Methven ECSRSQCP Easy-Click 3 Function Rail Shower Installation Sheet
Advertisement
Advertisement
HANDSET
Installation Guide
Technical Specifications:
Operating Pressure:
Min: 150kPa/1.5bar
Max: 500kPa/5bar*
Operating Temperature:
Hot: Max 70°C*
Cold: Min 5°C
Inlet Connections:
½" BSP
* Regional specific regulations apply.
Please refer to your warranty statement at www.methven.com
www.methven.com
•
•
•
•
•
IMPORTANT: Please read all of the instructions before installation.
General:
• Methven recommends this product is installed by a licensed plumber in compliance with all relevant regional regulations.
After installation all connections must be checked for leaks.
All outlets used primarily for personal hygiene shall deliver water at a safe temperature as per regional regulations.
It is the responsibility of the installer to ensure a waterproof seal is achieved.
NOTE: Some showers may not provide an effective shower when used with gravity fed heated water systems or where pressures are less than 150kPa/1.5bar at the outlet. Additionally showers with flow rates of less than 9L/min may not allow the following to function correctly:
- some instantaneous water heaters
- some tempering valves
- some thermostatic mixing valves Handset
Step 1
Connect hose to outlet bracket and handset.
Flat
Washer
Care and Cleaning:
Never use abrasives or abrasive cleaning agents to clean this product. Clean regularly with contamination free warm soapy water and a damp soft cloth.
A filter washer should be installed in the hose cone on the water outlet and it should be cleaned periodically.
If shower performance is compromised by the build-up of lime-scale, soak in limescale remover for up to 10 minutes. Do not use products containing chlorine bleach or hydrochloric acid as these can damage the shower. Always rinse the shower thoroughly after cleaning to remove cleaning products that can damage the shower.
Never insert objects into the spray nozzles or attempt to remove limescale with sharp objects or abrasives.
Methven warrants this product against manufacturing defects and that it is suitable for use under the general operating conditions specified in this instruction sheet. However, regional regulations apply and may affect your warranty. Please refer to www.methven.com
or call customer service for full details.
New Zealand
0800 804 222
Australia
1300 638 483
UK
0800 195 1602
98-0314 ISSUE A
DECEMBER 2015
Elbow Installation (if supplied):
•
•
Step 1
Wall lining hole should be cut or finished as per the dimension shown in the diagram on the right.
Cut off the threaded nipple 13±2mm from the wall lining and apply thread seal tape to ensure a good seal.
•
•
Step 2
Screw the elbow onto the nipple ensuring that the o-ring is sufficiently compressed to create a watertight seal.
Ensure that the elbow is oriented vertically with the outlet oriented downwards.
13±2mm
26mm max
Care and Cleaning:
Never use abrasives or abrasive cleaning agents to clean this product. Clean regularly with contamination free warm soapy water and a damp soft cloth.
Periodically the filter washer should be removed from the end of the shower hose and cleaned.
SOFT SQUARE RAIL
Installation Guide
Technical Specifications:
Inlet Connections:
All ½" BSP
* Regional specific regulations apply.
Please refer to your warranty statement at www.methven.com
Methven warrants this product against manufacturing defects and that it is suitable for use under the general operating conditions specified in this instruction sheet. However, regional regulations apply and may affect your warranty. Please refer to www.methven.com
or call customer service for full details.
New Zealand Australia
439993
UK
ISSUE A
www.methven.com
IMPORTANT: Please read all of the instructions before installation.
General:
• This product must be installed in compliance with all relevant regional regulations.
• It is the responsibility of the installer to ensure a waterproof seal is achieved between the product and mounting surface. If in doubt about the quality of the seal, remove the product and reinstall using silicone to ensure a seal is achieved.
•
•
•
All pipe work must be thoroughly flushed prior to the installation of the hose.
After installation all connections must be checked for leaks.
All outlets used primarily for personal hygiene shall deliver water at a safe temperature as per regional regulations.
Wall Screw
Tensioning Screw
Slider
Elbow
(if supplied)
Wall Mounting
Plate
Rail
Bracket
Rail
Wall Plug
Grub Screw
•
Step 1
Mount the wall mounting plates in the desired position with the screws. Check the mounts are vertically aligned.
Ensure the grub screws are located on the correct sides as shown.
Grub Screw
Topside
Grub Screw
Underside
Step 2
•
•
•
•
•
Set location of rail bracket on the rail and loosely tighten the tensioning screws.
Align the rail brackets to the wall mounting plates and push into place.
Slide the rail up or down to centralise the brackets.
Remove the rail and tighten the tensioning screws firmly.
Relocate the rail onto the wall mounting plates and tighten the upper and lower grub screws.
•
Step 3
To adjust slider position, rotate the slider handle to unlock and lock the slider as shown.
Unlock
FLOOR
Lock