- No category
advertisement
▼
Scroll to page 2
of 5
MLS Software EM2050 RotoBolt Electronic SwingBolt Lock USER INSTRUCTIONS Software: MLS EM2050 To open (standard mode): Enter code: i.e. 1-1-1-1-1-1 Unlock door and open. If not opened within 3 seconds, the lock secures automatically. For example: 111111 ♪♪ VdS Class 2, EN1300 Class B, UL Listed, DNV Listed, IMP Class 2 Suggested Entry Units Delta Alpha 8530 "T" Not Sold in US Bravo EuroClass To open (dual combo): Two users are required to open with dual combo. For example: 1-1-1-1-1-1 and 2-2-2-2-2-2 unlock door and open. If not opened within 3 seconds, the lock secures automatically. For example: 111111♪♪ AND 222222 ♪♪ To open with Time Delay active: Facts about EM2050 The lock operates with a numeric 6-digit or 7-digit code. Each key press is confirmed with an audio and light signal (♪ and ☼). After entry of a valid code a double signal follows (♪♪). An invalid entry is followed by a long signal (☼). After 10 seconds without entry, an already entered part of the code is cancelled. If your code is programmed with a key, insert key in key reader after the last digit of your code. Four (4) consecutive invalid codes initiates five minutes time penalty. Wait 5 minutes and try again. Two more consecutive invalid codes will restart additional 5 minutes penalty period After code entry, time delay starts, recognizable on light signal flashes ☼ at two-second interval. At the end of the delay period the open window starts, the light signal flashes and the lock beeps at 1-second interval alternately (once light ☼, once beep ♪). To open the lock, a valid code has to be entered again during the open window. If the open window expires without the lock being opened, the lock is secured again with the time delay. To Delete current action: press random key. To Extend delay time: enter valid code. The delay period will start again. For example: SYMBOL DESCRIPTION ♪♪ ♫ 111111 ♪♪ ☼ every 2 seconds (time delay) long signal ☼ listen press and hold 222222 ♪♪ 1 number on entry light (LED) stays on If lock is set to dual combo open with a different code in the open window. double signal light (LED) flashes After the time delay i-Button (e-KEY) ♪ 1 second and ☼ 1 second (open window) Open with time delay override: Enter a code, the time delay will start, then enter code provided to user 9 (time delay override code). Unlock door and open. If not opened within 3 seconds, the lock secures automatically. For example: 111111 user 9: 999999 user 1: ♪♪ time delay starts ♪♪ Change code (always with safe door open) Press and hold key “0” until double signal. The light remains on during the following actions. - Enter old code ♪♪ - Enter new code ♪♪ and repeat new code ♪♪ For example: ♪♪ ♪♪ ♪♪ ♪♪ Activate silent alarm: In case of a hold up situation, a silent alarm can be sent by entering the last code digit +1. For example: ♪♪ For example: valid Code 9-8-7-6-5-4, alarm will be sent by entering 9-8-7-6-5-5. This code works as a valid code. & Silent Alarm Signal Sent Current supply / battery change: A series of signals indicates that the battery is weak and must be replaced. Use only 9V ALKALINE - batteries!. Alpha, Bravo & "T" Series EuroClass & EuroLine Series "DT" Series "ST" & Delta Series For Entry Units ST40xx and EC10xx: The battery compartment is located inside the safe. In case the battery is drained completely, uncover the power terminals in the front of the Enty Unit and power with fresh battery. (see fig. on page 1) Keep battery pressed against the terminals until lock is completely open. MLS Software EM2050 RotoBolt Electronic SwingBolt Lock MANAGER INSTRUCTIONS Software: MLS EM2050 To open (standard mode): Enter code: i.e. 1-1-1-1-1-1 Unlock door and open. If not opened within 3 seconds, the lock secures automatically. For example: 111111 ♪♪ VdS Class 2, EN1300 Class B, UL Listed, DNV Listed, IMP Class 2 To open (dual combo): Suggested Entry Units Delta Alpha 8530 "T" Not Sold in US Bravo EuroClass Two users are required to open with dual combo. For example: 1-1-1-1-1-1 and 2-2-2-2-2-2 unlock door and open. If not opened within 3 seconds, the lock secures automatically. For example: 111111♪♪ AND 222222 ♪♪ To open with Time Delay active: Facts about EM2050 The lock operates with a numeric 6-digit or 7-digit code. Each key press is confirmed with an audio and light signal (♪ and ☼). After entry of a valid code a double signal follows (♪♪). An invalid entry is followed by a long signal (☼). After 10 seconds without entry, an already entered part of the code is cancelled. If your code is programmed with a key, insert key in key reader after the last digit of your code. After code entry, time delay starts, recognizable on light signal flashes ☼ at two-second interval. At the end of the delay period the open window starts, the light signal flashes and the lock beeps at 1-second interval alternately (once light ☼, once beep ♪). To open the lock, a valid code has to be entered again during the open window. If the open window expires without the lock being opened, the lock is secured again with the time delay. Four (4) consecutive invalid codes initiates five minutes time penalty. Wait 5 minutes and try again. Two more consecutive invalid codes will restart additional 5 minutes penalty period To Delete current action: press random key. To Extend delay time: enter valid code. The delay period will start again. Factory code for Manager is 1-2-3-4-5-6-(7) For example: SYMBOL DESCRIPTION ♪♪ ♫ long signal ☼ listen press and hold 1 number on entry light (LED) stays on double signal 111111 ♪♪ ☼ every 2 seconds (time delay) light (LED) flashes After the time delay i-Button (e-KEY) ♪ 1 second and ☼ 1 second (open window) 222222 ♪♪ If lock is set to dual combo open with a different code in the open window. Change code (always with safe door open) Press and hold key “0” until double signal. The light remains on during the following actions. - Enter old code ♪♪ - Enter new code ♪♪ and repeat new code ♪♪ Activate User Press and hold key “1” until double signal. The light remains on during the following actions. - Enter manager code ♪♪ - Enter user ID 1-9 ♪♪ (only if more than 1 user is installed) - Enter user code ♪♪ - Repeat user code ♪♪ For example: to activate user 1: “1” till ♪♪ and light stays on Manager code 1-2-3-4-5-6 ♪♪ User ID 1 ♪♪ (only if more than 1 user is installed) User code 1-1-1-1-1-1 ♪♪ User code 1-1-1-1-1-1 ♪♪ For example: 1 ♪♪ ♪♪ ♪♪ 1 ♪♪ ♪♪ ♪♪ 1 ♪♪ ♪♪ ♪♪ ♪♪ (only if more than 1 user is installed) ♪♪ ♪♪ Activate User with key Press and hold key “1” until double signal. The light remains on during the following actions. - Enter manager code ♪♪ - Enter user ID 1-9 ♪♪ - Enter user code after last digit ♪♪ insert key in key reader ♪♪ - Repeat user code ♪♪ and insert key ♪♪ ♪♪ ♪♪ For example: to activate user 1: “1” till ♪♪ and light stays on Manager code 1-2-3-4-5-6 ♪♪ User ID 1 ♪♪ User code 1-1-1-1-1-1 ♪♪ key ♪♪ User code 1-1-1-1-1-1 ♪♪ key ♪♪ Activate User in dual mode - Enter user code ♪♪ Press and hold key “1” until double signal. - Enter manager code ♪♪ - Enter user ID 1-9 ♪♪ - Enter user code ♪♪ Repeat user code ♪♪ For example: activate user 2: user 1 has been activated with 1-1-1-1-1-1 and the manager code is 1-2-3-4-5-6. 1-1-1-1-1-1 ♪♪ Press “1” till ♪♪ 1-2-3-4-5-6 ♪♪ 2 ♪♪ 2-2-2-2-2-2 ♪♪ 2-2-2-2-2-2 ♪♪ ♪♪ ♪♪ Disable/enable users (bulk) not active in dual mode! Press and hold key “2” until double signal. The light remains on during the following actions. - Enter manager code ♪♪ All users are disabled. ♪♪ ♪♪ To enable all users repeat procedure. Delete Users Press and hold key “3” until double signal. The light remains on during the following actions. - Enter manager code ♪♪ - Enter user ID ♪♪ User is deleted. For example: “3” till double signal and light stays on. Manager code 1-2-3-4-5-6 ♪♪ User ID 1 ♪♪ ♪♪ ♪♪ ♪♪ To activate user again please refer to function ‘activate user’ Please note that new user code differs from prevs code!! Programing of Time Delay and Open Window Values Press and hold key “9” until double signal. The light remains on during the following actions. - Enter manager code ♪♪ - Enter time delay and open window time - Repeat values ♪♪ For example: “9” till double signal and light stays on Manager code 1-2-3-4-5-6 ♪♪ 2612 for 26minutes time delay and 12minutes open window ♪♪. Repeat values ♪♪ ♪♪ ♪♪ ♪♪ ♪♪ Note: decreasing the time delay value can only be done in open window time. Increasing can be done at any time To remove Time Delay Removing of the time delay can only be done in open window time. Repeat Programing of Time Delay and Open Window procedure with 00 value for TimeDelay and 01 value for Open Window ♪♪ ♪♪ ♪♪ ♪♪ Audit Users Press and hold key “7” until double signal. The light remains on during the following actions. Listen to tone signals - Enter manager code ♪♪ - Enter 1,2,3,4,5,6,7,8,9 and 0 to stop double signal ♪♪ = User active with code one signal ♪ = User active with out code (or disabled) Long signal = User not active ♪♪ ♪♪ ♪♪ = User active with code ♪ = User active with out code (or disabled) ♫ = User not active Audit lock (only if 2 or more users are installed) Audit lock (only if 2 or more users are installed) Press and hold key “7” until double signal. The light remains on during the following action. - Enter manager code ♪♪ - Insert i-button in key reader till double signal ♪♪ The audit file has been downloaded to the i-button ♪♪ ♪♪ ♪♪ Current supply / battery change: A series of signals indicates that the battery is weak and must be replaced. Use only 9V ALKALINE - batteries! Alpha, Bravo & "T" Series EuroClass & EuroLine Series "DT" Series Delta & ST Series For Entry Units ST40xx and EC10xx: The battery compartment is located inside the safe. In case the battery is drained completely, uncover the power terminals in the front of the Enty Unit and power with fresh battery. (see fig. on page 1) Keep battery pressed against the terminals until lock is completely open.
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project