YO IE YI-55 11, 12, 13, 31, 51, 52, 53, 71, 72, 73, 74 Programmable DC Power Supply User manual
Below you will find brief information for Programmable DC Power Supply YI-55 YI-5511, Programmable DC Power Supply YI-55 YI-5512, Programmable DC Power Supply YI-55 YI-5513, Programmable DC Power Supply YI-55 YI-5551, Programmable DC Power Supply YI-55 YI-5552 and Programmable DC Power Supply YI-55 YI-5553. These high-performance power supplies offer programmable DC output with a communication interface, fast rise time speed (the YI-5511 reaches less than 10mS, the YI-5551 less than 20mS), and versatile solutions for design and test requirements. The YI-55 series can be programmed through the keyboard on the panel and also function as voltmeter and milliohmmeter for added convenience. They provide cost-effective solutions compared to similar programmable power supplies.
Advertisement
Advertisement
YO IE ENTERPRISE CORP., LTD USER MANUAL YI-55 Series Programmable DC Power Supply YI-5511/YI-5512/YI-5513/YI-5531/ YI-5551/YI-5552/YI-5553/ YI-5571/YI-5572/YI-5573/YI-5574 宥億企業股份有限公司 YO IE ENTERPRISE CORP., LTD Tel: +886-2-7746-3368 Fax:+886-2-2557-7497 E-mail: [email protected] Web: www.yoie.com.tw 地址:103 台北市大同區寧夏路 61 號 2 樓 Add: 2F., No.61, Ningxia Rd., Datong Dist., Taipei City 103, Taiwan (R.O.C.) 1 YI-55 Series Programmable DC Power Supply Content Chapter 1 Introduction ......................................................................................................................... 3 Chapter 2 Technical Specifications ..................................................................................................... 4 2.1 Main Technical Specification ........................................................................................................ 4 2.2 Supplemental Characteristics....................................................................................................... 7 2.3 YI-55 Power Supply Dimension.................................................................................................... 7 Chapter 3 Quick Start ........................................................................................................................ 10 3.1 Front Panel and Rear Panel ....................................................................................................... 10 3.2 Preliminary Checkout ................................................................................................................. 11 3.3 If the Power Supply Does Not Turn On ...................................................................................... 11 3.4 How to Adjust the Carrying Handle ............................................................................................ 12 3.5 How to Rackmount the Instrument ............................................................................................. 12 Chapter 4 Panel Operation................................................................................................................ 14 4.1 Key Layout .................................................................................................................................. 14 4.2 Front-panel Operation Overview ................................................................................................ 15 4.3 Constant Voltage Operation ....................................................................................................... 15 4.4 Constant Current Operation ....................................................................................................... 16 4.5 Saving and Recalling Operation................................................................................................. 16 4.6 Menu Operation .......................................................................................................................... 16 4.6.1 Menu Description ................................................................................................................. 16 4.6.2 Menu Function ..................................................................................................................... 19 4.7 Output On-Off Operation ............................................................................................................ 23 4.8 Remote Measurement Function ................................................................................................. 23 4.9 Milliohmmeter Function .............................................................................................................. 24 4.10 Voltmeter Function ................................................................................................................... 25 Chapter 5 Remote Operation Mode .................................................................................................. 26 5.1 YI-131/YI-132/YI-133 Communication Cable ............................................................................. 26 5.2 Communication between Power Supply and PC ....................................................................... 28 Chapter 6 SCPI Communication Protocal ......................................................................................... 30 6.1 SCPI Communication Command Introduction ........................................................................... 30 6.2 Command Introduction of YI-55 Power Supply .......................................................................... 31 6.2.1 Basic command (IEEE-488.2 Common Command Set) ..................................................... 31 6.2.2 System Command ............................................................................................................... 31 6.2.3 Measurement Command ..................................................................................................... 32 6.2.4 Setting Command ................................................................................................................ 33 6.2.5 List Operation Related Command ....................................................................................... 36 2 YO IE ENTERPRISE CORP., LTD Chapter 1 Introduction YI-55 series power supply is high performance single-output programmable DC power supply with communication interface, possessing the character of fast rise time speed (The rise speed of YI-5511 power supply can be less than 10mS and the YI-5551 can be less than 20mS). The combination of bench-top and system features in YI-55 power supplies provides versatile solutions for your design and test requirements. The YI-55 series can not only be programmed through the keyboard on the panel, but also be functioned as voltmeter and milliohmmeter, which will bring great convenience to the users. As a regeneration product of ordinary programmable power supplies, YI-55 series power supply is more cost-effective. YI-5531 power supply, a new generation of programmable linear power supply, are designed with high speed dynamic programming output(Voltage 0-30V, 1ms rising time), high current accuracy (0.001mA resolution) and low internal resistance, which can satisfy all the test requirements. Meanwhile, the voltage level switch works without relay, which will cause the fast switch between high voltage and low voltage. Moreover, YI-5531 power supply provides the best solutions for cellphone research, micro-electronics lab,research institue and special users requiring power supply with low current buthigh accuracy. Features Low ripple and noise High resolution and accuracy (0.1mV/0.01mA, YI-5531 reaches up to 0.001mA) Built-in a high-accuracy 5 1/2 voltmeter and milliohmmeter Supporting high-accuracy and dynamic programming output High-luminance VFD screen and two lines& four ways display Smart fan will be automatically initiated according to the temperature Supporting remote voltage compensation and multidata storage Supporting external trigger input and output Power-on-self-test, software calibration and standard rack mountable Supporting RS232/RS485/USB interface 3 YI-55 Series Programmable DC Power Supply Chapter 2 Technical Specifications 2.1 Main Technical Specification YI-551X series power supply technical specification table Model YI-5511 YI-5512 YI-5513 YI-5531 Voltage 0-30V 0-75V 0-150V 0-30V Current 0-5A 0-2A 0-1A 0-1A Voltage <0.01%+0.5mV <0.01%+0.5mV <0.01%+0.5mV <0.01%+0.5mV Current <0.01%+0.1mA <0.01%+0.1mA <0.01%+0.1mA <0.01%+0.1mA Voltage 0.5mV 1mV 2mV 0.5mV Current 0.1mA 0.05mA 0.01mA 0.01mA Voltage 0.1mV 0.1mV 1mV 0.1mV Current 0.01mA 0.01mA 0.01mA 0.001mA Voltage 0.01%+2mV 0.01%+5mV 0.01%+10mV 0.01%+2mV Current 0.05%+1mA 0.05%+0.5mA 0.05%+0.1mA 0.05%+0.1mA Voltage 0.02%+5mV 0.02%+15mV 0.02%+35mV 0.02%+5mV Current 0.1%+5mA 0.05%+2mA 0.05%+1mA 0.02%+1mA Voltage 3mvp-p 5mvp-p 10mvp-p 10mvp-p Current 2mA rms 1mA rms 0.5mA rms 0.5mA rms Output Rating Load Regulation Setting Value Resolution Readback Value Resolution Setting Value Accuracy Readback Value Accuracy Ripple Voltmeter Accuracy Milliohmmeter Accuracy Working Condition Power Required 0-12V Accuracy: 0.02%+2mV 0-58V Accuracy: 0.02%+5mV 10W. 0-1000mΩ Accuracy: 0.2%+3mΩ 1000-10000 mΩ Accuracy: 0.2%+6mΩ Weight 6.5Kg Dimension 214mmW x 101.5mmH x 365mmD 0-40°C; 0-90%RH AC 120V/220V±10%; 50/60HZ 4 YO IE ENTERPRISE CORP., LTD YI-555X series power supply technical specification table Model YI-5551 YI-5552 YI-5553 Voltage 0-6V 0-30V 0-75V Current 0-60A 0-20A 0-8A Voltage <0.01%+1mV <0.01%+1mV <0.01%+1mV Current <0.01%+0.1mA <0.01%+0.1mA <0.01%+0.1mA Output Rating Load Regulation Setting Value Resolution Voltage 0.1mV 0.5mV 1mV Current 1mA 0.5mA 0.2mA Readback Value Voltage 0.1mV 0.1mV 0.1mV Resolution Current 0.1mA 0.1mA 0.1mA Setting Value Accuracy Voltage 0.01%+1mV 0.01%+5mV 0.01%+10mV Current 0.05%+6mA 0.05%+2mA 0.05%+1mA Voltage 0.02%+2mV 0.02%+5mV 0.02%+15mV Current 0.05%+45mA 0.05%+20mA 0.05%+8mA Voltage 3mvp-p 5mvp-p 7mvp-p Current 15mA rms 7mA rms 4mA rms Readback Value Accuracy Milliohmmeter Accuracy 0-12V Accuracy: 0.02%+2mV 0-58V Accuracy: 0.02%+5mV 10W. 0-1000mΩ Accuracy: 0.2%+3mΩ 1000-10000 mΩ Accuracy: 0.2%+6mΩ Working Condition 0-40°C; 0-90%RH Power Required AC 120V/220V+10%; 50/60HZ Weight 28Kg Dimension 428mmW×88mmH×453.5mmD Voltmeter Accuracy 5 YI-55 Series Programmable DC Power Supply YI-557X series power supply technical specification table Model YI-5571 YI-5572 YI-5573 YI-5574 Voltage 0-15V 0-30V 0-75V 0-100V Current 0-60A 0-35A 0-15A 0-11A Voltage <0.01%+1mV <0.01%+1mV <0.01%+1mV <0.01%+1mV Output Rating Load Regulation Current <0.01%+0.1mA <0.01%+0.1mA <0.01%+0.1mA <0.01%+0.1mA Setting Value Voltage 0.1mV 0.5mV 2mV 2mV Resolution Current 1mA 0.5mA 0.2mA 0.2mA Readback Value Voltage 0.1mV 0.1mV 0.1mV 1mV Resolution Current 0.1mA 0.1mA 0.1mA 0.1mA Setting Value Accuracy Voltage 0.01%+1mV 0.01%+5mV 0.01%+10mV 0.01%+15mV Current 0.05%+6mA 0.05%+2mA 0.05%+1mA 0.05%+1mA Voltage 0.03%+3mV 0.03%+5mV 0.03%+15mV 0.03%+25mV Current 0.05%+45mA 0.05%+25mA 0.05%+12mA 0.05%+10mA Voltage 4mvp-p 5mvp-p 6mvp-p 8mvp-p Current 15mA rms 8mA rms 3mA rms 2.5mA rms Readback Value Accuracy Voltmeter Accuracy Milliohmmeter Accuracy Working Condition 0-12V Accuracy: 0.02%+2mV 0-58V Accuracy: 0.02%+5mV 10W. 0-1000mΩ Accuracy: 0.2%+3mΩ 1000-10000 mΩ Accuracy: 0.2%+6mΩ Power Required AC 125V/220V+10%; 50/60HZ Weight 45Kg Dimension 482mmW×184.5mmH×531mmD 0-40°C; 0-90%RH 6 YO IE ENTERPRISE CORP., LTD 2.2 Supplemental Characteristics State storage memory: 50 user-configurable stored states Recommended calibration interval: 1 year AC input ratings (selectable via switch on the rear panel) Option Opt.01: 220VAC ± 10%, 47 to 63 Hz Option Opt.02: 110VAC ± 10%, 47 to 63 Hz Cooling: forced cooling Operating temperature: 0 to 40 °C Storage temperature: -20 to 70 °C Environmental conditions: designed for indoor use installation categoryⅡ, pollution degree 2 environment. Designed to operate at maximum relative humidity of 90% 2.3 YI-55 Power Supply Dimension The dimension of YI-5581X/YI-5531 series is 214mm W x 101.5mm H x 365mm D. Diagram 2.1 YI-551X/YI-5531 Power Supply Dimension 7 YI-55 Series Programmable DC Power Supply The dimension of YI-555X Series is 428mm W×88mm H×453.5mm D. Diagram 2.2 YI-555X Power Supply Dimension 8 YO IE ENTERPRISE CORP., LTD The dimension of YI-557X series is 482mm W×184.5mm H×531mm D. Diagram 2.3 YI-557X Power Supply Dimension 9 YI-55 Series Programmable DC Power Supply Chapter 3 Quick Start This chapter mainly focuses on the brief introduction of the surface appearance and basic functions of YI-55 series power supply so that both experienced and inexperienced users can be acquainted with the new products quickly. Meanwhile, the chapter also clarifies some preliminary checkout that should be made prior to operation to make sure the normal running of the products. 3.1 Front Panel and Rear Panel The front panel layout of YI-551X series power supply is as follows: Diagram 3.1 the Front Panel of YI-5581X Series Power Supply The upper half is black VFD display screen and knob The bottom half, left side to right side, is numberic keys 0-9, esc key, function keys, up-down keys, enter key, input terminall and output terminal The rear panel layout of YI-5581X is as follows: Diagram 3.2 the Rear Panel of YI-551X Series Power Supply ① cooling window ② multifunction connector (remote sensing connector, trigger connector and GND connector) ③ 9-pin serial port interface connector ④ line voltage selection switch (110 VAC or 220 VAC) 10 YO IE ENTERPRISE CORP., LTD ⑤ AC input connector 3.2 Preliminary Checkout The following steps help you verify that the power supply is ready for use. 1. Check the list of supplied items Verify that you have received the following items with your power supply. If anything is missing, contact your nearest sales office. One power cord for your location The user’s manual One CD (only when you have bought communication accessories) One communication cable (only when you have bought communication accessories) One test line (only YI-5511 ,YI-5512 ,YI-5513, YI-5531 have the test line) 2.Connect the power cord and turn on the power supply When you turn on the power supply, the VFD display screen will light up briefly and the power supply performs its power-on self-test. Please check if there is any stroke loss on VFD display. Warning:Your power supply is equipped with a 3-wire grounding type power cord. The power supply is grounded only when the power-line cord is plugged into an appropriate receptacle. Do not operate your power supply without adequate cabinet ground connection. 3.3 If the Power Supply Does Not Turn On Use the following steps to help solve problems you might encounter when turning on the instrument. 1. Verify that there is AC power to the power supply. First, verify that the power cord is firmly plugged into the power receptacle on the rear panel of the power supply. You should also make sure that the power source you plugged the power supply into is energized. Then, verify that the power supply is turned on. 2. Verify the power-line voltage setting. The line voltage is set to the proper value for your country (110VAC or 220VAC) when the power supply is shipped from the factory. Change the voltage setting if it’s not correct. 3. Verify that the correct power-line fuse is installed. If the fuse was damaged, please see the table below to replace the fuse for your power supply. Model Fuse Description(110VAC) Fuse Description(220VAC) YI-5511 T5A 250V T3.15A 250V YI-5512 T5A 250V T3.15A 250V 11 YI-55 Series Programmable DC Power Supply YI-5513 T5A 250V T3.15A 250V YI-5531 T5A 250V T3.15A 250V YI-5551 T10A 250V T6.3A 250V YI-5552 T10A 250V T6.3A 250V YI-5553 T10A 250V T6.3A 250V YI-5571 T15A 250V T10A 250V YI-5572 T15A 250V T10A 250V YI-5573 T15A 250V T10A 250V YI-5574 T15A 250V T10A 250V 4. How to replace the power-line fuse Open the plastic cover which locates at below the power input socket in the rear panel of the power supply by screwdriver, then you will see the fuse. Please replace the damaged fuse with the matched fuse. 3.4 How to Adjust the Carrying Handle To adjust the position, grasp the handle by the sides and pull outward. Then, rotate the handle to the desired position. There are following three positions for you to choose: Diagram 3.3 YI-55 Series Power Supply Viewing Positions 3.5 How to Rackmount the Instrument The power supply can be mounted in a standard 19-inch rack cabinet and be easily applied to your testing system. If you want to rackmount the YI-55 Series, please buy YI-151 rack kit. Note:Remove the carrying handle and the rubber coating on the front panel before rackmounting the instrument. 12 YO IE ENTERPRISE CORP., LTD Diagram 3.4 to Rackmount a Single Instrument Diagram 3.5 to Rackmount two Instruments Side by Side 13 YI-55 Series Programmable DC Power Supply Chapter 4 Panel Operation This chapter mainly introduces the front-panel operation in detail from the following parts: Key Layout The Front Panel Operation Overview Voltage Set Operation Current Set Operation Saving and Recalling Operation Menu Operation Output ON/OFF Operation Remote Measurement Function Milliohmmeter Function Voltmeter Function 4.1 Key Layout Function Keys Multifunction Keys Diagram 4.1 Operation Panel Multifunction Keys Description 0~9 Numberic keys Menu Menu operation key List List output operation Trigger Trigger key V/mΩ Voltmeter and milliohmmeter switch button 0.1W Choose 0.1W power output operation when the instrument is used as an milliohmmeter 1W Choose 1W power output when the instrument is used as an milliohmmeter 10W Choose 10W power output when the instrument is used as an milliohmmeter Local Local operation Esc Esc key (can be exited from any working condition) 14 YO IE ENTERPRISE CORP., LTD Function Keys Description Set the voltage value V-set Set the current value I-set Save Save the current settings to a specified storage location Recall Recall the saved settings from a specified storage location Menu Menu operation: set the parameter of the power supply On/Off Control the output on/off state Used together with the multifunction keys to perform diversity functions and Shift applications(for example: shift+Menu can perform menu function) ▲ Up-key: choose menu item in menu operation or to increase the output voltage ▼ Down-key: choose menu item in menu operation or to reduce the output voltage Enter the selected value or setting Enter 4.2 Front-panel Operation Overview The following section describes an overview of the front-panel keys before operating your power supply. The power supply is shipped from the factory configured in the front-panel operation mode. At power-on, the power supply is automatically set to operate in the front-panel operation mode. When in this mode, the front panel keys can be used. When the power supply is in remote operation mode, you cannot use the front-panel. A change between front-panel and remote operation modes will not result in any change in the output parameters. You can change the front-panel and remote operation modes by PC. The output of the power supply can be enabled or disabled from the front panel by pressing the key On/Off . The VFD display shows the current operating status of the power supply with annunciators. When it is powered on, the VFD will display two lines of data. The first line shows the actual voltage value, actual current value and power supply’s status while the second line shows the voltage value that can be measured by voltmeter and output setting value of the power supply. 4.3 Constant Voltage Operation The constant voltage range is from 0V to the maximum voltage value of each model. It is very easy for you to set the constant voltage output. You have 2 solutions to set the constant voltage value. Solution 1: Press the ▲ and ▼ keys to change the value when the YI-55 series power supply is powered on. Solution 2: Step1. Power on the YI-55 series instrument Step2. Press V-Set key Step3. Press the numeric keys 0 to 9 to enter the voltage value you wanted 15 YI-55 Series Programmable DC Power Supply Step4. Press Enter to confirm the value When you close Knob Lock function in Config menu, the following two operations also can be used: 1) Use upper revolving encoder directly to adjust voltage; 2) Press key then use upper revolving encoder to adjust voltage V-Set 4.4 Constant Current Operation The constant current output range is from 0 A to the maximum current value of each type. It is very easy for you to set the constant current output. Step1. Power on the YI-55 series instrument Step2. Press I-Set key Step3. Use the numeric keys 0 to 9 to enter the voltage value you wanted Step4. Press Enter key to confirm the value If you close knob lock function in config menu, please use following operation: Press I-Set key then use upper revolving encoder to adjust voltage 4.5 Saving and Recalling Operation You can store up to 50 different output states in storage register locations(0~49) so that you can recall the saved settings quickly. This kind of store operation can be performed by the keys Save and Recall located in the front panel. When the fast recalling is activated, you can press the numberic keys 0 to 9 to invoke the corresponding data. Each output state includes: 1. Constant voltage value, 2.Constant current value, 3.Maximun voltage setting value, 4. Step voltage value. After you setting an output state (CV value, CC value and Maximum voltage), press the Save key and the numeric keys 0 to 9 to store the output value in a specified memory location. Press the Recall key and the numeric keys 0 to 9 to recall the output value from a specified memory location. 4.6 Menu Operation 4.6.1 Menu Description Press the key MENU to access to the menu function and at the moment the VFD display screen shows the menu items. You can select the menu items by pressing the ▲ and ▼ keys or by rotating the knob, and then press the key the key Esc ENTER to enter in the menu item you wanted. Or you can press to get back to the higher level menu. The first level menu includes: Config: set the function of power supply System set: set the system parameter List Set: set list operation Auto test: set auto test operation 16 YO IE ENTERPRISE CORP., LTD Output Timer: set the duation of output SN: the serial number of the power supply Exit: exit the first-level menu When accessing to Config item, the following menu items will be displayed on the VFD display screen by pressing the keys ▲ and ▼. Init: set all settings to factory default set Out Memory: set the power supply’s output state when it is powered on On Off(Default) Setting the same state as last time you turned off the power supply. Setting the output to OFF state when the power supply is powered on. TRI KeepOut: set TRI as preseved output port On Off(Default) When TRI is in low voltage level, the output state of power supply is ON. When TRI is in high voltage level, the output state of power supply is OFF. When the TRI KeepOut is enabled, the ON/OFF on the front panel is invalid. The TRI Keepout is only valid to ordinary operation mode. It is invaid to list opeartion and auto test mode. Disabled Fast Recall: set key shortcut function On Off(Default) In the main interface (not enter any menu of the power supply), press the key 0~9 to recall the parameters set by Save function Disabled Key Sound: set the key sound On(Default) Off The buzzer will sound when any key was pressed. The buzzer will not sound when any key was pressed Knob Lock: set the knob lock state On Off(Default) The knob is locked and rotating the knob will not cause any change of the setting value. The knob is unlocked and rotating the knob will cause change of the setting value. Remote Sense: set the remote sense mode On Off(Default) Activating the remote sense mode ( Rear-panel measurement mode) Activating the front-panel measurement mode Curr Unit: set the unit of current 17 YI-55 Series Programmable DC Power Supply mA A(Default) Set the unit of current is mA Set the unit of current is A Match Power: set the matching power 50 HZ(Default) Match 50HZ 60 HZ Match 60HZ Baudrate Set: set the baud rate 4800 9600(Default) 19200 38400 Setting the baudrate as 4800bps Setting the baudrate as 9600bps Setting the baudrate as 19200bps Setting the baudrate as 38400bps Comm. Parity: set the communication parity None(Default) Even Odd Setting no parity bit Setting comm. parity as even parity bit Setting comm. parity as odd parity bit Key Lock Set: set the key lock and password function Password= When set the password as 0 or pressing the key Enter directly, the Key Lock Set is disable. When the Key Lock Set is enable, the Key Lock Set get locked if no keyboard operation within 60 seconds, the Key Lock Set gets enable only if you input the correct password. Exit: exit from the current menu When accessing to System Set item,the following menu items will be displayed on the VFD display screen by pressing the keys ▲ and ▼. Max Volt: set the maximum voltage of the power supply Max Volt= Setting the maximum voltage Step Volt: set the step voltage Step= After the step voltage set, the voltage value increases or discreases equal to each step voltage by pressing the key ▲ or ▼ once. Exit: exit from the current menu When accessing to the List Set item, the following menu items will be displayed on the VFD display screen by pressing the keys ▲ and ▼. Load List File: read list file 18 YO IE ENTERPRISE CORP., LTD Edit List File: edit list file Continuous Continuous mode, start from the first step to the last step. Loop mode, repeatedly execute the steps in accordance with the order of the list. Step mode, execute single step for one trigger. Loop Mode Step Mode Edit File Format: format file in list operation 1X200 Steps Set list file as 1X200 step 2X100 Steps Set list file as 2X100 step 4X50 Steps Set list file as 4X50 step 8X25 Steps Set list file as 8X25 step Exit: exit from the current menu When accessing to the Auto Test item, the following menu items will be displayed on the VFD display screen by pressing the keys ▲ and ▼. Load Atest File: read auto test file Edit Atest File: edit auto test file Exit: exit the auto test menu When accessing to the Output Timer item, you can see the item Close Delay, which means to set the output timing. Close Delay:set the duration of the output The unit of the Close Delay is second, the accuracy is 0.001 second;The output switch to OFF state when the duration is over. The function is disable when the duration is set 0 second. The disable state is the defualt state. The function is invaild when the TRI KeepOut is used in ordinary working modes. When accessing to the SN item, the 18 digits serial number shows on the VFD display. For example: SN= 080010960121229001 Note: When accessing to the Menu item, you can press Esc or Exit to exit the menu operation. No matter which function the instrument is performing, you can exit the function operation status by pressing the key .. Esc 4.6.2 Menu Function The output state setup after the intrument powered on (>Out Memory) This instruction is used to set the output state when the power supply is powered on. If you select the item On, the power supply will set the output to OFF state when the power supply is powered on. If 19 YI-55 Series Programmable DC Power Supply you select the item Off, the output will remain the same state as last time you turned off the power supply. Setting the Key Sound (Key Sound) This instruction can switch on/off the buzzing sound when you press any key, If you select the item On, the buzzer will sound when any key was pressed. If you select Off, the buzzer will not sound when the keys were pressed. Default setting is the item On; the buzzer will sound when you press any key. Setting the Baudrate (>Baudrate Set) This instruction can change the communication baud rate of the power supply; the baud rate range is 4800bps, 9600bps, 19200bps, 38400bps. Before the communication, you must make sure that there is same baud rate between the power supply and the computer. Default baud rate is 9600bps. Setting Password for Function Keys (>Key Lock Set) This instruction can set a password (1 through 8 digits) to lock the function keys operation. After setting the password, the key V-Set,Save,Recall,Menu will be locked if no operation on keyboard in 60 seconds. Only if you put the correct password, the above keys are able to unlock. If you don’t want to lock the function keys, please don’t press any number key or just put 0 when you enter the Key Lock Set item, just press Enter key to unlock it. List Operation (>List Set) You can set every single-step value and duration time by new list operation so as to get different output list. The parameters of the list operation include the name of the list file which are input, input single step numbers (200steps at most), single step duration time (1mS at least) and the setting value of every single step. When list operation is under Continuous mode, the power supply will begin the list operation until the list operation is finished or until receiving the next trigger signal. Before editing the list, if you want to change the file storage format, please operate as the following steps: 1) Press the keys Shift and Menu to access to the menu function. 2) When VFD display screen shows the item Menu Config, press the key ▼ twice to select the item List Set, press the key Enter to confirm. 3) When VFD display screen shows the item Load ListFile, Press the key ▼ twice, select the item Edit File Format, press the key Enter to confirm. 4) When VFD display screen shows 8*25 Steps, Press the key ▼, select a list mode you want from 1*200 Steps,2*100 Steps, 4*50 Steps, press the key 1*200 steps means to set list file as 1X200 step 2*100 steps means to set list file as 2X100 step 20 Enter to confirm. YO IE ENTERPRISE CORP., LTD 4X50 steps means to set list file as 4X50 step 8X25 steps means to set list file as 8X25 step 5) Press ▼ to select the item Edit List File, press the key Enter to confirm. 6) When VFD display screen show the item Edit List File 1, press the key ▲ and ▼ to select sequential number you want to edit, press the key Enter to confirm. 7) When VFD display screen show the item List x Steps= xxx, press numberic keys to set the total list steps. Press the key Enter to confirm. 8) When VFD display screen show the item List File x Loop Mode, press the key ▲ and ▼ to select operation mode: Continuous means to start from the first step to the last step, stop the exsiting executing until next trigger Loop Mode means to looping execute list file Step Mode means excute one stpe after the trigger 9) When VFD display screen show the item Step 1 Time= xxxxx mS, press numberic keys to set time for step 1, press the key Enter to confirm. 10) When VFD display screen show the item Step 1 Volt= xxxxx V, press numberic keys to set voltage for step 1, press the key Enter to confirm. 11) When VFD display screen show the item Step 1 Curr= xxxxx A, press numberic keys to set current for step 1, press the key Enter to confirm. 12) Repeat step 9, 10, 11 to complete all steps in list file 13) Repeat step 5 to 15 to edit other list files if needed 14) Press ▼ to select Load ListFile, press the key Enter to confirm. 15) Press the key ▲ and ▼ to select sequential number you want to load, press the key Enter to confirm. The instrument is in the List mode. The VFD display screen shows OFF in the right when output is on. VFD display screen shows List1 in the right when output is off. Press the key On/Off to execute. Press key Shift+2 or Esc to exit. Press key Shift+2 direct to excute the last list file. 16) Under loop mode, the instrument looping executes automatically. Please find the following table at Continuous Mode and Step Mode: Diagram 4.2 Continious Trigger (2 Times Cyclical) When the list operation is under the Step Mode, the power supply will not be changed to next step until receiving a trigger signal. Please refer to the following diagram: 21 YI-55 Series Programmable DC Power Supply Diagram 4.3 Step Mode Automatic Test (>Auto Test) You can check if the equipment is qualified by editing the automatic test files, such as the value set, comparison parameters, delay time, inputting the step number (50 steps at most). 4 data of automatic test files can be edited. How to edit automatic test files: 1) When the VFD display shows the item Menu Config,press the key ▼ tripple to select the item Auto Test,followed by pressing the key Enter to confirm. 2) When the VFD display shows the item Load Atest File,press the key ▼ and choose the item Enter Edit Atest File, followed by pressing the key to confirm. 3) When the VFD display shows the item Edit Atest File 1,press the keys sequential number that need to be edited, followed by pressing the key 4) When the VFD display shows Atestx Steps= of list file, followed by pressing the key and ▼ and select the Enter to confirm. xxx,press the numeric keys to set the total steps Enter to confirm. 5) When the VFD display shows Step 1 Test Curr, press the keys and ▼ to select one of the following testing types: Volt means to test the output voltage. Curr means to test the current. DVM means to test voltmeter input. 6) When the VFD display shows Step 1 Time= xxxxx S, press the numeric keys to set the test duration, followed by pressing the key Enter to confirm. Please note that the duration range is 0.2S-25.5S. If delay time is set as 25.5S, the power supply will be automatically in the pause mode and go on excuting only when another trigger is input. 7) When the VFD display shows Step 1 Volt= xxxxx V, press the numeric keys to set the voltage, followed by pressing the key Enter to confirm. 8) When the VFD display shows Step 1 Curr= xxxxx A, press the numeric keys to set the current, followed by pressing the key Enter to confirm. 9) When the VFD display shows Step 1 Max= xxxxx X, press the numeric keys to set the maximum value for the qualified test, followed by pressing the key 22 Enter to confirm. YO IE ENTERPRISE CORP., LTD 10) When the VFD display shows Step 1 Min= xxxxx X,press the numeric keys to set the minimum value for the qualified test, followed by pressing the key Enter to confirm. 11) Repeat from step 5 to step 10 to set all the other steps. 12) Repeat from step 2 to step 11 to edit other automatic test files according to your need. 13) Press the key▼ to select the item Load Atest File, followed by pressing the key Enter to confirm. 14) Then the intrument enter into the automatic test mode, showing AUT1 at the right upper corner of the VFD display and OFF at the right lower corner of the VFD display. That means to wait for a trigger. 15) There are three trigger modes for automatic test Press the key On/Off to trigger. Press the key Shift+3 to trigger. Become the high voltage level to the low voltage level by Trig_in at the rear panel and last more than 5mS. 16) When the power supply is having the automatic test, the word Wait will be showed at the right lower corner of the VFD display. When in pause mode, the word Stay will be showed at the right lower corner of the VFD display. When one test is finished, the test result Pass or Fail will be showed at the right lower corner of the VFD display. 17) When one test is finished, users can press the up-down keys to make one single step worked manually. At the moment, step n will be showed on the VFD display, indicating the step which is working; then Han is showed, indicating that the instrument is in hand-operated single step test state, followed by the test results being showed at the right lower corner of the VFD display. 4.7 Output On-Off Operation When in front-panel operation, you can press the key On/Off to control the output state. The key On/Off does not affect the present setting values. When the TRI is enable, the key On/Off is invalid. When TRI is in OFF state, the TRI can be used to switch the OFF/ON state. 4.8 Remote Measurement Function When the load consumes high current, the power supply will produce voltage drop in the connecting wire between power supply and load terminals. In order to guarantee the measurement accuracy, remote measurement terminals is installed at the rear-panel of the power supply. Users can measure the output terminals voltage of the instrument under test by these terminals. Before performing the remote measurement function, you need to set the power supply as the remote measurement mode. Please refer to the diagram 4.4 for the trigger terminals and measurement terminals. 23 YI-55 Series Programmable DC Power Supply Diagram 4.4 Remote Measurement Terminals -S and +S are remote measurement terminals; TRQ and TRI are trigger terminals, GND is ground terminal. The TRQ is trigger output port under auto test mode. The TRQ is default as low voltage level. The TRQ provides +5V for external use when the trigger event happens. As a multifunction extended port, TRI port is designed for trigger test in the list mode and auto test mode, TRI is also used to switch the ON/OFF state and used as TRI KeepOut port. The TRI is default as high voltage level of +5V. The TRI completes trigger when it change to low voltage level. 4.9 Milliohmmeter Function The power supply provides the four-line electrical resistance measurement, just as showed in following diagram 4.5, which can measure accurately the low resistance and the maximum measurement resistance is 10Ω. In order to avoid the damage of the resistance under test, please make sure the resistance under test is within the measurement range. Three measurement ranges can be optional: 0.1W, 1W, 10W. Operation Method: 1) Press the keys Shift and V/mΩ (VFD display screen shows----,----mΩ, Range:0.1W) to measure the resistance. 2) Press the keys Shift and 0.1W or 1W or 10W to set different measurement range of Milliohmmeter. Diagram 4.5 Milliohmmeter Measuring Resistance 24 YO IE ENTERPRISE CORP., LTD 4.10 Voltmeter Function The voltage of the instrument under test can be measured if the wires are connected together just as the diagram 4.6. The power supply can be worked as a voltmeter as long as it is not measuring the resistance.The accuracy of the voltmeter is 5 1/2. Diagram 4.6 Measuring the Voltage of the Instrument under Test 25 YI-55 Series Programmable DC Power Supply Chapter 5 Remote Operation Mode The DB9 interface connector on the rear panel of the power supply can be transferred to RS232 interface through the voltage level convertor cable (YI-131), the following information will tell you how to use the computer to control the output of the power supply. Before carrying out the remote operation mode, please use the voltage level converter cable (YI-131) provided by Maynuo Electronic to connect the DB9 interface connector of the power supply and the RS232 interface connector of the computer for the communication. The YI-131 aslo can be replaced by the YI-132(RS485) cable and YI-133(USB) cable for different application. 5.1 YI-131/ YI-132/ YI-133 Communication Cable The DB9 interface connector on the rear panel of power supply is TTL voltage level, you can use the communication cable (YI-131, YI-132 or YI-133) to connect the DB9 interface connector of the power supply with the computer’s interface for the communication. Please refer to the following figures for interface connector. Diagram 5.1 YI-131 26 YO IE ENTERPRISE CORP., LTD Diagram 5.2 YI-133 Diagram 5.3 YI-132 Note: It will not work if you connect the DB9 interface connector of the power supply to the RS232 interface connector of computer directly by a standard RS232 cable. Please use YI-131 to connect them. 27 YI-55 Series Programmable DC Power Supply 5.2 Communication between Power Supply and PC The DB9 interface connector on the rear panel of the power supply can be transferred to the interface connector of the computor through the voltage level converter cable (YI-131/ YI-132/ YI-133). The following instructions can help you understand how to control the output of power supply by PC. 1. Communication Setting Before using the remote operation mode, please make sure that the baudrate and communication address in power supply is the same as that in the computer software; otherwise, the communication will fail. You can change the baudrate and communication address from the front panel or from computer. (1) Baudrate: 9600(4800, 9600, 19200, 38400, which are selectable from the menu on the front panel of power supply). (2) Parity: NONE (NONE, EVEN, ODD) (3) Data bit: 8, Stop bit: 1(fixed value) 2. DB9 Serial Interface Diagram 5.4 DB9 Serial Interface The output of DB9 interface on the rear panel of the power supply is TTL voltage level, so the voltage level convertor cable(YI-131/ YI-132/ YI-133)must be applied before connecting the DB9 interface with the serial interface on PC. 3. The Difinition of the DB9 Interface One end of the YI-131/ YI-132/ YI-133 cable is TTL voltage level,which is connected to the power supply. Another end is different. The Difinition of the DB9 Interface as follows: Power Supply Side 1 2 3 4 5 6 7 8 9 TTL VCC(+5V) RXD(receive) TXD(send) NC GND(ground) NC NC NC NC 28 YO IE ENTERPRISE CORP., LTD PC side 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 1 2 3 4 YI-131(RS232) NC Notes: RXD ( receive ) The pin 4 and 7 are paralleled. TXD( send ) Each is prodvided +12V power. VCC1 GND(ground) NC VCC2 NC NC The pin 4 is provided +12V when the DTR is enable in process of programming. The pin 7 is provided +12V when the RTS is enable in process of programming. The DTR default is set enable in most serial communication controls. YI-132(RS485) A(+) Notes: B(-) NC NC GND (ground) Only to connect the pin 1 and pin 2 is able to get the RS485 communicate normally well. The pin 5 and pin 6 provides Vout(+5V) 5V/100Ma for external use. YI-133(USB) VCC(+5V) Notes: The type A interface of the -D standard USB can be directly +D connected USB interface of the GND PC. (ground) The USB driver can be installed. 29 YI-55 Series Programmable DC Power Supply Chapter 6 SCPI Communication Protocal 6.1 SCPI Communication Command Introduction YI-55 series programmable DC power supply supports SCPI communication protocol. SCPI communication protocol is a standard commands for programmable instruments, which defines a standard set of communication commands.Command for YI-55 series power supply can be divided into two categories: basic commands (IEEE-488.2 Common Command Set) and command specified by YI-55 series power supply. SCPI command is ordered arrangements of tree constructs. Each command contains a number of strings (mnemonic) . Layers separated by a colon (:). At the top of the command in the command tree known as the "root shell" or simply "root." Access to the next command, you must specify a path. Ordered tree is structured as follows: In the above table: AA represents the root path; BB, CC, DD represents the direct sub-path of root path AA. EE, FF, GG said that the path is a sub-sub-path under the BB. HH, JJ said that the path is a sub-sub-path under DD. Command description: 1) [:] AA: CC means the current root path for the AA, visit the CC under the AA. 2) [:] AA: BB: FF means the current root path for the AA, visit the FF of the sub-path BB under the AA. 3) [:] AA: DD: HH means the current root path for the AA, visit the HH of the sub-path DD under the AA. This command can send more than one order in a message and use a semicolon (;) between each order. Example: [:]AA:BB:EE;FF;GG means access to the EE, FF, GG under the BB. [:]AA:BB:FF;:AA:DD:HH means access to FF under the BB and HH under the DD. SCPI language mnemonic (keywords) has two farmat: long format and short format. Short format is actually short for long format. It uses the following rules: Short format mnemonic is the first four characters of long format mnemonic. If the length of the long-form mnemonic characters less than or equal to 4, then the long mnemonic is the same as 30 YO IE ENTERPRISE CORP., LTD short format mnemonic. If the length is greater than the length of 4 mnemonic, and the fourth character is a vowel, short mnemonic will discard the fourth vowel character and become three characters. Example: Short-type mnemonic of ERRor is ERR, rather than the ERRO. Some command needs parameters, for example, setting value command. There is a space (ASCII code is 32) between the command and the first parameter. Example: Setup voltage value command [:] VOLT 12.000 There is a space (ASCII code is 32) between 12.00 and VOLT. SCPI is case-insensitive, namely commands are not case sensitive and each command has an EOI end: Instruction end <LF> (that ASCII code character '\n', that is, line breaks decimal ASCII code 10, hex 0x0A). Note: All of the following commands to send back all require add <LF>. The following statement appears in [ ] represents the characters can be written in commands, or you can not write. 6.2 Command Introduction of YI-55 Power Supply 6.2.1 Basic command (IEEE-488.2 Common Command Set) Basic command includes all general functions in IEEE-488.2. These functions are usually applied to support the IEEE488.2 standard measuring instruments. The group command begin at an asterisk (*) and has no hierarchy. Command * IDN? Command * IDN is used to read the relative information of power supply, including manufacturer, product model number, serial number, and version number. Return command: return parameter contains four fields separated by comma(,). Example: Sending command * IDN?, the corresponding expressed as a hexadecimal is 0x2A 0x49 0x44 0x4E 0x3F 0x0A, if return command is MAYNUO, YI-5511, 080010960121229001, V1.0, it means: MAYNUO YI-5511 080010960121229001 V1.0 manufacturer product model number product serial number fireware version number 6.2.2 System Command Commands described in this section are under the root path [:] SYSTem commands. The following commands are used short-type mnemonic format. Command [:]SYSTem:ERRor? Command [:]SYSTem:ERRor is used to read the error code and error message. Return command: Error code, error message. 31 YI-55 Series Programmable DC Power Supply Example: If you send command [:]SYST: ERR?,then return command ought to be"0, 'No Error'", or "50, 'Error Para Count'", or "70, 'Invalid Command'" etc.. Command [:]SYSTem:REM Command [:]SYSTem:REM is used to set remote control mode, namely the PC control mode. Return command: None Example: If you send command [:]SYSTem:REM After sending command successfully, the power supply has been in the remote control mode , “REM” characters appears in the right corner front panel and the front panel operation is not valid. And please return the front panel control model by pressing the key Shift + the number 7, or sending the command [:] SYST: LOC. Command [:]SYSTem:LOC Command [:] SYSTem:LOC is used to set the front panel control mode. Return command: None Example: Sending command [:] SYST:LOC if the power supply in the remote control (PC) mode. After sending successfully, the power has been in the front panel control mode while “REM”disappears from the right corner of the front panel. Command [:]SYSTem:SENSe <bool> Command [:] SYSTem: SENSe <bool> is used to set the power is under remote measurement. Return command: None Parameters: bool-type parameter (0-OFF, 1-ON) Example: Sending command [:]SYST:SENS 1, if sending successfully, the power supply is set in the remote measurement. 6.2.3 Measurement Command Commands described in this section are under the root path [:]MEASure commands. The following commands are used short-type mnemonic format. Command [:]MEASure: VOLTage? Command [:]MEASure: VOLTage? is used to read output voltage value. Return command: Numeric Return parameters Unit: V Example: Sending command [:]MEAS: VOLT?, if return command is 12.560, it means the present output voltage is 12.560V. 32 YO IE ENTERPRISE CORP., LTD Command [:]MEASure:CURRent? Command [:]MEASure:CURRent? is used to read output current value. Return command: Numeric Return parameters Unit: A Example: Sending command [:]MEAS:CURR?, if return command is 1.245, it means the present output current is 1.245A. Command [:]MEASure:DVM? Command [:]MEASure: DVM? is used to read input voltage of the voltmeter in the power supply. Return command: Numerical Return parameters Unit: V Example: Sending command [:]MEAS:DVM?, if return command is12.560, it means the current voltmeter input voltage is 12.560V. Command [:]MEASure:VCM? Command [:]MEASure:VCM? is used to read three value: output voltage value, output current value, and input voltage of the voltmeter in the power supply. Return command: Numerical list, using cormer(,) among the three values Return parameters Unit: V and A Example: Sending command [:]MEAS:VCM?, if return command is 10.0000,0.00000,5.0000, it means the present output voltage is 10.0000V, the present output current is 0.00000A, and the current voltmeter input voltage is 5.0000V. 6.2.4 Setting Command Command [:]OUTPut <bool> 1.Command [:]OUTPut <bool> is used to set the output ON/OFF status. Return command: None Parameters: bool-type parameter (0-OFF, 1-ON) Example: If sending command [:]OUTP 1, the power supply output is ON if you set successfully. 2.Related command [:]OUTPut?, to query output status of power supply. Return command parameter: <bool>. Command [:] MODE <mode> 1. Command [:]MODE <mode> is used to set the power operating mode. That is, command set mode or sequential list mode, or milliohmmeter mode. Parameter: mode has three following modes, FIXed command set mode 33 YI-55 Series Programmable DC Power Supply LIST sequential list mode DRM milliohmmeter mode Return command: None Example: Sending command [:]MODE LIST, the power supply is in sequential list mode. 2. Related command [:] MODE?, to query working mode of power supply. Return command parameter: <mode> Command [:]VOLTage <Value> 1.This command is used to set the voltage value of power supply. Parameters: numeric |MAX|MIN Unit: V Return Command: None Example: 1) Sending command [:]VOLT 30 Means to set the voltage value of the power supply is 30V. 2) Sending command [:]VOLT MAX Providing the maximum output voltage is 76.000V, it means to set the voltage value is the maximum voltage 76.000V. 3) Sending command [:]VOLT MIN Providing the minimum output voltage is 0.000V, it means to set the voltage value is the minimum voltage 0.000V. 2.Related Command [:]VOLT? MAX|MIN, the command is used to query the setup voltage value, the maximu setup voltage value and the minimum setup voltage value. Return command parameters: numeric Example: 1) If you want to query the setup voltage value, please send command [:]VOLT?, if the return command is 10.0000, it means the setup voltage of power supply is 10.0000V. 2) If you want to query the maximum setup voltage value, please send command [:]VOLT? MAX, if the return command is76.0000, it means the maximum setup voltage value of power supply is 76.0000V. 3) If you want to query the minimum setup voltage value, please send command [:]VOLT? MIN, if the return command is 0.0000, it means the minimum setup voltage value of the power supply is 0.0000V. Command [:]CURRent <Value> 1. This command is used to set the current value. Parameters: numeric |MAX|MIN Unit: A Return command: none Example: 34 YO IE ENTERPRISE CORP., LTD 1) Sending command [:]CURR 3, it means to set the current value as 3A. 2) Sending command [:]CURR MAX Providing the maximum setup current value of the power supply is 2.0000A, it means to set the present current value as the maximum current value 2.0000A. 3) Command sent [:]CURR MIN Providing the current minimum setup current is 0.0000A, it means to set the present current as the minimum current 0.0000 A. 2.Related Command [:]CURR? MAX|MIN, the command used to query the setup current value, the maximum setup current value and the minimum setup current value Return command parameters: numerical value Example: 1) If you want to query the setup current value, please send command [:]CURR?, if the return command is 1.0000,it means the setup current of power supply is 1.0000A. 2) If you want to query the maximum setup current value, please send command [:]CURR? MAX, if the return command is 2.0000, it means the maximum setup current value of power supply is 2.0000A. 3) If you want to query the minimum setup current value, please send command [:]CURR? MIN, if the return command is 0.0000, it means the minimum setup current value of the power supply is 0.0000A. Command [:]VOLTage:PROTection <Value> 1. This command is used to set the upper limit voltage of the power supply, namely the maximum output voltage. Parameters: numeric |MAX|MIN Unit: V Return command: none Example: 1) If sending command [:]VOLT:PROT 30, it means to set 30.000V as the upper limit voltage of the power supply. 2) If sending command [:]VOLT:PROT MAX, it means to set the upper limit voltage as the maximum output voltage value of the power supply. 3) If sending command [:]VOLT:PROT MIN, it means to set the upper limit voltage as the minimum output voltage value of the power supply. 2. Related command [:]VOLTage:PROTection? [MAX], it means to query the upper limit voltage Return command parameters: numerical value Example: 1)If sending command [:]VOLT:PROT?, If the return command is 20.000, it means the upper limit voltage of the power supply is 20.000V. 2)If sending command [:]VOLT:PROT? MAX, If the return command is 76.000, it means the maximum setup voltage value of the power supply is 76.000V. 35 YI-55 Series Programmable DC Power Supply 6.2.5 List Operation Related Command Command [:]LIST:AREA <num> 1. This command is used to set the list location division mode. Parameter: 1|2|4|8 1. Set 1 file of 200 list steps in the list operation 2. Set 2 files of 100 list steps in the list operation 4. Set 4 files of 50 list steps in the list operation 8. Set 8 files of 25 list steps in the list operation Example: If sending command sent [:]LIST:AREA 8, it means to set 8 files of 25 list steps. 2. Related command [:]LIST:AREA?, it means to query the location division mode of the list operation. Return parameters: <num> Command [:]LIST:RCL <num> This command is used to recall the saved files from a certain location so as to make them executed in the list. Parameter: 1~8 Return command: none Example: If sendin command [:]LIST:RCL 2, it means to recall the list file from the storage register location 2 and make the file executed. Command [:]LIST:COUNt <count> 1.This command is used to set the step number of list. Parameter: count range : 1~200 Return command: none Example: If sending command [:]LIST:COUN 20, it means the step number of the list is set as 20. 2.Related command [:]LIST:COUNt?, it means to query the step number of the current list. Return parameter:<count> Command [:]LIST:MODE <mode> 1. This command is used to set the working mode of the list. Parameters: mode has 3 types: CONTinuous: continuous mode STEP: 1 step mode (once mode) LOOP: loop mode Return command: none 36 YO IE ENTERPRISE CORP., LTD Example: If sending command [:]LIST:MODE CONT, it means the working mode of list files is set as continuous mode. 2. Related command [:]LIST:MODE?, it means to query the working mode of the current list. Return parameters: <mode> Command [:]LIST:VOLTage <count>,<value> 1. This command is used to set the setup voltage value of the appointed step in the list. Parameter: count is appointed step number; value is the setup voltage. Unit: V Return command: none Example: If sending command [:]LIST:VOLT 1,5, it means to set the setup voltage value of the first step of the list file as 5.000V. 2. Related command [:]LIST:VOLTage? <count>, it means to query the setup voltage value of the appointed step in the list. Return parameters:<value> Example: If sending command [:]LIST:VOLT? 1, it means to query the setup voltage value of the first step in the current list. Command [:]LIST:CURRent <count>,<value> 1.This command is used to setup current value of the appointed step in the list. Parameters: count is appointed step number; value is the setup current. Unit: A Return command: none Example: If sending command [:]LIST:CURR 1,2, it means to set the setup current value of the first step in the list as 2.000A. 2. Related command [:]LIST:CURRent? <count>, it means to query the setup current value of the appointed step in the list. Return parameter: <value> Example: If sending command [:]LIST:CURR? 1, it means to query the setup current value of the first step in the current list. Command [:]LIST:WIDTh <count>,<time> 1. This command is used to set the delay time of the appointed step in the list. Parameters: count is the appointed step number; time is the setup delay time. Unit: mS 37 YI-55 Series Programmable DC Power Supply Return command: none Example: If sending command [:]LIST:WIDT 1,2000, it means to set the delay time of the first step of the list file as 2000mS. 2. Related command [:]LIST:WIDTh? <count>, it means to query the delay time of the appointed step in the current list. Return parameters: <time> 38 YO IE ENTERPRISE CORP., LTD Quick Reference Safety Please donot install any spare or repair the instrument without permission. In order to make sure the normal work of the instrument, please have it mended in the maintenance department designated by our company. Pease review the following safety precautions before operating our equipment. Safety Symbols Please keep in mind the following items which may result in injuries on your body. Connect it to safety earth ground using the wire recommended in the user manual. High voltage danger (Non-professionals are forbidden to open the instrument) The symbol on an instrument indicates that the user should refer to the operating Instructions located in the manual. Certification and Warranty YI-55 series power supply meet its published specifications at time of shipment from the factory. Warranty This instrument product is warranted against defects in material and workmanship for a period of one year from date of delivery. Maintenance Service This product must be returned to maintenance department designated by our company for repairing. Customer shall prepay shipping charges (and shall pay all duty and taxes) for products returned to the supply for warranty service. Except for products returned to customer from another country, supply shall pay for return of products to customer. Limitation of Warranty The foregoing warranty shall not apply to 1. Defects resulting from improper or inadequate maintenance by the Customer, 2. Customer-supplied software or interfacing, 3. Unauthorized modification or misuse, 4. Operation outside of the environmental specifications for the product, or improper site preparation and maintenance. 5. Defects resulting from the circuit installed by clients themselves Attention No inform will be given for any changes in the content of the user’s guide. 39 ">
Advertisement
Key features
- High performance single-output programmable DC power supply
- Fast rise time speed
- Built-in high-accuracy 5 1/2 voltmeter and milliohmmeter
- Supporting high-accuracy and dynamic programming output
- High-luminance VFD screen and two lines& four ways display
- Smart fan for automatic temperature control
- Supporting remote voltage compensation and multidata storage
- Supporting external trigger input and output
- Power-on-self-test, software calibration and standard rack mountable
- Supporting RS232/RS485/USB interface