Advertisement
Advertisement
USER'S MANUAL
RF VAC
High Frequency Massager(BOTEMCUBE)
(Rev. 0) 2018. 8. 20.
BOTEMCUBE Manual
ㆍ please be sure to read this manual and be aware of the device before using this product.
ㆍ Do not use this product for other than intended usage.
Table of Contents
Chapter 1. Information for Safe Operation
Chapter 2. Description of the device
Chapter 3. Description of the function
Chapter 4. Performance
Chapter 5. Operation of the device
Chapter 6. Storage and Maintenance after use
Chapter 7. Safety Warning
Chapter 8. When the device cannot be used
Chapter 9. Checklist before after-sales service request
Chapter 10. Labelling and Marking
Product Warranty
08
09
11
13
20
21
04
05
07
22
23
Information for Safe Operation
1. Intended use of the device
Device applying High-frequency energy to human body to massage, etc.
2. Outline of the device
Using physical energy such as pressure and stimulation and applying
High-frequency energy to human body.
3. Risk of Explosion and Fire
Do not operate the equipment in the presence of volatile substances such as an inflammable anesthetic mixture, alcohol, gasoline or solvent. Keep a fire extinguisher around.
4. The Use of Suitable Power Supply and Power Plug
Use power supply and power plug in compliance with the specification of the equipment. Use power plug in good condition.
Always disconnect a power cord by pulling a plug not a power cord.
5. Connection of Devices
This equipment is connected with a protective earth ground through the power cord. Proper and sufficient grounding is essential for safe operation of the equipment. Use only power strips with 3 prongs to maintain the best condition of earth grounding.
6. Replacement of Fuse
User can replace a fuse located in the compartment beside of the power cord socket. Only a qualified service personnel is allowed to access to the internal parts of the equipment. Correct type and rating of fuse should be used for a safety purpose.
7. Intended Operator
a) Education :
–. Junior college graduate or above b) Knowledge :
–. Understand High frequency treatment
–. Understand hygiene c) Language :
–. English (languages provided in user's manual), or literacy to properly understand
user's manual d) Experience :
–. No particular experience required e) Permissible impairments :
–. mild reading vision impairment or vision corrected to log MAR 0,2 (6/10 or 20/32)
–. 40% of disability causing 60% of normal hearing in the range of 500 Hz ~ 2 kHz
–. One hand to lead and hold the device
- 04 -
Description of the device
1. Main Body
●
Front Side
Cradle of handpiece cable
LED Display
Power and control button
Logo
●
Rear Side
Handpiece Cale
Handpiece
Cradle of handpiece cable
Cable socket
●
Accessory : Handpiece(Large, Medium, Small), Power Cable
- 05-
Vacuum pump filter
DC Adapter socket
Ventilation part of cooling fan
Description of the device
2. Handpiece
●
Handpiece L
●
Handpiece M
●
Handpiece S
- 06 -
Description of the function
①
②
③
④ ⑤ ⑦ ⑨
⑥ ⑧
⑩
⑪
⑫
⑬
LCD Screen
① High frequency(RF) level up button
② RF output display
③ RF level down button
④ RF output level display
⑤ Time display
⑥ Time control button
⑦ Vacuum suction mode display
⑧ Vacuum suction mode control button
⑨ Vacuum suction level display
⑩ Vacuum level up button
⑪ Vacuum output display
⑫ Vacuum level down button
⑬ Start/stop button
: Increase the RF level step by step.
: Informs start of high frequency operation.
: Decrease the RF level step by step.
: Displays 1 to 10 level of high frequency output.
: Displays time of use.(It goes down by a minute from initial 15 minutes)
: It can be controlled by 5 minutes from 5 to 60 minutes.
: Display vacuum suction mode in 3 types.
: Fast, slow, continous modes.
: Displays 1 to 4 level of vacuum suction.
: Increas the Vacuum level step by step.
: Informs start of Vacuum suction operation.
:Decrease the Vacuum level step by step.
: Button to start/stop operation of device.
- White LED : ON
- Blue LED
- Red LED
: OFF
: Error (disconnected handpiece cables)
- 07 -
Performance
1. Performance
① Rated Voltage & Rated Frequency : AC 220V , 50/60Hz
② Time display of operation : Time down counter by minute
③ Power consumption : 70VA
④ Protection type and level regarding electric shock : Ist Grade, BF type Equipment
⑤ Frequency : 500KHz ± 10%
⑥ Pulse Duration : 1.0㎲ ± 10%
⑦ Output voltage : Max. 45rms-V ± 10%
⑧ Output current : Max. 90mA ± 10%
⑨ Vacuum pressure : Max. 550mmHg ± 10%
⑩ Timer : 5 min.~60 min.
2. Product Specification
Model
Size(mm)
Weight
Rated Voltage &
Rated Frequency
Frequency
Output current
Output current
BOTEM CUBE / ABC-01P
240(Length) X 250(Width) X 170(Depth)
5kg/set
220V/50-60Hz
0.5MHz
Max. 90mA
Max. 550mmHg
3. Environment Condition
① Temperature : 0~40 ℃
② Humidity : 20~80 %
③ Air pressure : 500~1060 hPa
- 08 -
Operation of the device
1. Connection of handpiece cable
① Connect one plug of handpiece cable to the connector socket of the main body.
② Connect the plug and socket at the right position of connection and complete the connection by turning the connector cap to the screw locking direction.
2. Connection of handpiece
① Connect the handpieces to the cable and screw locking direction.
② Check and complete the connection as the same as #1.
3. Connection of power switch
①
②
③
Connect the DC adapter into the power socket at the back of main body.
Connect both sides.
Connect the power socket and power cord at the back of main body to AC 220V/100V outlet.
④ Display the blue LED light when the connection is correctly.
⑤ hen the connection is normal, the logo sign is flickering.
③
① ②
④
(파란색 램프)
⑤
(하얀색 램프)
4. Power switch conditions
① When turn on upon pressing power button, white LED light is shown.
☞ Power LED light colors
White : ON
Blue : OFF
Red : Error (disconnected the handpiece cables)
- 09 -
(하얀색 램프)
Operation of the device
5. Control of time settings
① Setting the time by the time control buttons when the power is on.
② Increase 5 times each pressing the time button up to 60 minutes.
(5,10,15,20 ~ 55,60)
6. Control of High frequency output
① When press the level up button(▲), the RF output levels up step by step.
(The handpiece LED is on and the time decreased per a minute)
② The RF level is from 1 to 10 controlled by (▲), (▼) buttons.
7. Control of vacuum suction pressure
① When press the level up button(▲), the Vacuum suction levels up step by step.
(In the condition of Vacuum suction only, the LED is off and the time decreased er a minute)
② The Vacuum suction level is from 1 to 4 controlled by (▲), (▼) buttons.
③ 3 modes for Vacuum suction pressure (fact, slow, continues) by controlling the mode control button.
8. Power off
① The device goes back to initial mode (the mode when it is powered)
(The the power off = the blue LED light)
② Setting values are maintained and operation stops upon pressing
Start/Stop button during treatment and operation restarts upon pressing
Start/Stop button again .
- 10 -
Storage and Maintenance after use
1. Maintenance after treatment
① Disconnect the DC adapter from the power socket and the power cord.
② Disconnect handpiece from the cable and clean it with alcohol, cotton swab and soft cloth for maintenance.
③ Vacuum pump filter at the back of main body should be regularly checked and cleaned to remove foreign substances.
2. Clean of the power socket and the adapter socket
① Check if there is dust or foreign substance when connecting power cable into power socket and the adapter socket.
② If any, remove dust and foreign substance with soft brush.
3. Clean of the main body
① Clean the main body with soft cloth.
② Do not clean it with water or organic solvent (thinner, benzene, etc).
4. Clean of the handpieces
① Clean the head of handpiece thoroughly with alcohol.
② Clean the edge of handpiece and passage to vacuum suction with cotton swab.
③ Prevent skin infection through cleaning the device after every use.
- 11 -
Storage and Maintenance after use
5. Clean of the vacuum pump filter
① Frequently check if filter is full of foreign substance at the back of main body.
② If the filter is full enough, turn the filter to the right.
③ Clean the filter thoroughly.
④ Reassemble the filter clearly.
6. Storage method
① Avoid direct sunlight.
② Avoid where heat is generated with inflammable materials.
③ Separate from chemicals.
④ Unplug the device when it is not used.
⑤ Avoid dust and foreign substance.
⑥ Avoid humidity and keep in a place where it is not exposed to water.
- 12 -
Safety Warning
- Make sure to understand and observe 'Safety Warning' since it is to prevent any accident or risk in advance
through right and safe use of the device.
- 'Safety Warning' includes all cautions both before and during use.
- 'Safety Warning' is divided into 'Warning' and 'Caution,' which means as follows.
Warning :
Matters that can incur serious danger such as death or serious injury
Caution :
Matters that can incur slight injury or potential danger
Warning
Use the device only with the supplied DC adapter and power cord and do not simultaneously use different plugs in one outlet.
* Wrong voltage and current rating can cause electric shock or fire.
* Using a transformer can cause electric shock or fire.
Stop using the device when power cord or power plug is
damaged or shaken.
* It can cause electric shock or fire.
* Replace the power cord and power plug immediately.
Hold the power plug when unplugging it.
* Pulling the plug out by force can cause electric shock or fire due to abnormality of power cord.
- 13 -
Safety Warning
Warning
Clean the power cord and power plug with dry cloth when it is contaminated.
* Dust or pollutant can cause electric shock or fire.
Do not bend, tie or pull the power cord by force.
* It can cause electric shock or fire due to short circuit.
Dry your hand when plugging in and eliminating the power cord.
* Holding the power plug with wet hand can cause electric shock or fire.
Do not disassemble or arbitrarily alter the device.
* The device should not be disassembled or arbitrarily altered by
anyone other than service engineer.
* It can cause abnormality or breakdown of the device.
* Do not disassemble the adapter, and it can cause electric shock,
fire or explosion.
Do not install or use the device in a place with inflammable materials or danger of explosion.
* It can cause electric shock, fire or explosion.
- 14 -
Safety Warning
Warning
Do not use the device in a bathroom or a place with high humidity.
* It can cause electric shock or fire due to short circuit.
Only use the RF cream for the skin care or massage the body.
* It can cause injury.
Do not use high frequency or vacuum suction on wound, lips, eye or ear.
* It can cause injury.
Start treatment with high frequency and vacuum suction from low level.
* It can cause injury.
Do not apply high frequency or vacuum suction at a single spot.
* It can cause burn or injury.
* Do not exceed a second as to treatment at a single spot.
- 15 -
Safety Warning
Warning
Do not bend or pull the handpiece cable by force.
* It can cause injury or breakdown of the device.
Do not use with other inductive electric appliances.
* It can cause breakdown of the device.
Stop using the device and immediately contact to the service center when it makes strange sound, smell or smoke.
* It can cause electric shock or fire.
Do not apply to children and keep and use it out of the reach of children.
* It can cause injury, electric shock or fire.
Disconnect the power plug unless the device is being used.
* It can cause electric shock, short circuit or fire.
- 16 -
Safety Warning
Caution
Do not apply excessive force on the device when installing it.
* It can cause breakdown of the device.
Install the device on flat and hard floor.
* It can cause vibration or noise.
* It can cause breakdown of the device.
Install the device for the back side of main body not to lean against the wall.
* It can cause breakdown of the device.
* Install the device at least 20cm off from the wall.
Apply the handpiece head into skin as close as possible.
* It can cause injury.
Do not disconnect the power plug and DC adapter or move the device during operation.
* It can cause injury or breakdown of the device.
- 17 -
•
Safety Warning
Caution
Check for abnormal operation or damage of handpiece before contact with skin.
* It can cause burn or injury.
Lower the high frequency and vacuum suction level when a patient complains of pain during use.
* It can cause burn or breakdown of the device.
Stop using the device immediately when any abnormality on skin is detected.
* It can cause burn or breakdown of the device.
Clean the handpiece head and hole with cotton swab and soft cloth and sterilize them with alcohol after use.
* It can cause infection or side effects.
* It can cause breakdown of the device.
Check the filter at the back side and if any foreign substance is detected, clean the device after use.
* It can cause breakdown of the device.
* It is recommended to regularly clean the filter.
- 18 -
Safety Warning
Caution
Keep the handpiece, handpiece cable, main body and power cord separately after cleaning the device.
* It can cause breakdown of the device.
When the device is of abnormality or does not work, read through 'Checklist before after-sales service request' and contact to the service center if the problem you have is not subject to any item.
Use the handpiece after checking the label. As to handpiece, what is provided by the company should only be used.
Do not use the device in the same place where there is equipment generating strong electromagnetic wave (e.g. X-ray, MRI, etc).
☞ Contact : Asnac Corp., Service Center : 051-634-2929
- 19 -
When the device cannot be used
Do not use the device under conditions below.
- Children
- Pregnant woman
- Disease (Heart disease, Skin disease, Liver disease, Kidney disease, Malignant tumor , Cancer, Diabetes)
- Abnormal blood pressure
- Perceptual disorder
- Patient with infectious disease
- hose who are taking medicine for infection
- Sensitive Skin
- Hypertrophic scar
- Those who are with implantable medical devices
(people with implantable medical device which affects to electromagnetic waves such as implantable cardiac pacemaker, implantable defibrillator, implantable electronic stimulator for medical use, implantable electronic urination suppressor, etc.)
- 20 -
Checklist before after-sales service request
If the device does not work even after checking and making corrective actions, contact to the service center.
C h e c k a n d C o r r e c t i v e A c t i o n s Problem
The Red LED light is displayed on
LCD screen.
① Check the handpiece cable connection.
Handpiece and handpiece cable is not connected.
Main body and handpiece cable is not connected.
Handpiece cable is not pulled out from handpiece and main body.
Hot air blows from the
back side of the device.
Button does not work.
Power is not turned on.
① Check if connection display matches and connection is in contact.
② Check if there is any damage or short circuit on handpiece cable joint.
① Check if connection display matches and connection is in contact.
② Check if there is any damage or short circuit on handpiece cable joint.
① Check if the screw cap of the connector is loose.
② Pull out by applying parallel force in the opposite direction of connection.
① It is normal since the device is subject to operation of cooling fan.
② Check if the device is installed at least 20cm off from the wall.
① Turn off and then turn on the power switch to check the operation.
② urn on the power switch at least 5 minutes after turning it off since error may be incurred for use with a wet hand or c loth.
③ Check the handpiece cable connection.
① Check if the DC adapter is properly connected to the power socket.
② Check if the power cord is properly connected to the power socket.
No heat is generated on the handpiece.
① Check the display on RF level.
② Check the heat generated while gradually raising the RF level.
Vacuum suction pressure is too low.
① Check whether the filter is full of foreign substance.
② If so, clean or replace the filter.
Noise is too loud.
① Check the level of noise since vacuum suction pump generates noise.
② Check if the device is installed on flat and hard floor.
③ Check if the device is installed at least 20cm off from the wall.
④ When noise is generated irregularly or it is too loud, contact to the service center.
- 21 -
Labelling and Marking
1. Label
1) Description of the label
Symbol Description
Manufacturer
Serial Number
Model name
Type BF Device
Pushing prohibited
WEEE Symbol
Symbol
2) Product Label
Product Name High Frequency Stimulator
BOTEM
ASNAC Corp.
3F, 31 Sasang-ro 35 Beon-gil, Sasang-gu, Busan, Korea
Tel: 82-51-634-2929 Fax: 82-51-955-2929
Homepage : http://www.asnac.co.kr
Description
Authorized Representative in the
European Community
Date of Manufacture
Caution
Follow operating instructions
General warning sign
Weight 5kg Quantity
Read User's Manual Before Operating
Input Voltage 100-240V~ Consumption Electricity
1 SET
3 KVA
- 22 -
Product Name
Serial Number
Customer Name
Address
Agency
Address
Note
Product Warranty
Model Name
Sales Date
Tel.
Tel.
ASNAC
3F,31,Sasang-ro 35beon-gil, Sasang-gu Busan, South Korea
☞ When asking for repair, you need to present this product warranty on which date of purchase is
written for proper service so keep this document carefully.
① Warranty of this product is provided as written in the product warranty.
② One-year free warranty period is calculated from the date of purchase so have the date written on the warranty.
③ This product warranty is not to be reissued.
Warranty
1 year
Compensation for Consumers' Damages
Consumers' Damages
Compensation
Within warranty period After warranty period
When significant repair is required within 10 days of purchase
Product exchange or refund
For product's spontaneous breakdown on performance and function during normal use
(within warranty period)
When significant repair is required on major component within 1 month of purchase
When an exchanged product requires significant repair within 1 month
For occurrence of defect
When the same breakdown recurs (4th time) in spite of repair
When the same breakdown recurs (5th time) on different parts in spite of 4 times of repair
When the product is irrepairable
When the product is irrepairable in the absence of necessary component
Product exchange
Free repair
Product exchange or refund
Refund by adding 10% to depreciation of list price
When the company loses the product on which a consumer asks for repair
For damages incurred during shipping and installation upon purchase
When the product is repairable
Warranty of the product caused by misuse or fault of the user shall be void
When the product is irrepairable in the absence of necessary component
Product exchange
Repair at a cost
Product exchange after charging sum of cost for repair and depreciation of list price
Repair at a cost
• When breakdown is incurred for natural disasters (fire, earthquake, storm, flood, etc.)
• When consumable components are replaced which are subject to natural abrasion
• When breakdown is incurred for abnormal use of power supply and defects in connecting parts
• When defects on product are not internally but externally caused
• When breakdown is incurred for repair or alteration made by someone other than service engineer from selling agency or service center
Repair at a cost Repair at a cost
* Life of the product is 5 years in accordance with the company's rules. (Appropriation of 20% annual depreciation)
• As to matters not described above, compensation for damages is to be offered in accordance with standard of consumer
dispute settlement in Framework Act on Consumers.
☞ Before requesting the service, look through the checklist of user's manual.
☞ Contact : Asnac Corp., Service Center : 051-634-2929
- 23 -
3F, 31, Sasang-ro 35beon-gil, Sasang-gu Busan, South Korea
Tel. 051-634-2929 Fax. 051-955-2929

Public link updated
The public link to your chat has been updated.
Advertisement