font size in the event of an error.
File name of the image in the event of an error.
If the file can be reached via a relative path from the folder of the plan files, the relative path is entered, otherwise the absolute path is entered.
Image or text display in the event of an error.
Values used:
Text
displays the text only.
Bild
displays the image only.
TextBild
displays the text and the image.
TextWithInputField
displays the text and an input field.
Small or large display in the event of an error.
Values used:
TextKlein
displays the small window for the text.
TextGroß
displays the large window for the text.
BildKlein
displays the small window with the image.
BildGroß
displays the large window with the image.
TextMitEingabeFeldKlein
displays the small window for the text and the input field.
TextMitEingabeFeldGroß
displays the large window for the text and the input field.
Nichts
displays no field.
Number of the field names of the test step. This value is
0, except for the batch and data input test steps.
Name of the field. The
n
postfix corresponds to the number of the field counted from 0. This entry only exists if
Tags
is not equal to 0.
Pre-occupation or sample of the field. The
n
postfix corresponds to the number of the field counted from 0.
This entry only exists if
Tags
is not equal to 0.
Outdated, is no longer used.
Indicates whether a user notice is displayed before the multiple test.
Font size of the text for a multiple test.
User Manual ATS400 Version 3.14.41 - 1 186
Reference
Tag
Text
Display
PicturePath
StepCycleTime
Count_Tests
Count_IO
Count_NIO
Count_ERROR
Result
ResultValue_1
ResultValue_2
TestTime
Error
Explanation
Text to be issued in the event of a multiple test.
Image or text display in the event of a multiple test.
Values used:
Text
displays the text only.
Bild
displays the image only.
TextBild
displays the text and the image.
TextWithInputField
displays the text and an input field.
File name of the image in the event of a multiple test.
If the file can be reached via a relative path from the folder of the plan files, the relative path is entered, otherwise the absolute path is entered.
Duration of the test.
Total number of tests carried out.
Number of times this step was successfully carried out.
Number of times not carried out successfully.
Number of cancelled tests.
Result of the test step:
UnTested
-> This test step was not carried out during this test.
Active
-> Test step is active, cannot occur in the file.
IO
-> This test step was rated as IO.
NIO
-> This test step was rated as NIO.
ERROR
-> This test step was cancelled with an error.
Jumped
-> This test step was skipped.
Numeric measurement value in SI unit.
Numeric value of the test size in SI units.
Formatted duration of the test in seconds.
Indication of the error when cancelling the measurement.
None
-> No error
Timeout_StartMeasurement
-> Time error when starting the measurement
Timeout_SetPassFail
-> not used
Timeout_MeasureTimeOvershoot
-> measurement time exceeded
Invalid_TestState
-> invalid test status
Invalid_TestResult
-> invalid test result
Invalid_PVSteuerLT
-> invalid control word
Invalid_PVStatusPruefung
-> invalid status of the test
Invalid_TestParameter
-> invalid test parameter
Cancel
-> cancelled
User Manual ATS400 Version 3.14.41 - 1 187
Reference
Tag Explanation
ErrorInfo
TestPoint_n
TestingUser
SightCheckInputText
MultitestUser_n
Expanded error number.
User input for the multitest.
The
n
post fix is counted upwards from 0.
User loged in during the test step.
User entry during the visual inspection.
User loged in during the multitest.
The
n
post fix is counted upwards from 0.
6.4.3.1.1 Protective Earth
Parameters of the
Protective Earth
test step.
Tag
Parameter_0
Parameter_1
Parameter_2
Parameter_3
Parameter_4
Parameter_5
Parameter_6
Parameter_7
Parameter_8
Parameter_9
Parameter_10
Parameter_11
bis
Parameter_26
Parameter
StartCondition
U
I
StartConditionMas k
R_max t t_delay f t_start
EN60204
Polung
PolungCAN_00
PolungCan_15
bis
Explanation
Start conditions of the test step. The start conditions are saved in a bit-coded manner and can only be analysed together with the
StartConditionMask
field.
Start conditions of the test step. The start conditions are saved in a bit-coded manner and can only be analysed together with the
StartCondition
field.
Idle voltage
Test current
Upper threshold value of the resistance.
Test time
Start delay between fulfilling the start condition and the start of the test.
Frequency of the voltage
Delay time for the start scenario when starting the test until starting the analysis. This value is not valid for all start scenarios.
Indication whether the test is performed in accordance with EN 60204.
Always 0.
Contacting setting of an external relay matrix.
Setting of the relay matrix in accordance with the choice in the program. The
User Manual ATS400 Version 3.14.41 - 1 188
Reference
Tag
Parameter_27
Parameter_28
Parameter_29
Parameter_30
Parameter_31
Parameter_32
Parameter_33
Parameter_34
Parameter_35
Parameter_36
Parameter_37
Parameter_38
Parameter_39
Parameter_40
Parameter_41
Parameter_42
Parameter_43
Parameter Explanation
StateChangeBits
display is bit coded.
Always 0, never used.
Multitest_Enable
Multitest is active, if the value does not equal 0.
Multitest_Auswert ung
Multitest_Endekri terium
Method of analysing the multitest.
0 = worst measurement value.
Method of ending the multitest.
0 = number of measurements
1 = pass key
Number of multitest inspections.
Multitest_Endekri terium_Anzahl
ErrorStartConditi on
ErrorStartConditi onMask
Condition for switching forward in the event of an error.
Mask for the condition for switching further in the event of an error.
Always 0, never used.
ErrorStateChangeB its
ErrorWSBDelay
Delay of switching further in the event of an error.
ErrorWSBTimeValid
Delay time active.
StartStateChange
Indicates whether the switching condition needs to be maintained when testing the start conditions.
0 = no waiting for switch condition
1 = Wait for switching condition
DC_Enable
Indicates whether the test is carried out with direct current voltage.
0: Alternating current
1: Direct current
StartStateJump
Indicates whether the
Jump
button is displayed.
Repeating
StartButton
PassButton
StartandJump
Indicates how often the test step is carried out.
Indicates whether the
Start
button is displayed.
Indicates whether the
Pass
button is displayed.
Indicates whether the
Start
and
Jump
buttons are displayed.
User Manual ATS400 Version 3.14.41 - 1 189
Reference
Tag
Parameter_44
Parameter_45
Parameter_46
Parameter_47
Parameter_48
Parameter
StartTime_Delay
Explanation
Wait time for the signal
Start-Button
, in case the start condition is
monitored
.
StartPETime_Delay
Wait time for the signal
Contact
Monitoring
, in case the start condition is
monitored
.
StartKUTime_Delay
Wait time for the signal
Contact
Monitoring
, in case the start condition is
monitored
.
StartSHKHVTime_De lay
Wait time for the signal
Safety Circuit
HV
, in case the start condition is
monitored
.
PassButtonVisible
Indicates whether the button
Pass
will be shown during a Multitest.
6.4.3.1.2 High voltage AC
Parameters of the
High voltage AC
test step.
Tag
Parameter_0
Parameter_1
Parameter_2
Parameter_3
Parameter_4
Parameter_5
Parameter_6
Parameter_7
Parameter_8
Parameter_9
Parameter_10
Parameter
StartCondition
StartConditionMas k
U
I_min
I_max t t_delay
Ramp
U_start t_up t_down
Explanation
Start conditions of the test step. The start conditions are saved in a bit-coded manner and can only be analysed together with the
StartConditionMask
field.
Start conditions of the test step. The start conditions are saved in a bit-coded manner and can only be analysed together with the
StartCondition
field.
Test voltage
Lower threshold
Upper threshold
Test duration
Start delay between fulfilling the start condition and the start of the test.
Indicates whether the ramp is active.
Start voltage
Increase time of the ramp. This parameter is only valid if the ramp is active.
Drop time of the ramp. This parameter is only valid if the ramp is active.
User Manual ATS400 Version 3.14.41 - 1 190
Reference
Tag
Parameter_11
Parameter_12
Parameter_13
Parameter_14
bis
Parameter_29
Parameter_30
Parameter_31
Parameter Explanation f t_start
Polung
PolungCAN_00
PolungCan_15
bis
StateChangeBits
Frequency of the voltage
Delay time for the start scenario when starting the test until starting the analysis. This value is not valid for all start scenarios.
Contacting setting of an external relay matrix.
Setting of the relay matrix in accordance with the choice in the program. The display is bit coded.
Always 0, never used.
Multitest_Enable
Multitest is active, if the value does not equal 0.
Parameter_32
Parameter_33
Parameter_34
Parameter_35
Parameter_36
Parameter_37
Parameter_38
Parameter_39
Parameter_40
Parameter_41
Parameter_42
Parameter_43
Multitest_Auswert ung
Multitest_Endekri terium
Method of analysing the multitest.
0 = worst measurement value.
Method of ending the multitest.
0 = number of measurements
1 = pass key
Number of multitest inspections.
Multitest_Endekri terium_Anzahl
Offset
ErrorStartConditi on
ErrorStartConditi onMask
Always 0, will not be used.
Condition for switching forward in the event of an error.
Mask for the condition for switching further in the event of an error.
Always 0, never used.
ErrorStateChangeB its
ErrorWSBDelay
Delay of switching further in the event of an error.
ErrorWSBTimeValid
Delay time active.
StartStateChange
Indicates whether the switching condition needs to be maintained when testing the start conditions.
0 = no waiting for switch condition
1 = Wait for switching condition
Quelle
Selected current source.
This parameter is only used in the event of a hot high voltage.
f_Source
Frequency of the source.
This parameter is only used in the event of a hot high voltage.
User Manual ATS400 Version 3.14.41 - 1 191
Reference
Tag
Parameter_44
Parameter_45
Parameter_46
Parameter_47
Parameter_48
Parameter_49
Parameter_50
Parameter_51
Parameter_52
Parameter_53
Parameter_54
Parameter_55
Parameter_56
Parameter_57
Parameter_58
Parameter
U_Source
StartStateJump
Explanation
Voltage of the source.
This parameter is only used in the event of a hot high voltage.
Indicates whether the
Jump
button is displayed.
Management
Auswertung
Repeating
StartButton
PassButton
StartandJump
StartandJump
CreateLog
Timeinterval
Indicates how the supply of the test item is to be carried out.
0: Power off after test
1: Keep power on after test
2: Only power off
3: Power off only on error
4: Only power on
Type of the analysis of the test.
0 = end the test time
1 = end with start signal
Indicates how often the test step is carried out.
Indicates whether the
Start
button is displayed.
Indicates whether the
Pass
button is displayed.
Indicates whether the
Start
and
Jump
buttons are displayed.
Indicates whether the
Start
and
Jump
buttons are displayed.
Indicates whether a log file will be created.
0 = No log file will be created
1 = A log file be created
Time interval between two samples which will be written to the log file. The value is in seconds.
This value will only be used in case the value in
CreateLog
is 1.
StartTime_Delay
Wait time for the signal
Start-Button
, in case the start condition is
monitored
.
StartPETime_Delay
Wait time for the signal
PE-Testprobe
, in case the start condition is
monitored
.
StartKUTime_Delay
Wait time for the signal
Contact
Monitoring
, in case the start condition is
monitored
.
StartSHKHVTime_De
Wait time for the signal
Safety Circuit
User Manual ATS400 Version 3.14.41 - 1 192
Reference
Tag
Parameter_59
Parameter_60
Parameter_61
Parameter lay
Explanation
HV
, in case the start condition is
monitored
.
PassButtonVisible
Indicates whether the button
Pass
will be shown during a Multitest.
SparkDetection
ContinousRamp
This parameter is only valid on deivices with HVdc7/8 module and a HMP supporting spark detection.
Setting of the spark detection.
0 = Off
1 = Coarse
2 = Normal
3 = Fine
Indicates that the rampe will be continued after the test step.
This parameter is only valid for the variant for KWP protocol and high voltage tester of Series 36.
0: Ramp will not be continued
1: Ramp will be continued
6.4.3.1.3 High voltage DC
Parameters of the
High voltage DC
test step.
Tag
Parameter_0
Parameter_1
Parameter_2
Parameter_3
Parameter_4
Parameter_5
Parameter_6
Parameter_7
Parameter_8
Parameter_9
Parameter
StartCondition
StartConditionMas k
U
I_min
I_max t t_delay
Ramp
U_start t_up
Explanation
Start conditions of the test step. The start conditions are saved in a bit-coded manner and can only be analysed together with the
StartConditionMask
field.
Start conditions of the test step. The start conditions are saved in a bit-coded manner and can only be analysed together with the
StartCondition
field.
Test voltage
Lower threshold
Upper threshold
Test duration
Start delay between fulfilling the start condition and the start of the test.
Indicates whether the ramp is active.
Start voltage
Increase time of the ramp. This
User Manual ATS400 Version 3.14.41 - 1 193
Reference
Tag
Parameter_10
Parameter_11
Parameter_12
Parameter_13
Parameter_14
bis
Parameter_29
Parameter_30
Parameter_31
Parameter Explanation t_down t_start
parameter is only valid if the ramp is active.
Drop time of the ramp. This parameter is only valid if the ramp is active.
Delay time for the start scenario when starting the test until starting the analysis. This value is not valid for all start scenarios.
U_discharge
Polung
PolungCAN_00
PolungCan_15
bis
StateChangeBits
Discharge voltage
Contacting setting of an external relay matrix.
Setting of the relay matrix in accordance with the choice in the program. The display is bit coded.
Always 0, never used.
Multitest_Enable
Multitest is active, if the value does not equal 0.
Parameter_32
Parameter_33
Parameter_34
Parameter_35
Parameter_36
Parameter_37
Parameter_38
Parameter_39
Parameter_40
Parameter_41
Multitest_Auswert ung
Multitest_Endekri terium
Method of analysing the multitest.
0 = worst measurement value.
Method of ending the multitest.
0 = number of measurements
1 = pass key
Number of multitest inspections.
Multitest_Endekri terium_Anzahl
ErrorStartConditi on
ErrorStartConditi onMask
Condition for switching forward in the event of an error.
Mask for the condition for switching further in the event of an error.
Always 0, never used.
ErrorStateChangeB its
ErrorWSBDelay
Delay of switching further in the event of an error.
ErrorWSBTimeValid
Delay time active.
StartStateChange
Indicates whether the switching condition needs to be maintained when testing the start conditions.
0 = no waiting for switch condition
1 = Wait for switching condition
Quelle
Selected current source.
This parameter is only used in the event of a hot high voltage.
User Manual ATS400 Version 3.14.41 - 1 194
Reference
Tag
Parameter_42
Parameter_43
Parameter_44
Parameter_45
Parameter_46
Parameter_47
Parameter_48
Parameter_49
Parameter_50
Parameter_51
Parameter_52
Parameter_53
Parameter_54
Parameter_55
Parameter f_Source
U_Source
StartStateJump
Explanation
Frequency of the source.
This parameter is only used in the event of a hot high voltage.
Voltage of the source.
This parameter is only used in the event of a hot high voltage.
Indicates whether the
Jump
button is displayed.
Management
Auswertung
Repeating
StartButton
PassButton
StartandJump
CreateLog
Timeinterval
Indicates how the supply of the test item is to be carried out.
0: Power off after test
1: Keep power on after test
2: Only power off
3: Power off only on error
4: Only power on
Type of the analysis of the test.
0 = end the test time
1 = end with start signal
Indicates how often the test step is carried out.
Indicates whether the
Start
button is displayed.
Indicates whether the
Pass
button is displayed.
Indicates whether the
Start
and
Jump
buttons are displayed.
Indicates whether a log file will be created.
0 = No log file will be created
1 = A log file be created
Time interval between two samples which will be written to the log file. The value is in seconds.
This value will only be used in case the value in
CreateLog
is 1.
StartTime_Delay
Wait time for the signal
Start-Button
, in case the start condition is
monitored
.
StartPETime_Delay
Wait time for the signal
PE-Testprobe
, in case the start condition is
monitored
.
StartKUTime_Delay
Wait time for the signal
Contact
Monitoring
, in case the start condition is
monitored
.
User Manual ATS400 Version 3.14.41 - 1 195
Reference
Tag
Parameter_56
Parameter_57
Parameter_58
Parameter_59
Parameter
StartSHKHVTime_De lay
Explanation
Wait time for the signal
Safety Circuit
HV
, in case the start condition is
monitored
.
PassButtonVisible
Indicates whether the button
Pass
will be shown during a Multitest.
SparkDetection
ContinousRamp
This parameter is only valid on deivices with HVdc7/8 module and a HMP supporting spark detection.
Setting of the spark detection.
0 = Off
1 = Coarse
2 = Normal
3 = Fine
Indicates that the rampe will be continued after the test step.
This parameter is only valid for the variant for KWP protocol and high voltage tester of Series 36.
0: Ramp will not be continued
1: Ramp will be continued
6.4.3.1.4 Insulation
Parameters of the
Insulation
test step.
Tag
Parameter_0
Parameter_1
Parameter_2
Parameter_3
Parameter_4
Parameter_5
Parameter_6
Parameter_7
Parameter_8
Parameter
StartCondition
StartConditionMas k
U
R_min t t_delay
Ramp
U_start t_up
Explanation
Start conditions of the test step. The start conditions are saved in a bit-coded manner and can only be analysed together with the
StartConditionMask
field.
Start conditions of the test step. The start conditions are saved in a bit-coded manner and can only be analysed together with the
StartCondition
field.
Test voltage
Lower threshold of the insulation resistance.
Test duration
Start delay between fulfilling the start condition and the start of the test.
Indicates whether the ramp is active.
Start voltage
Increase time of the ramp. This
User Manual ATS400 Version 3.14.41 - 1 196
Reference
Tag
Parameter_9
Parameter_10
Parameter_11
Parameter_12
Parameter_13
bis
Parameter_28
Parameter_29
Parameter_30
Parameter Explanation t_down t_start
parameter is only valid if the ramp is active.
Drop time of the ramp. This parameter is only valid if the ramp is active.
Delay time for the start scenario when starting the test until starting the analysis. This value is not valid for all start scenarios.
U_discharge
Polung
PolungCAN_00
PolungCan_15
bis
StateChangeBits
Discharge voltage
Contacting setting of an external relay matrix.
Setting of the relay matrix in accordance with the choice in the program. The display is bit coded.
Always 0, never used.
Multitest_Enable
Multitest is active, if the value does not equal 0.
Parameter_31
Parameter_32
Parameter_33
Parameter_34
Parameter_35
Parameter_36
Parameter_37
Parameter_38
Parameter_39
Parameter_40
Multitest_Auswert ung
Multitest_Endekri terium
Method of analysing the multitest.
0 = worst measurement value.
Method of ending the multitest.
0 = number of measurements
1 = pass key
Number of multitest inspections.
Multitest_Endekri terium_Anzahl
ErrorStartConditi on
ErrorStartConditi onMask
Condition for switching forward in the event of an error.
Mask for the condition for switching further in the event of an error.
Always 0, never used.
ErrorStateChangeB its
ErrorWSBDelay
Delay of switching further in the event of an error.
ErrorWSBTimeValid
Delay time active.
StartStateChange
Indicates whether the switching condition needs to be maintained when testing the start conditions.
0 = no waiting for switch condition
1 = Wait for switching condition
Quelle
Selected current source.
This parameter is only used in the event of a hot high voltage.
User Manual ATS400 Version 3.14.41 - 1 197
Reference
Tag
Parameter_41
Parameter_42
Parameter_43
Parameter_44
Parameter_45
Parameter_46
Parameter_47
Parameter_48
Parameter_49
Parameter_50
Parameter_51
Parameter_52
Parameter_53
Parameter_54
Parameter f_Source
U_Source
StartStateJump
Explanation
Frequency of the source.
This parameter is only used in the event of a hot high voltage.
Voltage of the source.
This parameter is only used in the event of a hot high voltage.
Indicates whether the
Jump
button is displayed.
Management
Auswertung
Repeating
StartButton
PassButton
StartandJump
CreateLog
Timeinterval
Indicates how the supply of the test item is to be carried out.
0: Power off after test
1: Keep power on after test
2: Only power off
3: Power off only on error
4: Only power on
Type of the analysis of the test.
0 = end the test time
1 = end with start signal
Indicates how often the test step is carried out.
Indicates whether the
Start
button is displayed.
Indicates whether the
Pass
button is displayed.
Indicates whether the
Start
and
Jump
buttons are displayed.
Indicates whether a log file will be created.
0 = No log file will be created
1 = A log file be created
Time interval between two samples which will be written to the log file. The value is in seconds.
This value will only be used in case the value in
CreateLog
is 1.
StartTime_Delay
Wait time for the signal
Start-Button
, in case the start condition is
monitored
.
StartPETime_Delay
Wait time for the signal
PE-Testprobe
, in case the start condition is
monitored
.
StartKUTime_Delay
Wait time for the signal
Contact
Monitoring
, in case the start condition is
monitored
.
User Manual ATS400 Version 3.14.41 - 1 198
Reference
Tag
Parameter_55
Parameter_56
Parameter
StartSHKHVTime_De lay
Explanation
Wait time for the signal
Safety Circuit
HV
, in case the start condition is
monitored
.
PassButtonVisible
Indicates whether the button
Pass
will be shown during a Multitest.
6.4.3.1.5 FCT-Current
Parameters of the
FCT-Current
test step.
Tag
Parameter_0
Parameter_1
Parameter_2
Parameter_3
Parameter_4
Parameter_5
Parameter_6
Parameter_7
Parameter_8
Parameter_9
Parameter_10
Parameter_11
Parameter
StartCondition
StartConditionMas k
U_Source
U
I_min
I_max t t_delay f t_start t_timeout
Gradient
Explanation
Start conditions of the test step. The start conditions are saved in a bit-coded manner and can only be analysed together with the
StartConditionMask
field.
Start conditions of the test step. The start conditions are saved in a bit-coded manner and can only be analysed together with the
StartCondition
field.
Source of the test supply.
Voltage of the test item supply
Lower threshold value during the analysis. Not valid if the analysis is set to
Pass/Fail
. The unit and thresholds depend on the channel.
Upper threshold value during the analysis. Not valid if the analysis is set to
Pass/Fail
. The unit and thresholds depend on the channel.
Test time
Start delay between fulfilling the start condition and the start of the test.
Frequency of the voltage
Delay time for the start scenario when starting the test until starting the analysis. This value is not valid for all start scenarios.
Timeout for the start of the analysis.
The value is not used for all start scenarios.
Gradient for the start of the analysis.
This value is not used for all start
User Manual ATS400 Version 3.14.41 - 1 199
Reference
Tag
Parameter_12
Parameter_13
Parameter_14
Parameter_15
bis
Parameter_30
Parameter_31
Parameter_32
Parameter_33
Parameter
Management
Scenario
Polung
PolungCAN_00
PolungCan_15
Auswertung
bis
Explanation
scenarios.
Indicates how the supply of the test item is to be carried out.
0: Power off after test
1: Keep power on after test
2: Only power off
3: Power off only on error
4: Only power on
Type of the start of the analysis
Contacting setting of an external relay matrix.
Setting of the relay matrix in accordance with the choice in the program. The display is bit coded.
Type of the analysis
0 = measurement
1 =
Pass/Fail
button
StateChangeBits
Always 0, never used.
Multitest_Enable
Multitest is active, if the value does not equal 0.
Parameter_34
Parameter_35
Parameter_36
Parameter_37
Parameter_38
Parameter_39
Parameter_40
Parameter_41
Parameter_42
Multitest_Auswert ung
Multitest_Endekri terium
Method of analysing the multitest.
0 = worst measurement value.
Method of ending the multitest.
0 = number of measurements
1 = pass key
Number of multitest inspections.
Multitest_Endekri terium_Anzahl
ErrorStartConditi on
ErrorStartConditi onMask
Condition for switching forward in the event of an error.
Mask for the condition for switching further in the event of an error.
Always 0, never used.
ErrorStateChangeB its
ErrorWSBDelay
Delay of switching further in the event of an error.
ErrorWSBTimeValid
Delay time active.
Kanal
Measurement channel
0 = current
1 = analogue channel1
2 = analogue channel2
3 = analogue channel3
4 = analogue channel4
User Manual ATS400 Version 3.14.41 - 1 200
Reference
Tag
Parameter_43
Parameter_44
Parameter_45
Parameter_46
Parameter_47
Parameter_48
Parameter_49
Parameter_50
Parameter_51
Parameter_52
Parameter_53
Parameter_54
Parameter_55
Parameter_56
Parameter Explanation
SourceIsDC
5 = voltage measurement
External source provides direct current voltage
StartStateChange
Indicates whether the switching condition needs to be maintained when testing the start conditions.
0 = no waiting for switch condition
1 = Wait for switching condition
StartStateJump
Indicates whether the
Jump
button is displayed.
Graphic
Repeating
StartButton
PassButton
StartandJump
CreateLog
Timeinterval
Type of the graphics settings
0 = no graphics
1 = only display graphic
2 = display and save graphic
Indicates how often the test step is carried out.
Indicates whether the
Start
button is displayed.
Indicates whether the
Pass
button is displayed.
Indicates whether the
Start
and
Jump
buttons are displayed.
Indicates whether a log file will be created.
0 = No log file will be created
1 = A log file be created
Time interval between two samples which will be written to the log file. The value is in seconds.
This value will only be used in case the value in
CreateLog
is 1.
StartTime_Delay
Wait time for the signal
Start-Button
, in case the start condition is
monitored
.
StartPETime_Delay
Wait time for the signal
PE-Testprobe
, in case the start condition is
monitored
.
StartKUTime_Delay
Wait time for the signal
Contact
Monitoring
, in case the start condition is
monitored
.
StartSHKHVTime_De lay
Wait time for the signal
Safety Circuit
HV
, in case the start condition is
monitored
.
User Manual ATS400 Version 3.14.41 - 1 201
Reference
6.4.3.1.6 Leakage current
Parameters of the
Leakage current
test step.
Tag
Parameter_0
Parameter_1
Parameter_2
Parameter_3
Parameter_4
Parameter_5
Parameter_6
Parameter_7
Parameter_8
Parameter_9
Parameter_10
Parameter_11
Parameter_12
Parameter_13
Parameter
StartCondition
StartConditionMas k
Messmodell
Messmethode
Management
U_Source
U
I_max t t_delay f t_start
Auswertung
Polaritaet
Explanation
Start conditions of the test step. The start conditions are saved in a bit-coded manner and can only be analysed together with the
StartConditionMask
field.
Start conditions of the test step. The start conditions are saved in a bit-coded manner and can only be analysed together with the
StartCondition
field.
Measurement model used.
Measurement method used.
0: Protective conductor current
1: Housing discharge current
Indicates how the supply of the test item is to be carried out.
0: Power off after test
1: Keep power on after test
2: Only power off
3: Power off only on error
4: Only power on
Source of the test supply.
Voltage of the test item supply
Upper threshold for the discharge current.
Test time
Start delay between fulfilling the start condition and the start of the test.
Frequency of the voltage
Will not be used.
Measurement channel used for the test:
0: I AC rms
1: I DC
2: I min
3: I max
4: I rms
Polarity used of the supply of the test item.
For single-phase test item:
0: Automotive
User Manual ATS400 Version 3.14.41 - 1 202
Reference
Tag
Parameter_14
Parameter_15
Parameter_16
bis
Parameter_31
Parameter_32
Parameter_33
Parameter Explanation
1: L1-> PE
2: L2-> PE
3: Mode B
4: Automatic with first error
5: L1 -> PE with first error
6: L2 -> PE with first error
SelftestMode
Polung
With three-phase test item:
0: Clockwise rotation
1: Counterclockwise rotation
Always 0.
Contacting setting of an external relay matrix.
PolungCAN_00
PolungCan_15
bis
StateChangeBits
Setting of the relay matrix in accordance with the choice in the program. The display is bit coded.
Always 0, never used.
Multitest_Enable
Multitest is active, if the value does not equal 0.
Parameter_34
Parameter_35
Parameter_36
Parameter_37
Parameter_38
Parameter_39
Parameter_40
Parameter_41
Parameter_42
Parameter_43
Multitest_Auswert ung
Multitest_Endekri terium
Method of analysing the multitest.
0 = worst measurement value.
Method of ending the multitest.
0 = number of measurements
1 = pass key
Number of multitest inspections.
Multitest_Endekri terium_Anzahl
I_Min
ErrorStartConditi on
ErrorStartConditi onMask
Lower threshold for the discharge current.
Condition for switching forward in the event of an error.
Mask for the condition for switching further in the event of an error.
Always 0, never used.
ErrorStateChangeB its
ErrorWSBDelay
Delay of switching further in the event of an error.
ErrorWSBTimeValid
Delay time active.
StartStateChange
Indicates whether the switching condition needs to be maintained when testing the start conditions.
0 = no waiting for switch condition
1 = Wait for switching condition
User Manual ATS400 Version 3.14.41 - 1 203
Reference
Tag
Parameter_44
Parameter_45
Parameter_46
Parameter_47
Parameter_48
Parameter_49
Parameter_50
Parameter_51
Parameter_52
Parameter_53
Parameter_54
Parameter_55
Parameter
Phase
StartStateJump
Explanation
Number of phases of the test item.
Indicates whether the
Jump
button is displayed.
Repeating
StartButton
PassButton
StartandJump
CreateLog
Timeinterval
Indicates how often the test step is carried out.
Indicates whether the
Start
button is displayed.
Indicates whether the
Pass
button is displayed.
Indicates whether the
Start
and
Jump
buttons are displayed.
Indicates whether a log file will be created.
0 = No log file will be created
1 = A log file be created
Time interval between two samples which will be written to the log file. The value is in seconds.
This value will only be used in case the value in
CreateLog
is 1.
StartTime_Delay
Wait time for the signal
Start-Button
, in case the start condition is
monitored
.
StartPETime_Delay
Wait time for the signal
PE-Testprobe
, in case the start condition is
monitored
.
StartKUTime_Delay
Wait time for the signal
Contact
Monitoring
, in case the start condition is
monitored
.
StartSHKHVTime_De lay
Wait time for the signal
Safety Circuit
HV
, in case the start condition is
monitored
.
6.4.3.1.7 Sight check
Parameters of the
Sight check
test step.
Tag
Parameter_0
Parameter_1
Parameter Explanation
StartCondition
Start conditions of the test step. The start conditions are saved in a bit-coded manner and can only be analysed together with the
StartConditionMask
field.
StartConditionMas
Start conditions of the test step. The
User Manual ATS400 Version 3.14.41 - 1 204
Reference
Tag
Parameter_2
Parameter_3
Parameter_4
Parameter_5
Parameter_6
Parameter_7
Parameter_8
Parameter_9
Parameter_10
Parameter_11
Parameter_12
Parameter_13
Parameter k
Explanation
start conditions are saved in a bit-coded manner and can only be analysed together with the
StartCondition
field.
t_delay
StateChangeBits
Abfrage
Start delay between fulfilling the start condition and the start of the test.
Always 0, never used.
Mode for termination.
StartStateChange
Indicates whether the switching condition needs to be maintained when testing the start conditions.
0 = no waiting for switch condition
1 = Wait for switching condition
StartStateJump
Indicates whether the
Jump
button is displayed.
Repeating
StartButton
StartandJump
StartTime_Delay
StartSHKHVTime_De lay
Indicates how often the test step is carried out.
Indicates whether the
Start
button is displayed.
Indicates whether the
Start
and
Jump
buttons are displayed.
Wait time for the signal
Start-Button
, in case the start condition is
monitored
.
StartPETime_Delay
Wait time for the signal
PE-Testprobe
, in case the start condition is
monitored
.
StartKUTime_Delay
Wait time for the signal
Contact
Monitoring
, in case the start condition is
monitored
.
Wait time for the signal
Safety Circuit
HV
, in case the start condition is
monitored
.
6.4.3.1.8 Data input
Parameters of the
Data Input
test step.
Tag
Parameter_0
Parameter
StartCondition
Explanation
Start conditions of the test step. The start conditions are saved in a bit-coded manner and can only be analysed together with the
StartConditionMask
field.
User Manual ATS400 Version 3.14.41 - 1 205
Reference
Tag
Parameter_1
Parameter_2
Parameter_3
bis
Parameter_17
Parameter_18
Parameter_19
Parameter_20
Parameter_21
Parameter_22
Parameter_23
Parameter_24
Parameter_25
Parameter_26
Parameter_27
Parameter_28
Parameter_29
Parameter_30
Parameter_31
Parameter_32
Parameter
StartConditionMas k
Explanation
Start conditions of the test step. The start conditions are saved in a bit-coded manner and can only be analysed together with the
StartCondition
field.
Polung
PolungCAN_00
PolungCan_15
bis
StateChangeBits
Contacting setting of an external relay matrix.
Setting of the relay matrix in accordance with the choice in the program. The display is bit coded.
Always 0, never used.
Multitest_Enable
Multitest is active, if the value does not equal 0.
Multitest_Auswert ung
Multitest_Endekri terium
Method of analysing the multitest.
0 = worst measurement value.
Method of ending the multitest.
0 = number of measurements
1 = pass key
Number of multitest inspections.
Multitest_Endekri terium_Anzahl t_delay
Eingabmasken
StartStateJump
Start delay between fulfilling the start condition and the start of the test.
Bit samples containing screen fields instead of requirements.
Indicates whether the
Jump
button is displayed.
Repeating
StartButton
PassButton
StartandJump
StartTime_Delay
Indicates how often the test step is carried out.
Indicates whether the
Start
button is displayed.
Indicates whether the
Pass
button is displayed.
Indicates whether the
Start
and
Jump
buttons are displayed.
Wait time for the signal
Start-Button
, in case the start condition is
monitored
.
StartPETime_Delay
Wait time for the signal
PE-Testprobe
, in case the start condition is
monitored
.
StartTimeKU_Delay
Wait time for the signal
Contact
Monitoring
, in case the start condition
User Manual ATS400 Version 3.14.41 - 1 206
Reference
Tag
Parameter_33
Parameter
StartTimeSHKHV_De lay
Explanation
is
monitored
.
Wait time for the signal
Safety Circuit
HV
, in case the start condition is
monitored
.
6.4.3.1.9 Batch run
Parameters of the
Batch run
test step.
Tag
Parameter_0
Parameter_1
Parameter_2
Parameter_3
bis
Parameter_18
Parameter_19
Parameter_20
Parameter_21
Parameter Explanation
StartCondition
StartConditionMas k
Start conditions of the test step. The start conditions are saved in a bit-coded manner and can only be analysed together with the
StartConditionMask
field.
Start conditions of the test step. The start conditions are saved in a bit-coded manner and can only be analysed together with the
StartCondition
field.
Polung
PolungCAN_00
PolungCan_15
bis
StateChangeBits
Contacting setting of an external relay matrix.
Setting of the relay matrix in accordance with the choice in the program. The display is bit coded.
Always 0, never used.
SettingFlags
Settings that indicate that certain fields are configured at other locations. This field is bit coded.
Multitest_Enable
Multitest is active, if the value does not equal 0.
Parameter_22
Parameter_23
Parameter_24
Parameter_23
Parameter_26
Multitest_Auswert ung
Multitest_Endekri terium
Method of analysing the multitest.
0 = worst measurement value.
Method of ending the multitest.
0 = number of measurements
1 = pass key
Number of multitest inspections.
Multitest_Endekri terium_Anzahl t_delay
Eingabmasken
Start delay between fulfilling the start condition and the start of the test.
Bit samples containing screen fields instead of requirements.
User Manual ATS400 Version 3.14.41 - 1 207
Reference
Tag
Parameter_27
Parameter_28
Parameter_29
Parameter_30
Parameter_31
Parameter_32
Parameter_33
Parameter_34
Parameter_35
Parameter
StartStateJump
Explanation
Indicates whether the
Jump
button is displayed.
Repeating
StartButton
PassButton
StartandJump
StartTime_Delay
StartSHKHVTime_De lay
Indicates how often the test step is carried out.
Indicates whether the
Start
button is displayed.
Indicates whether the
Pass
button is displayed.
Indicates whether the
Start
and
Jump
buttons are displayed.
Wait time for the signal
Start-Button
, in case the start condition is
monitored
.
StartPETime_Delay
Wait time for the signal
PE-Testprobe
, in case the start condition is
monitored
.
StartKUTime_Delay
Wait time for the signal
Contact
Monitoring
, in case the start condition is
monitored
.
Wait time for the signal
Safety Circuit
HV
, in case the start condition is
monitored
.
6.4.3.1.10 User-Interface
Parameters of the
User-Interface
test step.
Tag
Parameter_0
Parameter_1
Parameter_2
Parameter_3
Parameter_4
Parameter_5
Parameter_6
Parameter
StartCondition
StartConditionMas k
In
InMask
Out
OutMask
Duration
Explanation
Start conditions of the test step. The start conditions are saved in a bit-coded manner and can only be analysed together with the
StartConditionMask
field.
Start conditions of the test step. The start conditions are saved in a bit-coded manner and can only be analysed together with the
StartCondition
field.
Entry bits
Mask for entry bits.
Output bits
Mask for output bits.
Duration of the output pulse.
User Manual ATS400 Version 3.14.41 - 1 208
Reference
Tag
Parameter_7
Parameter_8
Parameter_9
Parameter_10
Parameter_11
bis
Parameter_26
Parameter_27
Parameter_28
Parameter
Timeout
Explanation
Timeout when waiting for the status of the entry bits.
This parameter is only valid if the
TimeoutEnable
parameter is set.
TimeoutEnable t_delay
Polung
States whether timeout is used.
0: Timeout is not used
1: Timeout is used
Start delay between fulfilling the start condition and the start of the test.
Contacting setting of an external relay matrix.
PolungCAN_00
PolungCan_15
bis
StateChangeBits
Setting of the relay matrix in accordance with the choice in the program. The display is bit coded.
Always 0, never used.
Multitest_Enable
Multitest is active, if the value does not equal 0.
Parameter_29
Parameter_30
Parameter_31
Parameter_32
Parameter_33
Parameter_34
Parameter_35
Parameter_36
Parameter_37
Parameter_38
Multitest_Auswert ung
Multitest_Endekri terium
Method of analysing the multitest.
0 = worst measurement value.
Method of ending the multitest.
0 = number of measurements
1 = pass key
Number of multitest inspections.
Multitest_Endekri terium_Anzahl
ErrorStartConditi on
ErrorStartConditi onMask
Condition for switching forward in the event of an error.
Mask for the condition for switching further in the event of an error.
Always 0, never used.
ErrorStateChangeB its
ErrorWSBDelay
Delay of switching further in the event of an error.
ErrorWSBTimeValid
Delay time active.
NumInterface
Number of the user IO interface used.
0: User-IO Interface of the internal IO-
CPU
1: User-IO Interface of the external IO-
CPU
StartStateChange
Indicates whether the switching condition needs to be maintained when testing the start conditions.
0 = no waiting for switch condition
User Manual ATS400 Version 3.14.41 - 1 209
Reference
Tag
Parameter_39
Parameter_40
Parameter_41
Parameter_42
Parameter_43
Parameter_44
Parameter_45
Parameter_46
Parameter_47
Parameter
StartStateJump
Explanation
1 = Wait for switching condition
Indicates whether the
Jump
button is displayed.
Repeating
StartButton
PassButton
StartandJump
StartTime_Delay
StartSHKHVTime_De lay
Indicates how often the test step is carried out.
Indicates whether the
Start
button is displayed.
Indicates whether the
Pass
button is displayed.
Indicates whether the
Start
and
Jump
buttons are displayed.
Wait time for the signal
Start-Button
, in case the start condition is
monitored
.
StartPETme_Delay
Wait time for the signal
PE-Testprobe
, in case the start condition is
monitored
.
StartKUTime_Delay
Wait time for the signal
Contact
Monitoring
, in case the start condition is
monitored
.
Wait time for the signal
Safety Circuit
HV
, in case the start condition is
monitored
.
6.4.3.1.11 Resistance
Parameters of the
Resistance
test step.
Tag
Parameter_0
Parameter_1
Parameter_2
Parameter_3
Parameter
StartCondition
StartConditionMas k t t_start
Explanation
Start conditions of the test step. The start conditions are saved in a bit-coded manner and can only be analysed together with the
StartConditionMask
field.
Start conditions of the test step. The start conditions are saved in a bit-coded manner and can only be analysed together with the
StartCondition
field.
Test time
Delay time for the start scenario when starting the test until starting the analysis. This value is not valid for all start scenarios.
User Manual ATS400 Version 3.14.41 - 1 210
Reference
Tag
Parameter_4
Parameter_5
Parameter_6
Parameter_7
Parameter_8
bis
Parameter_23
Parameter_24
Parameter_25
Parameter_26
Parameter_27
Parameter_28
Parameter_29
Parameter_30
Parameter_31
Parameter_32
Parameter_33
Parameter_34
Parameter_35
Parameter_36
Parameter_37
Parameter Explanation t_delay
R_min
R_max
Start delay between fulfilling the start condition and the start of the test.
Lower threshold value of the resistance.
Upper threshold value of the resistance.
Polung
PolungCAN_00
PolungCan_15
bis
StateChangeBits
Contacting setting of an external relay matrix.
Setting of the relay matrix in accordance with the choice in the program. The display is bit coded.
Always 0, never used.
Multitest_Enable
Multitest is active, if the value does not equal 0.
Multitest_Auswert ung
Multitest_Endekri terium
Method of analysing the multitest.
0 = worst measurement value.
Method of ending the multitest.
0 = number of measurements
1 = pass key
Number of multitest inspections.
Multitest_Endekri terium_Anzahl
ErrorStartConditi on
ErrorStartConditi onMask
Condition for switching forward in the event of an error.
Mask for the condition for switching further in the event of an error.
Always 0, never used.
ErrorStateChangeB its
ErrorWSBDelay
Delay of switching further in the event of an error.
ErrorWSBTimeValid
Delay time active.
R_offset
Resistance of the measurement structure.
StartStateChange
Indicates whether the switching condition needs to be maintained when testing the start conditions.
0 = no waiting for switch condition
1 = Wait for switching condition
StartStateJump
Indicates whether the
Jump
button is displayed.
Repeating
Indicates how often the test step is carried out.
User Manual ATS400 Version 3.14.41 - 1 211
Reference
Tag
Parameter_38
Parameter_39
Parameter_40
Parameter_41
Parameter_42
Parameter_43
Parameter_44
Parameter_45
Parameter
StartButton
PassButton t_timeout
StartandJump
StartTime_Delay
Explanation
Indicates whether the
Start
button is displayed.
Indicates whether the
Pass
button is displayed.
Maximum time after starting until the first measurement value is recorded.
Indicates whether the
Start
and
Jump
buttons are displayed.
Wait time for the signal
Start-Button
, in case the start condition is
monitored
.
StartPETime_Delay
Wait time for the signal
PE-Testprobe
, in case the start condition is
monitored
.
StartKUTime_Delay
Wait time for the signal
Contact
Monitoring
, in case the start condition is
monitored
.
StartSHKHVTime_De lay
Wait time for the signal
Safety Circuit
HV
, in case the start condition is
monitored
.
6.4.3.1.12 Continuity test
Parameter of the
Continuity
test step.
Tag
Parameter_0
Parameter_1
Parameter_2
Parameter_3
Parameter_4
Parameter_5
Parameter_6
Parameter_7
Parameter
StartCondition
StartConditionMas k
TestVoltage
TestTime
MaxTestCurrent t_delay
Limit
Interpretation
Explanation
Start conditions of the test step. The start conditions are saved in a bit-coded manner and can only be analysed together with the
StartConditionMask
field.
Start conditions of the test step. The start conditions are saved in a bit-coded manner and can only be analysed together with the
StartCondition
field.
Maximum test voltage used for the measurement.
Time after that the measurement will be evaluated.
Maximum current during the test.
Start delay between fulfilling the start condition and the start of the test.
Limit for the evaluation.
Evaluation of the measurement:
User Manual ATS400 Version 3.14.41 - 1 212
Reference
Tag
Parameter_8
Parameter_9
Parameter_10
bis
Parameter_25
Parameter_26
Parameter_27
Parameter Explanation
TypeOfSource
Polung
PolungCAN_00
PolungCan_15
bis
StateChangeBits
1: Pass on continuity
2: Pass on discontinuity
Type of the used source:
0: Alternating current
1: direct current
Contacting setting of an external relay matrix.
Setting of the relay matrix in accordance with the choice in the program. The display is bit coded.
Always 0, never used.
Multitest_Enable
Multitest is active, if the value does not equal 0.
Parameter_28
Parameter_29
Parameter_30
Parameter_31
Parameter_32
Parameter_33
Parameter_34
Parameter_35
Parameter_36
Parameter_37
Parameter_38
Parameter_39
Multitest_Auswert ung
Multitest_Endekri terium
Method of analysing the multitest.
0 = worst measurement value.
Method of ending the multitest.
0 = number of measurements
1 = pass key
Number of multitest inspections.
Multitest_Endekri terium_Anzahl
ErrorStartConditi on
ErrorStartConditi onMask
Condition for switching forward in the event of an error.
Mask for the condition for switching further in the event of an error.
Always 0, never used.
ErrorStateChangeB its
ErrorWSBDelay
Delay of switching further in the event of an error.
ErrorWSBTimeValid
Delay time active.
StartStateChange
Indicates whether the switching condition needs to be maintained when testing the start conditions.
0 = no waiting for switch condition
1 = Wait for switching condition
StartStateJump
Indicates whether the
Jump
button is displayed.
Repeating
StartButton
Indicates how often the test step is carried out.
Indicates whether the
Start
button is displayed.
User Manual ATS400 Version 3.14.41 - 1 213
Reference
Tag
Parameter_40
Parameter_41
Parameter_42
Parameter_43
Parameter_44
Parameter_45
Parameter
PassButton
StartandJump
StartTime_Delay
Explanation
Indicates whether the
Pass
button is displayed.
Indicates whether the
Start
and
Jump
buttons are displayed.
Wait time for the signal
Start-Button
, in case the start condition is
monitored
.
StartPETime_Delay
Wait time for the signal
PE-Testprobe
, in case the start condition is
monitored
.
StartKUTime_Delay
Wait time for the signal
Contact
Monitoring
, in case the start condition is
monitored
.
StartSHKHVTime_De lay
Wait time for the signal
Safety Circuit
HV
, in case the start condition is
monitored
.
6.4.3.1.13 PT 100
Parameters of the
PT 100
test step.
Tag
Parameter_0
Parameter_1
Parameter_2
Parameter_3
Parameter_4
Parameter_5
Parameter_6
Parameter_7
Parameter_8
bis
Parameter_23
Parameter
StartCondition
StartConditionMas k t t_start t_delay
T_min
T_max
Polung
PolungCAN_00
PolungCan_15
bis
Explanation
Start conditions of the test step. The start conditions are saved in a bit-coded manner and can only be analysed together with the
StartConditionMask
field.
Start conditions of the test step. The start conditions are saved in a bit-coded manner and can only be analysed together with the
StartCondition
field.
Test time
Delay time for the start scenario when starting the test until starting the analysis. This value is not valid for all start scenarios.
Start delay between fulfilling the start condition and the start of the test.
Lower threshold for the temperature.
Upper threshold for the temperature.
Contacting setting of an external relay matrix.
Setting of the relay matrix in accordance with the choice in the program. The
User Manual ATS400 Version 3.14.41 - 1 214
Reference
Tag
Parameter_24
Parameter_25
Parameter_26
Parameter_27
Parameter_28
Parameter_29
Parameter_30
Parameter_31
Parameter_32
Parameter_33
Parameter_34
Parameter_35
Parameter_36
Parameter_37
Parameter_38
Parameter_39
Parameter_40
Parameter_41
Parameter Explanation
StateChangeBits
display is bit coded.
Always 0, never used.
Multitest_Enable
Multitest is active, if the value does not equal 0.
Multitest_Auswert ung
Multitest_Endekri terium
Method of analysing the multitest.
0 = worst measurement value.
Method of ending the multitest.
0 = number of measurements
1 = pass key
Number of multitest inspections.
Multitest_Endekri terium_Anzahl
ErrorStartConditi on
ErrorStartConditi onMask
Condition for switching forward in the event of an error.
Mask for the condition for switching further in the event of an error.
Always 0, never used.
ErrorStateChangeB its
ErrorWSBDelay
Delay of switching further in the event of an error.
ErrorWSBTimeValid
Delay time active.
R_offset
Resistance of the measurement structure.
StartStateChange
Indicates whether the switching condition needs to be maintained when testing the start conditions.
0 = no waiting for switch condition
1 = Wait for switching condition
StartStateJump
Indicates whether the
Jump
button is displayed.
R0
Repeating
StartButton
PassButton
StartandJump
Basic resistance of the measurement sensor.
Indicates how often the test step is carried out.
Indicates whether the
Start
button is displayed.
Indicates whether the
Pass
button is displayed.
Indicates whether the
Start
and
Jump
buttons are displayed.
User Manual ATS400 Version 3.14.41 - 1 215
Reference
Tag
Parameter_42
Parameter_43
Parameter_44
Parameter_45
Parameter
StartTime_Delay
Explanation
Wait time for the signal
Start-Button
, in case the start condition is
monitored
.
StartPETime_Delay
Wait time for the signal
PE-Testprobe
, in case the start condition is
monitored
.
StartKUTime_Delay
Wait time for the signal
Contact
Monitoring
, in case the start condition is
monitored
.
StartSHKHVTime_De lay
Wait time for the signal
Safety Circuit
HV
, in case the start condition is
monitored
.
6.4.3.1.14 Light control
Parameters of the
Light control
test step.
Tag
Parameter_0
Parameter_1
Parameter_2
Parameter_3
Parameter_4
Parameter_5
Parameter_6
Parameter_7
Parameter_8
Parameter_9
Parameter_10
Parameter_11
Parameter_12
Parameter_13
Parameter
StartCondition
StartConditionMas k t_delay
StateChangeBits
Leuchte_ART
Leuchte_Befehl
Leuchte_DIM
Leuchte_DALIC
Leuchte_DALIV
Leuchte_DIMT
ErrorStartConditi on
ErrorStartConditi onMask
ErrorStateChangeB its
ErrorWSBDelay
Explanation
Start conditions of the test step. The start conditions are saved in a bit-coded manner and can only be analysed together with the
StartConditionMask
field.
Start conditions of the test step. The start conditions are saved in a bit-coded manner and can only be analysed together with the
StartCondition
field.
Start delay between fulfilling the start condition and the start of the test.
Always 0, never used.
Type of the light
Command to the light
Dim value
DALIC
DALIV
DIMT
Condition for switching forward in the event of an error.
Mask for the condition for switching further in the event of an error.
Always 0, never used.
Delay of switching further in the event of
User Manual ATS400 Version 3.14.41 - 1 216
Reference
Tag
Parameter_14
Parameter_15
Parameter_16
Parameter_17
Parameter_18
Parameter_19
Parameter_20
Parameter_21
Parameter_22
Parameter_23
Parameter Explanation
an error.
ErrorWSBTimeValid
Delay time active.
StartStateChange
Indicates whether the switching condition needs to be maintained when testing the start conditions.
0 = no waiting for switch condition
1 = Wait for switching condition
StartStateJump
Indicates whether the
Jump
button is displayed.
Repeating
StartButton
StartandJump
StartTime_Delay
StartSHKHVTime_De lay
Indicates how often the test step is carried out.
Indicates whether the
Start
button is displayed.
Indicates whether the
Start
and
Jump
buttons are displayed.
Wait time for the signal
Start-Button
, in case the start condition is
monitored
.
StartPETime_Delay
Wait time for the signal
PE-Testprobe
, in case the start condition is
monitored
.
StartKUTime_Delay
Wait time for the signal
Contact
Monitoring
, in case the start condition is
monitored
.
Wait time for the signal
Safety Circuit
HV
, in case the start condition is
monitored
.
6.4.3.1.15 Dummy load
Parameters of the
Dummy load
test step.
Tag
Parameter_0
Parameter_1
Parameter_2
Parameter
StartCondition
StartConditionMas k
Management
Explanation
Start conditions of the test step. The start conditions are saved in a bit-coded manner and can only be analysed together with the
StartConditionMask
field.
Start conditions of the test step. The start conditions are saved in a bit-coded manner and can only be analysed together with the
StartCondition
field.
Indicates how the supply of the test item is to be carried out.
User Manual ATS400 Version 3.14.41 - 1 217
Reference
Parameter_3
Parameter_4
Parameter_5
Parameter_6
Parameter_7
Parameter_8
Parameter_9
Parameter_10
Parameter_11
Parameter_12
Parameter_13
Parameter_14
Parameter_15
Parameter_16
Parameter_17
Parameter_18
Parameter_19
Parameter_20
Parameter_21
Parameter_22
Parameter_23
Tag
Parameter_24
bis
Parameter_39
Parameter_40
Parameter_41
Parameter Explanation
U_Source
U f
Channels
RGas
RCoil
Filament_enable
Filament_t
Filament_delay
Filament_I
Ignition_enable
Ignition_t
Igniton_delay
Ignition_U
0: Power off after test
1: Keep power on after test
2: Only power off
3: Power off only on error
4: Only power on
Source of the test supply.
Voltage of the test item supply
Frequency of the voltage
Number of channels
Gas resistance
Coil resistance
Active flame
Active flame
Flame delay
Current of the flame
Ignition available
Ignition time
Ignition delay
Ignition voltage
Fct_Enable
Fct_t
Fct_delay
Fct_Imin
Function available
Duration of the function
Delay of the analysis
Lower threshold value of the current
Fct_Imax t_timeout
Polung
PolungCAN_00
PolungCan_15
bis
StateChangeBits
Upper threshold value of the current
Always 0
Contacting setting of an external relay matrix.
Setting of the relay matrix in accordance with the choice in the program. The display is bit coded.
Always 0, never used.
Multitest_Enable
Multitest is active, if the value does not equal 0.
Parameter_42
Parameter_43
Multitest_Auswert ung
Multitest_Endekri terium
Method of analysing the multitest.
0 = worst measurement value.
Method of ending the multitest.
0 = number of measurements
User Manual ATS400 Version 3.14.41 - 1 218
Reference
Tag
Parameter_44
Parameter_45
Parameter_46
Parameter_47
Parameter_48
Parameter_49
Parameter_50
Parameter_51
Parameter_52
Parameter_53
Parameter_54
Parameter_55
Parameter_56
Parameter_57
Parameter_58
Parameter_59
Parameter Explanation
1 = pass key
Number of multitest inspections.
Multitest_Endekri terium_Anzahl
ErrorStartConditi on
ErrorStartConditi onMask
Condition for switching forward in the event of an error.
Mask for the condition for switching further in the event of an error.
Always 0, never used.
ErrorStateChangeB its
ErrorWSBDelay
StartStateJump
Delay of switching further in the event of an error.
ErrorWSBTimeValid
Delay time active.
Filament_Imax
Max. current of the flame
Indicates whether the
Jump
button is displayed.
Repeating
StartButton
PassButton
StartandJump
StartTime_Delay
StartSHKHVTime_De lay
Indicates how often the test step is carried out.
Indicates whether the
Start
button is displayed.
Indicates whether the
Pass
button is displayed.
Indicates whether the
Start
and
Jump
buttons are displayed.
Wait time for the signal
Start-Button
, in case the start condition is
monitored
.
StartPETime_Delay
Wait time for the signal
PE-Testprobe
, in case the start condition is
monitored
.
StartKUTime_Delay
Wait time for the signal
Contact
Monitoring
, in case the start condition is
monitored
.
Wait time for the signal
Safety Circuit
HV
, in case the start condition is
monitored
.
6.4.3.1.16 Light filament current
Parameters of the
Light filament current
test step.
Tag
Parameter_0
Parameter
StartCondition
Explanation
Start conditions of the test step. The
User Manual ATS400 Version 3.14.41 - 1 219
Reference
Tag
Parameter_1
Parameter_2
Parameter_3
Parameter_4
Parameter_5
Parameter_6
Parameter_7
Parameter_8
bis
Parameter_23
Parameter_24
Parameter_25
Parameter_26
Parameter_27
Parameter_28
Parameter_29
Parameter_30
Parameter_31
Parameter_32
Parameter_33
Parameter
StartConditionMas k
Explanation
start conditions are saved in a bit-coded manner and can only be analysed together with the
StartConditionMask
field.
Start conditions of the test step. The start conditions are saved in a bit-coded manner and can only be analysed together with the
StartCondition
field.
Management
Filament_enable
Filament_t
Indicates how to proceed after the test with supplying the test item.
0: Deactivate
1: Activate
Active flame
Active flame
Filament_delay
Filament_I
Polung
PolungCAN_00
PolungCan_15
bis
StateChangeBits
Flame delay
Current of the flame
Contacting setting of an external relay matrix.
Setting of the relay matrix in accordance with the choice in the program. The display is bit coded.
Always 0, never used.
Multitest_Enable
Multitest is active, if the value does not equal 0.
Multitest_Auswert ung
Multitest_Endekri terium
Method of analysing the multitest.
0 = worst measurement value.
Method of ending the multitest.
0 = number of measurements
1 = pass key
Number of multitest inspections.
Multitest_Endekri terium_Anzahl
ErrorStartConditi on
ErrorStartConditi onMask
Condition for switching forward in the event of an error.
Mask for the condition for switching further in the event of an error.
Always 0, never used.
ErrorStateChangeB its
ErrorWSBDelay
Delay of switching further in the event of an error.
ErrorWSBTimeValid
Delay time active.
User Manual ATS400 Version 3.14.41 - 1 220
Reference
Tag
Parameter_34
Parameter_35
Parameter_36
Parameter_37
Parameter_38
Parameter_39
Parameter_40
Parameter_41
Parameter_42
Parameter_43
Parameter_44
Parameter Explanation
Filament_Imax
Max. current of the flame
StartStateChange
Indicates whether the switching condition needs to be maintained when testing the start conditions.
0 = no waiting for switch condition
1 = Wait for switching condition
StartStateJump
Indicates whether the
Jump
button is displayed.
Repeating
StartButton
PassButton
StartandJump
StartTime_Delay
StartSHKHVTime_De lay
Indicates how often the test step is carried out.
Indicates whether the
Start
button is displayed.
Indicates whether the
Pass
button is displayed.
Indicates whether the
Start
and
Jump
buttons are displayed.
Wait time for the signal
Start-Button
, in case the start condition is
monitored
.
StartPETime_Delay
Wait time for the signal
PE-Testprobe
, in case the start condition is
monitored
.
StartKUTime_Delay
Wait time for the signal
Contact
Monitoring
, in case the start condition is
monitored
.
Wait time for the signal
Safety Circuit
HV
, in case the start condition is
monitored
.
6.4.3.1.17 External program
Parameters of the
External program
test step.
Tag
Parameter_0
Parameter_1
Parameter_3
Parameter
StartCondition
StartConditionMas k
Polung
Explanation
Start conditions of the test step. The start conditions are saved in a bit-coded manner and can only be analysed together with the
StartConditionMask
field.
Start conditions of the test step. The start conditions are saved in a bit-coded manner and can only be analysed together with the
StartCondition
field.
Contacting setting of an external relay
User Manual ATS400 Version 3.14.41 - 1 221
Reference
Tag
Parameter_4
bis
Parameter_19
Parameter_20
Parameter_21
Parameter_22
Parameter_23
Parameter_24
Parameter_25
Parameter_26
Parameter_27
Parameter_28
Parameter_29
Parameter_30
Parameter_31
Parameter_32
Parameter_33
Parameter_34
Parameter_35
Parameter_36
Parameter_37
Parameter Explanation
PolungCAN_00
PolungCan_15
bis
StateChangeBits
matrix.
Setting of the relay matrix in accordance with the choice in the program. The display is bit coded.
Always 0, never used.
Multitest_Enable
Multitest is active, if the value does not equal 0.
Multitest_Auswert ung
Multitest_Endekri terium
Method of analysing the multitest.
0 = worst measurement value.
Method of ending the multitest.
0 = number of measurements
1 = pass key
Number of multitest inspections.
Multitest_Endekri terium_Anzahl
SettingsFlags t_delay
ErrorStartConditi on
ErrorStartConditi onMask
Settings
Start delay between fulfilling the start condition and the start of the test.
Condition for switching forward in the event of an error.
Mask for the condition for switching further in the event of an error.
Always 0, never used.
ErrorStateChangeB its
ErrorWSBDelay
Delay of switching further in the event of an error.
ErrorWSBTimeValid
Delay time active.
StartStateJump
Indicates whether the
Jump
button is displayed.
Repeating
StartButton
PassButton
StartandJump
StartTime_Delay
Indicates how often the test step is carried out.
Indicates whether the
Start
button is displayed.
Indicates whether the
Pass
button is displayed.
Indicates whether the
Start
and
Jump
buttons are displayed.
Wait time for the signal
Start-Button
, in case the start condition is
monitored
.
User Manual ATS400 Version 3.14.41 - 1 222
Reference
Tag
Parameter_38
Parameter_39
Parameter_40
Parameter Explanation
StartPETime_Delay
Wait time for the signal
PE-Testprobe
, in case the start condition is
monitored
.
StartKUTime_Delay
Wait time for the signal
Contact
Monitoring
, in case the start condition is
monitored
.
StartSHKHVTime_De lay
Wait time for the signal
Safety Circuit
HV
, in case the start condition is
monitored
.
6.4.4
Result
The data in this block can be found under
<ResultData>/<Result>
.
Tag
Count_Tests
Count_IO
Count_NIO
Count_ERROR
PlanCycleTime
PlanStandbyTime
Result
Type
UsedID
SerialNumber
Article
Explanation
Number of tests that were carried out since starting the test plan.
Number of IO results of the test since starting the test plan.
Number of NIO results of the test since starting the test plan.
Number of errors of the test since starting the test plan.
Duration for carrying out the test. The value is always
0.
Duration between the end of the prior test and the start of the current test.
Total result of the plan.
Passed
-> The test item has passed the test.
Failed
-> the test item has not passed the test or the test was cancelled.
Type of the test item, is only filled in if the combibox is active.
ID used to select the test plan, is only filled in when the
ID-Pattern
field is active.
Serial number of the test item, is only filled in if the
Serial-Pattern
field is active.
Article name, is only filled in if the
Article-Pattern
field is active.
User Manual ATS400 Version 3.14.41 - 1 223
Reference
6.4.5
PlanOptionen
The data in this block can be found under
<ResultData>/<PlanOptionen>
.
This block contains the subblock for the
ReportOptionen and subsequent entries.
Tag
Start_Timeout
Explanation
If the vlaue is not 0 it will be checked that all other start conditions are meet after the start condition start signal is set.
6.4.5.1 ReportOptionen
The data in this block can be found under
<ResultData>/<PlanOptionen>/
<ReportOptionen>
.
This block contains a list of the individual report options. Every report option is a
of its own.
6.4.5.1.1 ReportOption
The data in this block can be found under
<ResultData>/<PlanOptionen>/
<ReportOptionen>/<ReportOption>
.
This block contains the subblock for the
and subsequent entries.
Tag
PrintFlags
Explanation
Indicates for what overall result the report is to be created. The indication is bit-coded.
6.4.5.1.1.1 SpoolData
The data in this block can be found under
<ResultData>/<PlanOptionen>/
<ReportOptionen>/<ReportOption>/<SpoolData>
.
Tag
Template
Output
ConversionType
Explanation
File name of the template.
If the file can be reached via a relative path from the folder of the plan files, the relative path is entered, otherwise the absolute path is entered.
Indication where the report is to be sent. This indication is only filled in if the report is to be issued on a printer.
Indicates what report is to be created.
printer
-> printout on a printer using an HTML template
html
-> creation of an HTML file using an HTML template
User Manual ATS400 Version 3.14.41 - 1 224
Reference
Tag Explanation pdf
-> creation of a PDF file using an HTML template
xml
-> creation of an XML file
csv
-> creation of a CSV file using a CSV template
zebra
-> printout on a zebra printer using a ZPL template
6.4.6
Validation
The data in this block can be found under
<ResultData>/<Validation>
.
Tag
Checksum
Explanation
Not used, always 42.
6.5
6.6
Plan files
The plan files have the extension
.plan
. The place of saving and the file name result from the details in
Settings
->
File storage
->
Test plan
. This file has the format of an XML file with UTF-8 coding with BOM.
The plan files are largely identical to the result files. They differ by the encompassing
PlanData
tag instead of
ResultData
. Furthermore, the result fields in the individual test steps and the
Result
block do not apply.
Printserver configuration
This file has the name
PrintServer.conf
and resides in the working folder. This file must not be present and will not be created automatically.
In this file are settings which are used only by the printserver. These settings are for the storage of the report files, handling missing keywords and timeouts. It is possible to configure an alternative folder for each report type.
The file is in XML-format and the main tag is
Settings
.
Tag
HTML
XML
CSV
Debug
Explanation
Alternative folder for the report type
html
.
Alternative folder for the report type
.
Alternative folder for the report type
xml
.
Alternative folder for the report type
csv
.
false
: Will a keyword not be recognized no text be generated.
true
: Will a keyword not be recognized the keyword in parantheseis will be generated.
Default setting is
false
.
User Manual ATS400 Version 3.14.41 - 1 225
Reference
Tag
PdfTimeout
PrintTimeout
Explanation
Time within the PDF-document must be generated.
The value is in milliseconds.
Default is 6 seconds.
time within the printing on the printer must be completed. The value is in milliseconds.
Default is 10 seconds.
6.7
Matrix
6.7.1
RelaisMatrix.cfg
This file will be used for all relais matrix types und describes which relais will be switched for the different outputs and wires. For the types 3 and 4 also the file for the
additional relais is neccessary.
Description: Relais Matrix, 8Channel, 1xRelais_Platine, 1xLT_CPU
MatrixTyp: 1
MatrixNum: 1
Channels: 2
-----------------------------
Channel 1
A: 1, 2,
B: 1,
0:
-----------------------------
Channel 2
A: 3, 4,
B: 3,
0:
-----------------------------
Tag
Description
MatrixTyp
MatrixNum
Channels
Description
Comment which will not be proccessed.
Determines the different modules.
1
: Matrix with max. 24 relais for each board
2
: Matrix with max. 8 relais for each board
3
: Matrix with max. 16 relais for each board
4
: Matrix with max. 32 relais for each board
Number of boards in the matrix.
Number of channels in the matrix.
Between the header and the first channel resp. between the channels is a separator line. After the last channel the seperator line must be present.
Each channel consists of 4 Lines. There must be configured as much lines as set in
Channels
.
User Manual ATS400 Version 3.14.41 - 1 226
Reference
Tag
A:
B:
0:
Description
Comment which will not be proccessed.
These relais will be switched in the case wire HV1 will connected to the apropiate output.
These relais will be switched in the case wire HV2 will connected to the apropiate output.
These relais will be switched in the case none of the wires will be connected to an output.
6.7.2
ExtendedRelais.conf
This file is neccessary when a matrix of type
MatrixTyp
3 or 4 will be used.
This file is in XML-Format. For each test type as much lines must be present as boards are used according to the value
MatrixNum
in the file
the tag
unsignedInt
have a range from 0 ... 3.
1
2
Value
0
3
Description
No additional relais switched.
Additional relais K1 switched.
Additional relais K2 switched.
Both additional relais switched.
User Manual ATS400 Version 3.14.41 - 1 227
Reference
<?xml version="1.0" encoding="utf-8"?>
<
ExtendedRelais
xmlns:xsi ="
http://www.w3.org/2001/XMLSchema-instance
" xmlns:xsd ="
http://www.w3.org/2001/XMLSchema
">
<!--
Für jede Prüfart müssen so viele Zeilen vorhanden sein, wie Platinen verbaut sind = MatrixNum aus RelaisMatrix.cfg
0 = Kein Relais geschaltet, 1 = K1 geschaltet, 2 = K2 geschaltet, 3 = beide geschaltet !
-->
<
HV_AC
>
<
unsignedInt
>
0
</
unsignedInt
>
</
HV_AC
>
<
HV_DC
>
<
unsignedInt
>
0
</
unsignedInt
>
</
HV_DC
>
<
ISO
>
<
unsignedInt
>
0
</
unsignedInt
>
</
ISO
>
<
PE
>
<
unsignedInt
>
0
</
unsignedInt
>
</
PE
>
<
FCT_Current
>
<
unsignedInt
>
0
</
unsignedInt
>
</
FCT_Current
>
<
Resistance
>
<
unsignedInt
>
0
</
unsignedInt
>
</
Resistance
>
<
LeakageCurrent
>
<
unsignedInt
>
0
</
unsignedInt
>
</
LeakageCurrent
>
<
DummyLoad
>
<
unsignedInt
>
0
</
unsignedInt
>
</
DummyLoad
>
<
FCT_Extern
>
<
unsignedInt
>
0
</
unsignedInt
>
</
FCT_Extern
>
<
Notlicht
>
<
unsignedInt
>
0
</
unsignedInt
>
</
Notlicht
>
<
PT100
>
<
unsignedInt
>
0
</
unsignedInt
>
</
PT100
>
<
Matrix
>
<
unsignedInt
>
0
</
unsignedInt
>
</
Matrix
>
</
ExtendedRelais
>
User Manual ATS400 Version 3.14.41 - 1 228
Lembergstr. 23
70825 Korntal
Phone: +49 711 83 99 39-0
Fax: +49 711 83 99 39-9
Internet: www.etl-prueftechnik.de
E-Mail: [email protected]
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 6 Introduction
- 7 Administration
- 7 System setup
- 7 Windows users
- 8 Installing ETL DataView 3
- 15 Installing the PDF creator
- 15 Setting up the PDF creator
- 21 Adding to a network
- 22 Variants X6 or X8
- 22 Create network drive
- 31 Setup a network printer
- 37 Variants X4 oder X5
- 37 Network setup
- 41 Checking the network connection
- 43 Saving the settings
- 45 Checking the share
- 51 Configuration
- 53 Configuration
- 54 Setting up language
- 55 Naming the workstation
- 55 Signal tones
- 57 Safety cabinet
- 58 Startmode
- 60 Test plan selection
- 61 Examples
- 62 Article number
- 63 Article groups
- 64 Article- and serial number
- 65 Article groups and serial number
- 66 Combined entrance
- 67 Combined entrence with article groups
- 68 Variable sequence in one field
- 69 Dummy test
- 71 User administration
- 72 Add an new user
- 72 Enter password
- 72 Delete user
- 72 Assign rights
- 73 Automatic logout
- 74 File storage
- 74 Result files
- 77 Test plans
- 78 Network
- 79 Temporary files
- 80 Tool
- 80 Serial interface
- 82 Push button
- 83 Change voltage
- 83 Dummy test plan
- 87 Printserver configuration
- 90 Test plan editing
- 90 Administering test plans
- 92 Changing test plans
- 93 Test types
- 94 Common dialogs
- 94 Ramp
- 95 Start conditions
- 97 Matrix
- 98 Jump
- 99 Text
- 100 Multitest
- 102 Create log
- 103 Protective Earth test
- 104 High voltage AC
- 105 High voltage DC
- 107 Insulation test
- 108 Function test
- 110 Leakage current test
- 115 Testing modules
- 117 Supply options
- 119 Polarity for protective conducter
- 121 Polarity for touch current
- 124 Batch
- 125 Data input
- 126 Resistance
- 127 Matrix
- 129 Continuity test
- 130 Test plan settings
- 131 Text
- 132 Identification
- 133 Report options
- 137 Info
- 138 Options
- 139 Inspector
- 139 Test individual
- 140 Protective earth test
- 141 Test plan
- 142 Manual test plan selection
- 143 Automatic test plan selection
- 144 Safety cabinet
- 146 Report creation
- 146 Creating templates
- 146 Key words
- 146 Key words of the results data
- 149 Key words of the test step parameters
- 151 Key words of the Protective earth test type
- 152 Key words of the High Voltage AC test type
- 153 Key words of the High voltage DC test type
- 154 Key words of the Insulation test type
- 155 Key words of the FCT-Current test type
- 157 Key words of the Leakage current test type
- 158 Key words of the Sight check test type
- 158 Key words of the Data input test type
- 158 Key words of the Batch run test type
- 158 Key words of the User-Interface test type
- 159 Key words of the Resistance test type
- 159 Key words of the Continuity test type
- 160 Key words of the PT100 test type
- 160 Key words of the Lightcontrol test type
- 160 Key words of the Dummy load test type
- 161 Key words of the Light Filament current test type
- 162 Key words of the External programm test type
- 162 Key words of the test step measurement values
- 163 Key words of the multiple test values test step
- 163 Key words of the test step advices
- 166 Key words of the test step process control
- 167 HTML templates
- 168 Creation with Microsoft Word 2012
- 172 CSV templates
- 173 Creation with Microsoft Excel 2010
- 176 Reference
- 176 Patterns
- 177 Protective earth test
- 178 Leading of the cable
- 180 High voltage test
- 180 Evaluation of the measurement
- 180 Error messages for high voltage AC
- 180 Error messages for high voltage DC
- 181 Test for required voltage
- 181 Current error at upper limit
- 181 Results files
- 182 Header
- 183 Identification
- 183 Teststeps
- 183 TestStep
- 188 Protective Earth
- 190 High voltage AC
- 193 High voltage DC
- 196 Insulation
- 199 FCT-Current
- 202 Leakage current
- 204 Sight check
- 205 Data input
- 207 Batch run
- 208 User-Interface
- 210 Resistance
- 212 Continuity test
- 214 PT 100
- 216 Light control
- 217 Dummy load
- 219 Light filament current
- 221 External program
- 223 Result
- 224 PlanOptionen
- 224 ReportOptionen
- 224 ReportOption
- 224 SpoolData
- 225 Validation
- 225 Plan files
- 225 Printserver configuration
- 226 Matrix
- 226 RelaisMatrix.cfg
- 227 ExtendedRelais.conf