EN

To add optional color change function to ProMix® PD2K Electronic Proportioners. Kits include low or high pressure color/catalyst change valves and a Non-IS or IS control module.

For professional use only.

Important Safety Instructions

Read all warnings and instructions in this manual and in your PD2K proportioner manual. Save these instructions.

See page 4 for model part numbers and approvals information.

PROVEN QUALITY. LEADING TECHNOLOGY.

2

Contents

Related Manuals ................................................ 3

Models............................................................... 4

Non-Intrinsically Safe Kits............................. 4

Intrinsically Safe Kits .................................... 6

Warnings ........................................................... 7

Important Isocyanate (ISO) Information................ 10

Isocyanate Conditions .................................. 10

Material Self-ignition..................................... 10

Keep Components A and B Separate ............ 10

Moisture Sensitivity of Isocyanates................ 10

Changing Materials ...................................... 11

Setup the Modules.............................................. 12

Setup Non-IS Control Modules...................... 12

Setup IS Control Modules............................. 15

Installation.......................................................... 17

Mounting the Color Change Control

Module........................................... 17

Air Supply.................................................... 17

Grounding ................................................... 17

Non-Hazardous Location .............................. 18

Hazardous Location ..................................... 20

Install the Valve Manifolds ............................ 21

Install the Back Pressure Regulator (High

Pressure Systems Only).................. 23

Connect the Valve Air Lines.......................... 23

Connect the Fluid Lines................................ 24

Install an Expansion Kit ................................ 28

Troubleshooting.................................................. 30

Color Change Solenoid Valves ..................... 30

Color Change Board .................................... 32

Electrical Schematics.......................................... 34

Optional Cables and Modules ....................... 40

Repair................................................................ 41

Replace a Color Valve.................................. 41

Replace a Solenoid ...................................... 42

Replace the Color Change Board Fuse ........... 42

Replace the Color Change Board.................. 43

Parts.................................................................. 44

Non-IS Color Change Kits ............................ 45

IS Color Change Kits.................................... 47

Valve Manifolds ........................................... 49

Color Change Control Module Kits ................ 60

Expansion Kits............................................. 64

Dimensions ........................................................ 66

Weights ............................................................. 69

Technical Data ................................................... 73

Graco Standard Warranty.................................... 74

332455E

Related Manuals

Related Manuals

Manual No.

3A2800

332457

332562

3A2801

Description

PD2K Proportioner Repair-Parts

Manual, Manual Systems

PD2K Proportioner Installation

Manual, Manual Systems

PD2K Proportioner Operation

Manual, Manual Systems

Mix Manifold Instructions-Parts

Manual

Manual No.

Description

332339

332454

Pump Repair-Parts Manual

332456

Color Change Valve Repair-Parts

Manual

3rd and 4th Pump Kits

Instructions-Parts Manual

332455E 3

4

Models

Models

Non-Intrinsically Safe Kits

See the module identification label for product part number, maximum air working pressure, and approval information and certification.

Figure 1 Non-Intrinsically Safe Color Change Control

Module Label

Kit No.

24R915

24R916

24R917

24R918

24R919

24R920

24R921

24R922

Series

A

A

A

A

Kit Description Maximum Air Working Pressure

(Control Module)

Maximum Fluid Working

Pressure (Valves)

Low Pressure Non-Circulating Color Change Kits

2 color or 2 catalyst 100 psi (0.7 MPa, 7.0 bar) 300 psi (2.068 MPa, 20.68 bar)

4 color or 4 catalyst 100 psi (0.7 MPa, 7.0 bar)

6 color 100 psi (0.7 MPa, 7.0 bar)

8 color 100 psi (0.7 MPa, 7.0 bar)

Low Pressure Circulating Color Change Kits

300 psi (2.068 MPa, 20.68 bar)

300 psi (2.068 MPa, 20.68 bar)

300 psi (2.068 MPa, 20.68 bar)

A

A

A

A

2 color

4 color

6 color

8 color

100 psi (0.7 MPa, 7.0 bar)

100 psi (0.7 MPa, 7.0 bar)

100 psi (0.7 MPa, 7.0 bar)

100 psi (0.7 MPa, 7.0 bar)

300 psi (2.068 MPa, 20.68 bar)

300 psi (2.068 MPa, 20.68 bar)

300 psi (2.068 MPa, 20.68 bar)

300 psi (2.068 MPa, 20.68 bar)

332455E

Models

Kit No.

24R959

24R960

24R961

24R962

24T579

24T580

24R963

24R964

24R965

24R966

Series

A

A

A

A

Kit Description Maximum Air Working Pressure

(Control Module)

Maximum Fluid Working

Pressure (Valves)

High Pressure Non-Circulating Color Change Kits

2 color or 2 catalyst 100 psi (0.7 MPa, 7.0 bar) 1500 psi (10.34 MPa, 103.4 bar)

4 color or 4 catalyst

6 color

8 color

100 psi (0.7 MPa, 7.0 bar)

100 psi (0.7 MPa, 7.0 bar)

100 psi (0.7 MPa, 7.0 bar)

1500 psi (10.34 MPa, 103.4 bar)

1500 psi (10.34 MPa, 103.4 bar)

1500 psi (10.34 MPa, 103.4 bar)

High Pressure Acid Compatible Non-Circulating Catalyst Change Kits

A

A

2 catalyst (acid compatible)

4 catalyst (acid compatible)

100 psi (0.7 MPa, 7.0 bar)

100 psi (0.7 MPa, 7.0 bar)

1500 psi (10.34 MPa, 103.4 bar)

1500 psi (10.34 MPa, 103.4 bar)

A

A

A

A

2 color

4 color

6 color

8 color

High Pressure Circulating Color Change Kits

100 psi (0.7 MPa, 7.0 bar) 1500 psi (10.34 MPa, 103.4 bar)

100 psi (0.7 MPa, 7.0 bar)

100 psi (0.7 MPa, 7.0 bar)

100 psi (0.7 MPa, 7.0 bar)

1500 psi (10.34 MPa, 103.4 bar)

1500 psi (10.34 MPa, 103.4 bar)

1500 psi (10.34 MPa, 103.4 bar)

332455E 5

Models

Intrinsically Safe Kits

See the module identification label for product part number, maximum air working pressure, and approval information and certification.

Figure 2 Intrinsically Safe Color Change Control

Module Label

0359

II 2 G

Kit No.

24T343

24T344

Series Kit Description

A

A

Maximum Air Working Pressure

(Control Module)

Maximum Fluid Working

Pressure (Valves)

Low Pressure Non-Circulating Color Change Kits

2 color or 2 catalyst 100 psi (0.7 MPa, 7.0 bar) 300 psi (2.068 MPa, 20.68 bar)

24T345

24T346

24T347

24T348

24T349

24T350

A

A

A

A

A

A

4 color or 4 catalyst 100 psi (0.7 MPa, 7.0 bar)

6 color

8 color

100 psi (0.7 MPa, 7.0 bar)

100 psi (0.7 MPa, 7.0 bar)

2 color

4 color

6 color

8 color

300 psi (2.068 MPa, 20.68 bar)

300 psi (2.068 MPa, 20.68 bar)

300 psi (2.068 MPa, 20.68 bar)

Low Pressure Circulating Color Change Kits

100 psi (0.7 MPa, 7.0 bar) 300 psi (2.068 MPa, 20.68 bar)

100 psi (0.7 MPa, 7.0 bar)

100 psi (0.7 MPa, 7.0 bar)

100 psi (0.7 MPa, 7.0 bar)

300 psi (2.068 MPa, 20.68 bar)

300 psi (2.068 MPa, 20.68 bar)

300 psi (2.068 MPa, 20.68 bar)

High Pressure Non-Circulating Color Change Kits

24T351

24T352

24T353

24T354

A

A

A

A

2 color or 2 catalyst 100 psi (0.7 MPa, 7.0 bar)

4 color or 4 catalyst 100 psi (0.7 MPa, 7.0 bar)

6 color

8 color

100 psi (0.7 MPa, 7.0 bar)

100 psi (0.7 MPa, 7.0 bar)

1500 psi (10.34 MPa, 103.4 bar)

1500 psi (10.34 MPa, 103.4 bar)

1500 psi (10.34 MPa, 103.4 bar)

1500 psi (10.34 MPa, 103.4 bar)

24T355

24T356

24T357

24T358

A

A

A

A

2 color

4 color

6 color

8 color

High Pressure Circulating Color Change Kits

100 psi (0.7 MPa, 7.0 bar) 1500 psi (10.34 MPa, 103.4 bar)

100 psi (0.7 MPa, 7.0 bar)

100 psi (0.7 MPa, 7.0 bar)

100 psi (0.7 MPa, 7.0 bar)

1500 psi (10.34 MPa, 103.4 bar)

1500 psi (10.34 MPa, 103.4 bar)

1500 psi (10.34 MPa, 103.4 bar)

6 332455E

Warnings

Warnings

The following warnings are for the setup, use, grounding, maintenance and repair of this equipment. The exclamation point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risks. When these symbols appear in the body of this manual or on warning labels, refer back to these

Warnings. Product-specific hazard symbols and warnings not covered in this section may appear throughout the body of this manual where applicable.

WARNING

FIRE AND EXPLOSION HAZARD

Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent fire and explosion:

• Use equipment only in well ventilated area.

• Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and plastic drop cloths (potential static arc).

• Keep work area free of debris, including solvent, rags and gasoline.

• Do not plug or unplug power cords, or turn power or light switches on or off when flammable fumes are present.

• Ground all equipment in the work area. See Grounding instructions.

• Use only grounded hoses.

• Hold gun firmly to side of grounded pail when triggering into pail. Do not use pail liners unless they are antistatic or conductive.

• Stop operation immediately if static sparking occurs or you feel a shock, Do not use equipment until you identify and correct the problem.

• Keep a working fire extinguisher in the work area.

ELECTRIC SHOCK HAZARD

This equipment must be grounded. Improper grounding, setup, or usage of the system can cause electric shock.

• Turn off and disconnect power at main switch before disconnecting any cables and before servicing or installing equipment.

• Connect only to grounded power source.

• All electrical wiring must be done by a qualified electrician and comply with all local codes and regulations.

332455E 7

8

Warnings

WARNING

INTRINSIC SAFETY

Intrinsically safe equipment that is installed improperly or connected to non-intrinsically safe equipment will create a hazardous condition and can cause fire, explosion, or electric shock.

Follow local regulations and the following safety requirements.

• Be sure your installation complies with national, state, and local codes for the installation of electrical apparatus in a Class I, Group D, Division 1 (North America) or Class I, Zones 1 and 2 (Europe) Hazardous Location, including all of the local safety fire codes (for example,

NFPA 33, NEC 500 and 516, OSHA 1910.107, etc.).

• To help prevent fire and explosion:

• Do not install equipment approved only for a non-hazardous location in a hazardous location. See model ID label for the intrinsic safety rating of your model.

• Do not substitute system components as this may impair intrinsic safety.

• Equipment that comes in contact with the intrinsically safe terminals must be rated for Intrinsic

Safety. This includes DC voltage meters, ohmmeters, cables, and connections. Remove the unit from the hazardous area when troubleshooting.

SKIN INJECTION HAZARD

High-pressure fluid from gun, hose leaks, or ruptured components will pierce skin. This may look like just a cut, but it is a serious injury that can result in amputation. Get immediate surgical treatment.

• Do not spray without tip guard and trigger guard installed.

• Engage trigger lock when not spraying.

• Do not point gun at anyone or at any part of the body.

• Do not put your hand over the spray tip.

• Do not stop or deflect leaks with your hand, body, glove, or rag.

• Follow the Pressure Relief Procedure when you stop spraying/dispensing and before cleaning, checking, or servicing equipment.

• Tighten all fluid connections before operating the equipment.

• Check hoses and couplings daily. Replace worn or damaged parts immediately.

MOVING PARTS HAZARD

Moving parts can pinch, cut or amputate fingers and other body parts.

• Keep clear of moving parts.

• Do not operate equipment with protective guards or covers removed.

• Pressurized equipment can start without warning. Before checking, moving, or servicing equipment, follow the Pressure Relief Procedure and disconnect all power sources.

TOXIC FLUID OR FUMES

Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled, or swallowed.

• Read MSDSs to know the specific hazards of the fluids you are using.

• Store hazardous fluid in approved containers, and dispose of it according to applicable guidelines.

• Always wear chemically impermeable gloves when spraying, dispensing, or cleaning equipment.

332455E

332455E

Warnings

WARNING

PERSONAL PROTECTIVE EQUIPMENT

Wear appropriate protective equipment when in the work area to help prevent serious injury, including eye injury, hearing loss, inhalation of toxic fumes, and burns. This protective equipment includes but is not limited to:

• Protective eyewear, and hearing protection.

• Respirators, protective clothing, and gloves as recommended by the fluid and solvent manufacturer.

EQUIPMENT MISUSE HAZARD

Misuse can cause death or serious injury.

• Do not operate the unit when fatigued or under the influence of drugs or alcohol.

• Do not exceed the maximum working pressure or temperature rating of the lowest rated system component. See Technical Data in all equipment manuals.

• Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in all equipment manuals. Read fluid and solvent manufacturer’s warnings. For complete information about your material, request MSDS from distributor or retailer.

• Do not leave the work area while equipment is energized or under pressure.

• Turn off all equipment and follow the Pressure Relief Procedure when equipment is not in use.

• Check equipment daily. Repair or replace worn or damaged parts immediately with genuine manufacturer’s replacement parts only.

• Do not alter or modify equipment. Alterations or modifications may void agency approvals and create safety hazards.

• Make sure all equipment is rated and approved for the environment in which you are using it.

• Use equipment only for its intended purpose. Call your distributor for information.

• Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.

• Do not kink or over bend hoses or use hoses to pull equipment.

• Keep children and animals away from work area.

• Comply with all applicable safety regulations.

9

Important Isocyanate (ISO) Information

Important Isocyanate (ISO) Information

Isocyanates (ISO) are catalysts used in two component materials.

Isocyanate Conditions

Keep Components A and B Separate

Spraying or dispensing materials containing isocyanates creates potentially harmful mists, vapors, and atomized particulates.

Read material manufacturer’s warnings and material MSDS to know specific hazards and precautions related to isocyanates.

Prevent inhalation of isocyanate mists, vapors, and atomized particulates by providing sufficient ventilation in the work area. If sufficient ventilation is not available, a supplied-air respirator is required for everyone in the work area.

To prevent contact with isocyanates, appropriate personal protective equipment, including chemically impermeable gloves, boots, aprons, and goggles, is also required for everyone in the work area.

Material Self-ignition

Some materials may become self-igniting if applied too thick. Read material manufacturer’s warnings and material MSDS.

10

Cross-contamination can result in cured material in fluid lines which could cause serious injury or damage equipment. To prevent cross-contamination:

• Never interchange component A and component

B wetted parts.

• Never use solvent on one side if it has been contaminated from the other side.

Moisture Sensitivity of Isocyanates

Exposure to moisture (such as humidity) will cause

ISO to partially cure; forming small, hard, abrasive crystals, which become suspended in the fluid.

Eventually a film will form on the surface and the ISO will begin to gel, increasing in viscosity.

NOTICE

Partially cured ISO will reduce performance and the life of all wetted parts.

• Always use a sealed container with a desiccant dryer in the vent, or a nitrogen atmosphere.

Never store ISO in an open container.

• Keep the ISO pump wet cup or reservoir (if installed) filled with appropriate lubricant. The lubricant creates a barrier between the ISO and the atmosphere.

• Use only moisture-proof hoses compatible with

ISO.

• Never use reclaimed solvents, which may contain moisture. Always keep solvent containers closed when not in use.

• Always lubricate threaded parts with an appropriate lubricant when reassembling.

NOTE: The amount of film formation and rate of crystallization varies depending on the blend of ISO, the humidity, and the temperature.

332455E

Changing Materials

NOTICE

Changing the material types used in your equipment requires special attention to avoid equipment damage and downtime.

• When changing materials, flush the equipment multiple times to ensure it is thoroughly clean.

• Always clean the fluid inlet strainers after flushing.

• Check with your material manufacturer for chemical compatibility.

• When changing between epoxies and urethanes or polyureas, disassemble and clean all fluid components and change hoses. Epoxies often have amines on the B (hardener) side. Polyureas often have amines on the A (resin) side.

Important Isocyanate (ISO) Information

332455E 11

Setup the Modules

Setup the Modules

Setup Non-IS Control Modules

NOTE: The PD2K System can use up to four pumps and six color change modules in the non-hazardous area. Use the following table to understand how many color change modules are needed for the number of pumps in your system, and which module should be associated to which pump.

All Non-IS modules ship from the factory as Module

1 (Colors 1–8). Labels for Modules 2 through 6 are provided with the module kit. Affix the labels according to your system configuration.

Table 1 . Relationship of Non-IS Color Change Control Modules to Pumps

System Pump Configuration

Color

Pump(s)

Catalyst

Pump(s)

Total

Pumps

1

1

2

2

2

3

3

4

0

1

1

0

2

1

0

0

1

2

3

2

4

4

3

4

Module 1

(Colors

1–8)

Pump # 1

Color Change Control Modules, Colors, and Catalysts

Module 2

(Colors

9–16)

Pump # 1

Pump # 2

Module

3 (Colors

17–24)

Pump # 1

Pump # 3

Module 4

(Colors

25–30)

Pump # 1

Pump # 3

Pump # 4

Catalyst

1–2

Catalyst

3–4

Not Applicable

Module # 5

Pump # 2

Module # 5

Pump # 2

Not Applicable

Module

# 5

Pump # 2

Module

# 6

Pump # 4

Module # 5

Pump # 2

Not Applicable

Not Applicable

12 332455E

Setup the Modules

Configure each module according to its designated number, as follows:

NOTICE

To avoid damaging the circuit boards, wear Part

No. 112190 grounding strap on your wrist and ground appropriately.

To avoid electrical component damage, remove all system power before plugging any connectors.

1. Remove electrical power from the system.

2. Open the color change module. Locate switches

S4, S5, and S6 on the control module board. The switches are shipped in the OFF position.

3. For each module, set the switches to ON or OFF, as shown in the following table.

Inlet Manifold

Non-IS Control Module Switch Settings

Control

Module

S6 S5 S4

Module 1

ON ON ON

Module 2

OFF

ON

OFF

ON

OFF

ON

Module 3

OFF

ON

OFF

ON

OFF

ON

Module 4

OFF

ON

OFF

ON

OFF

ON

Module 5

OFF

ON

OFF

ON

OFF

ON

Module 6

OFF

ON

OFF

ON

OFF

ON

OFF OFF OFF

4. Use the following figure and tables to determine the solenoid valve assigned to each valve in the valve manifold.

NOTE: There can be only one solvent valve and one dump valve per pump.

Outlet Manifold

Figure 3 Non-IS Control Module

332455E 13

Setup the Modules

8

9

6

7

4

5

2

3

Non-IS Control Module 1

Inlet Manifold Outlet Manifold

Solenoid

1

Valve

Solvent

Solenoid

1

Valve

Dump

Color 1

Color 2

Color 3

Color 4

2

3

4

5

Color 1

Color 2

Color 3

Color 4

Color 5

Color 6

Color 7

Color 8

8

9

6

7

Color 5

Color 6

Color 7

Color 8

6

7

4

5

8

9

Non-IS Control Module 2

Inlet Manifold

Solenoid Valve

1

2

(Solvent)*

Color 9

1

2

3 Color 10

Outlet Manifold

Solenoid Valve

3

(Dump)*

Color 9

Color 10

Color 11

Color 12

Color 13

Color 14

Color 15

Color 16

4

5

6

7

8

9

Color 11

Color 12

Color 13

Color 14

Color 15

Color 16

8

9

6

7

4

5

2

3

4

5

6

7

2

3

Non-IS Control Module 4

Inlet Manifold Outlet Manifold

Solenoid

1

Valve

(Solvent)*

Solenoid

1

Valve

(Dump)*

Solenoid

1

8

9

Color 25

Color 26

Color 27

Color 28

Color 29

Color 30

Not Used 8

Not Used 9

Non-IS Control Module 5

Inlet Manifold Outlet Manifold

Valve

(Solvent)*

Catalyst 1

Catalyst 2

Catalyst 3

Catalyst 4

Not Used

Not Used

2

3

4

5

6

7

Solenoid

1

2

3

4

5

Not Used 6

Not Used 7

8

9

Color 25

Color 26

Color 27

Color 28

Color 29

Color 30

Not Used

Not Used

Valve

(Dump)*

Catalyst 1

Catalyst 2

Catalyst 3

Catalyst 4

Not Used

Not Used

Not Used

Not Used

8

9

6

7

2

3

4

5

Non-IS Control Module 3

Inlet Manifold Outlet Manifold

Solenoid

1

Valve

(Solvent)*

Solenoid

1

Valve

(Dump)*

Color 17

Color 18

Color 19

Color 20

2

3

4

5

Color 17

Color 18

Color 19

Color 20

Color 21

Color 22

Color 23

Color 24

8

9

6

7

Color 21

Color 22

Color 23

Color 24

2

3

4

5

Solenoid

1

6

7

8

9

Non-IS Control Module 6

Inlet Manifold Outlet Manifold

Valve

(Solvent)*

Catalyst 3

Catalyst 4

Not Used

Not Used

* There should be only one solvent valve and one dump valve per pump.

Solenoid

1

2

3

4

5

Not Used 6

Not Used 7

Not Used 8

Not Used 9

Valve

(Dump)*

Catalyst 3

Catalyst 4

Not Used

Not Used

Not Used

Not Used

Not Used

Not Used

14 332455E

Setup the Modules

Setup IS Control Modules

NOTE: Two color change control modules may be installed in the hazardous area. The modules are numbered 7 and 8. All IS modules ship from the factory as Module 7 (Colors 1–12 and Catalysts 1–4).

A label for Module 8 (Colors 13–30) is provided with the module kit. Affix the label according to your system configuration.

Configure each module according to its designated number, as follows:

NOTICE

To avoid damaging the circuit boards, wear Part

No. 112190 grounding strap on your wrist and ground appropriately.

To avoid electrical component damage, remove all system power before plugging any connectors.

1. Remove electrical power from the system.

2. Open the color change module. Locate switches

S4, S5, and S6 on the control module board. The switches are shipped in the OFF position.

3. For each module, set the switches to ON or OFF, as shown in the following table.

Control

Module

IS Control Module Switch Settings

S6 S5 S4

Module 7

ON ON ON

Module 8

OFF

ON

OFF

ON

OFF

ON

OFF OFF OFF

4. Use the following figure and tables to determine the solenoid valve assigned to each valve in the valve manifold.

Figure 4 IS Control Module

332455E 15

Setup the Modules

8

9

6

7

4

5

2

3

Solenoid

1

IS Control Module 7

Valve Solenoid

Color

Solvent

1

Color 1

Color 2

Color 3

Color 4

2

3

4

5

Color 5

Color 6

Color 7

Color 8

8

9

6

7

Valve

Catalyst

Solvent

Catalyst 1

Catalyst 2

Catalyst 3

Catalyst 4

Color 9

Color 10

Color 11

Color 12

8

9

6

7

4

5

2

3

IS Control Module 8

Inlet Manifold Outlet Manifold

Solenoid

1

Valve

Color 13

Solenoid

1

Valve

Color 22

Color 14

Color 15

Color 16

Color 17

2

3

4

5

Color 23

Color 24

Color 25

Color 26

Color 18

Color 19

Color 20

Color 21

8

9

6

7

Color 27

Color 28

Color 29

Color 30

16 332455E

Installation

Installation

• To avoid electric shock, turn off power at the main circuit breaker before opening the enclosure.

• All electrical wiring must be done by a qualified electrician and comply with all local codes and regulations.

• Do not substitute or modify system components as this may impair intrinsic safety.

• Do not install equipment approved only for non-hazardous location in a hazardous location.

See the identification label for the intrinsic safety rating for your model.

3. Using the equipment as a template, mark the mounting holes on the wall at a convenient height for the operator and so the equipment is easily accessible for maintenance.

4. Drill mounting holes in the wall. Install anchors as needed.

5. Bolt the equipment securely.

Air Supply

Connect a clean and dry air supply to the color change control module air inlet fitting (317); the fitting is for 1/4 in. (6 mm) OD tubing. Use a 5 micron filter.

Regulate the air pressure to 85–100 psi (0.6–0.7

MPa, 6.0–7.0 bar).

Grounding

This equipment stays pressurized until pressure is manually relieved. To help prevent serious injury from pressurized fluid, such as skin injection, splashing fluid and moving parts, follow the

Pressure Relief Procedure in the PD2K Operation

Manual before installing the kit.

Mounting the Color Change Control

Module

1. See

Dimensions, page 66

.

2. Ensure that the wall and mounting hardware are strong enough to support the weight of the equipment, fluid, hoses, and stress cause during operation.

This equipment must be grounded to reduce the risk of static sparking and electric shock. Electric or static sparking can cause fumes to ignite or explode. Improper grounding can cause electric shock. Grounding provides an escape wire for the electric current.

Connect a ground wire from the color change module to a true earth ground.

Intrinsically safe color change modules located in the hazardous area must be connected to a true earth ground in the hazardous area.

332455E 17

Installation

Non-Hazardous Location

NOTE: Non-IS color change control modules provide control for the pump’s inlet and outlet color/catalyst change valves. Depending on the number of valves in the system, as many as six control modules may be installed in the non-hazardous location.

1. Mount the first non-IS color control module as described in

Mounting the Color Change Control

Module, page 17 .

2. Connect the 5–pin CAN cable (109) to J7 on the color control module (108).

page 17 . Connect a 5–pin CAN cable from J11

of the previous color control module to J7 of the next control module.

8. Replace the cover of the PD2K electrical control box before turning on power to the system.

Figure 5 Cable Connector J7 at Non-IS Color

Control Module

NOTICE

To avoid damaging the circuit boards, wear

Part No. 112190 grounding strap on your wrist and ground appropriately.

To avoid electrical component damage, remove all system power before plugging any connectors.

3. Remove electrical power from the system.

4. Remove the cover from the PD2K electrical control box.

5. Install the supplied 2–cable grommet (110) on the cable (109) and secure the grommet to the side of the electrical control box.

6. Connect the cable (109) to J2 on the non-IS side of the isolation board inside the electrical control box. See

Electrical Schematics, page 34

for a list of M12 CAN cables for use in a non-hazardous area.

7. To install additional color control modules (six maximum), mount the module(s) as described in

Mounting the Color Change Control Module,

Figure 6 Cable Connection at PD2K Electrical

Control Box

Figure 7 Detail of Isolation Board Cable Connections

18 332455E

Notes

Installation

332455E 19

Installation

Hazardous Location

NOTE: IS color change control modules provide control for color/catalyst change valves located in the hazardous location. A maximum of two IS control modules may be installed in the hazardous location.

See

IS Color Change Control Modules, page 62

for a list of modules approved for installation in a hazardous location.

NOTICE

To avoid damaging the circuit boards, wear Part

No. 112190 grounding strap on your wrist and ground appropriately.

To avoid electrical component damage, remove all system power before plugging any connectors.

Only approved cables may be used in the hazardous location. Hazardous location cables are marked with a light blue flag next to each connector.

See

Optional Cables and Modules, page 40

for a list of M12 CAN cables for use in a hazardous area.

1. Remove electrical power from the system.

2. Mount the first color control module as described in

Mounting the Color Change Control Module, page 17 .

NOTE: If your system includes a booth control

(BC), disconnect the booth control from the hazardous location cable (C1).

3. Connect the hazardous location cable (C1) to J7 on the color control module (108).

Figure 9 Cable Connectors J7 and J11 at IS

Color Control Module

NOTE: If your system includes a booth control

(BC), the cable (C1) is already attached to the isolation board in the electrical control box. Skip step 4 and go to step 5.

4. Remove the cover from the PD2K electrical control box. Install the grommet (G) on the supplied cable (C1) and secure the grommet to the side of the electrical control box. Locate

J4 on the IS side of the isolation board in the electrical control box. Connect the cable (C1) to

J4. See

Electrical Schematics, page 34

.

20

Figure 8 Intrinsically Safe Cable Connections

Figure 10 Detail of Isolation Board Cable

Connections

332455E

Installation

5. If your system includes a second color control module and/or a booth control, they must be connected in the following order. The booth control must be the last component in the series.

• Mount a second color control module as described in

Mounting the Color Change

Control Module, page 17

. Connect the supplied hazardous location cable (C2) from

J11 on the first color control module to J7 on the second module.

• Mount the booth control (BC) as described in your PD2K installation manual. Connect the supplied hazardous location cable (C2) from

J11 on the final color control module to the

CAN cable connector on the bottom of the booth control.

6. Replace the cover of the PD2K electrical control box before turning on power to the system.

2. Install the inlet and outlet valve manifolds (102) on the mounting bracket (101) with four screws

(104), washers (105), and nuts (106).

NOTE: On low pressure systems, the supplied bracket (101) will accommodate a manifold with 16 valve positions (14 colors). On high pressure systems, the supplied bracket (101) will accommodate a manifold with 14 valve positions

(12 colors). A larger valve stack will require a customer supplied/sourced bracket.

3. Repeat for the opposite side of the PD2K.

4. Connect the air lines from the solenoids to the valves. See

Connect the Valve Air Lines, page 23 .

NOTE: On high pressure systems, see

Install the Back Pressure Regulator (High

Pressure Systems Only), page 23 .

5. Connect the fluid supply lines to the valves. See

Connect the Fluid Lines, page 24

.

Install the Valve Manifolds

NOTE: Always label the color connections to prevent cross-connections. Label the inlet manifold, outlet manifold, and each color valve with its assigned color.

The solvent and dump valves should be furthest from the manifold stack primary inlet or outlet.

1. Install a mounting bracket (101) on the PD2K with four screws (103). High pressure systems:For stability, be sure to fasten the bottom screws

(103) to the pump bracket.

Figure 11 Install the Valve Manifolds

332455E 21

Installation

Notes

22 332455E

Installation

Install the Back Pressure Regulator

(High Pressure Systems Only)

NOTE: The back pressure regulator is required on high pressure systems to prevent the system’s feed pumps from overdriving the dosing pumps during color change pump flush and color fill operations.

Adjust the back pressure during the dump process to be approximately 75% of the supply pressure from the feed pumps, but never more than 300 psi (2.1

MPa, 21 bar) less than the supply pressure.

Install the back pressure regulator (120) and attaching hardware at the dump valve of the outlet manifold stack.

1. Screw the tee (122) onto the dump valve fitting of the outlet manifold stack.

2. Assemble the two nipples (121) to the back pressure regulator (120). Screw the regulator assembly into the tee (122) as shown.

3. Install the gauge (123) in the open port of the tee (122).

4. Connect a 1/4 npt(f) dump line to the downward facing nipple (121).

5. Connect the fluid supply lines to the valves. See

Connect the Fluid Lines, page 24

.

Figure 12 Install Back Pressure Regulator at Dump

Valve of Outlet Stack

Connect the Valve Air Lines

1. Connect 5/32 in. (4 mm) OD air tubes from the inlet solenoids to the air inlets of each inlet valve, using the label inside the color control module as a guide. See

Setup the Modules, page 12 .

2. Repeat for the outlet valves.

332455E 23

Installation

Connect the Fluid Lines

Connect Non-Circulating Fluid Lines

NOTE: There can be only one solvent valve (S) and one dump valve (D) per pump.

NOTE: On high pressure systems, see

Install the Back Pressure Regulator (High Pressure

Systems Only), page 23 .

1. Use the top valve of the inlet valve stack as the solvent valve (S). Connect a solvent supply line to the 1/4 npt(m) solvent valve inlet on the color and catalyst valve stacks.

INLET COLOR VALVE STACK

2. Use the top valve of the outlet valve stack as the dump valve (D). Connect a waste dump line to the 1/4 npt(m) dump valve outlet on the color and catalyst valve stacks.

3. Connect the supply line for each color to the corresponding color valve fitting (C1, C2, etc.) on the inlet color valve stack.

4. Connect a supply line from the bottom fitting of the inlet color valve stack to the inlet manifold of the material A dosing pump.

5. Connect a supply line from the outlet manifold of the material A dosing pump to the bottom fitting of the outlet color valve stack.

OUTLET COLOR VALVE STACK

Valve Manifold Stack Schematic

24 332455E

Installation

6. Connect a dedicated gun supply line for each color to the corresponding color valve fitting (C1,

C2, etc.) on the outlet color valve stack. Connect the other end of this line to the A side of the mix manifold at the gun.

7. Connect the supply line for each catalyst to the corresponding catalyst valve fitting on the inlet catalyst valve stack.

8. Connect a supply line from the bottom fitting of the inlet catalyst valve stack to the inlet manifold of the material B dosing pump.

9. Connect a supply line from the outlet manifold of the material B dosing pump to the bottom fitting of the outlet catalyst valve stack.

10. Connect a dedicated gun supply line for each catalyst to the corresponding catalyst valve fitting on the outlet catalyst valve stack. Connect the other end of this line to the B side of the mix manifold at the gun.

NOTE: If your system uses more colors than catalysts, branch the catalyst line to connect it to each mix manifold. Install a check valve on each branch of the catalyst line.

NOTE: For ease of maintenance, install a ball valve at all fluid line tees.

11. The mix manifold is belt-mounted. Connect a fluid hose between the manifold outlet and the gun inlet.

Figure 13 Color Change Connections

(Non-Circulating System)

KEY

A

W

S

C1

C2

Air inlet

Seal weep and lubrication port

Solvent fitting

Color 1 fitting

Color 2 fitting

332455E 25

Installation

Connect Circulating Fluid Lines

Circulation valves enable constant circulation of a color when that color is not being sprayed:

• When a color valve is closed, the system bypasses the dosing pump by directing that color from the inlet color valve to the outlet color valve through a circulation line, then to a Y fitting at the mix manifold, then back to the color supply.

• When a color valve is open, the circulation line is shut off. The color is directed through the material

A dosing pump and out to the gun to be mixed and sprayed, as in normal operation.

NOTE: On circulating systems, install a cap (T) on any unused valve fittings.

NOTE: There can be only one solvent valve (S) and one dump valve (D) per pump.

NOTE: On high pressure systems, see

Install the Back Pressure Regulator (High Pressure

Systems Only), page 23 .

1. Connect all fluid lines as described in

Connect Non-Circulating Fluid Lines, page 24 .

These lines are used during normal mixing and spraying.

2. Connect the circulation lines as follows: a. Connect a 1/4 npt(f) circulation line for each color from the color valve’s circulation fitting

(R1, R2, etc.) on the inlet color valve stack

(B) to the corresponding circulation fitting

(R1, R2, etc.) on the outlet color valve stack (C). This circulation line bypasses the material A dosing pump when the color valve is closed, allowing continuous circulation of that color.

b. Install a Y fitting (D) in the A side of the mix manifold (F). Install a fluid shutoff valve (E) in one branch of the Y fitting. Connect a fluid return line (H) to the shutoff valve, to circulate the color back to the color supply (A).

NOTE: The fluid shutoff valve (E) must be closed when spraying, to allow proper ratio mixing and flow from the gun (G).

c. Connect a dedicated gun supply line for each color to the corresponding color valve

(C1, C2, etc.) on the outlet color valve stack.

Connect the other end of this line to the open branch of the Y fitting (D).

Figure 14 Valve Manifold Connections (Circulating

System)

C2

R1

R2

KEY

T

S

C1

Cap any unused fittings

Solvent fitting

Color 1 fitting

Color 2 fitting

Color 1 circulation fitting

Color 2 circulation fitting

26 332455E

Installation

B

C

D

KEY

A

Fluid Flow Schematic Diagram in Circulating Mode (Pump Not Shown for Clarity)

Color supply

Inlet color stack

Outlet color stack

Y fitting at mix manifold

A port

F

G

KEY

E

H

Fluid shutoff valve

Mix manifold

Spray gun

Return line to fluid supply

332455E 27

Installation

Install an Expansion Kit

Expansion Kits are available to add valves or manifolds to your system. See

Expansion Kits, page 64

for available kits.

1. Remove electrical power from the system.

2. Relieve pressure as described in your PD2K

Operation Manual.

3. Open the control module cover. Install the solenoid(s) and air fitting(s) at the appropriate position(s) in the solenoid manifold. See

Setup the Modules, page 12 . Connect one end

of the tubing to the solenoid’s air fitting.

4. Connect the solenoid wires to the appropriate pins on the control module board. See

Electrical Schematics, page 34

.

NOTE: If installing a one valve kit, it is not necessary to disassemble the manifold stack as shown in the figure. Skip step 5 and go on to step 6.

5. If your kit is adding a manifold block (1), remove the screws (10). Slide the existing manifolds off the rods (15, 16), keeping the manifolds in the correct order. Install the new manifold block (1).

The new block must be in the bottom position to maintain correct location of the solvent and dump valves. Screw the rods (16) included in the kit into the existing rods. Slide the existing manifold blocks onto the rods, being sure that they are in the same positions as before. Ensure all o-rings

(6, 17) are in place, then install the screws (10).

6. Install the valves as follows: a. For a one valve kit, remove the plug

(4) and o-ring (2). Install a new o-ring

(2), the valve (3), and retainer (5), using the valve installation tool. See

Replace a Color Valve, page 41

.

b. For a manifold kit with one valve, install the o-ring (2), valve (3), and retainer (5), using the valve installation tool. See

Replace a Color Valve, page 41 . Install the

plug (4) in the unused manifold port.

c. For a manifold kit with two valves, install the o-rings (2), valves (3), and retainers

(5), using the valve installation tool. See

Replace a Color Valve, page 41

.

7. Install the o-ring(s) (12) and fluid fitting(s) (13).

Connect fluid lines to the fittings.

8. Install the air fitting(s) (14). Connect the tubing from the solenoid valve(s) (see step 3) to the fitting(s).

9. Install the control module cover.

10. Return the unit to service.

28 332455E

Installation

Figure 15 Install an Expansion Kit (Low Pressure

Valve Manifold Shown)

332455E 29

Troubleshooting

Troubleshooting

NOTE: Check all possible remedies before disassembling the system.

Color Change Solenoid Valves

NOTE: Refer to

Electrical Schematics, page 34 . If the color change valves are not turning on or off correctly, it

could be caused by one of the following.

Cause

1. Air regulator pressure set too high or too low.

2. Air or electrical lines damaged or connections are loose.

3. Solenoid failure.

Solution

Check that air pressure is at least 85 psi (0.6 MPa, 6.0 bar). Do not go above 100 psi (0.7 MPa, 7.0 bar).

Visually inspect air and electrical lines for kinks, damage, or loose connections.

Service or replace as needed.

Check the applicable solenoid’s LED; see

Color Change Board, page 32 . If lit,

proceed with the following checks. If not lit, go to Cause 4.

Remove the connector for the applicable solenoid and measure voltage across the pins on the board:

• In a non-hazardous location, replace the solenoid if voltage is 24 Vdc.

• In a hazardous location, replace the solenoid if voltage is between 9–15 Vdc.

Test the valves as explained under Maintenance Screen 4 in your PD2K

Operation manual. Valves should open and close quickly. If the valves actuate slowly, it could be caused by:

• Air pressure to the valve actuators is too low. See Cause 1.

• Solenoid is clogged. Make sure the air supply has a 5 micron filter installed.

• Something is restricting the solenoid or tubing. Check for air output from the air line for the corresponding solenoid when the valve is actuated. Clear the restriction.

30 332455E

Troubleshooting

Cause

4. Control board or cable failure.

Solution

If there is no voltage across the pins on the board or it is less than 9 Vdc, check

LEDs D8, D9, and D10. If they are lit and functioning properly, or other solenoids in the module are working properly, replace the color change board.

If D9 is not lit:

• Verify the condition of the fuse (F1) and replace if necessary. See

Replace the Color Change Board Fuse, page 42

.

• Check if the cable is disconnected or damaged.

• Check the isolation board. See the PD2K Repair-Parts manual.

If D8 is not blinking:

• Cycle the system power.

• Check if the cable is disconnected or damaged.

• Check the isolation board. See the PD2K Repair-Parts manual.

If D10 is not occasionally blinking:

• Check if the cable is disconnected or damaged.

• Check the isolation board. See the PD2K Repair-Parts manual.

332455E 31

Troubleshooting

Color Change Board

NOTICE

To avoid damaging the circuit boards, wear Part

No. 112190 grounding strap on your wrist and ground appropriately.

To avoid electrical component damage, remove all system power before plugging any connectors.

Figure 16 Color Change Board

32 332455E

Color Change Board Diagnostics

Component or

Indicator

D8

D9

Description

LED (green)

LED (green)

D10 LED (yellow)

D27–D39,

D41, D43–D46

F1

LED (green)

Fuse, 0.125 A, 125 V

Troubleshooting

Diagnosis

Blinks (heartbeat) during normal operation.

Turns on when power is supplied to the board.

Turns on when board is communicating with electronic control.

Turn on when a signal is sent to actuate the related solenoid valve.

332455E 33

Electrical Schematics

Electrical Schematics

NOTE: The electrical schematic illustrates all possible wiring expansions in a ProMix PD2K system. Some components shown are not included with all systems.

NOTE: See

Optional Cables and Modules, page 40

, for a list of cable options.

FAN

(24P658)

ENCODER AND MOTOR

(16P036, 16P037)

WIRE HARNESS

(24P684, 24P685)

PUMP INLET

TRANSDUCER

(16P289, 16P290)

PUMP OUTLET

TRANSDUCER

(16P289, 16P290)

PUMP V/P FOR

FLUID REG.

SOLENOID (16P812)

UP

DOWN

FLOW SENSOR

(120278)

OR G3000 METER

(239716, 258718

16M510, 16M519)

2 POSITION

SWITCH

(16U725)

CABLE

16T658

LINE FILTER

(16V446)

CABLE

16H078

TERMINAL BLOCK

(114095)

POWER IN

24V

POWER

SUPPLY

(16T660)

FAN

(24P658)

ENCODER AND MOTOR

(16P036, 16P037)

WIRE HARNESS

(24P684, 24P685)

PUMP INLET

TRANSDUCER

(16P289, 16P290)

PUMP OUTLET

TRANSDUCER

(16P289, 16P290)

PUMP V/P FOR

FLUID REG.

SOLENOID (16P812)

UP

DOWN

FLOW SENSOR

(120278)

OR G3000 METER

(239716, 258718

16M510, 16M519)

RELAY

POWER MODULE

(24R257)

48V-10A POWER SUPPLY

(16U820)

TERMINAL BLOCKS WITH FUSES

065161, 065159

COMMUNICATION

MODULE

(24R910)

5

CABLE (121227)

COMMUNICATION

MODULE

(24R910)

5

CABLE (121227)

CABLE (121227)

16T072

CAN

IS BOARD

(24M485)

SPLITTER

(16P243)

CABLE (16T280)

BARRIER

BOARD

(248192)

4

CABLE (16T659)

CABLE (16T659)

CABLE (16T659)

CABLE (16T659)

FAN

(24P658)

ENCODER AND MOTOR

(16P036, 16P037)

WIRE HARNESS

(24P684, 24P685)

PUMP INLET

TRANSDUCER

(16P289, 16P290)

PUMP OUTLET

TRANSDUCER

(16P289, 16P290)

PUMP V/P FOR

FLUID REG.

FAN

(24P658)

ENCODER AND MOTOR

(16P036, 16P037)

WIRE HARNESS

(24P684, 24P685)

PUMP INLET

TRANSDUCER

(16P289, 16P290)

PUMP OUTLET

TRANSDUCER

(16P289, 16P290)

PUMP V/P FOR

FLUID REG.

SOLENOID (16P812)

UP

DOWN

SOLENOID (16P812)

UP

DOWN

FLOW SENSOR

(120278)

OR G3000 METER

(239716, 258718

16M510, 16M519)

FLOW SENSOR

(120278)

OR G3000 METER

(239716, 258718

16M510, 16M519)

Figure 17 Electrical Schematic, Sheet 1

2

CABLE

(15V206)

2 CABLE

(15V206)

MODULE 1 (24N935)

2

CABLE

(15V206)

MODULE 2 (24N935) MODULE 3 (24N935)

2

CABLE

(15V206)

MODULE 4 (24N935) MODULE 5 (24N935)

2

CABLE

(15V206)

MODULE 6 (24N935)

GCA

MODULE

EFCM

(24N913)

GUN TRIGGER INPUTS

119159

119159

119159

119159

SOLENOID (121324)

PRESSURE SWITCH

(121323)

SOLVENT FLOW SWITCH (120278)

SOLVENT METER (258718)

3

CABLE

(121003)

ADVANCED

DISPLAY MODULE

(24E451)

LIGHT

TOWER

(15X472)

1 CABLE (16V429) CABLE (16V426)

COLOR CHANGE MODULE 7

(24R219)

7

COLOR CHANGE MODULE 8

(24R219)

7

BOOTH CONTROL (24M731)

HAZARDOUS LOCATION

NON-HAZARDOUS LOCATION

CABLE (16V426)

34 332455E

Electrical Schematics

SPLITTER

(16P243)

5 4 3 2 1

UNUSED UNUSED UNUSED

CONTINUED ON PAGE 3 CONTINUED ON PAGE 3

1 2 3 4 5

2

4

1 2 3 4 5

3

CABLE (121227)

2

3

CABLE (15V206)

16T072

1 2 3 4 5

CAN IS BOARD

(NON IS)

(IS)

(24M485)

3

1 2 3 4 5

1

UNUSED

CABLE (16T280)

1 2 3

UNUSED UNUSED

BARRIER

BOARD

(248192)

CABLE

(121227)

3

3

5

SOLVENT CUTOFF

PWR (RED)

SIG (WHITE)

COM (BLACK)

SHIELD/GRN SOLVENT

METER

(258718)

UNUSED

UNUSED

10

UNUSED

CABLE

(121227)

3

+12VDC

COM

UNUSED

UNUSED

+12VDC

COM

+12VDC

COM

UNUSED

8

GCA MODULE

EFCM

(24N913)

1

2

6

7

4

5

8

9

10

12

5

1 2 3 4 5 6 7 8 9 10

1

11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 1 2 3 4 5 6 7 8 9 10

2

11 12 13 14 15 16 17 18 19 20 21 22 23 24 25

RED WIRE (065161)

BLACK WIRE (065159)

GROUND BAR

4

25 PIN D-SUB CABLE

(16T659)

24V

POWER

SUPPLY

(16T660)

L (BROWN) N (BLUE)

N03 N03

2 POSITION

SWITCH

(16U725)

N04 N04

CABLE

(16T658)

L N

LINE

FILTER

(16V446)

L GRND N

CABLE

(16H078)

L N GRND

TERMINAL

BLOCK

(114095)

L N GRND

GRND (GRN/YEL)

13 A1(+) A2(-)

RELAY

14

N L GRND

48V-10A

POWER SUPPLY

+ -

+ - + - + - + -

+ - + - + - + -

DETAIL A, LOW PRESSURE

PUMPS (24M706, 24M714)

2

1 2 3 4 5

BREAKOUT MODULE

(24N527)

3

1 2 3 4

WIRE HARNESS

(24P684) DRAIN/FOIL

1 2 3 4 5 6 7 8

BREAKOUT MODULE PUMP 1 (24N527)

9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25

1

2

1 2 3 4 5

3

1 2 3 4

4

1 2 3 4 5

5

1 2 3 4 5

6

1 2 3 4 1 2 3 4

7

5 6 7 8

8

1 2 3 4

1 2 3 4 5 6 7 8

BREAKOUT MODULE PUMP 2 (24N527)

9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25

1

2

1 2 3 4 5

3

1 2 3 4

4

1 2 3 4 5

5

1 2 3 4 5

6

1 2 3 4 1 2 3 4

7

5 6 7 8

8

1 2 3 4

+48V COM +48V COM

ENCODER/MOTOR

AND

WIRE HARNESS

PUMP 1

SEE DETAIL A OR B

TRANSDUCER PUMP TRANSDUCER PUMP

TWISTED PAIR CABLE (16W159)

PWR (RED) SIG (WHITE) COM (BLACK) SHIELD/GRN

1 UP

MANIFOLD

MAC SERIES 46 (16P812 QTY

G3000

METER

PUMP 1

(EITHER, 239716,

258718,16M510,

OR 16M519)

GRND

SCREW

+48V COM +48V COM

ENCODER/MOTOR

AND

WIRE HARNESS

PUMP 2

SEE DETAIL A OR B

TRANSDUCER PUMP TRANSDUCER PUMP

PWR (RED) SIG (WHITE) COM (BLACK) SHIELD/GRN

2 UP

MANIFOLD

MAC SERIES 46 (16P812 QTY

G3000

METER

PUMP 2

(EITHER, 239716,

258718,16M510,

OR 16M519)

GRND

SCREW

TWISTED PAIR CABLE (16W159)

DETAIL B, HIGH PRESSURE

PUMPS (24M707, 24M715)

2

1 2 3 4 5

BREAKOUT MODULE

(24N527)

3

1 2 3 4

WIRE HARNESS

(24P685) DRAIN/FOIL

MOTOR

MOUNTING

SCREW

1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9

PUMP ENCODER AND MOTOR

(16P037)

10

MOTOR

MOUNTING

SCREW

1 2

Figure 18 Electrical Schematic, Sheet 2, Part 1

CONTINUED ON THE NEXT PAGE

1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9

PUMP ENCODER AND MOTOR

(16P036)

10

332455E 35

Electrical Schematics

GUN TRIGGER INPUTS

GCA MODULE

(24N913)

1 2 3 4 5 6 7 8

3

9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25

EFCM

1 2 3 4 5 6 7 8

9

4

9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25

6

11

12

8

9

3

4

2

1

5

6

7

11

12

8

9

3

4

2

1

5

6

3

5

1

2

SIG

COM

SIG

COM

SIG

COM

COM

COM

GFB PRESSURE SWITCH (121323)

SOLVENT FLOW SWITCH (120278)

FLOW RATE ANALOG IN 1

FLOW RATE ANALOG COMMON 1

FLOW RATE ANALOG IN 2

FLOW RATE ANALOG COMMON 2

FLOW RATE ANALOG IN 3

FLOW RATE ANALOG COMMON 3

FLOW RATE ANALOG IN 4

FLOW RATE ANALOG COMMON 4

UNUSED

UNUSED

UNUSED

UNUSED

CABLE

(121003)

3

3

4

2

1

5

ADVANCED

DISPLAY MODULE

(24E451)

3

4

2

1

5

LIGHT

TOWER

(15X472)

4

25 PIN D-SUB CABLE

(16T659)

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25

1

BREAKOUT MODULE PUMP 3 (24N527)

2

1 2 3 4 5

3

1 2 3 4

4

1 2 3 4 5

5

1 2 3 4 5

6

1 2 3 4 1 2 3 4

7

5 6 7 8

8

1 2 3 4

ENCODER/MOTOR

AND

WIRE HARNESS

PUMP 3

SEE DETAIL A OR B

TRANSDUCER PUMP TRANSDUCER PUMP

PWR (RED) SIG (WHITE) COM (BLACK) SHIELD/GRN

3 UP

MANIFOLD

MAC SERIES 46 (16P812 QTY

G3000

METER

PUMP 3

(EITHER, 239716,

258718,16M510,

OR 16M519)

GRND

SCREW

TWISTED PAIR CABLE (16W159)

Figure 19 Electrical Schematic, Sheet 2, Part 2

CONTINUED ON THE NEXT PAGE

+48V COM +48V COM

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25

1

BREAKOUT MODULE PUMP 4 (24N527)

2

1 2 3 4 5

3

1 2 3 4

4

1 2 3 4 5

5

1 2 3 4 5

6

1 2 3 4 1 2 3 4

7

5 6 7 8

8

1 2 3 4

+48V COM +48V COM

ENCODER/MOTOR

AND

WIRE HARNESS

PUMP 4

SEE DETAIL A OR B

TRANSDUCER PUMP TRANSDUCER PUMP

PWR (RED) SIG (WHITE) COM (BLACK) SHIELD/GRN

4 UP

MANIFOLD

MAC SERIES 46 (16P812 QTY

G3000

METER

PUMP 4

(EITHER, 239716,

258718,16M510,

OR 16M519)

GRND

SCREW

TWISTED PAIR CABLE (16W159)

36 332455E

FROM CAN IS BOARD (24M485) ON PAGE 2

Electrical Schematics

FROM CAN IS BOARD (24M485) ON PAGE 2

2

CABLE (15V206)

FLUSH

COLOR 1

COLOR 2

COLOR 3

COLOR 4

COLOR 5

COLOR 6

COLOR 7

COLOR 8

MANIFOLD

+12VDC

COM

+12VDC

COM

+12VDC

COM

+12VDC

COM

+12VDC

COM

+12VDC

COM

+12VDC

COM

+12VDC

COM

+12VDC

COM

3

4

1

2

5

6

3

4

1

2

5

6

J15

J8

1 2 3 4 5

COLOR

CHANGE

MODULE 1

(COLORS

1 THRU 8)

J9

6

J16

3

4

1

2

5

6

3

4

1

2

5

6

3

4

1

2

5

6

J14 J10

1 2 3 4 5

3

4

1

2

5

6

+12VDC

COM

+12VDC

COM

+12VDC

COM

+12VDC

COM

+12VDC

COM

+12VDC

COM

+12VDC

COM

+12VDC

COM

+12VDC

COM

MANIFOLD

DUMP

COLOR 1

COLOR 2

COLOR 3

COLOR 4

COLOR 5

COLOR 6

COLOR 7

COLOR 8

*FLUSH

COLOR 9

COLOR 10

COLOR 11

COLOR 12

COLOR 13

COLOR 14

COLOR 15

COLOR 16

MANIFOLD

+12VDC

COM

+12VDC

COM

+12VDC

COM

+12VDC

COM

+12VDC

COM

+12VDC

COM

+12VDC

COM

+12VDC

COM

+12VDC

COM

3

4

1

2

5

6

J8

1 2 3 4 5

COLOR

CHANGE

MODULE 2

(COLORS

9 THRU 16)

J9

6

3

4

1

2

5

6

J15 J16

3

4

1

2

5

6

3

4

1

2

5

6

3

4

1

2

5

6

J14 J10

1 2 3 4 5

3

4

1

2

5

6

+12VDC

COM

+12VDC

COM

+12VDC

COM

+12VDC

COM

+12VDC

COM

+12VDC

COM

+12VDC

COM

+12VDC

COM

+12VDC

COM

MANIFOLD

DUMP*

COLOR 9

COLOR 10

COLOR 11

COLOR 12

COLOR 13

COLOR 14

COLOR 15

COLOR 16

*FLUSH

COLOR 17

COLOR 18

COLOR 19

COLOR 20

COLOR 21

COLOR 22

COLOR 23

COLOR 24

MANIFOLD

+12VDC

COM

+12VDC

COM

+12VDC

COM

+12VDC

COM

+12VDC

COM

+12VDC

COM

+12VDC

COM

+12VDC

COM

+12VDC

COM

3

4

1

2

5

6

3

4

1

2

5

6

1 2 3 4 5

COLOR

CHANGE

MODULE 3

(COLORS

17 THRU 24)

J8 J9

J15

6

J16

3

4

1

2

5

6

3

4

1

2

5

6

3

4

1

2

5

6

J14 J10

3

4

1

2

5

6

5 4 3 2 1

+12VDC

COM

+12VDC

COM

+12VDC

COM

+12VDC

COM

+12VDC

COM

+12VDC

COM

+12VDC

COM

+12VDC

COM

+12VDC

COM

MANIFOLD

DUMP*

COLOR 17

COLOR 18

COLOR 19

COLOR 20

COLOR 21

COLOR 22

COLOR 23

COLOR 24

FLUSH

CATALYST 1

CATALYST 2

CATALYST 3

CATALYST 4

MANIFOLD

+12VDC

COM

+12VDC

COM

+12VDC

COM

+12VDC

COM

+12VDC

COM

UNUSED

UNUSED

UNUSED

UNUSED

UNUSED

UNUSED

UNUSED

UNUSED

3

4

1

2

5

6

3

4

1

2

5

6

J8

CATALYST

CHANGE

MODULE 5

(CATALYST

1 THRU 4)

J9

6

3

4

1

2

5

6

J15 J16 3

4

1

2

5

6

3

4

1

2

5

6

J14 J10

3

4

1

2

5

6

1 2 3 4 5

+12VDC

COM

+12VDC

COM

+12VDC

COM

+12VDC

COM

+12VDC

COM

UNUSED

UNUSED

UNUSED

UNUSED

UNUSED

UNUSED

UNUSED

UNUSED

MANIFOLD

DUMP

CATALYST 1

CATALYST 2

CATALYST 3

CATALYST 4

*FLUSH

COLOR 25

COLOR 26

COLOR 27

COLOR 28

COLOR 29

COLOR 30

MANIFOLD

+12VDC

COM

+12VDC

COM

+12VDC

COM

+12VDC

COM

+12VDC

COM

+12VDC

COM

+12VDC

COM

UNUSED

UNUSED

UNUSED

UNUSED

3

4

1

2

5

6

1 2 3 4 5

COLOR

CHANGE

MODULE 4

(COLORS

25 THRU 32)

J8 J9

6

3

4

1

2

5

6

J15 J16

3

4

1

2

5

6

3

4

1

2

5

6

3

4

1

2

5

6

J14 J10

1 2 3 4 5

3

4

1

2

5

6

+12VDC

COM

+12VDC

COM

+12VDC

COM

+12VDC

COM

+12VDC

COM

+12VDC

COM

+12VDC

COM

UNUSED

UNUSED

UNUSED

UNUSED

MANIFOLD

DUMP*

COLOR 25

COLOR 26

COLOR 27

COLOR 28

COLOR 29

COLOR 30

2

CABLE (15V206)

Figure 20 Electrical Schematic, Sheet 3

* May be unused in some configurations.

CONTINUED ON THE NEXT PAGE

332455E 37

Electrical Schematics

FLUSH

CATALYST 3

CATALYST 4

MANIFOLD

COM

+12VDC

+12VDC

COM

UNUSED

UNUSED

UNUSED

UNUSED

UNUSED

UNUSED

UNUSED

UNUSED

UNUSED

3

4

1

2

J8

CATALYST

CHANGE

MODULE 6

(CATALYST

3 THRU 4)

J9

3

4

1

2

3

4

1

2

5

6

J15

6

J16 3

4

1

2

5

6

4

5

6

1

2

J14 J10

4

5

6

1

2

1 2 3 4 5

FLUSH

CATALYST 1

CATALYST 2

MANIFOLD

COM

+12VDC

+12VDC

COM

UNUSED

UNUSED

UNUSED

UNUSED

UNUSED

UNUSED

UNUSED

UNUSED

UNUSED

3

4

1

2

J8

5 4 3 2 1

CATALYST

CHANGE

MODULE 5

(CATALYST

1 THRU 2)

J9

3

4

1

2

3

4

1

2

J15

6

J16 3

4

1

2

4

5

6

1

2

J14 J10 4

5

6

1 2 3 4 5

1

2

+12VDC

COM

+12VDC

COM

MANIFOLD

DUMP

CATALYST 3

CATALYST 4

UNUSED

UNUSED

UNUSED

UNUSED

UNUSED

UNUSED

UNUSED

UNUSED

UNUSED

+12VDC

COM

+12VDC

COM

MANIFOLD

DUMP

CATALYST 1

CATALYST 2

UNUSED

UNUSED

UNUSED

UNUSED

UNUSED

UNUSED

UNUSED

UNUSED

Figure 21 Electrical Schematic, Sheet 3, Alternate

Configuration for Catalyst Change Control

CONTINUED ON THE NEXT PAGE

1 2 3 4 5

COLOR

CHANGE

MODULE 4

(COLORS

25 THRU 32)

38 332455E

Electrical Schematics

FROM CAN IS BOARD (24M485) ON PAGE 2

NON-HAZARDOUS LOCATION

HAZARDOUS LOCATION

COLOR FLUSH

COLOR 1

COLOR 2

COLOR 3

COLOR 4

COLOR 5

COLOR 6

COLOR 7

COLOR 8

MANIFOLD

+12VDC

COM

+12VDC

COM

COM

+12VDC

COM

+12VDC

COM

+12VDC

COM

+12VDC

COM

+12VDC

COM

3

4

1

2

5

6

3

4

1

2

J15

1 2 3 4 5

COLOR

CHANGE

MODULE 7

(COLORS

33 THRU 40)

J8 J9

7

J16

3

4

1

2

5

6

3

4

1

2

3

4

1

2

5

6

J14 J10

1 2 3 4 5

3

4

1

2

5

6

+12VDC

COM

+12VDC

COM

+12VDC

COM

+12VDC

COM

+12VDC

COM

+12VDC

COM

+12VDC

COM

+12VDC

COM

+12VDC

COM

MANIFOLD

CATALYST FLUSH

CATALYST 1

CATALYST 2

CATALYST 3

CATALYST 4

COLOR 9

COLOR 10

COLOR 11

COLOR 12

COLOR 13

COLOR 14

COLOR 15

COLOR 16

COLOR 17

COLOR 18

COLOR 19

COLOR 20

COLOR 21

MANIFOLD

+12VDC

COM

+12VDC

COM

+12VDC

COM

+12VDC

COM

+12VDC

COM

+12VDC

COM

+12VDC

COM

+12VDC

COM

+12VDC

COM

4

5

6

1

2

3

4

1

2

5

6

1 2 3 4 5

COLOR

CHANGE

MODULE 8

(COLORS

41 THRU 48)

J8 J9

J15

7

J16

4

5

6

1

2

3

4

1

2

5

6

3

4

1

2

J14 J10

3

4

1

2

5 4 3 2 1

+12VDC

COM

+12VDC

COM

+12VDC

COM

+12VDC

COM

+12VDC

COM

+12VDC

COM

+12VDC

COM

MANIFOLD

COLOR 22

COLOR 23

COLOR 24

COLOR 25

COLOR 26

COLOR 27

COLOR 28

COLOR 29

COLOR 30

5 4 3 2 1

BOOTH CONTROL

(24M731)

Figure 22 Electrical Schematic, Sheet 3, Hazardous

Location

332455E 39

Electrical Schematics

Optional Cables and Modules

NOTE: The total length of all cable used in the system must not exceed 150 ft (45 m). See the

Electrical Schematics, page 34

.

M12 CAN Cables, for Hazardous Locations

NOTE: The total length of cable used in the hazardous location must not exceed 120 ft (36 m).

Cable Part No.

16V423

Length ft (m)

2.0 (0.6)

16V424

16V425

16V426

16V427

3.0 (1.0)

6.0 (2.0)

10.0 (3.0)

15.0 (5.0)

16V428

16V429

16V430

25.0 (8.0)

50.0 (16.0)

100.0 (32.0)

15U531

15U532

15V205

15V206

M12 CAN Cables, for Non-Hazardous

Locations Only

2.0 (0.6)

3.0 (1.0)

6.0 (2.0)

10.0 (3.0)

15V207

15V208

15U533

15V213

15.0 (5.0)

25.0 (8.0)

50.0 (16.0)

100.0 (32.0)

CAN Cables, for Non-Hazardous

Locations Only

Cable Part No.

125306

Length ft (m)

1.0 (0.3)

123422

121000

121227

121001

121002

121003

120952

121201

121004

121228

1.3 (0.4)

1.6 (0.5)

2.0 (0.6)

3.0 (1.0)

5.0 (1.5)

10.0 (3.0)

13.0 (4.0)

20.0 (6.0)

25.0 (8.0)

50.0 (15.0)

16T659

16V659

25 Pin D-SUB Cables, for Non-Hazardous

Locations Only

2.5 (0.8)

6.0 (1.8)

Alternates for Communication Module

24R910, for Non-Hazardous Locations Only

Module Part No.

15V759

15V760

Module Part No.

15V761

15V762

Alternates for Color Change Modules by Part Number (Factory Configuration), for

Non-Hazardous Locations Only

Module Part No.

24T557

Description

2 color/2 catalyst

24T558

24T559

24T560

4 color/4 catalyst

6 color/6 catalyst

8 color/8 catalyst

Alternates for Color Change Modules by Part Number (Factory Configuration), for

Hazardous Locations Only

24T571

24T572

2 color/2 catalyst

4 color/2 catalyst

24T573

24T574

6 color/2 catalyst

8 color/2 catalyst

40 332455E

Repair

Repair

• To avoid electric shock, turn off power at the main circuit breaker before opening the control module.

• All electrical wiring must be done by a qualified electrician and comply with all local codes and regulations.

• Do not substitute or modify system components as this may impair intrinsic safety.

NOTICE

To avoid damaging the circuit boards, wear Part

No. 112190 grounding strap on your wrist and ground appropriately.

To avoid electrical component damage, remove all system power before plugging any connectors.

Replace a Color Valve

Figure 23 Remove Retainer

3. Using the other end of the tool (114), screw it all the way onto the valve (3). Pull the valve from the manifold.

1. Flush and relieve pressure as described in your

PD2K operation manual.

2. Engage the pins of the tool (114) with the notches in the retainer (5) and unscrew the retainer.

Figure 24 Remove the Valve

NOTE: See manual 332454 to repair the valve.

4. Install the valve in the reverse order of disassembly. Be sure all o-rings are in place and lubricated, and that the valve is seated completely in the manifold.

5. Return the system to service.

332455E 41

Repair

Replace a Solenoid Replace the Color Change Board

Fuse

1. Remove electrical power from the system.

2. Remove air supply pressure from the system.

3. Remove the color change module cover (304).

4. Disconnect the two solenoid wires from the color change board (302). See the color change board wiring diagrams in the

Electrical Schematics, page 34

.

5. Remove the solenoid (310) from the manifold

(309).

6. Install the new solenoid.

7. Connect the two solenoid wires to the color change board (302). See the color change board wiring diagrams in the

Electrical Schematics, page 34

.

8. Reinstall the cover.

NOTE: Replacing the fuse with a non-Graco fuse voids the IS system safety approval.

Description Fuse Part

No.

F1 12369

0

Fuse; 125 mA, intrinsically safe

1. Remove electrical power from the system.

2. Remove the color change module cover (304).

3. Locate fuse F1 (302a) on the color change board.

Pull the fuse away from the board.

4. Install the new fuse.

5. Reinstall the cover. Restore electrical power to the system.

42 332455E

Repair

Replace the Color Change Board

NOTICE

To avoid damaging the circuit boards, wear Part

No. 112190 grounding strap on your wrist and ground appropriately.

To avoid electrical component damage, remove all system power before plugging any connectors.

1. Remove electrical power from the system.

2. Remove the color change module cover (304).

3. Note where each cable is connected, then disconnect all cables from the color change board connectors.

4. Remove the seven mounting screws (303) and the board (302).

5. Install the new board. Reinstall the screws.

6. Reconnect the cables to the proper connectors, as noted in step 3. See

Electrical Schematics, page 34 .

7. Reinstall the cover (304). Restore electrical power to the system.

Figure 25 Control Module Repair (Non-IS Module

Shown)

332455E 43

Parts

Parts

Non-IS System Shown

Detail of Back Pressure Regulator (High Pressure Outlet Stack only)

44 332455E

Parts

Non-IS Color Change Kits

Ref.

No.

101

102

103

104

105

106

107

108

109

110

111

114

Part

No.

Description

24U237 BRACKET, mounting

◆ KIT, manifold, valve

100157 SCREW, cap, hex head;

1/4–20 x 0.375 in. (10 mm)

103195 SCREW, cap, hex head;

1/4–20 x 4.0 in. (101 mm)

100016 WASHER, lock; 1/4

100015 NUT, hex; 1/4–20

24N346 HOSE, fluid; 1/4 npsm (fbe);

2.5 ft (0.76 m); ptfe

◆ KIT, module, control

15V206 CABLE, CAN; 5–pin female;

10 ft (3.05 m)

16V819 GROMMET, cable

24U236 TOOL, repair, valve (not shown)

◆ TOOL, installation, valve (not shown)

Qty

1

2

4

4

1

1

1

1

4

4

2

1

Ref.

No.

115

120

121

122

123

Part

No.

Description

598095 TUBE; nylon; 5/32 in. (4 mm)

OD

222200 REGULATOR, back pressure; used on high pressure kits only (see detail drawing); see manual 307892

113070 NIPPLE; 3/8 npt x 1/4 npt; sst; used on high pressure kits only (see detail drawing)

110290 TEE; 1/4 npt(f); sst; used on high pressure kits only (see detail drawing)

112564 GAUGE, pressure, fluid; used on high pressure kits only (see detail drawing)

Qty

1

2

1

1

◆ See the following tables for the part number used in your color change kit.

Low Pressure Non-IS Kits

Kit No.

24R915

24R916

24R917

24R918

24R919

24R920

24R921

24R922

Kit Description Standard Valve

Manifold Kits

(102) [see

Low Pressure

Valve Manifold

Kits, page 49

for all available kits]

Control Module

Kit (108) [see

Non-IS Color

Change Control

Modules, page

60

for parts]

Tool (114)

2 color or 2 catalyst

4 color or 4 catalyst

Low Pressure Non-Circulating Color Change Kits

24T458 24T557 24U239

24T460 24T558 24U239

6 color

8 color

24T462

24T464

24T559

24T560

24U239

24U239

Low Pressure Circulating Color Change Kits

24T488 24T557 24U239 2 color

4 color

6 color

8 color

24T490

24T492

24T494

24T558

24T559

24T560

24U239

24U239

24U239

Tube Length

(115)

60 ft (18.3 m)

120 ft (36.6 m)

210 ft (64.05 m)

360 ft (109.8 m)

60 ft (18.3 m)

120 ft (36.6 m)

210 ft (64.05 m)

360 ft (109.8 m)

332455E 45

Parts

High Pressure Non-IS Kits

Kit No.

24R959

24R960

24R961

24R962

24T579

24T580

24R963

24R964

24R965

24R966

Kit Description Standard Valve

Manifold Kits

(102) [see

High Pressure

Valve Manifold

Kits, page 55

for all available kits]

Control Module

Kit (108) [see

Non-IS Color

Change Control

Modules, page

60

for parts]

Tool (114)

2 color or 2 catalyst

High Pressure Non-Circulating Color Change Kits

24T648 24T557 24U240

4 color or 4 catalyst

24T650 24T558 24U240

6 color

8 color

24T652

24T654

24T559

24T560

24U240

24U240

High Pressure Acid Compatible Non-Circulating Catalyst Change Kits

2 catalyst 24U182 24T557 24U240

4 catalyst

2 color

4 color

6 color

8 color

24U183 24T558 24U240

High Pressure Circulating Color Change Kits

24T678 24T557 24U240

24T680

24T682

24T684

24T558

24T559

24T560

24U240

24U240

24U240

Tube Length

(115)

60 ft (18.3 m)

120 ft (36.6 m)

210 ft (64.05 m)

360 ft (109.8 m)

60 ft (18.3 m)

120 ft (36.6 m)

60 ft (18.3 m)

120 ft (36.6 m)

210 ft (64.05 m)

360 ft (109.8 m)

46 332455E

Parts

IS Color Change Kits

Ref.

No.

101

102

103

104

105

106

107

Part

No.

Description

24U237 BRACKET, mounting

◆ KIT, manifold, valve; must be ordered separately. See

Valve Manifolds, page 49

for available kits.

100157 SCREW, cap, hex head;

1/4–20 x 0.375 in. (10 mm)

103195 SCREW, cap, hex head;

1/4–20 x 4.0 in. (101 mm)

100016 WASHER, lock; 1/4

100015 NUT, hex; 1/4–20

24N346 HOSE, fluid; 1/4 npsm (fbe);

2.5 ft (0.76 m); ptfe

Qty

1

2

4

4

4

4

2

110

111

114

115

Ref.

No.

108

109

Part

No.

Description

KIT, module, control

16V426 CABLE, CAN, intrinsically safe; 5–pin female; 10 ft (3.05

m)

16V819 GROMMET, cable

24U236 TOOL, repair, valve

◆ TOOL, installation, valve

598095 TUBE; nylon; 5/32 in. (4 mm)

OD

Qty

1

1

1

1

1

◆ See the following tables for the part number used in your color change kit.

Low Pressure IS Kits

Kit No.

24T343

24T344

24T345

24T346

24T347

24T348

24T349

24T350

Kit Description Standard Valve

Manifold Kits

(102) [see

Low Pressure

Valve Manifold

Kits, page 49

for all available kits]

2 color or 2 catalyst

Low Pressure Non-Circulating Color Change Kits

24T458 (2) 24T571 24U239

4 color or 4 catalyst

6 color

24T458,

24T460

24T458,

24T462

Control Module Kit (108)

[see

62

IS Color

Change Control

Modules, page

for parts]

24T572

24T573

Tool (114)

24U239

24U239

8 color

2 color

4 color

6 color

8 color

24T458,

24T464

24T574 24U239

Low Pressure Circulating Color Change Kits

24T458,

24T488

24T458,

24T490

24T571

24T572

24U239

24U239

24T573 24U239 24T458,

24T492

24T458,

24T494

24T574 24U239

Tube Length

(115)

60 ft (18.3 m)

120 ft (36.6 m)

210 ft (64.05 m)

360 ft (109.8 m)

60 ft (18.3 m)

120 ft (36.6 m)

210 ft (64.05 m)

360 ft (109.8 m)

332455E 47

Parts

High Pressure IS Kits

Kit No.

24T351

24T353

24T353

24T354

24T355

24T356

24T357

24T358

Kit Description Standard Valve

Manifold Kits

(102) [see

High Pressure

Valve Manifold

Kits, page 55

for all available kits]

4 color or 4 catalyst

6 color

8 color

24T648,

24T650

24T648,

24T652

24T648,

24T654

Control Module Kit (108)

[see

IS Color

Change Control

Modules, page

62

for parts]

Tool (114)

2 color or 2 catalyst

High Pressure Non-Circulating Color Change Kits

24T648 (2) 24T571 24U240

24T572

24T573

24T574

24U240

24U240

24U240

2 color

4 color

6 color

8 color

High Pressure Circulating Color Change Kits

24T648,

24T678

24T571 24U240

24T572 24U240 24T648,

24T680

24T648,

24T682

24T573 24U240

24T648,

24T684

24T574 24U240

Tube Length

(115)

60 ft (18.3 m)

120 ft (36.6 m)

210 ft (64.05 m)

360 ft (109.8 m)

60 ft (18.3 m)

120 ft (36.6 m)

210 ft (64.05 m)

360 ft (109.8 m)

48 332455E

Parts

Valve Manifolds

Low Pressure Valve Manifold Kits

Non-Circulating Valve Manifold Kits

24T467

24T468

24T469

24T470

24T471

24T472

24T473

24T474

24T475

24T476

Kit No.

24T457

24T458

24T459

24T460

24T461

24T462

24T463

24T464

24T465

24T466

24T477

24T478

24T479

24T480

24T481

24T482

24T483

24T484

24T485

24T486

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

Series

A

A

A

A

A

A

A

A

A

A

A

22 valves

23 valves

24 valves

25 valves

26 valves

27 valves

28 valves

29 valves

30 valves

31 valves

12 valves

13 valves

14 valves

15 valves

16 valves

17 valves

18 valves

19 valves

20 valves

21 valves

Kit Description

2 valves

3 valves

4 valves

5 valves

6 valves

7 valves

8 valves

9 valves

10 valves

11 valves

Circulating Valve Manifold Kits

24T497

24T498

24T499

24T500

24T501

24T502

24T503

24T504

24T505

24T506

Kit No.

24T487

24T488

24T489

24T490

24T491

24T492

24T493

24T494

24T495

24T496

24T507

24T508

24T509

24T510

24T511

24T512

24T513

24T514

24T515

24T516

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

Series

A

A

A

A

A

A

A

A

A

A

A

22 valves

23 valves

24 valves

25 valves

26 valves

27 valves

28 valves

29 valves

30 valves

31 valves

12 valves

13 valves

14 valves

15 valves

16 valves

17 valves

18 valves

19 valves

20 valves

21 valves

Kit Description

2 valves

3 valves

4 valves

5 valves

6 valves

7 valves

8 valves

9 valves

10 valves

11 valves

332455E 49

Parts

Valve Manifold Kit Parts

50 332455E

Parts

1

2

3

Ref.

No.

6

7

4

5

8

9

10

Part

No.

Description

16P259 MANIFOLD

111450 O-RING; chemically resistant

24T441 VALVE, for non-circulating kits; includes item 2

24T442 VALVE, for circulating kits; includes item 2

24R051 PLUG, cc valve

16N256 RETAINER, nut

111457 O-RING; ptfe

24T521 PLATE, outlet, manifold

24T522 PLATE, end, manifold

157974 WASHER, plain

104092 SCREW, cap, socket head;

10–24 x 0.625 in. (16 mm)

100179 NUT, hex; 10–24

Qty

14

15

16

17

18

19

Ref.

No.

12

13

Part

No.

Description

104893 O-RING; ptfe

24T523 FITTING, fluid; 7/16–20 x 1/4 npt(m)

111328 CONNECTOR, tube;

10–32(m) x 5/32 in. (4 mm) OD tube

24T525 ROD, connecting; 3 in. (76 mm)

24T524 ROD, connecting; 1.5 in. (38 mm)

111504 O-RING; chemically resistant

557716 PLUG; 7/16–20

104644 PLUG, screw; 10–32 x 0.156

in. (4 mm)

Qty

11

★ See the following tables to determine the quantity of each part in your valve manifold kit.

Low Pressure Non-Circulating Valve Manifold Kit Part Quantities

Kit No.

1

24T457 1

24T458 2

24T459 2

24T460 3

24T461 3

24T462 4

2

2

4

4

6

6

8

3

2

3

8 8

10 9

4

5

6

7

4

0

1

24T463 4

24T464 5

24T465 5

24T466 6

24T467 6

24T468 7

24T469

24T470

24T471

24T472

7

8

8

9

14 14 0

16 15 1

16 16 0

18 17 1

24T473 9 18 18 0

24T474 10 20 19 1

24T475 10 20 20 0

0

1

0

1

0

1

10 10 0

12 11 1

12 12 0

14 13 1

5

2

6

2

4 3 1

4

6

6

8

8 5

10 6

10 6

12 7

12 7

14 8

3

4

4

5

14 8

16 9

16 9 1

18 10 1

1

1

18 10 1

20 11 1

20 11 1

1

1

1

1

1

1

1

1

1

1

7

1

3

3

3

3

3

3

3

3

3

3

3

3

3

3

3

3

3

3

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

Reference Numbers

8 10 12 13 14 15

1 3 3 3 2 0

4 4 3 3 0

5

6

7

8

5

6

7

8

4

5

6

7

3

9 9 8

10 10 9

11 11 10 6

12 12 11 9

13 13 12 9

14 14 13 9

6

6

3

3

6

15 15 14 9 3

16 16 15 12 0

17 17 16 12 0

18 18 17 12 3

19 19 18 12 3

20 20 19 15 0

21 21 20 15 0

3

0

0

3

0

3

0

3

3

0

16 17 18

3 1 2

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

5 2

14 0

17 2

16 0

19 2

18 0

21 2

20 0

4

7

6

9

8 0

11 2

10 0

13 2

12 0

15 2

0

2

0

2

19

0

332455E 51

Parts

Kit No.

1 2 3 4

24T476 11 22 21 1

24T477 11 22 22 0

24T478 12 24 23 1

24T479 12 24 24 0

24T480 13 26 25 1

24T481 13 26 26 0

24T482 14 28 27 1

24T483 14 28 28 0

24T484 15 30 29 1

24T485 15 30 30 0

24T486 16 32 31 1

5 6 7

22 12 1

22 12 1

24 13 1

24 13 1

26 14 1

26 14 1

28 15 1

28 15 1

30 16 1

30 16 1

32 17 1

Reference Numbers

1

1

1

1

1

1

1

1

8

1

1

1

3

3

3

3

3

3

3

3

3

3

10 12

3 22

13 14 15

22 21 15

16 17 18

3 1 23

19

2

23 23 22 15 3

24 24 23 18 0

1

1

22 0

25 2

25

26

27

28

29

30

31

32

25

26

27

28

29

30

31

32

24

25

26

27

28

29

30

31

18

18

18

21

21

21

21

24

0

3

3

0

0

3

3

0

1

1

1

1

1

1

1

1

24

27

26

29

28

31

30

33

0

2

0

2

0

2

0

2

52 332455E

Parts

Low Pressure Circulating Valve Manifold Kit Part Quantities

Kit No.

1

24T487 1

24T488 2

24T489 2

24T490 3

24T491 3

24T492 4

24T493

24T494

4

5

2

2

4

4

6

6

8

3

2

3

8 8

10 9

4

5

6

7

4

0

1

24T495 5

24T496 6

24T497 6

24T498 7

24T499 7

24T500 8

24T501 8

24T502 9

16 15 1

16 16 0

18 17 1

24T503 9 18 18 0

24T504 10 20 19 1

0

1

0

1

0

1

10 10 0

12 11 1

12 12 0

14 13 1

14 14 0

24T505 10 20 20 0

24T506 11 22 21 1

24T507 11 22 22 0

24T508 12 24 23 1

24T509 12 24 24 0

24T510 13 26 25 1

24T511 13 26 26 0

24T512 14 28 27 1

24T513 14 28 28 0

24T514 15 30 29 1

24T515 15 30 30 0

24T516 16 32 31 1

5

2

6

2

4 3 1

20 11 1

22 12 1

22 12 1

24 13 1

24 13 1

26 14 1

26 14 1

28 15 1

28 15 1

30 16 1

30 16 1

32 17 1

4

6

6

8

3

4

4

5

8

10

5

6

10 6

12 7

12 7

14 8

14 8

16 9 1

16 9 1

18 10 1

18 10 1

20 11 1

1

1

1

1

1

1

1

1

1

1

1

7

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

Reference Numbers

8 10 12 13 14 15

1 3 5 5 2 0

3

3

3

3

3

3

3

3

3

3

3

3

3

3

3

3

3

3

3

3

3

3

3

3

3

3

3

3

3

7 7 3 3 0

9

11

13

15

9

11

13

15

4

5

6

7

3

17 17 8

19 19 9

21 21 10 6

23 23 11 9

25 25 12 9

27 27 13 9

29 29 14 9

3

3

6

6

6

31 31 15 12 0

33 33 16 12 0

35 35 17 12 3

37 37 18 12 3

39 39 19 15 0

3

0

0

0

3

3

3

0

3

3

0

41 41 20 15 0

43 43 21 15 3

45 45 22 15 3

47 47 23 18 0

49 49 24 18 0

51 51 25 18 3

53 53 26 18 3

55 55 27 21 0

57 57 28 21 0

59 59 29 21 3

61 61 30 21 3

63 63 31 24 0

16 17 18

3 1 0

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

2

0

2

0

2

0

2

0

2

0

2

0

2

0

2

2

0

2

0

2

0

0

2

2

0

0

2

0

2

2

0

2

0

2

0

2

0

2

0

2

0

2

0

2

2

0

2

0

2

0

0

2

2

0

0

2

0

2

19

0

332455E 53

Parts

Notes

54 332455E

Parts

High Pressure Valve Manifold Kits

Non-Circulating Valve Manifold Kits

24T656

24T657

24T658

24T659

24T660

24T661

24T662

24T663

24T664

24T665

Kit No.

24T647

24T648

24T649

24T650

24T651

24T652

24T653

24T654

24T655

24T666

24T667

24T668

24T669

24T670

24T671

24T672

24T673

24T674

24T675

24T676

24T845 (acidcatalyzed)

24T846 (acidcatalyzed)

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

Series

A

A

A

A

A

A

A

A

A

A

A

A

A

A

21 valves

22 valves

23 valves

24 valves

25 valves

26 valves

27 valves

28 valves

29 valves

30 valves

31 valves

3 valves

11 valves

12 valves

13 valves

14 valves

15 valves

16 valves

17 valves

18 valves

19 valves

20 valves

Kit Description

2 valves

3 valves

4 valves

5 valves

6 valves

7 valves

8 valves

9 valves

10 valves

5 valves

Circulating Valve Manifold Kits

24T686

24T687

24T688

24T689

24T690

24T691

24T692

24T693

24T694

24T695

Kit No.

24T677

24T678

24T679

24T680

24T681

24T682

24T683

24T684

24T685

24T696

24T697

24T698

24T699

24T700

24T701

24T702

24T703

24T704

24T705

24T706

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

Series

A

A

A

A

A

A

A

A

A

A

A

A

A

21 valves

22 valves

23 valves

24 valves

25 valves

26 valves

27 valves

28 valves

29 valves

30 valves

31 valves

11 valves

12 valves

13 valves

14 valves

15 valves

16 valves

17 valves

18 valves

19 valves

20 valves

Kit Description

2 valves

3 valves

4 valves

5 valves

6 valves

7 valves

8 valves

9 valves

10 valves

332455E 55

Parts

Valve Manifold Kit Parts

56 332455E

Parts

6

7

4

5

8

10

1

2

Ref.

No.

3

12

Part

No.

Description

16N271 MANIFOLD, for circulating kits

111450 O-RING; chemically resistant

24T58

1

VALVE, for non-circulating kits; includes item 2

24T582 VALVE, for circulating kits; includes item 2

24T583 VALVE, for non-circulating, acid compatible kits; includes item 2

24R052 PLUG, cc valve

16N269 RETAINER, nut

111457 O-RING; ptfe

24T725 PLATE, outlet, manifold

24T726 PLATE, end, manifold

111820 SCREW, cap, socket head;

10–24 x 0.75 in. (19 mm)

104893 O-RING; ptfe

Qty Ref.

No.

13

14

15

16

18

19

Part

No.

Description

24T523 FITTING, fluid; 7/16–20 x 1/4 npt(m)

111328 CONNECTOR, tube;

10–32(m) x 5/32 in. (4 mm) OD tube

24T729 ROD, connecting; 3.290 in.

(84 mm)

24T728 ROD, connecting; 1.645 in.

(42 mm)

557716 PLUG; 7/16–20

104644 PLUG, screw; 10–32 x 0.156

in. (4 mm)

Qty

★ See the following tables to determine the quantity of each part in your valve manifold kit.

High Pressure Non-Circulating Valve Manifold Kit Part Quantities

Kit No.

1

24T647 1

24T648 2

24T649 2

24T650

24T653

24T654

3

24T651 3

24T652 4

4

5

2

2

4

4

6

6

8

3

2

3

8 8

10 9

4

5

6

7

4

0

1

24T655 5

24T656 6

24T657 6

24T658 7

24T659 7

24T660 8

24T661 8

24T662 9

16 15 1

16 16 0

18 17 1

24T663 9 18 18 0

24T664 10 20 19 1

0

1

0

1

0

1

10 10 0

12 11 1

12 12 0

14 13 1

14 14 0

5

2

4

6

2

3

4

6

6

8

8 5

10 6

10 6

12 7

12 7

3

4

4

5

14 8

14 8

16 9

16 9

18 10

18 10

20 11

7

Reference Numbers

8 10 12

1 1 3 3

1 1 3

3

3

3

3

3

3

3

3

3

3

3

3

3

3

3

3

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

13

3

14

2

4 4 3 1

5 5

6

7

6

7

8

9

8

9 8

10 10 9

6

7

4

5

1

11 11 10 2

12 12 11 3

13 13 12 3

14 14 13 3

15 15 14 3

1

1

2

2

2

16 16 15 4

17 17 16 4

18 18 17 4

19 19 18 4

20 20 19 5

15

0

0

1

0

0

0

1

1

1

0

1

1

0

0

0

1

1

0

16

1

1

0

1

0

0

1

1

0

0

1

0

1

1

0

1

0

1

18

0

2

0

2

0

0

2

2

0

0

2

0

2

2

0

2

0

2

19

0

332455E 57

Parts

Kit No.

1 2 3 4

24T665 10 20 20 0

24T666 11 22 21 1

24T667 11 22 22 0

24T668 12 24 23 1

24T669 12 24 24 0

24T670 13 26 25 1

24T671 13 26 26 0

24T672 14 28 27 1

24T673 14 28 28 0

24T674 15 30 29 1

24T675 15 30 30 0

24T676 16 32 31 1

24T845 2 4 3 1

24T846 3 6 5 1

5 6

20 11

22 12

22 12

24 13

24 13

26 14

26 14

28 15

28 15

30 16

30 16

32 17

4 3

6 4

7

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

8

1

1

1

1

1

1

1

1

3

3

3

3

3

3

3

3

10

3

3

3

3

3

3

Reference Numbers

12 13 14 15

21 21 20 5

22 22 21 5

23 23 22 5

24 24 23 6

25 25 24 6

26 26 25 6

27 27 26 6

28 28 27 7

29 29 28 7

30 30 29 7

31 31 30 7

32 32 31 8

4 4 3 1

6 6 5 1

1

0

1

0

1

0

1

0

18

0

1

1

1

1

0

1

1

0

0

0

0

1

1

16

0

0

0

1

1

1

2

0

2

0

2

0

2

0

19

0

2

2

2

2

0

58 332455E

Parts

High Pressure Circulating Valve Manifold Kit Part Quantities

Kit No.

1

24T677 1

24T678 2

24T679 2

24T680

24T683

24T684

3

24T681 3

24T682 4

4

5

2

2

4

4

6

6

8

3

2

3

8 8

10 9

4

5

6

7

4

0

1

24T685 5

24T686 6

24T687 6

24T688 7

24T689 7

24T690 8

24T691 8

24T692 9

16 15 1

16 16 0

18 17 1

24T693 9 18 18 0

24T694 10 20 19 1

0

1

0

1

0

1

10 10 0

12 11 1

12 12 0

14 13 1

14 14 0

24T695 10 20 20 0

24T696 11 22 21 1

24T697 11 22 22 0

24T698 12 24 23 1

24T699 12 24 24 0

24T700 13 26 25 1

24T701 13 26 26 0

24T702 14 28 27 1

24T703 14 28 28 0

24T704 15 30 29 1

24T705 15 30 30 0

24T706 16 32 31 1

5

2

6

2

4 3

14 8

14 8

16 9

16 9

18 10

18 10

20 11

20 11

22 12

22 12

24 13

24 13

4

6

6

8

8 5

10 6

10 6

12 7

12 7

3

4

4

5

26 14

26 14

28 15

28 15

30 16

30 16

32 17

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

7

Reference Numbers

8 10 12

1 1 3 5

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

3

3

3

3

3

3

3

3

3

3

3

3

3

3

3

3

3

3

3

3

3

3

3

3

3

3

3

3

3

13

5

14

2

7 7 3 1

9

11

13

15

9

11

13

15

4

5

6

7

1

17 17 8

19 19 9

21 21 10 2

23 23 11 3

25 25 12 3

27 27 13 3

29 29 14 3

1

1

2

2

2

31 31 15 4

33 33 16 4

35 35 17 4

37 37 18 4

39 39 19 5

41 41 20 5

43 43 21 5

45 45 22 5

47 47 23 6

49 49 24 6

51 51 25 6

53 53 26 6

55 55 27 7

57 57 28 7

59 59 29 7

61 61 30 7

63 63 31 8

15

0

2

0

2

0

2

0

2

0

2

0

2

0

2

0

2

2

0

2

0

2

0

0

2

2

0

0

2

0

2

18

0

0

0

1

1

0

0

0

0

1

1

0

1

0

0

1

1

1

0

1

0

0

0

1

1

1

0

1

1

0

16

1

2

0

2

0

2

0

2

0

2

0

2

0

2

0

2

2

0

2

0

2

0

0

2

2

0

0

2

0

2

19

0

332455E 59

Parts

Color Change Control Module Kits

Non-IS Color Change Control Modules

60 332455E

Parts

307

308

309

310

311

Ref.

No.

301

302

Part

No.

Description

16P855 PANEL

24T566 BOARD, circuit

302a 123690 FUSE; 125 mA

303 112324 SCREW, machine, pan head;

4–40 x 0.25 in. (6 mm)

304

305

24T562 COVER

119162 CONNECTOR, 6–position

312

313

314

315

116343 SCREW, ground; M5 x 0.8

123691 HOLDER, fuse

24T563 MANIFOLD

16P316 SOLENOID

117831 SCREW, machine, pan head;

6–32 x 0.5 in. (13 mm)

103833 SCREW, machine, pan head;

10–32 x 0.375 in. (10 mm)

24T565 PLUG; 5/8–32; includes item

314

113418 O-RING; buna-N

100139 PLUG, pipe; 1/8 npt

Qty

1

1

1

2

4

1

6

1

1

8

14

3

Ref.

No.

316

317

318

319

320

321

322

324

332

Part

No.

Description

C06061 MUFFLER

115671 FITTING, connector; 1/8 npt(m) x 1/4 in. (6 mm) OD tube

112698 ELBOW; 1/8 npt(m) x 1/4 in.

(6 mm) OD tube

590332 TUBE; polyethylene; 1/4 in. (6 mm) OD

598095 TUBE; nylon; 5/32 in. (4 mm)

OD

— — — STRAP, tie

— — — FERRULE

114263 FITTING, connector; 1/8 npt(m) x 5/32 in. (4 mm) OD tube

151395 WASHER

Qty

2

1

2

1

1

4

★ See the following table to determine the quantity of each part in your control module kit.

Parts labeled — — — are not available separately.

Non-IS Control Module Part Quantities

Find your module kit no. in the left column and the desired reference number in the top row to find the part quantity used in your control module kit.

Kit No.

24T557

24T558

24T559

24T560

Kit

Description

2 color

4 color

6 color

8 color

6

6

2

4

6–Position

Connector

(305)

Solenoid

(310)

6

10

14

18

Plug (313) Tie Strap

(321)

12

8

4

0

4

4

4

4

Ferrule

(322)

12

20

28

36

Connector

Fitting

(324)

6

10

14

18

332455E 61

Parts

IS Color Change Control Modules

62 332455E

Parts

307

308

309

310

311

Ref.

No.

301

302

Part

No.

Description

16U742 PANEL

24T566 BOARD, circuit

302a 123690 FUSE; 125 mA

303 112324 SCREW, machine, pan head;

4–40 x 0.25 in. (6 mm)

304

305

24U567 COVER

119162 CONNECTOR, 6–position

116343 SCREW, ground; M5 x 0.8

123691 HOLDER, fuse

312

15T636 MANIFOLD

121324 SOLENOID

16M00

7

SCREW, machine, serrated head; 10–32 x 0.5 in. (13 mm)

103833 SCREW, machine, pan head;

10–32 x 0.375 in. (10 mm)

313

314

315

316

121628 SCREW, self-sealing; 4–40 x

0.25 in. (6 mm)

113418 O-RING; buna-N

100139 PLUG, pipe; 1/8 npt

C06061 MUFFLER

Qty

1

1

1

2

4

1

6

1

1

4

Ref.

No.

317

318

319

320

321

322

324

331

332

333

334

335

Part

No.

Description

115671 FITTING, connector; 1/8 npt(m) x 1/4 in. (6 mm) OD tube

112698 ELBOW; 1/8 npt(m) x 1/4 in.

(6 mm) OD tube

590332 TUBE; polyethylene; 1/4 in. (6 mm) OD

598095 TUBE; nylon; 5/32 in. (4 mm)

OD

— — — STRAP, tie

— — — FERRULE

109193 ELBOW, connector; 10–32

(m) x 5/32 in. (4 mm) OD tube

16U743 SPACER

16U744 PLATE, non-conductive

16U745 PLATE, ground

16U746 SCREW, pan-head; 4–40

C19289 NUT; 4–40

Qty

1

2

1

1

6

1

1

3

3

14

3

2

★ See the following table to determine the quantity of each part in your control module kit.

Parts labeled — — — are not available separately.

IS Control Module Part Quantities

Find your module kit no. in the left column and the desired reference number in the top row to find the part quantity used in your control module kit.

Kit No.

24T571

Kit

Description

6–Position

Connector

(305)

2

Solenoid

(310)

6

Plug (313)

12

Tie Strap

(321)

4

Ferrule

(322)

12

Connector

Fitting

(324)

6

24T572

24T573

24T574

2 color and

2 catalyst

4 color and

2 catalyst

6 color and

2 catalyst

8 color and

2 catalyst

4

6

6

10

14

18

8

4

0

4

4

4

20

28

36

10

14

18

332455E 63

Parts

Expansion Kits

Non-IS Expansion Kits

The following kits are available to add color valves in a non-IS area. See

Install an Expansion Kit, page 28

for instructions.

Low Pressure Expansion Kits High Pressure Expansion Kits

Kit No.

24T443

24T444

24T445

24T446

24T447

24T448

Kit Description

One non-circulating valve

(replaces a plug). Includes valve, solenoid, fittings, and tubing.

One circulating valve (replaces a plug). Includes valve, solenoid, fittings, and tubing.

Manifold with one non-circulating valve. Includes valve, plug, solenoid, fittings, and tubing.

Manifold with one circulating valve.

Includes valve, plug, solenoid, fittings, and tubing.

Manifold with two non-circulating valves. Includes valves, solenoids, fittings, and tubing.

Manifold with two circulating valves. Includes valves, solenoids, fittings, and tubing.

Kit No.

24T584

24T585

24T586

24T587

24T588

24T589

Kit Description

One non-circulating valve

(replaces a plug). Includes valve, solenoid, fittings, and tubing.

One circulating valve (replaces a plug). Includes valve, solenoid, fittings, and tubing.

Manifold with one non-circulating valve. Includes valve, plug, solenoid, fittings, and tubing.

Manifold with one circulating valve.

Includes valve, plug, solenoid, fittings, and tubing.

Manifold with two non-circulating valves. Includes valves, solenoids, fittings, and tubing.

Manifold with two circulating valves. Includes valves, solenoids, fittings, and tubing.

High Pressure Acid-Compatible Expansion Kits

Kit No.

24T590

24T591

24T592

Kit Description

One non-circulating acidcompatible valve (replaces a plug). Includes valve, solenoid, fittings, and tubing.

Manifold with one non-circulating acid-compatible valve. Includes valve, plug, solenoid, fittings, and tubing.

Manifold with two non-circulating acid-compatible valves. Includes valves, solenoids, fittings, and tubing.

64 332455E

Parts

IS Expansion Kits

The following kits are available to add color valves in an IS area. See

Install an Expansion Kit, page 28

for instructions.

Low Pressure Expansion Kits High Pressure Expansion Kits

Kit No.

24T449

24T450

24T451

24T452

24T453

24T454

Kit Description

One non-circulating valve

(replaces a plug). Includes valve,

IS solenoid, fittings, and tubing.

One circulating valve (replaces a plug). Includes valve, IS solenoid, fittings, and tubing.

Manifold with one non-circulating valve. Includes valve, plug, IS solenoid, fittings, and tubing.

Manifold with one circulating valve.

Includes valve, plug, IS solenoid, fittings, and tubing.

Manifold with two non-circulating valves. Includes valves, IS solenoids, fittings, and tubing.

Manifold with two circulating valves. Includes valves, IS solenoids, fittings, and tubing.

Kit No.

24T712

24T713

24T714

24T715

24T716

24T717

Kit Description

One non-circulating valve

(replaces a plug). Includes valve,

IS solenoid, fittings, and tubing.

One circulating valve (replaces a plug). Includes valve, IS solenoid, fittings, and tubing.

Manifold with one non-circulating valve. Includes valve, plug, IS solenoid, fittings, and tubing.

Manifold with one circulating valve.

Includes valve, plug, IS solenoid, fittings, and tubing.

Manifold with two non-circulating valves. Includes valves, IS solenoids, fittings, and tubing.

Manifold with two circulating valves. Includes valves, IS solenoids, fittings, and tubing.

High Pressure Acid-Compatible Expansion Kits

Kit No.

24T718

24T719

24T720

Kit Description

One non-circulating acidcompatible valve (replaces a plug). Includes valve, IS solenoid, fittings, and tubing.

Manifold with one non-circulating acid-compatible valve. Includes valve, plug, IS solenoid, fittings, and tubing.

Manifold with two non-circulating acid-compatible valves. Includes valves, IS solenoids, fittings, and tubing.

332455E 65

Dimensions

Dimensions

Figure 26 Non-IS Control Module

A

11.30 in. (1478 mm)

B

7.67 in. (195 mm)

C D

9.8 in. (249 mm) 5.70 in. (145 mm)

E F

0.31 in. (8 mm) 5.80 in. (147 mm)

Figure 27 IS Control Module

A

16.57 in. (421 mm)

B

8.22 in. (209 mm)

C

15.07 in. (383 mm)

D

6.70 in. (170 mm)

E F

0.31 in. (8 mm) 4.52 in. (115 mm)

66 332455E

NOTE: Total height of valve stack = H + K + (J x number of manifold blocks in your stack).

Dimensions

Figure 28 Manifold

G

1.80 in.

(46 mm)

0.48 in.

(12 mm)

1.50 in.

(38 mm)

2.00 in.

(51 mm)

H

0.61 in.

(15 mm)

J

1.66 in.

(42 mm)

K L M

Low Pressure Valve Manifolds

N

0.64 in.

(16 mm)

5.03 in.

(128 mm)

3.35 in.

(85 mm)

0.24 in.

(6 mm)

High Pressure Valve Manifolds

0.61 in.

(15 mm)

5.4 in.

(137 mm)

3.35 in.

(85 mm)

0.30

in. (7.6

mm)

P

0.32 in.

(8 mm)

0.28 in.

(7 mm)

0.30

in. (7.6

mm)

R

0.28 in.

(7 mm)

S

1/4 npt(m)

1/4 npt(m)

332455E 67

Dimensions

T

3.84 in. (98 mm)

U

11.44 in. (291 mm)

V

0.312 in. (8 mm) diameter

Figure 29 Manifold Mounting Bracket

68 332455E

Weights

Weights

Low Pressure Non-Circulating Valve Manifold Kits

24T471

24T472

24T473

24T474

24T475

24T476

24T477

24T478

24T479

24T480

24T481

24T482

24T483

24T484

24T485

24T486

Kit No.

24T457

24T458

24T459

24T460

24T461

24T462

24T463

24T464

24T465

24T466

24T467

24T468

24T469

24T470

8.17

9.08

9.07

9.98

9.96

10.88

10.86

11.77

11.75

12.67

12.65

13.56

13.54

14.46

14.44

15.35

6.38

7.29

7.28

8.19

3.69

4.61

4.59

5.50

5.48

6.40

lb

1.90

2.82

2.80

3.71

3706

4121

4112

4527

4519

4933

4925

5339

5331

5746

5737

6152

6143

6558

6550

6964

1675

2090

2081

2496

2488

2902

2894

3308

3300

3715 grams

863

1277

1269

1684

Low Pressure Circulating Valve Manifold Kits

24T501

24T502

24T503

24T504

24T505

24T506

24T507

24T508

24T509

24T510

24T511

24T512

24T513

24T514

24T515

24T516

Kit No.

24T487

24T488

24T489

24T490

24T491

24T492

24T493

24T494

24T495

24T496

24T497

24T498

24T499

24T500

9.03

10.00

10.03

11.00

11.04

12.00

12.04

13.01

13.04

14.01

14.04

15.01

15.05

16.01

16.05

17.02

7.02

7.99

8.03

8.99

4.02

4.98

5.02

5.99

6.02

6.99

lb

2.01

2.98

3.01

3.98

4096

4535

4551

4989

5005

5444

5460

5899

5915

6354

6370

6809

6825

7264

7280

7719

1821

2260

2276

2715

2731

3170

3186

3625

3641

4080 grams

912

1351

1366

1805

332455E 69

Weights

24T658

24T659

24T660

24T661

24T662

24T663

24T664

24T665

24T666

24T667

24T668

24T669

24T670

24T671

24T672

Kit No.

24T647

24T648

24T649

24T650

24T651

24T652

24T653

24T654

24T655

24T656

24T657

24T673

24T674

24T675

24T676

24T845 (acidcatalyzed)

24T846 (acidcatalyzed)

High Pressure Non-Circulating Valve Manifold Kits grams

3503

5210

5329

7036

7154

8861

8980

10687

10806

12512

12631

14338

14457

16163

16282

17989

18108

19814

19933

21640

21759

23465

23584

25291

25410

27117

27235

28942

29061

30768

5210

15.5

15.8

19.5

19.8

23.6

lb

7.7

11.5

11.7

23.8

27.6

27.8

31.6

31.9

35.6

35.9

39.7

39.9

51.7

52.0

55.8

56.0

59.8

43.7

43.9

47.7

48.0

60.0

63.8

64.1

67.8

11.5

15.5

7036

High Pressure Circulating Valve Manifold Kits grams

3508

5216

5337

7046

7167

8876

8997

10706

10826

12535

12656

14365

14486

16195

16316

18024

18145

19854

19975

21684

21805

23514

23634

25343

25464

27173

27294

29003

29124

30832

15.5

15.8

19.6

19.8

23.6

lb

7.7

11.5

11.8

23.9

27.6

27.9

31.7

31.9

35.7

36.0

39.7

40.0

51.8

52.1

55.9

56.1

59.9

43.8

44.0

47.8

48.1

60.2

63.9

64.2

68.0

24T698

24T699

24T700

24T701

24T702

24T703

24T704

24T705

24T706

24T688

24T689

24T690

24T691

24T692

24T693

24T694

24T695

24T696

24T697

Kit No.

24T677

24T678

24T679

24T680

24T681

24T682

24T683

24T684

24T685

24T686

24T687

70 332455E

Non-IS Color Change Control Modules

Kit No.

24T557

24T558

24T559

24T560 lb

9.7

10.1

10.5

10.9

grams

4386

4576

4766

4956

Non-IS Color Change Control Modules

Kit No.

24T571

24T572

24T573

24T574 lb

9.1

9.4

9.7

10.0

grams

4122

4266

4409

4553

Weights

332455E 71

Notes

Notes

72 332455E

Technical Data

Technical Data

Color Change Kits

Maximum fluid working pressure:

U.S.

Metric

Low pressure kits

High pressure kits

Maximum working air pressure:

Air supply:

Viscosity range of fluid:

Fluid inlet size:

Fluid outlet size:

Air inlet size:

Weights:

300 psi

1500 psi

100 psi

85–100 psi

2.1 MPa, 21 bar

10.5 MPa, 105 bar

0.7 MPa, 7.0 bar

0.6–0.7 MPa, 6.0–7.0 bar

20–5000 centipoise

1/4 npt(f)

1/4 npt(f)

5/32 in. OD tube

See

Weights, page 69 .

4 mm OD tube

Wetted parts:

Valve manifold Glass-filled polyphenylene sulfide, 316 SST, PTFE, chemically resistant o-rings

Valve See valve manual 332454.

332455E 73

Graco Standard Warranty

Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use.

twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be with Graco’s written recommendations.

damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.

This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized

Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.

buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost

Any action for breach of warranty must be brought within two (2) years of the date of sale.

their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.

In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.

FOR GRACO CANADA CUSTOMERS

The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en en rapport, directement ou indirectement, avec les procédures concernées.

Graco Information

For the latest information about Graco products, visit www.graco.com.

For patent information, see www.graco.com/patents.

To place an order, contact your Graco Distributor or call to identify the nearest distributor.

Phone: 612-623-6921 or Toll Free: 1-800-328-0211 Fax: 612-378-3505

All written and visual data contained in this document reflects the latest product information available at the time of publication.

Graco reserves the right to make changes at any time without notice.

Original Instructions. This manual contains English. MM 332455

Graco Headquarters: Minneapolis

International Offices: Belgium, China, Japan, Korea

GRACO INC. AND SUBSIDIARIES • P.O. BOX 1441 • MINNEAPOLIS MN 55440-1441 • USA

Copyright 2013, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.

www.graco.com