Faton FA330H User Manual
Faton FA330H is a 4-stage air purifier designed to improve indoor air quality. It features a fiber filter to trap larger particles like pollen, a HEPA filter to remove 99.97% of particles as small as 0.3 microns, an activated carbon filter to absorb odors and harmful gases, and an anion generator to release negative ions. With its auto mode, the FA330H can automatically adjust its fan speed based on air quality, and it also has a timer function for added convenience.
Advertisement
Advertisement
Air Purifier
USER MANUAL
MODEL: FA330H
Please read the user manual carefuly before use. And please keep it properly after reading for checking in the future.
2
USER MANUAL
CONTENTS
USER MANUAL
1 Safety precautions
2 Product introduction
Function description of control panel.
3 Before use
Learning about air quality indicator light
Disassembly and installation methods of the back cover
Placement of air purifier
Install filter net
4 Purification principle
5 How to use
Function description of control panel.
Turn on the air purifier
Manual adjustment of wind speed
Timer mode
Child-lock function
Photosensitive sensor
6 Maintenance and cleaning methods
Clean the air purifier
Clean air quality sensor
Change filter
Long term idling
Referring time for filter replacement
7 Fault handing
Warranty and service
Order parts or accessories
Fittings
14
14
14
14
12
13
13
13
9
10
8
9
7
8
4
6
18
18
19
20
15
15
15
16
20
20
3
4
USER MANUAL
1. Safety precautions
In order to avoid possible damage to you, others or any property, please make sure to pay attention to the following safety precautions.
If the machine power line is out of order, you must entrust machine manufacturer, maintenance service center or qualified technicians to replace it to keep danger away.
Wet hand
Forbidden
WARNING
Do not touch power plug with wet hands.
Or else may cause electric shock.
Forbidden!
Prohibited to use beyond power or connected devices beyond specified value. Only can use
220V-alternating current (AC ) power supply
Overheating and fire accident may occur if you use universal socket or devices beyond specified value.
No damage to power line and socket.
Forbidden!
Do not bind wires when you use this machine. it may cause electric shock, short circuit and fire accident if you use broken wires.
Any cutting and scratching , refitting , over distor ting, twisting, screwing and pulling of lines are all forbidden. Do not put any heavy product on wires and sockets.
Do not take apart or modify the air purifier without authorization.
Taking apart is forbidden!
Taking apart or modifying air purifier without au thorization may cause electric shock, alfunction or fire accident.
Unplug!
Please make sure to turn off the power before cleaning machine.
Else it may cause machine sudden running and further electric shock accident.
Please insert the plug completely into the power socket before starting the air purifier. If not, it may cause electric shock and overheating, even fire accident.
Do not use damaged plug or loose power socket.
Regularly clean power plug
If dust accumulating on power plug, the dampness will make damage to insulation part of the plug , thus causing fire accident.
Pull out the power plug and then clean with dry cloth( do not use wet cloth).
If the machine will be of no use for long time, please unplug it.
Do not put bars or metal products nearby air outlet or openings.
Forbidden!
Else it may touch the internal parts and get an electric shock or damage.
USER MANUAL
Notice
Please turn off the power immediately in case of any of the following situations:
• Malfunction of any swtich;
• Circuit breaker worked or fuse burned
• Anomal heating of wires or plugs
• Any burnt smell, anomal sound or shock
• Any other anomaly or malfunction
ATTENTION
Forbidden!
Do not use solvent like benzene, diluent,etc. to clean air purifier. keep the machine away from wasp spray
Or else air purifier may broke into damage even short circuit occurs which can lead electric shock or fire accident.
Do not use air purifier in the situ ation of greasy particle.
Forbidden!
For example kitchen which can reduce the service life of air purifier filter.
This machine should not be used as ventilating or air evacuating equipment.
Forbidden!
Do not use the air purifier in the room with fumigation type pesticides.
Chemical residue could be accumulated inside the machine and then release from the outlet, making harm to health.
The room should keep ventilated thoroughly after you use insecticide and then start to use air purifier.
Wetting forbidden!
Keep machine body dry
Or else it may cause electric shock or fire acci dent because of short circuit.
Hold the plug when you take out the power plug and do not pull wires which may cause short circuit or damage to wires to avoid fire accident and electric shock.
If the air purifier works together with electric heater, the room should keep ventilation.
Or else there may be carbon monoxide poisoning accident.
The air purifier cannot clear off carbon monoxide.
Verboden te plassen!
Do not use air purifier in high temperature, humid conditions like bath room, as these situations may cause current leakage which can lead electric shock or fire accident.
Keep away from flame!
Keep the machine away from volatile substances or flamma ble items such as tobacco and sparks;
Or else it may cause fire accident
5
6
USER MANUAL
2. Product introduction
Indicator light of air quality
Air inlet
Air outlet
Front panel
Control panel
Handle
Air quality sensor
Back cover
HEPA filter and Activated carbon filter
USER MANUAL
Function description of control panel
Indicator light of
Child-lock
1 h,2h,4h,8h
Timing indicator
Light hole
Indicator light of
AUTO mode
Indicator light of filter replacement
High Speed
Low
Speed
Medium
Speed
Indicator light of
ANION
Child-lock Timer button Speed button
ON/OFF button
ANION button
7
8
USER MANUAL
3. Before use
Learning about air quality indicator light
Air quality indicator reflects the current air quality condition.
Indicator light of air quality
Hint
Considering power consumption, air quality sensor doesn’t work in ready mode.
Indicator lights color of air purifier
Blue Good
Green Ordinary
Red Poor
USER MANUAL
Disassembly and installation methods of the back cover
1 Disassembly method of the back cover
Press play button in the back cover and pull the cover, then you can lift the back cover and pull out slightly.
Placement of air purifier
To make sure good air circulation effect, please ensure there is 50cm distance between air inlet and wall or curtain. Besides, the distance to air outlet is not less than
50cm.
Please keep 1 meter or more distance from TV, Radio. Please do not use the same socket with TV, radio and other appliances which can avoid picture flutter or noise.
It may make wall surface around machine body dirty if you place the machine in the same place for a long time.
Do not obstruct air inlet and outlet, ensuring enough ventilation and high efficiency.
2 Installation method of the back cover
To reinstall the back cover, please align at the fixed groove and insert the cover into the groove, making the play button and frame withhold.
9
10
USER MANUAL
Install filter net
Information
All the filters are equipped with the puri fier together, you should remove all the packings of the filter before use. Please disassemble filters according to the follo wing instructions, reinstall the filter to air purifier.
Attention
Make sure power plug is outage when do installation, maintenance or transportation work. Do not use the machine without filter. Please remove all packages of filtes before use.
Hint
Make machine stick close to wall surface for realiability when you remove or insert filters.
Operation steps
Operate in accordance with the following steps to ensure correct filter installation when you first use this machine.
1 Place the machine in a dry, smooth and flat ground.
2 Press play button in the back cover and pull the cover, then you can lift the back cover and pull out slightly.
3 Disassemble all the filters.
USER MANUAL
4 Remove all package of the filter nets.
Hint
Please be careful when install the back cover, watch your hands.
5 Replace filters into the air purifier.
6 To reinstall the back cover, please align at the fixed groove and insert the cover into the groove, making the play button and frame withhold.
11
12
USER MANUAL
4. Purification principle
The purifier adopted passive adsorption and active type at the same time. The air absorb into the air purifier by motor. and through the filters and anion generator, then send out of purifier.lt can filter dust.
Remove formaldehyde and eliminate peculiar smell. And anion generator can generate air negative ions, also known as air vitamin.
Second step:
High efficiency HEPA filter
High efficiency HEPA filter is specially focused on particle with dia .bigger than
0.25 micron.
Third step:
Activated carbon filter
4 steps filter purification
First step: Fibre filter
Second step : High efficiency HEPA filter
Third step: Activated carbon filter
Fourth step: Anion generator
First step: Fibre filter
Can absorb volatile organic compounds and further remove toxic substances such as formaldehyde and other peculiar smell.
Fourth step:
Anion generator
Infiltrate the fibre filter with Natural anti bacterial, Anti-allergy elements, can effectively restrain the allergen like pollen.
Function: can effectively restrain the allergen like pollen.
Anion generator can produce negative ions, make the dust,bacteria,spores,pollen, dander and other particles charged,then it will be absorbed by integrated discharge device, it can remove PM2.5.
And anion can also activate oxygen molecules in the air to form negative oxygen ion, help human to get fresh air.
USER MANUAL
5. How to use
Function description of control panel
Plug in Turn on the air purifier
After plugged in the power, purifier will send out a siren, all the indicator will flash three times . Then, the power light will flash slowly.
Press ON/OFF button, purifier enters
AUTO mode. The indicator light of AUTO mode and power light will be on.
Indicator light of air quality will show green colour when the purifier turn on, after 2 min’s preheating, it will detect the air quality automatically.
Hint
Please press ON/OFF button for 5s to turn off the machine. With a siren the power light will flash, then pull out the power plug.
13
14
USER MANUAL
Press ANION button, with beeps ,anion function will work, and the indicator light of
ANION will be on.
Press ANION button again, the purifier will out of anion function, the indicator light of
ANION will be off.
Child-lock function
Press SPEED button, you can choose air speed in turn ‘AUTO mode, speed 1, speed 2 and speed 3’.
Under AUTO mode, the purifier will choose wind speed automatically according to the air quality.
TIMER mode
Press the Child-lock button for 3s, with beeps the indicator light of Child-lock will be on. In this condition, the purifier won’t be action when you press any key (except
Child-lock button).
Photosensitive sensor
Press TIMER button, the working hour will be option circulatory in 1 h,2h ,4h,8h,and no timer.
ANION mode
Under AUTO mode, if the lighting in the room is dark the air purifier will enter
SLEEP mode. Then all the indicator lights will be off except the power light. The fan speed change to low speed.
USER MANUAL
6. Maintenance and cleaning method
Please make sure to pull out power plug before cleaning the machine. Do not immerse machine in water or any other liquid. Do not use any detergent with abrasiveness, corrosive or inflammability( such as bleach or alcohol) to clean any parts of the product. The purifier use composite filters, the filters cannot be wash.
1 Use soft brush to clean inlet and outlet of air quality sensor.
2 Disassemble the cover of air quality sensor.
Clean the air purifier
Clean the air purifier regularly to prevent the dust accumulation.
1 Use soft and dry clothes to remove the dust from the air purifier.
2 Use soft and dry clothes to clean the outlet and inlet of the air purifier.
Clean the air quality sensor
Clean air quality sensor every two-month to ensure best running performance.
Please clean often if machine works in dusty environment.
Attention
When the room is in high humidity, air quality sensor may force condensate water in surface. In this condition, even the air quality is good, air quality sensor may show poor air quality, so you must clean air quality sensor or set manually.
3 Use dry swab to clean the air quality sensor, air inlet and outlet.
4 Reinstall the cover of air quality sensor.
15
16
USER MANUAL
Change filter
Information
Operating steps
1 The machine remind to replace the filters.
If the indicator light of filter replacement is on, it is to remind users to change the filters.
Attention
Please turn off and pull out power plug before replacing the filters.
Hint
Please remove the package of each filter before putting them into the machine and please make the label of filter face upward
2 Turn off the power, then pull out the power plug.
3 Press play button in the back cover and pull the cover, then you can lift the back cover and pull out slightly.
USER MANUAL
4 Remove all the filters assembly.
7 When the filter replacement is comple ted, plug in and turn on the air purifier, press the SPEED button and ANION button for 3s to reset the machine.
5 Remove all packages of filters, then install the new filters into the air purifier in order.
6 To reinstall the back cover, please align at the fixed groove and insert the cover into the groove, making the play button and frame withhold.
17
18
USER MANUAL
Long term idling
Pull out power plug( there is also power consumption in stand by mode)
Dry machine inside thoroughly (else there maybe malfunction because of rust)
Place the machine in dry and ventilating place (do not place flat or upside down to avoid malfunction)
Suggested frequency of replacing the filter net
When the purifier running for 1500 hours, the air purifier will send a siren, and the indicator light of filter replacement will on to remind the users to replace the filter.
At this condition, the purifier can work normally.
Attention
Please turn off and pull out power plug before replacing the filters.
USER MANUAL
7. Fault handling
The following table lists failure possible to appear in dairy use. Please contact company service center or dealer if you cannot find answer from the listed examples.
Status
Machine cannot work fan doesn’t work bad performance possible reason power supply for plug power plug or wire is wrong machine doesn’t turn on motor is wrong
Machine on uneven ground loose or foreign particles come inside motor is loose contact customer service center or dealer plug in and turn on ontact customer service center or dealer move to even and flat ground contact customer service center or dealer filter packing is not removed washable filter is dirty
Filters need to be replaced contact customer service center or dealer please remove packing of every filter wash the dirty filter replace new filter machine inlet or outlet blocked contact customer service center or dealer filter plastic packing is not removed removed packing and then use .
there is no enough space around machine possible solution pull out the plug and pull in again lack of filler or the filler is not properly placed exceed cover please ensure there is 50cm distance between two- side air inlet, the distance to air outlet is not less than 10 cm.
Make sure all the filters are placed in order in accordance with instructions check whether room area is in accordance with the machine effective cover area.
19
20
USER MANUAL
Warranty and service
If you want to know more information or have any questions , please contact customer service center or the dealer.
Product specification may be changed without prior notice .
Waranty 2 years from the purchase day under normal use and surounding conditions.
Order parts or accessories
If you want to change parts or purchase additional parts, please contact your customer service center or the dealer.
Fittings
Fibre filter + HEPA filter net + Activated carbon filter
ISET S.r.l.
Unipersonale
Sede Legale e Uffici
Via Donatori di sangue, 9 - 46024 Moglia (MN)
Tel. e fax +39 (0)376 598963 www.iset-italia.eu [email protected]
Cap. soc. i.v.
Cod. Fisc. e P.IVA Reg. Imprese
REA
Cap. soc. i.v.
€ 10.200,00
02 332 750 369
02 332 750 369
MN 0221098
CERTIFICATE
Certificat - Certificado- Сертификат - Zertifikat - 證書
1) APPLICANT: (who finally puts the product on the market)
Cixi Beilian electrical appliance co., LTD
No.28th,HaitongRoad,GuanhaiweiTown,Cixi,Ningbo,P.R.China
2) CERTIFICATE NO.: ISETC.001020191231
FILE REFERENCE: DL-2019124435S, DL-2019124360E
3) ISET MARK:
4) CAUTION ABOUT CE MARKING (Instruction for the Applicant who puts the product on the EU market):
The label of the CE Marking on the left side should be not less than 5mm height. CE Marking and EC Declaration of Conformity are duties for the manufacturer or its applicant who puts the product on the market. This one is responsible to start the CE marking and certification procedure as required by the legislation in force. Only for the products which are compulsorily included into specific Directives or Regulations will be necessary to appoint a Notified Body.
5) TYPE OF PRODUCT: Air Purifiers
MODEL(S): BKJ-215, BK-01, BK-02, BK-03, BK-05, BK-06, BK-07, BK-08, BKJ-350, BKJ-350A,
BKJ-370, BKJ-306, BKJ-300, BKJ-250F-A01, BKJ-310F-A01, BKJ-300A, BK-02A,
BKJ-215C, BKJ-33, BKJ-306A, BKJ-306B, BKJ-70, BKJ-80A, BKJ-80B, BKJ-215B,
BKJ-50, BKJ-5, BKJ-15, BKJ-15A, BKJ-15B, BKJ-15C, BKJ-03-0725, BKJ-08-0720,
YKX-35-A01, BKJ-250D-A01, BKJ-16A, BJS-30A, BJS-30C, H411, H610, VAP55
6) LIST OF DIRECTIVES / REGULATIONS /STANDARDS (as declared by the manufacturer itself)
Low Voltage Directive 2014/35/EU, Electromagnetic Compatibility 2014/30/EU
EN 55014-1:2017, EN 61000-3-2:2019, EN 61000-3-3:2013+A1:2019, EN 55014-2:2015,
EN 60335-1:2012+A11:2014+A13:2017, EN60335-2-65:2003+A1:2008+A11:2012
7) NOTE: The applicant is aware about the contents and information included in the ModCOM04.06
Regulation for this type of Certificate that is considered totally accepted. The latest revision of the Regulation is available and can be downloaded
8) from the website www.iset-italia.eu. This document is not referred to any evaluation that could be considered as included in the scope of the activities covered by the standard BS EN ISO/IEC 17065:2012 or European Regulation 765/2008.
REMARK: Certificate is issued on voluntary application from the Client and it gives to the applicant the right to use and affix the ISET Mark (at point 3) on their products, even if it doesn’t imply any assessment on the safety and compliance of the product.
ISET declares that the only scope of the assessment is to verify the existence of the declaration
9) issued by the manufacturer or an applicant under its own responsibilities.
DATE OF ISSUE: 31/12/2019
10) SIGNATURE: Li Zhang
EXPIRY DATE: 30/12/2024
(On behalf of the Legal representative)
This document is property of ISET Srl and any kind of reproduction is to be considered strictly forbidden. 81
www.faton-health.com
Advertisement