Ord.code: FMS037-TV02
User’s manual
Caution
Content of this manual is protected by the copyright and may not be duplicated or copied in any form,
either partially or as a whole without the prior written consent of the owner. Usage of the product is in
defiance of with the manual will result to the loss of the warranty or product liability or refuse
responsibility for product by manufacturer. Author of this user‘s manual is thankful for any
suggestions for its improvement.
Following underlined terms used in this manual have the following meanings:
Caution
Applies to the technical requirements to be respected by the user to ensure perfect functionality of the
device.
Attention
Refers to the instructions, that has to be precisely followed to avoid damage or destroy the device.
Warning
Refers to the instructions, which failure can jeopardize the operation of the device.
Date: 27.03.2014
Page 1 / 14
NU_FMS037-TV02_000_27032014_EN
1.
Safety precautions
Before working with FMS037-TV02 please read carefully following safety precautions !
Attention
The receiver can be opened only by qualified technician. Before they start to perform
service tasks, the receiver has to be disconnected from the power supply. In the opened
device can be accessed parts, which can be under dangerous voltage and contact with
them can be life-threatening. Any exchange of the component and/or installation of any
module can be performed only when the receiver is disconnected from the power supply!
In case of power failure remain all data stored in the memory of the receiver.
Power supply 12V/24V
Device can be operated only in specified voltage range from +9 to +36V DC.
Connecting cabling
All cabling leading to and from the receiver are necessary to place transitional or other
moldings and that mainly in the places, where is expected that people will be moving!
Humidity and place of installation
Device cannot be exposed to tripping or splashing water.
In case of occuring condesating water wait, until the water from the device will totally evaporate and
after that you can connect again to the power supply.
Ambient temperature and heat influence
Ambient temperature during operation should not exceed +85°C. Ventilating devices cannot be in any
way obstructed, so the ventilation of the receiver will be sufficient. Accumulation of the heat in the
receiver may negatively effect the lifetime of the device and may be the source of the danger. Device
cannot be installed directly over the source of heat or nearby (e.g. heating elements, heating systems
or similar devices), where it would be exposed to the thermal radiation or oil vapor. It is
recommended, that the device is installed on the non-combustible base.
Measurements to ensuring of electro-magnetic compatibility (EMC)
All covers and screws has to be firmly mounted and fixed. Contact areas should not be oxidated or
deformed.
Caution
This receiver has to be equipped with the ESD components (ESD = Electrostatic Sensitive
Device) !
Electrostatic discharge are electrical current pulses, which can start with the large voltage
variations and also via standard insulating materials.
When installing and handling ESD components need to follow these important rules:
Electrostaticaly sensitive devices may be operated only on electrostaticaly protected areas
(EPA) !
Ensure continual balancing of electric potential !
Ensure the correct grounding of the persons / workers with the grounding bracelets and
grounding shoes !
Avoid using electrostatic rechargeable materials such as PE, PVC, polystyrene and other !
Avoid electrostatic fields >100V/cm !
Use only marked and defined packaging and transport materials !
On damages resulting from incorrect connection caused by improper connection
and/or improper handling are not covered by warranty!
Date: 27.03.2014
Page 2 / 14
NU_FMS037-TV02_000_27032014_EN
2.
Receiver description
DVB-S receiver FMS037-TV02 is designed for two two-channel receivers / modules PSTI series. This
ensures reception up to 4TV channels and their integration to MOD system FUNTORO. Internal
construction and power supply in range 9 - 35V DC predestinate this device for usage in the means of
transport.
2.1
Module description
Receiver module PSTI serves for reception of DVB-S TV signal coded in QPSK into two independent
AV signals. Subsequently are these signals converted to digital stream suitable for MOD system
FUNTORO. Output AV signals are brought out with Sub-D connectors.
Two independent tuners of each module PSTI supports parallel conversion of two different MPEG2 data
streams. In case of usage only one output data stream is tuner B set to mode „slave“ and its antennas
input can be deactivated, thereby achieving lower power consumption. Each PSTI module is equipped
with standard CI (Common Interface) slot, that enables usage of CA module for decoding Smart card.
One CA module with one Smart card can decode two TV programmes at the same time.
!! Basic condition for programming DVB-S receiver is its connection on antenna and setting of
requested satellite !
2.2
Connecting of the PSTI modules
Input A
Output A
LED indication
Input B
Output B
Date: 27.03.2014
Page 3 / 14
NU_FMS037-TV02_000_27032014
2.3
LED indication
LNB/5 voltage
Signal
LED indication
TURNED OFF
OK
Green
TURNED OFF
NOT OK
Green flashing
TURNED ON
OK
Orange
TURNED ON
NOT OK
Red/Orange flashing
2.4
Installing a new module or replacement
Insert CAM module to edge molding and insert firmly to connector on the backside and subsequently
Smart–card. Then fasten the CAM module cover using the crosscrews on the front panel. For
replacement of the module or only Smart card loosen the cross screws, remove the module cover and
take out the card/ module. Then insert new card/ module.
2.5
Programming process of PSTI modules
After the insertion of CAM modules and Smart-cards for reception of coded programs has to be basic
unit and modulators programmed in accordance with attached instructions.
Manual programming of digital modules is performed subsequently:
Connect antenna, whereby measuring device with the screen or TV on RF output of the end
station – Reason is: part of the screen is indicated on the screen menu.
Module of the program modulator on the requested channel output in accordance with the
attached instructions. On programming of digital module has to be measuring device and/or
screen set to the particular output of the modulator channel.
(In the double modulators, first channel. And also showing the parameters of the second digital
channel)
Program the digital modules in accordance with program sequence shown on the following
pages. Note, that program sequence corresponds to the selected base unit. Selection and
confirmation of the operational steps is performed using the keyboard below the screen.
Warning
During the programming process are programming references displayed on the base unit and
also on-screen display!
After changing of the card location or data transfer using the button CopyKey, data needs to be
confirmed again.
Warning
Minimal required software version of the base unit for flawless programming is
specified on module.
Date: 27.03.2014
Page 4 / 14
NU_FMS037-TV02_000_27032014_EN
3.
Programming
Programming of the unit is carried out with keypad located between the display and USB port on the
right side od DVB-S receiver.
Plus / move to the line on the
display upwards
Previous / next
number
Confirm / Continue
Minus / move to the line on
the display downwards
Buttons
are used for selection and confirmation of the operation steps for
setting of the values. After turning on the unit. (connection to power supply) are loaded all data and
may be set. This process (data loading) lasts up to 15 seconds.
Insert the card reader to the module and after that insert card Smart-card.
Date: 27.03.2014
Page 5 / 14
NU_FMS037-TV02_000_27032014_EN
Compact Headend
SPM200 DIGI D.9
Software version
Keep pressed, until the change on the display will
show up.
Program
Service
Program selection or service menu
PL01 PSTI
PL02 PSTI
Choose slot of the module (PL1=upper,
PL2=bottom)
Select Path
Path A
Channel selection, that is set (A or B)
S/W Version:
V 1.12
Shows software version of TV card
Operation Mode
Master
Only for channel B – tuner selection B master /
slave
LNB Control Menu
18V / 22kHz
Input frequency
1237 MHz
Set input SR
27500 KSym
Searching ...
Select program
BBC
Date: 27.03.2014
Selection LNB remote source of voltage (13V, 18V,
13V/22kHz, 18V/22kHz, DiSEQC, OFF)
*
Input frequency (950~2150MHz)
underlined number with
.
Symbol rate
Searching
set with cursor
* Display of the receiver has limited
number of digits and that s why it is
necessary at setting from the value on the
really broadcasted frequency:
at HB 10600MHz
at LB 9650
and on the display of the receiver to set
this calculated value!
Choose radio or TV channel
Page 6 / 14
NU_FMS037-TV02_000_27032014_EN
Select Language
German
Language selection (if available)
Teletext
off
Select Subtitle
off
Subtitles selection (if available)
Audio Level
-3 dB
Selection of audio level (-6, -3, 0, +3, +6)
Screen Type
Auto
Selection of screen type (16:9, 4:3, automatic, off)
Edit CAM-Menu
No
If it is available menu CAM choose editing (No, Yes)
Confirm settings
from OSD
PL01 PSTI
PL02 PSTI
Settings confirmation
Return to the main menu
In case of power failure all data will remain stored in the unit!
Date: 27.03.2014
Page 7 / 14
NU_FMS037-TV02_000_27032014_EN
3.1
Technical data PSTI
RF – input
Connection (connector)
Frequency range
Tuning (steps)
2 x F / 75Ω
950 ~ 2150MHz
1-MHz
Input level
47 ~ 70dBµV
Bandwidth
automatic
Modulation
QPSK
Symbol rate QPSK
FEC
Code rate Viterbi
40MBit/s (MCPC + SCPC)
in accordance with DBV
1/2, 2/3, 3/4, 5/6, 7/8, 8/9
(automatic switching)
Output (to modulator)
Connection
Video level
Video bandwidth
Audio level
Audio bandwidth
Power consumption (typical without CI)
Date: 27.03.2014
15-pin SUB-D female
1Vpp/75Ω
(1-dB-step, 0 ~ -3dB)
20Hz ~ 5MHz
1Vpp/10Ω
(3-dB-step, -6dB ~ +6dB)
40Hz ~ 15kHz
7W
Page 8 / 14
NU_FMS037-TV02_000_27032014_EN
3.2
Unit firmware update with USB flash disc
Request latest version of firmware from the MOLPIR helpdesk!
Copy the file on the USB-flash disc
Insert USB-flash disc to USB port of the unit located under the display and 4 buttons on the
right side of the receiver
Open the update menu (shown below)
Confirm the start of the update
Wait until the update will be finished
Remove USB-flash disc from the port
Buttons
are used for selection and confirmation of the operation steps for
value settings. After turning on of the unit (connecting to power supply) are all data loaded and can
be set. This process (data loading) can last up to 15 seconds.
Attention
If firmware will not recognize the new module in slot or module, in case module will be not displayed
or otherwise module cannot be displayed at all on the display (skipped) after that firmware has to be
upgraded to the latest version.
Insert USB to the slot under the adjustement buttons
Date: 27.03.2014
Page 9 / 14
NU_FMS037-TV02_000_27032014_EN
Update - process
Compact Headend
SPM200 DIGI D.9
Stand-by mode
Program
Service
Use buttons
to switch „Service“
Service
Program
Reset
Copy Settings
With buttons
switch to „Update“
Update
Temperature
Please Insert
USB-Stick
Please wait ...
Update running
Compact Headend
SPM200 DIGI D.9
Update was OK – remove the USB from slot under the adjustment buttons.
Date: 27.03.2014
Page 10 / 14
NU_FMS037-TV02_000_27032014_EN
3.3
Loading of default settings (defaults)
Default settings of the unit can be restored anytime with service menu.
Compact Headend
SPM200 DIGI D.9
Program
Service
Use buttons
to switch „Service“
Chose Reset
Service
Program
Reset
Copy Settings
Restoring in operation
(display is flashing)
Confirmation of
restoration of default
settings by pressing the
button YES
Restore Defaults
Yes
Restoring
Factory Settings
Compact Headend
Loading Data ...
Back to stand-by
mode
Dátum: 27.03.2014
Compact Headend
SPM200 DIGI D.9
Page 11 / 14
NU_FMS037-TV02_000_27032014_EN
4.
Drilling plan of fixing holes and main dimensions
Date: 27.03.2014
Page 12 / 14
NU_FMS037-TV02_000_27032014_EN
5.
Technical data
Application
Car and railway industry
Number of plug-in slots
2
Operating voltage range
12V ~ 35 V DC
Max. current consumption
Operating temperature
-20°C ~ +85°C
Main dimensions (W x D x H)
6.
Scheme of connection
3A
373.5 x 177.5 x 124 mm
Detail „A“
Detail „B“
Detail „C“
Date: 27.03.2014
Page 13 / 14
NU_FMS037-TV02_000_27032014_EN
DVB-S receiver
„C“
„A“
IDU unit
CBM0000021
„B“
Power Box
CBM1000010
FMS-CA06-xxxxx
Hub
1 2 3 .. X (with other HUB)
Antenna – ODU unit
Date: 27.03.2014
Note ! Specification may be changed without notice.
Page 14 / 14
NU_FMS037-TV02_000_27032014_EN
Download PDF