KUSAM-MECO KM 033 AC True RMS Digital Clampmeter Manual
The Kusam-meco KM 033 is a versatile digital clamp meter designed for electrical measurements in various applications. It features True RMS sensing, allowing accurate measurements of AC voltage and current, even in the presence of distorted waveforms. With a maximum AC current measurement range of 600A and AC voltage range of 660V, it is suitable for residential, commercial, and industrial electrical work. Additionally, it can measure DC voltage up to 600V, DC current up to 600mA, resistance, capacitance, frequency, temperature, and perform continuity and diode tests.
Advertisement
Advertisement
LIST OF PRODUCTS
Digital Multimeter Digital AC & AC/DC Clampmeter
AC Clamp Adaptor AC/DC Current Adaptor
Thermo Anemometer Thermo Hygrometer
Distance Meter Digital Lux Meter
Network Cable Tester Power Factor Regulator
Earth Resistance Tester Digital Panel Meters
DC Power Supplies High Voltage Detector
Calibrators Gas Analysers
Frequency Counter Function Generator
Phasing Sticks Battery Tester
Waterproof Pen Testers Solar Power Meter
EMF Detector
Wood, Paper & Grain Moisture Meter
Transistorised Electronic Analog & Digital Insulation
Resistance Testers(upto 10 KV)
Digital Sound Level Meter & Sound Level Calibrator
Digital contact & Non-contact Type Tachometer
Digital Non-contact (infrared) Thermometer
Maximum Demand Controller/Digital Power Meter
Digital Hand Held Temperature Indicators
®
G 17, Bharat Industrial Estate, T. J. Road,
Sewree (W), Mumbai - 400 015. INDIA.
Sales Direct :
(022) 24156638
Tel. :
(022) 24124540, 24181649.
Fax :
(022) 24149659
Email :
[email protected]
Website :
www.kusamelectrical.com
www.kusam-meco.co.in
AN ISO 9001:2015 COMPANY
AC TRUE RMS
DIGITAL CLAMPMETER WITH
EF-DETECTION, AMPTIP FUNCTION
FOR LOW CURRENT
MEASUREMENT
MODEL - KM 033
OPERATION MANUAL
®
AC TRMS
DIGITAL CLAMPMETER
MODEL - KM 033
®
I. SAFETY :
The meter meets UL / IEC / EN61010-1 Ed. 3.0, CAN / CSA C22.2
No. 61010-1Ed.3.0, UL/IEC/EN61010-2-032 Ed.3.0, UL/IEC/
EN61010-2-033 Ed. 1.0 to measurement CAT-III 600V and
CAT-IV 300V, AC & DC.
The accompanied test probe assembly meets UL/IEC/EN61010-
031 Ed. 2.0 to the same meter ratings or better. IEC 61010-031 requires exposed conductive test probe tips to be ≤ 4mm for CAT
III & CAT IV ratings. Refer to the category markings on your probe assemblies as well as on the add-on accessories (like detachable
Caps or Alligator Clips), if any, for applicable rating changes.
TERMS IN THIS MANUAL :
WARNING Identifies conditions and actions that could result in serious injury or even death to the user.
CAUTION Identifies conditions and actions that could cause damage or malfunction in the instrument.
WARNING :
This manual contains information and warnings that must be followed for operating the meter safely and maintaining the meter in a safe operating condition. If the meter is used in a manner not specified by the manufacturer, the protection provided by the meter may be impaired.
Observe proper safety precautions when working with voltages above 30 Vrms, 42.4 Vpeak or 60VDC. These voltage levels pose a potential shock hazard to the user. Do not expose this product to rain or moisture. The meter is intended only for indoor use.
01
®
Keep your hands/fingers behind the hand/finger barriers (of the meter and the test leads where applicable) that indicate the limits of safe access of the hand-held part during measurement. Inspect test leads, connectors and probes for damaged insulation or exposed metal periodically. If any defects are found, replace them immediately. Only use the test lead provided with the equipment or a
UL Listed Probe Assembly rated CAT III 600V or better.
INTERNATIONAL ELECTRICAL SYMBOLS :
3~
Caution ! Refer to the explanation in this Manual.
Caution ! Risk of electric shock.
Earth (Ground)
Double Insulation or Reinforced insulation
Fuse
AC--Alternating Current
DC--Direct Current
Application around and removal from hazardous live conductors is permitted.
Three-phase Alternating Current
BRIEF INFORMATION ON MEASUREMENT CATEGORIES
MEASUREMENT CATEGORY IV is applicable to test & measuring circuits connected at the source of the building’s low-voltage MAINS installation. Examples are measurements on devices installed before the main fuse or circuit breaker in the building installation.
02
®
MEASUREMENT CATEGORY III is applicable to test & measuring circuits connected to the distribution part of the building’s low-voltage
MAINS installation. Examples are measurements on distribution boards (including secondary meters), circuit-breakers, Cables, bus-bars, junction boxes, switches, socket-outlets, stationary motors in the fixed installation, and equipment for industrial use.
MEASUREMENT CATEGORY II is applicable to test & measuring circuits connected directly to utilization point (socket outlets & similar points) of the low-voltage MAINS installation. Examples are measurements on MAINS CIRCUITS of household appliances, portable tools and similar equipment.
II. CENELEC Directives :
The instruments conform to CENELEC Low-voltage directive 2014/
35/EU, Electromagnetic compatibility directive 2014/30/EU and
RoHS directive 2015/863/EU.
III SPECIAL FEATURES :
TM
AmpTip low-current range calibrated at Jaw-tip for slim-conditions
for accurate readings
MAX / MIN Recording mode.
MAX / MIN Crest (Peak-Hold) mode.
Relative-zero mode.
Display Hold
EF-Detection (NCV).
Back-lighted easy-to-read LCD display
Fully Autoranging
TM
BeepLit Feature.
03
®
GENERAL SPECIFICATIONS :
Sensing : True RMS
Jaws Opening size : 26mm Max.
Display : 3-5/6 digits 6000 counts
Update Rate : 5 per second nominal
Polarity : Automatic
Operating Temperature : 0ºC to 40ºC
Relative Humidity : Maximum relative humidity 80% for temperature up to
31ºC decreasing inearly to 50% relative humidity at 40ºC.
Altitude : Operating below 2000m
Storage Temperature : -20°C ~ 60°C, <80% R.H. (with battery removed)
o
Temperature Coefficient : Nominal 0.1 x (specified accuracy) / C @ o o o
Power Supply : Standard 1.5V AAA Size Battery X 2
Power Consumption : typical 14mA for current function.
Low Battery : Below approx. 2.85V for Capacitance & Hz
Below approx. 2.5V for other functions
APO timing : Idle for 32 minutes
APO Consumption : typical 5 A
Dimension : 188(L) x 66(W) x 32(H)mm
Weight : approx 202 gms.
04
®
SAFETY :
Safety : Certified per IEC/UL/CSA_C22.2_# / EN standards. 61010-1 Ed.3.0,
61010-2-032 Ed. 3.0,61010-2 033 Ed. 1.0 & 61010-031 Ed. 2.0 to
Measurement Categories CAT III 600V AND CAT IV 300V AC & DC.
Overload Protection :
Current via jaws : 600A DC / AC rms at <400Hz.
Voltage via terminal: 660V DC / 920VAC rms.
Other functions via terminals : 600V DC / VAC rms
Pollution Degree : 2
E.M.C. : Meets EN61326-1:2013
DCA and ACA Functions, in an RF field of 1V/m :
Total Accuracy = Specified Accuracy + 40 digits at around 87MHz
DC A & Ohm Functions, in an RF field of 1V/m :
Total Accuracy = Specified Accuracy + 25 digits
Other Functions, in an RF field of 3V/m :
Total Accuracy = Specified Accuracy + 20 digits
Transient Protection : 6.0kV (1.2/50 s surge)
Rugged Fire retarded housing.
LVD EN61010-1/61010-2-032/61010-2-033 to CAT III 600V & CAT IV 300V
Accessories : Test leads set, Users Manual, Carrying case.
05
®
ELECTRICAL SPECIFICATIONS :
Accuracy is ± (% of reading digits + number of digits) or otherwise o o specified, at 23 C ± 5 C. Maximum Crest Factor <2 :1 at full scale &
<4:1 at half scale or otherwise specified, and with frequency spectrum not exceeding the specified frequency bandwidth for non-sinusoidal waveforms.
REGULAR AC CLAMP-ON CURRENT
Range Resolution Accuracy
1) 2)
50Hz ~ 100Hz
600.0 A 0.1 A ±(1.5%rdg + 5dgts)
100Hz ~ 400Hz
600.0 A 0.1 A ±(2.0%rdg + 5dgts)
1)
Induced error from adjacent current-carrying conductor : < 0.6A/A
2) Specified accuracy is for measurements made at the jaw center.
When the conductor is not positioned at the jaw center, add 2% to
specified accuracy for position errors.
Accuracy
1)
Range Resolution
50Hz ~ 60Hz
60.00 A 0.01 A ±(1.0%rdg + 5dgts)
1)
Induced error from adjacent current-carrying conductor : < 0.06A/A
Range
200.0 A
2000 A
Burden Voltage : 3.5mV/ A
Resolution
0.1 A
1 A
Accuracy
±(1.0%rdg + 5dgts)
06
®
DC VOLTAGE
Range Resolution
600.0 V 0.1 V
Input Impedance : 10M , 100pF nominal
Accuracy
±(1.0%rdg + 5dgts)
AC VOLTAGE (with Digital Low-Pass Filter)
Range Resolution Accuracy
50Hz ~ 60Hz
±(1.5%rdg + 5dgts) 600.0 V 0.1 V
Input Impedance : 10M , 100pF nominal
RESISTANCE
Range Resolution
0.1 600.0
60.00K
10
100 600.0K
6000K 1 k
Open Circuit Voltage : 1.0VDC typical
Accuracy
±(1.0%rdg + 5dgts)
TM
BeepLit DIODE TESTER
Range Resolution
3.000 V 1 mV
Test Current : 0.3mA typically
Open Circuit Voltage : < 3.5VDC typically
Short Beep Alert Threshold : Drop across 0.850V
TM
BeepLit ON Threshold : <0.100V
Audible indication : Beep Sound
Visible Indication : LCD Backlight.
07
Accuracy
1)
±(1.5%rdg + 5dgts)
®
CAPACITANCE
Range Resolution
200.0 F 0.1 F
2500 F 1 F
1)
Accuracies with film capacitor or better
Accuracy 1)
±(2.0%rdg + 4dgts)
HZ LINE LEVEL FREQUENCY
Function
(Sine RMS)
Range
600 V 50 V 5.00Hz~999.9Hz
Accuracy : ±(1%rdg + 5dgts)
1)
DC-bias, if any, not more than 50% of Sine RMS
TEMPERATURE
Range Accuracy 1)2)
-40.0ºC ~ 99.9ºC
100.0ºC ~ 400ºC
-40.0ºF ~ 211.8ºF
± (1.0% + 1.0ºC)
± (1.0% + 1ºC)
± (1.0% + 2.0ºF)
212ºF ~ 752ºF ± (1.0% + 2ºF)
1) Accuracies assume meter interior has the same temperature of the
ambient (isothermal stage) for a correct junction voltage compensation.
Allow the meter & the type-K probe set to reach isothermal stage for a
significant change of ambient temperature. It can take up to an hour
for changes >5°C.
2) Type-K thermocouple range & accuracy not included.
CREST (Peak-Hold)
Applicability
Accuracy
Voltage & Non-invasion Current functions
Add ± 250 digits to specified accuracy for changes > 5ms in duration.
08
®
Continuity Threshold Between 30 & 480
Continuity ON
Response Time
Audible Indication
15ms approx.
Beep sound
Visible Indication LCD Backlight
NON-CONTACT EF-DETECTION
Bar-Graph
Indication
-
EF-H
(Hi Sensitivity)
EF-L
(Lo Sensitivity)
Typical Voltage (Tolerance)
10V (2V~20V) 40V (10V~70V)
- 20V (4V~40V) 80V (20V~140V)
- - 40V (8V~70V) 160V (40V~280V)
- - - 80V (16V~140V) 320V (80V~560V)
- - - - 160V (>40V) 500V (>160V)
Indication : Bar-graph segments & audible beep tones proportional to the field
strength.
Detection Frequency : 50/60Hz
Detection Antenna : Inside the top side of the stationary jaw
Probe-Contact EF-Detection : For more precise indication of live wires, such as distinguishing between live and ground connections, use one single probe to test via terminal COM for direct Metal Probe-contact EF-Detection to achieve the most distinctive indication.
09
®
10
9
VI. PRODUCT DESCRIPTION :
This manual uses only representative model(s) for illustrations.
Please refer specification details for function availability to this model.
8
3
7
11
+
MAX 600A
600V CAT III
300V CAT IV
Hz
V
OFF
V
SELECT
A
6.0.3.3
CREST
REC
A
EF
COM
300V CAT IV
600V CAT III
+
+
1
1. Antenna area for Non-Contact EF-
Detection
3
4
5
2
2. Jaw center indicator
at where best current accuracy is
specified.
3. Push-buttons for special functions & features.
4. Rotary Selector to turn the power
ON/OFF and Select a function.
5. 3-5/6 digits 6000 counts numeric
LCD display.
6. Input Jack for all functions EXCEPT non-invasive current functions.
7. Common (Ground reference) Input
Jack for all functions EXCEPT the
Clamp-on current and Non-Contact
EF-Detection functions.
8. Jaw trigger for opening the clamp jaw.
9. Hand/Finger Barrier to indicate the limits of safe access of the meter.
10. Clamp Jaw for Clamp-on current magnetic field pick up.
6
11. Additional center indicator for
TM
AmpTip Low-current function, at
TM where best AmpTip current accuracy is specified.
10
®
VII. OPERATION :
WARNING : Before and after hazardous voltage measurements, test the voltage function on a known source such as line voltage to determine proper meter functioning.
ACV, Line-level Hz :
Inputs, are made through the test lead terminals COM/+ . Defaults at ACV Function. Press SELECT button momentarily to select
Line-level Hz function.
Note : ACV and Line-level Hz function are equipped with low-pass filter, & are capable of dealing with VFD (Variable Frequency Drive) signals. It also improves ACV reading stability in noisy electrical environments.
DCV
Inputs are made through the test lead terminals COM/+.
Hz
V
600V CAT III
300V CAT IV
CREST
REC
A
EF
A
Hz
V
OFF
V
SELECT
~ 120.8
V
COM
300V CAT IV
600V CAT III
+
SELECT
600V CAT III
300V CAT IV
CREST
REC
Hz
V
OFF
V
SELECT
A
EF
A
1 60.01
Hz
COM
300V CAT IV
600V CAT III
+
V
600V CAT III
300V CAT IV
CREST
REC
A
EF
A
Hz
V
OFF
V
SELECT
~ 009.7
V
COM
300V CAT IV
600V CAT III
+
11
®
Clamp-on Current Measurements :
Application & Removal of the Jaws
Press the jaw trigger & clamp the jaws around conductor(s) of only one single pole of a circuit for load current measurements. Make sure the jaws are completely closed, or else it will introduce measurement errors. Enclosing conductors of more than one pole of a circuit may result in differential current (like identifying leakage current) measurements. Align the conductors to the Jaws center indicators
(Regular or AmpTipTM indicators where applicable) as much as possible to get the best measuring accuracy. For removal, press the jaw trigger and remove the jaws from the conductors.
Adjacent current-carrying devices such as transformers, motors and conductor wires may affect measurement accuracy. Keep the jaws away from them as much as possible to minimize influence.
WARNING :
This Clamp-on meter series is designed to directly apply around or remove from uninsulated hazardous live conductors. But still, individual protective equipment must be used if hazardous live parts in the installation where measurement is to be carried out could be accessible. Do not use the meter to measure currents above the rated frequency (400Hz). Circulating currents may cause the magnetic circuits of the Jaws reach a hazardous temperature.
12
®
TM
Clamp-on AmpTip ACA
+
Hz
V
V
OFF
SELECT
MAX 600A
300V CAT IV
CREST
REC
A
EF
A
COM
~ 28.0
1
A
+
300V CAT IV
600V CAT III
+
Input is made via the clamp jaws where best accuracy is specified near the jaw
TIP-CENTER area for low-current measurements of thin conductors.
Defaults at ACA function.
Press SELECT button momentarily to select DCA function.
Clamp-on Regular ACA
+
MAX 600A
300V CAT IV
CREST
REC
A
A
EF
Hz
V
OFF
V
SELECT
~ 32 18
A
COM
300V CAT IV
600V CAT III
+
+
Input is made via the clamp jaws where best accuracy is specified at the jaw
CENTER area. Defaults at ACA function.
Press SELECT button momentarily to select DCA function.
13
®
TM TM
Resistance, BeepLit Continuity & BeepLit Diode :
Inputs are made through the test lead terminals COM/+ .
Defaults at Resistance . Press SELECT button momentarily to select the subject functions in sequence.
TM
BeepLit Continuity :
This function is having improved convenience for checking wiring connections and operation of switches. Resistance threshold is being used. A continuous beep tone together with flashing display backlight indicate a complete wire. Such audible and visible indications improve continuity readabilities in noisy working environments.
TM
BeepLit Diode :
Reading indication : Forward voltage drop (forward baised) for a good silicon diode is between 0.400V to 0.900V. A higher reading indicates a leaky diode (defective). A zero reading indicates a shorted diode
(defective). An over-range display indicates an open diode (defective)
Reverse the test leads connections (reverse biased) across the diode.
The digital display shows over-range if the diode is good. Any other readings indicate the diode is resistive or shorted (defective).
TM
Beep-Alert & BeepLit Indication :
When the display reading drops across 0.850V, the meter alerts a short beep to signal a reasonable forward voltage drop of common diodes. However, if the reading further drops below 0.100V, the meter gives a continuous beep tone together with flashing display backlight to indicate a shorted diode or a complete wire. it is similar to
TM TM that of BeepLit Continuity function but BeepLit Diode , instead, is based on voltage threshold to indicate a complete wire.
14
®
CAUTION :
TM TM
Using Resistance, BeepLit Continuity or BeepLit Diode function in a live circuit will produce false results and may damage the meter. In many cases, the suspected components must be disconnected from the circuit to obtain an accurate measurement reading.
+ + + + +
MAX 600A
600V CAT III
300V CAT IV
CREST
REC
A
EF
A
Hz
V
OFF
V
SELECT
320.8
k
COM
300V CAT IV
600V CAT III
+
SELECT
MAX 600A
600V CAT III
300V CAT IV
CREST
REC
A
EF
A
Hz
V
OFF
V
SELECT
1 00 12
COM
300V CAT IV
600V CAT III
+
SELECT
MAX 600A
600V CAT III
300V CAT IV
CREST
REC
A
EF
A
Hz
V
OFF
V
SELECT
1
V
COM
300V CAT IV
600V CAT III
+
+ + +
MAX 600A
600V CAT III
300V CAT IV
CREST
REC
A
EF
A
Hz
V
OFF
V
SELECT
0.602
V
COM
300V CAT IV
600V CAT III
+
V
EF-Detection of Electric Field
Defaults at high sensitivity EF-H.
The meter displays “EF-H” when it is ready. If it is too sensitive for your applications, press SELECT button momentarily to select lower sensitivity “EF-L”.
The detected Electric
Field strength is indicated as a series of bar-graph segments on the display plus variable beep tones.
Non-Contact EF-Detection (NCV) : An antenna is located along the top-right end of the stationary clamp jaw, which detects electric field that surrounds energized conductors. It is ideal for tracing live wiring connections, locating wiring breakage and to distinguish between live or earth connections.
15
®
Probe-Contact EF-Detection : For more precise indication of live wires, such as distinguishing between Live and Ground connections, use one single probe to test via terminal COM for direct metal
Probe-Contact EF-Detection to achieve the most distinctive indication.
+ + + + + + +
MAX 600A
600V CAT III
300V CAT IV
CREST
REC
V
OFF
SELECT
A
EF
A
EF
EF-H
COM
300V CAT IV
600V CAT III
+
MAX 600A
600V CAT III
300V CAT IV
CREST
REC
Hz
V
OFF
V
SELECT
A
EF
A
COM
300V CAT IV
600V CAT III
+
SELECT
MAX 600A
600V CAT III
300V CAT IV
CREST
REC
Hz
V
OFF
V
SELECT
A
EF
A
EF
1
MAX 600A
600V CAT III
300V CAT IV
CREST
REC
Hz
V
OFF
V
SELECT
A
EF
A
COM
300V CAT IV
600V CAT III
+
COM
300V CAT IV
600V CAT III
+
+
+
MAX 600A
600V CAT III
300V CAT IV
CREST
REC
A
EF
A
Hz
V
OFF
V
SELECT
+ +
MAX 600A
600V CAT III
300V CAT IV
CREST
REC
A
EF
A
Hz
V
OFF
V
SELECT
+
COM
300V CAT IV
600V CAT III
+
COM
300V CAT IV
600V CAT III
+
Live Ground
16
®
DC
A Current function :
Inputs are made through the test lead terminals COM/+ . Defaults at
EF-Detection function. Press SELECT button momentarily two times to select DC A function.
Application Notes :
SELECT
1
MAX 600A
600V CAT III
300V CAT IV
Hz
V
OFF
V
SELECT
COM
A
128.1
+
300V CAT IV
600V CAT III
CREST
REC
EF
A
A
The DC A function designed especially for
HVAC/R flame sensor applications. The
0.1
A resolution is useful for identifying the minute current changes in flame detector applications. Flame signal current check should indicate steady flame signal of at least 2 A for a rectification type, or 1.5
A for an ultraviolet type (8 A for self checking systems). If a flame signal current with inadequate strength or fluctuation beyond 10%, check the following to avoid the risk of unwanted flame relay dropout :
For gas or oil flames (Minipeeper) :
Dirty viewing windows
For oil flames (Photocell) :
Detector location & wiring
Smoky flame or poorly adjusted air shutter
Faulty Photocell
Temperature over 165ºF
(74ºC) at photocell
For gas flames (Flame Rod) :
Ignition interference (A flame signal current difference with the ignition both on and off greater than 0.5
A indicates the presence of ignition interference).
Insufficient ground (must be at least 4 times the detector area).
Flame lifting off burner head (ground), or not continuously in contact with the flame rod.
Temperature in excess of 600ºF (316ºC) at the flame electrode insulator causing short to ground.
17
®
Capacitance & Temperature :
Inputs are made through the test lead terminals COM/+ . Defaults at
Capacitance . Press SELECT button momentarily to select °C
(Celsius) and °F (Fahrenheit) in sequence (°F selection can be left out as factory calibration default for countries that only accept metric units).
MAX 600A
600V CAT III
300V CAT IV
CREST
REC
A
EF
A
Hz
V
OFF
V
SELECT
F
18.35
COM
300V CAT IV
600V CAT III
+
SELECT
Hz
V
OFF
V
SELECT
MAX 600A
600V CAT III
300V CAT IV
CREST
REC
A
EF
A
1 25.8C
COM
+
–
300V CAT IV
600V CAT III
+
SELECT
Hz
V
OFF
V
SELECT
MAX 600A
600V CAT III
300V CAT IV
CREST
REC
A
EF
A
1 78.4F
COM
+
–
300V CAT IV
600V CAT III
+
– +
+ +
+ +
Note :
Be sure to insert the banana plug type-K temperature bead probe
Bkp60 with correct + polarities. Banana pins to type-K socket adapter Bkb32 (Optional purchase) can be used to accept other type-K probes using standard miniature plug.
Temperature accuracies assume meter interior has the same temperature of the ambient (isothermal stage) for a correct junction voltage compensation. Allow the meter and the type-K probe set to reach isothermal stage for a significant change of ambient temperature.
It can take up to an hour for changes > 5°C.
18
®
CAUTION :
Discharge capacitors before making capacitance measurements. Large value capacitors should be discharged through an appropriate resistance load. Using capacitance function in a live circuit will produce false results and may damage the meter. In many cases the suspected components must be disconnected from the circuit to obtain accurate measurement readings.
HOLD :
Press the HOLD button momentarily to toggle the hold feature.
RECORD MODE :
Press REC button momentarily to activate MAX/MIN recording mode.
LCD MAX & MIN turn on. The meter beeps when new MAX
(maximum) or MIN (minimum) reading is updated. Press the button momentarily to read the MAX, MIN and MAXMIN (active measurement) readings in sequence. Press the button for 1 second or more to exit this mode. Auto-Power-Off is disabled automatically in this mode.
5ms CREST MODE :
Press CREST button for one second or more to activate CREST mode
(instantaneous PEAK-HOLD) to capture current or voltage peak values in duration as short as 5ms. LCD & MAX turn on. The meter beeps when new MAX (maximum) or MIN (minimum) reading is updated.
Press the button momentarily to toggle the MAX and C MIN readings.
Press the button for 1 second or more to exit this mode. Auto-power-
Off is disabled automatically in this mode.
LCD Backlight & Auto-Backlight-Off (ABO) :
Press the SELECT button for 1 second or more to toggle the LCD backlight. The ABO mode turn the LCD backlight off automatically after idling for 10 minutes to extend battery life. See Power-on
Options section for disabling ABO.
19
®
Intelligent Auto-Power-Off (APO) :
The Auto-Power-Off (APO) mode turns the meter off automatically to extend battery life after approximately 32 minutes of no specified activities, where applicable, below :
1. Rotary switch or push button operations.
2. Significant measuring readings of above 8.5% of ranges.
3. Non-over-range readings for Resistance, Continuity or Diode function.
4. Non-zero readings for Hz function.
In other words, the meter will intelligently reset the APO mode when it is under normal measurements. To wake up the meter from APO, press the SELECT button momentarily and release, or turn the rotary switch OFF and then back on. Always turn the rotary switch to the
OFF position when the meter is not in use.
POWER-ON OPTION :
Disabling APO & ABO
Press & hold the SELECT button while powering on the meter can disable both APO & ABO features temporarily during the power on session. The LCD will display “ dAPO ” to confirm selection before the SELECT button is released.
Shortening APO idling time for inspection
Press & hold the HOLD button while powering on the meter can shorten the APO idling time to 5 seconds temporarily during the power on session. It is designed mainly for production inspection.
Showing all LCD segments for inspection
Press & hold the REC button while powering on the meter can hold
& show all LCD segments before the button is released. It is designed mainly for production inspection.
20
®
V. MAINTENANCE :
WARNING :
To avoid electrical shock, disconnect the meter from any circuit, remove the test leads from the input jacks and turn OFF the meter before opening the case. Do not operate with open case.
Trouble Shooting :
If the instrument fails to operate, check batteries and test leads etc., and replace as necessary. Double check operating procedure as described in this manual.
Cleaning and Storage :
Periodically wipe the meter & the test probe assembly with a damp cloth and mild detergent. Do not use abrasives or solvents. Allow to dry completely before operating. If the meter is not to be used for periods of longer than 60 days, remove the batteries and store them separately.
Battery replacement :
The meter uses standard 1.5V AAA Size (IEC R03) battery X 2.
Loosen the 2 captive screws from the battery cover case. Lift the battery cover case. Replace the batteries. Replace battery cover case. Re-fasten the screws.
21
®
MUMBAI
TEST CERTIFICATE
AC TRMS DIGITAL CLAMPMETER
This Test Certificate warrantees that the product has been inspected and tested in accordance with the published specifications.
The instrument has been calibrated by using equipment which has already been calibrated to standards traceable to national standards.
SERIAL NO. ___________
DATE: ___________
ISO 9001
REGISTERED
22
QC
KUSAM-MECO
PASS
®
WARRANTY
Each “KUSAM-MECO” product is warranted to be free from defects in material and workmanship under normal use & service. The warranty period is one year (12 months) and begins from the date of despatch of goods. In case any defect occurs in functioning of the instrument, under proper use, within the warranty period, the same will be rectified by us free of charges, provided the to and fro freight charges are borne by you.
This warranty extends only to the original buyer or end-user customer of a “KUSAM-MECO” authorized dealer.
This warranty does not apply for damaged Ic’s, fuses, burnt PCB's, disposable batteries, carrying case, test leads, or to any product which in “KUSAM-MECO’s” opinion, has been misused, altered, neglected, contaminated or damaged by accident or abnormal conditions of operation or handling.
“KUSAM-MECO” authorized dealer shall extend this warranty on new and unused products to end-user customers only but have no authority to extend a greater or different warranty on behalf of “KUSAM-MECO”.
“KUSAM-MECO’s” warranty obligation is limited, at option, free of charge repair, or replacement of a defective product which is returned to a “KUSAM-MECO” authorized service center within the warranty period.
THIS WARRANTY IS BUYER’S SOLE AND EXCLUSIVE REMEDY
AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR
IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED
WARRANTY OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE. “KUSAM-MECO” SHALL NOT BE LIABLE
F O R A N Y S P E C I A L , I N D I R E C T, I N C I D E N TA L O R
CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF
DATA, ARISING FROM ANY CAUSE WHATSOEVER.
All transaction are subject to Mumbai Jurisdiction.
23

Download
Advertisement