Buchi F-100 Installation Manual
Advertisement
Advertisement
Recirculating Chiller
F-100 / F-105
Pre-installation checklist
The following checklist will assist you in site preparation for your BUCHI instrument. Careful attention to the requirements presented in this document will help simplify instrument installation and ensure that the instrument operates as it was designed.
Recirculating Chiller F-100 / F-105
Pre-installation checklist
All appropriate items in this checklist must be completed, signed and returned to BUCHI. Re-turn your checklist as soon as your laboratory is ready and functional for prompt installation of your
KjelMaster. If you are performing self-installation, please check the box f or self-installation below and return the form to BUCHI.
Environmental requirements
Ambient Temperature 5 to 35°C
Humidity Maximum relative humidity 80 % for temperatures up to 31 °C decreasing linearly to 50 % relative humidity at 40 °C
Altitude max. 2000m above sea level .
Space requirements
Enough space as defined below: (Width x Depth x Height) min. 280 x 500 x 420 mm
The instrument must have a clearance of 40 cm between itself and the wall, both in front and behind (sufficient cooling).
To ensure that the power can be cut by unplugging in case of an emergency, the mains plug must not be blocked by the instruments or any other items!
1
Location of the unit
The recirculating Chiller F-100 and F105 must be installed on a clean, level, vibration free surface.
Power requirements
The F-100 / F-105 requires its own standard mains outlet socket. A standard mains cable is supplied.
2
Recirculating Chiller F-100 / F-105
Pre-installation checklist
Other Requirements
Detailed T echnical requir e ments
I have reviewed the detailed Technical Data on www.buchi.com/media-center.
My facility fullfills the required specifications.
Facility sign-off
Return your checklist as soon as your facility is ready and functional for prompt installation of your
KjelMster.
Environmental Requirements as specified for your facility
Space Requirements
Other Requirements
Power Requirements
Self-Installation
3
Recirculating Chiller F-100 / F-105
Pre-installation checklist
Please enter the following information and sign below:
Company name
Customer name
Contact number
Purchase order no.
I certify that the preparations required for the installation of the KjelMaster have been completed and functional as described in this document.
I further acknowledge that if any of these requirements are not ready by the agreed upon installation date and I have not rescheduled the installation, then I will be responsible for any additional costs relating to the installation of the system.
Customer signature Date
Please sign and return by fax or email to BUCHI as soon as your laboratory is ready for installation:
Attention:
Find your BUCHI Affiliate or partner on: https://www.buchi.com/en/worldwide
If you have any questions or queries, then please do not hesitate to contact us.
Recirculating Chiller F-100 / F-105
Pre-installation checklist
Quality in your hands
Find your BUCHI Contacts:
BÜCHI Labortechnik AG
CH – 9230 Flawil 1
T +41 71 394 63 63
F +41 71 394 65 65 [email protected]
www.buchi.com
BUCHI Italia s.r.l.
IT – 20090 Assago (MI)
T +39 02 824 50 11
F +39 02 57 51 28 55 [email protected]
www.buchi.it
BUCHI Hong Kong Ltd.
HK – Central
T +852 2389 2772
F +852 2389 2774 [email protected]
www.buchi.com.cn
BÜCHI Labortechnik GmbH
DE – 45127 Essen
Freecall 0800 414 0 414
T +49 201 747 490
F +49 201 237 082 [email protected]
www.buechigmbh.de
BÜCHI Labortechnik GmbH
Branch Office Benelux
NL – 3340 AC
Hendrik-Ido-Ambacht
T +31 78 684 94 29
F +31 78 684 94 30 [email protected]
www.buchi.nl
BUCHI Shanghai
CN – 200052 Shanghai
T +86 21 6280 3366
F +86 21 5230 8821 [email protected]
www.buchi.com.cn
BUCHI Sarl
FR – 94656 Rungis Cedex
T +33 1 56 70 62 50
F +33 1 46 86 00 31 [email protected]
www.buchi.fr
BUCHI UK Ltd.
GB – Oldham OL9 9QL
T +44 161 633 1000
F +44 161 633 1007 [email protected]
www.buchi.co.uk
BUCHI (Thailand) Ltd.
TH – Bangkok 10600
T +66 2 862 08 51
F +66 2 862 08 54 [email protected]
www.buchi.co.th
Nihon BUCHI K.K.
JP – Tokyo 110-0008
T +81 3 3821 4777
F +81 3 3821 4555 [email protected]
www.nihon-buchi.jp
BUCHI India Private Ltd.
IN – Mumbai 400 055
T + 91 22 667 75400
F +91 22 667 18986 [email protected] www.buchi.in
PT. BUCHI Indonesia
ID – Tangerang 15321
T +62 21 537 62 16
F +62 21 537 62 17 [email protected]
www.buchi.co.id
BUCHI Korea Inc
KR – Seoul 153-782
T +82 2 6718 7500
F +82 2 6718 7599 [email protected]
www.buchi.kr
BUCHI Corporation
US – New Castle,
Delaware 19720
Toll Free: +1 877 692 8244
T +1 302 652 3000
F +1 302 652 8777 [email protected]
www.mybuchi.com
BUCHI Russia/CIS
United Machinery AG
RU – 127787 Moscow
T +7 495 981 05 22
F +7 495 981 05 20 [email protected]
www.buchi.ru
We are represented by more than 100 distribution partners worldwide.
Find your local representative at: www.buchi.com
BUK-KjelMaster_0418A/ Technical data are subject to change without notice/ Quality Systems ISO 9001.
The English version is the original language version and serves as basis for all translations into other languages.

Download
Advertisement