Allen-Bradley Kinetix 350 Single-axis EtherNet/IP, V31PR0-LM, V31PR2-LM, V32PR0-LM, V32PR2-LM, V32PR4-LM, V33PR1-LM, V33PR3-LM, V33PR5-LM, V33PR6-LM, V34PR3-LM, V34PR5-LM, V34PR6-LM Servo Drive Installation Instructions
Below you will find brief information for Kinetix 350 V33PR6-LM, Kinetix 350 V33PR5-LM, Kinetix 350 V34PR3-LM, Kinetix 350 V34PR5-LM, Kinetix 350 V34PR6-LM. These servo drives are designed to provide an Ethernet-enabled solution for applications with output power requirements in the range of 0.4 to 3.0 kW (2 to 12 A rms). Kinetix 350 servo drives are easy to install and can be easily integrated with ControlLogix or CompactLogix controller platforms.
Advertisement
Advertisement
Installation Instructions
Kinetix 350 Single-axis EtherNet/IP
Servo Drives
Catalog Numbers 2097-V31PR0-LM, 2097-V31PR2-LM, 2097-V32PR0-LM,
2097-V32PR2-LM, 2097-V32PR4-LM, 2097-V33PR1-LM, 2097-V33PR3-LM,
2097-V33PR5-LM, 2097-V33PR6-LM, 2097-V34PR3-LM, 2097-V34PR5-LM,
2097-V34PR6-LM
Topic
Page
About the Kinetix 350 Drives
Kinetix® 350 single-axis EtherNet/IP servo drives provide an Ethernet-enabled solution for applications with output power requirements in the range of 0.4…3.0 kW (2…12 A rms).
Refer to the Kinetix 350 Single-axis EtherNet/IP Servo Drives User Manual, publication
2097-UM002 , for detailed information on wiring, applying power, troubleshooting, and integration with ControlLogix® or CompactLogix™ controller platforms.
2 Kinetix 350 Single-axis EtherNet/IP Servo Drives
Important User Information
Read this document and the documents listed in the additional resources section about installation, configuration, and operation of this equipment before you install, configure, operate, or maintain this product. Users are required to familiarize themselves with installation and wiring instructions in addition to requirements of all applicable codes, laws, and standards.
Activities including installation, adjustments, putting into service, use, assembly, disassembly, and maintenance are required to be carried out by suitably trained personnel in accordance with applicable code of practice.
If this equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.
In no event will Rockwell Automation, Inc. be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment.
The examples and diagrams in this manual are included solely for illustrative purposes. Because of the many variables and requirements associated with any particular installation, Rockwell Automation, Inc. cannot assume responsibility or liability for actual use based on the examples and diagrams.
No patent liability is assumed by Rockwell Automation, Inc. with respect to use of information, circuits, equipment, or software described in this manual.
Reproduction of the contents of this manual, in whole or in part, without written permission of Rockwell Automation, Inc., is prohibited.
Throughout this manual, when necessary, we use notes to make you aware of safety considerations.
WARNING: Identifies information about practices or circumstances that can cause an explosion in a hazardous environment, which may lead to personal injury or death, property damage, or economic loss.
ATTENTION: Identifies information about practices or circumstances that can lead to personal injury or death, property damage, or economic loss. Attentions help you identify a hazard, avoid a hazard, and recognize the consequence.
IMPORTANT
Identifies information that is critical for successful application and understanding of the product.
Labels may also be on or inside the equipment to provide specific precautions.
SHOCK HAZARD: Labels may be on or inside the equipment, for example, a drive or motor, to alert people that dangerous voltage may be present.
BURN HAZARD: Labels may be on or inside the equipment, for example, a drive or motor, to alert people that surfaces may reach dangerous temperatures.
ARC FLASH HAZARD: Labels may be on or inside the equipment, for example, a motor control center, to alert people to potential Arc Flash. Arc Flash will cause severe injury or death. Wear proper Personal Protective
Equipment (PPE). Follow ALL Regulatory requirements for safe work practices and for Personal Protective
Equipment (PPE).
Rockwell Automation Publication 2097-IN008D-EN-P - July 2013
Kinetix 350 Single-axis EtherNet/IP Servo Drives 3
Catalog Number Explanation
This publication applies to the following Kinetix 350 drives.
Kinetix 350 Drives (single-phase)
Cat. No.
2097-V31PR0-LM
2097-V31PR2-LM
2097-V32PR0-LM
2097-V32PR2-LM
2097-V32PR4-LM
Input Voltage
120/240V, 1 Ø
240V, 1 Ø
Continuous Output
Current A (0-pk)
2.8
5.7
2.8
5.7
11.3
Kinetix 350 Drives (single- or three-phase)
Input Voltage Cat. No.
2097-V33PR1-LM
2097-V33PR3-LM
2097-V33PR5-LM
2097-V33PR6-LM
120V, 1 Ø
240V, 1 Ø
240V, 3 Ø
Kinetix 350 Drives (three-phase)
Input Voltage Cat. No.
2097-V34PR3-LM
2097-V34PR5-LM
2097-V34PR6-LM
480V, 3 Ø
Continuous Output
Current A (0-pk)
2.8
5.7
11.3
17.0
Continuous Output
Current A (0-pk)
2.8
5.7
8.5
Features
• 120V Doubler mode
• Safe torque-off
• Integrated AC line filter
• Safe torque-off
Features
Safe torque-off
Features
Safe torque-off
Rockwell Automation Publication 2097-IN008D-EN-P - July 2013
4 Kinetix 350 Single-axis EtherNet/IP Servo Drives
Before You Begin
Remove all packing material, wedges, and braces from within and around the components. After unpacking, check the item nameplate catalog number against the purchase order.
Parts List
The Kinetix 350 drive ships with the following:
•
General-purpose power input (IPD) header, back-up power (BP) header, shunt resistor and DC bus (BC) header, motor power (MP) header, and safe-torque-off (STO) header
•
A ground clamp that also provides strain relief for motor power cable
•
These installation instructions, publication 2097-IN008
TIP
The connector kit for motor feedback (catalog number 2090-K2CK-D15M) is not provided.
Replacement connector sets (catalog number 2097-CONN1) are also available.
Refer to the Kinetix Motion Accessories Specifications Technical Data, publication GMC-TD004 , for more information.
Install the Kinetix 350 Drive
These procedures assume you have prepared your panel, and understand how to bond your system. For installation instructions regarding equipment and accessories not included here, refer to the instructions that came with those products.
SHOCK HAZARD: To avoid hazard of electrical shock, perform all mounting and wiring of the
Kinetix 350 drive prior to applying power. Once power is applied, connector terminals can have voltage present even when not in use.
ATTENTION: Plan the installation of your system so that you can perform all cutting, drilling, tapping, and welding with the system removed from the enclosure. Because the system is open-type construction, be careful to keep any metal debris from falling into it. Metal debris or other foreign matter can become lodged in the circuitry and result in damage to components.
Rockwell Automation Publication 2097-IN008D-EN-P - July 2013
Kinetix 350 Single-axis EtherNet/IP Servo Drives 5
Mount the Kinetix 350 Drive
Follow these steps to mount the drive.
1. Observe these clearance requirements when mounting the drive to the panel.
IMPORTANT
Mount the module in an upright position as shown. Do not mount the module on its side.
A
3 mm (0.12 in.)
Side Clearance
25 mm (1.0 in.) Clearance for Airflow and Installation
25 mm (1.0 in.) Clearance for Airflow and Installation
• Additional clearance and different hole patterns are required for side mount and rear mount AC line filters. See the table and step 2 for more details.
• Additional clearance is required depending on the other accessory items installed.
• Additional clearance is required for the cable and wires connected to the top, front, and bottom of the drive.
• An additional 150 mm (6.0 in.) is required when the drive is mounted adjacent to noise sensitive equipment or clean wire ways.
Refer to page 6 for Kinetix 350 drive dimensions.
3 mm (0.12 in.)
Side Clearance
Drive
Cat. No.
2097-V31PR0-LM
2097-V31PR2-LM
2097-V32PR0-LM
2097-V32PR2-LM
2097-V32PR4-LM
Dimensions A
mm (in.)
185 (7.29)
230 (9.04)
2097-V33PR1-LM
2097-V33PR3-LM 185 (7.29)
(1)
2097-V33PR5-LM
2097-V33PR6-LM 230 (9.04)
2097-V34PR3-LM
2097-V34PR5-LM
185 (7.29)
2097-V34PR6-LM 230 (9.04)
(1)
(1) If you are using an AC line filter, add
50 mm (2 in.).
Rockwell Automation Publication 2097-IN008D-EN-P - July 2013
6 Kinetix 350 Single-axis EtherNet/IP Servo Drives
2. Mount the Kinetix 350 drive to the cabinet sub-panel with M4 (#6-32) steel machine screws torqued to 1.1 N•m (9.8 lb•in).
For catalog numbers 2097-V33PR1-LM, 2097-V33PR3-LM, 2097-V33PR5-LM,
2097-V34PR3-LM, and 2097-V34PR5-LM that use an AC line filter, refer to the AC
Line Filter Installation Instructions, publication 2097-IN003 , for the sub-panel mounting hole pattern.
Kinetix 350 Drive Mounting Dimensions
A
5.0
(0.19)
7.1
(0.28)
Dimensions are in mm (in.).
30.8
(1.21)
9.7
(0.38)
238
(9.37)
182
(7.18)
190
(7.50)
2090-K2CK-D15M
Low-profile Connector Kit for Bulletin
2090 (flying-lead) Feedback Cable
61.0
(2.40)
Cat. No.
2097-V31PR0-LM
2097-V31PR2-LM
2097-V32PR0-LM
2097-V32PR2-LM
2097-V32PR4-LM
2097-V33PR1-LM
Dimensions mm (in.)
A
185.1 (7.29)
B
68.0 (2.68)
185.1 (7.29)
229.6 (9.04)
229.6 (9.04)
229.6 (9.04)
185.1 (7.29)
68.5 (2.70)
68.0 (2.68)
68.5 (2.70)
86.8 (3.42)
68.0 (2.68)
6.6
(0.26)
11.8
(0.46)
38.1
(1.5)
B
Ø 4.57
(0.18) 3x
Additional clearance below the connector kit is necessary to provide the recommended cable-bend radius.
Cat. No.
2097-V33PR3-LM
2097-V33PR5-LM
2097-V33PR6-LM
2097-V34PR3-LM
2097-V34PR5-LM
2097-V34PR6-LM
Dimensions mm (in.)
A
185.1 (7.29)
B
68.5 (2.70)
185.1 (7.29)
229.6 (9.04)
185.1 (7.29)
185.1 (7.29)
229.6 (9.04)
94.4 (3.72)
68.0 (2.68)
68.5 (2.70)
94.4 (3.72)
68.0 (2.68)
Rockwell Automation Publication 2097-IN008D-EN-P - July 2013
Kinetix 350 Single-axis EtherNet/IP Servo Drives 7
Connector Data
Use this illustration to identify the Kinetix 350 drive features and indicators.
Kinetix 350 Drive Features and Indicators
4
5
2
3
1
6
7
8
9
12
11
10
9
13
14
11
12
15
9
10
7
8
5
6
3
4
Item Description
1
2
Data status indicator and diagnostic display
Memory module socket
Network status indicator
Module status indicator
Axis status indicator
Ethernet communication port (Port 1)
I/O (IOD) connector
Motor feedback (MF) connector
Ground Lug
Shunt resistor and DC bus (BC) connector
Back-up power (BP) connector
Display control push buttons (3)
Mains (IPD) connector
Motor power (MP) connector
Safe torque-off (STO) connector
Top View
(2097-V33PR5-LM
Kinetix 350 drive is shown)
13
Bottom View
(2097-V33PR5-LM
Kinetix 350 drive is shown)
14
15
Rockwell Automation Publication 2097-IN008D-EN-P - July 2013
8 Kinetix 350 Single-axis EtherNet/IP Servo Drives
Kinetix 350 Drive Connectors
MF
BP
BC
MP
STO
Designator
IPD
PORT1
IOD
Description
AC mains input power
Ethernet communication port
I/O
Motor feedback
Back-up power
Shunt resistor and DC bus
Motor power
Safe torque-off (STO) terminal
Mains (IPD) Connector Pinout
L1
PE
IPD Designator Description
L3
L2
AC power in (3-phase models)
AC power in
AC power in
Protective earth (ground)
L1
PE
Signal
L3
L2
Pin Orientation for 8-pin Ethernet Communication Port (port 1)
6
7
4
5
8
2
3
Port 1 Pin
1
Description
Transmit port (+) data terminal
Transmit port (-) data terminal
Receive port (+) data terminal
–
–
Receive port (-) data terminal
–
–
–
–
- RX
–
–
Signal
+ TX
- TX
+ RX
Connector
4-position plug/header
RJ45 Ethernet
SCSI 50 pin high-density connector
15-pin high-density D-shell (male)
2-pin quick-connect terminal block
7-pin quick-connect terminal block
6-pin quick-connect terminal block
6-pin quick-connect terminal block
8
1
Rockwell Automation Publication 2097-IN008D-EN-P - July 2013
I/O (IOD) Connector Pinout
29
30
31…35
36
37…38
39
40…42
43
44
45…50
5
6
IOD Pin
1…4
27
28
7…25
26
Description
Reserved
Reserved
Reserved
Reserved (not used by Kinetix 350 drives)
± Overtravel, enable and home common
Negative hardware overtravel
Positive hardware overtravel
Drive enable
Home switch
Reserved
Registration common
Reserved
Registration input
Reserved
Brake release positive
Brake release negative
Reserved
Kinetix 350 Single-axis EtherNet/IP Servo Drives 9
ENABLE
HOME_SW
–
REG_COM
–
REG
–
BRAKE+
BRAKE-
–
–
–
Signal
–
–
COM
NEG_OT
POS_OT
1
25
26
50
Rockwell Automation Publication 2097-IN008D-EN-P - July 2013
10 Kinetix 350 Single-axis EtherNet/IP Servo Drives
Motor Feedback (MF) Connector Pinout
8
9
6
7
10
MF Pin
1
2
3
4
5
11
12
13
14
15
Description
Sine differential input+
AM+ differential input+
Sine differential input-
AM- differential input-
Cosine differential input+
BM+ differential input+
Cosine differential input-
BM- differential input-
Data differential input +
Index pulse+
Common
Encoder power (+9V)
Single-ended 5V Hall effect commutation
Reserved
Data differential input -
Index pulse-
Motor thermal switch (normally closed)
(1)
Single-ended 5V Hall effect commutation
Single-ended 5V Hall effect commutation
Encoder power (+5V)
Reserved
(1) Not applicable unless motor has integrated thermal protection.
(2) Encoder power supply uses either 5V or 9V DC based on encoder and motor used.
Signal
SIN+
AM+
SIN-
AM-
COS+
BM+
COS-
BM-
DATA+
IM+
S3
–
ECOM
EPWR_9V
(2)
DATA-
IM-
TS
S1
S2
EPWR_5V
(2)
–
Control Power Back-up (BP) Pinout
BP Designator Description
+24V Positive 24V DC
-24V 24V DC power supply return
Signal
+24V DC
Return
Pin 15
Pin 11
Pin 6
Pin 10
Pin 5
Pin 1
Rockwell Automation Publication 2097-IN008D-EN-P - July 2013
Kinetix 350 Single-axis EtherNet/IP Servo Drives 11
5
6
3
4
STO Pin
1
2
Shunt Resistor and DC Bus (BC) Pinout
–
–
BC Designator Description
+
Positive DC bus and shunt resistor
+
SH Shunt resistor
Negative DC bus
Motor Power (MP) Pinout
W
V
MP Designator Description
PE Protective earth (ground)
U
Motor power out
Motor power out
Motor power out
Safe Torque-off (STO) Pinout
Description
+24V DC output from the drive
+24V DC output common
Safety status
Safety input 1 (+24V DC to enable)
Safety common
Safety input 2 (+24V DC to enable)
–
–
Signal
+
+
SH
W
V
Signal
PE
U
Signal
+24V DC control
Control COM
Safety Status
Safety Input 1
Safety COM
Safety Input 2
The Kinetix 350 drive ships with safe torque-off enabled. Connect safe torque-off inputs to a safety circuit, or install motion-allowed jumpers to obtain motion. Refer to the Kinetix 350
Single-axis EtherNet/IP Servo Drive User Manual, publication 2097-UM002 , for details.
Power Wiring Requirements
Wire must be copper with 75
°C (167 °F) minimum rating. Phasing of main AC power is arbitrary and earth-ground connection is required for safe and proper operation.
IMPORTANT
The National Electrical Code and local electrical codes take precedence over the values and methods provided.
Rockwell Automation Publication 2097-IN008D-EN-P - July 2013
12 Kinetix 350 Single-axis EtherNet/IP Servo Drives
Kinetix 350 Drive Power-wiring Requirements
Cat. No.
Description
Pin
Terminals
Signal
2097-V31PR0-LM
2097-V32PR0-LM
2097-V32PR2-LM
2097-V33PR1-LM
2097-V33PR3-LM
2097-V34PR3-LM
2097-V34PR5-LM
2097-V34PR6-LM
2097-V32PR4-LM
2097-V33PR5-LM
2097-V31PR2-LM
2097-V33PR6-LM
2097-V31PR0-LM
2097-V32PR0-LM
2097-V32PR2-LM
2097-V32PR4-LM
2097-V33PR1-LM
2097-V33PR3-LM
2097-V33PR5-LM
2097-V34PR3-LM
2097-V34PR5-LM
2097-V34PR6-LM
2097-V31PR2-LM
2097-V33PR6-LM
2097-V31PR0-LM
2097-V32PR0-LM
2097-V32PR2-LM
2097-V32PR4-LM
2097-V33PR1-LM
2097-V33PR3-LM
2097-V33PR5-LM
2097-V34PR3-LM
2097-V34PR5-LM
2097-V34PR6-LM
2097-V31PR2-LM
2097-V33PR6-LM
2097-V3
xPRx-LM
Mains input power
Motor power
Shunt resistor and DC bus
(1)
2097-V3
xPRx-LM
Control back-up power
Safe torque-off
STO-1
(2)
STO-3
STO-4
STO-5
STO-6
(1) Use only for shunt resistor connection.
(2) Use only for bypassing the STO circuit.
L3
L2
L1
PE
PE
W
V
U
+
+
SH
–
–
+24V DC
Return
+24V DC Control
Control COM
Safety Status
Safety Input 1
Safety COM
Safety Input 2
Recommended
Wire Size
mm
2
(AWG)
Strip
Length
mm (in.)
Torque
Value
N•m (lb•in)
2.5 (14)
4.0 (12)
6.0 (10)
2.5 (14)
4.0 (12)
2.5 (14)
4.0 (12)
1.5 (16)
7 (0.28) 0.5 (4.5)
7 (0.28)
7 (0.28)
0.5 (4.5)
0.56…0.79
(5.0…7.0)
7 (0.28) 0.5 (4.5)
7 (0.28) 0.5 (4.5)
7 (0.28) 0.5 (4.5)
7 (0.28) 0.5 (4.5)
6 (0.25) 0.5 (4.5)
Rockwell Automation Publication 2097-IN008D-EN-P - July 2013
Kinetix 350 Single-axis EtherNet/IP Servo Drives 13
ATTENTION: To avoid personal injury and equipment damage, verify the following:
•
Installation complies with specifications regarding wire types, conductor sizes, branch circuit protection, and disconnect devices. The National Electrical Code (NEC) and local codes outline provisions for safely installing electrical equipment.
•
Motor power connectors are used only for connection purposes. Do not use motor power connectors to turn the unit on and off.
•
Shielded power cables are grounded to prevent potentially high voltages on the shield.
Ground Your Kinetix 350 Drive to the Subpanel
If the Kinetix 350 drive is mounted on a painted subpanel, ground to a bonded cabinet ground bus with a braided ground strap or 4.0 mm
2
(12 AWG) solid-copper wire, 100 mm (3.9 in.) long.
Connecting the Braided Ground Strap
Braided
Ground Strap
Bonded Cabinet
Ground Bus
Ground Stud
Ground Grid or Power
Distribution Ground
For dimensions, see Kinetix 350 Drive Mounting Dimensions on page 6 .
Rockwell Automation Publication 2097-IN008D-EN-P - July 2013
14 Kinetix 350 Single-axis EtherNet/IP Servo Drives
Kinetix 350 Drive Motor-power Wire Shielding
A motor-power ground clamp and two #6-32 x 1 screws are supplied with the Kinetix 350 drive.
Install the supplied motor-power ground clamp within 50…75 mm (2…3 in.) of the drive by using the two #6-32 x 1 screws.
Motor Power Ground Clamp Installation
Motor Power Ground Clamp
34.0
(1.34)
Dimension are in mm (in.).
12.7
(0.50)
50…75
(2…3)
50…75
(2…3)
If panel is painted, remove paint to provide metal-to-metal contact.
Rockwell Automation Publication 2097-IN008D-EN-P - July 2013
Kinetix 350 Single-axis EtherNet/IP Servo Drives 15
Motor Overload Protection
This servo drive uses solid-state motor overload protection that operates in accordance with
UL 508C. Motor overload protection is provided by algorithms (thermal memory) that predict actual motor temperature based on operating conditions as long as control power is continuously applied. However, when control power is removed, thermal memory is not retained.
In addition to thermal memory protection, this drive provides an input for an external temperature sensor/thermistor device, embedded in the motor, to support the UL requirement for motor overload protection.
Some motors supported by this drive do not contain temperature sensors/thermistors; therefore, motor overload protection against excessive consecutive motor overloads with power cycling is not supported.
This servo drive meets the following UL 508C requirements for solid-state overload protection.
Motor Overload Protection Trip Point
Ultimately
Within 8 minutes
Within 20 seconds
Value
100% overload
200% overload
600% overload
ATTENTION: To avoid damage to your motor due to overheating caused by excessive, successive motor overload trips, follow the wiring diagram provided in the user manual for your motor and drive combination.
Refer to your servo drive user manual for the interconnect diagram that illustrates the wiring between your motor and drive.
Rockwell Automation Publication 2097-IN008D-EN-P - July 2013
Additional Resources
These documents contain additional information concerning related products from Rockwell
Automation.
Resource
Kinetix 350 Single-axis EtherNet/IP Servo Drives User Manual, publication 2097-UM002
Kinetix 300 Shunt Resistor Installation Instructions, publication
2097-IN002
Description
Provides information on how to install, configure, startup, and troubleshoot your Kinetix 350 servo drive system.
Provides information on installing and wiring Kinetix 300 shunt resistors.
Kinetix 300 AC Line Filter Installation Instructions, publication
2097-IN003
Kinetix 300 I/O Terminal Expansion Block Installation
Instructions, publication 2097-IN005
Kinetix 300 Memory Module Installation Instructions, publication 2097-IN007
Kinetix 300 Memory Module Programmer Quick Start, publication 2097-QS001
Kinetix Servo Drives Specifications Technical Data, publication publication
GMC-TD003
Kinetix Motion Accessories Specifications Technical Data,
GMC-TD004
Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1
Product Certifications website, http://www.ab.com
Provides information on installing and wiring the Kinetix 300
AC line filter.
Provides information on installing and wiring the Kinetix 300
I/O terminal expansion block.
Provides information on installing the Kinetix 300 memory module.
Provides information on using the memory module programmer to duplicate the memory module.
Provides product specifications for Kinetix Integrated Motion over EtherNet/IP, Integrated Motion over sercos interface,
EtherNet/IP networking, and component servo drive families.
Provides product specifications for Bulletin 2090 motor and interface cables, low-profile connector kits, drive power components, and other servo drive accessory items.
Provides general guidelines for installing a Rockwell
Automation® industrial system.
Provides declarations of conformity, certificates, and other certification details.
You can view or download publications at http://www.rockwellautomation.com/literature . To order paper copies of technical documentation, contact your local Allen-Bradley distributor or
Rockwell Automation sales representative.
Allen-Bradley, CompactLogix, ControlLogix, Kinetix, Rockwell Software, and Rockwell Automation are trademarks of Rockwell
Automation, Inc.
Trademarks not belonging to Rockwell Automation are property of their respective companies.
Rockwell Otomasyon Ticaret A.Ş., Kar Plaza İş Merkezi E Blok Kat:6 34752 İçerenköy, İstanbul, Tel: +90 (216) 5698400
Publication 2097-IN008D-EN-P - July 2013
Supersedes Publication 2097-IN008C-EN-P - February 2013 Copyright © 2013 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.

Public link updated
The public link to your chat has been updated.
Advertisement
Key features
- Ethernet-enabled solution
- Output power requirements: 0.4…3.0 kW (2…12 A rms)
- ControlLogix or CompactLogix controller platforms integration
- Safe torque-off feature
- Integrated AC line filter
- 120V Doubler mode
- Solid-state motor overload protection
- External temperature sensor/thermistor input