Graco 3A4403A, 6 Channel Upgrade Kit for InvisiPac Hot Melt Delivery Systems Instructions

Graco 3A4403A, 6 Channel Upgrade Kit for InvisiPac Hot Melt Delivery Systems Instructions | Manualzz
Instructions
6 Channel Upgrade Kit for
InvisiPac™ Hot Melt Delivery Systems
For upgrading a 4 channel system to a 6 channel system. For professional use only.
Not approved for use in explosive atmospheres or hazardous locations.
Important Safety Instructions
Read all warnings and instructions in this manual and
in the InvisiPac Hot Melt Delivery System manual.
Save all instructions.
4 Channel Upgrade Kit 24V529
3A4403A
EN
6 Channel Upgrade Kit, 24V529
6 Channel Upgrade Kit, 24V529
Use this kit to upgrade a 4 channel system to a 6 channel system.
1304
1308
1302
WLD
1307
1306
1303
1305
1301
Ref.
1301
1302
1303
1304
1305
1306
1307
1308
2
Part
24V510
16T087
112190
24R324
16T440
127425
16W035
127208
116793
126961
Description
Qty.
MODULE, GCA, MZLP
1
CABLE, jumper, male/male, 4 in.
1
STRAP, wrist, grounding
1
TOKEN, software upgrade
1
CAP, jam nut, sealing
2
HARNESS, MZLP #3
1
CONNECTOR, jumper
1
FITTING, tee
2
FITTING, 90° elbow (not shown)
2
FITTING, 45° elbow (not shown)
2
3A4403A
6 Channel Upgrade Kit Installation
6 Channel Upgrade Kit Installation
6. Remove electrical enclosure front access door.
NOTE: Do not force the electrical connection. Minimal force is required to seat the connector. If resistance is felt, stop and verify the connector
orientation. Verify the connector has “Locked” by
gently pulling on the white connector housing.
The equipment must be grounded. Improper grounding, setup, or usage of the system can cause electric
shock. Disconnect the plug from the power outlet or
turn off the circuit breaker for incoming power.
7. Connect CAN jumper cable (1302) to MZLP 2 connector J3 and connect other end of jumper
cable (1302) to MZLP 3 connector J3.
Equipment surfaces and fluid that is heated can
become very hot during operation. To avoid severe
burns, do not touch hot fluid or equipment.
8. Install jumper connector (1307) in J5 on MZLP 3.
1. Perform the Pressure Relief Procedure (see the
InvisiPac manual).
9. Connect wires from power harness (1306) between
AWB connector J5 and MZLP connector J2.
2. Place grounding wrist strap (1303) over your wrist
and secure other end to a grounded surface.
10. Remove plugs (CC) from fluid manifold and replace
with straight fittings (1309), tee fittings (1308), or the
extra fittings included with the InvisiPac system.
Use the fittings that meet your hose routing needs.
3. Set the kit’s MZLP (1301) rotary switch to “3”.
4. Remove screws (BB) then remove plate (AA) from
system.
5. Use screws (BB) to install MZLP (1301) onto system.
11. To ensure your InvisiPac system has the latest software, insert token (1306) into the ADM. Follow the
Software Update Procedure in the InvisiPac manual.
NOTE: The new MZLP (1301) will be referred to as
MZLP 3, and the original MZLPs that came with the
system will be referred to as MZLP 1 and MZLP 2
from here on.
0=/3
0=/3
-
0=/3
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Step 7: Install jumper cable (1302).
WLD
3A4403A
3
Graco Information
For more information about InvisiPac, visit www.InvisiPac.com.
For technical assistance or customer service, call toll free: 1-800-458-2133.
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
Original instructions. This manual contains English. MM 3A4403
Graco Headquarters: Minneapolis
International Offices: Belgium, China, Japan, Korea
GRACO INC. AND SUBSIDIARIES • P.O. BOX 1441 • MINNEAPOLIS MN 55440-1441 • USA
Copyright 2016, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.
www.graco.com
Revision A, October 2016