T-1S60-1S120-1S240+¹úÍâ953.119TVA-953.120TVA

Add to my manuals
17 Pages

advertisement

T-1S60-1S120-1S240+¹úÍâ953.119TVA-953.120TVA | Manualzz

PUBLIC ADDRESS SYSTEM

953.119TVA

953.120TVA

953.121TVA

POWER AMPLIFIER

Please follow the instructions in this manual to obtain the optimum results from this unit.

We also recommend that you keep this manual handy for future reference.

TABLE OF CONTENTS

1. SAFETY PRECAUTIONS

........................................................................................ 3

2. GENERAL DESCRIPTION

..................................................................................... 5

3. FEATURES

............................................................................................................... 5

4. NOMENCLATURE AND FUNCTIONS

4. 1 Front Panel ..................................................................................................................6

4. 2 Rear Panel...................................................................................................................7

5. CONNECTIONS

.........................................................................................................8

6. OPERATION GUIDANCE

6. 1 POWER SWITCH & POWER INDICATOR .......................................................................9

6. 2 PHONE JACK LINE INPUT AND XLR LINE INPUT ...........................................................9

6. 3 XLR LINE OUTPUT .................................................................................................... 10

6. 4 POWER SUPPLY INPUT .............................................................................................10

6. 5 SPEAKER OUTPUTS 4~16 & 70V& 100V.................................................................... 11

7. MACHINE OPERATION

.........................................................................................12

8. APPLICATIONS

...................................................................................................... 13

9. BLOCK DIAGRAM

...................................................................................................14

10. SPECIFICATIONS

.......................................................................... .....................15

11.DIMENSIONAL DIAGRAM

..................................................................................16

2

1. SAFETY PRECAUTIONS

Be sure to read the instructions in this section carefully before use.

Make sure to observe the instructions in this manual as the conventions of safety symbols and messages

regarded as very important precautions are included.

We also recommend you keep this instruction manual handy for future reference.

Safety Symbol and Message Conventions

Safety symbols and messages described below are used in this manual to prevent bodily injury and property damage which could result from mishandling. Before operating your product, read this manual first and understand the safety symbols and messages so you are thoroughly aware of the potential safety

Indicates a potentially hazardous situation which, if mishandled, could result in death or serious personal injury.

Indicates a potentially hazardous situation which, if mishandled, could result in moderate or minor personal injury, and/or property damage.

When Installing the Unit

Do not expose the unit to rain or an environment

where it may be splashed by water or other liquids,

as doing so may result in fire or electric shock.

Use the unit only with the voltage specified on the

unit. Using a voltage higher than that which is

specified may result in fire or electric shock.

Do not cut, kink, otherwise damage nor modify the

power supply cord. In addition, avoid using the

power cord in close proximity to heaters, and never

place heavy objects -- including the unit itself -- on

the power cord, as doing so may result in fire or

electric shock.

Be sure to replace the unit's terminal cover after

connection completion. Because high voltage is

applied to the speaker terminals, never touch these

terminals to avoid electric shock.

Be sure to ground to the safety ground (earth)

terminal to avoid electric shock. Never ground to a

gas pipe as a catastrophic disaster may result.

Avoid installing or mounting the unit in unstable

locations, such as on a rickety table or a slanted surface. Doing so may result in the unit falling

down, causing personal injury and/or property

damage.

When the Unit is in Use

Should the following irregularity be found during

use, immediately switch off the power, disconnect

the power supply plug from the AC outlet and

contact your nearest dealer. Make no further

attempt to operate the unit in this condition as this

may cause fire or electric shock.

If you detect smoke or a strange smell coming

from the unit.

If water or any metallic object gets into the unit

If the unit falls, or the unit case breaks

If the power supply cord is damaged (exposure of

the core, disconnection, etc.)

If it is malfunctioning (no tone sounds.)

To prevent a fire or electric shock, never open nor

remove the unit case as there are high voltage

components inside the unit. Refer all servicing to

your nearest dealer.

Do not place cups, bowls, or other containers of

liquid or metallic objects on top of the unit. If they

accidentally spill into the unit, this may cause a fire

or electric shock.

Do not insert nor drop metallic objects or

flammable materials in the ventilation slots of the

unit's cover, as this may result in fire or electric

shock.

3

SAFETY PRECAUTIONS

When Installing the Unit

Never plug in nor remove the power supply plug

with wet hands, as doing so may cause electric

shock.

When unplugging the power supply cord, be sure

to grasp the power supply plug; never pull on the

cord itself. Operating the unit with a damaged

power supply cord may cause a fire or electric

shock.

When moving the unit, be sure to remove its power

supply cord from the wall outlet. Moving the unit

with the power cord connected to the outlet may

cause damage to the power cord, resulting in fire or

electric shock. When removing the power cord, be

sure to hold its plug to pull.

Do not block the ventilation slots in the unit's cover.

Doing so may cause heat to build up inside the unit

and result in fire.

Avoid installing the unit in humid or dusty locations,

in locations exposed to the direct sunlight, near the

heaters, or in locations generating sooty smoke or

steam as doing otherwise may result in fire or

electric shock.

When the Unit is in Use

Do not place heavy objects on the unit as this may

cause it to fall or break which may result in

personal injury and/or property damage. In

addition, the object itself may fall off and cause

injury and/or damage.

Make sure that the volume control is set to

minimum position before power is switched on.

Loud noise produced at high volume when power is

switched on can impair hearing.

Do not operate the unit for an extended period of

time with the sound distorting. This is an indication

of a malfunction, which in turn can cause heat to

generate and result in a fire.

Contact your dealer as to the cleaning. If dust

is allowed to accumulate in the unit over a long

period of time, a fire or damage to the unit may

result.

If dust accumulates on the power supply plug or in

the wall AC outlet, a fire may result. Clean it

periodically. In addition, insert the plug in the wall

outlet securely.

Switch off the power, and unplug the power supply

plug from the AC outlet for safety purposes when

cleaning or leaving the unit unused for 10 days or

more. Doing otherwise may cause a fire or electric

shock.

An all-pole mains switch with a contact separation of at least 3 mm in each pole shall be incorporated in the electrical installation of the building.

Due to product upgrades, while some of the features and specification in the user manual does not match the actual functions, sorry for any inconvenience and thanks for your kind understanding!

4

2. GENERAL DESCRIPTION

This range of power amplifiers are designed for general commercial and industrial public address ap-

plications. Rack mount design in 2U type, rated power ranges from 60W to 240W which provides a

wide selection to meet different size sound system needs. Both balanced and unbalanced line inputs

make it selectable for installer, balanced line output feeds to another power amplifier as well as secu-

res the signal transmission is less noise and longer distance. 70V, 100V and 4-16ohm speaker outputs

are convenient for installation when selection different speaker matching. A master volume control is

included. Complete protection includes clip, short circuit, high temp and overload. Indications for

power,signal, clip, protection and temp.

3. FEATURES

1. Rack mount amplifier in 2U type

2. Rated power from 60W to 240W

3. 70V, 100V and 4~16ohm speaker outputs

4. solated transformer for human safety operation

5. Balanced XLR type line input and unbalanced 1/4 inch TRS phone jack line input

6. Balanced XLR type line output feeds to another power amplifier

7. Reliable protection of over heat, over load, clip & short circuit.

8. Indications for power, signal, clip, protection and temp

9. Excellent device of radiator cooling fanner that ensures working effectively.

10. GND/lift switch to have two options: earth line grounded or lifted

5

4. NOMENCLATURE AND FUNCTIONS

4.1 FRONT PANEL

7 6 5 4 3

1 2

1. POWER SWITCH

On top of the opening Power Press the end, power shut down

2. VOLUME

Channel volume control

3. TEMP

The protection indicator will be light on when the inside temperature is over 90C, the output

will be

cut to protect the amplifier from damage. It will resume to work after cooling down

4. PROT

The protection indicator will be light on when the constant output is 160% higher than the rated

output, the output will be cut to protection the amplifier from damage. This indicator will be

extinguished when amplifier is under normal working conditions.

5. CLIP

Clip lit when max wattage output & output signal distortion.

6. SIGNAL

Signal indicator LED When lit input signal is detected.

7. POWER

Power indicator LED

6

NOMENCLATURE AND FUNCTIONS

4.2 REAR PANEL

15

8 9 10 11 12 13 14

8. ~230V 50Hz AC POWER INPUT

9. COMMON SPEAKER OUTPUT

Connectors for 4 ohms or 70V and 100V

speaker

10. LINE INPUT (XLR)

Music signal input balance

11. LINE INPUT (6.35TRS)

Balanced or unbalanced input music signal (unbalanced input, use of non-equilibrium

6.35TRS jack)

12. LINK OUTPUT (6.35TRS)

Balanced or unbalanced output music signal (unbalanced output, use of non-equilibrium

6.35TRS jack)

13. LINE CASCADE OUTPUT (CORLEONE SOCKET)

XLR, output signal of power amplifier

14. FAN

Equipment, exhaust vents, equipment work properly, you must wrap the hole can not have any

object covered, to avoid overheating protection

15. GROUND LIFTER

Earth line ground or lift switch. Enable the switch to "GND" position when one unit is used,

disable the switch "LIFT" when several units are used to avoid noise caused by several earth

line grounded.

7

5. CONNECTIONS

SPEAKER CONNECTIONS

100V 70V COM

81

(953.119TVA)

41

20 (

( 953.120TVA

)

953.121TVA

)

100V 70V 4~16 COM

166 ( 953.119TVA

)

83

42

( 953.120TVA

( 953.121TVA

)

)

100V 70V COM

70V LINE 100V LINE 4~16 LINE

4~16 70V/

8

6. OPERATION GUIDANCE

6.1 POWER SWITCH & POWER INDICATOR

T-1S60

POWER AMPLIFIER

Picture 1.1

Electricity power on when power switch is at ON position and power indicator light in blue.

Electricity power off when power switch is at OFF position and power indicator extinguished.

Notice:

Please make sure amplifier operation is under well power supplied status. Please contact professional technician from distributor for any repairment.

6.2 PHONE JACK LINE INPUT AND XLR LINE INPUT

INPUTS

INPUTS

XLR BAL

1-GND

2-HOT+

3-COLD-

LINK

LINK

100V

INPUTS

70V 50V

OUTPUTS

4 COM

LINK

2

3

1

XLR BAL

1-GND

2-HOT+

3-COLD

INPUTS

1

3

2

OUTPUTS

AVIS:

RISK OF ELECTRIC SHOCK

DO NOT OPEN

RISQUE DE CHOC ELECTRICUS

-NE PAS QUVRIR

PUBLIC ADDRESS SYSTEM

SERIAL NO :

~220V 50Hz

T2AL 250V

1 CH Pre-Amplifier

1

3

2

70V,Speaker Output

6.3mm phono jack

180 3-pole XLR

1 foot for the ground

2 feet Signal Hot-side (positive)

3 feet signal cold side (negative)

Picture 1.2

Both phone jack and XLR inputs are balanced. Both are one of your options for line signal inputs from pre

amplifier or mixer. The line output volume level is controlled by front panel knobs

Notice: please minimum the volume knob to "MIN" position when line input is operated to avoid electricity shock to the amplifier.

9

OPERATION GUIDANCE

6.3 XLR LINE OUTPUT

INPUTS

INPUTS

XLR BAL

1-GND

2-HOT+

3-COLD-

LINK

LINK

~220V 50Hz

T2AL 250V

GND

LIFT

COM

OUTPUTS

COM COM 4-16 70V 100V

C

Power Amplifier

GND

LIFT OUTPUTS

COM COM COM 4-16 70V 100V

70V,Speaker Output

6.3mm phono jack

1

3

2

1 foot for the ground

2 feet Signal Hot-side (positive)

3 feet signal cold side (negative)

180 3-pole XLS

Picture 1.3

The XLR input is balanced. The line output could link another amplifier for more loudspeaker connection. The line output volume level is controlled by front panel knobs.

Notice: please minimum the volume knob to "MIN" position when line output is operated to avoid electricity shock to the amplifier.

6.4 POWER SUPPLY INPUT

GND

LIFT OUTPUTS

COM COM COM 4-16 70V 100V

C

Picture 1.4

Power electricity to supply power to this amplifier. Please make sure suitable AC voltage inputs by guidance of this equipments silk printing and specifications. Take off the power cord when non-use

Notice: Please input only suitable AC voltage to avoid any burn and damage to the amplifier.

10

OPERATION GUIDANCE

6.5 SPEAKER OUTPUTS 4~16 & 70V& 100V

USE ONLY WITHA 250VFUSE

GND

LIFT OUTPUTS

COM COM COM 4-16 70V 100V

C

USE ONLY WITHA 250VFUSE

GND

LIFT OUTPUTS

COM COM COM 4-16 70V 100V

C GND

LIFT

USE ONLY WITHA 250VFUSE

OUTPUTS

COM COM COM 4-16 70V 100V

C

4-16 ,SPEAK

Picture 1.5

70V,SPEAK 100V,SPEAK

High impedance and low impedance both speaker output for different application use. Only choose one of the positive end from 4~16 & 70V& 100V, then connect the negative end"COM" and one the positive end to the speaker's according ends. High impedance speaker output only for high impedance speaker connection and low impedance speaker output only for low impedance speaker connection. Speaker total power output shall be no higher than 80% percent of the amplifier rated power output.

Notice:

No mixing connected the positive and negative ends between the amplifier and loudspeaker.

Never allowed to use more than one output among 4~16 /70V/100V.

Speaker continuous power output never higher than 80% of the amplifier rated power output.

Never connect high impedance output to low impedance speaker nor connect low impedance output to

high impedance speaker.

Please cover the speaker output ends after wiring to avoid any touch. The speaker output are high voltage, never touch by human body to avoid electricity shock.

11

7. MACHINE OPERATION

M IC INPUT CHANNEL 1~3

This is a special connector which will accept 3-conductor XLR.

These inputs are suitable to receive signal from microphones level devices.

MIC JACK (XLR JACK)

Pin 1:GROUND

Pin 2:HOT(+)

Pin 3:COLD(-)

LINE JACK (TRS PHONE JACK)

Sleeve:GROUND

Tip:HOT(+)

Ring:COLD(-)

GROUND

COLD

1.GROUND

2

3

1

2.HOT

3.COLD

CH1/CH2 INPUTS

1

3

2

1.GROUND

2.HOT

3.COLD

CH1/CH2 LINKS

HOT

3

1 2

3

2

1

CH1/CH2 LINKS

CH1/CH2 INPUTS

OPERATION ATTENTION

= It indicate signal distortion when the panel's CLIP

LED is lighting red and it may caused by:

= Do not open and close the machine frequently.

Restart should be after 10 seconds

1. If there is excess signal input, the power LED

will light, in this case, please turn signal to the

minimum.

2. There is overload output if the LED is not ligh-

ting, please check the input circuit.

= When you start the machine, it will run into auto-

checking condition, its protection LED (yellow)

will shine 3 seconds. If the protection time is too

long, please check the machine or contact with

our distribution of your local place.

=

=

=

=

Power supply should match up to the machine.

The machine outfit with ground line, so please

plug on the connected-ground wire-net

As formidable shock or impact on machine s-

uch as (thunder shock, halfway signal pause,

excess rated signal input or other interference),

the machine will auto-check and restart auto-

matically.

Please switch off the switch till there is no noise

if there is a badly power abnormality or interfe-

rence.

= Contact with our local distributions if machine

is failure to work.

12

8. APPLICATIONS

REAR PANEL CONNECTIONS

GH

T

13

9. BLOCK DIAGRAM

14

10. SPECIFICATIONS

POWER AMLIFIER

MODEL

RATED POWER OUTPUT

SPEAKER OUTPUTS

INPUT SENSITIVITY

FREQUENCY RESPONSE

S/N RATIO

T.H.D

CONTROLS

INDICATORS

PROTECTION

POWER REQUIREMENTS

POWER CONSUMPTION

DIMENSION(mm)

NET WEIGHT

GROSS WEIGHT

953.119TVA

60W

953.120TVA

120W

4~16 ,70V/100V

953.121TVA

240W

775mV/0dB

50Hz~18KHz

Better than 105dB

Less than 1% at 1KHz, 1/3 rated power

Power switch, volume control

Power, clipping , Signal , protect and high

AC fuse, short-circuit , clipping and high temperature

~230V 50Hz

120W

6.9Kg

220W

484X353X88

9.3Kg

9.1Kg

10.7Kg

440W

13.2Kg

14.6Kg

15

11. DIMENSIONAL DIAGRAM

UNIT :mm

484

436

25

6

323

317

UNIT :mm

Over

100

16

Over 100

PUBLIC ADDRESS SYSTEM

PUBLIC ADDRESS SYSTEM

VersionV0.1

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement