CONTENT

I. Safety Precautions And Procedures ............................................... 1

1.

Preliminary Instructions ............................................................... 2

2. During Use ................................................................................... 2

3. After Use ...................................................................................... 3

II. Introduction ........................................................................................ 3

III. Model ................................................................................................. 4

IV. Electrical Symbols ........................................................................... 4

V. Technical Specification ..................................................................... 4

VI. Instrument Structure ........................................................................ 6

VII. LCD Display .................................................................................... 7

VIII. Method of Operation ..................................................................... 7

1.

Switch On/Off .......................................................................... 7

2. Data Hold/Storage ..................................................................... 7

3. Data Access/ Exit ...................................................................... 8

4. Data Upload .............................................................................. 8

5. Delete Data ................................................................................ 8

6. General Measurement ............................................................... 8

7. PEAK Measurement ............................................................... 10

IX. Battery Replacement .................................................................... 10

XI. Accessories .....................................................................................11

I. Safety Precautions And Procedures

This instrument was designed in compliance with IEC1010-1& IEC1010-2-032 safety guideline relative to electronic equipment.

For your own safety and to avoid damaging the instrument you are recommended to follow the procedures described in this manual and read carefully all instructions preceded by this symbol

Before and during measurements keep to the following instructions:

● Do not take current measurements in wet places

● Do not take the measurements in the presence of explosive gas and combustibles or in dusty places

● Avoid any contact with the circuit under test even though you are not taking any measurement

● Avoid any contact with exposed metal parts, unused measuring terminals, circuits etc. Do not take any measurement whenever anomalous conditions occur such as deformations, breaks, leakages, blind display etc

The herewith symbols are used in this manual and on the meter

CAUTION: refer to the instruction manual. An improper use may damage the instrument or its components as well as endanger the user.

High voltage danger: risk of electric shock

-1-

1. Preliminary Instructions

● This instrument has been designer for use in environments with pollution degree 2

● It can be used for voltage and current measurements on electrical installations with overvoltage CAT III 600V

● You are recommended to respect the usual safety regulations aimed at protecting you against dangerous current and protecting the instrument against improper use

● Only the original accessories supplied along with the instrument guarantee compliance with the safety standards in force. They must be in a good conditions and, if necessary, replaced with identical ones

● Do not test nor connect to any circuit exceeding the specified overload protection

● Do not take measurements under environmental conditions exceeding the limits indicated in this manual

● Make sure that batteries are correctly installed

2. During Use

You are recommended to read carefully the following instructions:

CAUTION

Failure to comply with warnings and instructions may damage the instrument and/or its components as well as injure the operator

● Do not measure in the presence of external voltages. Although the instrument is protected, an excessive voltage may cause malfunction

● Avoid submitting the instrument to voltage while measuring (i.e. a test lead slipping off the measuring point accidentally touching an energized point)

-2-

CAUTION

If the

“low battery” symbol

is displayed during use interrupt testing, switch off the instrument and replace batteries.

 (Take note of the polarity when replace the battery.)

3. After Use

● Turn off the instrument pressing ON/OFF key after using it

● If you expect not to use the instrument for a long time remove batteries

II. Introduction

ETCR7100 series of Super-large Caliber Leakage Clamp Meter is well designed and manufactured for measuring AC leakage current, current, voltage, adopt the latest CT technology and digital integrated technology. Its large caliber 108mm×148mm can clamp electric cable of 108mm diameter, or

160mm×4mm flat cable and steel earth wires. It has the biggest caliber and widest current range all over the world, particularly suitable for leakage current measurement of cable and transformer earth steel. Full automatically and

LCD display, all the data are displayed in the screen, which is very clear and convenient. The meter is widely used in electric power, communication, meteorology, railway, oil field, architecture, measuring, teaching research unit, industrial mining enterprises, etc.

ETCR7100 series of Super-large Caliber Leakage Clamp Meter

’s clamp core is made of special alloy, adopt the latest magnetic shielding techniques, to ensure the high precision, high stability and high reliability of perennial uninterrupted measurement. The meter can store 99 sets of data, with RS232 interface, upload stored data to the computer through the system

-3-

software, implementing online real-time monitoring, historical inquires, dynamic display. With the function of historical data read, preserve, print, and backlight, data hold, etc. It is a necessary tool for electrical safety testing.

III. Model

Model Range (AC) Resolution

ETCR 7100

0.0mA- 3200A

ETCR 7100A

0.0A- 4000A

0.1mA

0.1A

Note

Measure leakage current

Measure big current

IV. Electrical Symbols

Extremely dangerous! The operator must strictly abide by the safety rules; otherwise there is risk of electric shock, resulting in bodily injury or fatalities.

Dangerous! The operator must strictly abide by safety rules; otherwise there is risk of electric shock, resulting in bodily injury or fatalities.

Warning! Safety rules must be strictly abided by, otherwise personal injury or equipment damage may be caused.

Alternate Current

(AC)

Direct Current

(DC)

Double Insulation

V. Technical Specification

Function

Power

Measure AC leakage current, big current (particularly suitable for leakage current measurement of cable and transformer earth steel)

6V DC(LR6×4 alkaline dry batteries, continuously working for 12 hours)

Test Mode

Clamp CT, integral mode

108mm×148mm (can clamp electric cable of 108mm

Clamp Size

diameter, or 160mm×4mm flat cable and steel earth wires)

Measurement

ETCR7100: 0.0mA~3200A

-4-

Range(AC)

Resolution(AC)

ETCR7100A: 0.A~4000A

ETCR7100: 0.1mA

ETCR7100A: 0.1A

Measurement

Accuracy(AC)

(23°C±3°C, below 70%RH, measured wire at the center of the clamp)

0.0mA~499A ±2%±5dgt

500A~999A ±3%±5dgt

1000A~2999A ±4%±5dgt

3000A~4000A ±5%±5dgt

Measured Wire

Measured wire at approximately the geometric center

Position

of the clamp

Data Storage

99 sets,

FULL” symbol indicate the memory is full

With RS232 interface, download data to computer for

RS232 Interface

analysis and management

Communication

Wire

RS232 communication wire, 1.8m

Frequency

50Hz ,60Hz automatic identification

Gear Shift

Automatic shift

Sample Rate

About 2 times/second

Line Voltage

Below AC 600V line measurement

Display Mode

4 digital LCD display, length 47mm×width 28.5mm

Meter Size

Length 350mm × Width 180mm × Height 55mm

Backlight

Data Hold

Overflow

Automatic

Shutdown

Voltage

Detection

Suitable for dim places

HOLD” symbol appears

OL” symbol appears

Automatically shutdown about 5 minutes after power on to reduce battery consumption

Low battery symbol “ " appears to remind the replacement of battery when the battery voltage drops below 5.2V.

Weight of Meter

1.5kg (with batteries)

Weight of

Package

Working

Temperature and Humidity

Storage

Temperature

3kg (with accessories)

-10°C ~ 40°C; 80%rh

-10°C ~ 60°C; below 70%rh

-5-

and Humidity

Insulation strength

Safety

Specifications

AC 2kV/rms(between core and shell)

IEC1010-1, IEC1010-2-032, 2 class of pollution, CAT

III 600V

VI. Instrument Structure

1. Clamp (108mm×148mm)

2. Lock switch (after lock, the clamp can

’t be open)

3. HOLD key 4. PEAK key

5. LCD display 6. RS232 interface

7. Opening lever 8. POWER key

9. Battery cover 10. Battery cover screw (1 piece)

11. Up and down cover connecting screws (6 pieces)

-6-

VII. LCD Display

⑴. PEAK measurement mode symbol

⑵. Symbol of low battery & voltage (display when below 4.8V)

⑶. Symbol of data storage

⑷. Symbol of data access

⑸. 2-digital No. of data storage unit

⑹. Current unit (mA or A)

⑺. Data lock symbol

⑻. Metrication decimal point

⑼. 4-digital LCD figures display

⑽. Symbol of AC

VIII. Method of Operation

1. Switch On/Off

Press POWER key to switch on, LCD display, in test mode, press

POWER key to switch off. The meter will automatically power off after booting 5 minutes later. If LCD display is darker, maybe the battery voltage is too low, please replace batteries.

In data hold mode, firstly press HOLD key to cancel the lock, then press POWER key to switch off.

2. Data Hold/Storage

In test mode, press HOLD key to lock currently displayed value and display

HOLD “symbol. At the same time, this locked value as a set of data followed by auto-ID and store, and

MEM” symbol flash one time. The meter can store 99 sets of data. If the memory is full, display

FULL” symbol.

-7-

3. Data Access/ Exit

In test mode, press PEAK and POWER key to access data inquiry form group

R01”, and display “MR” symbol. Press PEAK or POWER key to increase or decrease the page number, it will automatically return back to group 01 when access the last group.

Press HOLD key to exit date inquiry, back to test mode.

4. Data Upload

Connecting the meter and computer with USB-RS232 communication line attached in package. Start up the meter, run software, choose history access, then read, save, report, print history data, etc. The more data storage, take the longer time to read it. Historical data can be saved in Txt text or Excel format.

5. Delete Data

In the date inquiry mode, press PEAK and POWER key to delete all the stored data, and return back to test mode. At the same time,

dEL” symbol display.

6. General Measurement

During the measurement, the LCD real-time display the value of measured current and leakage current, the value displayed on LCD change with different current and leakage current. No measured value reserved when take the meter away from measured wires, LCD display zero.

High voltage, very dangerousOnly qualified personnel

after training could conduct operation on it. The operator should obey safety regulations; Otherwise there will be the danger of electric shock resulting in personal injury or casualty.

Dangerous! Can not be used to test voltage higher than

600V. Otherwise there will be the danger of electric shock resulting in personal injury or casualty.

-8-

Make sure the clamp well closed when measuring leakage current and current.

Make sure the measured wire at approximately the geometric center of the clamp.

Clean the clamp after finishing measurement, regularly maintain the meter.

Clamp live wire and null line together to measure leakage current of electric equipment. (Note: 2 wires)

Clamp earth wire to measure grounding line leakage current of electric equipment. (Note: single wire)

Clamp four wires of there phase to measure the total leakage current. ( Note: 4 wires)

Clamp main line to measure total current of that main line.

(Note: single wire)

Test reference illustrations:

-9-

In HOLD mode, press HOLD key to return back test mode. In data access mode, press HOLD key to exit data access, return back to test mode. In

PEAK mode, press PEAK key to exit PEAK mode, return back to test mode.

After deleting data, it will automatically return back to test mode.

7 PEAK Measurement

The maximum current measurement, during measurement, the meter can automatically compare the changed current, and keep the maximum one.

When take the meter away from the measured wire, the measured value can also be kept, so this mode is suitable for the measurement in places where is not easily to read the value displayed on LCD.

In general test mode, press PEAK key to access or exit PEAK test mode.

“ ” symbol displays in PEAK measurement mode. In other mode, should first exit and return back to test mode, and then operate PEAK measurement as above steps.

IX. Battery Replacement

Warning! Make sure the battery cover is well closed

before measurement, otherwise there will be danger.

Take note of the battery polarity, otherwise it may cause damage to the instrument.

If the battery power is not enough, please change in time.

Take out the batteries if you expect not to use the meter for a long time.

1

.“ ”is displayed when the power voltage is lower than 5.2V, indicating that the battery should be replaced.

2. Press POWER key, make sure the meter is power off. Loosen the battery cover screw, open the plate, replace new batteries and cover the plate, then tighten screw.

-10-

3. Press POWER key to check whether the batteries are successfully replaced, repeat step 2 if it doesn’t work.

XI. Accessories

Main Unit

Meter Box

RS232 Data Line

Disk

Battery

1 piece

1 piece

1 piece

1 piece

4 pieces

(Alkaline Dry Battery LR6)

User Manual

Guarantee Card

Certification

1 piece

1 piece

1 piece

-11-

Manufactured by

ETCR Electronic Technology Company

Address: F-3F, No.4 Pengshang Zhifu Road, Jiahe, Baiyun

District, Guangzhou, Guangdong, China

Post Code: 510440

Tel: (86-20)62199556 62199554

Fax: (86-20)62199550

E-mail: [email protected]

Website: www.etcr.cc