PATIENT MANUAL
LATITUDE
™
Communicator
About This Manual
This manual applies to Models 6280 and 6290
LATITUDE Communicators. Unless specified as applying to a particular model, instructions apply to both.
The model number for your Communicator is located on its bottom label.
When color is used in this manual to explain operation of the Communicator, an indicator shown as gray means that it is not lit. An indicator shown as any other color, including white, means that it is lit.
Follow the instructions in this manual when using the Communicator. Keep all of your
Communicator information in a convenient location for easy access in the future.
LATITUDE is a trademark of
Boston Scientific Corporation or its affiliates.
GlobTek is a trademark of GlobTek, Inc.
MultiConnect is a trademark of Multi-Tech Systems, Inc.
SL Power Electronics is a trademark of SL Delaware Holdings, Inc.
LATITUDE ™ Communicator Patient Manual i
ii
LATITUDE ™ Communicator Patient Manual
Table of Contents
PATIENT MANAGEMENT SYSTEM ..................... 1
The LATITUDE Communicator ................................. 2
Components of Your Communicator .................. 4
Optional Accessories ................................ 5
The Clinician Website ............................................... 5
USING YOUR COMMUNICATOR ............................ 6
Important Notes ........................................................ 6
Where to Place Your Communicator ........................ 7
Heart Button and Indicators ...................................... 9
Heart Button and Indicator Descriptions ........... 11
Normal Operation of the Communicator ........... 17
Using the Heart Button ..................................... 18
Status Button .......................................................... 21
Confirming Successful Operation ..................... 21
Clinician Website ........................................... 22
Canceling an Interrogation ..................................... 23
Loss of Power ......................................................... 23
Traveling With Your Communicator ........................ 23
Care and Maintenance ........................................... 24
Cleaning the Communicator and Accessories .. 25
Returning, Replacing, or Disposing of the
Communicator or Accessories ...................... 26
LATITUDE ™ Communicator Patient Manual iii
SETTING UP YOUR COMMUNICATOR ................ 27
Setup Overview ...................................................... 27
Confirming/Setting Switch Settings ........................ 28
Special Instructions if Using the Standard
Telephone Connection Method ..................... 29
Traveling ................................................. 29
Dial-out or Prefix Number .................... 29
Setting Up Your Connection Method ...................... 31
Cellular Connection .......................................... 33
Using Previous Cellular Connection
Accessories .......................................... 37
Replacement ........................................... 37
Using a USB Ethernet Adapter ...................... 38
Replacement ........................................... 41
Using a Wireless Internet Adapter ................. 42
Replacement ........................................... 47
Standard Telephone Connection ..................... 48
Communicator Use of the Telephone ...... 50
Communicator is Making a Call ........... 52
DSL Internet Service ............................... 52
Replacement ........................................... 53
Hotspot Connection (Mobile Device) ................ 53
USB Accessory Adapter Connection ................ 54
Software Download and Installation ....................... 55
TROUBLESHOOTING ........................................... 56
Indicator Light Errors .............................................. 57
Yellow Wave Errors ................................................ 65
iv
LATITUDE ™ Communicator Patient Manual
ADDITIONAL INFORMATION ............................... 83
Frequently Asked Questions................................... 83
Specifications ......................................................... 87
Safety and Standards Compliance ......................... 91
Essential Performance ........................................... 96
Software Statement ................................................ 96
Electromagnetic Emissions and Immunity .............. 97
Explanation of Product and Label Symbols ............ 99
LATITUDE ™ Communicator Patient Manual v
List of Figures
Figure 1. Front of Communicator ............................. 9
Figure 2. Status Button .......................................... 21
Figure 3. Location of Switches............................... 28
Figure 4. Dial-out Number Switch Settings (1-3) ... 30
Figure 5. Back of Communicator ........................... 32
Figure 6. Connecting a USB Cellular Adapter ....... 33
Figure 7. Connecting a USB Ethernet Adapter ...... 38
Figure 8. Wireless Internet Adapter–
Connecting USB Accessory Adapter and
Power Supply ...................................................... 42
Figure 9. Wireless Internet Adapter–
Connecting the Wireless Internet Adapter ........... 44
Figure 10. Wireless Internet Adapter–Pairing ........ 45
Figure 11. Connecting a Telephone Cable ............. 48
Figure 12. Connecting a USB Accessory Adapter . 54
vi
LATITUDE ™ Communicator Patient Manual
ABOUT THE LATITUDE
PATIENT MANAGEMENT SYSTEM
The LATITUDE Patient Management System
(“LATITUDE System”) is a remote monitoring system that uses the LATITUDE Communicator to collect data from your implanted device. Your Communicator then sends this data to the Clinician Website for access by your health care provider.
The LATITUDE System is designed to help your health care provider manage your ongoing care in a manner that is convenient for both of you.
The LATITUDE System uses advanced security methods to protect your personal medical information.
Only authorized health care providers have access to your information through the password-protected
Clinician Website.
CAUTION : The LATITUDE System is not meant to assist with health emergencies. If you are not feeling well or need urgent health care, call your health care provider or dial 911.
LATITUDE ™ Communicator Patient Manual
1
The LATITUDE Communicator
The LATITUDE Communicator is an in-home, wireless monitor that automatically collects and sends your implanted device data to the Clinician Website for access by your health care provider.
The Communicator collects data from your implanted device in three different ways:
• Routine Device Checks : The Communicator
“checks in” on your implanted device daily or weekly, depending on what type of implanted device you have. The collected data will be sent to the
Clinician Website only as needed.
• Scheduled Follow-ups : At times set by your health care provider (typically every few months), your Communicator collects and then sends your implanted device data to the Clinician Website.
• Manual : If this feature is enabled by your health care provider, you may initiate the Communicator to read your implanted device by pressing the Heart button on your Communicator. Only use this feature when the Heart button is flashing or when instructed to do so by your health care provider.
2
LATITUDE ™ Communicator Patient Manual
Routine device checks and scheduled follow-ups may happen automatically without your knowledge, or you may need to press the Heart button when it flashes
to complete the process. Refer to “Using the Heart
Button” on page 18 for more information.
Your health care provider may also send periodic updates to your Communicator to change the schedule for reading data from your implanted device.
In order for your Communicator to be able to send your implanted device data to the Clinician
Website, a connection accessory must be set up
on your Communicator. Refer to “Setting Up Your
Communicator” on page 27 for directions. Contact
your health care provider to learn which connection accessory is right for you.
This equipment needs to be installed and put into service in accordance with the information in the provided documentation. Call your health care provider or Patient Services at 1-866-484-3268 if you need assistance setting up or using your
Communicator.
The Communicator does not provide continuous monitoring.
The Communicator does not reprogram or change any functions of your implanted device. Only your health care provider can do this during an office visit.
The Communicator is designed to work only with your implanted device. It will not work with another patient’s implanted device. The Communicator should be used only as authorized by the prescribing physician.
The Communicator is not for use with any implanted device other than a Boston Scientific device.
LATITUDE ™ Communicator Patient Manual
3
Ask your health care provider if you have questions about any risks with using the Communicator or your implanted device. For valuable information about the risks and reliability of your implanted device, refer to your implanted device patient handbook.
Components of Your Communicator
Every LATITUDE Communicator comes with a power supply, a telephone cable, a Quick Start Guide, and this Patient Manual.
The following table lists compatible accessories for your Communicator. Availability of these accessories depends on the method you are using to connect to the Clinician Website. For more information about the accessories or how to obtain them, contact your health care provider or Patient Services at 1-866-484-
3268.
6359
6293
6390
N/A
6454
6295
Boston Scientific
Model Number
N/A
Accessory Name
(as referenced in this manual)
Power supply (replacement)
Connection Accessories
USB cellular adapter (current model)
USB Ethernet adapter
Wireless internet adapter
Telephone cable (replacement)
USB accessory adapter
USB cellular adapter
(previous model)
6456 (MT200A2W
Multi-Tech Model Number)
Analog-to-wireless cellular converter
(previous model)
Optional (must be prescribed by your health care provider)
6487 Weight scale
6452 Blood pressure monitor
4
LATITUDE ™ Communicator Patient Manual
Only use the accessories listed in the table or provided by your health care provider. Accessories acquired elsewhere may not work with your
Communicator.
Optional Accessories
If prescribed by your health care provider, your
Communicator may include a weight scale and blood pressure monitor.
These specially designed products provide additional information to monitor your health. Refer to the handbook that is included with the weight scale and blood pressure monitor for more information.
A USB accessory adapter is included with the weight scale and blood pressure monitor. The USB accessory adapter provides a wireless connection between these products and your Communicator.
Refer to “USB Accessory Adapter Connection” on page 54 for more information.
The Clinician Website
Between office visits, the Clinician Website gives your health care provider access to the implanted device data that was collected and sent by your
Communicator. The Clinician Website features advanced analysis and trending tools designed to help your health care provider improve your care.
Your implanted device information is typically available on the Clinician Website within 15 minutes of when your Communicator sent it. However, it may sometimes take longer due to external factors.
LATITUDE ™ Communicator Patient Manual
5
USING YOUR COMMUNICATOR
Before you can use your Communicator, you must first set it up to connect to the Clinician Website. Refer
to “Setting Up Your Communicator” on page 27 for
directions on setting up your connection accessory.
Contact your health care provider to learn which connection accessory is right for you.
Important Notes
Check your Communicator every day to see if any of the indicators are lit solid or flashing. Refer to
“Heart Button and Indicators” on page 9 and the
Troubleshooting section starting on page 56 for
more information on the meaning of indicator lights.
Call your health care provider if the Call
Doctor Icon lights red (flashing or solid).
It is very important that the Communicator is always plugged into an electrical outlet that has power.
• Electrical safety: It is recommended that you install a surge protector between the electrical wall outlet and the Communicator. This is to avoid damage to the Communicator caused by local lightning strikes and other electrical surges. Electrical cable wall plugs and other accessories must be in good condition before use.
6
LATITUDE ™ Communicator Patient Manual
Where to Place Your Communicator
Place your Communicator:
• Near an electrical outlet that is easily accessible.
• Within 10 feet (3 meters) from your bedside or where you sleep. If this is not possible, place your Communicator where you spend a considerable amount of time each day.
• Where you can sit comfortably and see the front of the Communicator.
• Where the Communicator and all its cables and accessories will be kept dry and not exposed to humidity or potential water contact.
• Refer to the following sections for more placement advice depending on your connection method:
• “Cellular Connection” on page 33
• “Internet Connection–Using a USB Ethernet
• “Internet Connection–Using a Wireless
• “Standard Telephone Connection” on page
• Some household appliances and other sources of electromagnetic energy could interfere with wireless communication between the Communicator and your implanted device. When you are using the
Communicator, it should be at least 3 feet (1 meter) away from televisions, digital video disc (DVD) players, personal computers, modems, routers, and other electronic equipment.
LATITUDE ™ Communicator Patient Manual
7
• If you have an S-ICD implanted device supported on LATITUDE, the wireless communication between the Communicator and your S-ICD is sensitive to distance and orientation. You may need to move closer to the Communicator, or you may need to position your body such that a clear signal exists between your S-ICD and the Communicator. If you need assistance, contact Patient Services at 1-866-
484-3268.
• Boston Scientific personnel may contact you or your health care provider if it is determined that your implanted device is using too much radio-frequency
(RF) telemetry due to the placement of your
Communicator. Boston Scientific will give advice on better Communicator placement to correct this issue.
8
LATITUDE ™ Communicator Patient Manual
Heart Button and Indicators
The following figure shows the Heart button and all the indicators on the front of your Communicator. Use this figure for reference as you follow this manual’s instructions for using your Communicator.
1 2 3 4 5
6 7 8
(1) Patient icon; (2) Collecting Waves; (3) Heart button; (4) Sending
Waves; (5) Doctor icon; (6) Sensor Reading icon; (7) LATITUDE indicator; (8) Call Doctor icon
Figure 1. Front of Communicator
The Heart button and indicators are intended to inform you of the status of your Communicator or actions you may need to take. The lights, colors, and sequence of
each indicator shown in Figure 1 are explained in the
following section.
LATITUDE ™ Communicator Patient Manual
9
Note : When the words “interrogate” or “interrogation” are used in this manual, it means that the
Communicator is collecting data from your implanted device.
If indicators light other than as explained in this section, refer to the applicable error in the
Troubleshooting section starting on page 56 to find
out if you need to take any action.
10
LATITUDE ™ Communicator Patient Manual
Heart Button and Indicator Descriptions
Heart Button
• A flashing white Heart button indicates:
• Setup is occurring (refer
• You need to complete a scheduled follow-up
(interrogation).
Press the Heart button to complete.
• A solid white light for 2 minutes means the interrogation is complete. Note that the solid white light may appear dim.
• An unlit Heart button may also be used to manually initiate an interrogation of your implanted device. Only press an unlit
Heart button when instructed to do so by your health care
before pressing this button.
LATITUDE ™ Communicator Patient Manual
11
Patient Icon
Shows the Communicator is interrogating your implanted device.
• Lights solid blue when the
Heart button is pressed and an interrogation has started.
• Lights solid blue for 2 minutes after a successful interrogation.
Collecting Waves
Shows the Communicator is interrogating your implanted device.
• Each wave flashes green in sequence and repeats, showing the Communicator is interrogating your implanted device.
• All three waves light green for 2 minutes to indicate the interrogation was a success.
12
LATITUDE ™ Communicator Patient Manual
Sending Waves
Shows the Communicator is connecting to the Clinician
Website.
• Each wave flashes green in sequence and repeats, showing a connection to the Clinician Website is in progress.
• All three waves light green for 2 minutes to indicate the connection to the Clinician
Website was a success and any collected device data was sent.
Doctor Icon
Lights blue for 2 minutes to indicate the Communicator has successfully connected to the Clinician Website. The
Communicator sends any data it has collected from your implanted device or prescribed weight scale or blood pressure monitor.
LATITUDE ™ Communicator Patient Manual
13
Sensor Reading Icon
Shows the Communicator has successfully communicated with a prescribed weight scale or blood pressure monitor.
Note : This icon does not apply to your implanted device.
• Flashes green 5 times and lights solid green for 5 minutes to indicate the Communicator successfully received a weight or blood pressure measurement.
14
LATITUDE ™ Communicator Patient Manual
LATITUDE Indicator
Shows the Communicator is connected to electrical power and ready to use. It also shows if the
Communicator startup process is being performed.
• Lights green to indicate the
Communicator is connected to electrical power and is ready to use.
• Flashes yellow briefly after the
Communicator is plugged into electrical power (startup).
• May flash yellow for a longer period of time. This means that new software is being installed on the Communicator.
LATITUDE ™ Communicator Patient Manual
15
Call Doctor Icon
Lights yellow or red (flashing or solid) to signal a problem that you should report to your health care provider. Refer to the applicable error in the Troubleshooting
section starting on page 56 for
more information.
• Flashes yellow briefly after the Communicator is plugged into electrical power (does not require contacting your health care provider). It then turns off after the Communicator completes the startup process.
• Lights solid yellow if the startup process does not complete.
If the Call Doctor icon lights red (flashing or solid), call your health care provider.
16
LATITUDE ™ Communicator Patient Manual
Normal Operation of the Communicator
When operating normally, only the LATITUDE indicator will light green as shown above. None of the other Communicator indicators will typically light when collecting or sending your implanted device data, except when the Heart button has been pressed.
Note : In this manual, a gray heart shown inside the blue circle means that it is not lit; a white heart means that it is lit.
LATITUDE ™ Communicator Patient Manual
17
Using the Heart Button
Always press the Heart button when it is flashing or when told to do so by your health care provider.
Stay next to the Communicator until lights are lit as shown here.
Do not press the Heart button if it is unlit unless instructed to do so by your health care provider.
The following sequence shows the normal light sequence when the Heart button is pressed.
1. The Communicator begins interrogating your implanted device after the Heart button is pressed.
18
LATITUDE ™ Communicator Patient Manual
2. The Patient icon lights blue. The Collecting
Waves flash green in sequence and repeat while the Communicator interrogates your device.
3. All three Collecting Waves light green. The
Heart button lights solid white, showing the interrogation was a success.
4. The Sending Waves flash green in sequence and repeat while the Communicator sends your data to the Clinician Website.
LATITUDE ™ Communicator Patient Manual
19
5. The Doctor icon lights blue showing the
Communicator successfully sent your data to the Clinician Website. The indicators stay lit for 2 minutes to show the entire process was a success. No further action is required.
CAUTION : Normal use of the LATITUDE System has been accounted for in the projected battery life of your implanted device. Pressing the Heart button more often than when the Heart button flashes, or when instructed to do so by your health care provider, may lead to a decrease in the battery life of your implanted device.
20
LATITUDE ™ Communicator Patient Manual
Status Button
Confirming Successful Operation
Periodically press the Status button on the back of
the Communicator (“Figure 2. Status Button”) for
1 second to confirm that it has been successfully collecting data from your implanted device and sending it to your health care provider.
Figure 2. Status Button
The resulting indicators will stay lit for 2 minutes. If you see the following image—all six Collecting and
Sending Waves lit green—your Communicator is working correctly. No further action is needed.
If the indicators are different than the above image, refer to the applicable error in the Troubleshooting
section starting on page 56 to learn what actions
you should take.
LATITUDE ™ Communicator Patient Manual
21
Note : If you pressed the Heart button before pressing the Status button, the Status button will not function until the resulting interrogation is completed or is canceled. For information on canceling an
Confirming Connection to the Clinician
Website
If you have moved your Communicator, changed the connection method, or made other changes to the Communicator, you should confirm that your
Communicator still successfully connects to the
Clinician Website. To do so, press and hold the Status button for more than 3 seconds . The Sending Waves flash green in sequence and repeat.
Note : If both Collecting and Sending Waves light, you did not press the Status button long enough. In that case, wait for the sequence to end. Then press the
Status button again for more than 3 seconds.
Wait a few minutes for the connection to complete.
If all three Sending Waves light a solid green as shown in the following image for 2 minutes, the connection was a success.
If the Sending Waves are other than all lit solid green, refer to the applicable error in the Troubleshooting
section starting on page 56 to learn what actions
you should take.
22
LATITUDE ™ Communicator Patient Manual
Canceling an Interrogation
If you press the Heart button by mistake (not intending to perform an interrogation), press and hold the Heart button again for at least 5 seconds to cancel the interrogation.
The Collecting Waves may flash yellow in sequence and repeat while the interrogation is being canceled.
Loss of Power
The Communicator has internal memory that stores your implanted device data and other information in case the electrical power is interrupted or the power supply is unplugged. The LATITUDE indicator will transition back to green from being unlit once power is restored to the Communicator.
If the LATITUDE indicator does not transition back to green within 15 seconds after power is restored, unplug the power supply from both the wall outlet and the Communicator for 1 minute . After 1 minute, reconnect the power supply to both. Lights will flash during the transition. If the LATITUDE indicator is still not lit, contact your health care provider or Patient
Services at 1-866-484-3268.
Traveling With Your Communicator
If you will be away from home for an extended period of time (multiple days or weeks), consult with your health care provider to determine whether you should take your Communicator with you. If you take it with you, your health care provider may need to temporarily change your interrogation schedule. If you are traveling outside the country, your health care provider may need to give you information
LATITUDE ™ Communicator Patient Manual
23
about connecting to the Clinician Website in the new country. There may be limitations depending on the country, model of Communicator, and connection method.
In general, telephone connections are limited to specific countries. Cellular connections work in most but not all countries. Internet works everywhere, depending on signal availability. Local limitations may apply.
Contact Patient Services at 1-866-484-3268 for more information.
If you take your Communicator with you, check that the Communicator can connect to the Clinician
Website from your new location. Refer to “Confirming
Connection to the Clinician Website” on page 22.
Care and Maintenance
Your Communicator does not require any regular service, maintenance, or electrical safety testing.
To ensure optimum performance of your
Communicator and accessories and protect them from damage, follow these directions:
CAUTIONS:
• Do not drop or mishandle the Communicator or its accessories in a manner that would cause damage.
• Avoid getting liquid on the unit other than cleaning it as recommended. Do not use abrasive cloth or solvents to clean the unit.
• Do not submerge the Communicator or its accessories in liquid.
24
LATITUDE ™ Communicator Patient Manual
• Do not attempt to open the Communicator or any of its accessories.
• Use this unit as described in this instruction manual.
Use only authorized parts and accessories. Do not attempt to modify or alter this unit or accessories.
If your Communicator or accessories become damaged or malfunction, contact your health care provider or Patient Services at 1-866-484-3268.
Cleaning the Communicator and Accessories
When necessary, clean the Communicator and its accessories with a soft, clean, lint-free cloth moistened in water or mild detergent.
CAUTIONS:
• Do not use other cleaning fluids. They may damage the front of the Communicator. Never spray any cleaning fluid directly on the front of the
Communicator. Do not allow moisture to accumulate on the front of the Communicator, especially on or around the Heart button.
• Avoid using any cleaning fluid near the electrical plugs on the back of the Communicator.
Note that the finish on some types of furniture could be affected as a result of continuous contact with rubber material such as the type used on the base of the Communicator.
LATITUDE ™ Communicator Patient Manual
25
Returning, Replacing, or Disposing of the
Communicator or Accessories
If you need to replace your Communicator or any accessories because of damage or malfunction, or if you need a different model, contact your health care provider or Patient Services at 1-866-484-3268 to learn how to return and replace it.
If you no longer need to use either your
Communicator or any accessories, contact your health care provider or Patient Services to learn how to return them.
Do not throw the Communicator or accessories in the trash. Dispose of them at a local recycling site that accepts electronics. Contact your local authorities to learn how to dispose of them.
Your Communicator may contain private, encrypted health data. Dispose of it only as described above.
26
LATITUDE ™ Communicator Patient Manual
SETTING UP YOUR COMMUNICATOR
Setup Overview
Setting up your Communicator to connect to the
Clinician Website can be done in 2 main steps:
1. Confirm/set the switches on the bottom of your
Communicator. Refer to “Confirming/Setting
2. Use the instructions for one of the following connection methods to connect to the Clinician
Website:
• “Cellular Connection” on page 33
• “Internet Connection–Using a USB Ethernet
• “Internet Connection–Using a Wireless Internet
• “Standard Telephone Connection” on page 48
• “Hotspot Connection (Mobile Device)” on page
Only one connection method can be used with your Communicator—cellular, internet, standard telephone, or hotspot. Using more than one connection method at a time may result in your
Communicator failing to connect to the Clinician
Website.
Stay close to your Communicator during the entire setup process to ensure the best connection between your implanted device and the
Communicator.
LATITUDE ™ Communicator Patient Manual
27
Confirming/Setting Switch Settings
The 8 white switches located on the bottom of your
Communicator must be set correctly for connection to the Clinician Website. The switches are either “on”
(in the up position) or “off” (in the down position). The switches may or may not already be correctly set when you receive your Communicator.
Compare the switch settings shown in Figure 3 to the switch settings on the bottom of your Communicator.
• If they match, no action is needed. If they do not match, slide the switches up or down so that they do match.
• Standard telephone connection only: Switches numbered 1-3 may differ from those shown if a dialout number or prefix is needed to place an outside
telephone call. Refer to “Setting Switches 1-3 for
Dial-out or Prefix Number” on page 29 for those
switch settings.
United States and Puerto Rico
TM
*6290*
Figure 3. Location of Switches
28
LATITUDE ™ Communicator Patient Manual
Special Instructions if Using the Standard
Telephone Connection Method
For more information on setting up the standard
telephone connection, see page 48.
Traveling
If you travel to another country and use a standard telephone to connect to the Clinician Website, you may need to change the country switch settings.
Consult your health care provider or Patient Services at 1-866-484-3268 to learn if you need to change the switch settings when you travel to another country with your Communicator.
Setting Switches 1-3 for Dial-out or Prefix Number
If you are using a standard telephone connection method to connect to the Clinician Website, and if you need to use a dial-out or prefix number to place an outside telephone call, switches 1-3 need to be
changed from the “off” position shown in “Figure 3.
Location of Switches” on page 28. (A dial-out
number to one of the settings shown in “Figure 4.
Dial-out Number Switch Settings (1-3)” on page
30 may be required in a managed care facility or
hotel. For example, if you need to dial a “9” before the number when placing a call, “9” is your dial-out number.)
Note that the telephone service in the facility must be analog, not digital, for the standard telephone connection to work. If you are unsure which telephone mode is available, ask the facility or your service provider.
LATITUDE ™ Communicator Patient Manual
29
To set your Communicator for a dial-out or prefix number, slide switches 1-3 up or down so that they match the settings for the dial-out number shown in the following figure.
Dial-out
Number
Dial-out
Number
None
8
0 9
1
*99
7
Figure 4. Dial-out Number Switch Settings (1-3)
30
LATITUDE ™ Communicator Patient Manual
Setting Up Your Connection Method
This section explains how to set up a connection method on your Communicator. The connection method enables your Communicator to send your implanted device data to the Clinician Website for access by your health care provider.
Your connection method will be one of the following:
• “Cellular Connection” on page 33
• “Internet Connection–Using a USB Ethernet
• “Internet Connection–Using a Wireless Internet
• “Standard Telephone Connection” on page 48
• “Hotspot Connection (Mobile Device)” on page
LATITUDE ™ Communicator Patient Manual
31
The following figure shows the Status button and all the connectors on the back of your
Communicator. Use this figure for reference as you follow this manual’s instructions for setting up your
Communicator with a connection method.
1 2 3 4 5
(1) Status button; (2) USB ports, used for optional accessories and cellular or internet connections; (3) Power input; (4) Port to connect an optional telephone (if using a standard telephone connection); (5)
Telephone jack used for a standard telephone connection
Figure 5. Back of Communicator
32
LATITUDE ™ Communicator Patient Manual
Cellular Connection
When using the cellular connection method, do not use another connection method, such as standard telephone, internet, or hotspot.
The cellular connection only sends data; it does not send voice signals. It is completely separate and cannot be used with your cell phone.
Your cellular connection may be affected by such things as terrain, weather, foliage, buildings and other construction, signal strength, customer equipment, and other factors.
Complete the following steps to set up your
Communicator with a cellular connection to send your data to the Clinician Website. The numbers in
Figure 6 refer to the corresponding steps.
4
Figure 6. Connecting a USB Cellular Adapter
LATITUDE ™ Communicator Patient Manual
33
When using the cellular connection method:
• Place your Communicator in a location where you will get a good cellular signal.
• Place your USB cellular adapter away from electronic products or metal surfaces, and place it alongside the Communicator, not under or on top it.
• Maintain a distance of at least 6 inches (15 centimeters) between the USB cellular adapter and your implanted device.
Refer to “Figure 6. Connecting a USB Cellular
Adapter” on page 33 for steps 1-4.
1. Insert the power supply (included) into the jack labeled .
2. Plug the power supply into an electrical outlet that is easily accessible.
• The LATITUDE indicator will flash yellow for up to 1 minute.
• All the Communicator indicators will light for approximately 1 second.
• If the LATITUDE indicator is not lit, check that both ends of the power supply are plugged in firmly. Check if the light on the power supply is lit.
3. Remove the cap from the USB cellular adapter.
Connect the adapter to the provided USB cable extension.
34
LATITUDE ™ Communicator Patient Manual
4. Insert the USB connector of the cable extension into one of the USB ports labeled on the back of your Communicator.
• The LED light on the USB cellular adapter will blink and remain blinking. At times the light may be lit solid. The light will be off when collecting data from your implanted device and during a
LATITUDE System reboot.
• A SIM card specific for Communicator use only has been pre-installed in the USB cellular adapter. Do not remove or tamper with this SIM card.
5. When the Heart button flashes on your
Communicator, press it.
• Your Communicator’s wave lights will flash green in sequence and repeat for several
minutes as shown in “Using the Heart Button” on page 18.
• If this process takes longer than several minutes, software download and installation may be occurring. If the Heart button flashes
again, press it again. Refer to “Software
Download and Installation” on page 55.
• If you have previously completed initial setup, the Heart button will not flash at this point.
Instead of pressing the Heart button, follow the instructions for pressing the Status button
in “Confirming Connection to the Clinician
6. Your Communicator has successfully connected to the Clinician Website if the lights are lit as shown as follows.
LATITUDE ™ Communicator Patient Manual
35
You can verify the cellular connection by following
the instructions in “Confirming Connection to the
Clinician Website” on page 22. If you travel to
another location with your Communicator, verify the connection from that location.
Setup is complete, and no further action is needed at this time. Leave your Communicator plugged in.
• If the wave lights are not lit a solid green, refer to the applicable error in the Troubleshooting
• If the Sending Waves light yellow, it may indicate the connection failed. Refer to the
Sending Waves sections of “Troubleshooting”
starting on page 72. If your Communicator is
still unable to connect, contact your health care provider or Patient Services at 1-866-484-3268 for assistance.
When using the cellular connection method, keep your Communicator plugged in to the electrical outlet and connected to the USB cellular adapter.
36
LATITUDE ™ Communicator Patient Manual
Using Previous Cellular Connection Accessories
If you have a Model 6295 USB cellular adapter from a previous Communicator, you may continue to use it for cellular connection to the Clinician Website.
If you have a Multi-Tech Systems MultiConnect™
MT200A2W analog-to-wireless cellular converter from a previous Communicator, you may continue to use it for cellular connection to the Clinician Website. The
MultiConnect converter has been tested and found to be compatible with the LATITUDE Communicator.
Replacement
If you need a replacement USB cellular adapter or a different connection accessory (standard telephone, internet, or hotspot), contact your health care provider or Patient Services at 1-866-484-3268.
For information on returning, replacing, or disposing
of your USB cellular adapter, see page 26.
If you wish to discontinue using your USB cellular adapter, contact your health care provider or Patient
Services.
LATITUDE ™ Communicator Patient Manual
37
Internet Connection
–
Using a USB Ethernet
Adapter
When using the internet connection method, do not use another connection method, such as standard telephone, cellular, or hotspot.
Complete the following steps to set up your
Communicator with an internet connection to send your data to the Clinician Website. The numbers in
Figure 7 refer to the corresponding steps.
6
Adapter light
Figure 7. Connecting a USB Ethernet Adapter
When using the internet (USB adapter) connection method, place your Communicator near, but no closer than 3 feet (1 meter), to an internet modem or router.
Refer to “Figure 7. Connecting a USB Ethernet
1. Insert the power supply (included) into the jack labeled .
38
LATITUDE ™ Communicator Patient Manual
2. Plug the power supply into an electrical outlet that is easily accessible.
• The LATITUDE indicator will flash yellow for up to 1 minute.
• All the Communicator indicators will light for approximately 1 second.
• If the LATITUDE indicator is not lit, check that both ends of the power supply are plugged in firmly. Check if the light on the power supply is lit.
For the following steps, make sure you use the
Ethernet cable provided with the USB Ethernet adapter and not the telephone cable provided with the Communicator.
3. Insert the standard (rectangular) end of the USB cable (included with the USB Ethernet adapter) into one of the USB ports on the Communicator labeled .
4. Insert the square end of the USB cable into the end of the USB Ethernet adapter nearest the adapter light.
5. Insert the Ethernet cable (included with the USB
Ethernet adapter) into the opposite end of the adapter.
6. Plug the Ethernet cable into an Ethernet port for your internet service, such as a modem, router, or
Ethernet wall jack.
• The USB Ethernet adapter is properly connected if the green light on the front of the
USB Ethernet adapter is lit (solid or flashing).
7. When the Heart button flashes on the
Communicator, press it.
LATITUDE ™ Communicator Patient Manual
39
• Your Communicator’s wave lights will flash green in sequence and repeat for several
minutes as shown in “Using the Heart Button” on page 18.
• If this process takes longer than several minutes, software download and installation may be occurring. If the Heart button flashes
again, press it again. Refer to “Software
Download and Installation” on page 55.
• If you have previously completed initial setup with a different connection method, the Heart button will not flash at this point. Instead of pressing the Heart button, follow the instructions
for pressing the Status button in “Confirming
Connection to the Clinician Website” on page
8. Your Communicator has successfully connected to the Clinician Website if the lights are lit as shown as follows.
Setup is complete, and no further action is needed at this time. Leave your Communicator plugged in.
• If the wave lights are not lit a solid green, refer to the applicable error in the Troubleshooting
When using the USB Ethernet adapter internet connection method, keep your Communicator plugged in to the electrical outlet and connected to the USB Ethernet adapter.
40
LATITUDE ™ Communicator Patient Manual
Replacement
If you need a replacement internet connection accessory or a different connection method (standard telephone, cellular, or hotspot), contact your health care provider or Patient Services at 1-866-484-3268.
For information on returning, replacing, or disposing of
your internet connection accessory, see page 26.
LATITUDE ™ Communicator Patient Manual
41
Internet Connection
–
Using a Wireless Internet
Adapter
When using the internet connection method, do not use another connection method, such as standard telephone, cellular, or hotspot.
Complete the following steps to set up your
Communicator with an internet connection to send your data to the Clinician Website. The numbers in
Figure 8 refer to the corresponding steps.
3
2
1
Figure 8. Wireless Internet Adapter–Connecting USB
Accessory Adapter and Power Supply
Refer to “Figure 8. Wireless Internet Adapter–
Connecting USB Accessory Adapter and Power
1. Insert the power supply (included) into the jack labeled .
42
LATITUDE ™ Communicator Patient Manual
2. Plug the power supply into an electrical outlet that is easily accessible.
• The LATITUDE indicator will flash yellow for up to 1 minute.
• All the Communicator indicators will light for approximately 1 second.
• If the LATITUDE indicator is not lit, check that both ends of the power supply are plugged in firmly. Check if the light on the power supply is lit.
3. Disconnect all USB devices and telephone cables, if any, from the back of the Communicator. Then insert the USB accessory adapter into one of the
USB ports on the Communicator labeled .
Note: If your Communicator is already using a
USB accessory adapter for the weight scale or blood pressure monitor, it can remain connected and will also be used for the internet (wireless adapter) connection. Only one USB accessory adapter is required.
Complete the following steps to connect your
Communicator wirelessly using the wireless internet adapter.
Refer to “Figure 9. Wireless Internet Adapter–
Connecting the Wireless Internet Adapter” on page 44 for steps 4-8.
LATITUDE ™ Communicator Patient Manual
43
**
8
7
*
4
5 6
* Wireless internet adapter ** Internet modem/router
Figure 9. Wireless Internet Adapter–Connecting the
Wireless Internet Adapter
• Position the Communicator within 100 feet (30 meters) of the wireless internet adapter.
• Some household appliances and other sources of electromagnetic energy could interfere with wireless communication between the
Communicator and the wireless internet adapter.
Avoid placing electronic equipment next to the
Communicator or the wireless internet adapter.
• In addition, barriers between the Communicator and the wireless internet adapter may adversely impact the wireless signal. Avoid physical obstructions between the Communicator and wireless internet adapter whenever possible.
4. Insert the micro end of the USB power cable, included with the wireless internet adapter, into the port on the back labeled “USB.”
5. Insert the standard (rectangular) end of the USB power cable into the USB power adapter, included with the wireless internet adapter.
44
LATITUDE ™ Communicator Patient Manual
6. Plug the USB power adapter into an electrical outlet.
• The power light on the front of the wireless internet adapter will light solid green.
For the following steps, make sure you use the
Ethernet cable provided with the wireless internet adapter and not the telephone cable provided with the Communicator.
7. Insert the Ethernet cable, included with the wireless internet adapter, into the port on the back of the wireless internet adapter labeled
“ETHERNET.”
8. Plug the Ethernet cable into an Ethernet port for your Internet service, such as a modem, router, or
Ethernet wall jack.
9
Figure 10. Wireless Internet Adapter–Pairing
9. To begin pairing, press the button on the back of the wireless internet adapter. The indicator on front will flash green to signal pairing mode is active.
10. When the Heart button flashes on the front
of your Communicator, press it.
LATITUDE ™ Communicator Patient Manual
45
• Your Communicator’s wave lights will flash green in sequence and repeat for several
minutes as shown in “Using the Heart Button” on page 18.
• If this process takes longer than several minutes, software download and installation may be occurring. If the Heart button flashes
again, press it again. Refer to “Software
Download and Installation” on page 55.
• If you have previously completed initial setup, the Heart button will not flash at this point.
Instead, press and hold the Status button on the back of the Communicator for at least
3 seconds to complete pairing. If pairing is successful, you will see solid green Sending
Waves and a blue doctor icon; the Collecting
Waves will not be lit. Refer to “Status Button” on page 21.
11. Your Communicator has successfully connected to the Clinician Website if the wave lights are lit a solid green as shown as follows.
Setup is complete, and no further action is needed at this time. Leave your Communicator plugged in.
• If the wave lights are not lit a solid green, refer to the applicable error in the Troubleshooting
46
LATITUDE ™ Communicator Patient Manual
When using the wireless internet adapter connection method, keep your Communicator and wireless internet adapter plugged in to the electrical outlet. Keep the wireless internet adapter connected to your internet modem/router.
Replacement
If you need a replacement internet connection accessory or a different connection method (standard telephone, cellular, or hotspot), contact your health care provider or Patient Services at 1-866-484-3268.
For information on returning, replacing, or disposing of
your internet connection accessory, see page 26.
LATITUDE ™ Communicator Patient Manual
47
Standard Telephone Connection
When using the standard telephone connection method, do not use another connection method, such as cellular, internet, or hotspot.
Complete the following steps to set up your
Communicator with a standard telephone connection to send your data to the Clinician Website. The
numbers in Figure 11 refer to the corresponding
steps.
*
* Connecting a telephone to your Communicator is optional.
To do so, plug your telephone into the jack labeled .
Your Communicator and a telephone can share the same telephone wall jack. However, they cannot be used at the same time.
Figure 11. Connecting a Telephone Cable
When using the standard telephone connection, place your Communicator near a telephone wall jack.
Refer to “Figure 11. Connecting a Telephone Cable”
for steps 1-4.
48
LATITUDE ™ Communicator Patient Manual
1. Insert the power supply (included) into the jack labeled .
2. Plug the power supply into an electrical outlet that is easily accessible.
• The LATITUDE indicator will flash yellow for up to 1 minute.
• All the Communicator indicators will light for approximately 1 second.
• If the LATITUDE indicator is not lit, check that both ends of the power supply are plugged in firmly. Check if the light on the power supply is lit.
3. Plug one end of the Communicator telephone cable (included) into the jack labeled .
4. Plug the other end of the cable into the telephone jack on the wall.
Note : If you have DSL internet service, you may need to use a DSL filter between the telephone
wall jack and the Communicator. Refer to “DSL
5. When the Heart button flashes on your
Communicator, press it.
• Your Communicator’s wave lights will flash green in sequence and repeat for several
minutes as shown in “Using the Heart Button” on page 18.
• If this process takes longer than several minutes, software download and installation may be occurring. If the Heart button flashes
again, press it again. Refer to “Software
Download and Installation” on page 55.
LATITUDE ™ Communicator Patient Manual
49
• If you have previously completed initial setup, the Heart button will not flash at this point.
Instead of pressing the Heart button, follow the instructions for pressing the Status button
in “Confirming Connection to the Clinician
6. Your Communicator has successfully connected to the Clinician Website if the lights are lit as shown as follows.
Setup is complete, and no further action is needed at this time. Leave your Communicator plugged in.
• If the wave lights are not lit a solid green, refer to the applicable error in the Troubleshooting
When using the standard telephone connection, keep your Communicator plugged in to the electrical outlet and connected to the telephone wall jack.
Communicator Use of the Telephone
When using a standard telephone connection, the Communicator uses your phone line to make telephone calls to send your data to the Clinician
Website. These calls last approximately 5 minutes.
The Communicator can only make outgoing calls. It cannot receive calls.
The Communicator is designed to operate on standard telephone connections like those found in most homes and supports tone dialing over an
50
LATITUDE ™ Communicator Patient Manual
analog line. The Communicator may work on other telephone systems, such as DSL and VoIP, if those systems provide an analog interface for connecting the Communicator. The Communicator should not be connected to a digital phone interface, such as those commonly used in some businesses, hotels, and managed care facilities (nursing homes, skilled care facilities, rehabilitation centers) where telephones are typically provided by the facility. If you are unsure of the features on your telephone, ask your service provider.
If you are using the phone line (“Using the Telephone
While the Communicator is Making a Call” on page
52), the Communicator will wait and attempt to
place a call later. Or if you have other telephone equipment (including fax machine, answering system or computer modem) connected to the same phone line and the line is in use, the Communicator will wait and attempt to place a call later. If you have heavy phone line usage that delays or prevents the
Communicator from placing or completing phone calls, it may be appropriate to install an additional telephone line.
Your Communicator and a telephone can share the same telephone wall jack; however, they cannot be used at the same time. The Communicator will relinquish control of the telephone line shortly after you pick up the phone, provided that the telephone
line meets the specifications stated on page 87.
LATITUDE ™ Communicator Patient Manual
51
Using the Telephone While the Communicator is
Making a Call
If you pick up the phone while the Communicator is using the telephone line, there will be no dial tone.
Hang up the receiver, wait 3 or more seconds, and then pick up the telephone receiver again. The
Communicator should disconnect and dial tone will be restored.
If the Communicator does not disconnect and restore dial tone, hang up the receiver. Then unplug the
Communicator from electrical power. You can then use your phone. Plug the Communicator back in after you have finished using the phone.
The Communicator will attempt to reconnect later.
DSL Internet Service
If you have digital subscriber line (DSL) internet service provided through your telephone line, you may need to install a DSL filter between the wall phone jack and the LATITUDE Communicator.
Most DSL filters are small rectangular devices with standard telephone jack connectors at each end.
These filters are typically provided by DSL service providers to connect telephones, an answering machine, or a fax machine to your telephone line.
If you use DSL filters for such devices, you will need to install a DSL filter to use the Communicator. If you use a dual-port DSL filter, connect the Communicator to the port labeled PHONE or where you would typically connect a telephone. For assistance, contact your DSL service provider or LATITUDE Patient
Services at 1-866-484-3268.
52
LATITUDE ™ Communicator Patient Manual
Replacement
If you need a replacement telephone cable or a different connection accessory (cellular, internet, or hotspot), contact your health care provider or Patient
Services at 1-866-484-3268.
For information on returning, replacing, or disposing
of your telephone cable, see page 26.
Hotspot Connection (Mobile Device)
The hotspot feature on your mobile device may be used for a wireless connection to the Clinician
Website.
To use hotspot, you must have the USB accessory adapter plugged into your Communicator. (See
the following section, “USB Accessory Adapter
Connection”.) The pairing PIN number is “123456”.
Enable hotspot and Bluetooth® on your mobile device while near your Communicator for at least 1 hour each day and for manual device interrogations. This allows enough time for the Communicator to contact the LATITUDE System. You may incur charges from your mobile phone network provider. For assistance, contact your mobile device service provider or Patient
Services at 1-866-484-3268.
LATITUDE ™ Communicator Patient Manual
53
USB Accessory Adapter Connection
The USB accessory adapter is used to establish a wireless connection between the prescribed weight scale and blood pressure monitor and your
Communicator.
The USB accessory adapter may also be used to connect your Communicator to the Clinician Website
using a hotspot connection, as described in “Hotspot
Connection (Mobile Device)” on page 53.
Figure 12. Connecting a USB Accessory Adapter
Plug the USB accessory adapter into either of the USB ports labeled on the back of the
Communicator.
Leave the USB accessory adapter plugged into the Communicator so it can receive data when you use your prescribed weight scale or blood pressure monitor. The USB accessory adapter also must stay plugged into your Communicator if you are using a hotspot connection to the Clinician Website.
Note: If your Communicator is already using a USB accessory adapter for the internet (wireless adapter) or hotspot, it can remain connected and will also be used for the weight scale and blood pressure monitor.
Only one USB accessory adapter is required.
54
LATITUDE ™ Communicator Patient Manual
Software Download and Installation
Updated software may occasionally be made available to your Communicator for download and installation.
During initial Communicator setup: If a software update is waiting, pressing the Heart button will trigger the download and installation process, which could take an additional several minutes. Wait for the
Heart button to flash again, then press it. Follow the remaining setup steps for the connection method you are using.
During normal use, with Communicator already set up : Software download and installation may happen without your knowledge. No action is required.
LATITUDE ™ Communicator Patient Manual
55
TROUBLESHOOTING
This Troubleshooting section first shows various combinations of indicator lights that signal an error, and then shows Yellow Wave light errors.
A description of the issues, actions to take, and verification steps, as applicable, are shown for each type of error.
For clarity, only the pertinent error colors are shown in the images in this Troubleshooting section. A white
Heart in the Heart button means it is lit; a gray Heart means it is not lit.
If none of the steps in this Troubleshooting section work to resolve the error, try resetting your
Communicator by unplugging it from the electrical outlet, waiting 1 minute, then plugging it back in.
56
LATITUDE ™ Communicator Patient Manual
Indicator Light Errors
►
Heart Button is Flashing
►
LATITUDE Indicator is Green
Issue:
Action:
Verify:
You need to complete a scheduled interrogation or perform a manual device check.
Press the Heart button to complete setup or the interrogation. Refer to
“Using the Heart Button” on page 18
for the light sequence when the Heart button is pressed.
• After pressing the Heart button, if the indicators are lit as shown below, the interrogation or device check was successful.
• If the indicators are not lit as shown above, refer to the applicable error in the Yellow Wave Errors section
LATITUDE ™ Communicator Patient Manual
57
►
No Indicators are Lit
Issue:
Action:
• The Communicator is not connected to electrical power or it is not functioning.
• The Communicator has just been plugged into electrical power or may be downloading and installing software. This process typically lasts
5 minutes but may take longer.
• Check that both ends of the power supply are plugged in firmly.
• Check if the light on the power supply is lit. Make sure the electric outlet is active, or try a different outlet.
• Unplug the power supply from both the wall outlet and the
Communicator for 1 minute . After 1 minute, reconnect the power supply to both. Lights will flash during the transition.
• If the above actions do not resolve the issue, wait 5 minutes for a possible software update to complete.
58
LATITUDE ™ Communicator Patient Manual
Verify: • If indicator lights flash, and then you get a solid green LATITUDE indicator as shown below, the issue is resolved.
• If all indicators are still unlit, including the LATITUDE indicator, contact your health care provider or
Patient Services at 1-866-484-3268.
LATITUDE ™ Communicator Patient Manual
59
►
LATITUDE Indicator is Flashing Yellow
►
No Other Indicators are Lit
Issue:
Action:
Verify:
The Communicator has just been plugged into electrical power or may be downloading and installing software. This process typically lasts 5 minutes but may take longer.
Wait 5 minutes for a possible software update to complete.
• If indicator lights flash, and then you get a solid green LATITUDE indicator as shown below, the issue is resolved.
• If the LATITUDE indicator is still flashing yellow, contact your health care provider or Patient Services at
1-866-484-3268.
60
LATITUDE ™ Communicator Patient Manual
►
Call Doctor Icon is Red (Flashing or Solid)
►
LATITUDE Indicator is Yellow
Issue:
Action:
• A potential problem with your implanted device was detected, but the Communicator cannot send any information collected from your implanted device to the Clinician
Website.
• The Call Doctor icon and
LATITUDE indicator will remain lit solid as shown until the problem is resolved.
Your immediate response is required.
Call your health care provider.
LATITUDE ™ Communicator Patient Manual
61
►
Call Doctor Icon is Yellow (Flashing or Solid)
►
LATITUDE Indicator is Yellow
Issue:
Action:
• This indicates one of the following errors:
• Your Communicator is currently unable to read your implanted device or send its data to the
Clinician Website.
• Monitoring of your implanted device was suspended.
• The Call Doctor icon and LATITUDE indicator will remain lit solid yellow as shown until the problem is resolved.
Unplug the power supply from both the wall outlet and the Communicator for 1 minute . After 1 minute, reconnect the power supply to both.
Lights will flash during the transition.
62
LATITUDE ™ Communicator Patient Manual
Verify: • If successful, the LATITUDE indicator will light green as shown below.
• If the Call Doctor icon and
LATITUDE indicator remain yellow, contact your health care provider or
Patient Services at 1-866-484-3268.
LATITUDE ™ Communicator Patient Manual
63
►
Call Doctor Icon is Solid Yellow
►
LATITUDE Indicator is Not Lit
Issue:
Action:
Verify:
This indicates your Communicator is having a problem connecting.
Unplug the power supply from both the wall outlet and the Communicator for 1 minute . After 1 minute, reconnect the power supply to both. Lights will flash during the transition.
• If successful, the LATITUDE indicator will light green as shown below.
• If the Call Doctor icon remains yellow, you may need a replacement Communicator.
Contact your health care provider or
Patient Services at 1-866-484-3268.
64
LATITUDE ™ Communicator Patient Manual
Yellow Wave Errors
Yellow Wave light errors stay lit for 60 minutes unless the error is resolved sooner. The LATITUDE indicator is lit yellow at the same time. After 60 minutes, all wave lights are turned off and the LATITUDE indicator is lit green, even if the problem was not resolved.
If you suspect the Yellow Wave light errors are still an issue after the wave lights are turned off, press the
Status button for 1 second
Button” on page 21 to verify the error. Then refer to
the applicable Yellow Wave error in this section.
LATITUDE ™ Communicator Patient Manual
65
►
One Yellow Collecting Wave
Issue:
Action:
The Communicator was unable to start an interrogation of your implanted device, or your implanted device was out of range at the time of the attempted interrogation.
• Ensure the Communicator is optimally placed as described
• Face the Communicator. Sit directly in front of the Communicator. Make sure you are within 3 feet (1 meter) of the Communicator.
• Move any wireless electronic products (such as cordless or cellular phones, baby monitors, or modems/routers) at least 3 feet (1 meter) away from the
Communicator.
• Press the Heart button to start another interrogation. Refer to
“Using the Heart Button” on page
18 for the light sequence when
the Heart button is pressed.
66
LATITUDE ™ Communicator Patient Manual
Verify: • If the indicators are lit as shown below, the interrogation was a success.
• If one Yellow Collecting Wave remains, contact your health care provider or Patient Services at
1-866-484-3268.
• If other Yellow Wave errors remain, refer to the applicable error in this section.
LATITUDE ™ Communicator Patient Manual
67
►
Two Yellow Collecting Waves
Issue:
Action:
The Communicator started but was not able to complete the interrogation within the time allowed.
• Ensure the Communicator is optimally placed as described
• Face the Communicator. Sit directly in front of the Communicator. Make sure you are within 3 feet (1 meter) of the Communicator.
• Remain still until the interrogation is complete, as shown in the Verify
section on page 69. Do not move
away from the Communicator.
• Move any wireless electronic products (such as cordless or cellular phones, baby monitors, or modems/routers) at least 3 feet (1 meter) away from the
Communicator.
• Press the Heart button to start another interrogation. Refer to
“Using the Heart Button” on page
18 for the light sequence when
the Heart button is pressed.
68
LATITUDE ™ Communicator Patient Manual
Verify: • If the indicators are lit as shown below, the interrogation was a success.
• If two Yellow Collecting Waves remain, contact your health care provider or Patient Services at
1-866-484-3268.
• If other Yellow Wave errors remain, refer to the applicable error in this section.
LATITUDE ™ Communicator Patient Manual
69
►
Three Yellow Collecting Waves
Issue:
Action:
One of the following reasons could cause this error:
• You may have exceeded your weekly interrogation limit, or you may not be allowed to use the Heart button.
• You may be sitting too close to your modem/router.
• If you suspect you may have exceeded your weekly interrogation limit or are not allowed to use the
Heart button, contact your health care provider or Patient Services at
1-866-484-3268.
• Move at least 3 feet (1 meter) away from your modem/router.
• Press the Heart button to start another interrogation. Refer to
“Using the Heart Button” on page
18 for the light sequence when
the Heart button is pressed.
70
LATITUDE ™ Communicator Patient Manual
Verify: • If the indicators are lit as shown below, the interrogation was a success.
• If three Yellow Collecting Waves remain, contact your health care provider or Patient Services at
1-866-484-3268.
• If other Yellow Wave errors remain, refer to the applicable error in this section.
LATITUDE ™ Communicator Patient Manual
71
►
One Yellow Sending Wave
Issue:
Action if using a cellular connection:
An attempt to connect to the Clinician
Website failed due to issues relating to the cellular, internet, or telephone connection.
• Make sure the USB cellular adapter is plugged into the Communicator.
• Unplug the Communicator from the electrical outlet, wait 1 minute , then plug it back in.
• Move the Communicator to another location that may have better cellular reception.
• Press the Status button for
3 seconds as explained in
Clinician Website” on page 22.
Then proceed to the Verify section
72
LATITUDE ™ Communicator Patient Manual
Action if using an internet
(USB adapter) connection:
• Make sure the USB cable provided with the USB Ethernet adapter is connected at one end to the USB
Ethernet adapter and at the other end to the USB port on the back of the Communicator.
• Make sure the Ethernet cable provided with the USB Ethernet adapter is firmly connected at one end to the USB Ethernet adapter and at the other end to the Ethernet port for your internet service.
• If the green light on the front of the
USB Ethernet adapter is not on, make sure the internet modem or router is powered on.
• Press the Status button for
3 seconds as explained in
Clinician Website” on page 22.
Then proceed to the Verify section
LATITUDE ™ Communicator Patient Manual
73
Action if using an internet
(wireless adapter) connection:
• Make sure the wireless internet adapter is powered on by verifying that the power light on the front is lit solid green.
• Make sure the USB accessory adapter is connected to the back of the Communicator. No other USB devices or phone cables should be connected to the back of the
Communicator.
• Make sure the wireless internet adapter is within 100 feet (30 meters) of your Communicator.
Avoid placing the Communicator or wireless internet adapter near electronic devices and physical obstructions.
• Make sure the wireless internet adapter is paired with your
Communicator by repeating the pairing process. Follow steps 9 and
10 in “Internet Connection–Using a
Wireless Internet Adapter” on page
• Press the Status button for
3 seconds as explained in
Clinician Website” on page 22.
Then proceed to the Verify section
74
LATITUDE ™ Communicator Patient Manual
Action if using a standard telephone connection:
• Check that the telephone cable is plugged in tightly to a telephone wall jack and the Communicator.
• Pick up the telephone that is using the same telephone wall jack as the
Communicator, and check for dial tone. If no dial tone, try a different telephone wall jack.
• If you have DSL internet service, ensure you are using a DSL filter between the Communicator and the telephone wall jack.
• Check that the analog telephone service supports the tone dialing mode.
• Press the Status button for
3 seconds as explained in
Clinician Website” on page 22.
Then proceed to the Verify section
LATITUDE ™ Communicator Patient Manual
75
Verify (all connection types):
• If the connection was a success, the indicators will be lit as shown below.
• If one Yellow Sending Wave remains, contact your health care provider or Patient Services at
1-866-484-3268.
• If other Yellow Wave errors remain, refer to the applicable error in this section.
76
LATITUDE ™ Communicator Patient Manual
►
Two Yellow Sending Waves
Issue:
Action if using a cellular connection:
An attempt to connect to the Clinician
Website failed due to issues relating to the cellular, internet, or telephone connection.
• Move the Communicator to another location that may provide a stronger cellular signal.
• Press the Status button for
3 seconds as explained in
Clinician Website” on page 22.
Then proceed to the Verify section
LATITUDE ™ Communicator Patient Manual
77
Action if using an internet connection:
• If using the USB adapter, make sure the Ethernet cable provided with the USB Ethernet adapter is connected to the Ethernet port for your internet service.
• If using the wireless adapter, make sure the USB accessory adapter is connected to the back of the
Communicator. No other USB devices or phone cables should be connected to the back of the
Communicator.
• Press the Status button for
3 seconds as explained in
Clinician Website” on page 22.
Then proceed to the Verify section
78
LATITUDE ™ Communicator Patient Manual
Action if using a standard telephone connection:
• Make sure your telephone is not being used at this time.
• Pick up the telephone that is using the same telephone wall jack as the
Communicator, and check for dial tone. If no dial tone, try a different telephone wall jack.
• Remove any splitters between the
Communicator and the telephone wall jack.
• If you have DSL internet service, ensure you are using a DSL filter between the Communicator and the telephone wall jack.
• Check that the switches on the bottom of the Communicator are set correctly for your country and whether you need to dial a number to get an outside line. Refer to
“Confirming/Setting Switch Settings” on page 28.
• Press the Status button for
3 seconds as explained in
Clinician Website” on page 22.
Then proceed to the Verify section
LATITUDE ™ Communicator Patient Manual
79
Verify (all connection types):
• If the connection was a success, the indicators will be lit as shown below.
• If two Yellow Sending Waves remain, contact your health care provider or
Patient Services at 1-866-484-3268.
• If other Yellow Wave errors remain, refer to the applicable error in this section.
80
LATITUDE ™ Communicator Patient Manual
►
Three Yellow Sending Waves
Issue:
Action for any type of connection:
Action if using an internet connection:
The Communicator was able to establish a connection to the Clinician
Website, but no information reached it.
Check that the switches on the bottom of the Communicator are set correctly for your country and whether you need to dial a number to get an
outside line. Refer to “Confirming/
Setting Switch Settings” on page
• Make sure that other computers or devices connected to your internet modem or router are able to access the internet.
• If using the wireless adapter, make sure the wireless internet adapter is connected to your internet modem or router with the Ethernet cable.
LATITUDE ™ Communicator Patient Manual
81
Verify (all connection types):
• If the connection was a success, the indicators will be lit as shown below.
• If three Yellow Sending Waves remain, contact your health care provider or Patient Services at
1-866-484-3268.
• If other Yellow Wave errors remain, refer to the applicable error in this section.
82
LATITUDE ™ Communicator Patient Manual
ADDITIONAL INFORMATION
Frequently Asked Questions
These FAQs are designed to point you to the right section in this manual for the answers.
What should I do if the Heart button is flashing?
Press the Heart button to complete a scheduled interrogation. A flashing Heart button does not indicate there is a problem with your implanted device. Refer
to “Using the Heart Button” on page 18.
Does the Communicator call 911 in an emergency?
No. The LATITUDE System is not meant to assist with health emergencies. If you are not feeling well, call your health care provider or dial 911. Refer to “About the LATITUDE Patient Management System” on page
1.
Where should I place my Communicator?
Refer to “Where to Place Your Communicator” on page 7.
How do I set up my Communicator using a
USB cellular adapter?
Refer to “Cellular Connection” on page 33.
LATITUDE ™ Communicator Patient Manual
83
How do I set up my Communicator using a
USB Ethernet adapter?
Refer to “Internet Connection–Using a USB Ethernet
How do I set up my Communicator using the wireless internet adapter?
Refer to “Internet Connection–Using a Wireless
How do I set up my Communicator using a standard telephone connection?
Refer to “Standard Telephone Connection” on page
How do I know the Communicator is working?
Refer to “Heart Button and Indicator Descriptions”
on page 11 and “Normal Operation of the
What do these lights mean?
See the following chart, and refer to “Heart Button
and Indicators” on page 9 or “Troubleshooting” on page 56.
84
LATITUDE ™ Communicator Patient Manual
OR
If you see ...
OR
It means ...
The Communicator needs help completing a scheduled device check.
Note : This does not indicate a problem with your implanted device.
Data from your implanted device has been sent to the
Clinician Website.
There is a potential problem that needs to be addressed by your health care provider.
Any Yellow Waves or Yellow Call Doctor icon means your
Communicator is having a problem connecting or monitoring has been suspended.
Do this ...
Press the Heart button.
Stay next to the
Communicator until all lights are as shown in the next row.
No further action required.
Call your health care provider.
Refer to the applicable error in the Troubleshooting section starting on
How do I manually send my data?
Refer to “Using the Heart Button” on page 18.
When do I use my Communicator?
Refer to “The LATITUDE Communicator” on page
2 and “Using the Heart Button” on page 18.
What do I need to do with my Communicator if I travel?
Refer to “Traveling With Your Communicator” on page
LATITUDE ™ Communicator Patient Manual
85
How do I dispose of my Communicator and
Accessories?
Refer to “Returning, Replacing, or Disposing of the
Communicator or Accessories” on page 26.
Where can I go for more help?
Contact your health care provider or Patient Services at 1-866-484-3268.
86
LATITUDE ™ Communicator Patient Manual
Specifications
Model:
Dimensions:
Weight:
Power Source
(included):
6280 and 6290
(Unless specified, values apply to all models.)
Length: 8.00 in (20.3 cm)
Width: 4.50 in (11.4 cm)
Height: 2.71 in (6.9 cm)
0.83 lbs (0.38 kg)
5.0 VDC, 3.0 A, continuous service Class II
AC adapter (power supply):
Power Supply Input:
GlobTek ™ GTM41061-1512-7.0 or
SL Power Electronics
MENB1020A0540C02
™
100-240 VAC, 0.6 A, 50-60 Hz
Maximum Output: 15 W
Supply Mains Isolation: AC adapter (power supply) plug
Minimum Operational
Loop Current:
Protection against electric shock:
20 mA
Class II
Expected Service Life: Up to 15 years
Analog Dialing Mode: Tone
Operating Temperature: 41° F to 104° F
(5° C to 40° C)
Storage and Transport
Temperature*:
-13° F to 158° F
(-25° C to 70° C)
Operating Humidity: 15% to 93% noncondensing
LATITUDE ™ Communicator Patient Manual
87
Storage and Transport
Humidity*:
Operating Pressure:
Up to 93% noncondensing
70 to 106 kPa
Storage and Transport
Pressure*:
Protection Against
Ingress of Solid Foreign
Objects:
50 to 106 kPa
IP21 (≥12.5 mm diameter)
Protection Against
Ingress of Water:
IP21 (light rain proof)
* Storage and transport specifications apply with or without
Communicator protective packaging.
Communicator Implanted Device Radio ( Model 6280 ):
Receive Bandwidth: +190/-160 kHz
Frequency Band:
Modulation Transmit
Type:
Effective Radiated
Power:
916.5 MHz
ASK
(Amplitude-Shift Keying)
<-1.25 dBm (0.75 mW)
Communicator Implanted Device Radio ( Model 6290 ):
Receive Bandwidth: <300 kHz
MICS/MedRadio: 402-405 MHz
Modulation Transmit
Type:
Effective Radiated
Power:
FSK
(Frequency-Shift Keying)
<-16 dBm (25 µW)
88
LATITUDE ™ Communicator Patient Manual
USB Accessory Adapter:
2.4 GHz wireless USB dongle
Boston Scientific Model 6454
(included with weight scale and blood pressure monitor;
may also be available separately)
Operational
Frequency:
Modulation Type:
2400.0 to 2480.0 MHz
Adaptive Frequency Hopping
Effective Radiated
Power:
Operating
Temperature:
Storage and
Transport
Temperature:
+19.4 dBm (87.1 mW)
32° F to 158° F
(0° C to 70° C)
-4° F to 185° F
(-20° C to 85° C)
Operating Humidity: 10% to 85% noncondensing
Storage and
Transport Humidity: 10% to 85% noncondensing
LATITUDE NXT USB Cellular Adapter (Model 6295):
GSM-850:
PCS-1900:
W-CDMA 850:
W-CDMA 1900:
TX 824-849 MHz
RX 869-894 MHz
Effective Radiated Power: 22.93 dBm
TX 1850-1910 MHz
RX 1930-1990 MHz
Effective Radiated Power: 26.42 dBm
TX 824-849 MHz
RX 869-894 MHz
Effective Radiated Power: 15.83 dBm
TX 1850-1910 MHz
RX 1930-1990 MHz
Effective Radiated Power: 18.76 dBm
LATITUDE ™ Communicator Patient Manual
89
Network and Connectivity Specifications
Ethernet:
Required Characteristics of IT Network
IEEE 802.3, 10 Mbps
IEEE 802.3u, 100 Mbps
Wi-Fi:
Hazardous situations
resulting from network
failure:
None
The Communicator fails to report a potential problem with the implanted device to the Clinician Website
Required Configuration of IT Network
Ethernet:
Internet protocol:
Static IP addressing
Wi-Fi: None
Ethernet MAC address: On dongle label
IPv4
Dynamic Host
Configuration Protocol
(DHCP) mode:
Wi-Fi MAC address:
Automatic DHCP mode supported
None
90
LATITUDE ™ Communicator Patient Manual
Safety and Standards Compliance
• Changes or modifications not expressly approved by Boston Scientific could void the user’s authority to operate this equipment.
• Allow 10 minutes for the Communicator to return to the ambient temperature (68° F, 20° C, or as applicable) when starting from the storage temperature limits.
• The Communicator is of a type not intended to be repaired. (47 C.F.R. Part 68)
• Before each use, visually inspect your
Communicator to make sure the housing has no cracks and the AC adapter (power supply) and any other connecting items are intact.
• The use of accessories and cables other than those specified may result in increased emissions or decreased immunity of the LATITUDE
Communicator.
• Keep your Communicator and all accessories out of the reach of small children and pets. Small parts may cause choking or serious injury if swallowed and attached cords may pose a strangulation hazard. Consult a health care professional immediately if this occurs.
• Do not insert any object other than a phone connector into the phone jacks on the back of the Communicator. There can be voltage on the electrical contacts in the jacks. There is potential to receive a shock.
• Do not use the Communicator adjacent to or stacked with other equipment. If it is necessary to use the Communicator adjacent to or stacked with
LATITUDE ™ Communicator Patient Manual
91
other equipment, please contact your health care provider or Patient Services at 1-866-484-3268 to verify normal operation.
• Do not use the Communicator in the presence of flammable gas mixtures, including anesthetics, oxygen, or nitrous oxide.
• The user is cautioned to maintain an 8 in. (20 cm) spacing from the product to ensure compliance with Federal Communications Commission/Industry
Canada (FCC/IC) requirements.
• To help prevent electromagnetic interference, it may be necessary to keep other wireless communications equipment such as cellular telephones and their base stations, mobile phones, and wireless home network devices at least 12 in.
(30 cm) away from the Communicator.
• Other wireless communication equipment could interfere with the Communicator even if the other equipment complies with CISPR (Special
International Committee on Radio Interference) emission requirements.
• This device complies with Title 47, Part 15, of the
FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
• This equipment complies with Part 68 of the
FCC rules and the requirements adopted by the
Administrative Council for Terminal Attachments
(ACTA). On the bottom of this equipment is a label that contains, among other information, a product identifier in the format US: AAAEQ##TXXX. If
92
LATITUDE ™ Communicator Patient Manual
requested, this number must be provided to the telephone company. The Ringer Equivalence
Number (REN) for this product is part of the product identifier. The digits represented by ## are the REN.
• The REN is used to determine the number of devices that may legally connect to a telephone line. In most, but not all areas, the sum of RENs should not exceed five (5.0). You should contact your telephone company to determine the maximum
REN for your calling area.
• This equipment uses the following Universal Service
Order Codes (USOC) jacks: RJ11C.
• An FCC compliant telephone cord and modular plug are provided with this equipment, which is designed to connect to the telephone network or premises wiring using a Part 68 compliant compatible jack.
See installation instructions for details.
• Model 6290 only : This transmitter is authorized by rule under the Medical Device Radiocommunication
Service (in part 95 of the FCC Rules) and must not cause harmful interference to stations operating in the 400.150–406.000 MHz band in the Meteorological Aids (i.e., transmitters and receivers used to communicate weather data), the
Meteorological Satellite, or the Earth Exploration
Satellite Services and must accept interference that may be caused by such stations, including interference that may cause undesired operation.
This transmitter shall be used only in accordance with the FCC Rules governing the Medical Device
Radiocommunication Service. Analog and digital voice communications are prohibited. Although this transmitter has been approved by the Federal
Communications Commission, there is no
LATITUDE ™ Communicator Patient Manual
93
guarantee that it will not receive interference or that any particular transmission from this transmitter will be free from interference.
• If your home has specially wired alarm equipment connected to the telephone line, ensure the installation of the Communicator does not disable your alarm equipment. If you have questions about what will disable alarm equipment, consult your telephone company or a qualified installer.
• The telephone company may make changes in its facilities, equipment, operations, or procedures that could affect the operation of the equipment. If this happens, the telephone company will provide advance notice in order for you to make necessary modifications to maintain uninterrupted service.
• If the Communicator causes harm to the telephone network, the telephone company will notify you in advance that temporary discontinuance of service may be required. But if advance notice isn’t practical, the telephone company will notify the customer as soon as possible. Also, you will be advised of your right to file a complaint with the FCC if you believe it is necessary.
• Connection to party line service is subject to state tariffs. Contact the state public utility commission, public service commission or corporation commission for information.
94
LATITUDE ™ Communicator Patient Manual
• This equipment has been tested and found to comply with applicable safety portions of the following standards:
• IEC 60601-1:2005/A1:2012
• ANSI/AAMI ES60601-1:2005(R)2012
• EN 60601-1:2006 + A1:2013
• IEC 60601-1-11-2015
• CAN/CSA-C22 No. 60601-1:2014
• This equipment has been tested and found to comply with the following electromagnetic compatibility (EMC) standard: IEC 60601-1-2:2014.
• Accessory equipment connected to the analog and digital interfaces (signal inputs and signal outputs) must be certified according to the respective
IEC standards. Anyone who connects additional equipment to the signal input parts or signal output parts may configure a medical system, and is therefore responsible that the system complies with the requirements of clause 16 of IEC 60601-1:2005/
A1:2012. If in doubt, consult the technical service department or your local representative.
• This equipment has been tested and found to comply with the applicable limits for Class B medical devices in a professional health care facility or home environment to ANSI/AAMI/IEC 60601-1-
2:2014. This testing shows the device provides reasonable protection against harmful interference in a typical medical or home installation. However, there is no guarantee that interference will not occur in a particular installation.
LATITUDE ™ Communicator Patient Manual
95
Essential Performance
In accordance with clause 4.3 of IEC/EN 60601-1, the
Communicator has no performance that qualifies as essential performance.
Software Statement
The software included in this product contains copyrighted software that is licensed under the GNU
General Public License (GPL). Under the terms of the
GPL as published by the Free Software Foundation, you may obtain the complete corresponding source code from us for a period of three years after our shipment of this product.
96
LATITUDE ™ Communicator Patient Manual
Electromagnetic Emissions and
Immunity
Table 1. Guidance and manufacturer’s declaration— electromagnetic compatibility
The LATITUDE Communicator is suitable for use in a professional health care facility or home environment.
Test
Protection of radio services and other equipment
Compliance
CISPR 11
Group 1
Class B
Electromagnetic environment—guidance
The LATITUDE
Communicator uses RF energy only for its intended uses in communication with the implanted device or connectivity functions. Its
RF emissions are very low and are not likely to cause any interference in nearby electronic equipment.
Protection of the public mains network
CISPR 11 Class B
IEC 61000-3-2
IEC 61000-3-3
The LATITUDE
Communicator is suitable for use in a professional health care facility or home environment.
Electrostatic discharge
Radiated RF EM field
Proximity fields from RF wireless communications equipment
± 8 kV contact
± 2 kV, ± 4 kV,
± 8 kV, and
± 15 kV air
3 V/m from 80 MHz to
2.7 GHz
380 - 390 MHz: 27 V/m
430 - 470 MHz: 28 V/m
704 - 787 MHz: 9 V/m
800 - 960 MHz: 28 V/m
1700 - 1900 MHz: 28 V/m
2400 - 2570 MHz: 28 V/m
5100 - 5800 MHz: 9 V/m
30 A/m Rated power frequency magnetic field
Electrical fast transients/ bursts
Surges line-to-line
Surges line-to-ground
± 2 kV input AC power
± 1 kV SIP/SOP
± 0.5 kV, ± 1 kV input AC power
± 0.5 kV, ± 1 kV, ± 2 kV input AC power
LATITUDE ™ Communicator Patient Manual
97
The LATITUDE Communicator is suitable for use in a professional health care facility or home environment.
Test Compliance
Electromagnetic environment—guidance
Conducted disturbances induced by RF fields
3 V/m from 0.15 MHz to
80 MHz
6 V/m in ISM bands from
0.15 MHz to 80 MHz
The ISM bands between
0.15 MHz and 80 MHz are
6.765 MHz to 6.795 MHz
13.553 MHz to 13.567 MHz
26.957 MHz to 27.283 MHz
40.66 MHz to 40.70 MHz.
The amateur radio bands between 0.15 MHz and 80
MHz are
1.8 MHz to 2.0 MHz
3.5 MHz to 4.0 MHz
5.3 MHz to 5.4 MHz
7.0 MHz to 7.3 MHz
10.1 MHz to 10.15 MHz
14.0 MHz to 14.2 MHz
18.07 MHz to 18.17 MHz
21.0 MHz to 21.4 MHz
24.89 MHz to 24.99 MHz
28.0 MHz to 29.7 MHz
50.0 MHz to 54.0 MHz.
Voltage dips a 0% U
T
for 0.5 cycle at 0°,
45°, 90°, 135°, 180°,
225°, 270°, and 315°
0% U
70% U at 0°
for 1 cycle and
T
for 25/30 cycles
Voltage interruptions a 0% U
T
for 250/300 cycles a. Voltage dips and interruptions: U
T
is the AC mains voltage prior to application of the test level.
98
LATITUDE ™ Communicator Patient Manual
Explanation of Product and Label
Symbols
Symbol Meaning
Input from telephone jack
Output to telephone (optional)
AC/DC adapter power input
Direct current (DC)
Universal serial bus (USB) connector
Part number
Serial number
Reference number/catalog number
Non-ionizing electromagnetic radiation
IEC 60601 Class II medical equipment, protection against electrical shock
Manufacturer
Date of manufacture
Follow instructions for use
Protection against ingress of solid foreign objects and water
LATITUDE ™ Communicator Patient Manual
99
Symbol Meaning
Power indicator (applies to USB cellular adapter)
Wireless indicator (applies to Model 6295 USB cellular adapter)
Waste, Electrical, and Electronic Equipment
(WEEE) symbol. Indicates separate collection for electrical and electronic equipment (i.e., do not throw this device in the trash)
Temperature range limits
Humidity range limits
Atmospheric pressure range limits
Authorized representative in the European
Community
Australian sponsor address
(applies to distribution box)
CE mark of conformity
(applies to USB accessory adapter)
Indicates this product has passed a comprehensive testing procedure and the production plant is regularly monitored as certified by a Nationally
Recognized Testing Laboratory
Indicates this product complies with applicable
Australia radiocommunications standards
(applies to USB accessory adapter)
100
LATITUDE ™ Communicator Patient Manual
Boston Scientific Corporation
4100 Hamline Avenue North
St. Paul, MN 55112-5798 USA
Telephone: 651.582.4000
Medical Professionals: 1.800.CARDIAC (227.3422)
Patients and Families: 1.866.484.3268
www.bostonscientific.com
© 2018 Boston Scientific Corporation or its affiliates.
All rights reserved.
359371-005 en USA 2018-11
*359371-005*