Drinking Fountain Doctor Space-ette FHD7005 10 1C Installation Use And Care Manual
Publicité
Publicité
13
18
16
27, 28
45
26
FHD7005,10*1C, FHD7005,10*2C, FHD7005*3C, THAD5H*1C
Space-ette
With FLEXI-GUARD
®
Installation/Care/Use Manual
USES HFC-134A REFRIGERANT
SEE FIG. 3 7
34 (SEE FIG. 5)
SEE FIG. 4
33 (SEE PAGE 3)
30
31 & 32
43 & 44
19
17 & 20
29
15
21 14
41 & 42
FIG. 1
PAGE 1
22, 23, 24,
25, 46
97074C (Rev. B - 5/98)
FHD7005,10*1C, FHD7005,10*2C, FHD7005*3C, THAD5H*1C
FINISHED FLOOR
PISO ACABADO
PLANCHER FINI
FIG. 2
LEGEND/LEYENDA/LÉGENDE
A = RECOMMENDED WATER SUPPLY LOCATION 3/8 O.D. UNPLATED COPPER TUBE CONNECT STUB 1-1/2" (38mm) OUT FROM
WALL SHUT OFF BY OTHERS
SE RECOMIENDA UBICAR EL TUBO DE CONEXIÓN AL TUBO DE COBRE SIN CHAPAR DE 3/8" DE DIAM. EXT. A 1-1/2" (38mm)
FUERA DE LA LLAVA DE PASO EN LA PARED COLOCADA POR TERCEROS.
EMPLACEMENT RECOMMANDÉ DALIMENTATION EN EAU PAR TUBE EN CUIVRE NON PLAQUÉ DE 3/8 PO. (9,5mm) D.E.
CONNECTANT UNE TUYAUTERIE DE 1-1/2 PO. (38mm) DEPUIS LE ROBINET D'ARRET FOURNI PAR D'AUTRES.
B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4 O.D. DRAIN
UBICACIÓN RECOMENDADA PARA EL DRENAJE DE SALIDA DE AGUA, DE 1-1/4" DE DIÁMETRO.
EMPLACEMENT RECOMMANDÉ POUR LE DRAIN DE D.E. 1-1/4" DE SORTIE DEAU.
C = 1-1/4 TRAP NOT FURNISHED
PURGADOR DE 1-1/4 NO PROPORCIONADO
SIPHON 1-1/4 NON FOURNI
D = INSURE PROPER VENTILATION BY MAINTAINING 4" (102mm) (MIN.) CLEARANCE FROM CABINET LOUVERS TO WALL.
ASEGURE UNA VENTILACIÓN ADECUADA MANTENIENDO UN ESPACIO E 4" (102mm) (MÍN.) DE HOLGURA ENTRE LA REJILLA
DE VENTILACIÓN DEL MUEBLE Y LA PARED
ASSUREZ-VOUS UNE BONNE VENTILATION EN GARDANT 4" (102mm) (MIN.) ENTRE LES ÉVENTS DE LENCEINTE ET LE MUR.
E = POWER CORD 4 FEET (1219mm) LONG
CABLE ELÉCTRICO DE 4 PIE (1219mm), DE LARGO
CORDON DALIMENTATION 4' (1219mm)
97074C (Rev. B - 5/98) PAGE 2
FHD7005,10*1C, FHD7005,10*2C, FHD7005*3C, THAD5H*1C
SERVICING THE HOT CONTROL AND FUSE ASSEMBLY
1. A temperature sensing non-resetable fuse in the wire is located approximately 3" (76mm) from the thermostat.
The fuse is located under the retaining bracket (Item 3) in the groove on the heater element jacket (Item 4).
2. The thermostat must be used with a washer-spacer (Item 7) and be centered in the heater element jacket for
proper temperature control. Locate the heater element jacket about 3/4" (19mm) above the bottom of the tank.
3. The heater element jacket must be fastened VERY TIGHTLY to the tank (45+/-10 inch-lbs. of torque on the mounting
screw Item 9). Failure to TIGHTEN heater element jacket may cause rapid failure of the fuse assembly.
5
4
12
13
7
8
2
1
11
9
10
3
6
Stream height is factory set at 35 PSI. If supply pressure varies greatly from this, remove Items 1 & 2 and adjust screw on
Item 4. Clockwise adjustment will raise stream and counterclockwise adjustment will lower stream. For best adjustment, stream should hit basin approximately 6-1/2" (165mm) from bubbler.
1
2
3
4
5
BASIN
6
ITEM NO.
9
10
11
12
13
NS
7
8
5
6
3
4
1
2
PART. NO.
22111C
22112C
22113C
30980C
31386C
31428C
50787C
70606C
70607C
70640C
70659C
70683C
70793C
22588C
HOT TANK PARTS LIST
DESCRIPTION
Heater Clamping Bracket
Heater Clamping Bracket (thrd)
Retaining Bracket
Heater Element & Jacket
Tank & Tube Assy
Hot Control Assy
Washer-Spacer
Drain Plug
Screw 1/4-20 x 3.00" HSHC
Screw #8-18 x 5/16" HHTC
Belleville Washer
1/4 Union
1/4 Elbow
Hot Tank Mounting Bracket
8
9
10
11
BASIN
12
NOTE:
WHEN INSTALLING REPLACEMENT
BUBBLER AND PEDESTAL, TIGHTEN NUT
(ITEM 12) ONLY TO HOLD PARTS SNUG IN
POSITION. DO NOT OVER TIGHTEN.
FIG. 3
WIRING DIAGRAM
This Drawing is merely for illustrating the components of the electrical system.
FIG. 4
35 36
38
40
37
39
PAGE 3
FIG. 5
97074C (Rev. B - 5/98)
FHD7005,10*1C, FHD7005,10*2C, FHD7005*3C, THAD5H*1C
24b
25
26
27
28
29
29a
29b
30
22*
22a*
22b*
23
23a
23b
24
24a
43
44
45
39
40
41
42
35
36
37
38
31
32
33
34
ITEM NO.
13
14
15
9
10
11
12
7
8
5
6
3
4
1
2
16
17
18
19
20
21
46b
NS
PART NO.
194243901550
55996C
40570C
55835C
66300C
66302C
66508C
61988C
66421C
21591C
30010C
31405C
40582C
40597C
92712C
51543C
40596C
70921C
33659000
50144C
70418C
70767C
70772C
21486C
21239C
35935C
21482C
20460C
55832C
50189C
31490C
30664C
20282C
70018C
66200C
66202C
35786C
35767C
35947C
31038C
31025C
31039C
35766C
35766C
35768C
40089C
40048C
15005C
61313C
40169C
50986C
22546C
51349C
40322C
50934C
50168C
70012C
31513C
31495C
66303C
66304C
PARTS LIST 115V
DESCRIPTION
Cover
Button
Regulator Retaining Nut
Regulator
Hex Nut
Regulator Holder
Basin & Precooler Assy
Bubbler Assy
Orifice Assy
Housing Assy
Pedestal
Bubbler Locknut
Cold Control
Power Cord
Condenser (5GPH)
Condenser (10GPH)
Fan Shroud
Fan Motor
Fan Blade
Fan Bracket
Fan Blade Nut
Drier (5GPH)
Drier (10GPH)
Compressor Serv. Pak PW3HK7 (5GPH)
Compressor Serv. Pak FF7.5HBK (10GPH)
Compressor Serv. Pak EM65 (10GPH)
Overload/Relay Assy 1.350.398 (5GPH)
Overload/Relay Assy 1.350.358 (10GPH)
Overload/Relay Assy P600B/427NFBYY (10GPH)
Cover - Relay
Cover - Relay
Cover - Relay
Electrical Shield
Strainer
Precooler Assy
Tailpipe Helix
Heat Exchanger (5GPH)
Heat Exchanger (10GPH)
Heat Exchanger (10GPH)
Evaporator (5GPH)
Evaporator (10GPH)
Hot Tank Switch Bracket
Hot Tank Switch
Hot Tank Assy
Hot Valve Assy
Gooseneck
Hot Valve Kit
Handle
Shroud
Mounting Nut
Body Gasket
Grommet-Compressor
Washer-Compressor
Evaporator Retaining Clip
Evaporator Drain Plug
Cabinet-Sandalwood
Cabinet-Stainless Steel
Capacitor - Run
Front Panel-Sandalwood
Front Panel-Stainless Steel
Flow Regulator Assy NS
*REPLACE WITH SAME COMPRESSOR USED IN ORIGINAL
ASSEMBLY. NOTE: All correspondence pertaining to ELKAY water coolers or orders for repair parts MUST include Model No. and Serial No.
of cooler, name and part number of replacement part.
ITEM NO.
17
*22
23
24
33
PARTS LIST 230V-50/60Hz
PART NO.
31430C
35788C
35763C
31035C
31024C
35768C
31406C
DESCRIPTION
Fan Motor
Compressor Serv Pak (5 GPH)
Compressor Serv Pak (10 GPH)
Overload/Relay Assy (5 GPH)
Overload/Relay Assy (10 GPH)
Relay Cover (10 GPH)
Hot Tank Assy
PRINTED IN U.S.A.
97074C (Rev. B - 5/98)
www.DrinkingFountainDoctor.com 800-518-5388
PAGE 4
Publicité