Advertisement
Advertisement
User Manual
Panel PC
APC-1011
Thank you for purchasing an Autonics product.
This user manual contains information about the product and its proper use, and should be kept in a place where it will be easy to access.
www.autonics.com
.
ii © Copyright Reserved Autonics Co., Ltd.
Preface
Preface
Thank you for purchaseing Autonics product.
Please familiarize yourself with the informaton contained in the Safety Precautions section before using this product.
This user manual contains information about the product and its proper use, and should be kept in a place where it will be easy to access.
© Copyright Reserved Autonics Co., Ltd. iii
User Manual Guide
User Manual Guide
Pleas familiarize yourself with the information in this manual before using the product.
This manual provides detailed information on the product’s features. It does not offer any guarantee concerning matters beyond the scope of this manual.
This manual may not be edited or reproduced in either part or whole without permission.
A user manual is not provided as part of the product package.
Visit our website ( www.autonics.com
) to download a copy.
The manual’s content may vary depending on changes to the product’s software and other unforeseen developments within Autonics, and is subject to change without prior notice.
Upgrade notice is provided throughout the website.
We contrived to describe this manual more easily and correctly. However, if there are any corrections or questions, please notify us these on our website. iv © Copyright Reserved Autonics Co., Ltd.
User Manual Symbols
User Manual Symbols
Symbol Descriptions
Supplementary information for a particular feature.
Failure to follow instructions can result in serious injury or death.
Failure to follow instructions can lead to a minor injury or product damage.
An example of the concerned feature’s use.
※
1 Annotation mark.
© Copyright Reserved Autonics Co., Ltd. v
Safety Considerations
Safety Considerations
Following these safety precautions will ensure the safe and proper use of the product and help prevent accidents, as well as minimizing possible hazards.
Safety precautions are categorized as Warnings and Cautions, as defined below:
Warning
Failure to follow these instructions may result in serious injury or death.
Caution
Failure to follow these instructions may result in personal injury or product damage.
Fail-safe device must be installed when using the unit with machinery that may cause serious injury or substantial economic loss. (e.g. nuclear power control, medical equipment, ships, vehicles, railways, aircraft, combustion apparatus, safety equipment, crime/disaster prevention devices, etc.)
Failure to follow this instruction may result in personal injury, economic loss or fire.
Do not use the unit in the place where flammable/explosive/corrosive gas, high humidity, direct sunlight, radiant heat, vibration, impact, or salinity may be present.
Failure to follow this instruction may result in explosion or fire.
Use the unit within the rated specifications.
Failure to follow this instruction may result in fire or shortening the life cycle of the product.
Do not connect, repair, or inspect the unit while connected to a power source.
Failure to follow this instruction may result in fire.
Check 'Power Wiring' and 'Serial Interface' before wiring.
Failure to follow this instruction may result in fire.
In preparation for product damage, communication error, or malfunction, install external limit switch, emergency stop switch, or other protection circuit.
Failure to follow this instruction may result in personal injury, economic loss or fire.
Since Lithium battery is embedded in the product, do not disassemble or burn the unit.
Failure to follow this instruction may result in fire.
Do not disassemble or modify the unit.
Failure to follow this instruction may result in fire.
Please contact us for battery replacement. vi © Copyright Reserved Autonics Co., Ltd.
Safety Considerations
Use dry cloth to clean the unit, and do not use water or organic solvent.
Failure to follow this instruction may result in fire.
When connecting the power input, use AWG 23 cable or over and tighten the terminal screw with a tightening torque of 0.5 to 0.8N.m.
Failure to follow this instruction may result in fire or malfunction due to contact failure.
Keep metal chip, dust, and wire residue from flowing into the unit.
Failure to follow this instruction may result in fire or product damage.
Do not push over 2 point at the same time.
Failure to follow this instruction may result in malfunction.
The specifications are subject to change and some models may be discontinued without notice.
Be sure to follow cautions written in the instruction manual, user manual and the technical descriptions (catalog, website).
© Copyright Reserved Autonics Co., Ltd. vii
Cautions during Use
Cautions during Use
Follow instructions in ‘Cautions during Use’. Otherwise, it may cause unexpected accidents.
24VDC power supply should be insulated and limited voltage/current or Class 2, SELV power supply device.
Install a power switch or circuit breaker in the easily accessible place for supplying or disconnecting the power.
Operate the product after supplying power to the product, input/output equipment, and load.
If operate product before supplying power, it may result in output error or malfunction.
Keep away from high voltage lines or power lines to prevent inductive noise.
Do not use near the equipment which generates strong magnetic force or high frequency noise.
Make a required space around the unit for radiation of heat, and do not block ventilation openings.
Do not push the touch panel with a hard and sharp object or push the panel with excessive force.
It may result in fire or malfunction.
When skin is smeared with liquid crystal from the broken LCD, rinse with running water for over 15 minutes.
If it gets into the eyes, rinse eyes with running water for over 15 minutes and contact a doctor.
This unit may be used in the following environments.
① Indoors (in the environment condition rated in 'Specifications')
② Altitude max. 2,000m
③ Pollution degree 2
④ Installation category II viii © Copyright Reserved Autonics Co., Ltd.
Table of Contents
Table of Contents
3.1.1 Comprehensive Device Management Program [DAQMaster] ................... 25
3.1.2 Comprehensive Motion Device Management Program [atMotion] ............ 26
3.1.3 Vision Sensor Program [Vision Master] ..................................................... 27
3.1.4 Comprehensive Laser Scanner Management Program [atLidar] .............. 28
3.1.5 Drawing Program for GP/LP Panel [GP Editor] ......................................... 29
3.1.6 Logic Panel Programing Program [SmartStudio] ....................................... 30
© Copyright Reserved Autonics Co., Ltd. ix
Table of Contents
x © Copyright Reserved Autonics Co., Ltd.
1
1.1
1 Product Overview
Product Overview
Features
Panel PC APC-1011 is a Microsoft Windows 10 based HMI(Human-Machine Interface) or
MMI(Man-Machine Interface) device.
As a display panel and a system unit integrated panel PC, the installation restrictions are less,
User who is familiar with Windows 10 is able to use easily without any education.
Familiar to user with the Microsoft Windows 10 OS
Equipped with Quad core processor
Fan less type with low noise, low heat and no need to replacing fan component
Equipped with 10 inch wide IPS TFT LCD of 16,777,216 colors for realizing True color
Possible to be touched with not only hand but also glove, pen tip or etc. with resistive type touch screen
Lesser restrictions on place with display and system all-in-one panel PC
Supporting various types of interface
: HDMI, USB, VGA, Ethernet, Audio, Serial (RS232C/RS485/RS422)
Various methods of installation
: installing on panel, installing with holder (VESA standard 100×100mm)
© Copyright Reserved Autonics Co., Ltd. 11
1 Product Overview
1.2
Specifications
1.2.1
General Specifications
Model
Power supply
Allowable voltage range
Power consumption
Hard disk
System memory
Indicator
Speaker
Watch dog timer
Battery life cycle
APC-1011
24VDC
ᜡ
90 to 110% of power supply
Max. 30W mSATA 64GB SSD
DDR3L 4GB
Power indicator: green LED
Stereo speaker 2W+2W
Watch Dog Timer(1 to 255 sec, software setting)
5 years at 25
℃
Real-time controller
Insulated resistance
Ground
RTC embedded
Min.
100MΩ
(at 500VDC megger)
3rd grounding (max.
100Ω)
Noise immunity ±0.5kV the square wave noise (pulse width:1
㎲
) by the noise simulator
Withstanding voltage 500VAC (50/60Hz) for 1 minute
Vibration
Shock
Environment
Mechanical
0.75mm amplitude at frequency of 10 to 55Hz (for 1 min) in each X, Y, Z direction for 1 hour
Malfunction
0.5 mm amplitude at frequency of 10 to 55Hz (for 1 min)
in each X, Y, Z direction for 1 hour
Mechanical 300m/s
2
(approx. 30G) in each X, Y, Z direction for 3 times
Malfunction 100m/s
2
(approx. 10G) in each X, Y, Z direction for 3 times
Ambient temp.
Ambient humi.
0 to 50 ℃ , storage: -20 to 60 ℃
35 to 85%RH, storage: 35 to 85%RH
Language
※ 1 Korean, English
Protection structure
Accessory
Approval
IP65 (front panel, IEC standard)
Fixing bracket: 8, mold bracket: 1, M3 bolt for mold bracket: 2
ᜢᜣ
Weight
※ 2 Approx. 2kg (approx. 1.6kg)
※ 1: Supported language can be added by downloading language pack.
For more details about language pack, please visit Microsoftwebsite.
※ 2: The weight includes packaging. The weight in parenthesis is for unit only.
※ Environment resistance is rated at no freezing or condesation.
12 © Copyright Reserved Autonics Co., Ltd.
1 Product Overview
1.2.2
Performance Specifications
System performance
CPU Integrated IntelJ3160/1.6GHz Quad core processor, TDP 6W
Operating system
Display peroformance
Windows 10 IoT Enterprise Entry (64bit)
LCD type IPS TFT Color LCD
Touch method Resistive
Resolution
Contrast
Display area
Color
WXGA 1280×800
16:10
216.96×135.6mm
16,777,216 color
LCD view angle
Backlight
Backlight MTBF
Luminance
Interface type
HDMI
USB
VGA
Ethernet
Audio
Serial
Within 85° of top/bottom/left/right
White LED
500,000 hrs (LED Backlighting)
350cd/m2
1
USB 3.0 HOST: 1, USB 2.0 HOST: 2
1
Gigabit Ethernet: 2
1
RS232C/RS422/RS485: 1 (jumper pin setting)
© Copyright Reserved Autonics Co., Ltd. 13
1 Product Overview
1.3
Dimensions
1.3.1
Main Device
(unit: mm)
14 © Copyright Reserved Autonics Co., Ltd.
1.3.2
Bracket
(1) Fixing bracket
(2) Mold bracket
1 Product Overview
1.3.3
Panel Cut-out
※
Panel thickness: Max. 4mm
© Copyright Reserved Autonics Co., Ltd. 15
1 Product Overview
1.4
Unit Description
16
⑦
⑧
⑨
④
⑤
⑥
⑩
⑪
⑫
⑬
⑭
No. Description
① Operation indicator (green LED)
②
③
LCD screen
HDMI
VGA
USB 2.0
Ethernet
USB 3.0
Audio
RS232C/RS485/RS422(jumper pin setting)
Power switch
Power terminal
Fixing bracket mounting slot
Mold bracket mounting hole
VESA hole
© Copyright Reserved Autonics Co., Ltd.
1 Product Overview
1.5
Communication Interface
1.5.1
Serial Interface
(1) Changing serial interface
1st Open the rear case of APC-1011 with a screw driver.
2nd Set the serial interface selecting jumper pin(
① )
with the jumper bar to serial interface to use.
3rd When setting to RS232, connect the D-sub connector to COM2(
②
).
When setting to RS485/RS422, connect the D-sub connector to JP12(
③
).
※
For more details, refer to the below image and table.
No. Name
①
Serial interface setting jumper pin
RS232C(default) RS485 RS422
②
COM2 -
③
JP12 -
(2) D-sub connector by type of serial interface
Port
RS232C
Pin
1
DCD
2
RXD
3
TXD
4
DTR
5
GND
6
DSR
7
RTS
8
CTS
9
RI
Port
RS422
Pin
1
TXD-
2
TXD+
3
RXD-
4
RXD+
5
GND
6
GND
7
Disable
8
Disable
9
Disable
Port
RS485
Pin
1 DATA-
2 DATA+
3 Disable
4 Disable
5 Disable
6 Disable
7 Disable
8 Disable
9 Disable
© Copyright Reserved Autonics Co., Ltd. 17
1 Product Overview
1.5.2
USB 2.0 Interface
USB HOST
4
5
6
7
Pin
1
2
3
8
5V
D1-
D1+
GND
5V
D1-
D1+
GND
1.5.3
USB 3.0 Interface
USB HOST
6
7
8
9
Pin
1
2
3
4
5
5V
D1-
D1+
GND
SSRX1-
SSRX1+
GND
SSTX1-
SSTX1+
18 © Copyright Reserved Autonics Co., Ltd.
1.5.4
Ethernet Interface
RJ-45 for Giga LAN
Crossover – Cable
PC1
Signal Pin no.
Tx+ 1
Tx-
Rx+
2
3
4
5
Rx- 6
7
8
Cable color
White
PC2
Pin no. Signal
Orange 3 Rx+
Orange
White Green
6
1
Rx-
Tx+
Blue
White Blue
4
5
Green
White
Brown
Brown
2
7
8
Tx-
Tx: Transmit Data, Rx: Receive Data
In case of connecting with ethernet router, use direct cable.
Straight(Direct) through – Cable
PC1
Signal Pin no.
Tx+ 1
Tx-
Rx+
2
3
4
5
Rx- 6
7
8
Cable color
White
PC2
Pin no. Signal
Orange 1 Rx+
Orange
White Green
2
3
Rx-
Tx+
Blue
White Blue
4
5
Green
White
Brown
Brown
6
7
8
Tx-
Tx: Transmit Data, Rx: Receive Data
© Copyright Reserved Autonics Co., Ltd.
1 Product Overview
19
1 Product Overview
20 © Copyright Reserved Autonics Co., Ltd.
2 Installation
2
2.1
Installation
Product Installation
(1) Installing on panel
1st Set APC-1011in panel.
2nd Set fixing bracket in slots (3 in top, 2 in bottom, 2 in side).
3rd Tighten fixing brackets with the M4 screw driver with the tightening torque of 0.3 to
0.5N
· m.
4th When additional fixing bracket is in need on the bottom, connect the mold bracket on the rear of the product, before set fixing bracket. Tighten mold bracket with the M3 screw driver with the tightening torque of 0.3 to 0.5N
· m.
※
When using the mold bracket, install it with included bolt(M3×8mm).
If you use bolt out of specification, it my result in product damage.
(2) Installing with holder
You have to purchase 100×100mm holder separately. Autonics does not have dedicated holder.
Fix the purchased holder to the VESA hole on the rear of the product, using M4 Screw driver.
Way to fix holder can be different according to each holder.
© Copyright Reserved Autonics Co., Ltd. 21
2 Installation
2.2
Power Wiring
For power supply, use the power line of which cross section is at least 0.75mm
2
and use the wire of which cross section is at least 1.25mm
2
.
Use round terminal with at least 3mm of internal diameter and less than 6mm of external diameter.
Do not supply power before connecting power line.
Check the power polarity.
Tighten the terminal screw with 0.5 to 0.8 N
.
m torque.
Ground resistance should be less than 100Ω
and ground it separately.
22
Caution for power wiring
Before connecting power line, must check power polarity.
Do not connect the power when the power is supplied.
Observe following allowable voltage change range of power voltage.
Power voltage 24VDC
Allowable voltage change range
21.6 to 26.4VDC
When connecting power, supply power with the power supply which has inner protection circuit. If the power supply which does not have inner protection circuit is used, protection circuits such as fuse must be installed before using this.
© Copyright Reserved Autonics Co., Ltd.
2.2.1
Ground Wiring
2 Installation
Caution for ground wiring
Connect max.
100Ω of ground resistance.
Diameter of cable for ground wiring connection should be over than 2 ㎟ .
As above figure, separate from other device’s ground wire.
© Copyright Reserved Autonics Co., Ltd. 23
2 Installation
24 © Copyright Reserved Autonics Co., Ltd.
3 Software
3 Software
3.1
Software list
3.1.1
Comprehensive Device Management Program [DAQMaster]
DAQMaster is a comprehensive device management program that can be used with Autonics communication supporting products.
DAQMaster provides GUI control for easy and convenient management of parameters and multiple device data monitoring.
© Copyright Reserved Autonics Co., Ltd. 25
3 Software
3.1.2
Comprehensive Motion Device Management Program [atMotion] atMotion is a comprehensive motion device management program that can be used with Autinics motion controller (AiC-D, PMC-2HSP/2HSN, PMC-1HS/2HS, PMC-4B-PCI). atMotion provides GUI control for easy and convenient parameter setting and monitoring data management of multiple devices.
26 © Copyright Reserved Autonics Co., Ltd.
3 Software
3.1.3
Vision Sensor Program [Vision Master]
Vision Master is the vision sensor program that is connected with VG Series, Autonics vision sensor, to utilize it.
Vision Master provides graphic user interface to make setting parameter and managing monitoring data of vision sensor easy.
It is connected with vision sensor through Ethernet (TCP/IP) and exchange data with vision sensor.
© Copyright Reserved Autonics Co., Ltd. 27
3 Software
3.1.4
Comprehensive Laser Scanner Management Program [atLidar] atLidar is laser scanner management program that can be used with laser scanner LSE-4A5R2. atLidar is the management program for laser scanner installation, parameter settings, status information and monitoring data, etc.
This program communicates with the laser scanner via Ethernet communication.
28 © Copyright Reserved Autonics Co., Ltd.
3 Software
3.1.5
Drawing Program for GP/LP Panel [GP Editor]
All data of GP/LP user screen is edited in exclusive software GP Editor.
After editing screen data including forms, layout, properties of tags and etc., download data to
GP/LP, it starts to monitor by the screen data of GP/LP.
© Copyright Reserved Autonics Co., Ltd. 29
3 Software
3.1.6
Logic Panel Programing Program [SmartStudio]
SmartStudio is the exculsive software to write program and debug for LP series.
3.2
Software Installation
Vision Master is intalled as a factory default.
To use other program, please follow the instruction below.
(1) Installation via PC
1st Download program to install from Autonics website ( www.autonics.com
).
2nd Save the downloaded installation file in a USB driver and plug the USB driver to USB port of APC-1011 to move the installation file.
3rd Touch the installation file in APC-1011 to install the program.
(2) Direct installation
1st Plug LAN cable to Ethernet port of APC-1011 to connect to Internet.
2nd Access to Autonics website ( www.autonics.com
) in APC-1011 to download program.
3rd Touch the downloaded installation file in APC-1011 to install the program.
30 © Copyright Reserved Autonics Co., Ltd.
4 Operating Panel PC
4
4.1
4.2
Operating Panel PC
Describes the operation procedure from when the power is supplied on APC-1011 to when the software is executed.
Power Supplying Checklist
Please check the following list below, before supplying the power on APC-1011.
No Checklist
1
Installation status
2
3
4
Ground
Power cable
Power
Descriptions
Check all the mounting brackets are properly installed.
Check the mounting brackets are tightened with appropriate torque.
Check the ground is separated from other devices.
Check the 3rd grounding.
Check the wiring connections for polarity.
Check the terminal screw tightness.
Check the power supply voltage.
Check the power is installed separately from other devices.
Operation Procedure
Make sure that the connectors are well connected to each interface.
Supply the power and turn on APC-1011.
Wait untill the boot finishes and the screen is displayed.
Whe the Windows is ready to use, run the program.
© Copyright Reserved Autonics Co., Ltd. 31
4 Operating Panel PC
32 © Copyright Reserved Autonics Co., Ltd.
5
5.1
Settings
Touchside Settings
5 Settings
Touchside program is a program for hardware device setting.
Touchsid’s setting menu is as blow.
Tab
General
Setting
Tools
Display
Menu
Installed
Touchscreen
Controllers
-
Descriptions
Displays the recognized touchscreen controller on the system.
Monitor Mapping -
Beep
Linearization
Style
Double Click
Time/Area
-
-
-
In case of using multiple monitors, maps the touchscreen to the monitors.
Set the touch buzzer.
When performing linear calibration on the ‘Tools’ tab, set the number of adjust points.
Set the double click time/area.
Touch Mode
Set the touch mode.
Normal Mode
Support click and drag function
Support drag mode at click
Click on
Touch
Click on
Release
Recognize as click when touching
(drag function is not supported)
Recognize after touch is released
(drag function is not supported)
-
Click on
Touch-Cursor
Fixed
Click on
Release-
Cursor Fixed
Moving cursor after click recognition with click on-touch method (fixed)
Moving cursor after click recognition with click on-release method (fixed)
Background
Mode
Support click and drag function
Support drag mode after click 1 sec
Option Set the touch-related detail functions.
Linearization
Curve
4 Points
Calibration
Clear and
Calibrate
Linearization
Draw Test
-
-
-
-
-
Check the current calibration data.
Run 4-point alignment to match the screen.
Run 4-point alignment after clearing the calibration data.
Run the precision calibration to improve accuracy.
Run the draw test to check the calibration status.
Display -
Operation Mode -
Other
Check the current display status.
Set the touch functioning area on the screen.
Other Set the touch functioning area on the screen in detail.
© Copyright Reserved Autonics Co., Ltd. 33
34
5 Settings
Tab
Edge
Compensation
Hardware
About
Menu
Edge
Parameters
Edge
Compensation
Hardware
Informations
Hardware
Setting
Informations
-
-
-
-
-
Descriptions
Corrects the touch area for corner parts in detail.
Corrects the touch area for edge parts in detail.
Check hardware device informations.
Set the parameter value of the touch controller firmware in detail.
Check Touchside software informations.
5.1.1
Touch Settings
Through the touch points calibration, touching the exact point is possible.
1st Run the ‘Touchside’ program on the desktop.
2nd Set the ‘Linearization Style’ on ‘Setting’ tap.
3rd Click the ‘Linearization’ on ‘Tools’ tap.
When the caliblation screen shows up, touch and hold the 9 touch points in sequence untill OK appears to correct the touch points.
© Copyright Reserved Autonics Co., Ltd.
5 Settings
5.1.2
Draw Test
Draw a line to verify that the touch point matches the actual action point.
1st Run the ‘Touchside’ program on the desktop.
2nd Click ‘Draw Test’ on ‘Tools’ tap.
3rd When the test screen shows up, draw lines on the screen to make sure the touch point matches the actual action point.
Click ‘Clear’ to erase all drawn lines, and click ‘Quit’ to exit the drawing test.
5.2
Windows Settings
Please refer to Microsoft for corresponding contents such as changing system languange, system setting, account management and etc.
© Copyright Reserved Autonics Co., Ltd. 35
5 Settings
36 © Copyright Reserved Autonics Co., Ltd.
6 Maintenance
6
6.1
6.2
Maintenance
Routine Maintenance
The inspections are required for every day/week.
Checklist Details
Temperature
Criteria
0 to 50
℃
Environment Humidity 35 to 85% RH
APC-1011’s attached status
Comm. cable connection status
Vibration
Check the bracket screw loosening
Check the cable connecting screw loosening
No vibration
Attached without shaking
Cable connection must be securely tightened
Regular Maintenance
The inspections are required for monthly.
Checklist
Power supply voltage
Leakage and dustproof
Flammable gas
Details
Measure the power supply voltage
Leakage and dustproof condition
Flammable gas exposure
Criteria
Within the allowable voltage range
No leakage and dusts must not to be accumulated
Not to be exposed to flammable gas
Solution
Control ambient temperature
Control ambient humidity
Establish anti-vibration measures
Tighten the screw
Tighten the screw
Use genuine cable
Solution
Replace the power supply
Establish leakage and dustproof measures
Establish flammable gas measures
Caution for regular maintenance
Make sure to use a standard measuring devices, when inspecting the power supply voltage.
When the defect is found, please record and notify us the defect in detail.
When replacing the product, make sure to turn the power off.
When removing dust or dirt, use a dry cloth that does not contain water or detergent.
© Copyright Reserved Autonics Co., Ltd. 37
* Dimensions or specifications on this manual are subject to change and some models may be discontinued without notice.
MTO-APC1011U1-V1.1-1905US
Advertisement