Graham Corporation Liquid Ring Pump 2 Series Installation, Operation & Maintenance Manual
Graham Corporation Liquid Ring Pump 2 Series
The Graham Corporation Liquid Ring Pump 2 Series combines a simple design with rugged construction to provide dependable, long-lasting vacuum or pressure service across a wide range of applications, including:
- Chemical Processing
- Distillation
- Filtration
- Crystallization
- Degassing
- Priming of centrifugal pumps
Features:
- Single-stage - up to 29.9" Hg vacuum (98 kPa abs)
- Two-stage - up to 26.5" Hg vacuum (3.2 kPa abs)
- Discharge pressure to 125 psig (8.6 barg)
- Flows to 4000 ACFM (10,000 m³/hr)
- Materials of construction include cast iron, ductile iron, 316 stainless steel, and Alloy C
Advertisement
Advertisement
Graham Corporation
Table of Contents
Section 1 - General Information ................................................................................................... 3
1.1 Introduction...................................................................................................................................... 3
1.2 General Description and Principle of Operation .............................................................................. 4
1.3 Description of Pump Model Codes .................................................................................................. 5
Section 2 - Installation Instructions .............................................................................................. 6
2.1 Handling........................................................................................................................................... 6
2.2 Preservation...................................................................................................................................... 6
2.3 Mounting.......................................................................................................................................... 6
2.4 Installation........................................................................................................................................ 6
2.5 Coupling Alignment......................................................................................................................... 7
2.6 Belt Drives ....................................................................................................................................... 8
2.7 Service Liquid Piping Arrangements ............................................................................................... 8
2.8 Shaft Seal Coolant Piping Arrangement ........................................................................................ 11
2.9 Piping Requirements ...................................................................................................................... 11
2.10 Electrical Requirements ............................................................................................................... 12
Section 3 - Operating Instructions .............................................................................................. 12
3.1 Start-up Procedures ........................................................................................................................ 12
3.2 Pump Packing Adjustment............................................................................................................. 13
3.3 Service Liquid Requirements......................................................................................................... 14
3.4 Cavitation ....................................................................................................................................... 15
3.5 Shut-Down Procedure .................................................................................................................... 16
Section 4 - Accessory Items........................................................................................................ 16
4.1 Accessories..................................................................................................................................... 16
Section 5 - Maintenance.............................................................................................................. 19
5.1 Performance ................................................................................................................................... 19
5.2 Pump Estimated Weights ............................................................................................................... 19
5.3 Shaft Bearings ................................................................................................................................ 19
5.4 Gland Packings .............................................................................................................................. 19
5.5 Mechanical Seals............................................................................................................................ 19
5.6 Storage ........................................................................................................................................... 20
5.7 Removal from storage.................................................................................................................... 20
5.8 Troubleshooting Chart ................................................................................................................... 21
Section 6 - Rebuild Instructions.................................................................................................. 22
6.1 General ........................................................................................................................................... 22
6.2 Impeller End Clearances ................................................................................................................ 22
6.3 Tie Rod Torque Values .................................................................................................................. 24
6.4 Bearing Data .................................................................................................................................. 24
Section 7 - Warranty ................................................................................................................... 25
Appendix A- Material Safety Data Sheets.................................................................................. 26
Appendix B- Return Material Authorization Form .................................................................... 29
Appendix C- Pump Information ................................................................................................. 30
Appendix D- Pump Weights....................................................................................................... 31
Graham Corporation
Section 1 - General Information
1.1 Introduction
This manual will provide assistance in the installation, operation, and maintenance of your
Graham Liquid Ring Pump. Please read this manual completely prior to operating your Liquid
Ring Pump. If you need to contact the Pump Service Department for assistance, please have available the pump serial number and model number. The Pump Service Department may be reached by contacting Graham Corporation in Batavia, NY by phone (585) 343-2216, Fax (585)
343-1097, or e-mail at [email protected]
. Refer to the Graham web site at www.graham-mfg.com
for other information on our Liquid Ring Pumps.
Graham has an extensive stock of spare parts and replacement pumps. Stocked parts and pumps can be shipped from our warehouse in Batavia, NY by a carrier of your choice.
For your convenience, use our toll free number (1-800-828-8150) only when ordering spare parts and replacement pumps. Please have the model number, serial number and part number of the items required when placing an order. Refer to Graham web site www.graham-mfg.com
for
Liquid Ring Vacuum Pump spare parts information. Normal business hours are 8:00 a.m. to 5:00 p.m. (E.S.T.), Monday through Friday.
Factory rebuilding service is available for pumps returned to our factory in Batavia, New York.
Before a pump is returned to the factory for repairs, please drain and flush the pump and include a Material Safety Data Sheet (MSDS) for the process in which the pump was used. A Return
Material Authorization (RMA) Number, issued by Graham, is required before returning a pump.
Refer to our web site for this form or contact Graham for this information. Field Service
Technicians are also available for travel to the jobsite for troubleshooting and repair or rebuilding of pumps. Contact Graham for service rates.
This document and the information contained herein are the property of Graham Corporation and must not be copied, in whole or in part, nor used for manufacture or otherwise disclosed without the prior written consent of the company. Information contained herein may, from time to time, be revised and/or updated.
Copyright Graham Corporation 2006
3
Graham Corporation
1.2 General Description and Principle of Operation
Graham Vacuum Pumps and Compressors are of the liquid ring type. Single and two stage pumps are available in a wide range of sizes and materials. These options are listed in the
Graham Sales Bulletin available on our web site. The major component of the Graham pump is a multi-bladed rotating assembly positioned eccentrically in a cylindrical casing. (See Figure 1)
This assembly is driven by an external source, normally an electric motor. Service liquid
(usually water) is introduced into the pump. As the impeller rotates, centrifugal force creates a liquid ring which is concentric to the casing. At the inlet, the area between the impeller blades
(buckets) increases in size, drawing gas in. As the impeller continues to rotate toward the discharge, the impeller bucket area decreases in size, compressing the gas. This gas, along with the liquid from the pump, is discharged through the outlet nozzle. The service liquid is separated from the gas and cooled for reuse in the pump or sent to a drain. In addition to being the compressing medium, the liquid ring performs two other important functions:
1) It absorbs the heat generated by compression, friction, and condensation of the incoming vapor.
2) It absorbs and washes out any process contaminants entrained in the gas.
A continuous supply of service liquid is necessary to limit the temperature rise in the pump caused by the heat of compression, friction, and condensation. Any excessive rise in temperature will have a detrimental effect on performance, reducing the capacity and degree of vacuum attainable. Installation schematics for the supply of the service liquid and for the separation of the gas and liquid discharged from the pump are shown in Section 2.
Gas and
Liquid Outlet
Gas
Inlet
Rotation
Liquid Ring
Discharge Port
Gas
Impeller
Shaft
Suction Port
F IGURE 1
4
Graham Corporation
Service liquid quantities are a function of the particular model and the intended application.
Check the data sheet for your specific pump model or see Table 1 of Section 3 which lists typical service liquid requirements for Graham Model Pumps.
The normal operating ranges of Liquid Ring Pumps when using water at 59 º F
(15 ºC) for the service liquid are:
Single Stage Pumps
Two Stage Pumps
Two Stage Pumps w/Air Ejector
Single Stage Compressors dependent on model, down to 25 mmHgA down to 25 mmHgA down to 3 mmHgA
20 psi (1.4 bar) max. differential
Two Stage Compressors 30 psi (2.1 bar) max. differential
The standard materials of construction are suitable for handling air and other non-corrosive gases, while using water as the service liquid. Other materials can be supplied for special applications.
1.3 Description of Pump Model Codes
Each pump is designated by a model code which describes the materials of construction, size, type of shaft seals, and any special features. An example of a typical pump is shown below.
Number of Stages
Frame Size
Series 2 Design
Size
C-faced mounting option
(not available on all models)
2 PV 42120 / 10 / DD / L
Vacuum Pump = PV
Material
Code
Design Code
Note: Graham Pump Models LXP30 & LXP55 are replacements for models 2PV31020 and
2PV31040 respectively.
5
Graham Corporation
Section 2 - Installation Instructions
2.1 Handling
Carefully unpack the pump. Bare pumps may be lifted with a sling placed around the bearing housings or under the flanges.
Lift pump-motor assemblies by the baseplate only. Do not attach slings or hooks to the motor or the pump as this can cause misalignment. Do not attempt to run the pump until the installation work is complete.
CAUTION: DO NOT RUN THE PUMP WITHOUT SERVICE LIQUID AND SHAFT
2.2 Preservation
Cast Iron and Steel pumps are protected internally with a preservative solution applied at the factory before shipping. The preservative solution should be flushed from the pump prior to use.
An MSDS form is included in the back of this manual (Appendix A).
The preservative solution is petroleum based and must be disposed of in accordance with all Local, State, and Federal regulations.
2.3 Mounting
Before operation, the pump package should be carefully set, leveled, and securely bolted in place. It is recommended that shims and grout be used as necessary under all structural members of the base.
Graham vacuum pumps supplied with an adapter for mounting a NEMA C-faced motor should be bolted to a floor, a cement pad or an existing framework. Support bracket located under motor lantern should contact but not be anchored to the floor or mounting base.
Baseplates supplied with a pump and drive motor mounted at the factory should be leveled, shimmed as required, and firmly anchored.
2.4 Installation
All piping to the pump should be adequately supported to eliminate any stress at the pump connections. All piping joints should be tested for leaks prior to start-up. A temporary start-up strainer in the process inlet piping may be used to keep large contaminates from entering the pump at start-up.
6
Graham Corporation
Install the piping for the service liquid and process, as required. Refer to Section 2.7 for details.
The location of the installation or the storage of the pump should be in an area that will not subject the pump to freezing.
Verify the pump’s rotation direction by checking the arrow on the shaft end casing. Refer to
Section 2.10 concerning the electrical requirements.
CAUTION: TO PREVENT PERSONAL INJURY, DO NOT OPERATE THE PUMP
WITHOUT PROPERLY GUARDING THE DRIVE COUPLING(S).
Pumps supplied from the factory packaged with a motor on a baseplate have had the shafts aligned prior to shipment. This ensures that alignment can be done in the field. It is required that the shaft alignment be rechecked after mounting on a level foundation and prior to start-up.
When a gear reducer is supplied between the pump and motor, they are aligned at the factory and must be realigned after installation. The gear reducer should be aligned to the pump first and then the motor should be aligned to the gear reducer.
For smoother operation and longer life of the coupled equipment, the following maximum misalignment tolerances are recommended:
The maximum allowable parallel shaft misalignment for standard couplings is ±0.002
" (0.05 mm) and for spacer couplings is ±0.001
" per inch (0.025 per mm) of spacer length.
±0.002
±0.001
"
"
or
x L
L
The maximum allowable angular shaft misalignment is ±0.0005
" per inch
(0.013 per mm) of coupling diameter.
D
±0.0005
" x D
Pumps provided with a C-faced mounted motor do not require alignment, however, the coupling should be checked prior to start-up.
7
Graham Corporation
CAUTION: TO PREVENT PERSONAL INJURY, DO NOT OPERATE THE PUMP
WITHOUT PROPERLY GUARDING THE DRIVE BELTS.
When pumps are supplied with belt drives, follow the belt manufacturer’s instructions to set the tension.
2.7 Service Liquid Piping Arrangements
The operating principle of a liquid ring pump depends on a continuous supply of clean service liquid, which is normally water. The liquid enters the pump through a connection on the casing and is discharged from the pump along with the gas. There are two basic piping arrangements that can be used for liquid ring pump applications. A once-through method with no recovery of the service liquid and a recirculation method which re-uses the service liquid.
Both of these arrangements have four basic elements:
1) A supply of service liquid.
2) A means to control flow of service liquid.
3) A means of stopping the flow of service liquid when the pump is off.
4) A means of separating the gas / liquid exhaust mixture.
It is recommended to use a strainer to ensure that foreign matter does not enter the pump with the service liquid supply or make-up source. See Diagrams 1 and 2 for the proper piping arrangement scheme.
CAUTION: COMPLETE ALL PIPING INSTALLATION AND MAKE SURE A
SUPPLY OF SERVICE LIQUID IS AVAILABLE BEFORE
STARTING THE PUMP.
8
Graham Corporation
A) Typical Installation of Once Through with No Recovery
The service liquid is piped directly from a supply source to the pump. The liquid is separated from the gas in the separator and discharged to a drain. No recirculation nor recovery takes place. This is the most basic arrangement and can be used when service liquid conservation or contamination is not a concern. A solenoid operated valve provides for flow of the liquid simultaneously with the pump/motor operation. When the motor stops, the valve closes to prevent the pump casing from filling with fluid. The by-pass valve is used to pre-fill the pump at initial start-up only. It also can be used should the solenoid fail. When a manual valve is used, it must be opened immediately after starting the motor and closed immediately before turning the motor off.
A B
C D Gas
Outlet
F
Process
Inlet
Service
Liquid Inlet
G
E
H J
S
K L M
Liquid
Drain
A. Inlet Check Valve
B. Pressure Gauge (vacuum gauge for vacuum service or compound gauge for compressor service)
C.
D.
Vacuum Relief Valve (not required for compressor service)
Discharge Separator
G. Strainer
H.
J.
K.
L.
M.
Regulating Valve
Solenoid Valve
Compound Gauge
Liquid Ring Pump
Trap (required if discharge pressure is above atmospheric pressure)
O NCE T HROUGH WITH N O R ECOVERY
D IAGRAM 1
9
Graham Corporation
B) Typical Installation of Closed Loop with Total Recovery
This arrangement provides for the total recirculation of the service liquid. A heat exchanger is added to the system to remove the heat of compression, friction, and condensation from the service liquid before it is re-introduced to the pump.
The service liquid level in the separator of a total recovery system should be at, or slightly below, the centerline of the pump shaft. A provision should be made for a high level overflow.
This will prevent starting the pump while it is full of liquid, which will damage the pump or overload the motor.
B
C D E
A
Gas
Outlet
Process
Inlet
F G H
LG
Cooling
Liquid Inlet
J K
L
Cooling
Liquid
Drain Make-up
Overflow
M N
A. Inlet Check Valve
B. Pressure Gauge (vacuum gauge for vacuum service or compound gauge for compressor service)
G. Shut-off or Throttling Valve
H. Compound Gauge
J.
K.
Liquid Ring Pump
Recirculation Pump (if required)
C. Vacuum Relief Valve (not required for compressor service)
D. Level Gauge
E. Discharge Separator
F. Service Liquid Cooler
L. Trap or Loop Seal (required if discharge pressure is above atmospheric pressure)
M. Drain Valve
N. Make-Up Valve
C LOSED L OOP -T OTAL R ECOVERY
D IAGRAM 2
10
Graham Corporation
C) Draining Before Start-Up
CAUTION: DO NOT START THE PUMP WITH THE CASING FULL OF LIQUID.
A Liquid Ring Pump should not be started with the casing full of liquid. Damage to the impeller(s) or the shaft will result. The normal liquid level should be no higher than the shaft centerline. The pump may be started with a low liquid level as long as a supply of service liquid is available immediately after start-up.
2.8 Shaft Seal Coolant Piping Arrangement
The Graham model Liquid Ring Vacuum Pumps incorporate internally flushed mechanical seals as a standard. Models that have been supplied fitted with special seal arrangements may require external flushing. Consult the factory for details.
A) Suction and Discharge Piping
The suction and discharge flanges on the pump are arranged vertically and are marked with arrows on the pump casing. The suction and discharge piping should be the same nominal size as the pump flanges. The elevation of the discharge separator above the discharge flange should be limited to an elbow turning horizontally.
If necessary, a discharge leg can be used with a maximum of 24 inches (610 mm) above the pump discharge flange. Too high an elevation in this line will cause excessive backpressure on the pump, overload the motor, and reduce the pump capacity.
Remove the protective coverings from the pump openings just before attaching the piping. Check that all foreign matter such as weld slag, nuts, bolts, rags, and dirt has been cleaned out of the piping before connecting to the pump. The piping flanges must fit easily and without strain on the pump flanges and the flange bolt holes must be in alignment. The flange gaskets must not protrude into the bore of the piping or pump flanges. All piping must be supported independently on each side of the pump without transmitting any strain to the pump casing. A temporary suction strainer fitted at the suction inlet is recommended during the first 100 hours of operation.
B) Service Liquid Piping
In a once-through arrangement, the nominal pipe size should be the same size as the service liquid connection. In a total recirculation package with no recirculation pump, use one nominal pipe size larger than the service liquid connection of the pump. Also, use the least number of fittings to minimize the pressure drop. When a recirculation pump is used, the piping should be the same size as the service liquid connection.
11
Graham Corporation
All electrical wiring and installation must comply with local safety codes. After the electrical work is complete, the motor should be jogged to check for proper rotation. First, turn the pump by hand to see that it rotates freely. On packed gland pumps, it may be necessary to loosen the gland packing rings (see Section 3.2) to allow the shaft to turn easily. The direction of rotation is marked on the pump. Second, jog the motor momentarily to check the rotation. It is recommended to use a non-reversing motor controller to prevent the pump from turning in the wrong direction.
Section 3 - Operating Instructions
3.1 Start-up Procedures
Read all instructions before proceeding.
1) Turn the shaft manually to ensure it rotates freely. If the pump is binding or seized, refer to the troubleshooting chart in Section 5.
2) Fill the pump with service fluid to the shaft centerline, but do not overfill.
CAUTION: DO NOT RUN THE PUMP WITHOUT SERVICE LIQUID
AND SHAFT SEAL FLUID.
3) The normal service liquid level should be no higher than the shaft centerline. The pump may be started with a low service liquid level as long as a supply is available immediately after start-up.
4) Open any valves in the suction and discharge lines.
5) Confirm the pump rotation with the arrow on the casing by jogging the motor.
6) Start the motor, ensure service liquid supply, and set regulating valve, when used, for optimum pump performance. Open and adjust the shaft seal cooling liquid valve, when used.
12
Graham Corporation
3.2 Pump Packing Adjustment (where applicable)
The packing adjustment nuts should be loosened before running to prevent damage to the shaft.
With the gland follower loosened, the liquid pressure in the glands will force the packing rings against the gland follower. The pump can be run for several hours in this manner. Tighten the gland follower to allow the cooling fluid to drop from the gland at a rate of about 20 drops per minute from each end while the pump is running at a steady state.
Gland Packing
Packing Adjustment Nuts
O NE END OF PUMP SHOWN
Pump Shaft
Gland Follower
13
Graham Corporation
3.3 Service Liquid Requirements
A) Flow Rates
Sealant water flow rate will vary based on what conditions the liquid ring pump is operating under. Table 1 provides information for most operating conditions. Sealant flow is considered acceptable when the required vacuum level is at design, motor amps are at design, and cavitation is not evident during pump operation.
Graham Liquid Ring Pump Sealant Water Flow Rates
Pump Frame Size Sealant Water Flowrate
USGPM
Sealant Water Flowrate m3/hr
LX Series
Series 3
Series 4
Series 5
Series 6
Series 7
Series 8
Series 9
Series 10
Series 11
Series 12
Series 13
Range 0.5 to 2.0
Nominal 1.0
Range 1.5 to 3.0
Nominal 2.0
Range 2.0 to 4.0
Nominal 3.0
Range 5.0 to 11.0
Nominal 9.0
Range 8.0 to 17.0
Nominal 12.0
Range 25.0 to 40.0
Nominal 30.0
Range 45.0 to 80.0
Nominal 60.0
Range 50.0 to 70.0
Nominal 65.0
Range 50.0 to 85.0
Nominal 75.0
Range 70.0 to 110.0
Nominal 100.0
Range 100.0 to 170.0
Nominal 150.0
Range 150.0 to 230.0
Nominal 210.0
Range 0.1 to 0.5
Nominal 0.3
Range 0.3 to 0.7
Nominal 0.5
Range 0.5 to 0.9
Nominal 0.7
Range 1.1 to 2.5
Nominal 2.0
Range 1.8 to 3.8
Nominal 2.7
Range 5.7 to 9.0
Nominal 6.8
Range 10.2 to 18.1
Nominal 13.6
Range 11.3 to 15.9
Nominal 14.8
Range 11.3 to 19.3
Nominal 17.0
Range 15.9 to 25.0
Nominal 22.7
Range 22.7 to 38.6
Nominal 34.0
Range 34.0 to 52.2
Nominal 47.7
T ABLE 1
14
Graham Corporation
B) Flow Control
If a flow device is not used to measure the service liquid quantity to the pump, a regulating valve and compound gauge in the service liquid line can be used to approximate the flowrate. For pump operating pressures between atmospheric and 400 mmHgA, the reading on the compound gauge should be in the range of 2" HgV to 5 psig (709 mmHgA to 0.35 barg). For operating pressures below 400 mmHgA, the compound gauge reading should be in the range of 15" HgV to 2 psig (379 mmHgA to 0.14 barg). This method is only an approximation of the service liquid quantity. The actual operating conditions will dictate the amount of sealant liquid required and also the compound gauge reading.
Another procedure used to establish minimum service liquid flow is to slowly reduce the flow until the suction pressure fluctuates from the desired level. Gradually increase the flow until the suction pressure stabilizes. This flow setting can be used as long as the temperature rise through the pump remains reasonable (e.g., 10-20 ºF maximum for water sealant) and all other operating conditions remain constant.
C) Hard Water
If hard water is used as the service liquid, scale deposits caused by the precipitation of mineral salts will occur. This will vary with the temperature of the water. Scale deposits on the internal surfaces of the pump will cause an increase of the operating horsepower, wear on moving parts, and may cause the pump to seize.
If the hardness of the water is excessive, consider using a water softening treatment or a descaling compound. If no alternatives are possible, it may be necessary to periodically dismantle the pump to strip off the encrusted salts.
3.4 Cavitation
Cavitation is identified by a characteristic metallic or grinding noise inside the pump. It is caused when the pump suction pressure is too close to the vapor pressure of the service liquid. If the service liquid temperature inside the pump rises such that the vapor pressure closely approaches the total suction pressure of the pump, cavitation will occur.
15
Graham Corporation
When cavitation takes place, vapor bubbles form and collapse within the liquid ring. This will damage the surfaces of the impeller, side plates, and casing. The cavitation shock force causes damage by tearing away metal particles and deforming soft materials. The damage can be more severe in a corrosive situation.
Cavitation is prevented by bleeding air into the pump to raise the suction pressure. Vacuum relief valves can be fitted in the suction piping for this purpose.
If the problem is not caused by a low flow of non-condensable gases, the service liquid temperature should be checked. With the proper temperature, the operating vacuum can be increased. Ultimately, the vacuum at which the pump can be operated is governed by the vapor pressure of the service liquid inside the pump.
3.5 Shut-Down Procedures
1) Shut off the service liquid supply, and if used, the shaft seal coolant, and immediately stop the drive motor.
2) If necessary, close all suction and discharge valves.
3) If necessary, drain the pump to protect it from freezing by removing all drain plugs by draining.
4) Disconnect power from the motor if maintenance is to be performed.
Section 4 - Accessory Items
4.1 Accessories
There are many accessory items associated with Liquid Ring Vacuum Pumps and Compressors.
They can be supplied by Graham and shipped from the factory or can be supplied by others and installed in the field. The particular requirements, mode of operation, and type of control scheme desired dictate the necessity of various items. The following is a list of common accessories.
Inlet Check Valve Used to prevent a back flow of gas into the process when the pump is stopped. Check valves are normally installed in a horizontal line. An elbow can be provided to adapt the vertical pump inlet to accept a horizontal check valve.
Vacuum Relief Valve Used to protect the pump from cavitation and control the pump suction pressure. When the pump capacity exceeds the system’s flow requirements at a pre-determined level, the valve will open and bleed in atmospheric air or process gas.
16
Graham Corporation
Flexible Connector Used to compensate for minor misalignment or expansion between the pump connections and the process piping.
Vacuum Gauge Used to indicate vacuum at the pump inlet. Normally mounted directly ahead of the pump suction.
Shut-off Valve
Strainer
Flow Regulator
Used to manually stop the flow of service liquid to the pump.
Used to filter out solid particles that will damage the pump.
Used to control the service liquid flow rate to the pump.
A manual valve, a fixed orifice, or a flexible element orifice may be used depending on the application.
Compound Gauge Used to indicate pressure in the service liquid piping.
Discharge Separator Used to separate the service liquid from the discharged gas as it comes out of the pump. The liquid can be piped to a drain or recovered for re-use.
Solenoid Valve Used to automatically stop or start the flow of service liquid to the pump. Normally interlocked to the pump motor.
By-pass Valve Used to initially fill the pump with service liquid or for bypass in case the solenoid coil fails.
Recirculation Pump Used to circulate the service liquid recovered from the discharge separator in some total recovery systems.
Heat Exchanger
Atmospheric
Air Ejector
Used to remove heat from the recirculated service liquid.
Used to provide a suction pressure lower than the pump is capable of when operating alone. It may be added to a two stage pump to provide an inlet pressure as low as 3 mm HgA. The operation of the air ejector is similar to that of a steam ejector.
Atmospheric air or recycled gas from the discharge separator is used as the motive force for compressing the process gas from the system design pressure up to the inlet pressure of the pump. To enhance pumping capacity at a higher suction pressure, an optional motive air shut-off valve or by-pass valve can be added.
(See Figure 2)
17
Graham Corporation
Atmospheric
Air Inlet
Atmospheric
Air Ejector
Discharge
Optional
Shut-off
Valve
Liquid Ring
Vacuum Pump
Optional
By-pass
Valve
Typical Atmospheric Air Ejector
Process Inlet
F IGURE 2
18
Graham Corporation
Section 5 - Maintenance
5.1 Performance
Optimum performance and long service life are dependent upon good maintenance procedures and periodic inspections. When preparing to dismantle a pump, make provisions for the safe handling of heavy parts.
5.2 Pump Estimated Weights
Refer to table in Appendix D for estimated pump weights.
The standard bearings used in Graham model pumps are rated for a L10h life of 80,000 hours.
The temperature of the bearings should not exceed 140 o F (60 o C). Overheating may be due to excess grease, misalignment of the shafts, or a bad bearing. Refer to Appendix C for bearing information.
Some large Graham pump models are available with gland packing. Refer to Appendix C for gland packing information.
Adjustment: If the glands leak air into the pump or excessive leakage of service liquid occurs, tighten the gland follower slightly. (See Section 3.2) If further tightening becomes impossible, replace the packing.
Graham pumps are fitted with single acting mechanical shaft seals manufactured to DIN24960 standard. They should be reconditioned or replaced when worn, scratched, cracked, or when the rotating segment no longer grips the shaft. Seal elastomers should also be inspected and replaced as appropriate. Refer to Appendix C for seal size information.
As an option, Graham model pumps are available with double mechanical seals as well as single and double cartridge mechanical seals. The more elaborate seals of this style are utilized when the pump is used in severe, corrosive or hazardous service. External seal flushing arrangements are normally required for this type of service, as well as API Seal Flush plans and vessels using barrier fluids. Contact the factory for specific information.
19
Graham Corporation
5.6 Storage
If a pump is to be out of service, it should be protected internally from rusting by using a rust inhibitor. The pump should be drained completely by removing all the lower plugs. Install the plugs and fill with Oakite Ryconox 20M (or equal) preservative solution. Remove the manifold(s) and spray the insides with preservative. Rotate the pump manually to circulate the solution. Drain the pump to below the shaft centerline and replace the manifold(s). This procedure may be disregarded for pumps made of stainless steel, bronze, Monel, or other corrosion resistant materials.
Seal the flanged openings to prevent foreign material from entering the pump.
The pump shaft should be rotated each week to distribute the preservative and to prevent flat spots on the bearings. Document the time, date, and by whom this procedure was performed.
The manifold(s) should be re-sprayed monthly and the pump checked to see that the preservative is maintained. This will protect the pump for up to 12 months.
Pumps stored at low temperatures may need to be protected from freezing either by draining completely or by using an anti-freeze solution.
Pumps with V-belt drives should have the belts loosened to relieve the belt tension during storage. Do not store near running electric motors as ozone produced is detrimental to the rubber in the belts.
5.7 Removal from storage
The pump should be drained and flushed if necessary to remove the preservative solution. Refer to
Section 3.1 of this manual for the recommended start-up procedure.
CAUTION: THE OAKITE PRESERVATIVE SOLUTION IS PETROLEUM
BASED AND MUST BE DISPOSED OF IN ACCORDANCE WITH
ALL LOCAL, STATE, AND FEDERAL REGULATIONS.
A MSDS form can be found on the Graham web site at www.graham-mfg.com
20
Graham Corporation
Problem Cause
Reduced
Capacity
•
•
•
•
•
Speed too low
Leak in suction line
Service liquid temperature too high
Insufficient or excess service liquid
Excessive back pressure
Excessive
Noise
•
•
•
•
Excessive or insufficient service liquid
Shaft misalignment
Defective bearing
Cavitation
High Power
Consumption
•
•
•
•
•
•
•
Back pressure
Excessive service liquid
Shaft misalignment
Excessive back pressure
Defective bearing
Gland follower too tight
Improperly mounted pump
•
High temperature process load
Overheating
•
Service liquid temperature too high
•
Insufficient service liquid
•
•
•
Shaft misalignment
Defective bearing
Gland ring too tight
Vibration
•
•
•
Shaft misaligned
Pump or baseplate not properly anchored
Defective bearing
Improperly mounted pump
•
Cavitation
•
•
•
Back pressure
Excessive service liquid
Excessive
Gland
Leakage
Abnormal
Bearing Wear or Failure
Shaft Will Not
Turn or
Partially
Seizes
•
•
•
•
•
•
•
•
•
•
Worn packing
Loose gland
Gland coolant pressure too high
Shaft misalignment
Piping load on pump flange
Mechanical seal leakage
Shaft flinger missing
Scale build-up
Foreign object in pump
Piping load on pump flange
Improperly mounted pump
•
•
Soft foot
T ABLE 3
Solution
•
•
•
•
•
Check power supply and transmission
Repair
Check coolant flow & heat exchanger
Provide correct flow rate
Eliminate cause of back pressure
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Adjust flow rate
Realign shafts
Replace bearing
Open attenuation valve or adjust vacuum relief valve
Eliminate cause of back pressure
Reduce flow rate
Realign shafts
Eliminate cause of back pressure
Replace bearing
Loosen gland follower
Make sure surface is level and all feet touch the surface, shim if necessary.
Check conditions upstream of pump
Check coolant flow & heat exchanger
Provide correct flow rate
Realign shafts
Replace bearing
Loosen gland ring, check packing coolant flow
Realign shafts
Anchor
Replace bearing
Make sure surface is level and all feet touch the surface, shim if necessary.
Open attenuation valve or adjust vacuum relief valve
Eliminate cause of back pressure
Provide correct flow rate
•
•
•
•
•
•
•
•
•
•
•
•
Replace packing
Tighten gland follower
Reduce pressure
Realign shafts
Support connecting pipe work
Replace seals
Replace flinger
Descale pump
Remove foreign object
Support connecting pipe work
Make sure surface is level and all feet touch the surface, shim if necessary.
Correct pump/motor mounting
21
Graham Corporation
Section 6 – Rebuild Information
6.1 General
Graham Corporation has a fully staffed Service Department available to repair or rebuild your liquid ring vacuum pump. Prior to returning any equipment for service, a RMA number (Return
Material Authorization Number) must be obtained. Go to www.graham-mfg.com for information. All instructions on the form must be followed prior to returning the unit to
Graham.
Complete disassembly of the pump is seldom necessary and it only may need to be disassembled to the point required for repair or service. Before any servicing takes place, it is recommended that you obtain the necessary factory parts. To make the selection process complete, Graham offers a "Pump Rebuild Kit" for most pump models. The items in this kit will enable you to replace the normal wear items in the pump, such as the mechanical seals, lip seals, bearings and gaskets. The kit also includes the necessary bearing and impeller locknuts, as well as an impeller spacer. Consult Graham web site for details.
6.2 Impeller End Clearances
Refer to Appendix C for pump internal clearance information. These values are for each side of the impeller in each stage. These clearances are extremely important for optimum pump performance. Also refer to the dismantling and reassembly procedures that were provided with the documentation sent with your pump.
A) Gasketed Pumps
The critical impeller end clearance locations and typical gasket locations are shown in Figures 3 and 4. The gaskets between the impeller casings and end plates determine the impeller end clearances. Check and record the thickness and quantity of these gaskets at each joint when dismantling. The gaskets may be held in place with grease during re-assembly.
Do not use joint sealing compound to replace a gasket, as the clearances in the pump will be affected.
22
Graham Corporation
Gaskets
*
Gasket/
Compound
Single Stage
F IGURE 3
*
Gasket/
Compound
*
*
Gaskets
*
Gasket/
Compound
Two Stage
F IGURE
4
*
Gasket/
Compound
23
Graham Corporation
B) Non-Gasketed Pumps
Certain Graham pumps do not require gaskets, but use a joint sealing compound between the impeller casings and the end plates. They are machined to accommodate the same impeller end clearances as a gasketed pump.
6.3 Tie Rod Torque Values
Refer to Appendix C for bolting torque values.
Refer to Appendix C for pump bearing information.
24
Graham Corporation
Section 7 - Warranty
THE FOLLOWING IS IN LIEU OF ALL WARRANTIES OF GRAHAM EXPRESSED OR
IMPLIED AND ALL IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO ANY
IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE, AND/OR ANY OTHER OBLIGATION ON THE PART OF GRAHAM ARE
HEREBY EXCLUDED:
Graham, except as otherwise provided, warrants goods of its own manufacture against faulty workmanship or the use of defective materials, under normal use and service, and that such goods will conform to mutually agreed upon written specifications, drawings, and is guaranteed to meet specified performance requirements, for a period of twelve (12) months from date of shipment of the goods from the factory.
Graham assumes no responsibility for deterioration of the equipment due to corrosion, erosion, or flow induced tube vibration, or for fouling, maintenance problems or any other causes not specifically covered under the foregoing warranty. The sole remedy of Buyer with respect to any part not conforming to any warranty of Graham shall be the repair or, at Graham’s option, replacement of any defective part at the point of manufacture, Buyer assuming all costs of removal, shipping, and reinstallation, provided that immediate written notice of the defect has been given to Graham, and Graham shall not be liable for any other expenses incurred because of failure of any part to meet Graham’s warranty, nor for any special, indirect or consequential damages. Material returned to Graham’s factory without its written consent will not be accepted.
No back charges will be honored without Graham’s advance approval of the work to be performed. Graham’s liability on any claim of any kind, including negligence, for any loss or damage arising out of, connected with, or resulting from this transaction, or the design, manufacture, sale, delivery, resale, installation, technical direction of installation, inspection, repair, operation, or use of any equipment covered by or furnished hereunder shall in no case exceed the price paid by Buyer for the equipment. Graham also disclaims all liability, whether in contract, tort, warranty, or otherwise, to any party other than the Buyer.
In the event the pumps are altered or repaired by any person or entity other than Graham, without written approval by Graham, all warranties are void. Bearings and shaft seals are warranted only to the extent of, and pursuant to, the original manufacturer's warranty
25
Graham Corporation
Appendix A
MATERIAL SAFETY DATA SHEET
26
Graham Corporation
27
Graham Corporation
28
Graham Corporation
Appendix B
For Return Material Authorization visit the Graham web site at www.graham-mfg.com.
SAMPLE FORM
RETURN MATERIAL AUTHORIZATION FORM
(This section completed by authorized Graham personnel only. Use Tab Key or Cursor to complete areas.)
TO: Date:
FROM:
(Customer’s Name & Company Name)
Fax No.:
RMA Number:
(Originator -- Auth. Graham Personnel)
(current date, auth. Graham personnel initials,01, 02, etc. as applies for that date)
E-Mail:
RMA Number Assigned by Authorized
Graham Batavia Personnel Only
Sections A, B, & C to be completed by the customer and RETURNED VIA FAX to the Graham Service
Department. For E-mailed form, use Tab Key or Cursor to complete areas. An additional copy must also be included with the returned equipment. No work will be started on the equipment being returned until the
Service Department has the completed form.
MSDS (Material Safety Data Sheet) must be included for all material(s) handled by the equipment. Work on the equipment will not begin until MSDS sheets are received. This is to ensure the safety of all Graham employees who may come in contact with this equipment.
The equipment must be cleaned, drained and DECONTAMINATED prior to shipping back to Graham.
Equipment returned in an unsatisfactory condition will be returned to the sender.
A. Customer Data
Customer:
Mailing Address:
Contact Person:
Phone Number:
Fax Number:
E-Mail:
B. Graham Equipment Information
Graham Serial No.:
ASME Unit?: NO
Type of Equipment / Model No:
Material Handled by Equipment:
Reason for Return:
C. Authorized Customer Signature
YES - Engineering Procedure EP-006 applies
Send equipment, RMA form and MSDS sheets to the address shown above, Attn: Service Dept.
Graham Corporation is not responsible for any freight charges.
(Units must be returned with freight prepaid or they will not be accepted.)
29
Graham Corporation
Appendix C
Pump Information
Frame
Size
D.E.
Bearing
N.D.E.
Bearing
Packing
(mm)
Side
Clearance
0.000"
/10 & /13
Side
Clearance
0.000" /20
Mechanical
Seal Size
DN (mm)
LXP30
LXP55
PV31060
PV31080
PV31110
PV32000
PV41000 6308-2Z
PV42000 6306-2Z
PV51160 6308-2Z
PV51200 6310-2Z
N/A
N/A
6-7
55
43
55
6-8 8-10 38
4-5 6-8 55
6-8 8-10 38
4-5 6-8 55
PV52000 6308-2Z
PV61000
PV62000
PV71000 NJ313 EC 6313
PV72000 21314-CC
8-10 10-12 43
PV81000 22320-C
PV82000 22320-C
PV91540
PV91305
NU222 (2) 13-15 *
PV91670
PV91335
NU226 (2) 13-15 *
PV10100 32230 (2) 18-20 *
PV11100 32234 (2) 20-24 *
PV12100 32238 (2) 24-28 *
PV13100 32244 (2) 26-30 *
* Consult Factory
Bolting Torque Values
N-M 10 25 50 85 205 ft-lb 7.4 18.5 37.0 63.0 151.9
Note: Values are subject to change without notice.
30
Graham Corporation
Appendix D
Two Stage Pumps
Frame Size
Avg Dry Weight
(kg)
32000 75
42000 120
52000 150
62000 300
72000 650
82000 1600
Single Stage Pumps
Frame Size
LXP
31000
41000
51000
61000
71000
91000
101000
111000
121000
131000
Avg Dry Weight
(kg)
20
75
120
150
250
600
1800
3500
5000
8000
12000
Avg Dry Weight
(lbs)
165
265
330
670
1440
3520
Avg Dry Weight
(lbs.)
45
165
270
340
550
1325
4000
7800
11000
17700
26500
31