Graco 308332D Monark Sprayers Owner's Manual

Add to my manuals
16 Pages

advertisement

Graco 308332D Monark Sprayers Owner's Manual | Manualzz

INSTRUCTIONS-PARTS LIST

INSTRUCTIONS

This manual contains important warnings and information.

READ AND KEEP FOR REFERENCE.

308–332

First choice when quality counts.

Rev. D

Supersedes Rev. C and PCN D

STAINLESS STEEL, 15:1 RATIO

Monark Sprayers

2700 psi (18.5 MPa, 185 bar) Maximum Fluid Working Pressure

180 psi (1.25 MPa, 12.5 bar) Maximum Air Inlet Pressure

Part No. 236–065

Wall Mount Pump

With Fluid Regulator

Part No. 236–898

Wall Mount Pump

Without Fluid Regulator

Part No. 236–069

Pail Mounted Pump

With Fluid Regulator

Part No. 236–900

Pail Mounted Pump

Without Fluid Regulator

GRACO INC.

P.O. BOX 1441 MINNEAPOLIS, MN 55440–1441

http://www.graco.com

COPYRIGHT 1993, GRACO INC.

Graco Inc. is registered to I.S. EN ISO 9001

Table of Contents

Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Installation

Operation

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

8

10

2

5

Technical Data

Warranty

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Graco Phone Number . . . . . . . . . . . . . . . . . . . . . . . . . .

15

16

16

Symbols

Warning Symbol

WARNING his symbol alerts you to the possibility of serious injury or death if you do not follow the corresponding instructions.

Caution Symbol

CAUTION

This symbol alerts you to the possibility of damage to or destruction of equipment if you do not follow the corresponding instructions.

INSTRUCTIONS

EQUIPMENT MISUSE HAZARD

Equipment misuse can cause the equipment to rupture or malfunction and result in serious injury.

Read all instruction manuals, tags, and labels before operating the equipment.

Use the equipment only for its intended purpose. If you are uncertain about usage, call your

Graco distributor.

Do not alter or modify this equipment. Use only genuine Graco parts and accessories.

Check equipment daily. Repair or replace worn or damaged parts immediately.

Do not exceed the maximum working pressure of the lowest rated system component. This equipement has a 2700 psi (18.5 MPa, 185 bar) maximum working pressure at 180 psi (1.25

MPa, 12.5 bar) maximum air inlet pressure.

Use fluids and solvents which are compatible with the equipment wetted parts. Refer to the

Technical Data section of all equipment manuals. Read the fluid and solvent manufacturer’s warnings.

Do not use hoses to pull equipment.

Route hoses away from traffic areas, sharp edges, moving parts, and hot surfaces. Do not expose Graco hoses to temperatures above 82 C (180 F) or below –40 C (–40 F).

Do not lift pressurized equipment.

Wear hearing protection when operating this equipment.

Comply with all applicable local, state, and national fire, electrical, and safety regulations.

INJECTION HAZARD

Spray from the gun, hose leaks, or ruptured components can inject fluid into your body and cause extremely serious injury, including the need for amputation. Fluid splashed into the eyes or onto the skin can also cause serious injury.

Fluid injected into the skin might look like just a cut, but it is a serious injury. Get immediate medical attention.

Do not point the gun at anyone or at any part of the body.

Do not put your hand or fingers over the spray tip.

Do not stop or deflect leaks with your hand, body, glove or rag.

Do not “blow back” fluid; this is not an air spray system.

Always have the tip guard and the trigger guard on the gun when spraying.

Check the gun diffuser operation weekly. Refer to the gun manual.

Be sure the gun trigger safety operates before spraying.

Lock the gun trigger safety when you stop spraying.

Follow the Pressure Relief Procedure on page 8 whenever you: are instructed to relieve pressure; stop spraying; clean, check, or service the equipment; and install or clean the spray tip.

Tighten all fluid connections before operating the equipment.

Check the hoses, tubes, and couplings daily. Replace worn or damaged parts immediately. Do not repair high pressure couplings; you must replace the entire hose.

Fluid hoses must have spring guards on both ends, to help protect them from rupture caused by kinks or bends near the couplings.

TOXIC FLUID HAZARD

Hazardous fluid or toxic fumes can cause serious injury or death if splashed into the eyes or onto the skin, inhaled, or swallowed.

Know the specific hazards of the fluid you are using.

Store hazardous fluid in an approved container. Dispose of hazardous fluid according to all local, state, and national guidelines.

Always wear protective eyewear, gloves, clothing, and a respirator as recommended by the fluid and solvent manufacturer.

FIRE AND EXPLOSION HAZARD

Improper grounding, poor ventilation, open flames, or sparks can cause a hazardous condition and result in a fire or explosion and serious injury.

Ground the equipment and the object being sprayed. Refer to Grounding on page 5.

If there is any static sparking or you feel an electric shock while using this equipment, stop

spraying immediately. Do not use the equipment until you identify and correct the problem.

Provide fresh air ventilation to avoid the buildup of flammable fumes from solvents or the fluid being sprayed.

Keep the spray area free of debris, including solvent, rags, and gasoline.

Electrically disconnect all equipment in the spray area.

Extinguish all open flames or pilot lights in the spray area.

Do not smoke in the spray area.

Do not turn on or off any light switch in the spray area while operating or if fumes are present.

Do not operate a gasoline engine in the spray area.

MOVING PARTS HAZARD

Moving parts, such as the air motor piston, can pinch or amputate your fingers.

Keep clear of all moving parts when starting or operating the pump.

Before servicing the equipment, follow the Pressure Relief Procedure on page 8 to prevent the equipment from starting unexpectedly.

4 308-332

Grounding

Installation

5.

Spray gun: grounding is obtained through connection to a properly grounded fluid hose and pump.

WARNING

FIRE AND EXPLOSION HAZARD

Before operating the pump, ground the system as explained below. Also read the section FIRE AND EXPLOSION

HAZARD on page 4.

6.

Fluid supply container: according to your local code.

7.

Object being sprayed: according to your local code.

8.

All solvent pails used when flushing, according to local code. Use only metal pails, which are conductive, placed on a grounded surface. Do not place the pail on a non-conductive surface, such as paper or cardboard, which interrupts the grounding continuity.

To reduce the risk of static sparking, ground the pump.

Check your local electrical code for detailed grounding instructions for your area and type of equipment. Be sure to ground all of this dispensing equipment.

1.

Pump: loosen the grounding lug locknut (W) and washer (X). Insert one end of a 1.5 mm

2

(12 ga) minimum ground wire (Y) into the slot in lug (Z) and tighten the locknut securely. See Fig. 1. Connect the other end of the ground wire to a true earth ground.

2.

Air hoses: use only electrically conductive air hoses.

3.

Fluid hoses: use only electrically conductive fluid hoses.

4.

Air compressor: follow manufacturer’s recommendations.

9.

To maintain grounding continuity when flushing or relieving pressure, always hold a metal part of the spray gun firmly to the side of a grounded metal pail, then trigger the spray gun.

Fig. 1

W

X

Z

Y

308-332 5

Installation

Wall Mount Pump

Be sure that all operators read and understand this entire manual and the separate manuals supplied with components and accessories before using this equipment.

Reference numbers and letters in parentheses refer to the figures and the parts lists on pages 10–13.

Accessories mentioned are available from your Graco distributor. If you supply your own accessories, be sure they are adequately sized to meet your system’s requirements.

The Typical Installation shown in Fig. 3 is only an example. For assistance in designing a system to meet your particular needs, contact your Graco distributor.

System Accessories

Mount the wall bracket 5 ft (1.5 m) above the floor. Be sure the wall is strong enough to support the weight of the pump and accessories, fluid, hoses, and stress caused during pump operation. See Fig. 2 for a bracket mounting hole pattern.

5 in. (127 mm)

6.26 in.

(159 mm)

Four 0.47

in. (12 mm) diameter holes

WARNING

Two required components are supplied with your pump, to help reduce the risk of serious injury including fluid injection, splashing in the eyes or on the skin, or injury from moving parts if you are adjusting or repairing the pump.

The bleed-type master air valve (B) relieves air trapped between this valve and the pump. Trapped air can cause the pump to cycle unexpectedly. To bleed air from the pump, the pump air regulator (F) must be open when you close this valve.

The fluid drain valve (H) assists in relieving fluid pressure in the displacement pump, hose, and gun; triggering the gun to relieve pressure may not be sufficient.

Fig. 2

Hose and Gun Connections

Refer to Fig. 3. Apply thread sealant and screw the suction hose (J) into the fluid intake elbow (S).

On models with a fluid regulator (R), connect one end of the fluid hose (L) to the fluid regulator outlet. On models without fluid regulators, connect one end of the fluid hose (L) to the outlet of the fluid filter (K). Connect the other end of the fluid hose (L) to the fluid inlet of the spray gun (N). Do not install the spray tip in the gun yet.

Install an air line filter (E) in the main air line, to remove harmful dirt and moisture from the compressed air supply. To provide automatic lubrication of the air motor, install an air line lubricator (P) downstream from the pump air regulator (F). Install a second master air valve (D) in the main air line, to isolate the accessories for servicing.

Close the bleed-type master air valve (B) and the air regulators (F and G). Connect a grounded air hose (M) between the outlet of the gun air regulator (G) and the air inlet of the spray gun (N). The pump air regulator

(F) is connected to the pump (A) with a hose (C).

6 308-332

Typical Installation –

Model 236–067 Shown

KEY

A Pump

B Bleed-Type Master Air Valve

(required for pump)

C Air Supply Line

D Master Air Valve (for accessories)

E Air Line Filter

F Pump Air Regulator

G Gun Air Regulator

H Fluid Drain Valve (required)

J Fluid Suction Line

K Fluid Filter

L Gun Fluid Supply Hose

M Gun Air Supply Hose

N Air-Assisted Airless Spray Gun

P Air Line Lubricator

R Fluid Pressure Regulator

S Fluid Intake Elbow

Y Ground Wire (required; see page 5 for installation instructions)

N

L

A

Y

R

Installation

NOTE: Some components shown are included with the sprayer, depending on the model. Refer to the parts lists on pages 10–13 for parts included in your sprayer.

D E

F

M

L

G

M

K

H

B S

J

C

P

Fig. 3

308-332 7

Pressure Relief Procedure

WARNING

INJECTION HAZARD

Fluid under high pressure can be injected through the skin and cause serious injury. To reduce the risk of an injury from injection, splashing fluid, or moving parts, follow the Pressure Relief Procedure whenever you: are instructed to relieve the pressure, stop spraying, check or service any of the system equipment, or install or clean the spray tips.

Operation

Flush the Pump Before Using

Pumps are tested with lightweight oil which is left in to protect the pump parts. To prevent contamination of the fluid, flush the pump with a compatible solvent before using it.

WARNING

Before flushing, be sure the entire system and flushing pails are properly grounded. Refer to

Grounding on page 5. Follow the Pressure

Relief Procedure at left, and remove the spray tip from the gun. Always use the lowest possible fluid pressure, and maintain firm metal-to-metal contact between the gun and the pail during flushing to reduce the risk of fluid injection, static sparking, and splashing in the eyes or on the skin.

1.

Lock the spray gun trigger safety.

2.

Close the bleed-type master air valve (supplied in your system).

3.

Shut off the air regulators.

Starting and Adjusting the Pump

WARNING

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the

Pressure Relief Procedure on page 8.

4.

Unlock the spray gun trigger safety.

5.

Hold a metal part of the spray gun firmly to the side of a grounded metal pail, and trigger the spray gun to relieve pressure.

6.

Lock the spray gun trigger safety.

7.

Open the drain valve (supplied in your system), having a container ready to catch the drainage.

See Fig. 4. Be sure the air regulators (10a and 10b) and bleed-type master air valve (16) are closed. Do not install the spray tip yet!

8.

Leave the drain valve open until you are ready to spray again.

If you suspect that the spray tip or hose is completely clogged, or that pressure has not been fully relieved after following the steps above, very slowly loosen the tip guard retaining nut or hose end coupling and relieve pressure gradually, then loosen completely. Now clear the tip or hose.

WARNING

For your safety, before operating the equipment be sure all operators have read and fully understand all the warnings, cautions, and instructions in this manual and all manuals supplied with each component or accessory.

On cart mount units, place the suction tube (21) in the fluid container.

On wall mount units, screw the bung adapter (34) into the container’s bung hole, slide the suction tube through the adapter into the container, and tighten the thumbscrew (33) to secure. Position the tube so its end is about 1/2 in. (13 mm) off the bottom of the container.

On pail mount units, fill the pail (40) with fluid. Set the cover (1) on the pail and secure with the thumbscrews

(42).

Open the drain valve (6) to prime the pump. Open the bleed-type master air valve (16). Open the gun air regulator (10a). Hold a metal part of the spray gun firmly to the side of a grounded metal pail and trigger the gun.

Continued on page 9.

Operation

Slowly open the pump air regulator (10b) until the pump starts. Run the pump slowly until fluid comes from the drain valve (6). Close the drain valve and continue to run the pump until all the air is pushed out of the fluid lines. Release the gun trigger and lock the safety latch; the pump will stall against the pressure.

With the pump and lines primed, and with adequate air pressure and volume supplied, the pump will start and stop as the spray gun is triggered and released.

Never allow the pump to run dry of the fluid being pumped. A dry pump will quickly accelerate to a high speed, possibly damaging itself. If your pump accelerates quickly, or is running too fast, stop it immediately and check the fluid supply. If the supply container is empty and air has been pumped into the lines, refill the supply container and prime the pump and lines with fluid, being sure to eliminate all air from the fluid system, or flush the pump as described in Shutdown and

Care, at right.

Relieve the pressure, then install the spray tip in the gun.

Use the pump air regulator (10b) to control the pump speed and fluid pressure. On models with a fluid pressure regulator (29), use it for more precise control of pressure at the gun. Always use the lowest pressure necessary to achieve the desired results. Higher pressures waste fluid and cause premature wear of the pump packings and spray tip.

Keep the packing nut/wet-cup filled with Graco Throat

Seal Liquid (TSL) to help prolong the packing life.

Check the tightness of the packing nut weekly. The packing nut should be tight enough to prevent leakage

– no tighter. Always relieve the pressure before adjusting the packing nut.

Shutdown and Care

WARNING

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the

Pressure Relief Procedure on page 8.

Relieve the pressure whenever you shut off the pump. Stop the pump at the bottom of its stroke to keep fluid from drying on the exposed displacement rod and damaging the throat packings.

Always flush the pump with a compatible solvent before the fluid can dry on the displacement rod, and at the end of each day. Relieve pressure after flushing.

Wall Mount Pumps

(Model 236–065)

29

10a

Pail Mount Pumps

(Model 236–069)

16

6

34

10b

21

16

10b

29

40

10a

1

42

6

Fig. 4

Parts

Part No. 236–065

Wall Mount Pump with Fluid Regulator

Includes items 1–50

Part No. 236–898

Wall Mount Pump without Fluid Regulator

Includes items 1–28, 43–50

1 See Detail at left.

2

Apply thread sealant to male threads, except at swivel connections.

2 39 (REF) 2 43

2

7 2

26

B

5

1

2 39 33

29 2 30

B

2 6 25

24

2

2

31

38

32

25

36

34

35

47

2 18

2 19

2

28

14

2 15

16

1

1 (REF)

12 2

8 9 2

10 11 2

B

17 2

13 (REF)

A

23

1

13

22 2

20 2

A

21

45

44

02802A

10 308-332

Parts

1

2

Part No. 236–065

Wall Mount Pump with Fluid Regulator

Includes items 1–50

Part No. 236–898

Wall Mount Pump without Fluid Regulator

Includes items 1–28, 43–50

Ref.

No.

Part No.

Description Qty.

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

186–727 BRACKET, wall mounting

223–844 MONARK PUMP; stainless steel

1

See 308–106 for parts

223–160 FLUID FILTER; stainless steel

See 307–273 for parts

235–992 BALL VALVE; 3/8 npt x 1/4 npt (mbe);

1

1 stainless steel; see 306–861 for parts 1

188–089 NIPPLE; 3/8 npt x 3/8–18.6 sf; stainless steel 1

179–749 MANIFOLD, air; 1/2 npt inlet; two 1/2 npt outlets

156–877 NIPPLE; 1/2 npt; 2.5” (63.5 mm)

104–267 AIR REGULATOR

0–125 psi (0–0.9 MPa, 0–9 bar) range

See 308–167 for parts

161–037 UNION, adapter, 90 ;

2

1/2 npt(m) x 3/8 npsm(f) swivel

101–180 GAUGE, air pressure;

0–200 psi (0–1.4 MPa, 0–14 bar)

204–560 HOSE, air; buna-N; 3/8” (10 mm) ID;

1

2 cpld 3/8 npt(mbe); 18” (457 mm) long 1

222–297 UNION, adapter, 45 ;

1

2

1/2 npt(m) x 1/2 npsm(f) swivel 1

158–491 NIPPLE; 1/2 npt; 1.625” (41 mm) long 1

107–142 VALVE, air, bleed-type;

1/2 npt (m x f) 1

161–356 UNION, adapter, 45 ;

3/8 npt(m) x 3/8 npsm(f) swivel

166–999 ELBOW, street, reducing;

1

1

1

1/2 npt(m) x 1/4 npt(f)

162–453 NIPPLE; 1/4 npt x 1/4 npsm

236–076 HOSE, suction, fluid; nylon;

3/4 npt(mbe); 3/4” (19 mm) ID;

6 ft (1.82 m) long

188–867 TUBE, suction; 3/4 npt (m x f); stainless steel

1

1

112–192 ELBOW, fluid intake; 3/4 npt(fbe); stainless steel 1

43

44

45

47

50

28

29

30

Ref.

No.

23

24

25

26

34

35

36

38

39

31

32

33

Part No.

Description Qty.

188–595 BRACKET, pump mounting

100–015 NUT, hex; 1/4–20

100–016 LOCKWASHER, spring; 1/4”

100–022 CAPSCREW, hex hd;

1/4–20 x 3/4” (19 mm) long

100–509 PLUG, pipe; 1/4 npt

222–121 FLUID PRESSURE REGULATOR

See 307–886 for parts

112–564 GAUGE, fluid pressure; 1/4 npt(m);

0–1500 psi

(0–10.6 MPa, 0–105 bar) range

112–168 CROSS; 1/4 npt(m) x 1/4 npsm(m) x two 1/4 npt(f); stainless steel

185–251 BRACKET, fluid regulator

100–469 CAPSCREW, hex hd;

3/8–16 x 3/4” (19 mm) long

100–133 LOCKWASHER; 3/8”

100–307 NUT, hex; 3/8–16 unc

100–270 CAPSCREW, hex hd;

1/4–20 x 5/8” (16 mm) long

111–697 PLUG; 1/4 npt; stainless steel

112–281 HOSE, fluid; PTFE; 1/4” (6.3 mm) ID:

1/4 npt(mbe) sst couplings;

18” (457 mm) long

235–208 UNION, swivel;

3/8 npt(m) x 3/8 npsm(f)

100–220 THUMBSCREW; 5/16–18 unc;

1” (25 mm) long

188–940 ADAPTER, bung; stainless steel

102–254 SCREW, hex hd; 1/4–20 x

7/8” (22 mm) long

206–994 T HROAT SEAL LIQUID

(not shown)

2

2

1

2

4

1

1

1

1

2

1

1

1

1

1

1

1

1

2

1

Pump 236–898 Uses only Qty: 2 of 100–016.

308-332 11

Part No. 236–069

Pail Mounted Pump with Fluid Regulator

Includes items 1–50

Parts

Part No. 236–900

Pail Mounted Pump without Fluid Regulator

Includes items 1–28, 33, 40–50

14

12

13 (REF)

27

16

A

10

28

9

2

28

8

12

10

18

19

29

30

31

38

39

B

33

32

5

6

39 (REF)

37 36

B

25

24

43 7

A

13

21

23

49

25

24

1

42

48

40

Torque to 25–30 ft–lb (34–41 N.m).

Apply thread sealant to male threads, except at swivel connections.

12 308-332

Part No. 236–069

Pail Mounted Pump with Fluid Regulator

Includes items 1–50

Parts

18

19

21

23

6

7

8

13

14

16

Part No. 236–900

Pail Mounted Pump without Fluid Regulator

Includes items 1–28, 33, 40–50

1

2

Ref.

No.

5

9

10

12

24

25

Part No.

Description Qty.

236–244 COVER, pail; stainless steel

223–844 MONARK PUMP; stainless steel

See 308–106 for parts

223–160 FLUID FILTER; stainless steel

1

1

See 307–273 for parts

235–992 BALL VALVE; 3/8 npt x 1/4 npt (mbe); stainless steel

188–979 MANIFOLD, air; 1/2 npt(m) x

1 stainless steel; see 306–861 for parts 1

188–089 NIPPLE; 3/8 npt x 3/8–18.6 sf;

1

1 two 1/4 npt(f) ports

159–239 NIPPLE; 1/2 x 3/8 npt;

1.625” (41.28 mm)

104–267 AIR REGULATOR

0–125 psi (0–0.9 MPa, 0–9 bar) range

See 308–167 for parts

101–180 GAUGE, air pressure;

1

2

0–200 psi (0–1.4 MPa, 0–14 bar)

112–280 HOSE, air; buna-S; 1/4” (6.3 mm) ID;

1/4 npt(mbe); 18” (457 mm) long

222–297 UNION, adapter, 45 ;

1/2 npt(m) x 1/2 npsm(f) swivel

107–142 VALVE, air, bleed-type;

1/2 npt (m x f)

166–999 ELBOW, street, reducing;

1/2 npt(m) x 1/4 npt(f)

162–453 NIPPLE; 1/4 npt x 1/4 npsm

188–984 TUBE, suction; 3/4 npt(m); stainless steel

188–978 PLATE, pump mounting;

2

1

1

1

1 stainless steel

110–271 NUT, cap; 3/8–16; stainless steel

110–273 LOCKWASHER; 3/8”; stainless steel 5

1

4

1

1

Ref.

No.

27

28

29

30

31

32

33

36

37

38

39

40

41

42

43

46

48

49

50

Part No.

Description Qty.

112–262 TEE; 1/2 npt(m) x 1/4 npt(f) run;

1/2 npt(m) branch

100–509 PLUG, pipe; 1/4 npt

222–121 FLUID PRESSURE REGULATOR

See 307–886 for parts

112–564 GAUGE, fluid pressure; 1/4 npt(m);

0–1500 psi

(0–10.5 MPa, 0–105 bar) range

112–168 CROSS; 1/4 npt(m) x 1/4 npsm(m) x two 1/4 npt(f); stainless steel

185–251 BRACKET, fluid regulator

100–469 CAPSCREW, hex hd;

3/8–16 x 3/4” (19 mm) long

100–270 CAPSCREW, hex hd;

1/4–20 x 5/8” (16 mm) long

100–016 LOCKWASHER, spring; 1/4”

111–697 PLUG; 1/4 npt; stainless steel

112–281 HOSE, fluid; PTFE; 1/4” (6.3 mm) ID:

1/4 npt(mbe) sst couplings;

18” (457 mm) long

101–108 PAIL

111–747

111–276

PLUG, plastic (not shown)

THUMBSCREW; 5/16–18 x

1” (25 mm); stainless steel

235–208 UNION, swivel;

3/8 npt(m) x 3/8 npsm(f)

188–981 PLUG, agitator port (not shown)

112–263 TUBE, fluid, with 3/8 npt(m) elbow; stainless steel

101–962 SETSCREW

206–994 THROAT SEAL LIQUID

(not shown)

1

3

1

1

1

1

1

2

2

1

1

1

1

3

1

1

1

2

1

308-332 13

14 308-332

Notes

Technical Data

Category

Maximum working pressure

Maximum incoming air pressure

Ratio

Wetted parts: Pump

Wetted parts: Fluid Hose

Wetted parts: Fluid Filter

Wetted parts: Suction Hose and Tube

Wetted parts: Fluid Fittings

Data

2700 psi (18.5 MPa, 185 bar)

180 psi (1.25 MPa, 125 bar)

15”1

See manual 308–106

Nylon

See manual 307–273

Nylon, 304, Stainless Steel

304 and 316 Stainless Steel

Manual Change Summary

This manual was revised to include the changes from PCN D.

Models 236–067 and 236–899 are obsolete and are removed from this manual.

308-332 15

Graco Warranty

Graco warrants all equipment listed in this manual which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale by an authorized Graco distributor to the original purchaser for use. With the exception of any special extended or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations.

This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of

Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance or structures, accessories, equipment or materials not supplied by Graco.

This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.

Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.

GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR

A PARTICULAR PURPOSE IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT

NOT MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, gas engines, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.

In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.

FOR GRACO CANADA CUSTOMERS

The parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés à la suite de ou en rapport, directement ou indirectement, avec les procédures concernées.

Graco Phone Number

TO PLACE AN ORDER, contact your Graco distributor, or call this number to identify the distributor closest to you:

1–800–367–4023 Toll Free.

All written and visual data contained in this document reflects the latest product information available at the time of publication.

Graco reserves the right to make changes at any time without notice.

Sales Offices: Minneapolis, Detroit, Los Angeles

Foreign Offices: Belgium, Canada, England, Korea, France, Germany, Hong Kong, Japan

GRACO INC.

P.O. BOX 1441 MINNEAPOLIS, MN 55440–1441

http://www.graco.com

PRINTED IN U.S.A. 308–332 July 1994, Revised August 1997

16 308-332

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement