USER MANUAL - Thermostatenshop

USER MANUAL - Thermostatenshop
USER MANUAL
Type OCC4/OCD4
English
Contents
Introduction................................................................................ 1
First time settings...................................................................... 1
General operation ...................................................................... 2
Back......................................................................................... 2
Exit ........................................................................................... 2
Operation mode ......................................................................... 2
Auto mode .............................................................................. 2
Manual mode .......................................................................... 2
Comfortmode ......................................................................... 2
Thermostat setup menus.......................................................... 2
4-event settings ......................................................................... 2
User settings .............................................................................. 2
Time and date ......................................................................... 2
Childlock ................................................................................ 2
Displaysettings ...................................................................... 2
4-event schedule .................................................................... 2
Energy monitor ....................................................................... 3
Engineer settings....................................................................... 3
Offset temperature................................................................... 3
Adaptive function..................................................................... 3
Application ............................................................................... 3
Temperature scale ................................................................... 3
Language ................................................................................. 3
Factory reset ............................................................................ 3
Information .............................................................................. 3
Back......................................................................................... 3
Exit ........................................................................................... 3
Error messages ......................................................................... 3
Factory settings ......................................................................... 3
Preset schedule ....................................................................... 3
Introduction
The thermostat can switch on your heating system at predetermined
times on different days of the week. For each day of the week, you
can set individual temperatures for 4 different periods, called events.
Lowering the temperature when the home is unoccupied will reduce
your energy costs without reducing comfort.
The thermostat comes with a default schedule suitable for most
homes. Unless you change the settings, the thermostat will operate
in compliance with the default schedule.
Furthermore, the thermostat features an adaptive function that
automatically changes heating period start times so as to ensure
that the required temperature is reached at the set time. After three
days the adaptive function has learned when the heating must be
switched on.
• SettheactualhourandpresstheOK button. Then set the minutes. Press OK.
• Settheactualdate:year,monthandday.Confirmthesettings
with the OK button.
The thermostat is now ready for use and will control your heating
in accordance with the pre-programmed 4-event schedule, see
Factory settings.
14:08
Power interrupter
20°C
Comfort Menu Manual
First time settings
The first time you switch the interrupter ON “I”, language, time and
date must be set. The menu will automatically guide you through the
process.
• ChooseyourlanguagewiththeUpandDownbuttonsand
confirm with OK.
Wed
Navigation buttons
1
Type OCC4/OCD4
English
General operation
The interrupter button allows you to turn the thermostat on “I” and
off “0” by sliding the button up and down. When the thermostat is
switched off “0”, the relay disengages. All settings, including time
and date, will be remembered.
The thermostat is intuitively operated using the navigation buttons.
The function of each button is indicated above the button in the
display.
1. Press the OK button to activate the 4-event settings display.
2.Choosethedaysforwhichyouwanttochangethesettings,
Mon-Fri or Sat-Sun using the up or down button. Press OK.
3. Now select the time and temperature for each daily event in the
program. Press OK and set the start time for the event concerned.
ConfirmwithOK.Setthetemperatureforthiseventandconfirm
with OK.
4. After setting the required events, select Exit in the menu to return
to the initial display.
Back
In various parts of the menus and submenus you will find the Back
menu item.
Use Back to return to the last step.
Temp
Min
5.0°C

Exit
Returns to initial dispay.
Time
25°C 40.0°C
OK 
06:00

Max
05:00
OK
08:00

User settings
Operation mode
Thethermostatfeaturesthreedifferentmodesoftemperaturecontrol:
Auto mode
SelectAutoifyouwantthetemperaturetobecontrolledautomatically via the 4-event schedule.
In the user settings menu you can change the
followingitems:
• Timeanddate
• Childlock
• Displaysettings
• 4-eventschedule
• Energymonitor
User settings

OK

Manual mode
SelectManualtocanceltheprogrammed4-eventschedule(e.g.
during holidays) and to set the required temperature manually. You
may,forexample,wanttoadjustthetemperatureto5°Cforfrost
protection while you are away.
• PressManual, confirm with OK and choose the required temperature.
Time and date
Press OK and set the actual time in hours
and minutes.
Thedatewillthenbedisplayed.Setthedate
and confirm with OK.
Time and date

OK

Child lock
Comfort mode
SelectComforttosetatemporarycomforttemperature
(so-calledpartymode)forasingleevent.
• PressComfort, confirm with OK and choose the required temperature. Then enter the required duration of comfort mode.
After the set time has elapsed, the thermostat will automatically
revert to Auto mode.
Please note: Comfort mode is a temporary manual setting that will
be automatically cancelled by the next event in the programmed
4-event schedule.
Display settings
When you wake up in the morning
Allows you to select what is shown on the
Display settings
initial display.
Time/day: Showstheactualtimeanddayat
 OK 
the top of the display.
Set temp.:Showsthecurrenttemperaturesetting.
Act. temp.:Showstheactualmeasuredtemperature.
Scr. saver:Switchesoffthedisplayafter30secondsifnobuttonis
pressed. Any subsequent press of a button reactivates
the display. The thermostat remains on and runs the
selected program.
Press the OK button to select or deselect the display options. Then
select Exit in the menu to return to the initial display and view your
chosen settings.
When you are away at work
4-event schedule
Thermostat setup menus
Themenuallowsyoutoselectthefollowingoptions:
4-event settings
Allows you to have the temperature controlled automatically in accordance with a
program of your own choice. You can select
temperature settings for four different events
duringtheday:
4-Event settings

OK

When you come home
When you go to bed at night
The thermostat is pre-programmed with a 4-event schedule for easy
and economic heating control, see Preset schedule under Factory
settings.Theschedulecanbeeasilychangedinthefollowingway:
2
Allows you to lock the thermostat settings,
Child lock
e.g. in public or other places where you do
not want the settings changed.
 OK 
Press OK and set the child lock to On using
thedownbutton.ConfirmwithOK.
The child lock can be unlocked by pressing both the Comfort and
Manual buttons simultaneously for 5 seconds.
Allows you to choose the type of weekly
4-Event schedule
4-event schedule you require.
5:2: MondaytoFridaywith4eventsand
 OK 
SaturdaytoSundaywith2events.
Typically used if you work from Monday to Friday.
6:1: MondaytoSaturdaywith4eventsandSundaywith2events.
TypicallyusedifyouworkfromMondaytoSaturday.
7:0 : MondaytoSundaywith4individualevents.Allowsyouto
choose individual programs for each of the 7 days of week.
Type OCC4/OCD4
English
Selecttherequired4-eventscheduleandconfirmwithOK.
For instructions on programming the time and temperature for the
4-event schedule, see 4-event settings.
Press OK to highlight Min temperature. Use the up or down button to select the minimum permissible temperature. Press OK and
selectthemaximumpermissibletemperature.Confirmthesettings
with OK.
Energy monitor
Allows you to view energy consumption for
Energy monitor
thepast2days,30daysor365days.
Press OK for the chosen period. The value
 OK 
inpercent(%)showstherelativeamountof
time the heating has been on. The following figure is the cost for the
selected period. To ensure correct calculation, check the settings for
currency, price per kWh and load.
Currency:PressOK and chose the required currency.
ConfirmwithOK.
Cost/unit:PressOK and set the actual cost of electricity.
The cost must be entered per kWh. Press OK.
Load:
PressOK and enter the connected heating power.
Thevaluemustbeinwatt(W).PressOK.
Leave the menu by pressing Exit.
Language
Allows the language used on the display to
be changed.
Press OK and select the required language.
ConfirmwithOK.

OK

Factory reset
Allows factory settings to be restored. Your
personal settings will be lost, see Factory
settings.
Press OK and choose Reset in the menu.
ConfirmwithOK.
Information
Displaysthethermostatsoftwareversion.
Engineer settings
Language
Factory reset

OK

Information

OK

TheEngineersettingsmenucontainsthefollowingoptions:
• Offsettemperature
• Adaptivefunction
• Application
• Temperaturescale
• Language
• Factoryreset
• Information
Back
Offset temperature
If a fault or error occurs, the thermostat will display an error code as
follows:
E0:Internalfailure.Thethermostatisdefective.Replacethermostat.
E1:Internalsensordefectiveorshort-circuited.
E2:Externalsensordefectiveorshort-circuited.
E5:Internaloverheating.Inspecttheinstallation.
If the actual measured temperature does not
corresponding to the thermostat value, you
can adjust the thermostat by offsetting the
temperature.
Press OK and enter the value of the measuredtemperature.ConfirmwithOK.
In various parts of the menus and submenus you will find the Back
menu item.
Use Back to return to the last step.
Exit
Returns to initial dispay.
Error messages
Offset temp.

OK

Factory settings
Adaptive function
Ensures that the required temperature has
Adaptive function
already been reached when you get up in the
morning or come home from work. After just
 OK 
a few days, the adaptive function will have
automatically calculated when the heating must be turned on.
Press OK and set the function to On.ConfirmwithOK.
Application
Setthetypeofregulationused.
Application
Thereare3options:
Floor reg. : The thermostat regulates floor
 OK 
temperature only. A floor sensor must be connected.
Room reg. : The thermostat regulates room temperature only.
Room/limit : The thermostat regulates room temperature with min.
and max. limits for floor temperature. A floor sensor
must be connected.
Regulator : The thermostat functions as a simple regulator and no
sensors are used. The setting is a percentage.
Press OKandselecttherequiredapplication.ConfirmwithOK.
Preset schedule
Day 1-5
Event
Time
With floor sensor With room sensor
Day
06:00-08:00
25°C
20°C
Out
08:00-16:00
20°C
15°C
Home
16:00-22:30
25°C
21°C
Night
22:30-06:00
20°C
15°C
Event
Time
With floor sensor With room sensor
Day
08:00-23:00
25°C
21°C
Night
23:00-08:00
20°C
15°C
Day 6-7
Temperature scale
Allows you to set the temperature range
within which the thermostat can be set. It is
then only possible to set a temperature within
this range in auto, comfort and manual mode.
Temp scale

OK

3
Was this manual useful for you? yes no