Modena MARVEL AIR PURIFIER AP 2531 MAVA User manual
Advertisement
Advertisement
User Manual Book
Air Purifier
Purificato Series
AP 2531
TABLE OF CONTENT
Part 1: Important Safety Information
General Cautions
Prohibitions
Warnings
Notices
Part 2: Product Introduction
Product Components
Control Panel and Display
Part 3: How to Use
Panel and Display Instruction
Air Quality Indicator
Part 4: Maintenance
Part 5: Troubleshooting
Part 6: Specification
Appendix: Wiring Diagram
This manual book explains everything you need to know about your new product. Please contact our Customer Care should you need further assistance through www.modena.com.
6
6
7
8
9
10
4
4
5
5
5
6
3
3
3
English 2
PART 1: IMPORTANT SAFETY INFORMATION
General Cautions
1.
Please check whether the device is fine and the components are complete after unboxing the package.
2.
Please be sure to remove the plastic package of the filter before first time using the device.
3.
Children and incapacitated person should use the device accompanied by their superintendent.
4.
Please unplug the device immediately if accident occurs, and do not use the machine under defect condition.
5.
In order to avoid danger, if the supply cord is damaged, it can only be change by manufacturer or the qualified maintenance person.
6.
Please do not use other components that are not permitted by manufacturer, otherwise warranty will be terminated if the device is breakdown in that case.
Prohibitions
1.
Do not put your hand and foreign matter into the air inlet and air outlet.
2.
Do not unplug the power with wet hands.
3.
Do not use the device at the place where full of hydogen, natural gas, dimethylmethane, and other flammable gas.
4.
Do not use the device if power cord or plug is damaged, or power socket slacked off.
5.
Do not jam the air inlet and air outlet
6.
Do not use the device when using the aerosol bomb or there are oil residue, incense smoke, alight flame, and chemical odor in the room.
And also do not use the device in deep wet place such as shower room.
7.
Do not operate the device without filter inside.
8.
Do not wash or re-use the composite filter.
English 3
Warnings
1.
Only 220V voltage socket can be used.
2.
Hold still the plug when unplug it, and do not pull the power cord, otherwise it will cause electric shock or sparks.
3.
Unplug the device when not in use or need cleaning.
4.
Clean the dust on the plug regularly.
5.
Do not use strong causticity detergent when cleaning the device because it can damage its surface.
6.
Use only soft cloth to clean the surface of the device, oherwise it will be damaged, scratched, or even fractured.
7.
Do not put the device close to the heat source or even put onto it.
8.
Ethyl alcohol or organic solvent are forbidden to be used to wipe the device, otherwise it will damage the device or cause electric shock and fire sparks.
Notices
1.
User can directly push the device or hands hold on both sides of the buckle to move it. If user hold the air outlet, it is possible to make the air outlet or the host device fall off, which can cause injury.
2.
This device is not intended to be used by persons with special needs for their physical, sensory or mental capabilities, or lack of experience and knowledge (including children), unless they have been given the supervision or instructions concerning the use of the appliance by a person who responsible for their safety. Children should be supervised to ensure that they are not playing with this water heater.
3.
If the device causing signal interference on the radio or television, please follow one or more below instructions:
• Re-adjust or rotate the receiving antenna.
• Take the device far away from radio or television receiving antenna.
• Connect the air purifier power and signal power on different socket.
• Please contact MODENA Service Center or qualified technician if assistance is needed.
English 4
PART 2: PRODUCT INTRODUCTION
Product Components
Air Outlet
Control
Panel
Rear Cover
Sensor
Fuselage
Air Inlet
Power
Plug
Base
Control Panel and Display
Power Button
Ion Function
Filter Indicator / Reset
Fan Speed Adjustment
Auto Function
Timer and Child Lock
English 5
Button Instructions
PART 3: HOW TO USE
Turn the device on or off. When the device is turning on, it will triggers the air quality detection system to open and the digital display will flash for about 30 seconds. Once the air quality detection test is completed, the air quality condition is informed by the digital display as well as the air quality indicator lamp.
Select the speed of the wind. 1 for low, 2 for medium, 3 for high speed, and 4 for sleep mode.
Activate the intelligent mode. If this fuction is activated, the device will automatically adjust the wind speed based on the air quality detected by the sensor.
These button has two functions. Quick tap this button to set the timer. 1 tap for 1 hour, 2 taps for 2 hours, and so on. Time can be set until 8 hours. To activate the child lock function, long press on the button for about 3 seconds. This button indicator will turn on, and other buttons are not functional. Long press the this button again for 3 seconds to unlock it, indicator light will be off and all the buttons is back to functional again.
Activate the anion function. Tap the button once to activate and tap once again to deactivate it. Anions electrically neutralize and remove bacteria, dust, pollen, mold, and contaminated particulates which are freely float and make foul air.
If the filter button flashing in red, it means that the filter can be used only for next 48 hours and user need to change the filter.
To reset the filter, long press the filter button until the red light stop flashing.
Air Quality Indicator
Excellent
Green
Good
Blue
Poor
Red
Air Quality Status
Indicator Light Color
Air Quality Value
Wind Speed
1 – 75 μg/m3 75 – 150 μg/m3 > 150 μg/m3
Gear 1 / low Gear 2 / med Gear 3 / high
English 6
PART 4: MAINTENANCE
Warning: The device must be unplugged before maintenance and cleaning
Device Cleaning
1.
Wipe stains with soft cloth.
2.
For stubborn stains, dip some neutral liquid into the soft cloth then clean.
Note: No hard object to scratch the device surface during maintenance and cleaning. When tear down the device, please refer to the instruction manual and do as the requirement to avoid damaging the components.
Filter Cleaning and Replacement
1.
Built-in program will remind to replace the filter. Due to different air quality around, filter lifetime will also be different. Filter replacement also can be judged from the device noise and smell.
2.
If there is dust cover on the composite filter, a vacuum cleaner can be used to clean the dust on its surface to extend filter lifetime.
Notes:
• Filter lifetime can shorten if being used for certain condition, such as in a room where many people smoke. Please replace the filter when purify effect is not good anymore.
• Please dispose the used filter as non-combustible garbage.
Filter Replacement Method
1.
Power off the device and unplug the power plug. (Pic. 1)
2.
Open the rear cover from the buckle. (Pic 2).
3.
Take out the old filter. (Pic 3)
4.
Remove the plastic packaging from the new filter. (Pic 4).
5.
Insert the new filter into the device. (Pic 5).
6.
Put the rear cover back to its original position. (Pic 6).
English 7
Dust removal effect is not obvious and air quality does not get better
1.
No filter in the device.
2.
Door or window of the room open frequently.
3.
The device is put in narrow place or close to barrier around.
4.
The filter is dirty.
PART 5: TROUBLESHOOTING
Problem
The device cannot be turned on
The air flow is weak
Possible Cause
The device does not plug well.
1.
Filter package has not been removed.
2.
Foreign materials jam the air inlet or outlet.
3.
The filter is dirty.
Recommended Actions
Check the power plug and re-plug it properly
1.
Remove the plastic package of the filter.
2.
Clean foreign material at the air inlet or outlet.
3.
Clean or replace the filter.
1.
Install filter into the device.
2.
Reduce the door or window opening frequency.
3.
Move device to wider place without any barrier.
4.
Clean or replace the filter.
Odor comes from the air outlet
1.
Many people smoke or do something causing odor in the room.
2.
The filter is dirty.
1.
Change the indoor air.
2.
Clean or replace the filter.
English 8
PART 6: SPECIFICATIONS
Model
Product Type
Color
Control Panel
Filter Composition
AP 2531
Room Air Purifier
White
Touch Control
Pre-Filter, Activated Carbon, Anti-Bacteria Cloth,
HEPA13
No WIFI Function
Negative Anion Function
Fan Speed
Display
Timer Setting
Air Quality Indicator
Sleep Mode
Auto Mode
Light Sensor
Yes
Low / Mid / High
Yes
Yes, 1-8 hours
Yes, Green-Blue-Red
Yes
Yes
No
Filter Replacement Indicator Yes
Child Lock Yes
Rated Voltage
Power
Clean Air Delivery Rate
220 V/ 60 Hz
50 W
260 m3/h
Coverage Area 25 m2
Dimension 294.5 x 294.5 x 606 mm
Specifications of this appliance may change without notice to improve the quality of the product. Pictures in this manual are schematic and may not match your product exactly.
Values stated on the machine labels or in the documentation accompanying it are obtained in laboratory in accordance with the relevant standards. Depending on operational and environmental conditions of the appliance, values may vary.
English 9
APPENDIX: WIRING DIAGRAM
Capacitor
White
Yellow
Anion Generator
Power Supply
Board
Power
Supply
PM 2.5 Sensor
Control
Panel
English 10
NOTE :