IntelliTrac X1 06-04-MAS-045-02 EN301489

ELECTRONICS TESTING CENTER, TAIWAN
EMC TESTING DEPARTMENT
Report No.: 06-04-MAS-045-02
Page: 1/15
CONFORMANCE TEST REPORT
FOR
EN 301489-1 / -7
Report No.: 06-04-MAS-045-02
Client:
Product:
Model:
Manufacturer/supplier:
Systems & Technology Corp.
GPS Vehicle Tracking Device
X1
Shutttle Inc.
Date test item received:
Date test campaign completed:
Date of issue:
2006/04/06
2006/06/01
2006/06/09
The test result only corresponds to the tested sample. It is not permitted to copy this report,
in part or in full, without the permission of the test laboratory.
Total number of pages of this test report: 15 pages
Total number of pages of this test photos: 5 pages
Test Engineer
Checked By
Approved By
Terry Huang
Jerry Huang
Tsung-Ching Lin
ELECTRONICS TESTING CENTER, TAIWAN
NO.8, LANE 29, WEN-MING RD.,
LO-SHAN TSUN, KUI-SHAN HSIANG,
TAOYUAN HSIEN 33383
TAIWAN, R.O.C.
TEL: (03) 3276170~4
INT: +886-3-3276170~4
FAX: (03) 3276188
INT: +886-3-3276188
Laboratory Introduction: Electronics Testing Center, Taiwan is recognized, filed and mutual recognition
arrangement as following:
ISO9001: TüV Product Service
ISO/IEC 17025: BSMI, CNLA, DGT, NVLAP, CCIBLAC, UL, Compliance
Filing: FCC, Industry Canada, VCCI
MRA: Australia, Hong Kong, New Zealand, Singapore, USA, Japan, Korea, China, APLAC through CNLA
FCC Registration Number: 90588, 91094, 91095
ELECTRONICS TESTING CENTER, TAIWAN
Report No.: 06-04-MAS-045-02
EMC TESTING DEPARTMENT
Page: 2/15
CONTENTS
EMC TEST REPORT .................................................................................................................... 1
CONTENTS................................................................................................................................... 2
1
2
TEST REPORT CERTIFICATION................................................................................................. 3
SUMMARY OF TEST RESULTS .................................................................................................. 4
2.1 Emission (EMI):...................................................................................................................... 4
2.2 Immunity (EMS): .................................................................................................................... 4
3 GENERAL INFORMATIONS ....................................................................................................... 5
3.1 Description of EUT: ................................................................................................................ 5
3.2 Tested Configuration:.............................................................................................................. 5
3.3 Power Supply and Cable Dedicated for EUT:......................................................................... 5
3.4 Operating Modes:.................................................................................................................... 6
3.5 Performance Criteria: .............................................................................................................. 7
3.6 Deviation Record: ................................................................................................................... 7
3.7 Modification Record: .............................................................................................................. 7
4 TEST DATA & RELATED INFORMATIONS .............................................................................. 8
4.1 Emissions: ............................................................................................................................... 8
4.1.1 Radiated Emissions Test: ................................................................................................ 8
4.1.1.1 Radiated Emissions Test Data:............................................................................. 8
4.2 Immunity:.............................................................................................................................. 12
4.2.1 Electrostatic Discharge: ................................................................................................ 12
4.2.1.1 Electrostatic Discharge Test Data: ..................................................................... 12
4.2.2 Radio Frequency Electromagnetic Field (80~1000MHz and 1400~2000MHz):.......... 14
4.2.2.1 Radio Frequency Electromagnetic Field Test Data:........................................... 14
5 EQUIPMENTS LIST FOR TESTING.......................................................................................... 15
ANNEX A: PHOTOS ................................................................................................................. A1~A5
ELECTRONICS TESTING CENTER, TAIWAN
Report No.: 06-04-MAS-045-02
EMC TESTING DEPARTMENT
Page: 3/15
1 TEST REPORT CERTIFICATION
Client
: Systems & Technology Corp.
Address
: 3F-7,No.79,Hsin Tai Wu Road,Sec.1,Hsichih,Taipei County,Taiwan,R.O.C.
Manufacturer
Shutttle Inc.
Address
No.30, Lane 76, Rei Kuang Rd., Nei-Hu Dist., Taipei, Taiwan, R.O.C.
EUT
: GPS Vehicle Tracking Device
Trade Name
IntelliTrac
Model No.
: X1
Test Standard
: EN 301489-1:V1.6.1
EN 55022:1998/A1:2000/A2:2003 (Class B)
EN 301489-7: V1.2.1
EN 61000-4-2:1995/A1:1998/A2:2001
EN 61000-4-3:2002/A1:2002
The testing described in this report has been carried out to the best of our knowledge and ability, and our
responsibility is limited to the exercise of reasonable care. This certification is not intended to believe the
sellers from their legal and/or contractual obligations.
ELECTRONICS TESTING CENTER, TAIWAN
Report No.: 06-04-MAS-045-02
EMC TESTING DEPARTMENT
Page: 4/15
2 SUMMARY OF TEST RESULTS
2.1 Emission (EMI):
EMI Phenomenon
Port
Standard
Emission
Level
(Limit)
Basic Standard
Radiated
Interference Field
Strength,
30-1000 MHz
Enclosure
ETSI EN 301 489-1/7,
Chap. 8.2
Class-B
EN 55022:1998 +
A1:2000 + A2:2003
EUT
Operating Result Applicability
Mode
OP1+
OP2+
OP4
Passed
Applicable
2.2 Immunity (EMS):
Immunity
EUT
Basic Standard Operating Result Applicability
Level
(Category)
Mode
Contact
Discharge:
Electrostatic
ETSI EN 301 489-1/7,
4kV,
EN 61000-4-2:1995
OP1+
Enclosure
Passed Applicable
Discharge (ESD)
Chap. 9.3
Air
+A1:1998+A2:2001
OP2
Discharge:
8kV
80MHz~
OP1+
RF-Electromagnetic
ETSI EN 301 489-1/7, 1000MHz, EN 61000-4-3:2002
OP2+
Passed Applicable
Enclosure
Field
Chap. 9.2
+A1:2002
1.4GHz~
OP3+
2GHz, 3V/m
OP4
EMS Phenomenon
Port
Standard
ELECTRONICS TESTING CENTER, TAIWAN
EMC TESTING DEPARTMENT
Report No.: 06-04-MAS-045-02
Page: 5/15
3 GENERAL INFORMATIONS
3.1 Description of EUT:
GPS Positioning, Vehicle Real-Time Tracking, Vehicle Fleet Management, Vehicle Security
Monitoring System.
3.2 Tested Configuration:
The EUT connected with the following peripheral devices.
Following peripheral devices and interface cables were connected during the measurement:
Product
Manufacturer
Model No.
I/O Cable
N/A
N/A
N/A
N/A
3.3 Power Supply and Cable Dedicated for EUT:
Power Supply : DC 12Vcd
Power Line
: ■ Nonshielded □ Shielded □ None ,
length:
Signal Line
: □ Nonshielded □ Shielded ■ None ,
length:
m
□ Nonshielded □ Shielded ■ None ,
length:
m
Data Line
∗ For more detailed features, please refer to User’s Manual.
1.6
m
ELECTRONICS TESTING CENTER, TAIWAN
Report No.: 06-04-MAS-045-02
EMC TESTING DEPARTMENT
Page: 6/15
3.4 Operating Modes:
OP. Mode
Description of Operating Modes
OP 2
idle Mode 900 / 1800 + GPRS
(GPRS test with R&S CMU-200 which will
automatically connect to handset with data transfer)
Call Mode 900 / 1800
OP 3
Charging
OP 4
Charging + Linking PC
OP 1
Remark:
Description of Operating Modes
Remarks
Speech Call GSM900
A speech call is established at TCH 62
idle Mode GSM900
A mode of operation of a receiver or a transceiver,
where the Equipment Under Test (EUT) is powered,
available for service and available to respond to a
request to set up a call.
Speech Call DCS1800
A speech call is established at TCH 698
idle Mode DCS1800
A mode of operation of a receiver or a transceiver,
where the Equipment Under Test (EUT) is powered,
available for service and available to respond to a
request to set up a call.
Data Call GSM900
A data call to the test system is established at TCH 62
and data is sent continuously and bidirectionally
between the EUT and the test system.
Data Call DCS1800
A data call to the test system is established at TCH
698 and data is sent continuously and bidirectionally
between the EUT and the test system.
GSM900
A communication link is established between the
mobile station and the test simulator. The transmitter
is operated at its maximum rated output power: 33
dBm (power class 4)
DCS1800
A communication link is established between the
mobile station and the test simulator. The transmitter
is operated at its maximum rated output power: 30
dBm (power class 1)
ELECTRONICS TESTING CENTER, TAIWAN
Report No.: 06-04-MAS-045-02
EMC TESTING DEPARTMENT
Page: 7/15
3.5 Performance Criteria:
General Criteria
ETSI EN 301 489-1/7 Performance criteria (these criteria are defined within the ETS):
Performance criteria for Continuous phenomena applied to Transmitters (CT)
Performance criteria for Transient phenomena applied to Transmitters (TT)
Performance criteria for Continuous phenomena applied to Receiver (CR)
Performance criteria for Transient phenomena applied to Receiver (TR)
Observation of the following functions
CT
CR
TT
TR
X
X
----
----
X
X
----
----
X
X
----
----
TCH mode maintained
X
X
X
X
idle mode maintained
X
X
X
X
no unintended transmission
X
X
X
X
no loss of user control function
X
X
X
X
no loss of stored data
X
X
X
X
RXQUAL
Call Mode
Audio breakthrough downlink:
35 dB < Ref.-Lev.
Audio breakthrough uplink:
35 dB < Ref.-Lev.
idle Mode
Call and
idle Mode
Note: “ X ” means the test applicable.
3.6 Deviation Record:
(If any deviation from additions to or exclusions from test method must be stated)
N/A
3.7 Modification Record:
No modifications were required. (That is the EUT complied with the requirements as tested.)
ELECTRONICS TESTING CENTER, TAIWAN
EMC TESTING DEPARTMENT
Report No.: 06-04-MAS-045-02
Page: 8/15
4 TEST DATA & RELATED INFORMATIONS
4.1 Emissions:
4.1.1 Radiated Emissions Test:
4.1.1.1 Radiated Emissions Test Data:
A. Operating Conditions of the EUT: OP2 Mode (GSM idle 900)
Test Date: May 19, 2006
Test Result
Passed
Test Specification
EN 55022:1998/A1:2000/A2:2003 (Class B)
Climatic Condition
Ambient Temperature: 23。C
Power Supply System
DC Power:
Emission
Frequency
(MHz)
Meter Reading
(dBuV)
HOR.
VERT.
69.515
71.270
88.015
152.660
154.214
187.100
187.117
277.090
289.960
465.110
465.670
766.270
11.3
***
18.6
10.7
***
6.0
***
4.6
***
***
9.6
***
***
13.9
***
***
8.8
***
7.1
***
3.4
11.0
***
0.6
12
Relative Humidity: 63 %RH
Vdc
CORR'd
Factor
(dB/m)
HOR.
VERT.
8.5
8.5
9.4
11.7
11.7
13.8
13.8
17.1
18.1
23.1
23.1
29.6
19.8
***
28.0
22.4
***
19.8
***
21.7
***
***
32.7
***
***
22.4
***
***
20.5
***
20.9
***
21.5
34.1
***
30.2
Results
(dBuV/m)
Limit
(dBuV/m)
Margins
(dB)
30.0
30.0
30.0
30.0
30.0
30.0
30.0
37.0
37.0
37.0
37.0
37.0
-10.2
-7.6
-2.0
-7.6
-9.5
-10.2
-9.1
-15.3
-15.5
-2.9
-4.3
-6.8
Notes: 1) Place of Measurement: Measuring site of the ETC (3F)
2) Measurement Distance: 10 m
3) Height of table on which the EUT was placed: 0.8 m
4) Height of Receiving Antenna: 1 - 4 m
5) Example Calculation: result for 69.515 MHz: 11.3 + (8.5) = 19.8 dBμV/m
6) If the data table appeared symbol of "***" means the value was too low to be measured.
If the data table appeared symbol of “#“ means the noise was low, so record the peak
7) The estimated measurement uncertainty of the result measurement is
+ 4.5dB / - 4.6dB (30MHz ≦ ƒ ≦ 300MHz)
+ 4.3dB / - 4.3dB (300MHz ≦ ƒ ≦ 1GHz)
ELECTRONICS TESTING CENTER, TAIWAN
EMC TESTING DEPARTMENT
Report No.: 06-04-MAS-045-02
Page: 9/15
B. Operating Conditions of the EUT: OP2 Mode (GSM call mode 900+GPS)
Test Date: May 19, 2006
Test Result
Passed
Test Specification
EN 55022:1998/A1:2000/A2:2003 (Class B)
Climatic Condition
Ambient Temperature: 23。C
Power Supply System
DC Power:
Emission
Frequency
(MHz)
Meter Reading
(dBuV)
HOR.
VERT.
69.520
71.310
88.015
152.610
154.370
187.120
187.210
277.120
289.270
465.250
465.370
766.410
11.2
***
18.7
10.6
***
6.1
***
4.9
***
9.7
***
***
***
13.5
***
***
9.2
***
6.7
***
3.8
***
11.1
0.9
12
Relative Humidity: 63 %RH
Vdc
CORR'd
Factor
(dB/m)
HOR.
VERT.
8.5
8.5
9.4
11.7
11.7
13.8
13.8
17.1
18.1
23.1
23.1
29.6
19.7
***
28.1
22.3
***
19.9
***
22.0
***
32.8
***
***
***
22.0
***
***
20.9
***
20.5
***
21.9
***
34.2
30.5
Results
(dBuV/m)
Limit
(dBuV/m)
Margins
(dB)
30.0
30.0
30.0
30.0
30.0
30.0
30.0
37.0
37.0
37.0
37.0
37.0
-10.3
-8.0
-1.9
-7.7
-9.1
-10.1
-9.5
-15.0
-15.1
-4.2
-2.8
-6.5
Notes: 1) Place of Measurement: Measuring site of the ETC (3F)
2) Measurement Distance: 10 m
3) Height of table on which the EUT was placed: 0.8 m
4) Height of Receiving Antenna: 1 - 4 m
5) Example Calculation: result for 69.520 MHz: 11.2 + (8.5) = 19.7 dBμV/m
6) If the data table appeared symbol of "***" means the value was too low to be measured.
If the data table appeared symbol of “#“ means the noise was low, so record the peak
7) The estimated measurement uncertainty of the result measurement is
+ 4.5dB / - 4.6dB (30MHz ≦ ƒ ≦ 300MHz)
+ 4.3dB / - 4.3dB (300MHz ≦ ƒ ≦ 1GHz)
ELECTRONICS TESTING CENTER, TAIWAN
EMC TESTING DEPARTMENT
Report No.: 06-04-MAS-045-02
Page: 10/15
C. Operating Conditions of the EUT: OP2 Mode (GSM Call mode 1800+GPS)
Test Date: May 19, 2006
Test Result
Passed
Test Specification
EN 55022:1998/A1:2000/A2:2003 (Class B)
Climatic Condition
Ambient Temperature: 23。C
Power Supply System
DC Power:
Emission
Frequency
(MHz)
Meter Reading
(dBuV)
HOR.
VERT.
69.275
71.310
88.240
152.790
154.410
187.170
187.400
277.270
288.910
465.310
465.710
766.410
11.7
***
18.1
11.2
***
***
8.0
5.9
***
***
9.4
***
***
13.6
***
***
9.8
8.1
***
***
4.4
11.4
***
1.1
12
Relative Humidity: 63 %RH
Vdc
CORR'd
Factor
(dB/m)
HOR.
VERT.
8.5
8.5
9.4
11.7
11.7
13.8
13.8
17.1
18.1
23.1
23.1
29.6
20.2
***
27.5
22.9
***
***
21.8
23.0
***
***
32.5
***
***
22.1
***
***
21.5
21.9
***
***
22.5
34.5
***
30.7
Results
(dBuV/m)
Limit
(dBuV/m)
Margins
(dB)
30.0
30.0
30.0
30.0
30.0
30.0
30.0
37.0
37.0
37.0
37.0
37.0
-9.8
-7.9
-2.5
-7.1
-8.5
-8.1
-8.2
-14.0
-14.5
-2.5
-4.5
-6.3
Notes: 1) Place of Measurement: Measuring site of the ETC (3F)
2) Measurement Distance: 10 m
3) Height of table on which the EUT was placed: 0.8 m
4) Height of Receiving Antenna: 1 - 4 m
5) Example Calculation: result for 69.275 MHz: 11.7 + (8.5) = 20.2 dBμV/m
6) If the data table appeared symbol of "***" means the value was too low to be measured.
If the data table appeared symbol of “#“ means the noise was low, so record the peak
7) The estimated measurement uncertainty of the result measurement is
+ 4.5dB / - 4.6dB (30MHz ≦ ƒ ≦ 300MHz)
+ 4.3dB / - 4.3dB (300MHz ≦ ƒ ≦ 1GHz)
ELECTRONICS TESTING CENTER, TAIWAN
EMC TESTING DEPARTMENT
Report No.: 06-04-MAS-045-02
Page: 11/15
D. Operating Conditions of the EUT: OP2 Mode (GSM idle 1800)
Test Date: May 19, 2006
Test Result
Passed
Test Specification
EN 55022:1998/A1:2000/A2:2003 (Class B)
Climatic Condition
Ambient Temperature: 23。C
Power Supply System
DC Power:
Emission
Frequency
(MHz)
Meter Reading
(dBuV)
HOR.
VERT.
69.540
71.230
88.210
152.670
154.370
187.210
187.410
277.190
289.860
465.215
465.240
766.310
11.2
***
18.4
11.3
***
***
7.6
5.3
***
***
9.8
***
***
13.5
***
***
9.4
7.7
***
***
3.9
11.2
***
0.9
12
Relative Humidity: 63 %RH
Vdc
CORR'd
Factor
(dB/m)
HOR.
VERT.
8.5
8.5
9.4
11.7
11.7
13.8
13.8
17.1
18.1
23.1
23.1
29.6
19.7
***
27.8
23.0
***
***
21.4
22.4
***
***
32.9
***
***
22.0
***
***
21.1
21.5
***
***
22.0
34.3
***
30.5
Results
(dBuV/m)
Limit
(dBuV/m)
Margins
(dB)
30.0
30.0
30.0
30.0
30.0
30.0
30.0
37.0
37.0
37.0
37.0
37.0
-10.3
-8.0
-2.2
-7.0
-8.9
-8.5
-8.6
-14.6
-15.0
-2.7
-4.1
-6.5
Notes: 1) Place of Measurement: Measuring site of the ETC (3F)
2) Measurement Distance: 10 m
3) Height of table on which the EUT was placed: 0.8 m
4) Height of Receiving Antenna: 1 - 4 m
5) Example Calculation: result for 69.540 MHz: 11.2 + (8.5) = 19.7 dBμV/m
6) If the data table appeared symbol of "***" means the value was too low to be measured.
If the data table appeared symbol of “#“ means the noise was low, so record the peak
7) The estimated measurement uncertainty of the result measurement is
+ 4.5dB / - 4.6dB (30MHz ≦ ƒ ≦ 300MHz)
+ 4.3dB / - 4.3dB (300MHz ≦ ƒ ≦ 1GHz)
ELECTRONICS TESTING CENTER, TAIWAN
EMC TESTING DEPARTMENT
Report No.: 06-04-MAS-045-02
Page: 12/15
4.2 Immunity:
4.2.1 Electrostatic Discharge:
4.2.1.1 Electrostatic Discharge Test Data:
A. Operating Conditions of the EUT: Operation Mode (OP1+OP2)
Test Date: Jun. 01, 2006
Test Result
Passed
Test Specification
EN 61000-4-2:1995/A1:1998/A2:2001
Climatic Condition
Ambient Temperature: 23。C
Power Supply System
DC Power:
Energy-Storage Capacitor : 150
Vdc.
pF Discharge Resistor : 330
Ω
Discharge Times : 10
Contact Discharge
\ Discharge Mode
\ESD Voltage
12
Relative Humidity: 55%RH
2
kV
4
kV
times/each condition
Air Discharge
kV
kV
2
kV
4
kV
8
kV
kV
+
−
+
−
+
−
+
−
+
−
+
−
+
−
+
−
VCP
A
A
A
A
--
--
--
--
--
--
--
--
--
--
--
--
HCP
A
A
A
A
--
--
--
--
--
--
--
--
--
--
--
--
1~7
A
A
A
A
--
--
--
--
--
--
--
--
--
--
--
--
8~15
--
--
--
--
--
--
--
--
A
A
A
A
A
A
--
--
16~21
--
--
--
--
--
--
--
--
A
A
A
A
B
B
--
--
\Points\Result\Polarity
Note: “ A ” means the EUT function was correct during the test.
“ B ” means the EUT function was not correct during the test, which was recovered by itself after test.
“ -- ” means the test could not be carried out.
ELECTRONICS TESTING CENTER, TAIWAN
Report No.: 06-04-MAS-045-02
EMC TESTING DEPARTMENT
Page: 13/15
TEST POINTS
VCP
VCP
12
4
2
11
9
8
10
3
13
1
17
6
18
7
15
20
21
16
14
19
5
VCP
VCP
HCP
ELECTRONICS TESTING CENTER, TAIWAN
EMC TESTING DEPARTMENT
Report No.: 06-04-MAS-045-02
Page: 14/15
4.2.2 Radio Frequency Electromagnetic Field (80~1000MHz and 1400~2000MHz):
4.2.2.1 Radio Frequency Electromagnetic Field Test Data:
A. Operating Conditions of the EUT: Operation Mode (OP1+OP2)
Test Date: May 12, 2006
Test Result
Passed
Test Specification
EN 61000-4-3:2002/A1:2002
Climatic Condition
Ambient Temperature: 18。C
Power Supply System
DC Power:
Frequency Range
12
:80 MHz ~ 1000 MHz
1400 MHz ~ 2000 MHz
Sweep Rate :≤ 1.5×10-3 decades/s
Relative Humidity: 65%RH
Vdc
Field Strength :3 V/m
Modulation (AM 1kHz 80%)
Step Size :≤ 1 % of preceding frequency value
Dwell Time :3 s
Frequency Range (MHz)
Polarization of Device
Test Result
80~1000
Vertical
A
80~1000
Horizontal
A
1400~2000
Vertical
A
1400~2000
Horizontal
A
Note: “ A ” means the EUT function was correct during the test.
Sound pressures (uplink and downlink direction) and RXQUAL were observed with the audio
monitoring system.
ELECTRONICS TESTING CENTER, TAIWAN
EMC TESTING DEPARTMENT
Report No.: 06-04-MAS-045-02
Page: 15/15
5 EQUIPMENTS LIST FOR TESTING
Item
Name
Manufacturer
Model
Calibration
Date
Recommended
Recal. Date
1
EMI Test Receiver
HP
8546A
Aug. 06, 2005
Dec. 12, 2006
2
Ant.-LogBicone
EMCO
3142
Mar. 08, 2005
Mar. 29, 2007
3
Electrostatic Discharge
Simulator
Noiseken
ESS-2000-G365
Nov. 28, 2005
Nov. 27, 2006
4
Microphone
B&K
4134
Nov. 18, 2005
Nov. 17, 2006
5
Sound Level Calibrator
B&K
4231
Dec. 10, 2005
Dec. 09, 2006
6
Conditioning Amplifier
B&K
type 2690
Nov. 22, 2005
Nov. 21, 2006
7
Audio Analyzer
R&S
UPA
May 25, 2005
May 24, 2007
8
Universal Digital Radio
R&S
Communication Tester
CMU 200
Oct. 12, 2005
Oct. 11, 2006
9
Signal Generator
Agilent
8648D
Jun. 09, 2005
Jun. 08, 2007
10
EPM Series Power
Meter
Agilent
E4419B
Nov. 18, 2005
Nov. 17, 2006
11
RF Power Amplifier
AR
50S1G4AM1
May 31, 2005
May 30, 2007
12
Wide Band RF
Amplifier
KALMUS
7100LC
Nov. 18, 2005
Nov. 17, 2006
ELECTRONICS TESTING CENTER, TAIWAN
Report No.: 06-05-MAS-111
EMC TESTING DEPARTMENT
ANNEX A: PHOTOS
1. Radiated Emissions Test Setup Photos
Photos Page: A1/A5
ELECTRONICS TESTING CENTER, TAIWAN
Report No.: 06-05-MAS-111
EMC TESTING DEPARTMENT
2. Electrostatic Discharge Immunity Test Setup Photo
3. RF Radiated Fields Immunity Test Setup Photo
Photos Page: A2/A5
ELECTRONICS TESTING CENTER, TAIWAN
Report No.: 06-05-MAS-111
4. Outside view 1 of EUT
5. Outside view 2 of EUT
EMC TESTING DEPARTMENT
Photos Page: A3/A5
ELECTRONICS TESTING CENTER, TAIWAN
Report No.: 06-05-MAS-111
6. Inside view of EUT
7. Front view of PCB
EMC TESTING DEPARTMENT
Photos Page: A4/A5
ELECTRONICS TESTING CENTER, TAIWAN
Report No.: 06-05-MAS-111
8. Rear view of PCB
EMC TESTING DEPARTMENT
Photos Page: A5/A5
Download PDF