Trane T2GX049TLR11N1A XL Series T2GX 4 Tons Two-Stage Upflow and Vertical 1/2 hp Air Handler Specification
Advertisement
Advertisement
Geothermal/Water Source
Heat Pump
Product Data
• 2 - 6 Tons Single Stage
• 2 - 6 Tons Dual Stage
XL Series T1GX, T2GX
022-1853-6
SC2500AG4
T1GX, T2GX SERIES SPECIFICATION CATALOG
Table of Contents
The TGX Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Model Nomenclature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
AHRI/ISO 13256-1 Performance Ratings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-7
TGX Design Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-11
Microprocessor Control System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12-15
Operation Logic Data Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Water Quality . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Dimensional Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18-21
Physical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22-23
Auxiliary Heat Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Auxiliary Heat Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25-26
Blower Performance Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27-31
Reference Calculations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Legend and Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Operating Limits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Antifreeze Corrections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Correction Factor Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Pressure Drop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Performance Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37-63
Wiring Schematics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64-71
Engineering Guide Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72-74
Revision Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
3
T1GX, T2GX SERIES SPECIFICATION CATALOG
TGX Series
The TGX Series products established a new industry standard for effi ciency, performance, reliability and quiet operation. The performance with advanced controls and updated performance. with scroll (rotary in 012 and 018) compressors. The product is capacity compressors. bridge the gap of high effi ciency ECM capability with great value. ECM blowers are used to increase comfort, effi ciency, and airfl ow fl exibility. A sophisticated microprocessor control sequences all components during operation for optimum performance, and provides easy-to-use troubleshooting features with fault lights and on-board diagnostics. Unit confi gurations include vertical top, bottom, or rear discharge (left or right return) and horizontal units with left or right return a side or end discharge. Heavy-gauge metal cabinets are fully insulated and coated with an attractive and durable powder coat paint for long lasting protection.
TGX Series products are performance-certifi ed to AHRI/ISO 13256-1 standards, ETL listed, ENERGY STAR® qualifi ed, and tested in an ISO 17025 accredited testing lab.
As a leader in the industry, we are dedicated to innovation, quality, and customer satisfaction. In fact, every unit built is exposed to a wide range of quality control procedures throughout the assembly process in our ISO 9001:2008 certifi ed manufacturing facility.
At the end, it is subjected to a rigorous battery of computerized run tests to certify that it meets or exceeds performance standards for effi ciency and safety, and will perform fl awlessly at startup. As further affi rmation of our quality standards, each unit carries our exclusive Quality Assurance emblem, signed by the fi nal test technician.
4
T1GX, T2GX SERIES SPECIFICATION CATALOG
Model Nomenclature
Nomenclature: Envirowise Single and Dual-Stage Packaged Drawing Number:96D606-04
1
T
2
1
Model
T – Envirowise
Compressor Type
1 – Single Speed
2 – Dual Capacity
Product Category
G – Geothermal
Product Type
X – Premium Packaged System
Unit Capacity
012, 018, 022, 026, 030
036, 038, 042, 048, 049
060, 064, 070, 072
Discharge Configuration
T – Top (Vertical)
S – Side (Horizontal)
E – End (Horizontal)
B – Bottom (Vertical 022-072)
R – Rear (Vertical 042-072)
Air Configuration
L – Left
R – Right
3
G
4
X
5-7
042
8
T
9
L
10
R
11
1
12
0
13
C
14
1
15
*
Notes:
1 – HWG available 018-072
2 – IntelliStart available 022-072
Vintage
* - Factory Use Only
Blower Option
0 - PSC
1 – Variable Speed ECM (018-072)
2 – High Static Variable Speed ECM
(036-049)
4 – 5-Speed ECM (022-072)
Water Coax
C – Copper
N – CuproNickel
Hot Water Generation Option
0 – No HWG, No IntelliStart
1 – HWG with Factory Installed Pump,
No IntelliStart
1
3 – No HWG, IntelliStart
2
4 – HWG with Factory Installed Pump,
IntelliStart
1, 2
Voltage
1 – 208-230/60/1
Heating and/or Cooling
R – Heating and Cooling (Reversible)
Rev.:11/16/2016
5
T1GX, T2GX SERIES SPECIFICATION CATALOG
AHRI/ISO 13256-1 Performance Ratings
Variable Speed ECM or 5-Speed ECM Motor
AHRI/ASHRAE/ISO 13256-1
English (IP) Units
Water Loop Heat Pump Ground Water Heat Pump
Model
Capacity
Modulation
Flow Rate Cooling
EWT 86° F
Heating
EWT 68° F
042
048
060
070
018
022
030
036
026
026
038
038
049
049
064
064
072
072
Full
Part
Full
Part
Full
Part
Full
Part
Full
Part
Single
Single
Single
Single
Single
Single
Single
Single gpm
8
7
9
8
12
11
16
14
18
16
5
8
8
9
11
12
15
18 cfm
950
750
1300
1150
1600
1400
1800
1500
2000
1500
600
800
1000
1200
1300
1500
1800
2000
Capacity
Btuh
24,900
18,900
36,500
26,500
49,100
36,300
62,300
45,800
70,100
54,200
17,400
18,100
27,000
32,300
39,000
44,100
61,100
66,200
NOTE: 018 not available with 5-Speed ECM motor
Cooling capacities based upon 80.6°F DB, 66.2°F WB entering air temperature
Heating capacities based upon 68°F DB, 59°F WB entering air temperature
All ratings based upon 208V operation
EER
Btuh/W
15.7
15.6
18.9
18.8
18.6
16.3
16.4
15.3
16.8
18.6
17.0
19.0
17.2
19.1
16.4
18.1
15.6
17.0
Capacity
Btuh
23,000
23,700
32,900
36,500
45,600
55,600
74,100
85,000
30,100
22,000
43,300
31,300
59,000
41,700
73,900
53,200
88,000
66,000
COP
5.8
5.4
5.5
5.0
5.3
6.0
5.6
5.7
5.5
6.1
5.5
6.4
5.5
6.1
5.2
5.9
4.8
5.1
Cooling
EWT 59° F
Capacity
Btuh
20,600
21,900
31,200
36,800
43,900
50,300
66,900
75,000
27,700
22,200
40,000
29,900
54,100
41,600
69,000
53,000
79,000
61,500
EER
Btuh/W
26.0
27.5
29.5
28.8
28.1
25.9
24.3
22.9
24.0
29.7
24.4
32.1
24.5
33.0
23.9
30.7
22.0
27.6
Heating
EWT 50° F
Capacity
Btuh
18,700
19,500
26,000
29,200
36,100
44,700
59,200
68,000
23,900
17,500
35,000
24,900
47,200
33,600
60,400
43,500
71,000
52,700
COP
4.9
4.7
4.7
4.4
4.6
5.0
4.8
4.9
4.8
4.9
4.9
5.1
4.6
4.7
4.6
4.8
4.3
4.3
Ground Loop Heat Pump
Cooling Brine
Full Load 77° F
Part Load 68° F
Heating Brine
Full Load 32°F
Part Load 41°F
Capacity
Btuh
EER
Heating
Capacity
COP
18,500
19,200
28,100
33,700
40,700
45,900
62,200
69,100
26,400
21,000
38,200
29,500
50,800
39,800
65,500
50,500
73,800
59,400
19.6
19,500
26.0
16,400
19.7
28,500
28.0
22,900
19.3
38,200
27.4
31,000
19.3
47,300
26.5
38,200
18.2
55,400
24.9
47,400
18.3
14,500
18.7
15,000
22.0
20,500
22.0
24,400
21.7
28,900
18.8
36,400
18.4
47,900
17.6
54,000
4.0
4.0
4.0
3.7
3.8
4.0
3.9
4.2
4.0
4.5
4.2
4.8
4.0
4.4
3.8
4.3
3.7
3.9
7/15/2015
PSC Motors
AHRI/ASHRAE/ISO 13256-1
English (IP) Units
Water Loop Heat Pump
Model
Modulation
Capacity
Flow Rate
Cooling
EWT 86°F
Heating
EWT 68°F
gpm cfm
Capacity
Btuh
EER
Btuh/W
Capacity
Btuh
COP
036
042
048
060
070
012
018
022
030
Single
Single
Single
Single
Single
Single
Single
Single
Single
8
8
4
5
400
600
850
900
9
11
1200
1300
12 1500
15 1800
18 2000
11
17400
17200
26800
31500
38300
43200
61000
66200
4
14.8
13.6
17.9
14.8
15.4
13.3
15.2
14.4
480
23000
23500
32900
40200
45600
55600
74100
85000
Cooling capacities based upon 80.6°F DB, 66.2°F WB entering air temperature
Heating capacities based upon 68°F DB, 59°F WB entering air temperature
All ratings based upon 208V operation
5.1
5.9
5.3
5.3
5.2
4.9
5.2
4.6
Cooling
EWT 59°F
Capacity
Btuh
320
20600
20100
30800
35100
42300
48900
66600
73500
EER
Btuh/W
3.
24.7
25.5
27.1
24.4
23.3
22.3
22.8
20.8
Ground Water Heat Pump
Heating
EWT 50°F
Capacity
Btuh
COP
200
18700
19400
26000
29200
36000
44700
57300
67100
4.5
4.3
4.2
4.4
.
4.3
4.8
4.7
Ground Loop Heat Pump
Cooling Brine
Full Load 77°F
Part Load 68°F
Heating Brine
Full Load 32°F
Part Load 41°F
Capacity
Btuh
EER
Btuh/W
Capacity
Btuh
COP
2000
18500
17700
27900
32900
40300
45500
62300
6910
6.5
17.3
16.2
21.1
19.2
18.5
6
17.4
6.
9500
14500
15000
20300
24400
28900
640
46100
350
3.8
3.5
.7
3.7
.4
.5
3.5
3.8
3.7
7/15/2015
6
T1GX, T2GX SERIES SPECIFICATION CATALOG
AHRI/ISO 13256-1 Performance Ratings cont.
Energy Star Compliance Table
Model
042
048
049
060
064
070
072
012
018
022
026
030
036
038
E - Unit with ECM Blower
X - Unit with 5-Speed ECM Blower
P - Unit with PSC Blower
Ground Water
P
E, P
E, X, P
E, X
E, X, P
E, X, P
E, X
E, X, P
E, X, P
E, X
E, X, P
E, X
E, X
E, X
Tier 3
Ground Loop
-
E
E, X
E, X
E, X, P
E, X, P
E, X
E, X
E, X
E, X
E, X, P
E, X
E, X
E, X
12/14/16
Energy Star Rating Criteria
In order for water-source heat pumps to be Energy Star rated they must meet or exceed the minimum efficiency requirements listed below. Tier 3 represents the current minimum efficiency water source heat pumps must have in order to be
Energy Start rated.
Tier 3: 1/1/2012 – No Effective End Date Published
Water-to-Air
Ground Loop
Ground Water
EER COP
17.1
21.1
3.6
4.1
Water-to-Water
Ground Loop
Ground Water
16.1
20.1
3.1
3.5
7
T1GX, T2GX SERIES SPECIFICATION CATALOG
AHRI/ISO 13256-1 Performance Ratings cont.
The performance standard AHRI/ASHRAE/ISO 13256-1 became effective January 1, 2000 and replaces ARI Standards 320, 325, and 330.
This new standard has three major categories: Water Loop (comparable to ARI 320), Ground Water (ARI 325), and Ground Loop (ARI
330). Although these standards are similar there are some differences:
Unit of Measure: The Cooling COP
The cooling efficiency is measured in EER (US version measured in Btu/h per Watt. The Metric version is measured in a cooling COP
(Watt per Watt) similar to the traditional COP measurement.
Water Conditions Differences
Entering water temperatures have changed to reflect the centigrade temperature scale. For instance the water loop heating test is performed with 68°F (20°C) water rounded down from the old 70°F (21.1°C).
Air Conditions Differences
Entering air temperatures have also changed (rounded down) to reflect the centigrade temperature scale. For instance the cooling tests are performed with 80.6°F (27°C) dry bulb and 66.2°F (19°C) wet bulb entering air instead of the traditional 80°F (26.7°C) DB and
67°F (19.4°C) WB entering air temperatures. 80.6/66.2 data may be converted to 80/67 using the entering air correction table. This represents a significantly lower relative humidity than the old 80/67 of 50% and will result in lower latent capacities.
Pump Power Correction Calculation
Within each model, only one water flow rate is specified for all three groups and pumping Watts are calculated using the following formula. This additional power is added onto the existing power consumption.
• Pump power correction = (gpm x 0.0631) x (Press Drop x 2990) / 300
Where ‘gpm’ is waterflow in gpm and ‘Press Drop’ is the pressure drop through the unit heat exchanger at rated water flow in feet of head.
Blower Power Correction Calculation
Blower power is corrected to zero external static pressure using the following equation. The nominal airflow is rated at a specific external static pressure. This effectively reduces the power consumption of the unit and increases cooling capacity but decreases heating capacity. These Watts are significant enough in most cases to increase EER and COPs fairly dramatically over ARI
320, 325, and 330 ratings.
• Blower Power Correction = (cfm x 0.472) x (esp x 249) / 300
Where ‘cfm’ is airflow in cfm and ‘esp’ is the external static pressure at rated airflow in inches of water gauge.
ISO Capacity and Efficiency Calculations
The following equations illustrate cooling calculations:
• ISO Cooling Capacity = Cooling Capacity (Btu/h) + (Blower Power Correction (Watts) x 3.412)
• ISO EER Efficiency (W/W) = ISO Cooling Capacity (Btu/h) x 3.412 / [Power Input (Watts) - Blower Power Correction (Watts) + Pump
Power Correction (Watt)]
The following equations illustrate heating calculations:
• ISO Heating Capacity = Heating Capacity (Btu/h) - (Blower Power Correction (Watts) x 3.412)
• ISO COP Efficiency (W/W) = ISO Heating Capacity (Btu/h) x 3.412 / [Power Input (Watts) - Blower Power Correction (Watts) +
Pump Power Correction (Watt)]
Comparison of Test Conditions
ARI 320
ISO/AHRI
13256-1
WLHP
ARI 325
ISO/AHRI
13256-1
GWHP
ARI 330
Cooling
Entering Air - DB/WB °F
Entering Water - °F
Fluid Flow Rate
Heating
Entering Air - DB/WB °F
Entering Water - °F
Fluid Flow Rate
80/67
85
*
70
70
*
80.6/66.2
86
**
68
68
**
80/67
50/70
**
70
50/70
**
80.6/66.2
59
**
68
50
**
80/67
77
**
70
32
**
Conversions:
NOTES: * Flow rate is set by 10°F rise in standard cooling test
** Flow rate is specified by the manufacturer
Part load entering water conditions not shown
WLHP = Water Loop Heat Pump; GWHP = Ground Water Heat Pump; GLHP = Ground Loop Heat Pump
Airflow (lps) = cfm x 0.472;
ESP (Pascals) = ESP (in wg) x 249;
WaterFlow (lps) = gpm x 0.0631;
Press Drop (Pascals) = Press Drop (ft hd) x 2990
ISO/AHRI
13256-1 GLHP
80.6/66.2
77
**
68
32
**
8
T1GX, T2GX SERIES SPECIFICATION CATALOG
COMPRESSOR: Rotary (012-018), scroll (022-070 single speed) and dual capacity scroll represent the latest technology
DOUBLE ISOLATED COMPRESSOR: Double isolated compressor mounting to reduce noise and vibration
MICROPROCESSOR CONTROLS:
OPTIONAL HOT WATER ASSIST: Provides free hot water in cooling and very high efficiency hot water generation in heating mode
COAXIAL HEAT EXCHANGER: Standard large high efficiency copper (optional cupronickel) coax with our exclusive void-free and robotically applied ThermaShield insulation coating
BALANCED PORT/BIDIRECTIONAL EXPANSION VALVE:
Balanced port bidirectional expansion valve for rock steady superheat control and reliable efficiency and operation at any condition
AIR COIL: Large air coil is designed for maximum efficiency, provides moisture removal and superior protection from formicary corrosion
DISCHARGE MUFFLER: Helps quiet compressor gas pulsations
PSC/5-Speed/ECM BLOWER MOTOR OPTIONS: Choice of standard PSC, high efficiency 5-Speed ECM, or high efficiency and ultra-flexible ECM blower motors
FILTER RACK: Filter rack holds 1 in. or 2 in. filters (field changeable) with exclusive snap on filter door
FILTER: High holding capacity 2 in. pleated MERV 11 filter is standard and 4 in. pleated MERV 11 Is optional
SWIVEL LOOP CONNECTIONS: Leak free swivel water connections provide a hand tight gasket connection that easily handles the temperature extremes of geothermal earth loops
IntelliStart®: Optional single phase soft starter
INSULATION: Cleanable foil lined insulation to prevent mold growth; corrosion resistant composite drain pan
CABINET FINISH: Heavy gauge galvanized sheet metal cabinet has 1,000 hr. salt spray rated powder coat paint for long life
ACCESS PANELS: Lift out front bottom access panel, lift out panels for easier removal and servicing
LED STATUS LIGHTS: Mounted higher on the unit
COMPOSITE DRAIN PAN: Custom moulded and positively sloped for condensate drainage
9
T1GX, T2GX SERIES SPECIFICATION CATALOG
TGX Design Features cont.
What’s New?
• Exceptional AHRI/ISO 13256-1 Ratings for traditional geothermal
- 28 EER and 4.8 COP
• Latest technology compressors
- LG Rotary in single speed units (sizes 012 and 018)
- Scrolls in single speed units (sizes 022, 030, 036, 042,
048, 060, 070)
- Dual capacity scrolls in units (sizes 026, 038, 049, 064,
072)
• Discharge line mufflers on models 022-072 to help quiet compressor discharge gas pulsations.
• PSC/5-Speed ECM/ECM blower motor options
- Standard PSC for low cost and solid performance
- 5-Speed ECM for high efficiency
- ECM blower motors for the highest in efficiency and airflow flexibility
• Cabinet Design – Improved design of access panels, control box and filter rack
• Cabinet Configurations – Vertical left or right return, downflow left or right return; Horizontal left or right return with either end or side air discharge
• Cupronickel heat exchanger
• High static blower on some models
Operating Efficiencies
• AHRI/ISO 13256-1 rating for heating COPs, cooling EERs, and low water flow requirements
• Optional hot water generator with internal pump generates hot water at considerable savings while improving overall system efficiency
• High-stability expansion valve delivers optimum refrigerant flow over a wide range of conditions and provides bidirectional operation without troublesome check valves
• Efficient rotary and scroll compressors operate quietly
• Oversized coaxial tube water-to-refrigerant heat exchanger operates at low liquid pressure drops
• Convoluted copper water tube functions efficiently at low flow rates
• Oversized all-aluminum lanced fin refrigerant heat exchanger provides high efficiencies at low-face velocity
• Large, low-RPM blowers with ECM or 5-Speed ECM motors provide quiet and efficient air movement with high static capability; optional 3-Speed PSC motors available on single speed units
• Utilizes the ozone-friendly R-410A refrigerant which produces higher efficiencies and warmer discharge air temperatures
Application Flexibility
• Safe, efficient operation in a wide range of liquid temperatures
(20°F to 120°F) and flow rates (as low as 1.5 gpm/ton in open loop applications when EWT >50°F)
• Top or rear air discharge for upflow, or bottom discharge for counterflow installations in vertical units, side or end discharge for horizontal units
• True left or right return air locations—vertical units include filter rack/duct collar
• Variable-speed ECM blowers permit various duct applications with flexible airflow selection; optional 5-Speed ECM blower motors provide ECM efficiency at PSC capability; optional PSC motors available on single speed units.
• Narrow cabinet for easy movement through doorways
• Internally trapped condensate piping on vertical units for neat, compact installation
• Optional field-installed auxiliary electric heater
• Corner-located electrical box for field wiring from two sides
• Circuit breaker protected loop pump power block for easy wiring
• Relay to control field-mounted accessories
• Field-selectable freeze detection setting for well or closed loop systems
Service Advantages
• Removable panels: three for the compressor compartment and one (on horizontals) or two (on verticals) for the air handling compartment to provide quick access to all internal components with ductwork in place
• Easily accessible thermal expansion valve
• Brass, swivel-type water connections for quick connection union, and elimination of wrenches and sealants during installation; sweat type connections are on the hot water generator
• Insulated divider and separate air handling/compressor access panels permit service testing without air bypass
• Designed for front access in tight applications
• LED fault and status lights
• Hot water pump shut-off switch for easy startup and service
• Control box and blower motors have quick-attach wiring plugs for easy removal
• Internal drop-out blower with permanently-lubricated ball bearing motor
• High- and low-pressure service ports in refrigerant circuit.
• Blower and transformer powered from auxiliary heat supply
(when installed) to provide emergency heat with open compressor circuit breaker
10
T1GX, T2GX SERIES SPECIFICATION CATALOG
TGX Design Features cont.
Product Quality
• Heavy-gauge steel cabinets are painted with durable powder coat paint for long lasting beauty and service
• Coaxial heat exchanger, refrigerant suction lines, hot water generator coil, and all water pipes are fully insulated to reduce condensation problems in low temperature operation
• All aluminum air coils for superior protecion from formicary corrosion
• Noise reduction features include double isolation mounted compressors and soft starting blower motors; insulated compressor compartment; interior cabinet insulation using 1/2 in. coated glass fiber; all units include compressor blanket for quiet operation
• Safety features include high- and low-pressure refrigerant controls to protect the compressor, condensate overflow protection, freeze detection sensor to safeguard the coaxial heat exchanger, blower start detection, hot water high-limit hot water generator pump shutdown, compressor monitoring, and fault lockout enables emergency heat and prevents compressor operation until thermostat or circuit breaker is reset
Manufacturing Quality
• All units are computer run-tested, with conditioned source water, in all modes to ensure efficiency and reliability
• All refrigerant brazing is performed in a nitrogen atmosphere
• All units are deep evacuated to less than 150 microns prior to refrigerant charging
• All joints are helium leak-tested to ensure an annual leak rate of less than 1/4 ounce
• All major components bar coded; eliminating possibility of mismatched parts built into unit
• All assembly technicians thoroughly trained in proper quality procedures
• All units have model number and serial number embedded in control for local or remote retrieval
• Manufacturing facility is ISO 9001:2008 certified
• Engineering labs are ISO 17025 accredited
Microprocessor Benefits
• Digital auto-changeover thermostat with 3-stage heating/2-stage cooling holds precise temperature and provides varying blower speed control.
• Component sequencing delays for quiet startup, shutdown, and timed staging of auxiliary electric heat.
• ECM blower speed control provides higher supply air temperature in heating, better dehumidification in cooling, and quiet operation at reduced airflows in all modes.
• Hot water limit prevents scalding, and pump shuts down automatically when full unit capacity is needed for heating.
Options and Accessories
• Optional cupronickel heat exchangers for open loop applications
• Optional hot water generator with internally mounted pump and water heater plumbing connector
• Optional 3-speed PSC motors available on single speed units (4-speed on 012)
• Optional 5-Speed ECM motors available (022-072)
• Optional high static PSC blower motor for high static applications on single speed units (022-048)
• Optional high static ECM blower motor for high static applications on all units from 036 to 049
• Electronic auto-changeover thermostat with 3-stage heating/2stage cooling and indicator LEDs (non-communicating)
• 24 Volt 1 in. electronic air cleaner
• 90% efficient, cleanable electrostatic filters
• Closed loop flow center in several sizes
• Auxiliary electric heater
• Additional accessory relay
• AlpinePure 2 in. MERV 13 filter
• IntelliStart soft starter
11
T1GX, T2GX SERIES SPECIFICATION CATALOG
Startup
The unit will not operate until all the inputs and safety controls are checked for normal conditions. At fi rst power-up, a four minute delay is employed before the compressor is energized.
Component Sequencing Delays
Components are sequenced and delayed for optimum space conditioning performance.
Shutdown Mode
A 24VAC common signal to the “shutdown” input on the control board puts the unit into shutdown mode. Compressor, hot water pump and fan operation are suspended.
Safety Controls
The microprocessor control receives separate signals for a high pressure switch for safety, a low pressure switch to prevent loss of charge damage, and a low suction temperature thermistor for freeze sensing. Upon a continuous 30-second measurement of the fault (immediate for high pressure), compressor operation is suspended, the appropriate lockout LED begins fl ashing. (Refer to the "Fault Retry" section below.)
Testing
The microprocessor control allows service personnel to shorten most timing delays for faster diagnostics. (Refer to the Field
Selection DIP switch SW2-1 in the Microprocessor Control section.)
Diagnostics
The microprocessor control board allows all inputs and outputs to be displayed on the LEDs for fast and simple control board diagnosis. (Refer to the Field Selection DIP Switch SW2-1 in the
Microprocessor Control section.)
Resistance Heat Control (208-230 Units)
The electric heat control module contains the appropriate highvoltage control relays. Control signals energize the relays in the proper sequence, and the LED display board indicates which stages are energized.
Accessory Relay
An accessory relay on the control board allows for fi eld connection of solenoid valves, electronic air cleaners, etc.
The accessory relay has a normally open output and a normally closed output.
Short Cycle Protection
The control employs a minimum "off" time of four minutes to provide for short cycle protection of the compressor.
Condensate Overflow Protection
The microprocessor control board incorporates an impedance sensing liquid sensor at the top of the drain pan. Upon a continuous
30-second sensing of the condensate, compressor operation is suspended (see Fault Retry), and the condensate overfl ow lockout
LED begins fl ashing.
Hot Water High Limit
(Domestic Hot Water Option)
This mode occurs when the hot water input temperature is at or above 130°F for 30 continuous seconds. The HWG limit status
LED on the unit illuminates and the hot water pump de-energizes.
Hot water pump operations resume on the next compressor cycle or after 15 minutes of continuous compressor operation during the current thermostat demand cycle.
Hot Water Justification
Since compressor hot gas temperature is dependant on loop temperature in cooling mode, loop temperatures may be too low to allow proper heating of water. The control will monitor water and refrigerant temperatures to determine if conditions are satisfactory for heating water. The HWG limit status LED on the unit illuminates when conditions are not favorable for heating water.
Heating Operation
Heat, 1st Stage (Y1)
The fan motor is started on low speed immediately (PSC ON), the loop pump is energized 5 seconds after the “Y1” input is received, and the compressor is energized on low capacity 10 seconds after the “Y1” input. The fan is switched to medium speed 15 seconds after “Y1” input (ECM only). The hot water pump is cycled 30 seconds after the "Y1" input.
Heat, 2nd Stage (Y1,Y2) Single-Speed Units
The hot water pump is de-energized, which directs all heat to satisfying the thermostat, and the fan changes to high speed 15 seconds after the "Y2" input (ECM only).
Fault Retry
All faults (except for low RPM faults with the ECM fan motor) are retried twice before fi nally locking the unit out. An output signal is made available for a fault LED at the thermostat. The “fault retry” feature is designed to prevent nuisance service calls.
Heat, 2nd Stage (Y1,Y2) Dual Capacity Units
The second stage compressor will be activated 5 seconds after receiving a “Y2” input as long as the minimum fi rst stage compressor run time of 1 minute has expired. The ECM blower changes from medium to high speed 15 seconds after the “Y2” input.
12
T1GX, T2GX SERIES SPECIFICATION CATALOG
Heat, 3rd Stage (Y1,Y2,W) -
Single-Speed Units
The fi rst stage of resistance heat is energized 10 seconds after
“W” input, and with continuous 3rd stage demand, the second stage of resistance heat will engage after 5 minutes.
Heat, 3rd Stage (Y1,Y2,W) -
Dual Capacity Units
The hot water pump is de-energized which directs all heat to satisfy the thermostat. The 1st stage of resistance heat is energized 10 seconds after “W” input, and with continuous 3rd stage demand, the second stage of resistance heat will engage after 5 minutes.
Emergency Heat (W only)
The fan is started on high speed, and the fi rst stage of resistance heat is energized 10 seconds after the "W" input.
Continuing demand will engage the second stage of resistance heat after 2 minutes.
Cooling Operation
In all cooling operations, the reversing valve directly tracks the “O” input. Thus, anytime the “O” input is present, he reversing valve will be energized.
Cool, 1st Stage (Y1,O)
The blower motor and hot water pump are started immediately, the loop pump(s) is energized 5 seconds after the “Y1” input is received. The compressor will be energized (on low capacity for
Dual Capacity units) 10 seconds after the “Y1” input. The ECM blower will shift from low to medium speed 15 seconds after the
“Y1” input (85% of medium speed if in dehumidifi cation mode).
Cool, 2nd Stage (Y1, Y2, O) -
Single Speed Units
The fan changes to high speed (85% of high speed if in dehumidifi cation mode) 15 seconds after the “Y2” input (ECM only).
Cool, 2nd Stage (Y1, Y2, O) -
Dual Capacity Units
The second stage compressor will be activated 5 seconds after receiving a “Y2” input as long as the minimum fi rst stage compressor run time of 1 minute has expired. The ECM blower changes to high speed 15 seconds after the “Y2” input. (85% of high speed if in dehumidifi cation mode).
Fan (G only)
The fan starts on low speed. Regardless of fan input “G” from thermostat, the fan will remain on low speed for 30 seconds at the end of each heating, cooling or emergency heat cycle.
A DIP switch on the microprocessor control allows fi eld selection of
15% reduced fan speeds for cooling in the dehumidifi cation mode or medium and high fan speeds for cooling in the normal mode.
NOTE: Fan speed can change automatically only with a Variable
Speed ECM Motor.
Variable Speed ECM Airflow Selection DIP
Switches (SW1)
A 12-position DIP switch package on the microprocessor control allows the airfl ow levels to be set for low, medium and high speed.
(Refer to the Variable Speed ECM Blower table in the Fan
Performance Data - Variable Speed ECM section.)
Only three of the DIP switches can be in the “on” position. The fi rst “on” switch (the lowest position number) determines the
“low speed fan” setting. The second “on” switch determines the
“medium speed fan” setting, and the third “on” switch determines the “high speed fan” setting, (see the Fan Performance Data -
Variable Speed ECM section).
Lockout Conditions
During lockout mode, the appropriate unit and thermostat lockout
LEDs will illuminate. The compressor, loop pump, hot water pump, and accessory outputs are de-energized. Unless the lockout is caused by an ECM low RPM fault, the fan will continue to run on low speed. If the thermostat calls for heating, emergency heat operation will occur.
All lockout modes can be reset at the thermostat after turning the unit off, then on, which restores normal operation but keeps the unit lockout LED illuminated. Interruption of power to the unit will reset a lockout without a waiting period and clear all lockout LEDs.
High Pressure
This lockout mode occurs when the normally closed safety switch is opened momentarily (set at 600 PSI).
Low Pressure
This lockout mode occurs when the normally closed low pressure switch is opened for 30 continuous seconds (set at 40 PSI).
13
T1GX, T2GX SERIES SPECIFICATION CATALOG
Microprocessor Control System cont.
Freeze Sensing (Water Flow)
This lockout mode occurs when the freeze thermistor temperature is at or below the selected freeze sensing point (well
30°F or loop 15°F) for 30 continuous seconds.
Condensate Overflow
This lockout mode occurs when the condensate overfl ow level has been reached for 30 continuous seconds.
Fan RPM
The control board monitors fan RPM to sense operation. This lockout mode occurs if the fan RPM falls below the low RPM limit
(100 RPM) for 30 continuous seconds.
14
T1GX, T2GX SERIES SPECIFICATION CATALOG
Microprocessor Control System cont.
DIP Switch Settings
Prior to powering unit, ensure that all DIP switches on SW2 & SW3 are set properly according to the tables below.
FACTORY SETUP DIP SWITCHES (SW3)
DIP
SWITCH
NUMBER
DESCRIPTION OFF POSITION
SW 31
Dual Capacity/Single-Speed
Confi gures the control for single-speed compressor operation or dual capacity operation.
Dual Capacity
Operation
SW 32
Zoned/Finish on Second Stage
This switch allows the unit to down stage with the thermostat when off and fi nish with second stage when on. Finish on second stage reduces stage changing in reciprocating dual capacity compressors.
Normal - All Other
Systems
SW 33
SW 34
SW 35
No RPM/RPM
Confi gures the control to monitor the RPM output of an ECM blower motor. When using
IntelliZone or a PSC fan motor, the control should be confi gured for “NO RPM” sensing.
Electric heat and ECM
Allows backward compatibility with older models. In the Off position this switch allows older electric heat board (17P501A01) and older ECM (square end) compatibility. On is for all newer EH board (17P514A01) and ECM (round end).
On dual capacity units this switch allows stage change: on the fl y when off, and 1 minute delay when on. A delay is required on all reciprocating dual capacity units.
FIELD SELECTION DIP SWITCHES (SW2)
DIP
SWITCH
NUMBER
DESCRIPTION
SW 21
Service Test Mode
On the control, allows fi eld selection of “NORMAL” or “TEST” operational modes. Test mode accelerates most timing functions 16 times to allow faster troubleshooting. Test mode also allows viewing the “CURRENT” status of the fault inputs on the LED display.
PSC Fan/RPM
Monitoring Disabled
Old EH & Old ECM
2GX Series
OFF POSITION
Test Mode
ON POSITION
Single-Speed Operation
Finish on 2nd -
Unzoned Dual Capacity
ECM Fan/RPM Monitoring
Enabled
Normal
N/A
ON POSITION
Normal Speed Operation
SW 22
Freeze Sensing Setting
Allows fi eld selection of freeze thermistor fault sensing temperatures for well water (30°F) or antifreeze-protected (15°F) earth loops.
Loop Water Freeze
Protection 15° F
SW 23
Accessory Relay
Allows fi eld selection of the accessory relay to operate with the compressor or fan.
Acc Relay Tracks Fan
SW 24
Fan Speed Control
Allows fi eld selection of reduced fan speed (85% of selected medium and high speed – ECM only) for cooling in the dehumidifi cation mode.
Dehumidifi cation Fan
Speeds
Well Water Freeze
Protection 30° F
Acc Relay Tracks
Compressor
Normal Fan Speeds
SW 25
Auxiliary Off
Disables 3rd-stage Heating. Full emergency heat would still be available if needed.
SW 26
SW 2-
SW 2-
7
8
Diagnostics Inputs
Allows viewing the inputs from the thermostat to the control board such as Y1, Y2, O, G, W,
SL1-In on the LED display.
Diagnostics Outputs
Allows viewing the outputs from the control board such as compressor, reversing valve, blower, hot water pump, and loop pump on the LED display.
Thermostat Selection
Confi gures the control for a pulsed lockout signal (FaultFlash thermostats) or continuous 5
VAC lockout signal.
Disable Heating
Stage 3
Diagnostic Inputs
Viewed at LEDs
Diagnostic Outputs
Viewed at LEDs
Pulsed “L” signal
Enable Heating
Stage 3
Normal Display Viewed at
LEDs
Normal Display Viewed at
LEDs
Continuous “L” signal
15
T1GX, T2GX SERIES SPECIFICATION CATALOG
Operation Logic Data Table
STG1
HEATING
STG2 STG3
OPERATION LOGIC
SINGLE SPEED UNITS
Compressor
ECM Normal
ECM Dehumidify
Rev Valve
Loop Pump
HWG Pump
Aux Heater
Secondary 1- Out
Emerg LED
T-Stat Signal
DUAL CAPACITY UNITS
Compressor-Lo
Compressor-Hi
ECM Normal
ECM Dehumidify
Rev Valve
Loop Pumps
HWG Pump
Aux Heater
Secondary 1- Out
Secondary 2- Out
Emerg LED
T-Stat Signal
On
On
Off
On
Off
Y1
On
Med
Med
Off
On
Off
On
Off
On
Off
Med
Med
Off
On
Off
Y1
EMERG
COOLING
STG1 STG2
On
High
High
Off
On
Off
Off
On
Off
Y1, Y2
On
High
High
Off
On
Off
Staged
On
Off
Y1, Y2, W
Off
High
High
Off
Off
Off
Staged
Off
On
W
On
Med
On
High
85% Med 85% High
On On
On
On
Off
On
Off
Y1, O
On
On
Off
On
Off
Y1, Y2, O
Off
On
High
High
Off
On
On
Off
On
On
Off
Y1, Y2
Off
On
High
High
Off
On
Off
Staged
On
On
Off
Y1, Y2, W
Off
Off
High
High
Off
Off
Off
Staged
Off
Off
On
W
On
Off
Off
On
Med High
85% Med 85% High
On
On
On
On
On
Off
On
Off
Off
Y1, O
On
Off
On
On
Off
Y1, Y2, O
FAN ON
-
-
-
-
-
-
Low
Low
-
-
-
G
-
Off
G
-
-
-
-
Low
Low
-
SL1 -
IN ON
-
-
-
-
-
-
-
-
-
On
-
-
-
-
-
On
-
-
-
-
-
-
16
T1GX, T2GX SERIES SPECIFICATION CATALOG
Water Quality
It is the responsibility of the system designer and installing contractor to ensure that acceptable water quality is present and that all applicable codes have been met in these installations.
Failure to adhere to the guidelines in the water quality table could result in loss of warranty. In ground water situations where scaling could be heavy or where biological growth such as iron bacteria will be present, a closed loop system is recommended. The heat exchanger coils in ground water systems may, over a period of time, lose heat exchange capabilities due to a buildup of mineral deposits inside. These can be cleaned, but only by a qualified service mechanic, as special solutions and pumping equipment are required. Hot water generator coils can likewise become scaled and possibly plugged. In areas with extremely hard water, the owner should be informed that the heat exchanger may require occasional flushing.
Heat pumps with cupronickel heat exchangers are recommended for open loop applications due to the increased resistance to build-up and corrosion, along with reduced wear caused by acid cleaning.
Water Treatment
Do not use untreated or improperly treated water. Equipment damage may occur. The use of improperly treated or untreated water in this equipment may result in scaling, erosion, corrosion, algae or slime. Purchase of a pre-mix antifreeze could significantly improve system reliability if the water quality is controlled and there are additives in the mixture to inhibit corrosion. There are many examples of such fluids on the market today such as
Environol™ 1000 (pre-mix ethanol), and others. The services of a qualified water treatment specialist should be engaged to determine what treatment, if any, is required. The product warranty specifically excludes liability for corrosion, erosion or deterioration of equipment.
The heat exchangers and water lines in the units are copper or cupronickel tube. There may be other materials in the buildings piping system that the designer may need to take into consideration when deciding the parameters of the water quality. If antifreeze or water treatment solution is to be used, the designer should confirm it does not have a detrimental effect on the materials in the system.
Contaminated Water
In applications where the water quality cannot be held to prescribed limits, the use of a secondary or intermediate heat exchanger is recommended to separate the unit fro P the contaminated water.
The table EHORZ outlines the water quality guidelines for unit heat exchangers. If these conditions are exceeded, a secondary heat exchanger is required. Failure to supply a secondary heat exchanger where needed will result in a warranty exclusion for primary heat exchanger corrosion or failure.
Material pH
Scaling
Corrosion
Iron Fouling
(Biological Growth)
Acidity/Alkalinity
Calcium and
Magnesium Carbonate
Hydrogen Sulfide
Sulfates
Chlorine
Chlorides
Carbon Dioxide
Ammonia
Ammonia Chloride
Ammonia Nitrate
Ammonia Hydroxide
Ammonia Sulfate
Total Dissolved Solids (TDS)
LSI Index
Iron, FE 2 + (Ferrous)
Bacterial Iron Potential
Iron Oxide
Suspended Solids
Erosion
Threshold Velocity
(Fresh Water)
NOTES: Grains = ppm divided by 17 mg/L is equivalent to ppm
Copper
7 - 9
(Total Hardness) less than 350 ppm
Less than 0.5 ppm (rotten egg smell appears at 0.5 ppm)
Less than 125 ppm
Less than 0.5 ppm
Less than 20 ppm
Less than 50 ppm
Less than 2 ppm
Less than 0.5 ppm
Less than 0.5 ppm
Less than 0.5 ppm
Less than 0.5 ppm
Less than 1000 ppm
+0.5 to -0.5
< 0 .
2 p p m
90/10 Cupronickel
7 - 9
(Total Hardness) less than 350 ppm
10 - 50 ppm
Less than 125 ppm
Less than 0.5 ppm
Less than 125 ppm
10 - 50 ppm
Less than 2 ppm
Less than 0.5 ppm
Less than 0.5 ppm
Less than 0.5 ppm
Less than 0.5 ppm
1000 - 1500 ppm
+0.5 to -0.5
< 0 .
2 p p m
316 Stainless Steel
7 - 9
(Total Hardness) less than 350 ppm
Less than 1 ppm
Less than 200 ppm
Less than 0.5 ppm
Less than 300 ppm
10 - 50 ppm
Less than 20 ppm
Less than 0.5 ppm
Less than 0.5 ppm
Less than 0.5 ppm
Less than 0.5 ppm
1000 - 1500 ppm
+0.5 to -0.5
< 0 .
2 p p m
Less than 1 ppm, above this level deposition will occur
Less than 10 ppm and filtered for max. of 600 micron size
Less than 1 ppm, above this level deposition will occur
Less than 10 ppm and filtered for max. of 600 micron size
Less than 1 ppm, above this level deposition will occur
Less than 10 ppm and filtered for max. of 600 micron size
< 6 f t / s e c < 6 f t / s e c < 6 f t / s e c
2/22/12
17
T1GX, T2GX SERIES SPECIFICATION CATALOG
Vertical Dimensional Data
Top Air Discharge
LEFT RETURN
Q
L O M
R N
L
P
RIGHT RETURN
O Q
N R
TOP TOP
1.9in
[4.8cm]
T T
1.9in
[4.8cm]
S S
C C
K J I
A
FRONT
D E H F G
2ft [61cm]
Primary Service Access
B
LEFT SIDE
B
RIGHT SIDE
012
Overall Cabinet Water Connections
Vertical
Top Flow
Model
A B C
Width Depth Height
D
Loop
In
E
Loop
Out
F
HWG
In
G
HWG
Out
H Loop
Cond- ensate
Water
FPT in.
22.2
cm. 56.4
22.5
57.2
34.5
87.6
2.3
5.9
5.3
11.9
14.9
8.6
1 in.
13.5
30.2
37.8
21.8
Swivel
HWG
Sweat
(I.D.)
1/2 in.
Female
Electrical
Connections
I
3/4 in. cond
J
1/2 in. cond
K
1/2 in. cond
Power
Supply
6.9
Ext
Pump
9.4
Low
Voltage
11.7
Discharge Connection duct flange installed (±0.10 in)
L
6.1
M N
Supply
Width
O
Supply
Depth
P
3.7
10.0
10.0
0.7
17.5
23.9
29.7
15.5
9.4
25.4
25.4
1.8
using std deluxe filter rack
Q
Return Connection
2.4
6.1
(±0.10 in)
R
Return
Depth
18.1
46.0
S
Return
Height
14.2
36.1
T
1.7
4.3
018
022-
030
036-
038
042-
049
060-
072 in.
cm. 57.2
in.
cm. 57.2
in.
cm. 65.0
in.
in.
22.5
22.5
25.6
25.6
cm. 65.0
25.6
cm. 65.0
26.5
67.3 100.1
26.5
67.3 123.2
31.6
80.3 128.0
31.6
31.6
39.4
48.5
50.4
54.4
80.3 138.2
58.4
80.3 148.3
2.3
5.8
2.0
5.1
2.3
5.8
2.3
5.8
2.3
5.8
5.3
13.4
16.4
9.6
1 in.
13.5
17.8
18.5
34.0
34.3
40.4
41.7
41.9
48.0
24.4
25.9
26.9
Swivel
7.0
13.5
16.5
10.2
1 in.
Swivel
7.3
15.9
18.9
10.6
1 in.
Swivel
7.3
15.9
18.9
10.6
1 in.
18.5
40.4
48.0
26.9
Swivel
7.3
15.9
18.9
10.6
1 in.
18.5
40.4
48.0
26.9
Swivel
1/2 in.
Female
1/2 in.
Female
1/2 in.
Female
1/2 in.
Female
1/2 in.
Female
6.9
9.5
9.5
9.4
12.1
12.1
11.7
14.3
14.3
6.3
6.9
6.9
0.7
1.1
1.1
14.0
18.0
18.0
14.0
18.0
18.0
Condensate is 3/4 in. PVC female glue socket and is switchable from side to front
Unit shipped with deluxe 2 in. (field adjustable to 1 in.) duct collar/filter rack extending from unit 3.25 in. and is suitable for duct connection.
Discharge flange is field installed and extends 1 in. [25.4 mm] from cabinet
Decorative molding and/or water connections extend 1.2 in. [30.5 mm] beyond front of cabinet.
Top auxiliary electric heat power knockouts are 1.125" and 1.375".
2.7
17.5
23.9
29.7
16.0
1.8
35.6
35.6
6.9
9.5
12.1
14.3
6.1
0.8
14.0
14.0
4.4
2.3
5.8
1.7
24.1
30.7
36.3
15.5
2.0
35.6
35.6
11.2
4.3
56.4
66.0
4.3
9.5
12.1
14.3
6.9
1.1
18.0
18.0
3.8
24.1
30.7
36.3
17.5
2.8
45.7
45.7
9.7
3.8
24.1
30.7
36.3
17.5
2.8
45.7
45.7
9.7
3.8
24.1
30.7
36.3
17.5
2.8
45.7
45.7
9.7
1.7
4.3
1.7
4.3
1.7
4.3
22.0
55.9
22.2
28.1
71.4
28.1
71.4
28.1
71.4
18.0
45.7
26.0
26.0
66.0
30.0
76.2
34.0
86.4
2.0
5.1
1.7
1.7
4.3
1.7
4.3
1.7
4.3
7/11/12
18
T1GX, T2GX SERIES SPECIFICATION CATALOG
Vertical Dimensional Data cont.
Bottom Air Discharge
LEFT RETURN RIGHT RETURN
C
S S
C
T T
B
LEFT SIDE
R
2ft [61cm]
Primary Service Access
L
O
M N
LEFT BOTTOM DISCHARGE
FLOOR FOOT PRINT
Q
O
B
RIGHT SIDE
R
N L
RIGHT BOTTOM DISCHARGE
FLOOR FOOT PRINT
Q
P
K
J
I
1.90
(4.7 cm)
5
A
FRONT
4
3
2
1
1.70
(4.3 cm)
D
E
F
G
H
Bottom
Flow
Models
022-
030
Overall Cabinet
A B C
Width Depth Height
1
D
In
2
E
Out
Water Connections
3
F
HWG
In
4 5
G
HWG
Out
H Loop
ConWater densate FPT in.
22.5
26.5
52.5
35.3
40.2
46.7
49.7
3.6
1 in. cm. 57.2
67.3
133.4
89.7
102.1 118.6 126.2
9.1
Swivel
1/2 in.
Female
41.9
Electrical
Knockouts
I
3/4 in. cond
HWG
Sweat
Power
(I.D.)
Supply
J
1/2 in. cond
Ext
Pump
43.6
K
1/2 in. cond
Low
Voltage
45.1
L
8.6
Discharge Connection duct flange installed (±0.10 in)
M
6.0
N
Supply
Width
O
Supply
Depth
P
9.3
10.5
1.0
106.4 110.7 114.6
21.8
15.2
23.6
26.7
2.5
036-
072 in.
25.5
31.5
62.5
43.4
48.4
57.0
60.0
3.6
1 in. cm. 64.8
80.0
158.8 110.2 122.9 144.8 152.4
9.1
Swivel
1/2 in.
Female
48.9
50.8
52.2
124.2 129.0 132.6
9.1
23.1
4.8
12.2
13.4
34.0
13.6
34.5
1.5
3.8
Condensate is 3/4 in. PVC female glue socket and is switchable from side to front
Vertical bottom flow unit shipped with deluxe 2 in. (field adjustable to 1 in.) duct collar/filter rack extending from unit 3.25 in. and is suitable for duct connection.
Decorative molding and/or water connections extend 1.2 in. (30.5mm) beyond front of cabinet.
Top auxiliary electric heat power knockouts are 1.125" and 1.375".
Return Connection using std deluxe filter rack
(±0.10 in)
Q R S
Return Return
Depth Height
T
2.2
22.2
26.0
5.6
5.6
56.4
66.0
14.2
1.8
28.1
34.0
5.6
4.6
71.4
86.4
14.2
7/11/12
19
T1GX, T2GX SERIES SPECIFICATION CATALOG
Vertical Dimensional Data cont.
Rear Air Discharge
M
C
N
L
O Q
1.90
1.90
K J
I
R
A
FRONT
D
E
H
F
G
T T
C
S S
R
C
Q P
M
L
N
C
A
REAR VIEW
LEFT RETURN
B
SIDE VIEW
LEFT RETURN
B
SIDE VIEW
RIGHT RETURN
A
REAR VIEW
RIGHT RETURN
042-
049
060-
072
Overall Cabinet Water Connections
Vertical
Rear
Discharge
Models
A B C
Width Depth Height
D E
Loop
In
Loop
Out
F
HWG
In
G
HWG
Out
H Loop
Water
Cond-
FPT ensate in.
25.6
31.6
54.4
2.3
7.3
15.9
18.9
10.6
cm. 65.0
80.3 138.2
5.8
18.5
40.4
48.0
26.9
in.
25.6
31.6
58.4
2.3
7.3
15.9
18.9
10.6
cm. 65.0
80.3 148.3
5.8
18.5
40.4
48.0
26.9
1”
Swivel
1”
Swivel
Electrical
Connections
Discharge Connection duct flange installed (±0.10 in)
HWG
Sweat
(I.D.)
I
3/4 in. cond
J
1/2 in. cond
K
1/2 in. cond
Power
Supply
Ext
Pump
Low
Voltage
L M
Supply Supply
Width Depth
N O P
1/2” female
Q
Return Connection using std deluxe filter rack
(±0.10 in)
R S
Return Return
Depth Height
T
9.5
12.1
14.3
13.3
13.6
39.4
9.1
8.1
1.7
28.1
30.0
1.7
24.1
30.7
36.3
33.8
34.5 100.1 23.1
20.6
4.3
71.4
76.2
4.3
1/2” female
9.5
12.1
14.3
13.3
13.6
43.4
9.1
8.1
1.7
28.1
34.0
1.7
24.1
30.7
36.3
33.8
34.5
110.2
23.1
20.6
4.3
71.4
86.4
4.3
Condensate is 3/4 in. PVC female glue socket and is switchable from side to front
Unit shipped with deluxe 2 in. (field adjustable to 1 in.) duct collar/filter rack extending from unit 3.25 in. and is suitable for duct connection.
Discharge flange is field installed and extends 1 in. [25.4mm] from cabinet
Decorative molding and/or water connections extend 1.2 in. [30.5mm] beyond front of cabinet.
Top auxiliary electric heat power knockouts are 1.125" and 1.375".
7/11/12
20
Horizontal Dimensional Data
T1GX, T2GX SERIES SPECIFICATION CATALOG
TOP VIEW
Q
P
2.1in [5.4cm]
MOUNT (2) HANGER BRACKETS
AS SHOWN TO ALLOW ACCESS
TO FILTER
1.9in
[4.8cm]
2ft [61cm]
Primary Service Access
FRONT VIEW
A
S
SIDE DISHCARGE VIEW
B
N O
L
M
C
L
END VIEW
O S
R
K J I D E F G
AS SHOWN LR UNIT (RR UNIT ON OPPOSITE SIDE—SAME DIMENSIONS)
H
Overall Cabinet Water Connections
Electrical
Connections
I
3/4 in.
J
1/2 in. cond cond
K
1/2 in. cond
Discharge Connection duct flange installed (±0.10 in)
Return Connection using std deluxe filter rack
(±0.10 in)
Horizontal
Model
A B C
Width Depth Height
D
In
E F G H
Out
HWG
In
HWG
Out
Cond- ensate
5.3
11.9
14.9
8.0
Loop
Water
FPT
HWG
Sweat
(I.D.)
L
Power
Supply
6.9
Ext
Pump
Low
Voltage
9.5
11.7
4.1
9.5
12.1
14.3
SEE
24.1
30.7
36.3
CHART
9.5
12.1
14.3
SEE
24.1
30.7
36.3
CHART
M N
Supply
Height
Supply
Depth
7.3
9.7
O
13.6
13.2
SEE
34.5
33.5
CHART
13.6
13.2
SEE
34.5
33.5
CHART
P Q R S
Return Return
Depth Height
1.7
17.8
14.6
1.4
012
018
022-
030
036-
038
042-
049
060-
072 in.
22.5
44.0
17.3
2.3
cm.
57.2
111.8
43.9
5.8
13.5
30.2
37.8
20.3
in.
22.5
53.0
19.3
2.3
5.3
13.8
16.8
8.0
cm.
57.2
134.6
49.0
5.8
13.5
35.1
42.7
20.3
in.
22.5
63.0
19.3
2.0
7.0
13.5
16.5
0.8
cm.
57.2
160.0
49.0
5.1
17.8
34.3
41.9
2.0
in.
25.6
72.0
21.3
2.3
7.3
15.9
18.9
0.8
cm.
65.0
182.9
54.1
5.8
18.5
40.4
48.0
2.0
in.
25.6
77.0
21.3
2.3
7.3
15.9
18.9
0.8
cm.
65.0
195.6
54.1
5.8
18.5
40.4
48.0
2.0
in.
25.6
82.0
21.3
2.3
7.3
15.9
18.9
0.8
cm.
65.0
208.3
54.1
5.8
18.5
40.4
48.0
2.0
1 in.
Swivel
1 in.
Swivel
1 in.
Swivel
1 in.
Swivel
1 in.
Swivel
1 in.
Swivel
1/2 in.
Female
1/2 in.
Female
1/2 in.
Female
1/2 in.
Female
1/2 in.
Female
1/2 in.
Female
17.5
6.9
17.5
9.5
24.1
9.5
24.1
24.1
9.5
24.1
12.1
30.7
12.1
30.7
29.7
11.7
29.7
14.3
36.3
14.3
36.3
10.4
1.8
4.6
2.3
5.8
SEE
CHART
18.5
10.5
26.7
10.5
26.7
13.6
34.5
24.6
9.5
24.1
9.4
23.9
13.2
33.5
5.8
14.7
8.2
20.8
5.8
14.7
SEE
CHART
Condensate is 3/4 in. PVC female glue socket and is switchable from side to front
Unit shipped with deluxe 2 in. (field adjustable to 1 in.) duct collar/filter rack extending from unit 3.25 in. and is suitable for duct connection.
Discharge flange is field installed and extends 1 in. [25.4mm] from cabinet
Decorative molding and/or water connections extend 1.2 in. [30.5mm] beyond front of cabinet.
4.3
2.2
5.6
2.8
7.1
45.2
21.8
55.4
30.5
77.5
37.1
16.5
41.9
16.9
42.9
3.6
1.5
3.8
1.3
3.3
2.8
35.5
18.9
1.3
7.1
2.8
7.1
2.8
7.1
90.2
40.4
102.6
45.4
115.3
48.0
18.9
48.0
18.9
48.0
3.3
1.3
3.3
1.3
3.3
7/11/12
Units Not Shown Above
Right Return End Discharge
Right Return Side Discharge
Left Return End Discharge
Left Return Side Discharge in cm in cm in cm in cm
L
2.8
7.1
4.9
12.4
4.9
12.4
2.8
7.1
O
4.6
11.8
6.9
17.5
7.6
19.4
6.9
17.5
21
T1GX, T2GX SERIES SPECIFICATION CATALOG
Physical Data
Single Speed
Model
C o m p r e s s o r ( 1 e a c h )
Factory Charge R410a, oz [kg]
(Aluminum tube and fin air coil)
Factory Charge R410a, oz [kg]
(Aluminum tube and fin air coil)
Blower Motor & Blower
Vertical
Horizontal
012
R
36 [1.02]
36 [1.02] o t a r y
018
42 [1.19]
48 [1.36]
022
56 [1.58]
54 [1.53]
030
64 [1.81]
64 [1.81]
SINGLE SPEED
036
82 [2.32]
76 [2.15]
042
S c r o ll
84 [2.38]
84 [2.38]
048
92 [2.60]
92 [2.60]
060
112 [3.17]
88 [2.49]
070
134 [3.79]
110 [3.11]
Blower Motor Type/Speeds
Blower Motor- hp [W]
High Static Blower Motor - hp [W]
Blower Wheel Size
(Dia x W), in. [mm]
High Static Blower Wheel Size
(Dia x W), in. [mm]
Coax and Water Piping
Water Connections Size - Swivel - in [mm]
HWG Connection Size - Female Sweat I.D.
- in [mm]
Coax & Piping Water Volume - gal [l]
Vertical
V S E C M
5-Spd ECM
PSC
VS ECM
5-Spd ECM
PSC
VS ECM
PSC
VS ECM &
5-Spd ECM
PSC
VS ECM
PSC n / a n/a
PSC -
4 Speeds n/a n/a
1/10 [75] n/a n/a n/a n/a
V a r i a b l e S p e e d E C M
5 Speed ECM
PSC - 3 Speeds
1/2 [373] n/a
1/6 [134] n/a n/a
1/2 [373]
1/2 [373]
1/5 [149] n/a
1/ [249]
1/2 [373]
1/2 [373]
1/3 [249] n/a
1/3 [249]
1/2 [373]
1/2 [373]
1/2 [373]
1 [746]
1/2 [373]
1/2 [373]
1 [746]
1/2 [373]
1 [746]
3/4 [560]
1/2 [373]
1 [746]
1/2 [373]
1 [746]
3/4 [560]
1 [746]
1 [746]
1 [746] n/a n/a
1 [746]
1 [746]
1 [746] n/a n/a
9 x 7
[229 x 178]
9 x 7
[229 x 178]
9 x 7
[229 x 178]
11 x 10
[279 x 254]
11 x 10
[279 x 254]
11 x 10
[279 x 254]
11 x 10
[279 x 254]
11 x 10
[279 x 254]
6 x 8
[152 x 203]
9 x 7
[229 x 178]
9 x 7
[229 x 178]
9 x 7
[229 x 178]
10 x 10
[254 x 254]
10 x 10
[254 x 254]
10 x 10
[254 x 254]
11 x 10
[279 x 254]
11 x 10
[279 x 254] n/a n/a n/a n/a n/a
9 x 7
[229 x 178] n/a
9 x 7
[229 x 178]
11 x 10
[279 x 254]
10 x 10
[254 x 254]
11 x 10
[279 x 254]
11 x 10
[279 x 254]
10 x 10
[254 x 254]
10 x 10
[254 x 254] n/a n/a n/a n/a
1” [25.4] n/a
0.35 [1.3]
1” [25.4]
1/2” [12.7]
0.40 [1.5]
1” [25.4]
1/2” [12.7]
0.7 [2.6]
1” [25.4]
1/2” [12.7]
1.0 [3.8]
1” [25.4]
1/2” [12.7]
1.3 [4.9]
1” [25.4]
1/2” [12.7]
1.3 [4.9]
1” [25.4]
1/2” [12.7]
1.6 [6.1]
1” [25.4]
1/2” [12.7]
1.6 [6.1]
1” [25.4]
1/2” [12.7]
2.3 [8.7]
Air Coil Dimensions (H x W), in. [mm]
Air Coil Total Face Area, ft2 [m2]
Air Coil Tube Size, in [mm]
Air Coil Number of rows
Filter Standard - 2” [51mm]
Pleated MERV11 Throwaway, in [mm]
Weight - Operating, lb [kg]
Weight - Packaged, lb [kg]
Horizontal
16 x 16
[406 x 406]
19 x 20
[483 x 508]
24 x 20
[610 x 542]
28 x 20
[711 x 542]
28 x 25
[711 x 635]
32 x 25
[813 x 635]
32 x 25
[813 x 635]
36 x 25
[914 x 635]
36 x 25
[914 x 635]
1.8 [0.167] 2.6 [0.242] 3.3 [0.310] 3.9 [0.362] 4.9 [0.451] 5.6 [0.570] 5.6 [0.570] 6.3 [0.641] 6.3 [0.641]
3/8 [9.5] 5/16 [7.9] 3/8 [9.5] 3/8 [9.5] 3/8 [9.5] 3/8 [9.5] 3/8 [9.5] 3/8 [9.5] 3/8 [9.5]
3
16 x 20
[406 x 508]
3
20 x 24
[508 x 610]
3
28 x 24
[712 x 610]
3
28 x 24
[712 x 610]
3
28 x 30
[712 x 762]
3
32 x 30
[813 x 762]
3
32 x 30
[813 x 762]
4
36 x 30
[914 x 762]
4
36 x 30
[914 x 762]
165 [75]
185 [84]
200 [91]
220 [100]
293 [133]
313 [142]
308 [140]
328 [149]
353 [160]
373 [169]
368 [167]
388 [176]
408 [185]
428 [194]
443 [201]
463 [210]
468 [212]
488 [221]
Air Coil Dimensions (H x W), in. [mm]
Air Coil Total Face Area, ft2 [m2]
Air Coil Tube Size, in [mm]
Air Coil Number of rows
Filter Standard - 2” [51mm] Pleated MERV11
Throwaway, in [mm]
Weight - Operating, lb [kg]
Weight - Packaged, lb [kg]
16 x 16 18 x 21 18 x 27 18 x 30 20 x 35 20 x 40 20 x 40 20 x 45 20 x 45
[406 x 406] [457 x 533] [457 x 686] [457 x 762] [508 x 889] [508 x 1016] [508 x 1016] [508 x 1143] [508 x 1143]
1.8 [0.167] 2.6 [0.242] 3.4 [0.316] 3.9 [0.362] 4.9 [0.451] 5.6 [0.570] 5.6 [0.570] 6.3 [0.641] 6.3 [0.641]
3/8 [9.5]
3
5/16 [7.9]
3
3/8 [9.5]
3
3/8 [9.5]
3
3/8 [9.5]
3
3/8 [9.5]
3
3/8 [9.5]
3
3/8 [9.5]
3
3/8 [9.5]
3
1 - 16 x 20
[406 x 508]
165 [75]
185 [84]
1 - 18 x 24
[457 x 610]
200 [91]
220 [100]
1 - 18 x 32 1 - 18 x 32
[457 x 813]
300 [136]
320 [145]
[457 x 813]
315 [143]
335 [152]
1 - 20 x 37
[686 x 940]
368 [167]
388 [176]
1 - 20 x 20
[508 x 508]
1 - 20 x 22
1 - 20 x 20
[508 x 508]
1 - 20 x 22
1 - 20 x 25
[508 x 635]
1 - 20 x 22
1 - 20 x 25
[508 x 635]
1 - 20 x 22
[508 x 559] [508 x 559] [508 x 559] [508 x 559]
403 [183]
423 [192]
418 [190]
438 [199]
453 [205]
473 [215]
478 [217]
498 [226]
7/15/15
22
T1GX, T2GX SERIES SPECIFICATION CATALOG
Physical Data cont.
Dual Capacity
Model
Compressor (1 each)
Factory Charge R410a, oz [kg] (Aluminum tube and fin air coil)
Factory Charge R410a, oz [kg] (Aluminum tube and fin air coil)
ECM Blower Motor & Blower
Blower Motor Type/Speeds
Blower Motor- hp [W]
H i g h S t a t i c B l o w e r M o t o r h p [ W ]
Blower Wheel Size (Dia x W), in. [mm]
H i g h S t a t i c B l o w e r W h e
Coax and Water Piping
A i r C o li T o t a l F a c e A r e a , f t 2 [ m 2 ]
Air Coil Tube Size, in [mm]
Air Coil Number of rows
Filter Standard - 2” [51mm] Pleated MERV11 Throwaway, in [mm]
Weight - Operating, lb [kg]
Weight - Packaged, lb [kg]
Horizontal
Air Coil Dimensions (H x W), in. [mm]
A i r C o li T o t a l F a c e A r e a , f t 2 [ m 2 ]
Air Coil Tube Size, in [mm]
Air Coil Number of rows e l S i z e [ D i a .
x W ] , i n .
[ m m ]
W a t e r C o n n e c t i o n s S i z e S w i v e l i n [ m m ]
H W G C o n n e c t i o n S i z e F e m a l e S w e a t I .
D .
i n [ m m ]
C o a x & P i p i n g W a t e r V o l u m e g a l [ l ]
Vertical
Air Coil Dimensions (H x W), in. [mm]
Filter Standard - 2” [51mm] Pleated MERV11 Throwaway, in [mm]
Weight - Operating, lb [kg]
Weight - Packaged, lb [kg]
Vertical
Horizontal
ND026
56 [1.58]
58 [1.64]
ND038
70 [1.98]
76 [2.15]
DUAL CAPACITY
ND049
Dual Capacity Scroll
93 [2.63]
93 [2.63]
ND064
112 [3.17]
112 [3.17]
ND072
130 [3.68]
136 [3.85]
V S E C M
5 S p d E C M
VS ECM
5-Spd ECM
V S E C M
VS ECM
5-Spd ECM
V S E C M
1/2 [373]
1/2 [373] n / a
9 x 7
[229 x 178]
9 x 7
[229 x 178] n / a
1/2 [373]
1/2 [373]
V a r i a b l e S p e e d E C M
5 S p e e d E C M
1/2 [373]
1 [746]
1 [746]
1 [746]
1 [ 7 4 6 ]
11 x 10
[279 x 254]
11 x 10
[279 x 254]
11 x 10
[279 x 254]
1 [ 7 4 6 ]
11 x 10
[279 x 254]
11 x 10
[279 x 254]
11 x 10
[279 x 254] n / a
11 x 10
[279 x 254]
11 x 10
[279 x 254] n/a
1 [746]
1 [746] n / a
11 x 10
[279 x 254]
11 x 10
[279 x 254] n/a
1 ” [ 2 5 .
4 ]
1 / 2 ” [ 1 2 .
7 ]
0 .
7 [ 2 .
6 ]
1 ” [ 2 5 .
4 ]
1 / 2 ” [ 1 2 .
7 ]
1 .
3 [ 4 .
9 ]
1 ” [ 2 5 .
4 ]
1 / 2 ” [ 1 2 .
7 ]
1 .
6 [ 6 .
1 ]
1 ” [ 2 5 .
4 ]
1 / 2 ” [ 1 2 .
7 ]
1 .
6 [ 6 .
1 ]
1 ” [ 2 5 .
4 ]
1 / 2 ” [ 1 2 .
7 ]
2 .
3 [ 8 .
7 ]
24 x 20
[610 x 542]
3 .
3 [ 0 .
3 1 0 ]
3/8 [9.5]
3
28 x 25
[711 x 635]
4 .
9 [ 0 .
4 5 1 ]
3/8 [9.5]
3
28 x 24
[712 x 610]
293 [133]
313 [142]
28 x 30
[712 x 762]
358 [162]
378 [172]
32 x 25
[813 x 635]
36 x 25
[914 x 635]
5 .
6 [ 0 .
5 7 0 ]
3/8 [9.5]
3
6 .
3 [ 0 .
6 4 1 ]
3/8 [9.5]
4
32 x 30
[813 x 762]
408 [185]
428 [194]
36 x 30
[914 x 762]
453 [205]
473 [215]
36 x 25
[914 x 635]
6 .
3 [ 0 .
6 4 1 ]
3/8 [9.5]
4
36 x 30
[914 x 762]
468 [212]
488 [221]
18 x 27
[457 x 686]
3 .
4 [ 0 .
3 1 6 ]
3/8 [9.5]
3
20 x 35
[508 x 889]
4 .
9 [ 0 .
4 5 1 ]
3/8 [9.5]
3
1 - 18 x 32
[457 x 813]
300 [136]
320 [145]
1 - 20 x 37
[686 x 940]
368 [167]
388 [176]
20 x 40
[508 x 1016]
5 .
6 [ 0 .
5 7 0 ]
3/8 [9.5]
3
1 - 20 x 20
[508 x 508]
1 - 20 x 22
[508 x 559]
418 [190]
438 [199]
20 x 45
[508 x 1143]
20 x 45
[508 x 1143]
6 .
3 [ 0 .
6 4 1 ]
3/8 [9.5]
4
6 .
3 [ 0 .
6 4 1 ]
3/8 [9.5]
4
1 - 20 x 25
[508 x 635]
1 - 20 x 22
[508 x 559]
463 [210]
483 [219]
1 - 20 x 25
[508 x 635]
1 - 20 x 22
[508 x 559]
480 [218]
500 [227]
7/15/2015
23
T1GX, T2GX SERIES SPECIFICATION CATALOG
Auxiliary Heat Ratings
Model
EAS(H)4A
EAM(H)5A
EAM(H)8A
EAM(H)10A
EAL(H)10A
208V
2.9
3.6
5.7
7.2
7.2
kW
230V
3.8
4.8
7.6
9.6
9.6
Stages
1
1
2
2
2
208V
Btu/h
230V
Min cfm
9,700 12,900 250
12,300 16,300 450
19,400 25,900 550
24,600 32,700 650
24,600 32,700 1100
EAL(H)15A
EAL(H)20A
10.8
14.4
14.4
19.2
3
4
36,900 49,100 1250
49,200 65,500 1500
Order the “H” part number when installed on horizontal and vertical rear discharge units
Air flow level for auxiliary heat (Aux) must be above the minimum cfm in this table
012
•
018
Model Size Compatibility
022 026 - 030 036 - 042 048 - 072
•
•
•
•
•
•
•
•
•
•
•
•
5/8/12
Auxiliary Heat Electrical Data
Model
EAS(H)4A
EAM(H)5A
EAM(H)8A
EAM(H)10A
EAL(H)10A
EAL(H)15A
EAL(H)20A
Supply
Circuit
Single
Single
Single
Single
Single
Single
L1/L2
L3/L4
Single
L1/L2
L3/L4
Heater Amps
208 V
13.7
17.3
27.5
34.7
34.7
52.0
34.7
17.3
69.3
34.7
34.7
240 V
15.8
20.0
31.7
40.0
40.0
60.0
40.0
20.0
80.0
40.0
40.0
39.3
48.3
53.3
75.0
53.3
21.7
Min Circuit Amp
208 V
17.9
26.7
240 V
20.5
30.0
44.6
55.0
60.0
85.0
96.7
53.3
43.3
All heaters rated single phase 60 cycle and include unit blower load
All fuses type “D” time delay (or HACR circuit breaker in USA)
Supply wire size to be determined by local codes
60.0
25.0
110.0
60.0
50.0
60
25
100
60
45
Fuse (USA)
208 V
20
30
240 V
20
30
40
50
60
80
45
60
60
90
60
25
110
60
50
60
25
100
60
45
Fuse (CAN)
208 V
20
30
240 V
20
30
40
50
60
80
45
60
60
90
60
25
110
60
50
60
20
100
60
40
40
50
60
70
CKT BRK
208 V
20
30
240 V
20
30
45
60
60
100
60
30
100
60
50
2/11/12
24
T1GX, T2GX SERIES SPECIFICATION CATALOG
Electrical Data
Single Speed Unit with Variable Speed ECM Motor
Compressor
Model Rated Voltage
Voltage
Min/Max MCC RLA LRA LRA**
HWG
Pump FLA
018
022
030
036
036*
042
042*
048
048*
060
070
208-230/60/1
208-230/60/1
208-230/60/1
208-230/60/1
208-230/60/1
208-230/60/1
208-230/60/1
208-230/60/1
208-230/60/1
208-230/60/1
208-230/60/1
* With optional 1 hp ECM motor
** With optional IntelliStart ®
Rated voltage of 208/230/60/1
All fuses Class RK-5
HACR circuit breaker in USA only
187/253
187/253
187/253
187/253
187/253
187/253
187/253
187/253
187/253
187/253
187/253
10.4
14.0
20.0
22.0
22.0
26.0
26.0
31.0
31.0
41.2
44.2
6.7
9.0
12.8
14.1
14.1
16.6
16.6
19.8
19.8
26.4
28.3
33.5
48.0
58.3
73.0
73.0
79.0
79.0
109.0
109.0
134.0
178.0
12.0
17.0
21.0
26.0
26.0
28.0
28.0
38.0
38.0
47.0
63.0
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
Single Speed Unit with 5-Speed ECM Motor
Compressor
Model
Rated
Voltage
Voltage
Min/Max MCC RLA LRA
022
030
036
042
048
060
070
208-230/60/1
208-230/60/1
208-230/60/1
208-230/60/1
208-230/60/1
208-230/60/1
208-230/60/1
** With optional IntelliStart ®
Rated voltage of 208/230/60/1
All fuses Class RK-5
HACR circuit breaker in USA only
187/253
187/253
187/253
187/253
187/253
187/253
187/253
14.0
20.0
22.0
26.0
31.0
41.2
44.2
9.0
12.8
14.1
16.6
19.8
26.4
28.3
48.0
58.3
73.0
79.0
109.0
134.0
178.0
LRA**
17.0
21.0
26.0
28.0
38.0
47.0
63.0
HWG
Pump
FLA
0.4
0.4
0.4
0.4
0.4
0.4
0.4
Single Speed Unit with PSC Motor
Compressor
Model Rated Voltage
Voltage
Min/Max MCC RLA LRA
042
042*
048
048*
060
070
012
018
022
022*
030
030*
036
036*
208-230/60/1
208-230/60/1
208-230/60/1
208-230/60/1
208-230/60/1
208-230/60/1
208-230/60/1
208-230/60/1
208-230/60/1
208-230/60/1
208-230/60/1
208-230/60/1
208-230/60/1
208-230/60/1
* With optional high static motor
** With optional IntelliStart ®
Rated voltage of 208/230/60/1
All fuses Class RK-5
HACR circuit breaker in USA only
187/253
187/253
187/253
187/253
187/253
187/253
187/253
187/253
187/253
187/253
187/253
187/253
187/253
187/253
26.0
26.0
31.0
31.0
41.2
44.2
7.7
10.4
14.0
14.0
20.0
20.0
22.0
22.0
16.6
16.6
19.8
19.8
26.4
28.3
4.9
6.7
9.0
9.0
12.8
12.8
14.1
14.1
79.0
79.0
109.0
109.0
134.0
158.0
25.0
33.5
48.0
48.0
58.3
58.3
73.0
73.0
LRA**
28.0
28.0
38.0
38.0
47.0
63.0
n/a
12.0
17.0
17.0
21.0
21.0
26.0
26.0
HWG
Pump FLA
0.4
0.4
0.4
0.4
0.4
0.4
-
0.4
0.4
0.4
0.4
0.4
0.4
0.4
Ext
Loop
FLA
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
Ext
Loop
FLA
5.4
5.4
5.4
5.4
Blower
Motor FLA
7.0
4.0
7.0
4.0
7.0
7.0
7.0
4.0
4.0
4.0
4.0
5.4
5.4
5.4
5.4
5.4
5.4
Ext
Loop
FLA
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
Blower
Motor FLA
3.5
4.6
3.5
4.6
5.9
5.9
0.6
1.1
1.2
1.5
1.5
2.8
2.8
3.5
Blower
Motor
FLA
4.1
4.1
4.1
7.6
7.6
7.6
7.6
26.9
26.4
29.4
29.6
32.6
39.2
41.1
Total
Unit
FLA
16.5
18.8
22.6
23.9
Total
Unit
FLA
18.9
22.7
24.0
30.0
33.2
39.8
41.7
21.4
22.7
23.4
25.9
27.0
29.1
Total
Unit
FLA
10.9
13.6
16.0
16.3
20.1
30.2
38.1
41.8
30.4
30.6
33.6
34.6
37.6
45.8
48.2
Min
Circ
Amp
18.1
21.0
25.8
27.4
Max
Fuse/
HACR
20
30
35
40
50
50
70
40
45
50
70
9/27/12
Min
Circ
Amp
21.1
25.9
27.5
34.2
38.2
46.4
48.8
Max
Fuse/
HACR
30
35
40
50
50
70
70
4/6/12
24.6
26.2
26.9
30.1
31.2
34.1
Min
Circ
Amp
12.2
15.2
18.2
18.5
23.3
35.2
44.7
49.3
45
45
50
35
40
40
Max
Fuse/
HACR
15
20
25
25
35
50
70
70
09/27/12
25
T1GX, T2GX SERIES SPECIFICATION CATALOG
Electrical Data cont.
Dual Capacity Unit with Variable Speed ECM Motor
Compressor
Model
Rated
Voltage
Voltage
Min/Max MCC RLA LRA LRA**
026
038
038*
049
049*
064
072
208-230/60/1
208-230/60/1
208-230/60/1
208-230/60/1
208-230/60/1
208-230/60/1
208-230/60/1
* With optional 1 hp ECM motor
** With optional IntelliStart ®
Rated voltage of 208/230/60/1
All fuses Class RK-5
HACR circuit breaker in USA only
187/253
187/253
187/253
187/253
187/253
187/253
187/253
18.2
23.8
23.8
33.0
33.0
42.3
46.3
11.6
15.2
15.2
21.1
21.1
27.1
29.6
58.3
83.0
83.0
104.0
104.0
152.9
179.2
21.0
30.0
30.0
37.0
37.0
54.0
63.0
HWG
Pump
FLA
0.4
0.4
0.4
0.4
0.4
0.4
0.4
Dual Capacity Unit with 5-Speed ECM Motor
Compressor
Model
Rated
Voltage
Voltage
Min/Max MCC RLA LRA
026
038
049
064
072
208-230/60/1
208-230/60/1
208-230/60/1
208-230/60/1
208-230/60/1
** With optional IntelliStart ®
Rated voltage of 208/230/60/1
All fuses Class RK-5
HACR circuit breaker in USA only
187/253
187/253
187/253
187/253
187/253
18.2
23.8
33.0
42.3
46.3
11.6
15.2
21.1
27.1
29.6
58.3
83.0
104.0
152.9
179.2
LRA**
21.0
30.0
37.0
54.0
63.0
HWG
Pump
FLA
0.4
0.4
0.4
0.4
0.4
Ext
Loop
FLA
5.4
5.4
5.4
5.4
5.4
5.4
5.4
Blower
Motor
FLA
4.0
4.0
7.0
4.0
7.0
7.0
7.0
Total
Unit
FLA
21.4
25.0
28.0
30.9
33.9
39.9
42.4
Ext
Loop
FLA
5.4
5.4
5.4
5.4
5.4
Blower
Motor
FLA
4.1
4.1
7.6
7.6
7.6
Total
Unit
FLA
21.5
25.1
34.5
40.5
43.0
Min
Circ
Amp
24.4
28.8
31.8
36.2
39.2
46.6
49.8
Max
Fuse/
HACR
35
40
50
50
60
70
70
4/6/12
Min
Circ
Amp
24.5
28.9
39.8
47.2
50.4
Max
Fuse/
HACR
35
40
60
70
80
4/6/12
26
T1GX, T2GX SERIES SPECIFICATION CATALOG
Blower Performance Data
Single Speed Unit with Variable Speed ECM Motor
MODEL
022
030
036
036 w/1hp*
042
042 w/1hp*
048
048 w/1hp*
060
070
MAX
ESP
0.50
0.50
0.50
0.75
0.50
0.75
0.50
0.75
0.75
0.75
1
650
800
650
800
650
800
800
800
2
400
400
750
1000
L
800
900
L
800
900
950
950
3
500
L
500
L
850
L
1100
M
900
L
1000
900
1000
L
1100
L
1100
L
4
600
M
600
1000
1300
H
1050
1200
M
1050
L
1200
1300
1300
AIR FLOW DIP SWITCH SETTINGS
5 6 7
700 800
H
900
800 700
M
1100
M
1500
1200
1600
900
H
1300
H
1800
1150
M
1400
H
1150
1400
M
1500
M
1500
1250
1600
1250
1600
H
1750
1750
M
1350
1700
1350
M
1700
1950
H
1950
Factory settings are at recommended L-M-H DIP switch locations
M-H settings MUST be located within boldface CFM range
Lowest and Highest DIP switch settings are assumed to be L and H respectively
8
1000
1000
1400
1450
H
1850
1450
1850
2100
2100
H
9
1100
1100
1500
1550
2000
1550
H
2000
2300
2300
10
1200
1200
2200
2200
CFM is controlled within ±5% up to the maximum ESP
Max ESP includes allowance for wet coil and standard filter
11
2300
2300
Dual Capacity Unit with Variable Speed ECM Motor
MODEL
026
038
038 w/1hp*
049
049 w/1hp*
064
072
MAX
ESP
0.50
0.50
0.75
0.50
0.75
0.75
0.75
1
650
800
L
650
800
L
800
800
2
400
750
L
1000
800
L
900
950
L
950
3
500
L
850
1100
M
900
1000
1100
1100
L
4
600
1000
1300
H
1050
1200
1300
1300
AIR FLOW DIP SWITCH SETTINGS
5 6 7
800 700
M
1100
M
1500
1200
1600
900
H
1300
H
1800
1150
1400
M
1500
M
1500
1250
1600
H
1750
1750
M
1350
M
1700
1950
H
1950
Factory settings are at recommended L-M-H DIP switch locations
M-H settings MUST be located within boldface CFM range
Lowest and Highest DIP switch settings are assumed to be L and H respectively
8
1000
1400
1450
1850
2100
2100
H
9
1100
1500
1550
H
2000
2300
2300
10
1200
2200
CFM is controlled within ±5% up to the maximum ESP
Max ESP includes allowance for wet coil and standard filter
11
2300
12
2400
2400
5/30/06
12
2400
5/30/06
27
T1GX, T2GX SERIES SPECIFICATION CATALOG
Blower Performance Data cont.
Setting Variable Speed ECM Blower Speed
ECM blower motors have a 12-speed selector dip switch on the logic board (SW1) and are factory set for optimum performance. To change speeds, select the appropriate speeds on dip switch SW1. Consult the ECM blower performance table below for specifi c airfl ow and switch information.
A 12-position DIP switch package on the control allows the airflow levels to be set for low, medium, and high speed when using the ECM blower motor. Only three of the DIP switches can be in the "on" position.
• The second "on" switch determines the medium speed blower setting.
• The third "on" switch determines the high speed blower setting.
The example to the right shows SW1 on the control board configured for the following 042 airflow settings.
• Low Speed Blower: 900 CFM
• Medium Speed Blower: 1150 CFM
• High Speed Blower: 1450 CFM
CAUTION: Disconnect all power before performing this operation.
10
11
12
7
8
9
4
5
6
1
2
3
28
T1GX, T2GX SERIES SPECIFICATION CATALOG
Blower Performance Data cont.
Single Speed Unit with 5-Speed ECM Motor
Model
Motor
Speed
High
Med High
Motor
Tap
5
4
T’stat
Cnct.
W
Y1
Blower
Size
Motor
HP 0 0.05
0.10
0.15
Airflow (cfm) at External Static Pressure (in. wg)
0.20
0.25
0.30
0.35
0.40
0.45
0.50
0.60
0.70
980 960 940 930 920 905 890 875 860 840 820 800 745
0.80
-
0.90
-
1.00
-
890 878 865 845 825 813 800 785 770 753 735 710 665 -
022
030
036
Med
Med Low
Low
High
Med High
Med
Med Low
Low
High
Med High
Med
Med Low
Low
High
Med High
5
4
2
1
4
3
1
5
4
3
2
1
5
3
2 G
W
Y1
G
W
Y1
G
9 x 7
9 x 7
11 x 10
1/2
1/2
1/2
830 815 800 788 775 755 735 723 710 690 670 640 600
780 760 740 703 665 653 640 620 600 585 570 -
625 593 560 535 510 495 480 455 430 410 390 -
1407 1381 1354 1327 1300 1267 1233 1201 1168 1131 1094 1009
-
-
1146 1134 1122 1111 1099 1085 1071 1062 1052 1042 1031 966
1023 1012 1001 985 969 959 949 937 925 913 901 -
978 962 946 934 922 907 891 882 872 858 843 -
-
-
-
795 777 759 748 737 718 698 686 673 650 626 -
1530 1503 1476 1453 1429 1413 1397 1376 1355 1342 1329 1276 1231 1173
1413 1388 1363 1342 1321 1303 1285 1263 1240 1226 1212 1173 1016 946
1355 1325 1294 1276 1258 1235 1212 1188 1164 1144 1123 982 909 883
1336 1299 1261 1242 1222 1202 1181 1157 1132 1111 1090 937 874 830
1243 1182 1121 1061 1000 964 928 856 784 744 703 647 592
1934 1910 1886 1871 1855 1827 1799 1780 1760 1747 1734 1700 1659 1617
1799 1783 1767 1744 1720 1693 1666 1649 1631 1617 1603 1560 1530 1492
-
-
-
-
-
-
-
W
042
048
Med
Med Low
Low
High
Med High
Med
Med Low
Low
High
1
5
3
2
1
5
3
2
4
Y1
G
W
Y1
11 x 10
11 x 10
1
1
1694 1680 1666 1642 1617 1592 1567 1552 1537 1519 1500 1453 1421 1372
1575 1560 1540 1520 1502 1487 1471 1448 1424 1409 1393 1351 1308 1266
1454 1406 1358 1333 1308 1285 1261 1239 1217 1198 1179 1072 1002 988
1934 1910 1886 1871 1855 1827 1799 1780 1760 1747 1734 1700 1659 1617
1799 1783 1767 1744 1720 1693 1666 1649 1631 1617 1603 1560 1530 1492
-
-
-
-
-
1694 1680 1666 1642 1617 1592 1567 1552 1537 1519 1500 1453 1421 1372
1575 1560 1540 1520 1502 1487 1471 1448 1424 1409 1393 1351 1308 1266 -
-
-
-
1454 1406 1358 1333 1308 1285 1261 1239 1217 1198 1179 1072 1002 988 -
2245 2230 2214 2194 2173 2155 2136 2120 2103 2087 2070 2032 1998 1957 1910 1825
-
-
-
-
-
G
W
060
Med High
Med
Med Low
Low
High
Med High
Med
4
3
2
1
5
4
3
11 x 10 1
2092 2073
1931
2054
1910
2035
1889
2015
1868
1995
1850
1975
1831
1958
1812
1940
1793
1922
1774
1904
1755
1880
1722
1843
1688
1806
1654
1767
1612
1728
1562
Y1 1812 1796 1780 1761 1741 1718 1695 1682 1668 1651 1633 1591 1555 1518 1480 1433
G 1682 1661 1640 1616 1591 1573 1555 1533 1510 1495 1480 1441 1400 1351 1316 1263
W
Y1
2472
2271
2454
2248
2435
2225
2414
2205
2393
2184
2371
2166
2349
2147
2328
2129
2306
2110
2289
2094
2271
2078
2230
2039
2189
2011
2121
1977
2033
1930
1936
1846
070 11 x 10 1 2133 2115 2096 2072 2047 2030 2013 1996 1979 1965 1950 1909 1873 1837 1793 1748
Med Low
Low
2
1 G
Factory speed settings are in Bold
Air flow values are with dry coil and standard filter
2008
1806
1985
1784
1962
1761
1939
1742
1915
1722
1898
1696
1880
1669
1862
1656
1843
1642
1828
1625
For wet coil performance first calculate the face velocity of the air coil (Face Velocity [fpm] = Airflow [cfm] / Face Area [sq ft]).
1812
1607
1774
1564
1742
1527
1703
1490
1669
1443
1635
1404
6/14/12
Then for velocities of 200 fpm reduce the static capability by 0.03 in. wg, 300 fpm by 0.08 in. wg, 400 fpm by 0.12in. wg., and 500 fpm by 0.16 in. wg.
Highest setting is for auxiliary heat (W) and lowest setting is for constant blower (G). The “Y1” and “Y2” settings must be between the
“G” and “W” settings.
The gray wire is not factory wired to the motor and is tied to the wire harness. This wire can be field connected and can be used with 3HT/2CL thermostats or IntelliZone2 to deliver the required air flow for the Y2 signal.
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
5-Speed ECM Constant Torque Motors
The 5-Speed ECM is a ‘Constant Torque’ ECM motor and delivers air flow similar to a PSC but operates as efficiently as an ECM Motor.
Because it’s an ECM Motor, the 5-Speed ECM can ramp slowly up or down like the ECM motor. There are 5 possible speed taps available on the 5-Speed ECM motor with #1 being the lowest airflow and #5 being the highest airflow. These speed selections are preset at the time of manufacture and are easily changed in the field if necessary.
If more than one tap are energized at the same time, built in logic gives precedence to the highest tap number and allows air flow to change with G, Y1, Y2 and W signals or with Fan, CC, CC2, and
E1 output signals. Each of those 5 speeds has a specific ‘Torque’ value programmed into the motor for each speed selection. As static pressure increases, airflow decreases resulting in less torque on the rotor. The motor responds only to changes in torque and adjusts its speed accordingly.
The 5-Speed ECM motor is powered by line voltage but the motor speed is energized by 24 VAC.
5-Speed ECM Benefits:
- 5 speeds with up to 4 speeds on-line
- Built in logic allows air flow to change with G, Y1, Y2 and W signals
- Super efficient low airflow continuous blower setting (G)
29
T1GX, T2GX SERIES SPECIFICATION CATALOG
Blower Performance Data cont.
Dual Capacity Unit with 5-Speed ECM
Model
Motor
Speed
High
Med High
Motor
Tap
5
4
T’stat
Cnct.
W
Y2
Blower
Size
Motor
HP 0 0.05
0.10
0.15
Airflow (cfm) at External Static Pressure (in. wg)
0.20
0.25
0.30
0.35
0.40
0.45
0.50
0.60
0.70
1120 1109 1097 1082 1066 1055 1044 1028 1011 1001 991 932 839
0.80
-
0.90
-
1.00
-
1020 1006 991 980 968 950 932 922 911 894 876 849 812 -
026
038
Med
Med Low
Low
High
Med High
Med
Med Low
Low
High
1
5
4
3
2
1
5
3
2
Y1
G
W
Y2
Y1
G
W
9 x 7
11 x 10
1/2
1/2
917 906 895 884 872 854 836 824 812 792 772 754 719
836 824 812 794 776 765 754 735 715 703 691 653 631 -
-
735 721 707 687 666 653 640 622 603 589 574 533 -
1530 1503 1476 1453 1429 1413 1397 1376 1355 1342 1329 1276 1231 1173
1413 1388 1363 1342 1321 1303 1285 1263 1240 1226 1212 1173 1016 946
1355 1325 1294 1276 1258 1235 1212 1188 1164 1144 1123 982 909 883
1336 1299 1261 1242 1222 1202 1181 1157 1132 1111 1090 937 874 830
1243 1182 1121 1061 1000 964 928 856 784 744 703 647 592
1934 1910 1886 1871 1855 1827 1799 1780 1760 1747 1734 1700 1659 1617
-
-
-
-
-
-
-
-
-
049
Med High
Med
Med Low
Low
High
Med High
4
3
2
1
5
4
Y2
Y1
G
W
Y2
11 x 10 1
1799
1694
1575
1783
1680
1560
1767
1666
1540
1744
1642
1520
1720
1617
1502
1693
1592
1487
1666
1567
1471
1649
1552
1448
1631
1537
1424
1617
1519
1409
1603
1500
1393
1560
1453
1351
1530
1421
1308
1492
1372
1266
1454 1406 1358 1333 1308 1285 1261 1239 1217 1198 1179 1072 1002 988
-
-
-
-
-
-
-
-
2245 2230 2214 2194 2173 2155 2136 2120 2103 2087 2070 2032 1998 1957 1910 1825
2092 2073 2054 2035 2015 1995 1975 1958 1940 1922 1904 1880 1843 1806 1767 1728
064
072
Med
Med Low
Low
High
Med High
Med
Med Low
3
2
1
5
4
3
2
Y1
11 x 10 1 1931 1910 1889 1868 1850 1831 1812 1793 1774 1755 1722 1688 1654 1612 1562
1812 1796 1780 1761 1741 1718 1695 1682 1668 1651 1633 1591 1555 1518 1480 1433
G 1682 1661 1640 1616 1591 1573 1555 1533 1510 1495 1480 1441 1400 1351 1316 1263
W
Y2
11 x 10 1
2472 2454 2435 2414 2393 2371 2349 2328 2306 2289 2271 2230 2189 2121 2033 1936
2271 2248 2225 2205 2184 2166 2147 2129 2110 2094 2078 2039 2011 1977 1930 1846
2133 2115 2096 2072 2047 2030 2013 1996 1979 1965 1950 1909 1873 1837 1793 1748
2008 1985 1962 1939 1915 1898 1880 1862 1843 1828 1812 1774 1742 1703 1669 1635 Y1
Low 1 G
Factory speed settings are in Bold
Air flow values are with dry coil and standard filter
1806 1784 1761 1742 1722 1696 1669 1656 1642 1625 1607 1564 1527 1490
For wet coil performance first calculate the face velocity of the air coil (Face Velocity [fpm] = Airflow [cfm] / Face Area [sq ft]).
Then for velocities of 200 fpm reduce the static capability by 0.03 in. wg, 300 fpm by 0.08 in. wg, 400 fpm by 0.12in. wg., and 500 fpm by 0.16 in. wg.
Highest setting is for auxiliary heat (W) and lowest setting is for constant blower (G). The “Y1” and “Y2” settings must be between the
“G” and “W” settings.
1443 1404
6/14/12
-
-
-
-
-
-
-
-
-
Setting Blower Speed - 5-Speed ECM
5-Speed ECM blower motors have five (5) speeds of which three
(3) are selectable on single speed and four (4) are selectable on dual capacity.
CAUTION: Disconnect all power before performing this operation.
5-Speed ECM Motor Connections - Single Speed
C
High Voltage
Connections
3/16 in.
L G N
C - Black
L - Orange
G - Green
N - Brown
G - Blue
Y1 - Red
1 2 3 4
Low Voltage
Connections 1/4 in.
5
AUX - Gray
5-Speed ECM Motor Connections - Dual Capacity
C
High Voltage
Connections
3/16 in.
L G N
C - Black
L - Orange
G - Green
N - Brown
G - Blue
Y1 - Red
1 2 3 4
Low Voltage
Connections 1/4 in.
5
AUX - Gray
Y2 - Tan
30
T1GX, T2GX SERIES SPECIFICATION CATALOG
Blower Performance Data cont.
Unit with Standard PSC Motor
Model
012
018
022
L
H
M
L
L
H
M
Motor
Spd
H
MH*
ML
Blower
Size
6 x 8
9 x 7
9 x 7
Motor
HP
1/10
1/6
1/5
0
480
440
395
325
845
735
0.05
450
410
370
310
835
730
0.10
440
400
360
300
825
725
0.15
420
380
340
280
815
715
0.20
410
370
330
270
800
705
Airflow (cfm) at External Static Pressure (in. wg)
0.25
380
350
310
250
790
700
620 615 610 605 600 590
1110 1095 1080 1065 1045 1020
850
750
845
745
835
740
825
735
815
725
805
715
0.30
360
330
290
240
775
690
580
995
795
700
0.35
340
310
280
230
755
675
565
970
775
685
0.40
330
300
270
220
735
660
550
945
755
670
0.45
310
280
250
210
710
630
520
915
735
650
0.50
300
270
240
200
680
600
490
880
715
630
0.60
810
-
-
-
-
-
-
-
565
485
030
036
042
048
060
070
H
M
L
H
M
L
H
M
L
H
M
L
H
M
L
H
M
L
9 x 7
10 x 10
10 x 10
10 x 10
11 x 10
11 x 10
1/3
1/2
1/2
1/2
1
1
1290 1270 1245 1220 1190 1160 1125 1090 1055 1020
1100 1090 1075 1060 1045 1020 995 970 940 910
910 905 900 895 885 875 865 850 835 810
1665 1640 1610 1580 1550 1515 1480 1450 1415 1315 1215 1090
1465 1445 1425 1400 1375 1350 1325 1260 1190 1140 1090
1130 1115 1100 1090 1075 1035 995 965 930 895
985
875
780
860
880
785
710
990
795
980
890
730
2010 1975 1940 1905 1870 1825 1780 1735 1690 1640 1590 1470 1210
1670 1650 1630 1610 1590 1560 1530 1495 1460 1425 1390 1190 1080
1220 1215 1210 1295 1200 1180 1160 1130 1100 1060 1020 930 -
760
625
560
-
-
-
-
0.70
-
-
-
-
-
-
-
-
-
-
-
-
-
0.80
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
2010 1975 1940 1905 1870 1825 1780 1735 1690 1640 1590 1470 1210
1670 1650 1630 1610 1590 1560 1530 1495 1460 1425 1390 1190 1080
1220 1215 1210 1295 1200 1180 1160 1130 1100 1060 1020 930 -
-
-
-
-
-
-
-
-
-
2430 2400 2365 2330 2290 2255 2215 2180 2140 2095 2045 1945 1835 1715 1510 1330
2265 2235 2205 2175 2145 2110 2070 2035 2000 1960 1915 1825 1730 1605 1440 1260
2075 2050 2020 1995 1965 1940 1915 1885 1850 1820 1785 1720 1610 1505 1335 1175
-
-
-
-
-
-
-
-
-
-
1.00
-
-
-
-
-
-
-
-
-
-
-
-
-
0.90
-
-
-
-
-
-
-
-
-
2430 2400 2365 2330 2290 2255 2215 2180 2140 2095 2045 1945 1835 1715 1510 1330
2265 2235 2205 2175 2145 2110 2070 2035 2000 1960 1915 1825 1730 1605 1440 1260
2075 2050 2020 1995 1965 1940 1915 1885 1850 1820 1785 1720 1610 1505 1335 1175
2/7/12
Unit with Optional High Static PSC Motor
Model
022
030
Motor
Spd
H
M
L
H
M
L
H
Blower
Size
9 x 7
9 x 7
Motor
HP
1/3
1/2
0 0.05
0.10
0.15
0.20
Airflow (cfm) at External Static Pressure (in. wg)
0.25
0.30
0.35
0.40
0.45
1290 1270 1245 1220 1190 1160 1125 1090 1055 1020
0.50
985
0.60
880
1100 1090 1075 1060 1045 1020 995 970 940 910 875 785
910 905 900 895 885 875 865 850 835 810 780
1365 1340 1325 1305 1280 1250 1215 1180 1140 1100 1055
710
960
0.70
760
625
560
850
0.80
-
-
-
-
1040 1040 1035 1030 1020 1005
880 880 880 880 875 870
990
860
970
840
945
820
915
800
885
775
810
730
735
480
-
-
1930 1905 1875 1840 1805 1765 1725 1680 1635 1530 1425 1270 1150 1025
036
042
M
L
H
M
10 x 10
10 x 10
1/2
3/4
1635 1620 1600 1580 1555 1530 1505 1465 1425 1335 1240 1135 1035
1230 1230 1225 1215 1200 1165 1130 1095 1060 1035 1005 935 795
775
675
2115 2075 2035 1980 1920 1900 1880 1840 1795 1730 1660 1390 1225 1070
2005 1980 1950 1910 1865 1815 1765 1725 1685 1585 1485 1315 1140 1025
048
L
H
M
L
10 x 10 3/4
1860
2115 2075 2035 1980 1920 1900 1880 1840 1795 1730 1660 1390 1225 1070
2005
1860
1835
1980
1835
1805
1950
1805
1780
1910
1780
1750
1865
1750
1715
1815
1715
1675
1765
1675
1635
1725
1635
1590
1685
1590
1540
1585
1540
1490
1485
1490
1260
1315
1260
Factory settings are in Bold
High-Static option not available for 012, 018, 060, and 070
Air flow values are with dry coil and standard filter
For wet coil performance first calculate the face velocity of the air coil (Face Velocity [fpm] = Airflow [cfm] / Face Area [sq ft]).
Then for velocities of 200 fpm reduce the static capability by 0.03 in. wg, 300 fpm by 0.08 in. wg, 400 fpm by 0.12in. wg. and 500 fpm by
0.16 in. wg.
1115
1140
1115
980
1025
980
-
-
-
-
-
-
-
1.00
-
-
-
-
-
-
-
-
1/25/12
-
-
-
-
-
-
-
-
-
-
-
0.90
-
-
-
-
Setting Blower Speed - PSC
CAUTION: Disconnect all power before performing this operation.
R
E
W
O
S
P
E
E
D
W
IR
E
HIGH MEDIUM LOW
PSC BLOWER MOTOR BODY
31
T1GX, T2GX SERIES SPECIFICATION CATALOG
Reference Calculations
Heating Calculations:
LWT = EWT -
HE gpm x 500
LAT = EAT +
HC cfm x 1.08
TH = HC + HW
Cooling Calculations:
LWT = EWT +
HR gpm x 500
LAT (DB) = EAT (DB) -
SC cfm x 1.08
LC = TC - SC
S/T =
SC
TC
Legend and Notes
Abbreviations and Definitions
cfm = airflow, cubic feet/minute
EWT = entering water temperature, Fahrenheit gpm = water flow in gallons/minute
WPD = water pressure drop, psi and feet of water
EAT = entering air temperature, Fahrenheit (dry bulb/wet bulb)
HC = air heating capacity, MBtu/h
TC = total cooling capacity, MBtu/h
SC = sensible cooling capacity, MBtu/h kW = total power unit input, kilowatts
HR = total heat of rejection, MBtu/h
HE = total heat of extraction, MBtu/h
HWC = hot water generator capacity, MBtu/h
EER = Energy Efficient Ratio
= Btu output/Watt input
COP = Coefficient of Performance
= Btu output/Btu input
LWT = leaving water temperature, °F
LAT = leaving air temperature, °F
TH = total heating capacity, MBtu/h
LC = latent cooling capacity, MBtu/h
S/T = sensible to total cooling ratio
Notes to Performance Data Tables
The following notes apply to all performance data tables:
• Performance ratings are based on 80°F DB/67°F WB EAT for cooling and 70°F DB EAT for heating.
• Three flow rates are shown for each unit. The lowest flow rate shown is used for geothermal open loop/well water systems with a minimum of 50°F EWT. The middle flow rate shown is the minimum geothermal closed loop flow rate. The highest flow rate shown is optimum for geothermal closed loop systems and the suggested flow rate for boiler/tower applications.
• The hot water generator numbers are based on a flow rate of 0.4 gpm/ton of rated capacity with an EWT of 90°F.
• Entering water temperatures below 40°F assumes 15% antifreeze solution.
• For non-standard EAT conditions, apply the appropriate Correction Factor tables.
• Interpolation between EWT, gpm, and cfm data is permissible, extrapolation is not.
32
T1GX, T2GX SERIES SPECIFICATION CATALOG
Operating Limits
Operating Limits
Air Limits
Min. Ambient Air
Rated Ambient Air
Max. Ambient Air
Min. Entering Air
Rated Entering Air db/wb
Max. Entering Air db/wb
Water Limits
Min. Entering Water
Normal Entering Water
Max. Entering Water
(°F)
Cooling
(°C)
45
80
100
50
80.6/66.2
110/83
7.2
26.7
37.8
10.0
27/19
43/28.3
30
50-110
120
-1.1
10-43.3
48.9
(°F)
Heating
(°C)
45
70
85
40
68
80
20
30-70
90
-6.7
-1.1
32.2
7.2
21.1
29.4
4.4
20.0
26.7
NOTE: Minimum/maximum limits are only for start-up conditions, and are meant for bringing the space up to occupancy temperature. Units are not designed to operate at the minimum/maximum conditions on a regular basis. The operating limits are dependent upon three primary factors: 1) water temperature, 2) return air temperature, and 3) ambient temperature. When any of the factors are at the minimum or maximum levels, the other two factors must be at the normal level for proper and reliable unit operation.
33
T1GX, T2GX SERIES SPECIFICATION CATALOG
Antifreeze Corrections
Catalog performance can be corrected for antifreeze use. Please use the following table and note the example given.
Antifreeze Type
EWT - °F [°C]
Water
Ethylene Glycol
Propylene Glycol
Ethanol
Methanol
Antifreeze % by wt
50
10
20
20
30
40
30
40
50
10
0
10
20
20
30
40
30
40
50
10
50
Heating
30 [-1.1]
1.000
0.973
0.943
0.917
0.890
0.865
0.958
0.913
0.854
0.813
0.770
0.927
0.887
0.856
0.815
0.779
0.957
0.924
0.895
0.863
0.833
WARNING: Gray area represents antifreeze concentrations greater than 35% by weight and should be avoided due to the extreme performance penalty they represent.
Cooling
90 [32.2]
1.000
0.991
0.979
0.965
0.955
0.943
0.981
0.969
0.950
0.937
0.922
0.991
0.972
0.947
0.930
0.911
0.986
0.970
0.951
0.936
0.920
Pressure Drop
30 [-1.1]
1.000
1.075
1.163
1.225
1.324
1.419
1.130
1.270
1.433
1.614
1.816
1.242
1.343
1.383
1.523
1.639
1.127
1.197
1.235
1.323
1.399
Antifreeze Correction Example
Antifreeze solution is Propylene Glycol 20% by weight. Determine the corrected heating and cooling performance at 30°F and 90°F respectively as well as pressure drop at 30°F for Single Speed Model 022-ECM.
The corrected cooling capacity at 90°F would be: 22,400 MBtu/h x 0.969 = 21,706 MBtu/h
The corrected heating capacity at 30°F would be: 14,500 MBtu/h x 0.913 = 13,239 MBtu/h
The corrected pressure drop at 30°F and 6 gpm would be: 6.6 feet of head x 1.270 = 8.38 feet of head
34
T1GX, T2GX SERIES SPECIFICATION CATALOG
Correction Factor Tables
Air Flow Corrections (Dual Capacity Part Load)
cfm Per Ton of Clg
240
Airflow
% of Nominal
60
Total Cap
0.922
Sens Cap
0.778
Cooling
400
425
450
475
500
520
275
300
325
350
375
100
106
113
119
125
130
69
75
81
88
94
0.944
0.957
0.970
0.982
0.991
1.000
1.007
1.013
1.017
1.020
1.022
0.830
0.866
0.900
0.933
0.968
1.000
1.033
1.065
1.099
1.132
1.159
Power
1.000
1.011
1.023
1.037
1.052
1.064
0.956
0.962
0.968
0.974
0.981
0.991
Air Flow Corrections (Dual Capacity Full Load and Single Speed)
Airflow cfm Per Ton of Clg
% of Nominal
240
275
60
69
300
325
75
81
Total Cap
0.922
0.944
0.959
0.971
Sens Cap
0.786
0.827
0.860
0.894
Cooling
Power
0.910
0.924
0.937
0.950
350
375
400
425
450
475
500
520
88
94
100
106
113
119
125
130
0.982
0.992
1.000
1.007
1.012
1.017
1.019
1.020
0.929
0.965
1.000
1.034
1.065
1.093
1.117
1.132
0.964
0.982
1.000
1.020
1.042
1.066
1.092
1.113
Heat of Rej
0.920
0.940
0.955
0.967
0.978
0.990
1.000
1.010
1.018
1.026
1.033
1.038
Heat of Rej
1.000
1.008
1.015
1.022
1.027
1.030
0.924
0.944
0.958
0.970
0.980
0.991
Cooling Capacity Corrections
Entering
Air WB °F
55
60
63
65
66.2
Total
Clg Cap
0.898
0.912
0.945
0.976
0.983
60
0.723
65
0.866
0.632
Sensible Cooling Capacity Multipliers - Entering DB °F
70 75 80 80.6
85 90
1.048
0.880
0.768
0.694
0.655
1.185
1.078
0.960
0.881
0.842
67
70
1.000
1.053
0.616
0.806
0.693
75 1.168
NOTE: * Sensible capacity equals total capacity at conditions shown.
*
1.244
1.150
1.079
1.040
1.000
0.879
0.687
*
1.260
1.175
1.085
1.060
1.023
0.900
0.715
*
*
*
1.270
1.232
1.193
1.075
0.875
*
*
*
*
*
1.330
1.205
1.040
Heating Capacity Corrections
Ent Air DB °F
45
50
55
60
65
68
70
75
80
Htg Cap
1.062
1.050
1.037
1.025
1.012
1.005
1.000
0.987
0.975
Heating Corrections
Power
0.739
0.790
0.842
0.893
0.945
0.976
1.000
1.048
1.099
Heat of Ext
1.158
1.130
1.096
1.064
1.030
1.012
1.000
0.970
0.930
11/10/09
35
Htg Cap
0.943
0.958
0.968
0.977
0.985
0.993
1.000
1.007
1.013
1.018
1.023
1.026
*
*
*
*
95
*
1.480
1.404
1.261
Htg Cap
1.000
1.007
1.012
1.018
1.022
1.025
0.943
0.958
0.968
0.977
0.985
0.993
Heating
Power
1.150
1.105
1.078
1.053
1.031
1.014
1.000
0.990
0.983
0.980
0.978
0.975
Heating
Power
1.000
0.990
0.987
0.984
0.982
0.979
1.239
1.161
1.115
1.075
1.042
1.018
Heat of Ext
0.879
0.914
0.937
0.956
0.972
0.988
1.000
1.010
1.018
1.025
1.031
1.034
5/30/06
Heat of Ext
0.893
0.922
0.942
0.959
0.973
0.988
1.000
1.011
1.020
1.028
1.034
1.038
5/30/06
100
*
*
*
*
*
*
*
1.476
Power
Input
0.985
0.994
0.996
0.997
0.999
1.000
1.003
1.007
Heat of
Rejection
0.913
0.927
0.954
0.972
0.986
1.000
1.044
1.141
3/28/12
T1GX, T2GX SERIES SPECIFICATION CATALOG
Pressure Drop
Single Speed
Model gpm
012
018
022
030
036
042
048
060
070
4.5
6.8
1.0
2.1
3.6
2.8
4.7
1.3
2.7
6.3
0.8
2.1
4.2
2.5
1.6
2.9
4.2
30°F
0.3
1.0
1.7
6.0
0.9
1.7
3.0
4.4
6.0
9.7
2.4
3.9
5.7
9.5
7.6
1.1
2.3
3.9
6.7
8
10
5
7
9
4
6
6
8
12
5
8
11
1.5
2.5
3.5
4.5
3.0
4.0
5.0
6.0
3
4.5
12
15
18
24
9
12
15
20
14
6
9
12
16
2.8
4.0
5.5
9.1
2.2
3.6
5.3
8.9
6.7
1.0
2.1
3.7
6.3
4.2
6.3
1.0
1.9
3.3
5.9
0.7
2.1
4.1
2.9
4.2
5.8
0.9
1.6
2.7
4.4
1.2
2.5
Pressure Drop (psi)
50°F 70°F 90°F
0.3
0.3
0.3
1.0
1.7
2.4
1.6
1.0
1.7
2.4
1.5
1.0
1.6
2.4
1.5
2.8
4.1
5.7
0.8
1.5
2.5
4.1
1.2
2.4
2.8
4.0
5.6
0.7
1.4
2.3
3.9
1.1
2.2
2.6
3.8
5.1
8.5
2.1
3.4
5.0
8.3
6.3
1.0
2.0
3.4
5.9
3.9
5.4
0.9
1.8
3.0
5.5
0.7
1.9
3.8
2.4
3.5
4.8
7.9
2.0
3.2
4.7
7.8
5.8
0.9
1.9
3.2
5.5
3.7
5.4
0.8
1.7
2.8
5.1
0.7
1.8
3.5
5.4
0.8
1.7
3.0
5.1
1.8
2.9
4.3
7.2
2.2
3.3
4.4
7.3
2/7/12
3.4
5.0
0.8
1.6
2.6
2.2
3.6
1.0
2.2
4.8
0.6
1.7
3.3
110°F
0.3
1.0
1.6
2.3
1.4
2.7
3.9
5.5
0.7
1.3
Dual Capacity
Model gpm
026 full load
026 part load
038 full load
038 part load
049 full load
049 part load
064 full load
064 part load
072 full load
072 part load
3.2
4.5
6.0
7.8
2.3
3.6
5.0
6.5
5.0
1.8
3.8
6.5
9.7
1.0
2.6
5.0
8.1
2.8
4.2
1.2
2.4
3.9
3.4
4.9
0.9
1.7
5.7
0.9
2.0
3.4
7.0
0.8
2.0
3.6
30°F
1.4
2.8
4.7
5.8
1.2
2.2
12
15
18
21
10
13
16
19
14
8
12
16
20
6
10
14
18
8
10
6
9
12
9
11
4
6
15
5
8
11
10
3
5
7
9
5
7
4
6
8
2.4
3.4
4.6
5.9
1.7
2.6
3.7
5.0
1/26/12
3.8
1.3
2.8
4.8
7.4
0.8
2.0
3.8
6.1
2.1
3.2
1.0
1.8
2.9
2.6
3.7
0.7
1.3
4.3
0.7
1.5
2.5
110°F
1.0
2.1
3.5
5.3
0.6
1.5
2.8
4.4
1.0
1.7
4.7
1.7
3.5
6.0
9.1
0.9
2.5
4.7
7.6
2.6
3.9
1.2
2.2
3.6
5.3
0.9
1.8
3.1
3.0
4.2
5.7
7.3
2.1
3.3
4.6
6.2
1.8
3.4
5.5
1.2
2.1
3.2
4.6
0.8
1.6
Pressure Drop (psi)
50°F 70°F 90°F
1.3
1.2
1.1
2.6
4.4
6.6
0.7
2.4
4.1
6.2
0.7
2.3
3.8
5.8
0.7
1.7
3.2
5.1
1.1
1.9
3.0
4.3
0.8
1.5
1.6
3.0
4.8
1.0
1.8
2.8
4
0.7
1.4
2.8
4.0
5.3
6.8
2.0
3.0
4.3
5.8
4.4
1.6
3.3
5.6
8.5
0.9
2.3
4.4
7.1
2.5
3.7
1.1
2.1
3.4
5
0.8
1.7
2.9
2.6
3.7
4.9
6.4
1.9
2.8
4.0
5.4
4.1
1.4
3.0
5.2
8.0
0.8
2.1
4.1
6.6
2.3
3.4
1.0
2.0
3.2
4.7
0.8
1.6
2.8
36
T1GX, T2GX SERIES SPECIFICATION CATALOG
Performance Data
Model 012 - Single Speed PSC (400 cfm)
EWT
°F
20
30
40
50
60
70
80
90
100
110
120
1.7
0.3
1.0
1.6
0.3
1.0
1.7
0.3
1.0
1.7
0.3
1.0
1.7
0.3
1.0
1.7
0.3
1.0
0.3
1.0
1.7
0.3
1.0
1.6
0.3
1.0
1.6
0.3
1.0
1.6
0.3
1.0
1.5
3.8
0.7
2.2
3.8
0.7
2.2
3.8
0.7
2.3
3.8
0.7
2.3
3.9
0.7
2.3
3.9
0.7
2.3
0.7
2.3
3.9
0.7
2.3
3.8
0.7
2.2
3.7
0.7
2.2
3.6
0.7
2.2
3.5
3.5
1.5
2.5
3.5
1.5
2.5
3.5
1.5
2.5
3.5
1.5
2.5
3.5
1.5
2.5
3.5
1.5
2.5
Flow
Rate
GPM
1.5
2.5
3.5
1.5
2.5
3.5
1.5
2.5
3.5
1.5
2.5
3.5
1.5
2.5
3.5
PSI
WPD
FT/HD
HC
MBtu/h
7.5
9.0
9.1
10.0
10.3
10.6
11.0
11.4
11.8
12.2
12.7
12.9
13.5
14.0
14.3
14.9
15.3
15.8
16.5
16.6
Heating - EAT 70 °F
Power kW
HE
MBtu/h
LAT
°F
Operation not recommended
0.86
0.86
0.87
0.88
0.88
0.89
0.90
0.90
0.91
0.92
0.78
4.8
85.3
Operation not recommended
0.80
6.3
88.8
0.81
6.3
89.1
Operation not recommended
0.82
7.2
91.1
0.83
0.83
0.83
0.84
0.85
0.85
7.4
7.8
8.2
8.5
8.9
9.3
91.7
92.5
93.5
94.4
95.2
96.3
9.8
10.0
10.5
11.0
11.3
11.9
12.2
12.8
13.4
13.5
97.4
98.0
99.2
100.4
101.2
102.6
103.4
104.7
106.3
106.4
Operation not recommended
COP
2.80
3.29
3.29
3.57
3.64
3.75
3.86
3.97
4.08
4.21
4.33
4.40
4.54
4.67
4.76
4.92
5.00
5.15
5.34
5.32
16.3
16.5
15.8
16.0
15.0
15.2
15.5
14.5
14.7
14.9
14.1
14.2
14.4
13.6
13.8
13.9
13.2
13.3
13.4
12.9
13.0
12.4
12.6
TC
MBtu/h
SC
MBtu/h
Cooling - EAT 80/67 °F
S/T
Ratio
Power kW
HR
MBtu/h
12.0
12.1
Operation not recommended
10.1
10.0
9.9
9.9
9.7
9.7
Operation not recommended
10.3
0.63
0.43
17.8
10.3
0.62
0.41
18.0
Operation not recommended
10.1
0.64
0.49
17.4
0.63
0.66
0.65
0.64
0.67
0.66
0.46
0.61
0.56
0.51
0.69
0.64
17.6
17.1
17.1
17.2
16.9
16.9
9.7
9.4
9.5
9.6
9.2
9.3
0.65
0.67
0.67
0.67
0.68
0.68
0.59
0.77
0.72
0.67
0.87
0.82
9.4
9.0
9.2
0.68
0.68
0.69
0.76
0.97
0.93
16.5
16.5
16.5
9.2
0.69
0.85
16.3
Operation not recommended
9.0
0.70
1.06
16.5
16.9
16.7
16.7
16.7
16.6
16.6
9.1
0.70
0.95
16.2
Operation not recommended
8.8
8.9
0.71
0.71
1.21
1.05
16.5
16.2
8.6
Operation not recommended
0.72
1.37
16.7
8.7
0.72
1.16
16.0
EER
37.7
40.2
31.9
34.9
24.6
27.3
30.6
21.1
23.1
25.3
18.3
19.8
21.4
15.7
16.8
18.2
13.6
14.2
15.7
12.1
13.7
10.3
12.0
8.8
10.5
10/1/10
37
T1GX, T2GX SERIES SPECIFICATION CATALOG
Performance Data cont.
Model 018 - Single Speed PSC (600 cfm)
EWT
°F
Flow
Rate
GPM
3.0
PSI
1.6
WPD
FT/HD
3.8
HC
MBtu/h
Power kW
Heating - EAT 70 °F
HE
MBtu/h
LAT
°F
COP
Operation not recommended
20 4.0
5.0
3.0
2.9
4.3
1.6
6.8
9.9
3.7
12.7
1.18
8.7
87.6
3.16
Operation not recommended
30 14.4
14.6
40
50
60
70
80
90
100
110
120
4.0
5.0
3.0
4.0
5.0
3.0
4.0
5.0
3.0
4.0
5.0
3.0
4.0
5.0
3.0
4.0
5.0
4.0
5.0
3.0
4.0
5.0
3.0
4.0
5.0
3.0
4.0
5.0
3.0
2.8
4.0
1.4
2.7
4.0
1.4
2.8
4.1
1.5
2.8
4.1
1.5
2.7
3.9
1.4
2.7
3.9
2.9
4.2
1.5
2.8
4.1
1.5
2.9
4.2
1.6
2.9
4.2
1.6
19.4
19.8
21.0
21.4
21.7
23.3
15.9
16.3
17.1
17.5
17.9
19.0
23.7
24.0
25.9
26.1
26.3
6.4
9.2
3.3
6.3
9.1
3.2
6.5
9.5
3.4
6.4
9.4
3.4
6.2
9.0
3.2
6.2
8.9
6.6
9.6
3.5
6.5
9.5
3.5
6.7
9.7
3.6
6.6
9.6
3.6
1.50
1.52
1.54
1.57
1.58
1.61
1.64
1.65
1.37
1.38
1.42
1.43
1.45
1.48
1.25
1.26
10.1
10.3
90.2
90.5
3.36
3.40
Operation not recommended
1.31
1.32
1.36
11.4
11.8
12.4
92.5
93.1
94.3
3.55
3.61
3.69
12.8
13.2
14.2
14.5
14.9
16.0
95.0
95.7
97.4
98.0
98.6
100.4
3.75
3.81
3.94
3.98
4.02
4.17
16.3
16.6
18.1
18.3
18.6
20.4
20.5
20.7
101.0
101.6
104.0
104.5
105.1
108.0
108.3
108.6
4.18
4.20
4.44
4.43
4.45
4.72
4.68
4.67
Operation not recommended
HWC
MBtu/h
TC
MBtu/h
SC
MBtu/h
Cooling - EAT 80/67 °F
S/T
Ratio
Power kW
HR
MBtu/h
EER
HWC
MBtu/h
1.4
1.5
1.5
19.5
18.8
19.4
19.6
18.3
18.4
18.5
17.5
19.9
19.8
20.1
20.4
20.7
19.2
17.5
17.7
16.7
16.6
16.8
1.9
2.0
2.1
2.1
2.2
2.4
1.6
1.6
1.7
1.7
1.8
1.9
2.4
2.5
2.8
2.8
2.8
15.8
15.8
15.0
14.7
14.3
13.7
Operation not recommended
12.9
12.4
12.6
12.6
12.1
12.1
12.1
11.6
13.0
12.7
13.2
13.1
13.1
12.6
11.6
11.8
11.1
11.2
11.4
10.7
11.0
10.3
10.7
9.9
10.2
Operation not recommended
0.66
0.66
0.76
0.74
22.1
21.4
Operation not recommended
0.65
0.64
0.65
0.64
0.63
0.66
0.81
0.75
0.95
0.86
0.77
1.00
22.7
22.3
23.3
23.3
23.3
22.6
0.65
0.64
0.66
0.66
0.66
0.66
0.94
0.88
1.05
1.02
0.99
1.11
22.6
22.6
21.9
21.9
21.9
21.3
0.67
0.67
0.66
1.12
1.12
1.17
21.3
21.5
20.7
0.67
0.68
1.22
1.24
20.8
21.1
Operation not recommended
0.68
0.70
1.34
1.37
20.4
20.4
Operation not recommended
0.69
0.73
1.46
1.50
20.0
19.8
Operation not recommended
0.70
0.75
1.60
1.66
19.7
19.4
25.8
25.4
20.6
22.3
17.4
18.0
18.6
15.8
24.7
26.2
21.3
23.8
27.0
19.2
15.6
15.8
14.3
13.6
13.6
11.8
11.5
10.3
9.8
8.9
8.3
--
--
1.1
1.0
1.3
1.3
1.2
1.7
--
--
0.9
0.9
0.9
1.1
1.6
1.5
2.2
2.0
1.9
2.5
2.3
3.2
3.0
4.0
3.6
10/1/10
38
T1GX, T2GX SERIES SPECIFICATION CATALOG
Performance Data cont.
Model 022 - Single Speed PSC (700 cfm)
EWT
°F
Flow
Rate
GPM
3.0
PSI
0.9
WPD
FT/HD
2.2
HC
Mbtu/h
Power kW
HEATING - EAT 70°F
HE
Mbtu/h
LAT
°F
COP
Operation not recommended
20 4.5
6.0
3.0
1.8
2.9
0.9
4.2
6.8
2.1
12.6
1.30
8.1
86.6
2.84
Operation not recommended
30 14.8
15.0
40
50
60
70
80
90
100
110
120
6.0
3.0
4.5
6.0
3.0
4.5
6.0
3.0
4.5
6.0
3.0
4.5
6.0
3.0
4.5
6.0
6.0
3.0
4.5
6.0
3.0
4.5
4.5
6.0
3.0
4.5
6.0
3.0
4.5
2.3
0.7
1.4
2.2
0.7
1.3
2.5
0.8
1.5
2.4
0.7
1.4
2.2
0.7
1.3
2.1
2.7
0.8
1.6
2.6
0.8
1.5
1.7
2.8
0.9
1.7
2.8
0.9
1.6
22.6
23.6
24.8
25.1
25.8
27.0
17.3
17.6
18.8
19.7
20.0
21.2
22.2
27.4
28.0
29.2
29.7
5.4
1.7
3.2
5.2
1.6
3.1
5.8
1.8
3.4
5.6
1.7
3.3
5.0
1.5
2.9
4.8
6.2
1.9
3.7
6.0
1.8
3.6
4.0
6.6
2.0
3.9
6.4
2.0
3.8
1.44
1.45
1.48
1.49
1.50
1.52
1.54
1.36
1.36
1.39
1.40
1.40
1.43
1.31
1.32
10.3
10.5
89.5
89.8
3.31
3.33
Operation not recommended
1.33
1.34
1.33
1.36
12.8
13.0
14.2
15.0
92.9
93.3
94.8
96.0
3.82
3.85
4.14
4.25
15.4
16.5
17.5
17.8
18.8
19.9
96.5
98.0
99.4
99.8
101.2
102.8
4.30
4.55
4.67
4.72
4.94
5.06
20.2
20.8
21.9
22.3
22.9
24.0
24.5
103.2
104.1
105.7
106.3
107.0
108.6
109.3
5.11
5.22
5.36
5.40
5.47
5.62
5.66
Operation not recommended
HWC
Mbtu/h
TC
Mbtu/h
SC
MBtu/h
COOLING - EAT 80/67 °F
S/T
Ratio
Power kW
HR
Mbtu/h
1.5
1.6
1.6
2.3
2.5
2.5
2.6
2.8
2.8
1.8
1.8
2.0
2.0
2.1
2.2
2.3
2.9
3.1
3.2
3.3
24.1
24.4
25.1
24.3
24.6
24.7
23.2
23.5
24.9
25.2
25.4
25.7
26.0
24.6
24.9
23.7
21.5
21.7
21.9
20.8
21.0
18.6
18.7
17.2
17.4
Operation not recommended
EER
HWC
MBtu/h
18.0
17.1
16.8
16.4
16.6
16.6
16.1
16.2
17.1
17.1
16.8
16.9
16.9
16.6
16.8
16.2
15.6
15.8
15.8
15.4
15.4
14.9
14.9
14.4
14.4
Operation not recommended
0.75
0.70
0.81
0.79
26.6
26.8
Operation not recommended
0.68
0.68
0.66
0.66
0.65
0.68
0.68
0.87
0.85
0.99
0.95
0.93
1.09
1.04
27.3
27.5
27.7
28.0
28.2
26.9
27.2
0.67
0.68
0.68
0.67
0.69
0.69
1.02
1.22
1.16
1.13
1.36
1.30
27.4
26.6
26.9
27.0
25.6
25.8
0.69
0.73
0.73
1.26
1.52
1.45
26.0
24.0
24.2
0.72
1.41
24.4
Operation not recommended
0.74
1.62
23.3
0.74
1.58
23.5
Operation not recommended
0.80
1.81
21.3
0.79
1.77
21.5
Operation not recommended
0.84
2.04
20.0
0.83
1.99
20.2
29.7
30.9
24.7
19.9
21.1
21.9
17.1
18.1
28.6
29.8
25.7
27.1
28.1
22.5
23.8
18.8
14.1
15.0
15.5
12.8
13.2
10.2
10.6
8.4
8.8
---
---
3.2
3.0
3.9
3.7
4.7
4.4
2/10/12
1.3
1.7
1.7
1.6
2.2
2.1
---
---
1.2
1.1
1.1
1.4
1.3
2.0
2.7
2.6
2.4
39
T1GX, T2GX SERIES SPECIFICATION CATALOG
Performance Data cont.
Model 030 - Single Speed PSC (900 cfm)
EWT
°F
Flow
Rate
GPM
4.0
PSI
1.4
WPD
FT/HD
3.5
HC
Mbtu/h
Power kW
HEATING - EAT 70°F
HE
Mbtu/h
LAT
°F
COP
Operation not recommended
20 6.0
8.0
4.0
2.8
4.6
1.4
7.2
12.1
3.4
17.6
1.67
11.9
88.1
3.09
Operation not recommended
30 20.2
20.7
40
50
60
70
80
90
100
110
120
8.0
4.0
6.0
8.0
4.0
6.0
8.0
4.0
6.0
8.0
4.0
6.0
8.0
4.0
6.0
8.0
8.0
4.0
6.0
8.0
4.0
6.0
6.0
8.0
4.0
6.0
8.0
4.0
6.0
3.6
11.1
2.1
3.5
1.0
2.0
3.9
1.2
2.3
3.8
1.1
2.2
3.4
1.0
2.0
3.2
4.2
1.2
2.4
3.9
1.2
2.4
2.7
4.4
1.3
2.6
4.3
1.3
2.5
30.7
32.4
33.5
34.1
35.1
36.4
23.7
24.2
25.9
26.8
27.4
29.1
30.1
36.9
37.9
39.3
39.9
9.6
2.7
5.5
9.3
2.6
5.3
10.4
2.9
5.9
10.0
2.8
5.7
11.1
3.1
6.4
10.7
3.0
6.2
7.0
11.8
3.3
6.8
11.4
3.2
6.6
8.9
2.5
5.1
8.6
1.90
1.93
1.95
1.98
2.01
2.04
2.06
1.76
1.80
1.81
1.82
1.87
1.88
1.66
1.68
14.6
14.9
90.8
91.2
3.57
3.61
Operation not recommended
1.70
1.72
1.74
1.75
17.9
18.3
20.0
20.8
94.4
94.9
96.6
97.6
4.07
4.12
4.36
4.49
21.3
23.0
23.9
24.5
26.0
27.1
98.1
99.9
101.0
101.6
103.3
104.5
4.55
4.75
4.89
4.93
5.08
5.22
27.6
28.5
29.7
30.2
31.0
32.3
32.8
105.1
106.1
107.4
108.0
108.9
110.4
111.0
5.24
5.32
5.46
5.48
5.51
5.64
5.66
Operation not recommended
HWC
Mbtu/h
TC
Mbtu/h
SC
MBtu/h
COOLING - EAT 80/67 °F
S/T
Ratio
Power kW
HR
Mbtu/h
2.0
2.2
2.2
3.1
3.3
3.4
3.5
3.7
3.8
2.4
2.5
2.6
2.7
2.8
3.0
3.0
3.9
4.2
4.3
4.4
26.4
26.9
30.4
30.1
30.2
30.6
28.9
29.0
28.7
29.1
30.7
30.8
31.2
30.0
30.0
29.3
26.7
26.9
27.1
25.6
25.9
21.7
22.0
21.0
21.3
Operation not recommended
EER
HWC
MBtu/h
18.9
18.8
21.5
21.7
21.7
21.8
21.4
21.4
20.4
20.3
21.8
21.9
21.9
21.4
21.5
21.5
20.2
20.2
20.3
20.2
20.3
18.9
19.0
18.3
18.3
Operation not recommended
0.71
0.70
1.06
1.03
30.0
30.4
Operation not recommended
0.71
0.70
0.71
0.71
0.70
0.72
0.71
1.14
1.11
1.29
1.25
1.22
1.40
1.35
32.6
32.9
35.1
35.0
35.3
34.7
34.7
0.71
0.72
0.72
0.71
0.74
0.74
1.32
1.54
1.49
1.46
1.70
1.64
34.9
35.4
35.3
35.5
34.7
34.6
0.73
0.76
0.75
1.61
1.87
1.80
34.8
33.1
33.0
0.75
1.77
33.2
Operation not recommended
0.79
2.01
32.5
0.78
1.97
32.6
Operation not recommended
0.87
2.22
29.3
0.87
2.17
29.4
Operation not recommended
0.87
2.47
29.5
0.86
2.42
29.5
24.9
26.1
22.9
19.5
20.3
20.9
17.0
17.7
25.1
26.1
23.8
24.7
25.5
21.4
22.2
18.2
14.3
14.9
15.3
12.8
13.1
9.8
10.1
8.5
8.8
---
---
4.1
3.9
5.0
4.7
6.0
5.7
2/10/12
1.6
2.2
2.1
2.0
2.8
2.7
---
---
1.5
1.4
1.4
1.8
1.7
2.5
3.5
3.3
3.2
40
T1GX, T2GX SERIES SPECIFICATION CATALOG
Performance Data cont.
Model 036 - Single Speed PSC (1250 cfm)
EWT
°F
Flow
Rate
GPM
5.0
PSI
1.0
WPD
FT/HD
2.4
HC
Mbtu/h
Power kW
HEATING - EAT 70°F
HE
Mbtu/h
LAT
°F
COP
Operation not recommended
20
30
7.0
9.0
5.0
7.0
2.1
3.6
1.0
2.1
4.9
8.2
2.3
4.7
21.8
24.5
1.99
15.0
86.1
3.21
Operation not recommended
1.99
17.7
88.1
3.60
25.0
40
50
60
70
80
90
100
110
120
9.0
5.0
7.0
9.0
5.0
7.0
9.0
5.0
7.0
9.0
9.0
5.0
7.0
9.0
5.0
7.0
9.0
5.0
7.0
9.0
5.0
7.0
9.0
5.0
7.0
9.0
5.0
7.0
2.8
0.8
1.6
2.7
0.8
1.6
2.6
0.7
1.5
2.5
3.0
0.9
1.7
2.9
0.8
1.7
3.3
0.9
1.9
3.1
0.9
1.8
3.5
1.0
2.0
3.4
1.0
1.9
28.4
29.0
30.9
32.0
32.6
34.7
35.9
36.6
38.6
40.0
40.7
41.8
43.4
44.1
45.3
47.0
47.7
6.6
1.8
3.8
6.3
1.8
3.6
6.1
1.7
3.5
5.8
7.0
2.0
4.0
6.8
1.9
3.9
7.5
2.1
4.3
7.3
2.1
4.2
8.0
2.3
4.6
7.8
2.2
4.5
2.20
2.20
2.23
2.25
2.25
2.28
2.31
2.10
2.11
2.12
2.15
2.16
2.18
2.01
18.1
88.5
3.64
Operation not recommended
2.04
21.5
91.1
4.09
2.06
2.07
2.08
22.0
23.8
24.9
91.5
92.9
93.7
4.14
4.37
4.51
25.5
27.5
28.6
29.2
31.3
32.6
94.2
95.7
96.6
97.1
98.6
99.6
4.56
4.81
4.95
4.99
5.24
5.38
33.2
34.3
35.8
36.4
37.6
39.2
39.8
100.1
101.0
102.1
102.6
103.5
104.8
105.3
5.41
5.57
5.71
5.73
5.89
6.03
6.05
Operation not recommended
HWC
Mbtu/h
TC
Mbtu/h
SC
MBtu/h
COOLING - EAT 80/67 °F
S/T
Ratio
Power kW
HR kBtuh
2.4
2.6
2.7
3.4
3.6
3.7
3.8
4.1
4.2
3.0
3.0
3.2
3.3
4.3
4.6
4.7
4.8
5.1
5.3
5.4
30.6
31.1
33.6
34.1
36.3
36.4
36.8
36.0
36.1
36.5
36.5
36.6
37.0
35.6
35.8
36.2
33.4
33.6
33.9
32.7
33.0
29.4
29.7
27.5
27.8
Operation not recommended
EER
HWC
MBtu/h
22.0
21.4
23.9
23.9
25.9
26.0
26.0
26.5
26.6
26.6
27.5
27.5
27.6
27.4
27.4
27.5
26.6
26.6
26.7
26.3
26.5
24.5
24.6
24.1
24.2
Operation not recommended
0.72
1.26
33.1
0.69
1.22
33.5
Operation not recommended
0.71
1.36
36.0
0.70
0.71
0.72
0.71
0.74
0.74
1.32
1.53
1.48
1.45
1.65
1.60
36.5
38.7
38.8
39.2
38.5
38.6
0.73
0.75
0.75
0.75
0.77
0.76
1.56
1.81
1.75
1.72
1.99
1.91
39.0
39.1
39.2
39.6
38.3
38.4
0.76
0.80
0.79
1.88
2.17
2.09
38.8
36.1
36.3
0.79
2.05
36.6
Operation not recommended
0.81
2.31
35.4
0.80
2.27
35.7
Operation not recommended
0.83
2.54
32.2
0.83
2.49
32.5
Operation not recommended
0.88
0.87
2.81
2.75
30.5
30.8
24.4
25.6
24.8
25.8
23.7
24.6
25.5
21.8
22.6
23.4
20.1
20.9
21.6
17.9
18.7
19.2
15.4
16.1
16.5
14.1
14.5
11.6
11.9
9.8
10.1
---
---
4.8
4.6
5.9
5.6
7.1
6.7
2/10/12
1.6
2.1
2.0
1.9
2.6
2.5
---
---
1.7
1.6
2.4
3.3
3.1
3.0
4.1
3.9
3.7
41
T1GX, T2GX SERIES SPECIFICATION CATALOG
Performance Data cont.
Model 042 - Single Speed PSC (1350 cfm)
EWT
°F
Flow
Rate
GPM
5.0
PSI
0.8
WPD
FT/HD
1.9
HC
Mbtu/h
Power kW
HEATING - EAT 70°F
HE
Mbtu/h
LAT
°F
COP
Operation not recommended
20 8.0
11.0
5.0
2.3
4.4
0.8
5.3
10.3
1.8
25.4
2.41
17.1
87.4
3.09
Operation not recommended
30 29.3
29.7
40
50
60
70
80
90
100
110
120
11.0
5.0
8.0
11.0
5.0
11.0
5.0
8.0
11.0
5.0
8.0
8.0
11.0
5.0
8.0
11.0
5.0
8.0
11.0
5.0
8.0
11.0
5.0
8.0
8.0
11.0
5.0
8.0
11.0
3.5
0.6
1.7
3.4
0.6
3.8
0.7
1.9
3.7
0.7
1.8
1.7
3.3
0.6
1.6
3.2
0.7
2.1
4.1
0.7
2.0
3.9
0.7
1.9
2.2
4.3
0.8
2.1
4.2
39.3
41.1
42.0
42.7
44.8
33.3
33.9
35.8
37.3
38.0
45.9
45.9
48.4
49.8
49.1
51.8
53.5
8.2
1.5
4.0
7.9
1.4
8.8
1.6
4.3
8.5
1.5
4.2
3.9
7.6
1.3
3.7
7.3
1.7
4.8
9.4
1.7
4.6
9.1
1.6
4.5
5.1
10.0
1.8
4.9
9.7
2.73
2.65
2.73
2.77
2.68
2.78
2.82
2.52
2.57
2.58
2.57
2.63
2.65
2.63
2.70
2.45
2.45
21.0
21.4
90.1
90.4
3.51
3.56
Operation not recommended
2.52
2.52
24.7
25.3
92.9
93.3
3.88
3.94
27.2
28.5
29.3
30.5
32.1
33.0
33.7
35.5
94.6
95.6
96.1
97.0
98.2
98.8
99.3
100.7
4.16
4.26
4.33
4.48
4.58
4.66
4.76
4.86
36.6
36.9
39.0
40.3
40.0
42.4
43.9
101.5
101.5
103.2
104.1
103.7
105.6
106.7
4.94
5.09
5.18
5.28
5.37
5.47
5.57
Operation not recommended
HWC
Mbtu/h
TC
Mbtu/h
SC
MBtu/h
COOLING - EAT 80/67 °F
S/T
Ratio
Power kW
HR kBtuh
3.7
3.9
4.0
5.3
5.4
5.6
6.0
6.1
4.3
4.4
4.7
4.8
5.0
6.3
6.7
6.9
7.1
7.5
7.8
8.0
41.0
41.4
43.1
43.6
44.1
43.1
43.8
42.7
43.1
43.3
43.8
44.2
44.3
41.4
42.1
42.6
39.0
39.8
40.2
38.2
38.6
34.6
35.0
32.5
32.8
Operation not recommended
EER
HWC
MBtu/h
28.4
27.8
31.4
31.7
31.7
32.4
32.8
29.7
29.7
30.7
31.0
31.0
32.8
31.7
32.0
32.0
30.8
31.1
31.1
30.5
30.5
28.2
28.2
27.9
27.9
Operation not recommended
0.69
0.67
1.73
1.69
43.4
43.7
Operation not recommended
0.70
0.69
1.81
1.77
45.1
45.5
0.71
0.71
0.70
0.73
0.73
0.72
0.75
0.75
2.01
1.93
1.88
2.17
2.08
2.03
2.37
2.26
45.7
46.2
46.6
45.6
46.1
46.5
45.7
46.4
0.74
0.77
0.76
0.75
0.79
0.78
2.21
2.59
2.47
2.41
2.86
2.72
46.8
44.0
44.7
45.1
41.7
42.5
0.77
2.64
42.9
Operation not recommended
0.80
2.98
40.9
0.79
2.91
41.3
Operation not recommended
0.82
0.81
3.29
3.20
37.4
37.7
Operation not recommended
0.86
0.85
3.61
3.52
35.4
35.7
23.8
24.6
19.8
20.9
21.7
18.2
19.4
23.5
24.4
21.6
22.7
23.5
20.1
15.9
17.0
17.7
13.7
14.7
15.2
12.8
13.3
10.5
10.9
9.0
9.3
---
---
7.5
7.2
9.2
8.8
11.1
10.6
2/10/12
3.2
3.0
2.9
4.0
3.8
---
---
2.6
2.5
2.4
3.6
5.1
4.8
4.6
6.4
6.1
5.8
42
T1GX, T2GX SERIES SPECIFICATION CATALOG
Performance Data cont.
Model 048 - Single Speed PSC (1500 cfm)
EWT
°F
Flow
Rate
GPM
6.0
PSI
1.1
WPD
FT/HD
2.6
HC
MBtu/h
Power kW
HEATING - EAT 70°F
HE
MBtu/h
LAT
°F
COP
Operation not recommended
20
30
9.0
12.0
6.0
9.0
2.3
4.0
1.1
2.3
5.4
9.2
2.5
5.3
32.8
37.5
3.05
22.4
90.2
3.15
Operation not recommended
3.13
26.8
93.1
3.51
38.0
40
50
60
70
80
90
100
110
120
12.0
6.0
9.0
12.0
6.0
9.0
12.0
6.0
9.0
12.0
6.0
9.0
12.0
6.0
9.0
12.0
12.0
6.0
9.0
12.0
6.0
9.0
12.0
6.0
9.0
12.0
6.0
9.0
3.2
0.9
1.8
3.1
0.8
1.7
3.0
0.8
1.7
2.8
3.4
0.9
1.9
3.3
0.9
1.9
3.7
1.0
2.1
3.5
1.0
2.0
3.9
1.1
2.2
3.8
1.0
2.1
43.0
43.8
46.2
48.1
49.0
50.8
53.1
54.4
55.5
58.2
59.7
59.4
62.5
64.3
63.2
66.8
68.9
7.4
2.0
4.2
7.1
1.9
4.0
6.8
1.8
3.8
6.6
7.9
2.1
4.5
7.6
2.1
4.3
8.4
2.3
4.8
8.2
2.2
4.6
9.0
2.5
5.1
8.7
2.4
4.9
3.54
3.46
3.58
3.62
3.52
3.66
3.71
3.33
3.33
3.41
3.43
3.41
3.51
3.13
27.3
93.5
3.56
Operation not recommended
3.23
32.0
96.6
3.90
3.24
3.26
3.32
32.7
35.1
36.7
97.0
98.5
99.7
3.96
4.16
4.25
37.7
39.5
41.5
42.7
43.9
46.3
100.3
101.4
102.8
103.6
104.3
105.9
4.31
4.48
4.57
4.64
4.78
4.87
47.7
47.5
50.3
51.9
51.2
54.3
56.2
106.9
106.6
108.6
109.7
109.0
111.2
112.5
4.95
5.03
5.11
5.20
5.26
5.35
5.44
Operation not recommended
HWC
MBtu/h
TC
MBtu/h
SC
MBtu/h
COOLING - EAT 80/67 °F
S/T
Ratio
Power kW
HR kBtuh
EER
HWC
MBtu/h
4.8
5.2
5.3
49.7
50.2
51.5
52.1
52.5
53.1
53.6
51.1
51.8
52.3
50.8
51.5
52.1
48.5
49.4
49.9
45.1
46.0
46.5
6.5
7.0
7.2
7.4
7.9
8.1
5.7
5.8
6.2
6.4
8.3
8.8
9.1
9.4
9.9
10.2
10.6
44.3
44.8
39.9
40.3
37.6
38.0
Operation not recommended
34.1
33.5
35.3
35.3
36.7
37.1
37.1
36.3
36.6
36.6
36.7
37.1
37.1
35.9
36.2
36.2
34.2
34.6
34.6
34.1
34.1
31.7
31.7
31.1
31.1
Operation not recommended
0.69
1.90
52.0
0.67
1.85
52.5
Operation not recommended
0.69
2.06
53.9
0.68
0.70
0.70
0.69
0.71
0.71
2.01
2.35
2.26
2.20
2.58
2.47
54.4
54.9
55.5
56.0
53.5
54.2
0.70
0.72
0.72
0.71
0.74
0.73
2.40
2.86
2.72
2.65
3.17
3.01
54.7
53.2
54.0
54.5
51.0
51.9
0.73
0.76
0.75
2.93
3.50
3.32
52.4
47.7
48.6
0.74
3.23
49.0
Operation not recommended
0.77
3.69
46.9
0.76
3.58
47.4
Operation not recommended
0.79
4.07
42.6
0.79
3.96
43.0
Operation not recommended
0.83
0.82
4.50
4.38
40.4
40.8
26.1
27.1
25.0
25.9
22.3
23.5
24.4
19.8
21.0
21.8
17.8
18.9
19.6
15.3
16.4
17.0
12.9
13.9
14.4
12.0
12.5
9.8
10.2
8.4
8.7
---
---
2.8
3.7
3.6
3.4
4.7
4.5
---
---
3.1
2.9
4.2
5.9
5.6
5.4
7.4
7.1
6.7
8.8
8.4
10.8
10.2
13.0
12.4
2/10/12
43
T1GX, T2GX SERIES SPECIFICATION CATALOG
Performance Data cont.
Model 060 - Single Speed PSC (2000 cfm)
EWT
°F
Flow
Rate
GPM
9.0
PSI
2.5
WPD
FT/HD
5.7
HC
Mbtu/h
Power kW
HEATING - EAT 70°F
HE
Mbtu/h
LAT
°F
COP
Operation not recommended
20 12.0
15.0
9.0
4.0
5.9
2.4
9.2
13.5
5.5
40.4
4.06
26.5
88.7
2.92
Operation not recommended
30 45.4
46.8
40
50
60
70
80
90
100
110
120
12.0
15.0
9.0
12.0
15.0
9.0
12.0
15.0
9.0
12.0
15.0
9.0
12.0
15.0
9.0
12.0
15.0
12.0
15.0
9.0
12.0
15.0
9.0
12.0
15.0
9.0
12.0
15.0
9.0
3.2
4.7
1.9
3.1
4.5
1.8
3.4
5.0
2.0
3.3
4.8
2.0
2.9
4.3
1.7
2.8
4.2
3.6
5.3
2.2
3.5
5.2
2.1
3.9
5.7
2.3
3.7
5.5
2.2
66.8
68.7
72.0
73.4
76.1
76.7
53.6
54.8
58.9
60.4
61.5
65.4
79.4
81.5
81.6
85.5
87.2
7.3
10.8
4.4
7.1
10.4
4.2
7.9
11.6
4.7
7.6
11.2
4.5
6.8
10.0
4.0
6.5
9.6
8.4
12.3
5.0
8.1
11.9
4.9
8.9
13.1
5.3
8.7
12.7
5.2
4.65
4.74
4.71
4.73
4.87
4.83
4.83
5.02
4.39
4.43
4.47
4.51
4.58
4.60
4.06
4.16
31.5
32.6
91.0
91.7
3.28
3.30
Operation not recommended
4.23
4.30
4.35
39.1
40.1
44.1
94.8
95.4
97.3
3.71
3.73
3.97
45.5
46.4
50.1
51.4
53.1
56.3
98.0
98.5
100.3
100.9
101.8
103.4
4.04
4.07
4.29
4.34
4.40
4.59
57.5
59.9
60.7
63.2
64.9
65.2
69.1
70.1
104.0
105.2
105.5
106.7
107.7
107.8
109.6
110.4
4.63
4.71
4.78
4.92
4.91
4.96
5.19
5.09
Operation not recommended
HWC
Mbtu/h
TC
Mbtu/h
SC
MBtu/h
COOLING - EAT 80/67 °F
S/T
Ratio
Power kW
HR kBtuh
5.8
6.2
6.4
8.7
8.9
9.5
9.8
10.0
10.7
6.9
7.1
7.5
7.7
7.9
8.4
11.0
11.3
12.0
12.4
12.8
68.8
70.0
69.4
69.8
67.8
68.5
68.5
64.8
70.3
71.1
71.4
71.4
72.2
69.1
65.4
65.8
60.3
61.0
61.6
58.5
59.1
53.4
54.0
49.8
50.7
Operation not recommended
EER
HWC
MBtu/h
47.6
48.1
49.6
49.9
49.4
49.4
49.9
48.0
49.8
49.6
50.5
51.0
51.0
49.4
48.0
48.5
45.8
45.8
46.3
45.0
45.5
41.8
42.3
41.5
41.9
Operation not recommended
0.69
0.69
2.91
2.74
71.2
72.3
Operation not recommended
0.71
0.70
0.71
0.71
0.71
0.71
3.10
2.95
3.44
3.38
3.23
3.63
72.7
73.5
73.8
73.9
74.6
71.5
0.71
0.71
0.73
0.72
0.73
0.74
3.53
3.41
3.97
3.83
3.73
4.35
71.9
72.2
70.3
71.0
71.0
67.3
0.73
0.74
0.76
4.16
4.05
4.74
67.9
68.3
62.9
0.75
0.75
4.49
4.37
63.5
64.1
Operation not recommended
0.77
0.77
4.99
4.87
61.1
61.7
Operation not recommended
0.78
0.78
5.43
5.30
56.1
56.6
Operation not recommended
0.83
0.83
6.09
5.92
52.6
53.5
23.7
25.6
19.7
20.5
17.1
17.9
18.4
14.9
22.7
24.1
20.8
21.1
22.3
19.0
15.7
16.2
12.7
13.6
14.1
11.7
12.1
9.8
10.2
8.2
8.6
---
---
11.8
11.2
14.5
13.8
17.5
16.7
2/10/12
4.8
4.6
6.3
6.0
5.7
8.0
---
---
4.1
3.9
3.7
5.0
7.6
7.2
10.0
9.5
9.1
44
T1GX, T2GX SERIES SPECIFICATION CATALOG
Performance Data cont.
Model 070 - Single Speed PSC (2200 cfm)
EWT
°F
Flow
Rate
GPM
12.0
PSI
3.0
WPD
FT/HD
7.0
HC
Mbtu/h
Power kW
HEATING - EAT 70°F
HE
Mbtu/h
LAT
°F
COP
Operation not recommended
20 15.0
18.0
12.0
4.4
6.0
3.0
10.2
13.9
6.8
46.9
4.62
31.2
89.8
2.98
Operation not recommended
30 54.1
54.3
40
50
60
70
80
90
100
110
120
15.0
18.0
12.0
15.0
18.0
12.0
15.0
18.0
12.0
15.0
18.0
12.0
15.0
18.0
12.0
15.0
18.0
15.0
18.0
12.0
15.0
18.0
12.0
15.0
18.0
12.0
15.0
18.0
12.0
3.5
4.8
2.3
3.4
4.6
2.2
3.8
5.1
2.5
3.6
5.0
2.4
3.3
4.4
2.2
3.1
4.3
4.0
5.5
2.7
3.9
5.3
2.6
4.3
5.8
2.9
4.1
5.7
2.8
79.3
80.3
85.1
88.2
89.4
91.0
63.1
63.5
69.5
70.9
71.6
77.1
95.1
96.8
97.3
102.5
104.5
8.1
11.1
5.4
7.8
10.7
5.2
8.7
11.9
5.8
8.4
11.5
5.6
7.5
10.2
5.0
7.2
9.8
9.3
12.7
6.2
9.0
12.3
6.0
9.9
13.5
6.6
9.6
13.1
6.4
5.39
5.43
5.46
5.56
5.60
5.62
5.75
5.80
5.04
5.06
5.15
5.21
5.24
5.31
4.73
4.75
37.9
38.1
92.8
92.8
3.35
3.35
Operation not recommended
4.89
4.91
5.00
46.4
46.7
52.4
96.5
96.7
99.3
3.78
3.79
4.07
53.7
54.3
59.5
61.6
62.4
66.9
99.9
100.1
102.4
103.4
103.8
105.8
4.13
4.14
4.39
4.47
4.49
4.69
69.8
70.9
72.3
76.2
77.6
78.1
82.9
84.7
107.1
107.6
108.3
110.0
110.7
110.9
113.1
114.0
4.79
4.83
4.89
5.01
5.06
5.07
5.23
5.28
Operation not recommended
HWC
Mbtu/h
TC
Mbtu/h
SC
MBtu/h
COOLING - EAT 80/67 °F
S/T
Ratio
Power kW
HR kBtuh
6.9
7.4
7.6
10.3
10.6
11.3
11.6
11.9
12.7
8.2
8.4
8.9
9.2
9.4
10.0
13.1
13.5
14.3
14.7
15.2
72.1
72.5
76.1
77.1
75.2
75.5
76.7
71.9
75.8
76.4
79.1
79.5
80.3
75.8
72.1
73.3
65.7
65.9
67.2
63.7
65.1
56.2
57.6
53.2
54.6
Operation not recommended
EER
HWC
MBtu/h
48.7
49.1
53.9
54.6
54.5
54.6
55.8
52.2
52.8
52.6
55.5
55.7
56.0
53.7
52.2
53.8
48.5
48.4
50.3
47.8
50.2
42.5
45.0
43.1
46.0
Operation not recommended
0.68
0.68
2.87
2.86
74.4
74.8
Operation not recommended
0.70
0.69
0.70
0.70
0.70
0.71
3.11
3.09
3.51
3.41
3.38
3.81
78.2
78.7
81.5
81.9
82.7
78.2
0.71
0.71
0.72
0.72
0.73
0.73
3.70
3.65
4.19
4.08
4.01
4.61
78.6
79.5
77.7
78.0
79.1
74.3
0.72
0.73
0.74
4.49
4.40
5.06
74.6
75.8
68.2
0.73
0.75
4.93
4.81
68.4
69.7
Operation not recommended
0.75
0.77
5.47
5.33
66.3
67.7
Operation not recommended
0.76
0.78
6.03
5.85
58.8
60.3
Operation not recommended
0.81
0.84
6.69
6.47
55.9
57.5
25.1
25.3
20.6
21.1
17.9
18.5
19.1
15.6
24.4
24.7
22.5
23.3
23.8
19.9
16.1
16.7
13.0
13.4
14.0
11.6
12.2
9.3
9.9
7.9
8.4
---
---
13.0
12.3
15.9
15.1
19.2
18.2
2/10/12
5.2
5.0
6.9
6.6
6.3
8.7
---
---
4.5
4.3
4.1
5.5
8.3
7.9
10.9
10.4
9.9
45
T1GX, T2GX SERIES SPECIFICATION CATALOG
Performance Data cont.
Model 018 - Single Speed ECM (600 cfm)
EWT
°F
Flow
Rate
GPM
3.0
WPD
PSI FT/HD
1.8
4.1
Airflow cfm
HC
MBtu/h
Heating - EAT 70°F
Power HE LAT kW MBtu/h °F
Operation not recommended
4.0
3.0
6.9
COP
20
5.0
3.0
4.3
1.7
9.9
3.9
500
600
12.3
12.7
1.09
1.12
8.6
8.9
90.8
87.6
Operation not recommended
3.30
3.34
30
4.0
5.0
3.0
4.2
6.8
9.7
500
600
500
600
40
50
60
70
80
90
3.0
4.0
5.0
3.0
4.0
5.0
3.0
4.0
5.0
3.0
4.0
5.0
3.0
4.0
5.0
3.0
4.0
5.0
1.7
2.9
4.2
1.6
2.9
4.2
1.6
2.8
4.1
1.5
2.8
4.1
1.5
2.8
4.1
1.4
2.7
4.0
3.8
6.7
9.6
3.7
6.6
9.6
3.6
6.6
9.5
3.5
6.5
9.5
3.4
6.4
9.4
3.2
6.3
9.2
500
600
500
600
500
600
500
600
600
500
600
500
600
500
600
500
600
500
600
500
600
500
600
500
600
500
500
600
500
600
500
600
500
600
1.45
1.48
1.48
1.51
1.49
1.52
1.52
1.55
1.37
1.36
1.39
1.39
1.42
1.41
1.44
1.43
1.46
1.55
1.58
1.55
1.59
22.6
23.3
22.9
23.6
23.3
24.0
25.1
25.8
19.4
19.2
19.8
20.4
21.0
20.7
21.4
21.0
21.7
25.3
26.1
25.5
26.3
16.6
17.1
17.0
17.5
17.4
17.9
18.5
19.1
18.8
13.9
14.4
14.2
14.6
1.16
1.19
1.17
1.20
10.0
10.3
10.2
10.5
93.8
90.2
94.2
90.5
3.51
3.55
3.54
3.58
15.4
Operation not recommended
1.22
11.2
96.5
3.70
15.9
15.8
16.3
1.24
1.23
1.26
11.6
11.6
12.0
92.5
97.2
93.1
3.74
3.76
3.79
1.27
1.30
1.28
1.31
1.29
1.32
1.33
1.36
1.34
12.3
12.7
12.6
13.0
13.0
13.4
13.9
14.4
14.3
98.7
94.4
99.4
95.0
100.2
95.6
102.2
97.4
102.9
3.83
3.87
3.89
3.93
3.95
3.99
4.08
4.12
4.11
14.8
14.6
15.1
15.6
16.2
15.9
16.5
16.2
16.7
17.7
18.3
17.9
18.5
18.2
18.8
19.9
20.6
20.0
20.7
20.2
20.9
109.9
104.0
110.4
104.5
111.1
105.0
114.4
107.9
98.0
103.6
98.6
105.7
100.4
106.4
100.9
107.0
101.5
114.9
108.3
115.2
108.6
4.57
4.62
4.55
4.60
4.58
4.63
4.85
4.90
4.16
4.15
4.19
4.31
4.35
4.32
4.36
4.33
4.37
4.79
4.84
4.81
4.86
3.0
1.4
3.1
4.0
2.7
6.2
100
5.0
3.0
4.0
4.0
1.3
2.7
9.1
3.0
6.1
110 Operation not recommended
5.0
3.0
4.0
3.9
1.3
2.6
9.0
2.9
6.1
120
5.0
3.9
8.9
HWC
MBtu/h
Airflow cfm
TC
MBtu/h
Cooling - EAT 80/67 °F
SC S/T Power HR
MBtu/h Ratio kW MBtu/h
1.6
1.5
17.2
17.7
16.2
16.7
16.2
16.6
16.3
16.8
18.3
17.9
18.4
18.0
18.5
17.0
17.5
17.0
17.5
20.1
20.7
18.7
19.2
18.9
19.4
19.1
19.6
17.8
19.4
20.0
19.2
19.8
19.6
20.1
19.8
20.4
500
600
500
600
500
600
500
600
600
500
600
500
600
500
600
500
600
500
600
500
600
500
600
500
600
500
500
600
500
600
500
600
500
600
3.0
2.8
3.1
2.9
2.7
2.5
3.0
2.8
2.7
2.5
2.7
2.4
2.2
2.4
2.2
2.4
2.2
2.0
2.2
2.0
2.4
1.9
1.9
2.1
2.0
2.1
1.9
1.7
1.9
1.8
1.8
1.6
1.8
1.7
1.6
1.6
1.7
1.6
500
600
500
600
500
600
500
600
500
600
500
600
500
600
500
600
19.0
19.5
18.3
18.8
15.3
15.8
15.3
15.8
14.6
15.0
14.3
14.7
13.8
14.2
13.3
13.7
Operation not recommended
0.66
0.61
0.66
0.60
0.65
0.61
0.66
0.61
0.66
0.59
0.63
0.61
0.66
0.60
0.65
0.59
0.64
0.61
12.1
10.9
12.1
10.9
12.1
10.4
11.6
10.4
11.6
11.8
13.1
11.4
12.7
11.4
12.6
11.3
12.6
10.9
Operation not recommended
11.6
12.9
11.2
12.4
0.61
0.66
0.61
0.66
0.65
0.70
0.63
0.68
21.2
21.9
20.4
21.1
Operation not recommended
11.7
0.60
0.69
21.8
13.0
11.5
12.8
0.65
0.60
0.65
0.75
0.64
0.69
22.5
21.4
22.1
11.9
13.2
11.8
13.2
0.61
0.66
0.60
0.64
0.82
0.89
0.74
0.80
22.4
23.1
22.4
23.1
0.99
0.89
0.96
0.86
0.93
0.97
1.04
0.97
1.05
0.66
0.71
0.87
0.94
0.81
0.88
0.76
0.82
0.92
21.7
20.9
21.7
20.9
21.7
20.3
21.0
20.3
21.1
22.4
23.1
21.6
22.4
21.7
22.4
21.7
22.4
20.9
10.6
11.8
10.0
11.1
0.62
0.67
0.62
0.67
0.95
1.02
1.02
1.10
20.4
21.1
19.7
20.4
10.0
11.1
10.3
11.4
0.62
0.67
0.63
0.68
1.07
1.15
1.04
1.12
19.8
20.5
19.9
20.6
Operation not recommended
9.6
10.7
9.9
11.1
0.63
0.68
0.65
0.70
1.17
1.26
1.19
1.28
19.3
20.1
19.4
20.1
Operation not recommended
9.2
0.63
1.28
19.0
10.2
9.6
10.7
0.68
0.67
0.73
1.38
1.33
1.44
19.7
18.9
19.6
Operation not recommended
8.8
0.64
1.41
18.6
9.8
9.2
0.69
0.69
1.51
1.48
19.4
18.4
10.2
0.74
1.60
19.1
EER
HWC
MBtu/h
29.4
28.1
29.1
27.9
18.1
17.3
15.9
15.2
15.1
14.5
15.7
15.0
18.6
20.2
19.3
20.9
20.0
17.6
16.8
17.5
16.7
30.7
29.4
21.5
20.5
23.2
22.2
25.2
24.0
19.4
28.0
26.8
29.9
28.6
23.8
22.7
26.8
25.7
13.1
12.5
12.9
12.3
11.4
10.9
10.7
10.2
9.8
9.4
9.0
8.6
2.9
3.2
2.6
3.0
2.2
2.4
2.0
2.3
--
--
--
--
3.5
4.0
3.1
3.5
10/1/10
1.8
2.0
1.7
1.9
1.4
1.5
1.9
2.1
1.6
1.7
1.5
1.6
1.3
1.1
1.3
1.1
1.2
1.1
0.9
1.0
1.2
0.8
0.9
1.0
1.1
1.0
0.9
1.0
0.8
0.9
--
--
--
--
46
T1GX, T2GX SERIES SPECIFICATION CATALOG
Performance Data cont.
Model 022 - Single Speed ECM or 5-Speed ECM (700 cfm)
EWT
°F
20
Flow
Rate
GPM
3.0
4.5
PSI FT/HD
0.9
1.8
WPD
2.2
4.2
Airflow
CFM
HC
MBtu/h
HEATING - EAT 70°F
Power kW
HE
MBtu/h
LAT
°F
Operation not recommended
COP
HWC
Mbtu/h
Airflow
CFM
TC
Mbtu/h
30
40
50
60
70
80
90
6.0
3.0
4.5
6.0
3.0
4.5
6.0
3.0
4.5
6.0
3.0
4.5
6.0
3.0
4.5
6.0
3.0
4.5
6.0
3.0
4.5
6.0
2.9
0.9
1.7
2.8
0.9
1.7
2.8
0.9
1.6
2.7
0.8
1.6
2.6
0.8
1.5
2.5
0.8
1.5
2.4
0.7
1.4
2.3
6.8
2.1
4.0
6.6
2.0
3.9
6.4
2.0
3.8
6.2
1.9
3.7
6.0
1.8
3.6
5.8
1.8
3.4
5.6
1.7
3.3
5.4
600
700
600
700
600
700
600
700
600
700
600
700
600
700
600
700
700
600
700
600
700
600
700
600
700
700
600
700
600
700
600
700
600
600
700
600
700
600
700
600
25.7
26.5
26.1
27.0
26.6
27.5
27.8
28.8
28.2
29.3
1.27
1.30
1.27
1.32
1.30
1.34
1.31
1.35
1.32
1.23
1.24
1.23
1.25
1.23
1.27
1.26
1.29
22.1
22.6
23.2
23.6
24.3
24.1
24.7
24.6
25.3
19.2
19.1
19.6
20.3
20.7
21.2
21.8
21.6
12.0
1.16
8.0
88.4
3.03
12.1
1.17
8.1
86.0
Operation not recommended
3.04
14.0
14.3
14.3
1.17
1.18
1.18
10.0
10.3
10.3
91.6
88.9
92.1
3.53
3.57
3.57
14.5
1.19
10.5
89.2
Operation not recommended
3.59
16.5
16.9
1.19
1.20
12.5
12.8
95.5
92.3
4.06
4.12
16.8
17.1
18.0
18.3
18.9
1.21
1.21
1.20
1.20
1.23
12.7
13.0
13.9
14.2
14.7
96.0
92.7
97.7
94.2
99.1
4.08
4.16
4.39
4.48
4.51
1.38
1.35
1.40
1.36
1.41
1.37
1.44
1.39
1.46
1.41
15.0
14.9
15.4
16.0
16.5
16.9
17.5
17.2
17.8
18.2
18.8
19.1
19.9
19.5
20.2
20.0
20.8
21.0
21.9
21.4
22.3
21.8
22.9
22.9
24.0
23.2
24.5
109.6
105.1
110.3
105.7
111.1
106.4
112.9
108.0
113.6
108.7
5.45
5.78
5.48
5.82
5.53
5.90
5.64
6.05
5.66
6.09
99.3
104.9
100.6
106.4
102.2
107.1
102.7
108.0
103.5
95.4
99.5
95.9
101.3
97.4
102.7
98.8
103.3
5.10
5.11
5.34
5.23
5.46
5.27
5.51
5.34
5.64
4.60
4.51
4.65
4.77
4.93
4.89
5.05
4.91
1.6
1.5
1.7
1.6
1.8
1.6
600
700
600
700
23.4
23.8
23.6
24.1
3.1
3.4
3.2
3.5
3.1
2.8
3.2
2.9
3.3
3.3
2.8
2.6
3.0
2.8
2.3
2.7
2.5
2.7
2.5
2.2
2.4
2.3
2.5
2.0
2.2
2.1
2.4
1.9
1.8
2.0
1.8
2.1
2.0
2.2
600
700
600
700
600
700
600
700
600
700
700
600
700
600
700
600
700
600
700
700
600
700
600
700
600
700
600
600
700
600
700
600
700
600
23.4
24.0
23.7
24.2
21.5
22.0
21.7
22.2
22.0
22.4
25.6
24.3
24.7
24.5
25.0
24.7
25.2
23.2
23.7
26.2
25.9
26.4
24.6
25.1
24.8
25.3
25.1
24.9
25.4
25.1
25.7
25.4
25.9
25.6
3.0
0.7
1.7
100
4.5
6.0
1.4
2.2
3.2
5.2
600
700
600
700
20.8
21.2
21.0
21.4
3.0
0.7
1.6
110
4.5
6.0
1.3
2.2
3.1
5.0
Operation not recommended
600
700
600
700
18.6
19.0
18.8
19.2
3.0
0.7
1.5
120
4.5
6.0
1.3
2.1
2.9
4.8
600
700
600
700
17.3
17.6
17.5
17.9
COOLING - EAT 80/67 °F
SC
Mbtu/h
S/T
Ratio
Power kW
HR
Mbtu/h
Operation not recommended
0.64
0.69
0.66
0.71
0.66
0.71
0.66
0.70
0.70
0.69
0.65
0.69
0.64
0.68
0.65
0.69
0.65
0.69
15.9
17.3
15.4
16.7
15.6
16.9
15.6
16.9
15.0
17.3
16.1
17.5
16.1
17.5
15.8
17.1
15.9
17.3
16.3
17.8
16.0
17.5
16.2
17.7
16.2
17.7
15.9
Operation not recommended
15.8
0.68
0.66
25.7
17.3
15.8
0.73
0.67
0.69
0.64
26.2
25.7
17.3
0.72
0.67
26.4
Operation not recommended
16.3
17.8
0.65
0.70
0.71
0.74
27.3
27.9
0.65
0.69
0.63
0.67
0.63
0.67
0.63
0.67
0.65
0.68
0.72
0.83
0.86
0.79
0.82
0.76
0.79
0.93
27.5
28.1
28.2
28.8
28.3
29.0
28.5
29.2
27.7
0.97
1.00
1.19
1.23
1.13
1.16
1.09
1.13
1.35
0.96
0.88
0.91
0.85
0.89
1.05
1.09
0.99
1.03
28.0
28.6
27.3
27.9
27.3
27.9
27.4
28.0
26.1
28.4
27.8
28.5
28.0
28.6
27.8
28.5
27.8
28.6
16.3
15.2
16.5
15.2
0.74
0.70
0.74
0.69
1.39
1.28
1.32
1.24
26.8
26.1
26.7
26.2
16.5
0.74
1.28
26.8
Operation not recommended
14.8
16.1
14.8
0.71
0.76
0.70
1.45
1.49
1.41
25.7
26.3
25.8
16.1
0.75
1.45
26.4
Operation not recommended
14.3
15.5
0.76
0.81
1.63
1.68
24.2
24.8
14.3
15.5
0.76
0.81
1.59
1.63
24.2
24.8
Operation not recommended
13.8
0.79
1.86
23.7
14.9
13.8
14.9
0.85
0.79
0.84
1.91
1.80
1.86
24.2
23.6
24.2
EER
HWC
Mbtu/h
35.6
34.4
36.9
36.0
20.8
20.6
21.7
21.4
15.9
15.8
17.0
16.9
17.8
17.5
28.9
23.1
22.7
24.6
24.2
25.6
25.2
19.5
19.2
31.9
34.0
33.3
26.5
26.0
28.3
27.7
29.4
35.3
34.3
36.7
35.9
30.7
30.1
32.6
14.3
14.2
15.0
14.8
11.4
11.3
11.9
11.8
9.3
9.3
9.7
9.6
2.9
3.2
2.7
3.0
---
---
---
---
3.6
3.9
3.3
3.7
4.3
4.7
4.0
4.4
2/13/12
2.7
2.4
2.6
2.2
1.9
2.1
1.8
2.0
2.5
2.4
1.4
1.6
2.0
2.2
1.3
1.6
1.7
1.5
1.7
1.4
1.2
1.3
1.1
1.1
1.0
1.1
1.3
---
---
---
---
1.1
1.2
1.0
47
T1GX, T2GX SERIES SPECIFICATION CATALOG
Performance Data cont.
Model 030 - Single Speed ECM or 5-Speed ECM (900 cfm)
EWT
°F
Flow
Rate
GPM
WPD
PSI FT/HD
Airflow
CFM
HC
MBtu/h
HEATING - EAT 70°F
Power kW
HE
MBtu/h
LAT
°F
COP
HWC
Mbtu/h
Airflow
CFM
TC
Mbtu/h
4.0
6.0
1.4
2.8
3.5
7.2
20
Operation not recommended
30
40
50
60
70
80
90
8.0
4.0
6.0
8.0
4.0
6.0
8.0
4.0
6.0
8.0
4.0
6.0
8.0
4.0
6.0
8.0
4.0
6.0
8.0
4.0
6.0
8.0
4.6
1.4
2.7
4.4
1.3
2.6
4.3
1.3
2.5
4.2
1.2
2.4
4.0
1.2
2.4
3.9
1.2
2.3
3.8
1.1
2.2
3.6
12.1
3.4
7.0
11.8
3.3
6.8
11.4
3.2
6.6
11.1
3.1
6.4
10.7
3.0
6.2
10.4
2.9
5.9
10.0
2.8
5.7
9.6
700
900
700
900
700
900
700
900
700
900
700
900
700
900
700
900
900
700
900
700
900
700
900
700
900
700
900
700
900
700
900
700
900
700
900
700
900
700
900
700
1.76
1.81
1.78
1.84
1.81
1.87
1.83
1.89
1.85
1.94
1.67
1.67
1.69
1.69
1.71
1.70
1.76
1.75
1.78
1.89
1.97
1.92
2.00
1.94
33.1
32.7
33.7
33.6
34.7
34.8
36.0
35.3
36.5
36.2
27.9
28.7
28.9
29.7
29.5
30.3
31.1
32.0
32.1
37.4
37.5
38.9
38.0
39.5
22.7
23.3
23.3
23.8
24.9
25.5
25.7
26.4
26.3
26.9
16.9
17.2
1.52
1.55
11.7
11.9
92.4
87.7
Operation not recommended
3.26
3.25
19.4
19.8
19.9
20.2
1.51
1.54
1.53
1.56
14.2
14.6
14.7
14.9
95.7
90.4
96.3
90.8
Operation not recommended
3.77
3.77
3.82
3.81
1.56
1.58
1.58
1.60
1.60
1.62
1.61
1.63
1.63
1.64
17.4
17.9
17.9
18.3
19.4
20.0
20.2
20.8
20.7
21.3
100.1
93.9
100.8
94.5
102.9
96.2
104.0
97.1
104.8
97.7
4.27
4.31
4.32
4.36
4.55
4.61
4.68
4.75
4.72
4.81
22.2
23.0
23.1
23.9
23.6
24.5
25.1
26.0
26.0
27.1
26.5
27.6
27.3
28.5
28.4
29.7
28.9
30.2
29.6
31.0
30.8
32.3
31.2
32.8
104.1
113.2
104.6
114.4
105.7
116.0
107.0
116.7
107.6
117.8
107.0
99.5
108.2
100.6
109.0
101.1
111.1
102.9
112.5
108.5
119.6
110.0
120.3
110.6
5.50
5.31
5.53
5.36
5.61
5.46
5.75
5.47
5.77
5.47
4.90
5.02
5.01
5.16
5.05
5.21
5.19
5.36
5.28
5.80
5.59
5.93
5.58
5.95
2.2
2.0
2.4
2.2
2.4
2.2
700
900
700
900
26.1
26.8
26.3
27.3
4.1
3.8
4.3
3.9
4.5
3.4
3.8
3.5
4.0
3.7
4.2
4.6
4.3
4.8
4.4
3.1
3.6
3.3
3.7
3.2
3.0
3.3
3.0
3.4
2.6
2.9
2.7
3.0
2.8
2.6
2.4
2.7
2.5
2.8
700
900
700
900
700
900
700
900
700
900
900
700
900
700
900
700
900
700
900
700
900
700
900
700
900
700
900
700
900
700
900
700
900
700
30.6
30.1
31.0
28.4
29.3
28.6
29.4
28.8
29.7
26.3
27.1
26.5
27.3
26.7
27.6
29.5
30.4
29.6
30.5
29.9
30.8
29.7
30.6
29.7
28.3
29.1
28.5
29.5
30.2
31.1
30.3
31.2
30.6
31.6
4.0
1.1
2.7
100
6.0
8.0
2.1
3.5
5.5
9.3
700
900
700
900
25.3
26.0
25.5
26.3
4.0
1.0
2.6
110
6.0
8.0
2.0
3.4
5.3
8.9
Operation not recommended
700
900
700
900
21.5
22.2
21.7
22.4
4.0
1.0
2.5
120
6.0
8.0
2.0
3.2
5.1
8.6
700
900
700
900
20.8
21.4
20.9
21.7
COOLING - EAT 80/67 °F
SC
Mbtu/h
S/T
Ratio
Power kW
HR
Mbtu/h
Operation not recommended
0.70
0.64
0.70
0.67
0.73
0.67
0.72
0.66
0.72
0.68
0.64
0.70
0.65
0.70
0.64
0.69
0.65
0.71
0.65
21.6
19.3
21.7
19.0
21.3
19.1
21.3
19.1
21.4
18.0
18.9
21.3
19.1
21.3
19.1
21.4
19.2
21.6
19.3
18.0
20.2
18.0
20.2
19.3
21.7
19.5
21.8
19.5
21.8
Operation not recommended
16.7
18.7
16.7
18.7
0.64
0.70
0.63
0.68
0.87
0.94
0.85
0.91
29.1
30.0
29.2
30.4
Operation not recommended
0.64
0.70
0.63
0.68
0.64
0.70
0.64
0.70
0.64
0.69
0.95
1.02
0.93
0.99
1.10
1.17
1.06
1.13
1.04
1.10
31.5
32.6
31.7
32.9
34.0
35.1
33.9
35.0
34.1
35.3
1.37
1.27
1.34
1.51
1.58
1.45
1.52
1.42
1.49
1.68
1.21
1.28
1.16
1.23
1.14
1.20
1.35
1.42
1.30
35.3
34.4
35.5
33.6
34.7
33.5
34.6
33.7
34.8
32.0
33.6
34.7
33.5
34.7
33.8
34.9
34.3
35.4
34.2
20.1
18.0
20.1
18.1
20.2
0.74
0.68
0.74
0.68
0.73
1.75
1.62
1.68
1.58
1.65
33.1
32.0
33.0
32.1
33.2
Operation not recommended
18.0
0.71
1.83
31.5
20.1
18.1
20.2
0.77
0.71
0.77
1.89
1.79
1.85
32.5
31.6
32.6
Operation not recommended
16.9
0.79
2.04
28.5
18.8
17.0
0.85
0.78
2.10
1.99
29.3
28.5
18.9
0.84
2.05
29.4
Operation not recommended
16.3
18.1
16.4
0.78
0.85
0.78
2.30
2.35
2.25
28.7
29.5
28.6
18.2
0.84
2.30
29.5
EER
HWC
Mbtu/h
30.0
28.5
30.8
30.0
22.4
23.6
23.1
18.9
18.5
19.7
19.4
20.3
19.9
15.6
15.5
16.4
16.2
16.9
16.7
24.4
23.7
25.4
24.7
26.2
25.6
22.0
21.5
22.9
29.7
28.4
30.5
29.7
27.5
26.6
28.6
27.7
29.5
28.7
13.8
13.8
14.3
14.2
10.6
10.6
10.9
10.9
9.1
9.1
9.3
9.4
4.6
5.0
4.3
4.7
3.8
4.1
3.5
3.9
---
---
---
---
5.5
6.0
5.1
5.7
2/10/12
2.5
2.7
2.3
2.5
3.3
2.1
1.8
2.0
2.6
2.8
3.5
3.1
3.3
2.8
3.2
1.6
2.1
2.2
2.0
1.7
1.8
1.6
1.7
1.5
1.5
1.3
1.4
1.2
1.4
---
---
---
---
1.4
48
T1GX, T2GX SERIES SPECIFICATION CATALOG
Performance Data cont.
Model 036 - Single Speed ECM or 5-Speed ECM (1250 cfm)
EWT
°F
Flow
Rate
GPM
WPD
PSI FT/HD
Airflow
CFM
HC
MBtu/h
HEATING - EAT 70°F
Power kW
HE
MBtu/h
LAT
°F
COP
HWC
Mbtu/h
Airflow
CFM
TC
Mbtu/h
5.0
7.0
1.0
2.1
2.4
4.9
20
Operation not recommended
30
40
50
60
70
80
90
9.0
5.0
7.0
9.0
5.0
7.0
9.0
5.0
7.0
9.0
5.0
7.0
9.0
5.0
7.0
9.0
5.0
7.0
9.0
5.0
7.0
9.0
3.6
1.0
2.1
3.5
1.0
2.0
3.4
1.0
1.9
3.3
0.9
1.9
3.1
0.9
1.8
3.0
0.9
1.7
2.9
0.8
1.7
2.8
8.2
2.3
4.7
8.0
2.3
4.6
7.8
2.2
4.5
7.5
2.1
4.3
7.3
2.1
4.2
7.0
2.0
4.0
6.8
1.9
3.9
6.6
1050
1250
1050
1250
1050
1250
1050
1250
1050
1250
1050
1250
1050
1250
1050
1250
1050
1250
1050
1250
1050
1250
1050
1250
1050
1250
1050
1250
1050
1250
1050
1250
1050
1250
1050
1250
1050
1250
1050
1250
40.1
41.4
41.6
43.0
42.2
43.7
43.3
44.9
45.0
46.6
45.5
47.3
28.0
28.0
28.6
29.8
30.5
30.8
31.6
31.5
32.2
33.4
34.3
34.5
35.5
35.2
36.2
37.1
38.2
38.4
39.6
39.1
40.3
21.0
21.4
1.83
1.87
14.8
15.0
88.5
85.8
3.36
3.35
23.6
Operation not recommended
1.84
17.3
90.8
3.76
24.1
24.2
1.88
1.86
17.7
17.9
87.8
91.3
3.76
3.82
24.6
1.89
18.1
88.2
Operation not recommended
3.81
27.4
1.89
20.9
94.2
4.24
1.92
1.92
1.94
1.94
1.95
1.94
1.96
1.97
1.98
1.99
1.99
2.01
2.01
2.04
2.03
2.05
2.04
2.09
2.06
2.11
2.09
21.5
21.5
22.0
23.2
23.8
24.2
24.9
24.7
25.5
26.6
27.5
27.6
28.6
28.2
29.2
30.1
31.3
31.3
32.6
31.9
33.2
90.8
94.7
91.2
96.3
92.6
97.1
93.4
97.7
93.9
99.4
95.4
100.4
96.3
101.0
96.8
102.8
98.3
103.9
99.3
104.5
99.8
5.03
5.18
5.06
5.23
5.31
5.48
5.40
5.63
5.43
5.66
4.28
4.29
4.33
4.52
4.58
4.64
4.72
4.68
4.78
4.92
5.04
2.11
2.08
2.15
2.11
2.18
2.13
2.18
2.13
2.22
2.17
2.25
2.19
32.9
34.3
34.3
35.8
34.8
36.4
35.9
37.6
37.4
39.2
37.9
39.8
105.4
100.7
106.7
101.8
107.2
102.3
108.2
103.2
109.6
104.5
110.2
105.0
5.57
5.83
5.68
5.97
5.69
6.00
5.82
6.16
5.95
6.31
5.93
6.32
2.7
2.4
2.9
2.6
3.0
2.7
1050
1250
1050
1250
30.2
31.0
30.4
31.5
4.8
5.5
5.1
5.7
5.3
5.9
4.9
4.6
5.1
4.7
5.2
5.4
4.1
4.5
4.2
4.7
4.3
4.0
3.7
4.2
3.8
4.4
3.2
3.0
3.3
3.0
3.5
3.2
3.6
3.3
3.7
3.4
3.9
3.6
1050
1250
1050
1250
1050
1250
1050
1250
1050
1250
1050
1250
1050
1250
1050
1250
1050
1250
1050
1250
1050
1250
1050
1250
1050
1250
1050
1250
1050
1250
1050
1250
1050
1250
35.0
36.0
35.1
36.2
35.5
36.6
32.8
33.8
33.0
34.0
33.3
34.3
35.4
36.5
35.8
36.9
35.9
36.9
36.0
37.0
36.3
37.4
33.1
34.0
33.4
34.5
35.6
36.7
35.7
36.8
36.1
37.2
35.4
36.4
5.0
0.8
1.8
100
7.0
9.0
1.6
2.7
3.8
6.3
1050
1250
1050
1250
32.1
33.1
32.4
33.4
5.0
0.8
1.8
110
7.0
9.0
1.6
2.6
3.6
6.1
Operation not recommended
1050
1250
1050
1250
28.9
29.8
29.1
30.1
5.0
0.7
1.7
120
7.0
9.0
1.5
2.5
3.5
5.8
1050
1250
1050
1250
27.1
27.9
27.3
28.2
COOLING - EAT 80/67 °F
SC
Mbtu/h
S/T
Ratio
Power kW
HR
Mbtu/h
Operation not recommended
24.3
21.6
24.3
23.4
26.3
23.6
26.4
23.6
26.4
24.0
26.9
24.1
27.0
24.1
27.0
24.9
28.0
25.0
28.0
25.0
28.1
Operation not recommended
19.5
0.65
1.05
33.8
21.9
19.4
0.70
0.64
1.14
1.04
34.9
34.0
21.8
0.69
1.10
35.3
Operation not recommended
21.7
0.66
1.15
37.0
0.71
0.65
0.70
0.66
0.72
0.66
0.72
0.65
0.71
0.68
0.74
0.68
0.74
0.67
0.73
0.69
0.76
0.70
0.76
0.69
0.75
1.24
1.13
1.20
1.33
1.41
1.28
1.36
1.25
1.33
1.45
1.54
1.40
1.48
1.37
1.45
1.61
1.70
1.55
1.63
1.52
1.60
40.2
41.6
40.5
41.9
41.3
42.7
41.2
42.6
41.5
42.9
38.3
37.2
38.6
40.2
41.5
40.1
41.4
40.4
41.8
40.3
41.7
24.8
27.8
24.9
27.8
24.9
27.9
24.2
27.0
24.2
27.0
24.3
0.71
0.77
0.71
0.77
0.70
0.76
0.74
0.80
0.73
0.79
0.73
1.78
1.87
1.72
1.80
1.68
1.76
1.97
2.05
1.90
1.97
1.85
27.1
0.79
1.94
40.9
Operation not recommended
24.0
26.8
24.1
0.75
0.81
0.75
2.12
2.20
2.08
39.3
40.6
39.4
26.9
0.81
2.15
40.7
Operation not recommended
22.3
24.9
22.4
0.77
0.84
0.77
2.35
2.42
2.30
36.9
38.0
37.0
25.0
0.83
2.37
38.2
Operation not recommended
22.0
24.5
22.2
0.81
0.88
0.81
2.63
2.70
2.57
36.1
37.1
36.1
24.6
0.87
2.63
37.2
41.0
42.4
41.0
42.3
41.2
42.6
39.5
40.8
39.5
40.7
39.6
EER
HWC
Mbtu/h
28.6
27.2
29.4
28.7
19.6
19.3
20.4
20.2
21.1
20.7
16.6
16.5
17.4
17.3
17.9
17.7
25.4
24.7
26.2
25.6
22.3
21.8
23.2
22.7
24.0
23.4
28.7
27.5
29.5
28.7
26.8
26.0
27.9
27.0
28.8
28.0
24.4
23.7
15.1
15.0
15.6
15.5
12.3
12.3
12.7
12.7
10.3
10.4
10.6
10.7
5.4
5.9
5.0
5.6
4.5
4.8
4.1
4.6
---
---
---
---
6.5
7.1
6.1
6.7
2/10/12
3.0
3.9
4.1
3.6
3.9
3.4
3.1
3.3
2.9
3.1
2.7
3.7
2.6
2.3
2.5
2.2
2.4
1.9
2.0
1.7
1.9
2.5
---
---
---
---
1.7
1.8
1.6
1.7
1.4
1.6
2.0
2.1
49
T1GX, T2GX SERIES SPECIFICATION CATALOG
Performance Data cont.
Model 042 - Single Speed ECM or 5-Speed ECM (1350 cfm)
EWT
°F
Flow
Rate
GPM
WPD
PSI FT/HD
Airflow
CFM
HC
MBtu/h
HEATING - EAT 70°F
Power kW
HE
MBtu/h
LAT
°F
COP
HWC
Mbtu/h
Airflow
CFM
TC
Mbtu/h
5.0
8.0
0.8
2.3
1.9
5.3
20
Operation not recommended
30
40
50
60
70
80
90
11.0
5.0
8.0
11.0
5.0
8.0
11.0
5.0
8.0
11.0
5.0
8.0
11.0
5.0
8.0
11.0
5.0
8.0
11.0
5.0
8.0
11.0
4.4
0.8
2.2
4.3
0.8
2.1
4.2
0.7
2.1
4.1
0.7
2.0
3.9
0.7
1.9
3.8
0.7
1.9
3.7
0.7
1.8
3.5
10.3
1.8
5.1
10.0
1.8
4.9
9.7
1.7
4.8
9.4
1.7
4.6
9.1
1.6
4.5
8.8
1.6
4.3
8.5
1.5
4.2
8.2
1150
1350
1150
1350
1150
1350
1350
1150
1350
1150
1350
1150
1350
1150
1350
1150
1350
1150
1350
1150
1350
1150
1350
1150
1350
1150
1350
1150
1350
1150
1150
1350
1150
1350
1150
1350
1150
1350
1150
1350
2.39
2.51
2.42
2.44
2.34
2.54
2.42
2.57
2.46
2.48
2.32
2.26
2.39
2.32
2.41
2.34
2.40
2.32
2.48
2.37
2.60
2.47
2.64
2.51
43.7
43.8
44.9
43.7
44.9
46.0
47.3
47.3
48.7
46.7
37.5
38.3
39.2
40.0
40.1
41.0
40.7
41.6
42.7
48.0
49.2
50.8
50.8
52.4
31.8
32.3
32.4
32.9
34.2
34.8
35.6
36.2
36.3
37.0
24.0
24.3
2.12
2.10
16.8
17.1
89.3
86.7
Operation not recommended
3.32
3.39
27.9
28.3
28.3
28.7
2.16
2.14
2.16
2.14
20.6
21.0
21.0
21.4
92.5
89.4
92.8
89.7
Operation not recommended
3.80
3.87
3.85
3.93
2.24
2.21
2.25
2.21
2.26
2.21
2.31
2.26
2.32
2.27
24.1
24.7
24.7
25.3
26.5
27.2
27.7
28.5
28.4
29.3
95.6
92.1
96.1
92.5
97.5
93.8
98.7
94.8
99.3
95.4
4.15
4.28
4.21
4.35
4.44
4.61
4.52
4.71
4.58
4.78
29.6
30.5
31.0
32.1
31.9
33.0
32.5
33.7
34.2
35.5
35.2
36.6
35.4
36.9
37.4
39.0
38.6
40.3
38.2
40.0
40.4
42.4
41.8
43.9
100.0
105.2
100.8
105.2
100.8
107.0
102.4
108.1
103.4
107.6
100.2
96.2
101.6
97.4
102.3
98.1
102.8
98.6
104.4
102.9
109.6
104.8
110.9
106.0
5.36
5.11
5.45
5.26
5.63
5.32
5.72
5.39
5.82
5.51
4.73
4.96
4.80
5.06
4.87
5.14
4.97
5.26
5.04
5.95
5.55
6.03
5.63
6.14
4.1
3.7
4.3
3.9
4.4
4.0
1150
1350
1150
1350
40.2
42.1
40.6
42.5
7.5
6.9
7.7
7.1
8.1
6.1
6.8
6.3
7.2
6.7
7.5
8.4
7.8
8.6
8.0
5.6
6.4
6.0
6.6
5.7
5.3
5.9
5.4
6.1
4.7
5.3
4.8
5.4
5.0
4.7
4.3
4.9
4.4
5.1
1350
1150
1350
1150
1350
1150
1350
1150
1350
1150
1350
1150
1350
1150
1350
1150
1350
1150
1350
1150
1350
1150
1350
1150
1150
1350
1150
1350
1150
1350
1150
1350
1150
1350
44.9
43.7
45.3
41.0
42.4
41.8
43.2
42.2
43.6
38.9
40.1
39.7
40.9
40.1
41.3
42.5
44.1
43.0
44.7
43.4
45.1
42.6
44.2
43.3
41.9
43.8
42.3
44.2
42.6
44.4
43.1
44.8
43.5
45.3
5.0
0.6
1.5
100
8.0
11.0
1.7
3.4
4.0
7.9
1150
1350
1150
1350
38.2
39.2
38.5
39.6
5.0
0.6
1.4
110
8.0
11.0
1.7
3.3
3.9
7.6
Operation not recommended
1150
1350
1150
1350
34.8
35.7
35.1
36.0
5.0
0.6
1.3
120
8.0
11.0
1.6
3.2
3.7
7.3
1150
1350
1150
1350
32.8
33.5
33.1
33.9
COOLING - EAT 80/67 °F
SC
Mbtu/h
S/T
Ratio
Power kW
HR
Mbtu/h
Operation not recommended
0.72
0.66
0.72
0.68
0.74
0.68
0.73
0.67
0.73
0.70
0.65
0.71
0.65
0.70
0.64
0.70
0.67
0.73
0.67
32.5
28.9
32.5
27.9
31.4
28.2
31.7
28.2
31.7
27.1
27.7
31.1
28.0
31.4
28.0
31.4
28.6
32.1
28.9
26.2
29.4
26.2
29.4
27.0
30.4
27.3
30.7
27.3
30.7
Operation not recommended
24.5
27.5
24.5
27.5
0.61
0.65
0.60
0.65
1.34
1.42
1.31
1.38
44.8
46.9
45.0
47.2
Operation not recommended
0.62
0.67
0.62
0.66
0.63
0.68
0.63
0.68
0.63
0.68
1.43
1.51
1.39
1.47
1.62
1.71
1.55
1.63
1.50
1.58
46.8
48.9
47.1
49.2
48.1
50.2
48.3
50.4
48.6
50.7
1.96
1.82
1.90
2.19
2.29
2.08
2.17
2.02
2.11
2.45
1.78
1.87
1.70
1.78
1.65
1.73
1.97
2.06
1.87
51.5
49.9
51.8
48.5
50.2
48.9
50.6
49.1
50.8
47.2
48.5
50.5
48.8
50.8
49.1
51.0
49.4
51.2
49.7
30.5
27.4
30.8
27.4
30.8
0.76
0.69
0.75
0.68
0.75
2.55
2.31
2.41
2.25
2.34
48.8
47.6
49.1
47.7
49.3
Operation not recommended
26.9
0.70
2.58
47.0
30.2
26.9
30.2
0.77
0.70
0.76
2.68
2.50
2.60
48.4
47.1
48.5
Operation not recommended
24.9
0.71
2.88
44.6
27.9
24.9
0.78
0.71
2.98
2.79
45.9
44.7
27.9
0.77
2.89
45.9
Operation not recommended
24.6
27.6
24.6
0.75
0.82
0.74
3.20
3.31
3.11
43.7
44.8
43.7
27.6
0.81
3.21
44.8
EER
HWC
Mbtu/h
29.9
29.6
31.1
30.8
22.9
24.1
23.8
18.7
18.5
20.1
19.9
20.9
20.7
15.9
15.7
17.1
17.0
17.8
17.6
23.8
23.6
25.4
25.1
26.4
26.1
21.6
21.4
23.1
29.3
29.0
30.5
30.1
26.3
26.0
27.9
27.6
29.0
28.7
14.8
14.6
15.4
15.2
12.1
12.0
12.6
12.5
10.2
10.1
10.7
10.6
8.5
9.2
7.9
8.8
6.9
7.5
6.4
7.2
---
---
---
---
10.3
11.1
9.5
10.6
2/10/12
4.5
4.8
4.1
4.6
6.0
3.8
3.3
3.6
4.8
5.1
6.4
5.6
6.1
5.2
5.8
2.9
3.8
4.0
3.5
3.0
3.2
2.8
3.0
2.6
2.6
2.3
2.5
2.1
2.4
---
---
---
---
2.5
50
T1GX, T2GX SERIES SPECIFICATION CATALOG
Performance Data cont.
Model 048 - Single Speed ECM or 5-Speed ECM (1500 cfm)
EWT
°F
Flow
Rate
GPM
6.0
WPD
PSI FT/HD
1.1
2.6
Airflow
CFM
HC
MBtu/h
HEATING - EAT 70°F
Power HE LAT kW MBtu/h °F
Operation not recommended
COP
HWC
Mbtu/h
9.0
2.3
5.4
Airflow
CFM
TC
Mbtu/h
20
12.0
6.0
4.0
1.1
9.2
2.5
1300
1500
31.6
32.0
2.84
2.82
21.9
22.4
92.5
89.7
Operation not recommended
3.26
3.33
5.3
4.8
30
9.0
12.0
2.3
3.9
5.3
9.0
1300
1500
1300
1500
5.6
5.2
5.8
5.3
1300
1500
1300
1500
48.2
50.5
48.7
51.0
40
50
60
70
80
90
6.0
9.0
12.0
6.0
9.0
12.0
6.0
9.0
12.0
6.0
9.0
12.0
6.0
9.0
12.0
6.0
9.0
12.0
1.1
2.2
3.8
1.0
2.1
3.7
1.0
2.1
3.5
1.0
2.0
3.4
0.9
1.9
3.3
0.9
1.9
3.2
2.5
5.1
8.7
2.4
4.9
8.4
2.3
4.8
8.2
2.2
4.6
7.9
2.1
4.5
7.6
2.1
4.3
7.4
1300
1500
1300
1500
1300
1500
1300
1500
1500
1300
1500
1300
1500
1300
1500
1300
1500
1300
1500
1300
1500
1300
1500
1300
1500
1300
1300
1500
1300
1500
1300
1500
1300
1500
3.37
3.23
3.50
3.35
3.55
3.39
3.45
3.29
3.18
3.31
3.20
3.29
3.17
3.40
3.27
3.44
3.31
3.61
3.43
3.67
3.48
57.1
58.6
60.1
61.7
61.8
63.5
60.7
62.4
52.3
52.5
53.6
53.6
54.7
56.1
57.4
57.6
59.0
64.1
66.0
66.1
68.1
44.7
45.4
46.5
47.3
47.4
48.2
49.1
50.0
51.3
36.3
36.7
36.8
37.2
2.92
2.90
2.93
2.90
26.3
26.8
26.8
27.3
95.8
92.6
96.2
93.0
3.64
3.71
3.68
3.76
41.7
Operation not recommended
3.05
31.3
99.7
4.00
42.2
42.4
43.0
3.00
3.06
3.01
32.0
31.9
32.7
96.1
100.2
96.5
4.13
4.06
4.19
3.09
3.02
3.16
3.08
3.18
3.10
3.18
3.10
3.28
34.1
35.1
35.7
36.7
36.6
37.7
38.2
39.5
40.1
101.8
98.0
103.1
99.2
103.8
99.8
105.0
100.9
106.5
4.24
4.40
4.32
4.49
4.37
4.56
4.52
4.74
4.59
41.5
41.2
42.7
42.4
43.9
44.5
46.3
45.8
47.7
45.6
47.5
48.1
50.3
49.7
51.9
48.9
51.2
51.7
54.3
53.5
56.2
110.7
106.2
112.8
108.1
114.0
109.2
113.2
108.5
102.3
107.4
103.1
108.2
103.8
110.0
105.5
111.0
106.4
115.6
110.7
117.0
112.0
4.97
5.32
5.03
5.40
5.10
5.49
5.16
5.56
4.83
4.65
4.91
4.78
5.05
4.84
5.14
4.91
5.22
5.20
5.64
5.27
5.74
10.1
9.4
10.7
9.9
11.1
10.2
11.4
10.6
9.6
8.8
9.8
9.1
7.9
8.8
8.1
9.0
8.3
7.2
8.0
7.4
8.5
7.2
6.5
7.6
7.0
7.8
6.7
6.2
6.9
6.4
6.2
5.7
6.4
5.8
1300
1500
1300
1500
1300
1500
1300
1500
1500
1300
1500
1300
1500
1300
1500
1300
1500
1300
1500
1300
1500
1300
1500
1300
1500
1300
1300
1500
1300
1500
1300
1500
1300
1500
49.0
50.7
44.5
45.9
45.4
46.8
45.9
47.3
51.5
50.5
52.3
51.0
52.9
47.7
49.3
48.5
50.2
52.2
54.4
50.0
51.9
50.6
52.6
51.1
53.1
49.7
50.1
52.3
50.6
52.9
51.2
53.3
51.7
53.9
6.0
0.9
2.0
100
9.0
12.0
1.8
3.1
4.2
7.1
1300
1500
1300
1500
43.9
45.1
44.3
45.6
6.0
0.8
1.9
110
9.0
12.0
1.7
3.0
4.0
6.8
Operation not recommended
1300
1500
1300
1500
39.7
40.7
40.1
41.1
6.0
0.8
1.8
120
9.0
12.0
1.7
2.8
3.8
6.6
1300
1500
1300
1500
37.6
38.4
37.9
38.8
COOLING - EAT 80/67 °F
SC S/T Power HR
Mbtu/h Ratio kW Mbtu/h
Operation not recommended
0.71
0.65
0.70
0.64
0.70
0.67
0.72
0.66
0.72
0.63
0.68
0.64
0.69
0.64
0.69
0.63
0.69
0.65
36.5
32.8
36.8
32.8
36.8
31.7
35.6
32.0
36.0
32.8
36.8
32.1
36.0
32.4
36.4
32.4
36.4
32.4
Operation not recommended
29.6
33.3
29.6
33.3
0.61
0.66
0.61
0.65
1.58
1.67
1.53
1.62
53.6
56.2
53.9
56.5
Operation not recommended
31.2
0.62
1.74
56.0
35.1
31.2
35.1
0.67
0.62
0.66
1.83
1.68
1.78
58.6
56.4
58.9
32.5
36.5
32.8
36.8
0.63
0.68
0.63
0.68
2.02
2.13
1.93
2.03
58.1
60.6
58.3
60.8
2.63
2.38
2.50
2.31
2.42
2.81
2.94
2.66
2.78
1.87
1.97
2.24
2.35
2.13
2.24
2.07
2.17
2.51
60.5
58.6
60.9
58.9
61.1
57.3
59.3
57.6
59.7
58.6
61.1
57.6
59.9
57.9
60.2
58.2
60.5
58.3
32.0
36.0
30.3
34.0
0.65
0.71
0.68
0.74
2.59
2.70
3.14
3.27
57.8
59.9
55.2
57.0
30.6
34.3
30.6
34.3
0.67
0.73
0.67
0.73
2.97
3.09
2.88
3.00
55.5
57.4
55.7
57.5
Operation not recommended
30.1
33.9
30.1
33.9
0.69
0.75
0.68
0.74
3.33
3.46
3.23
3.36
55.2
56.9
55.3
57.0
Operation not recommended
28.0
0.71
3.71
52.3
31.4
28.0
31.4
0.77
0.70
0.77
3.84
3.60
3.73
53.8
52.3
53.8
Operation not recommended
27.4
0.73
4.13
51.7
30.8
27.4
0.80
0.72
4.27
4.01
53.0
51.6
30.8
0.79
4.15
53.0
EER
HWC
Mbtu/h
30.5
30.2
31.8
31.4
19.0
18.8
14.2
14.0
15.3
15.1
15.9
15.7
19.6
21.2
21.0
22.0
21.8
17.0
16.8
18.2
18.0
27.9
27.6
22.3
22.1
23.7
23.5
24.7
24.4
19.8
28.9
28.6
30.0
29.7
25.3
25.1
26.8
26.6
13.2
13.0
13.7
13.6
10.7
10.6
11.1
11.0
9.1
9.0
9.5
9.4
8.1
8.8
7.5
8.4
9.9
10.8
9.2
10.2
---
---
---
---
12.0
13.0
11.1
12.4
2/10/12
6.5
7.1
6.1
6.7
4.8
5.4
7.0
7.4
5.6
5.9
5.2
5.6
4.7
4.1
4.5
3.8
4.2
3.6
3.0
3.4
4.4
2.5
2.8
3.5
3.7
3.3
2.9
3.1
2.7
2.9
---
---
---
---
51
T1GX, T2GX SERIES SPECIFICATION CATALOG
Performance Data cont.
Model 060 - Single Speed ECM or 5-Speed ECM (2000 cfm)
EWT
°F
Flow
Rate
GPM
9.0
WPD
PSI FT/HD
2.5
5.7
Airflow
CFM
HC
MBtu/h
HEATING - EAT 70°F
Power HE LAT kW MBtu/h °F
Operation not recommended
COP
HWC
Mbtu/h
12.0
4.0
9.2
Airflow
CFM
TC
Mbtu/h
20
15.0
9.0
5.9
2.4
13.5
5.5
1500
2000
38.6
39.4
3.70
3.77
26.0
26.5
93.8
88.2
Operation not recommended
3.06
3.06
6.5
5.8
30
12.0
15.0
3.9
5.7
8.9
13.1
1500
2000
1500
2000
6.8
6.2
7.0
6.4
1500
2000
1500
2000
73.6
71.2
74.3
72.4
40
50
60
70
80
90
9.0
12.0
15.0
9.0
12.0
15.0
9.0
12.0
15.0
9.0
12.0
15.0
9.0
12.0
15.0
9.0
12.0
15.0
2.3
3.7
5.5
2.2
3.6
5.3
2.2
3.5
5.2
2.1
3.4
5.0
2.0
3.3
4.8
2.0
3.2
4.7
5.3
8.7
12.7
5.2
8.4
12.3
5.0
8.1
11.9
4.9
7.9
11.6
4.7
7.6
11.2
4.5
7.3
10.8
1500
2000
1500
2000
1500
2000
1500
2000
2000
1500
2000
1500
2000
1500
2000
1500
2000
1500
2000
1500
2000
1500
2000
1500
2000
1500
1500
2000
1500
2000
1500
2000
1500
2000
4.41
4.41
4.48
4.44
4.54
4.57
4.54
4.53
4.21
4.23
4.28
4.29
4.31
4.33
4.35
4.40
4.44
4.65
4.53
4.69
4.72
74.3
75.7
77.7
78.3
78.9
80.5
79.3
80.6
65.8
66.3
67.7
69.5
71.0
72.0
72.4
73.4
75.1
83.5
84.5
84.7
86.2
57.3
57.9
57.9
59.4
59.4
60.5
63.3
64.4
64.9
43.5
44.4
44.9
45.8
3.70
3.77
3.80
3.86
30.9
31.5
31.9
32.6
96.9
90.5
97.7
91.2
3.45
3.45
3.46
3.47
51.3
Operation not recommended
3.86
38.2
101.7
3.90
52.5
52.8
53.8
3.94
3.94
4.01
39.1
39.3
40.1
94.3
102.6
94.9
3.91
3.92
3.93
4.00
4.05
3.99
4.09
4.08
4.13
4.14
4.17
4.16
43.6
44.1
44.3
45.5
45.5
46.4
49.2
50.1
50.7
105.4
96.8
105.7
97.5
106.6
98.0
109.1
99.8
110.0
4.19
4.19
4.25
4.26
4.27
4.29
4.48
4.52
4.57
51.4
51.9
53.1
54.9
56.3
57.2
57.5
58.4
59.9
59.3
60.6
62.4
63.2
63.4
64.9
63.8
65.1
67.7
69.1
68.6
70.0
115.9
105.0
117.9
106.3
118.7
107.3
119.0
107.3
100.5
110.9
101.3
112.9
102.9
114.5
103.5
115.3
104.7
121.6
109.1
122.3
109.9
4.94
5.03
5.08
5.18
5.10
5.16
5.12
5.21
4.57
4.59
4.63
4.75
4.83
4.87
4.87
4.89
4.95
5.27
5.47
5.29
5.35
12.2
11.3
13.0
12.0
13.4
12.4
13.8
12.8
9.5
10.6
9.8
10.9
10.0
11.5
10.7
11.9
11.0
8.6
7.9
9.1
8.4
9.4
8.7
9.7
8.9
10.3
8.1
7.5
8.4
7.7
7.5
6.9
7.8
7.1
1500
2000
1500
2000
1500
2000
1500
2000
2000
1500
2000
1500
2000
1500
2000
1500
2000
1500
2000
1500
2000
1500
2000
1500
2000
1500
1500
2000
1500
2000
1500
2000
1500
2000
65.1
66.7
60.9
61.3
61.3
61.9
61.9
62.6
68.8
66.2
69.5
66.8
69.5
64.1
65.7
64.4
66.4
73.0
73.1
68.5
70.0
68.7
70.4
69.4
70.8
65.9
71.9
71.3
72.6
72.1
72.2
72.4
72.3
72.4
9.0
1.9
4.4
100
12.0
15.0
3.1
4.5
7.1
10.4
1500
2000
1500
2000
58.8
59.4
59.4
60.0
9.0
1.8
4.2
110
12.0
15.0
2.9
4.3
6.8
10.0
Operation not recommended
1500
2000
1500
2000
53.8
54.4
54.4
54.9
9.0
1.7
4.0
120
12.0
15.0
2.8
4.2
6.5
9.6
1500
2000
1500
2000
51.8
50.8
52.3
51.7
COOLING - EAT 80/67 °F
SC S/T Power HR
Mbtu/h Ratio kW Mbtu/h
Operation not recommended
0.71
0.69
0.71
0.69
0.71
0.70
0.73
0.70
0.72
0.67
0.69
0.68
0.70
0.68
0.70
0.67
0.70
0.69
49.1
45.5
49.1
45.8
49.6
44.6
47.7
45.0
47.7
48.7
50.7
46.2
49.1
46.4
49.3
46.7
49.6
45.2
Operation not recommended
46.9
48.3
47.0
47.8
0.64
0.68
0.63
0.66
2.16
2.61
2.16
2.44
81.0
80.2
81.7
80.8
Operation not recommended
47.4
0.66
2.40
80.1
49.5
47.6
49.3
0.69
0.66
0.68
2.81
2.39
2.65
80.9
80.8
81.2
48.4
50.2
48.5
50.7
0.67
0.69
0.67
0.70
2.81
3.15
2.71
3.09
81.8
83.1
81.6
82.9
3.68
3.29
3.54
3.25
3.44
3.81
4.06
3.66
3.87
2.70
2.94
3.04
3.33
2.93
3.24
2.91
3.12
3.42
81.3
77.4
81.6
77.9
81.2
77.0
79.6
76.9
79.6
82.2
83.2
78.9
81.4
78.7
81.4
79.3
81.4
77.5
45.4
48.2
43.2
45.5
0.70
0.72
0.71
0.74
3.60
3.76
4.20
4.45
77.4
79.6
75.2
76.5
43.7
45.5
44.1
46.0
0.71
0.73
0.71
0.73
4.03
4.20
3.96
4.08
75.1
76.3
75.4
76.5
Operation not recommended
42.9
44.7
43.4
45.2
0.73
0.75
0.73
0.75
4.59
4.70
4.49
4.58
74.5
75.5
74.8
75.7
Operation not recommended
39.9
0.74
5.08
71.2
41.5
40.4
42.1
0.76
0.74
0.77
5.14
4.96
5.01
71.9
71.3
72.0
Operation not recommended
40.5
0.78
5.78
71.5
41.2
41.1
0.81
0.78
5.80
5.62
70.6
71.5
41.7
0.81
5.63
70.9
EER
HWC
Mbtu/h
34.1
27.3
34.4
29.6
18.1
17.8
14.5
13.8
15.2
14.7
15.7
15.3
18.7
20.1
19.6
20.6
20.2
16.8
16.2
17.6
17.2
27.1
24.9
22.5
21.0
23.4
21.7
23.9
22.7
19.3
30.0
25.4
30.4
27.2
25.7
23.0
26.7
23.5
12.8
12.6
13.2
13.1
10.6
10.6
11.0
11.0
9.0
8.8
9.3
9.2
10.9
11.8
10.1
11.2
13.4
14.5
12.4
13.8
---
---
---
---
16.1
17.5
15.0
16.7
2/10/12
6.5
7.2
9.4
10.0
8.8
9.5
8.2
9.1
7.5
8.0
7.0
7.6
6.3
5.5
6.0
5.1
5.7
4.8
4.1
4.6
5.9
3.4
3.7
4.7
5.0
4.4
3.9
4.1
3.6
3.9
---
---
---
---
52
T1GX, T2GX SERIES SPECIFICATION CATALOG
Performance Data cont.
Model 070 - Single Speed ECM or 5-Speed ECM (2200 cfm)
EWT
°F
Flow
Rate
GPM
12.0
WPD
PSI FT/HD
3.0
7.0
Airflow
CFM
HC
MBtu/h
HEATING - EAT 70°F
Power HE LAT kW MBtu/h °F
Operation not recommended
COP
HWC
Mbtu/h
15.0
4.4
10.2
Airflow
CFM
TC
Mbtu/h
20
18.0
12.0
6.0
3.0
13.9
6.8
1700
2200
45.6
46.6
4.45
4.54
30.4
31.2
94.8
89.6
Operation not recommended
3.00
3.01
7.7
6.9
30
15.0
18.0
4.3
5.8
9.9
13.5
8.1
7.4
8.4
7.6
1700
2200
1700
2200
69.3
73.9
69.7
74.3
40
50
60
70
80
90
12.0
15.0
18.0
12.0
15.0
18.0
12.0
15.0
18.0
12.0
15.0
18.0
12.0
15.0
18.0
12.0
15.0
18.0
2.9
4.1
5.7
2.8
4.0
5.5
2.7
3.9
5.3
2.6
3.8
5.1
2.5
3.6
5.0
2.4
3.5
4.8
6.6
9.6
13.1
6.4
9.3
12.7
6.2
9.0
12.3
6.0
8.7
11.9
5.8
8.4
11.5
5.6
8.1
11.1
1700
2200
1700
2200
1700
2200
1700
2200
1700
2200
1700
2200
1700
2200
1700
2200
1700
2200
1700
2200
1700
2200
1700
2200
1700
2200
1700
2200
1700
2200
1700
2200
1700
2200
1700 99.2
2200 102.2
1700 100.9
2200 104.2
88.2
90.7
92.2
94.8
93.6
96.5
94.2
97.0
79.1
78.0
80.0
82.6
84.8
85.6
87.9
86.8
89.1
67.6
69.2
68.9
70.6
69.5
71.3
74.9
76.8
77.1
52.5
53.8
52.7
54.0
4.55
4.65
4.57
4.66
37.0
37.9
37.1
38.1
98.6
92.6
98.7
92.7
3.38
3.39
3.38
3.39
61.3
Operation not recommended
4.75
45.1
103.4
3.78
62.8
61.7
63.2
4.80
4.77
4.82
46.4
45.4
46.7
96.4
103.6
96.6
3.83
3.79
3.84
4.89
4.91
4.94
4.95
4.97
4.98
5.09
5.06
5.16
5.12
5.20
5.15
5.30
5.22
5.40
5.30
5.44
5.34
5.50
5.37
5.62
5.47
5.68
5.52
5.72
5.53
5.87
5.66
5.93
5.71
50.9
52.4
52.1
53.7
52.6
54.3
57.5
59.5
59.5
61.6
60.2
62.4
64.5
66.9
67.2
69.8
68.2
70.9
69.4
72.3
73.0
76.2
74.3
77.6
74.7
78.1
79.2
82.9
80.7
84.8
106.8
99.1
107.5
99.7
107.9
100.0
110.8
102.3
112.0
103.3
112.5
103.7
115.0
105.7
116.6
107.0
117.3
107.5
118.0
108.2
120.2
109.9
121.0
110.6
121.3
110.8
124.1
113.0
125.0
113.9
4.53
4.39
4.55
4.57
4.76
4.65
4.86
4.67
4.89
4.05
4.13
4.09
4.18
4.10
4.20
4.31
4.45
4.38
4.96
5.29
4.99
5.35
4.70
4.95
4.81
5.08
4.83
5.12
4.83
5.14
14.6
13.5
15.4
14.3
15.9
14.7
16.4
15.2
11.3
12.6
11.6
13.0
11.9
13.7
12.7
14.1
13.1
10.3
9.4
10.8
10.0
11.2
10.3
11.5
10.6
12.2
8.9
8.2
9.2
8.4
9.7
8.9
10.0
9.2
1700
2200
1700
2200
1700
2200
1700
2200
2200
1700
2200
1700
2200
1700
2200
1700
2200
1700
2200
1700
2200
1700
2200
1700
2200
1700
1700
2200
1700
2200
1700
2200
1700
2200
70.5
73.6
63.4
66.0
63.6
66.2
64.9
67.5
75.5
72.3
75.8
73.4
76.9
69.1
72.1
69.3
72.4
76.3
80.6
72.3
76.1
72.6
76.4
73.5
77.4
72.0
71.7
76.1
72.2
76.6
75.1
79.4
75.5
79.8
12.0
2.3
5.4
100
15.0
18.0
3.4
4.6
7.8
10.7
1700
2200
1700
2200
61.7
64.0
63.1
65.4
12.0
2.2
5.2
110
15.0
18.0
3.3
4.4
7.5
10.2
Operation not recommended
1700
2200
1700
2200
54.8
56.5
56.1
57.9
12.0
2.2
5.0
120
15.0
18.0
3.1
4.3
7.2
9.8
1700
2200
1700
2200
52.0
53.4
53.4
54.9
COOLING - EAT 80/67 °F
SC S/T Power HR
Mbtu/h Ratio kW Mbtu/h
Operation not recommended
0.72
0.66
0.72
0.66
0.72
0.66
0.72
0.66
0.72
0.64
0.69
0.65
0.70
0.65
0.70
0.65
0.70
0.66
54.4
47.6
54.5
48.7
55.7
45.5
52.1
45.5
52.1
48.9
55.9
46.9
53.6
47.0
53.8
47.6
54.5
47.5
Operation not recommended
43.4
49.6
42.9
49.0
0.63
0.67
0.62
0.66
2.39
2.79
2.38
2.78
77.5
83.4
77.8
83.8
Operation not recommended
46.1
0.64
2.63
80.6
52.7
45.9
52.5
0.69
0.64
0.68
3.03
2.61
3.01
86.4
81.1
86.9
48.4
55.4
48.7
55.7
0.64
0.70
0.64
0.70
3.01
3.43
2.92
3.33
85.4
91.1
85.5
91.2
4.11
3.59
3.99
3.53
3.93
4.12
4.53
4.00
4.40
2.89
3.29
3.31
3.72
3.22
3.62
3.17
3.57
3.69
89.5
84.5
89.4
85.4
90.3
83.1
87.6
82.9
87.4
86.1
91.9
83.5
88.8
83.5
88.8
84.3
89.5
84.6
46.9
53.7
42.2
48.4
0.67
0.73
0.67
0.73
3.92
4.31
4.57
4.98
83.9
88.3
79.0
83.0
42.1
48.3
43.8
50.3
0.66
0.73
0.68
0.74
4.45
4.84
4.35
4.73
78.8
82.7
79.7
83.6
Operation not recommended
41.6
47.7
43.7
50.1
0.67
0.75
0.69
0.77
5.01
5.39
4.88
5.24
78.9
82.4
79.8
83.3
Operation not recommended
37.0
0.67
5.58
73.8
42.4
39.1
44.9
0.75
0.70
0.78
5.94
5.41
5.76
76.8
74.6
77.6
Operation not recommended
37.4
0.72
6.27
73.4
43.0
40.0
0.80
0.75
6.60
6.06
76.0
74.1
45.9
0.84
6.38
76.7
EER
HWC
Mbtu/h
29.0
26.5
29.3
26.7
18.0
17.1
13.9
13.3
14.3
13.7
14.9
14.3
18.4
20.2
19.0
20.8
19.6
16.8
15.9
17.3
16.4
26.4
24.5
21.8
20.4
22.6
21.1
23.2
21.7
19.5
27.3
25.1
27.7
25.5
24.9
23.2
25.8
24.0
12.3
11.9
12.9
12.5
9.8
9.5
10.4
10.0
8.3
8.1
8.8
8.6
12.0
13.0
11.1
12.3
14.6
15.9
13.6
15.1
---
---
---
---
17.7
19.2
16.4
18.2
2/10/12
7.1
7.9
10.3
10.9
9.6
10.4
8.9
9.9
8.2
8.7
7.7
8.3
6.9
6.1
6.6
5.6
6.3
5.2
4.5
5.0
6.5
3.7
4.1
5.2
5.5
4.8
4.3
4.5
4.0
4.3
---
---
---
---
53
T1GX, T2GX SERIES SPECIFICATION CATALOG
Performance Data cont.
Model 026 - Part Load Dual Capacity with Variable Speed ECM or 5-Speed ECM (700 cfm)
EWT °F
Flow
Rate
GPM
WPD
Airflow
CFM
HC
MBtu/h
HEATING - EAT 70°F
Power kW
HE
MBtu/h
LAT
°F
COP
Operation not recommended
HWC
Mbtu/h
Airflow
CFM
TC
Mbtu/h
COOLING - EAT 80/67 °F
SC
Mbtu/h
S/T
Ratio
Power kW
HR
Mbtu/h
EER
HWC
Mbtu/h
3.0
5.0
PSI FT/HD
0.8
2.0
1.9
4.7
20
7.0
3.7
8.7
500
700
1.8
1.6
Operation not recommended
30
40
50
60
70
80
90
100
110
120
3.0
5.0
7.0
3.0
5.0
7.0
3.0
5.0
7.0
3.0
5.0
7.0
3.0
5.0
7.0
3.0
5.0
7.0
3.0
5.0
7.0
3.0
5.0
7.0
3.0
5.0
7.0
3.0
5.0
7.0
0.8
2.0
3.6
0.8
1.9
3.5
0.7
1.8
3.4
0.7
1.8
3.3
0.7
1.7
3.2
0.7
1.7
3.1
0.7
1.6
3.0
0.6
1.6
2.9
0.6
1.5
2.8
0.6
1.4
2.7
1.8
4.5
8.4
1.8
4.4
8.2
1.7
4.3
7.9
1.7
4.1
7.6
1.6
4.0
7.4
1.6
3.9
7.1
1.5
3.7
6.9
1.5
3.6
6.6
1.4
3.4
6.4
1.3
3.3
6.1
500
700
500
700
500
700
500
700
500
700
500
700
500
700
500
700
500
700
500
700
500
700
500
700
500
700
500
700
500
700
500
700
500
700
500
700
500
700
11.9
1.06
8.3
92.0
3.28
12.4
1.09
8.7
86.4
3.33
Operation not recommended
13.1
1.06
9.5
94.3
3.61
19.9
20.2
20.7
20.9
21.4
21.9
22.4
22.9
16.8
17.4
17.4
18.0
18.3
18.8
19.4
13.7
13.9
14.5
1.09
1.09
1.12
9.9
10.2
10.7
88.1
3.66
95.8
3.75
89.2
3.80
15.3
Operation not recommended
1.06
11.7
98.3
4.21
15.8
16.1
16.7
1.08
1.09
1.11
12.1
12.4
12.9
90.9
99.8
92.0
4.28
4.33
4.40
23.3
23.5
23.9
24.4
24.7
25.5
25.8
25.9
26.2
26.8
27.0
28.1
28.3
28.3
28.4
1.06
1.08
1.06
1.08
1.09
1.10
1.08
1.09
1.08
1.08
1.10
1.11
1.09
1.09
1.09
1.09
1.11
1.11
1.12
1.12
1.12
1.11
1.14
1.13
1.16
1.14
1.15
1.13
1.17
1.15
13.2
13.7
13.8
14.3
14.6
103.8
4.92
15.0
15.7
105.9
5.28
16.2
16.5
107.4
5.50
17.0
17.1
108.7
5.56
17.6
18.2
110.6
5.88
18.6
19.2
101.2
93.0
102.3
93.8
4.90
94.9
5.01
96.3
5.37
97.3
5.60
98.2
99.6
112.4
Operation not recommended
4.65
4.73
4.81
5.66
5.99
6.16
19.6
100.8
6.28
19.7
113.5
6.19
20.1
101.6
6.31
20.5
115.1
6.35
20.9
102.7
6.47
21.7
117.3
6.70
22.0
104.2
6.83
22.0
117.9
6.65
22.3
104.6
6.78
22.8
119.6
6.79
23.1
105.7
6.93
24.2
122.1
7.20
24.5
107.5
7.35
24.3
122.4
7.09
24.5
107.6
7.24
1.8
1.6
1.8
1.6
1.8
1.7
1.9
1.7
1.9
1.7
1.9
1.8
2.0
1.8
2.1
1.9
2.1
2.0
2.2
2.0
2.3
2.1
2.4
2.2
2.4
2.2
2.6
2.4
2.6
2.4
2.7
2.5
2.9
2.7
3.0
2.8
3.1
2.8
500
700
500
700
500
700
500
700
500
700
500
700
500
700
500
700
500
700
500
700
500
700
500
700
500
700
500
700
500
700
500
700
500
700
500
700
500
700
500
700
500
700
500
700
500
700
500
700
500
700
22.5
22.9
22.6
23.2
23.3
23.7
23.5
24.0
23.5
24.2
23.7
24.4
24.1
24.8
23.1
23.7
23.3
24.0
23.7
24.4
22.7
23.3
22.9
23.5
23.3
23.9
21.1
21.7
21.3
21.9
21.6
22.3
19.5
20.1
19.7
20.3
20.0
20.6
18.2
18.7
18.5
19.1
16.8
17.2
17.0
17.5
16.2
16.5
16.4
16.7
0.64
0.69
0.64
0.68
0.64
0.69
0.65
0.70
0.65
0.70
0.66
0.71
0.66
0.62
0.67
0.63
0.68
0.63
0.67
0.63
0.68
14.5
16.0
14.5
16.1
14.9
16.5
13.8
15.3
13.9
15.4
14.2
15.8
16.2
15.0
16.6
14.5
16.0
14.6
16.1
15.0
16.6
Operation not recommended
14.1
0.63
0.52
24.3
15.4
14.1
15.4
0.67
0.62
0.66
0.55
0.50
0.53
24.8
24.4
25.0
Operation not recommended
14.7
0.63
0.58
25.3
16.0
14.7
16.0
0.67
0.62
0.67
0.61
0.56
0.59
25.8
25.4
26.0
14.5
16.1
14.6
0.62
0.67
0.62
0.66
0.67
0.64
25.8
26.5
25.9
0.84
0.86
0.82
0.84
0.81
0.83
0.97
0.99
0.95
0.96
0.94
0.96
0.66
0.64
0.65
0.75
0.77
0.73
0.75
0.73
0.74
25.6
26.2
25.7
26.4
26.0
26.7
24.4
25.1
24.5
25.2
24.8
25.5
26.6
26.3
27.0
25.7
26.4
25.8
26.5
26.2
26.9
13.1
14.5
13.2
14.6
13.6
15.0
0.67
0.72
0.67
0.72
0.68
0.73
1.10
1.12
1.07
1.09
1.06
1.08
Operation not recommended
12.6
0.69
1.23
22.4
14.0
13.0
14.4
0.75
0.70
0.75
1.25
1.22
1.24
23.0
22.7
23.3
Operation not recommended
12.1
0.72
1.39
21.5
13.4
12.4
0.78
0.73
1.41
1.37
22.0
21.7
23.3
23.9
23.4
24.0
23.7
24.3
13.7
0.78
1.40
22.3
Operation not recommended
12.4
13.5
12.4
13.5
0.77
0.82
0.76
0.81
1.59
1.63
1.54
1.59
21.6
22.1
21.6
22.1
43.3
41.8
44.9
43.8
26.9
27.1
27.8
28.1
28.6
28.8
21.8
21.9
22.5
22.7
23.1
23.3
17.8
18.0
18.4
18.6
18.9
19.1
37.2
37.8
38.2
30.7
31.0
31.8
32.1
32.6
32.9
40.1
38.9
41.6
40.7
35.6
35.9
36.9
14.9
15.0
15.2
15.4
12.1
12.2
12.4
12.5
10.2
10.1
10.6
10.5
-
-
-
-
1.3
1.4
1.3
1.4
1.2
1.3
1.8
1.9
1.7
1.9
1.6
1.8
2.4
2.6
2.3
2.5
2.1
2.4
1.0
0.9
1.0
0.8
0.9
0.7
0.6
0.7
1.0
0.7
0.8
0.7
-
-
-
-
3.0
3.2
2.8
3.1
3.8
4.1
3.5
3.9
4.7
5.1
4.3
4.8
Performance capacities shown in thousands of Btuh 9/16/14
54
T1GX, T2GX SERIES SPECIFICATION CATALOG
Performance Data cont.
Model 026 - Full Load Dual Capacity with Variable Speed ECM or 5-Speed ECM (900 cfm)
COOLING - EAT 80/67 °F
EWT
°F
Flow
Rate
GPM
WPD
PSI FT/HD
20
4.0
6.0
1.4
2.9
3.2
6.6
HEATING - EAT 70°F
Airflow
CFM
HC
MBtu/h
Power kW
HE
MBtu/h
LAT
°F
Operation not recommended
COP
HWC
Mbtu/h
Airflow
CFM
TC
Mbtu/h
30
40
50
60
70
80
90
100
110
120
8.0
4.0
6.0
8.0
4.0
6.0
8.0
4.0
6.0
8.0
4.0
6.0
8.0
4.0
6.0
8.0
4.0
6.0
8.0
4.0
6.0
8.0
4.0
6.0
8.0
4.0
6.0
8.0
4.0
6.0
8.0
4.8
1.4
2.8
4.7
1.3
2.7
4.5
1.3
2.6
4.4
1.2
2.5
4.2
1.2
2.4
4.1
1.2
2.4
4.0
1.1
2.3
3.8
1.1
2.2
3.7
1.0
2.1
3.5
1.0
2.0
3.4
11.1
3.2
6.4
10.8
3.1
6.2
10.4
3.0
6.0
10.1
2.9
5.8
9.8
2.8
5.6
9.5
2.7
5.4
9.2
2.6
5.2
8.8
2.5
5.1
8.5
2.4
4.9
8.2
2.3
4.7
7.9
700
900
700
900
700
900
700
900
700
900
700
900
700
900
700
900
700
900
700
900
700
900
700
900
700
900
700
900
700
900
700
900
700
900
700
900
700
900
700
900
33.8
35.0
35.9
37.2
37.0
38.3
16.5
17.0
1.42
1.46
11.6
12.0
91.8
3.40
87.5
3.41
18.9
Operation not recommended
1.45
13.9
95.0
3.82
19.4
19.2
19.8
1.50
1.47
1.51
14.3
14.2
14.7
90.0
3.81
95.4
3.84
90.4
3.85
29.7
30.2
31.2
30.9
32.0
31.2
32.3
33.0
34.2
34.0
35.2
25.0
24.7
25.5
26.0
26.8
27.2
28.1
27.8
28.8
28.7
21.5
Operation not recommended
1.50
16.4
98.5
4.21
22.2
22.0
1.53
1.51
17.0
16.8
92.8
99.1
4.25
4.25
22.7
23.3
24.0
24.2
1.55
1.51
1.53
1.55
17.4
18.2
18.8
18.9
93.3
100.9
94.7
102.0
4.30
4.53
4.60
4.59
1.57
1.56
1.58
1.58
1.59
1.63
1.64
1.64
1.65
1.65
19.6
19.4
20.1
20.6
21.4
21.6
22.5
22.2
23.1
23.1
95.7
102.7
96.2
104.4
97.6
105.9
98.9
106.8
99.6
108.0
4.67
4.65
4.73
4.82
4.94
4.90
5.02
4.96
5.11
5.09
1.65
1.71
1.71
1.73
1.72
1.75
1.74
1.82
1.80
1.84
1.82
24.0
24.3
25.3
25.1
26.1
25.3
26.4
26.8
28.0
27.7
29.0
100.5
5.27
109.9
5.18
102.1
5.35
110.9
5.25
102.9
5.45
111.3
5.23
103.3
5.46
113.7
5.32
105.1
5.56
115.0
5.41
106.2
5.68
1.85
1.82
1.93
1.90
1.96
1.91
27.5
28.8
29.3
30.7
30.3
31.8
114.7
5.36
106.0
5.63
117.5
5.45
108.2
5.74
119.0
5.54
109.4
5.88
Operation not recommended
2.1
2.0
2.3
2.1
2.3
2.2
3.4
3.9
3.6
4.0
3.7
4.1
3.8
3.2
3.6
3.3
3.7
2.9
3.3
3.0
3.5
2.7
2.5
2.8
2.6
2.5
2.3
2.6
2.4
2.9
2.7
3.1
2.9
3.2
4.3
4.0
4.5
4.1
4.6
4.3
700
900
700
900
900
700
900
700
900
700
900
900
700
900
700
900
700
900
700
700
900
700
900
700
900
700
900
700
900
700
900
700
700
900
700
900
700
900
700
900
700
900
700
900
700
900
700
900
700
900
29.8
30.3
30.0
30.7
30.5
27.0
28.0
27.7
28.8
28.0
29.2
30.5
29.4
30.9
28.2
29.4
28.9
30.1
29.2
30.1
30.7
30.3
31.0
28.8
30.3
29.4
31.0
29.7
31.3
28.5
29.9
29.2
25.7
26.7
26.5
27.5
26.8
27.8
24.9
25.7
25.2
26.0
23.3
24.0
23.6
24.2
21.6
22.0
21.8
22.3
SC
Mbtu/h
S/T
Ratio
Power kW
HR
Mbtu/h
EER
HWC
Mbtu/h
Operation not recommended
Operation not recommended
18.6
0.62
0.93
33.0
20.3
18.6
20.3
0.67
0.62
0.66
0.98
0.90
0.95
33.6
33.1
33.9
20.1
18.2
20.2
19.0
21.0
17.8
19.8
18.0
20.0
18.5
20.5
20.0
19.2
21.3
17.9
19.9
18.1
20.1
19.1
21.2
18.0
Operation not recommended
19.1
0.63
1.02
33.6
20.8
19.1
0.68
0.63
1.07
0.99
34.3
33.7
20.8
17.8
19.7
18.0
0.67
0.62
0.65
0.61
1.04
1.17
1.23
1.10
34.5
32.8
34.5
33.2
0.64
0.65
0.68
0.63
0.67
0.62
0.66
0.65
0.68
0.64
1.16
1.08
1.13
1.28
1.34
1.22
1.27
1.19
1.24
1.39
34.9
33.4
35.2
32.9
34.4
33.3
34.9
33.5
35.1
32.9
0.68
0.63
0.67
0.65
0.69
0.66
0.71
0.65
0.69
0.66
0.70
1.44
1.33
1.38
1.30
1.35
1.54
1.59
1.49
1.53
1.46
1.50
34.3
33.4
34.8
33.6
35.1
32.2
33.5
32.8
34.0
33.0
34.3
17.6
19.5
17.8
19.8
0.68
0.73
0.67
0.72
1.69
1.73
1.64
1.68
31.5
32.6
32.1
33.2
18.0
19.9
0.67
0.72
1.62
1.65
32.3
33.4
Operation not recommended
17.3
0.69
1.85
31.2
19.2
17.2
0.74
0.68
1.88
1.82
32.1
31.4
19.1
0.73
1.85
32.3
Operation not recommended
16.7
18.6
16.5
18.2
0.72
0.78
0.70
0.75
2.05
2.07
2.02
2.04
30.3
31.0
30.4
31.2
Operation not recommended
16.1
0.74
2.28
29.4
17.5
16.1
17.5
0.79
0.74
0.78
2.34
2.21
2.28
30.0
29.4
30.1
32.0
30.8
33.1
32.3
22.6
17.5
17.7
18.6
18.8
19.2
19.4
24.1
24.8
24.9
20.3
20.4
21.7
21.9
22.5
29.4
28.5
30.5
29.8
24.6
24.6
26.7
26.8
27.6
27.7
22.3
22.3
24.0
15.2
15.4
16.1
16.3
16.6
16.8
13.5
13.7
13.9
14.1
11.4
11.6
11.7
11.9
9.5
9.4
9.9
9.8
1.9
2.5
2.7
2.3
2.5
2.2
2.4
2.1
1.9
2.0
1.7
1.6
1.4
1.6
2.0
1.3
1.4
1.3
1.4
-
-
-
-
1.2
1.3
1.6
1.7
1.5
3.1
3.3
2.9
3.2
2.7
3.0
3.6
3.9
3.3
3.7
---
---
---
---
4.4
4.7
4.1
4.5
5.3
5.7
4.9
5.4
9/16/14
55
T1GX, T2GX SERIES SPECIFICATION CATALOG
EWT
°F
Flow
Rate
GPM
20
4.0
6.0
8.0
4.0
6.0
30
8.0
4.0
6.0
40
8.0
Performance Data cont.
Model 038 - Part Load Dual Capacity with Variable Speed ECM or 5-Speed ECM (1050 cfm)
50
60
70
80
90
100
110
120
4.0
6.0
8.0
4.0
6.0
8.0
4.0
6.0
8.0
4.0
6.0
8.0
4.0
6.0
8.0
4.0
6.0
8.0
4.0
6.0
8.0
4.0
6.0
8.0
900
1050
900
1050
900
1050
900
1050
900
1050
900
1050
900
1050
900
1050
1050
900
1050
900
1050
900
1050
900
1050
900
1050
900
1050
900
1050
900
1050
900
HEATING - EAT 70°F
WPD
PSI FT/HD
0.9
1.7
2.1
4.0
Airflow
CFM
HC
MBtu/h
Power kW
HE
MBtu/h
LAT
°F
Operation not recommended
COP
2.9
0.9
1.7
2.8
0.8
1.6
2.7
0.8
1.6
2.6
0.8
1.5
2.5
0.8
1.5
2.5
0.7
1.4
2.4
0.7
1.4
2.3
6.7
2.0
3.9
6.5
1.9
3.8
6.3
1.9
3.7
6.1
1.8
3.6
5.9
1.8
3.5
5.7
1.7
3.3
5.5
1.6
3.2
5.3
900
1050
900
1050
900
1050
35.5
36.7
37.1
37.2
37.6
38.6
38.9
40.5
40.8
40.7
40.9
31.4
32.0
32.8
33.4
33.6
34.2
35.0
1.76
1.76
1.74
1.79
1.78
1.83
1.81
1.81
1.79
1.85
1.82
1.71
1.71
1.70
1.70
1.74
1.74
1.77
24.8
25.6
25.7
26.5
26.9
27.7
28.1
28.8
29.3
29.9
30.3
31.0
17.6
18.4
19.2
20.0
20.5
21.3
22.5
23.3
23.7
24.5
1.63
1.67
12.1
12.7
88.1
86.2
Operation not recommended
1.58
13.8
89.8
1.62
1.62
14.5
14.9
87.7
91.0
1.66
15.6
88.8
Operation not recommended
1.60
1.63
1.64
1.67
17.0
17.7
18.1
18.8
93.1
90.5
94.4
91.6
1.63
1.65
1.63
1.65
1.67
1.69
1.67
1.68
1.67
1.68
1.70
1.71
19.3
20.0
20.1
20.8
21.2
21.9
22.4
23.1
23.6
24.2
24.5
25.1
3.17
3.22
3.57
3.62
3.71
3.76
4.11
4.17
4.23
4.29
95.5
92.6
96.4
93.3
97.7
94.4
98.9
95.4
100.1
5.15
96.4
5.24
101.2
5.21
97.3
5.30
4.47
4.55
4.62
4.70
4.73
4.81
4.94
5.03
29.5
30.7
31.1
31.1
31.5
32.3
32.7
34.4
34.7
34.4
34.7
25.6
26.2
27.0
27.6
27.7
28.3
29.0
102.3
5.39
98.3
5.49
103.7
5.64
99.4
5.75
104.6
5.67
100.2
5.78
106.0
5.80
101.3
5.91
107.7
6.12
102.7
6.24
108.3
6.08
103.1
6.20
109.7
6.19
104.3
6.31
111.7
6.56
106.0
6.70
111.9
6.46
106.1
6.59
0.7
1.6
1.3
2.2
0.7
1.3
2.1
0.6
1.2
2.0
3.1
5.1
1.5
3.0
4.9
1.5
2.9
4.7
Operation not recommended
900
1050
900
1050
900
1050
900
1050
23.1
23.7
23.4
24.1
22.2
22.6
22.4
22.9
COOLING - EAT 80/67 °F
HWC
Mbtu/h
Airflow
CFM
TC
Mbtu/h
SC
Mbtu/h
2.5
2.3
2.4
2.2
2.5
2.3
2.5
2.3
2.6
2.4
2.6
2.4
2.7
2.5
2.8
2.5
2.9
2.6
3.0
2.7
3.0
2.8
3.2
2.9
3.3
3.0
3.4
3.1
3.6
3.3
3.7
3.4
3.8
3.5
4.0
3.7
4.2
3.8
4.3
4.0
900
1050
900
1050
900
1050
900
1050
900
1050
900
1050
900
1050
900
1050
900
1050
900
1050
900
1050
900
1050
900
1050
900
1050
900
1050
900
1050
900
1050
900
1050
900
1050
900
1050
900
1050
29.5
30.0
29.7
30.4
30.8
31.3
31.0
31.7
31.3
32.2
31.6
32.5
32.1
33.0
30.5
31.3
30.8
31.6
31.3
32.2
29.7
30.5
30.0
30.8
30.5
31.3
28.1
28.9
28.3
29.1
28.8
29.6
26.5
27.2
26.7
27.4
27.1
27.9
24.9
25.6
25.3
26.0
S/T
Ratio
Power kW
HR
Mbtu/h
Operation not recommended
21.1
23.4
21.2
23.5
21.8
24.1
20.8
23.1
21.0
23.2
21.5
23.8
Operation not recommended
19.1
0.65
0.74
32.0
20.9
19.1
0.70
0.64
0.78
0.71
32.6
32.1
20.9
0.69
0.75
33.0
Operation not recommended
20.6
22.5
20.6
22.5
0.67
0.72
0.66
0.71
0.81
0.85
0.79
0.83
33.5
34.3
33.7
34.5
0.67
0.73
0.67
0.72
0.68
0.73
0.68
0.74
0.68
0.73
0.69
0.74
0.91
0.93
0.89
0.91
0.88
0.90
1.04
1.06
1.01
1.03
1.00
1.02
34.4
35.4
34.6
35.6
35.1
36.1
34.0
35.0
34.2
35.1
34.7
35.6
21.9
19.9
22.0
20.4
22.6
18.9
20.9
19.0
21.1
19.5
21.6
20.6
22.8
20.7
22.9
21.2
23.5
19.8
0.76
0.70
0.76
0.71
0.76
0.71
0.77
0.71
0.77
0.72
0.77
0.69
0.75
0.69
0.74
0.70
0.75
0.70
1.36
1.30
1.32
1.29
1.31
1.50
1.53
1.46
1.49
1.45
1.48
1.16
1.18
1.13
1.15
1.12
1.14
1.33
Operation not recommended
18.6
0.75
1.68
30.6
20.6
19.1
0.80
0.75
1.72
1.67
31.4
31.0
21.1
0.81
1.70
31.8
Operation not recommended
18.1
20.1
0.79
0.85
1.90
1.94
29.6
30.3
18.6
20.6
0.79
0.85
1.88
1.92
29.9
30.7
Operation not recommended
18.8
0.85
2.18
29.7
20.4
18.8
20.4
0.90
0.84
0.89
2.24
2.11
2.18
30.3
29.6
30.3
33.5
32.8
33.6
33.2
34.1
31.6
32.4
31.7
32.5
32.1
32.9
33.6
34.5
33.8
34.7
34.3
35.2
32.6
EER
40.1
38.7
41.5
40.5
14.8
14.9
15.2
15.3
12.1
12.2
12.4
12.6
10.2
10.1
10.6
10.5
37.8
36.8
39.3
38.4
34.2
34.5
35.5
35.8
36.4
36.7
29.4
29.7
30.5
30.7
31.3
31.5
21.3
21.9
22.0
22.4
22.6
17.6
17.7
18.2
18.4
18.7
18.9
25.6
25.8
26.6
26.8
27.2
27.5
21.1
HWC
Mbtu/h
0.9
1.0
1.3
1.4
1.0
1.1
0.9
1.0
1.3
1.4
1.2
1.3
-
-
-
-
2.5
3.4
3.6
3.2
2.7
2.4
2.6
2.2
3.4
2.9
3.3
1.9
2.0
1.7
1.9
1.6
1.8
2.5
5.2
5.7
4.8
5.4
4.1
4.5
3.8
4.2
---
---
---
---
6.5
7.0
6.0
6.7
9/16/14
56
T1GX, T2GX SERIES SPECIFICATION CATALOG
Performance Data cont.
Model 038 - Full Load Dual Capacity with Variable Speed ECM or 5-Speed ECM (1250 cfm)
EWT
°F
Flow
Rate
GPM
WPD
PSI FT/HD
Airflow
CFM
HC
MBtu/h
HEATING - EAT 70°F
Power kW
HE
MBtu/h
LAT
°F
COP
HWC
Mbtu/h
Airflow
CFM
TC
Mbtu/h
COOLING - EAT 80/67 °F
SC
Mbtu/h
S/T
Ratio
Power kW
HR
Mbtu/h
EER
HWC
Mbtu/h
5.0
7.0
1.3
2.3
3.0
5.2
20
Operation not recommended
Operation not recommended
30
40
50
60
70
80
90
100
110
120
9.0
5.0
7.0
9.0
5.0
7.0
9.0
5.0
7.0
9.0
5.0
7.0
9.0
5.0
7.0
9.0
5.0
7.0
9.0
5.0
7.0
9.0
5.0
7.0
9.0
5.0
7.0
9.0
5.0
7.0
9.0
3.5
1.2
2.2
3.4
1.2
2.1
3.3
1.2
2.1
3.2
1.1
2.0
3.1
1.1
1.9
3.0
1.1
1.9
2.9
1.0
1.8
2.8
1.0
1.7
2.7
1.0
1.7
2.6
0.9
1.6
2.5
8.1
2.9
5.1
7.9
2.8
4.9
7.6
2.7
4.8
7.4
2.6
4.6
7.2
2.5
4.5
6.9
2.5
4.3
6.7
2.4
4.2
6.5
2.3
4.0
6.2
2.2
3.9
6.0
2.1
3.7
5.8
1050
1250
1050
1250
1050
1250
1050
1250
1050
1250
1250
1050
1250
1050
1250
1050
1250
1050
1250
1050
1250
1050
1250
1050
1250
1050
1250
1050
1050
1250
1050
1250
1050
1250
1050
1250
1050
1250
1050
1250
45.4
47.0
48.1
49.7
49.5
51.2
48.8
50.5
51.8
53.7
53.5
55.3
25.2
26.0
2.21
2.28
17.7
18.2
92.2
3.34
89.3
3.34
28.8
Operation not recommended
2.24
21.1
95.4
3.77
29.6
29.2
2.31
2.26
21.7
21.5
91.9
3.76
95.8
3.79
30.2
2.33
22.3
92.4
3.80
Operation not recommended
32.7
33.7
33.3
34.4
2.32
2.37
2.35
2.40
24.8
25.6
25.3
26.2
98.8
4.12
95.0
4.16
99.4
4.16
95.5
4.21
2.48
2.54
2.55
2.56
2.57
2.57
2.57
2.66
2.66
2.69
2.68
2.36
2.39
2.41
2.44
2.43
2.47
2.47
40.0
40.5
41.8
41.4
42.8
42.1
43.6
44.3
45.8
45.5
47.0
35.3
36.4
36.6
37.8
37.4
38.6
38.7
27.3
28.2
101.1
4.39
96.9
4.46
28.4
102.3
4.45
29.4
98.0
4.53
29.1
103.0
4.51
30.2
98.6
4.59
30.3
104.1
4.60
31.5
99.6
4.72
31.8
105.7
4.68
33.1
100.9
4.80
32.7
106.5
4.74
34.0
101.7
4.88
33.4
107.2
4.80
34.8
102.3
4.96
35.2
109.1
4.88
36.7
103.9
5.04
36.3
110.1
4.95
37.9
104.8
5.14
2.72
2.70
2.83
2.80
2.87
2.83
2.87
2.83
3.00
2.95
3.05
2.97
36.2
110.1
4.89
37.8
104.8
5.10
38.4
112.4
4.98
40.1
106.8
5.20
39.7
113.6
5.05
41.5
107.9
5.31
39.0
113.0
4.97
40.8
107.4
5.23
41.6
115.7
5.06
43.6
109.8
5.33
43.1
117.1
5.14
45.2
111.0
5.46
Operation not recommended
2.9
2.6
3.1
2.8
3.2
2.9
4.1
4.7
4.3
4.8
3.8
4.3
4.0
4.4
4.4
5.0
4.6
3.7
3.4
3.8
3.5
3.9
3.6
4.2
3.4
3.1
3.5
3.2
5.6
5.1
5.9
5.4
5.2
4.8
5.4
5.0
6.0
5.6
6.2
5.8
1050
1250
1050
1250
1050
1250
1050
1250
1250
1050
1250
1050
1250
1050
1250
1050
1250
1050
1250
1050
1250
1050
1250
1050
1250
1050
1050
1250
1050
1250
1050
1250
1050
1250
1050
1250
1050
1250
1050
1250
1050
1250
1050
1250
1050
1250
1050
1250
1050
1250
39.3
40.0
39.5
40.5
40.6
41.3
40.9
41.8
41.3
40.4
42.3
40.7
42.8
39.2
40.9
40.2
41.9
40.6
42.4
39.7
41.8
40.5
42.6
40.9
43.1
39.4
37.5
39.0
38.5
40.0
38.9
40.5
35.8
37.0
36.8
38.2
37.2
38.6
34.6
35.7
35.0
36.1
32.4
33.3
32.7
33.6
30.6
31.1
30.8
31.5
0.70
0.65
0.69
0.68
0.71
0.68
0.72
0.67
0.71
0.69
0.73
0.63
0.67
0.63
0.66
0.66
0.70
0.66
28.7
26.1
29.0
27.5
30.6
26.6
29.6
26.9
29.8
28.0
31.0
25.1
27.9
25.4
28.2
27.1
30.1
25.8
Operation not recommended
25.2
0.64
1.43
44.2
27.5
25.2
0.69
0.64
1.51
1.39
45.1
44.3
27.5
0.68
1.46
Operation not recommended
45.5
26.4
28.8
26.4
28.8
0.65
0.70
0.65
0.69
1.60
1.67
1.55
1.62
46.0
47.0
46.2
47.3
2.09
1.90
1.98
1.85
1.94
2.15
2.23
2.06
2.13
2.01
2.09
1.84
1.94
1.74
1.82
1.69
1.78
2.00
48.4
46.8
49.0
47.1
49.4
46.5
48.5
47.2
49.2
47.4
49.5
46.0
48.4
46.5
48.8
46.7
49.2
46.2
26.1
29.0
26.4
29.2
27.0
30.0
25.5
28.4
25.9
28.7
26.1
28.9
0.70
0.74
0.69
0.73
0.69
0.74
0.71
0.77
0.70
0.75
0.70
0.75
2.34
2.41
2.26
2.33
2.21
2.28
2.53
2.59
2.46
2.52
2.42
2.47
Operation not recommended
25.0
0.72
2.73
43.9
27.7
24.9
0.78
0.71
2.77
2.68
45.2
44.1
27.6
0.76
2.72
Operation not recommended
45.4
24.1
26.7
0.74
0.80
2.99
3.01
42.6
43.5
23.7
26.2
0.73
0.78
2.94
2.97
42.7
43.7
Operation not recommended
23.3
0.76
3.31
41.9
25.3
23.3
25.3
0.81
0.76
0.80
3.39
3.20
3.30
42.7
41.8
42.8
45.4
47.2
46.2
48.0
46.4
48.3
44.4
45.9
45.2
46.8
45.5
47.0
27.4
26.5
28.4
27.7
25.4
24.7
26.4
25.8
19.8
21.3
21.4
22.0
22.1
18.2
18.3
19.5
19.7
20.2
20.3
21.5
21.5
23.3
23.4
24.1
24.2
19.7
16.0
16.1
17.0
17.2
17.6
17.8
14.1
14.3
15.0
15.1
15.4
15.6
12.7
12.9
13.1
13.3
10.8
11.0
11.1
11.3
9.2
9.2
9.6
9.5
7.5
8.1
7.0
7.7
6.2
6.8
5.8
6.4
5.1
5.5
4.8
5.3
2.2
2.9
3.0
2.7
2.4
2.2
2.3
2.0
2.9
2.5
2.8
1.9
2.0
1.8
1.9
1.7
1.8
2.3
-
-
-
-
3.1
3.4
4.4
4.7
3.6
3.8
3.3
3.6
4.1
4.5
3.9
4.3
-
-
-
-
9/16/14
57
T1GX, T2GX SERIES SPECIFICATION CATALOG
Performance Data cont.
Model 049 - Part Load Dual Capacity with Variable Speed ECM or 5-Speed ECM (1350 cfm)
EWT
°F
20
30
40
50
60
70
80
90
100
110
120
Flow
Rate
GPM
5.0
8.0
11.0
5.0
8.0
11.0
5.0
8.0
11.0
5.0
8.0
11.0
5.0
8.0
11.0
5.0
8.0
11.0
5.0
8.0
11.0
5.0
8.0
11.0
5.0
8.0
11.0
5.0
8.0
11.0
5.0
8.0
11.0
1150
1350
1150
1350
1150
1350
1150
1350
1150
1350
1150
1350
1150
1350
1150
1350
1150
1350
1150
1350
1150
1350
1150
1350
1150
1150
1350
1150
1350
1150
1350
1350
1150
1350
WPD
PSI FT/HD
0.9
2.0
2.2
4.6
Airflow
CFM
HC
MBtu/h
HEATING - EAT 70°F
Power kW
HE
MBtu/h
LAT
COP
°F
Operation not recommended
3.4
0.9
1.9
3.3
0.9
1.9
3.2
0.9
1.8
3.1
0.8
1.8
3.0
0.8
1.7
2.9
0.8
1.6
2.8
0.7
1.6
2.7
7.8
2.1
4.4
7.6
2.0
4.3
7.4
2.0
4.2
7.2
1.9
4.0
6.9
1.8
3.9
6.7
1.8
3.8
6.5
1.7
3.6
6.2
1150
1350
1150
1350
1150
1350
2.33
2.27
2.36
2.29
2.35
2.30
2.36
2.31
2.27
2.33
2.28
2.31
2.27
2.28
2.38
2.31
2.23
2.22
2.29
2.26
2.31
2.28
2.27
2.24
42.6
44.4
44.8
46.6
42.1
43.7
45.8
39.5
41.1
41.3
42.9
39.3
40.8
47.6
48.3
50.3
33.7
34.9
36.5
37.9
38.0
39.4
36.4
37.9
23.5
24.3
2.20
2.24
15.9
16.7
88.9 3.12
86.7 3.19
26.5
Operation not recommended
2.20
19.0
91.3 3.52
27.3
2.22
19.7
88.7 3.61
27.1
28.1
2.22
2.25
19.6
20.4
91.8 3.59
89.3 3.66
29.9
Operation not recommended
2.23
22.3
94.1 3.93
31.0
30.9
32.0
2.23
2.25
2.26
23.3
23.2
24.2
91.2 4.06
94.9 4.03
91.9 4.14
31.0
32.0
33.4
34.7
34.7
35.8
2.19
2.19
2.26
2.25
2.28
2.28
23.5
24.5
25.7
27.0
26.9
28.0
94.9 4.14
91.9 4.27
96.9 4.32
93.8 4.51
97.9 4.46
94.6 4.60
26.1
27.3
28.6
30.2
97.1 4.42
93.9 4.61
99.3 4.67
96.0 4.91
30.1
100.6 4.83
31.6
97.0 5.06
28.7
30.2
99.3 4.71
96.0 4.95
31.7
101.8 5.02
33.4
98.2 5.31
33.4
103.3 5.19
35.1
99.4 5.51
31.4
101.6 4.99
33.1
98.0 5.27
34.7
104.3 5.36
36.6
100.4 5.72
36.8
106.1 5.57
38.8
102.0 5.95
34.1
103.9 5.26
35.9
100.0 5.58
37.7
106.8 5.68
39.9
102.7 6.12
40.1
108.9 5.93
42.4
104.5 6.39
0.7
1.7
1.5
2.6
0.7
1.5
2.5
0.7
1.4
2.4
3.5
6.0
1.6
3.4
5.8
1.5
3.3
5.6
Operation not recommended
HWC
Mbtu/h
4.2
3.8
4.3
3.9
4.4
4.0
5.2
4.8
5.4
5.0
5.5
5.1
5.8
5.4
4.8
4.4
4.9
4.5
5.1
4.6
4.5
4.2
4.7
4.2
6.7
6.1
6.9
6.3
7.2
6.7
7.4
6.0
5.5
6.1
5.7
6.5
6.0
6.9
7.7
7.1
Airflow
CFM
TC
Mbtu/h
1150
1350
1150
1350
1150
1350
1150
1350
1150
1350
1150
1350
1150
1350
1150
1350
1150
1350
1150
1350
1150
1350
1150
1350
1150
1350
1150
1350
1150
1150
1350
1150
1350
1150
1350
1350
1150
1350
1150
1350
1150
1350
1150
1350
1150
1350
1150
1350
1150
1350
37.5
38.1
37.7
38.6
39.5
40.7
40.2
41.4
40.6
41.9
38.6
39.8
39.5
40.2
39.8
40.7
40.4
41.7
41.3
42.5
41.5
42.8
37.7
38.8
38.5
39.7
36.3
37.5
36.3
39.0
40.2
39.7
40.9
37.5
38.7
37.3
37.3
38.5
35.2
36.3
36.5
37.6
31.6
32.6
33.1
34.0
29.1
30.1
30.8
31.6
COOLING - EAT 80/67 °F
SC
Mbtu/h
S/T
Ratio
Power kW
HR
Mbtu/h
Operation not recommended
0.60
0.68
0.59
0.67
0.59
0.67
0.59
0.60
0.69
0.60
0.68
0.60
0.68
0.59
0.67
0.59
0.67
0.58
0.66
0.60
0.69
22.5
26.5
22.7
26.7
21.3
25.0
21.5
23.6
27.7
23.7
27.8
22.3
26.2
23.3
27.5
23.5
27.7
23.6
27.7
23.3
27.4
Operation not recommended
21.5
0.57
1.10
41.2
23.5
0.62
1.16
42.0
21.5
23.5
0.57
0.61
1.07
1.12
41.3
42.4
Operation not recommended
23.4
0.59
1.21
43.6
25.6
23.4
25.6
0.64
0.59
0.63
1.27
1.18
1.23
44.6
43.8
44.9
23.3
27.5
23.5
27.6
23.5
27.6
0.58
0.66
0.57
0.65
0.56
0.65
1.56
1.63
1.35
1.42
1.27
1.34
45.7
47.2
45.9
47.4
45.9
47.4
25.4
21.8
0.68
0.58
2.18
2.01
44.8
44.2
25.6
0.66
2.10
45.7
Operation not recommended
22.5
26.5
22.8
26.8
0.64
0.73
0.63
0.71
2.42
2.51
2.33
2.43
43.5
44.9
44.5
45.9
Operation not recommended
21.2
0.67
2.69
40.8
24.9
21.6
25.3
0.76
0.65
0.74
2.80
2.61
2.72
42.2
42.0
43.3
Operation not recommended
20.6
0.71
3.01
39.4
24.2
21.0
24.7
0.80
0.68
0.78
3.14
2.92
3.06
40.8
40.8
42.0
1.87
1.95
1.79
1.87
2.21
2.30
2.10
1.64
1.72
1.57
1.63
2.01
2.10
1.69
1.76
1.50
1.57
1.42
1.49
1.81
1.90
44.1
45.4
44.6
46.1
43.9
45.3
43.5
44.6
46.1
45.0
46.5
44.3
45.8
45.3
46.8
45.3
46.7
45.5
46.9
44.8
46.3
EER
34.1
32.9
35.3
34.5
23.4
23.1
26.8
26.4
28.6
28.2
21.3
21.0
32.6
31.7
33.8
33.1
25.9
25.6
30.5
30.0
32.6
31.9
20.1
19.9
21.5
21.3
16.4
16.3
17.3
23.8
23.5
25.3
25.1
18.6
18.4
17.2
18.6
18.3
14.6
14.4
15.7
15.5
11.7
11.6
12.7
12.5
9.7
9.6
10.6
10.3
HWC
Mbtu/h
9.0
9.8
8.4
9.3
7.1
7.7
6.6
7.3
2.3
2.4
2.1
2.3
1.9
2.2
3.2
3.4
1.6
1.7
1.5
1.6
1.4
1.5
-
-
-
-
4.1
4.4
3.8
4.2
5.9
6.2
5.5
3.0
3.2
2.8
3.1
4.4
4.6
5.9
5.1
5.6
---
---
---
---
11.2
12.1
10.4
11.5
9/16/14
58
T1GX, T2GX SERIES SPECIFICATION CATALOG
Performance Data cont.
Model 049 - Full Load Dual Capacity with Variable Speed ECM or 5-Speed ECM (1550 cfm)
HEATING - EAT 70°F COOLING - EAT 80/67 °F
EWT
°F
Flow
Rate
GPM
6.0
9.0
WPD
PSI FT/HD
1.3
3.0
2.5
5.7
Airflow
CFM
HC
MBtu/h
Power kW
HE
MBtu/h
LAT
°F
COP
Operation not recommended
HWC
Mbtu/h
Airflow
CFM
TC
Mbtu/h
SC
Mbtu/h
S/T
Ratio
Power kW
HR
Mbtu/h
EER
HWC
Mbtu/h
20 Operation not recommended
30
40
50
60
70
80
90
100
110
120
12.0
4.0
6.0
9.0
12.0
3.9
6.0
9.0
12.0
3.7
6.0
9.0
12.0
3.6
6.0
9.0
12.0
3.5
6.0
9.0
12.0
3.4
6.0
9.0
12.0
3.3
6.0
9.0
12.0
3.2
6.0
9.0
12.0
3.1
6.0
9.0
12.0
2.9
6.0
9.0
1.2
2.4
1.2
2.3
1.2
2.2
1.1
2.2
1.1
2.1
1.1
2.0
1.0
2.0
1.0
1.9
1.0
1.8
0.9
1.7
12.0
2.8
9.2
2.9
5.5
8.9
2.8
5.3
8.7
2.7
5.2
8.4
2.6
5.0
8.1
2.5
4.9
7.9
2.5
4.7
7.6
2.4
4.5
7.3
2.3
4.4
7.1
2.2
4.2
6.8
2.1
4.0
6.5
1350
1550
1350
1550
1350
1550
1350
1550
1350
1550
1350
1550
1350
1550
1350
1550
1350
1550
1350
1550
1350
1550
1350
1550
1350
1550
1350
1550
1350
1550
1350
1550
1350
1550
1350
1550
1350
1550
1350
1550
32.6
2.94
22.6
92.4
3.25
33.8
2.98
23.6
90.2
3.32
3.40
3.36
3.46
3.40
3.50
3.42
3.56
3.50
3.60
3.51
3.64
3.54
3.72
3.63
3.74
3.61
3.78
3.66
50.4
52.3
54.7
56.8
57.2
59.3
54.3
56.4
59.0
61.4
62.0
64.5
58.2
60.5
63.3
65.9
66.8
69.6
36.2
Operation not recommended
2.99
26.0
94.8
3.55
37.3
37.1
38.4
3.01
3.01
3.05
27.0
26.8
28.0
92.3
3.63
95.4
3.61
92.9
3.69
47.3
47.3
48.9
46.3
48.0
50.1
52.1
52.2
54.1
40.9
Operation not recommended
3.11
30.3
98.0
3.86
42.3
42.2
3.11
3.13
31.7
31.5
95.3
98.9
3.99
3.96
43.7
42.3
43.7
45.6
3.15
3.12
3.12
3.22
32.9
31.7
33.0
34.6
96.1
99.0
96.1
101.3
4.07
3.98
4.10
4.15
3.20
3.24
3.24
3.26
3.24
3.34
3.30
3.37
3.33
36.4
36.3
37.8
35.2
36.9
38.7
40.8
40.7
42.7
98.3
102.5
99.2
101.8
98.7
104.4
101.1
105.8
102.3
4.34
4.28
4.42
4.16
4.34
4.40
4.62
4.54
4.76
38.8
40.9
42.9
45.2
45.2
47.6
104.5
101.3
107.5
103.9
109.2
105.4
4.34
4.56
4.63
4.90
4.79
5.08
42.2
107.2
4.47
44.5
103.7
4.73
46.7
110.5
4.80
49.4
106.7
5.13
49.6
112.5
4.99
52.4
108.5
5.34
45.6
109.9
4.59
48.1
106.1
4.88
50.6
113.4
4.97
53.6
109.4
5.35
53.9
115.8
5.18
57.1
111.6
5.58
Operation not recommended
5.3
4.8
5.6
5.2
5.6
5.3
8.5
7.9
8.8
8.1
9.0
8.3
7.8
7.2
8.0
7.4
7.2
6.5
7.6
7.0
6.7
6.2
6.9
6.4
6.2
5.7
6.4
5.8
9.6
8.8
9.8
9.1
10.1
9.4
10.7
9.9
11.1
10.2
11.4
10.6
1350
1550
1350
1550
1350
1550
1350
1550
1350
1550
1350
1550
1350
1550
1350
1550
1350
1550
1350
1550
1350
1550
1350
1550
1350
1550
1350
1550
1350
1550
1350
1550
1350
1550
1350
1550
1350
1550
1350
1550
1350
1550
1350
1550
1350
1550
1350
1550
1350
1550
51.5
52.3
51.7
53.0
52.1
53.7
52.6
54.3
53.6
55.2
54.4
56.0
52.5
54.1
53.4
55.0
54.0
55.6
52.9
53.9
53.3
54.5
52.9
54.5
54.0
55.7
49.7
51.3
50.0
51.4
51.1
52.7
47.3
48.8
47.3
48.6
48.6
50.1
44.3
45.6
45.9
47.3
41.2
42.6
43.2
44.4
40.1
40.8
40.4
41.3
29.4
34.6
29.7
34.9
29.9
35.1
Operation not recommended
28.2
0.55
1.80
57.6
30.8
28.2
30.8
0.59
0.54
0.58
1.89
1.74
1.83
58.8
57.7
59.2
34.1
28.9
34.1
29.1
34.3
29.3
34.5
29.4
34.6
Operation not recommended
29.7
0.56
2.01
59.8
32.5
29.7
0.60
0.56
2.11
1.95
61.1
60.0
32.5
28.8
34.0
28.9
0.60
0.54
0.62
0.54
2.04
2.63
2.74
2.27
61.5
61.8
63.9
61.8
0.61
0.53
0.61
0.55
0.63
0.55
0.63
0.55
0.62
2.38
2.14
2.25
2.78
2.90
2.47
2.58
2.34
2.45
63.8
61.7
63.7
62.0
64.0
61.8
63.8
61.9
63.9
0.56
0.64
0.56
0.64
0.56
0.64
2.94
3.07
2.66
2.78
2.54
2.64
62.1
64.2
61.7
63.8
62.2
64.2
28.5
33.5
28.8
33.9
29.1
34.2
27.6
32.4
0.57
0.65
0.58
0.66
0.57
0.65
0.58
0.66
3.11
3.25
2.89
3.01
2.77
2.88
3.30
3.43
27.9
32.9
28.2
33.2
0.59
0.68
0.58
0.66
3.13
3.24
2.99
3.13
57.9
59.6
58.8
60.8
Operation not recommended
27.1
0.61
3.49
56.2
31.9
27.5
0.70
0.60
3.62
3.36
58.0
57.4
60.3
62.3
59.8
61.7
60.5
62.5
58.5
60.5
32.3
0.68
3.51
59.2
Operation not recommended
26.3
30.9
0.64
0.73
3.85
4.01
54.4
56.3
26.8
31.4
0.62
0.71
3.73
3.89
55.9
57.7
Operation not recommended
27.7
0.69
4.35
54.9
30.1
27.7
30.1
0.74
0.69
0.73
4.46
4.21
4.34
56.0
54.8
56.1
28.6
27.6
29.7
29.0
17.7
17.5
19.8
19.5
21.1
20.9
25.4
24.9
18.9
18.7
21.6
21.3
23.0
22.7
26.3
25.6
27.3
26.7
20.1
19.9
23.8
23.4
16.0
15.8
17.3
17.1
18.5
18.3
14.3
14.2
15.1
15.0
16.2
16.0
12.7
12.6
13.7
13.5
10.7
10.6
11.6
11.4
9.2
9.1
9.6
9.5
8.4
9.2
7.8
8.7
4.6
4.9
4.3
4.6
4.0
4.4
3.4
3.7
3.2
3.5
2.6
2.9
3.7
3.9
3.0
3.2
2.8
3.0
-
-
-
-
5.0
5.6
7.3
7.7
5.8
6.2
5.4
5.9
6.8
7.4
6.3
7.0
10.3
11.2
9.6
10.7
---
---
---
---
12.5
13.5
11.6
12.9
9/16/14
59
T1GX, T2GX SERIES SPECIFICATION CATALOG
Performance Data cont.
Model 064 - Part Load Dual Capacity with Variable Speed ECM or 5-Speed ECM (1500 cfm)
EWT
°F
Flow
Rate
GPM
6.0
10.0
20
14.0
6.0
10.0
30
14.0
6.0
10.0
40
14.0
50
60
70
80
90
100
110
120
6.0
10.0
14.0
6.0
10.0
14.0
6.0
10.0
14.0
6.0
10.0
14.0
6.0
10.0
14.0
6.0
10.0
14.0
6.0
10.0
14.0
6.0
10.0
14.0
1.0
2.6
1.0
2.5
2.3
6.0
2.3
5.9
1250
1500
1250
1500
1250
1500
1250
1500
1250
1500
1250
1500
1250
1500
1250
1500
1250
1500
1250
1500
1250
1500
1250
1500
1250
1500
1250
1500
1250
1500
1250
1500
1250
1500
WPD
PSI FT/HD
1.0
2.7
2.4
6.2
5.1
11.8
5.0
4.8
0.9
2.5
4.7
0.9
2.4
4.5
0.9
2.3
4.4
0.9
2.2
4.2
0.8
2.1
4.1
11.5
11.1
2.2
5.7
10.8
2.1
5.5
10.4
2.0
5.3
10.1
2.0
5.1
9.8
1.9
5.0
9.4
Airflow
CFM
HC
MBtu/h
HEATING - EAT 70°F
Power kW
HE
MBtu/h
LAT
°F
COP
1250
1500
1250
1500
1250
1500
Operation not recommended
55.4
55.9
58.5
58.8
59.2
59.5
59.7
59.8
63.7
63.7
64.1
64.0
28.6
29.6
2.73
2.77
19.3
20.1
91.2
88.3
3.07
3.13
31.9
Operation not recommended
2.70
22.7
93.6
3.46
33.1
33.1
34.2
51.1
52.0
53.3
53.9
54.3
54.9
2.74
2.70
2.74
23.7
23.8
24.9
90.4
3.54
94.5
3.58
91.1
3.66
43.8
44.1
45.1
46.6
47.6
48.1
48.9
49.2
50.0
37.4
Operation not recommended
2.79
27.9
97.7
3.92
38.4
38.6
2.80
2.80
28.9
29.1
93.7
98.6
4.02
4.04
39.7
42.2
43.3
42.8
2.81
2.83
2.83
2.88
30.1
32.5
33.7
33.0
94.5
101.2
96.7
101.7
4.14
4.37
4.49
4.36
2.86
2.90
2.88
2.91
2.89
2.96
2.92
2.99
2.95
34.0
34.2
35.3
36.7
37.8
38.0
38.9
39.0
40.0
97.0
102.7
97.8
104.5
99.4
105.6
100.2
106.5
100.9
4.48
4.46
4.59
4.70
4.84
4.76
4.90
4.83
4.98
2.99
2.94
3.04
2.98
3.08
3.01
40.9
107.9
5.01
42.0
102.1
5.18
42.9
109.5
5.13
43.7
103.3
5.31
43.8
110.2
5.17
44.6
103.9
5.35
3.09
3.02
3.14
3.04
3.18
3.09
3.18
3.09
3.23
3.11
3.28
3.16
44.9
111.0
5.26
45.6
104.5
5.43
47.8
113.4
5.47
48.4
106.3
5.66
48.4
113.9
5.46
48.9
106.7
5.65
48.9
114.2
5.51
49.3
106.9
5.67
52.7
117.2
5.79
53.1
109.3
6.01
53.0
117.5
5.74
53.2
109.5
5.94
0.8
2.1
1.8
4.8
3.9
9.1
HWC
Mbtu/h
Airflow
CFM
TC
Mbtu/h
4.9
4.5
5.0
4.6
5.1
4.7
1250
1500
1250
1500
1250
1500
1250
1500
50.0
50.8
50.3
51.5
41.7
43.0
42.2
43.5
8.0
7.4
8.5
7.8
7.6
7.0
7.8
7.2
8.7
8.1
9.0
8.3
6.3
5.8
6.5
6.0
5.9
5.4
6.1
5.7
5.6
5.2
5.7
5.3
5.3
4.9
5.5
5.0
6.8
6.3
7.0
6.5
7.2
6.6
1250
1500
1250
1500
1250
1500
1250
1500
1250
1500
1250
1500
1250
1500
1250
1500
1250
1500
1250
1500
1250
1500
1250
1500
1250
1500
1250
1500
1250
1500
1250
1500
1250
1500
47.2
48.6
47.6
49.0
47.9
49.4
44.3
45.6
44.8
46.1
45.1
46.6
53.1
54.6
51.4
53.0
51.6
53.2
51.9
53.4
51.5
52.5
51.9
53.1
52.8
54.3
52.9
54.5
50.0
51.6
50.3
51.9
50.7
52.2
0.8
1.8
2.0
3.8
4.6
8.7
Operation not recommended
1250
1500
1250
1500
38.7
39.9
39.2
40.4
0.7
1.7
1.9
3.6
4.4
8.4
1250
1500
1250
1500
36.7
37.4
37.0
37.8
COOLING - EAT 80/67 °F
SC
Mbtu/h
S/T
Ratio
Power kW
HR Mbtu/h EER
HWC
Mbtu/h
Operation not recommended
Operation not recommended
30.0
32.8
30.0
32.8
29.7
33.3
29.9
33.7
30.1
33.8
28.5
31.8
28.7
32.2
28.9
32.4
27.2
30.2
27.5
30.6
27.8
26.7
29.0
26.7
29.0
0.60
0.65
1.38
1.45
0.60
1.34
0.64
1.40
0.59
2.19
0.64
2.28
0.59
2.13
0.65
2.22
0.59
2.08
0.65
2.17
0.60
2.49
0.65
2.58
0.60
2.43
0.66
2.52
0.60
2.39
0.65
2.48
0.61
2.80
0.66
2.88
0.61
2.73
0.66
2.83
0.62
2.70
0.73
4.01
0.78
4.11
0.72
3.88
0.77
4.00
54.7
55.8
54.8
56.3
34.3
30.2
34.3
29.8
33.7
30.1
34.0
30.2
34.1
Operation not recommended
30.7
0.60
1.54
56.8
33.6
30.7
0.64
0.59
1.61
1.49
58.0
57.0
33.6
30.0
34.0
30.2
0.63
0.57
0.63
0.57
1.56
1.74
1.83
1.67
58.4
58.7
60.6
58.7
0.63
0.57
0.63
0.58
0.64
0.58
0.64
0.58
0.64
1.75
1.64
1.72
1.96
2.06
1.90
1.99
1.86
1.95
60.5
58.7
60.5
58.1
60.0
58.1
60.0
58.2
60.1
26.0
28.6
26.4
29.0
0.67
0.72
0.67
0.72
3.53
3.60
3.48
3.55
50.7
52.2
51.1
52.5
Operation not recommended
57.5
59.4
57.6
59.5
57.8
59.6
55.7
57.4
55.9
57.6
56.0
57.8
53.8
55.4
54.1
55.8
54.3
30.9
0.66
2.78
56.1
Operation not recommended
26.8
0.64
3.13
52.4
29.6
27.1
0.69
3.22
0.64
3.09
54.0
52.7
30.0
0.69
3.17
54.3
Operation not recommended
50.4
51.4
50.2
51.4
36.3
35.0
37.6
36.7
18.9
18.9
19.6
19.4
20.0
19.9
15.8
15.9
16.4
16.3
16.7
16.8
32.3
31.8
26.2
25.8
27.2
26.8
27.9
27.4
33.5
32.5
34.8
34.0
30.4
29.7
31.7
31.1
22.9
22.6
23.7
23.4
24.3
24.0
13.3
13.4
13.6
13.7
10.9
11.1
11.3
11.4
9.2
9.1
9.5
9.5
-
-
-
-
4.8
5.3
7.4
7.8
5.5
5.9
5.2
5.6
6.9
7.5
6.4
7.1
2.6
2.9
2.5
2.7
1.7
1.9
2.8
3.0
2.0
2.1
1.9
2.0
-
-
-
-
4.0
4.2
3.7
4.0
3.5
3.9
9.0
9.7
8.3
9.2
11.3
12.3
10.5
11.7
14.0
15.2
13.0
14.5
9/16/14
60
T1GX, T2GX SERIES SPECIFICATION CATALOG
Performance Data cont.
Model 064 - Full Load Dual Capacity with Variable Speed ECM or 5-Speed ECM (1800 cfm)
EWT
°F
Flow
WPD
Rate
GPM PSI FT/HD
8.0
1.8
12.0
3.8
4.2
8.8
20
16.0
6.5
15.1
8.0
1.8
12.0
3.7
30
4.1
8.6
16.0
6.4
8.0
1.7
12.0
3.6
40
14.7
4.0
8.3
16.0
6.2
14.2
50
60
70
80
90
100
110
120
8.0
12.0
16.0
8.0
12.0
16.0
8.0
12.0
16.0
8.0
12.0
16.0
8.0
12.0
16.0
8.0
12.0
2.9
16.0
8.0
16.0
8.0
12.0
16.0
1.7
3.5
6.0
1.6
3.4
5.8
1.6
3.3
5.6
1.5
3.2
5.4
1.4
3.0
5.2
1.4
5.0
1.3
12.0
2.8
4.8
1.3
2.7
4.6
3.8
8.1
13.8
3.7
7.8
13.4
3.6
7.5
12.9
3.5
7.3
12.5
3.3
7.0
12.0
3.2
6.8
11.6
3.1
6.5
11.2
3.0
6.3
10.7
Airflow
CFM
HC
MBtu/h
HEATING - EAT 70°F
Power kW
HE
MBtu/h
LAT
COP
°F
HWC
Mbtu/h
Airflow
CFM
TC
Mbtu/h
COOLING - EAT 80/67 °F
SC
Mbtu/h
S/T
Ratio
Power kW
HR
Mbtu/h
1500
1800
1500
1800
1500
1800
1500
1800
1500
1800
1500
1800
1500
1800
1500
1800
1500
1800
1500
1800
1500
1800
1500
1800
1500
1800
1500
1800
1500
1800
1500
1800
1500
1800
1500
1800
1500
1800
1500
1800
Operation not recommended
4.46
4.47
4.51
4.51
4.70
4.67
4.76
4.71
4.12
4.18
4.18
4.24
4.23
4.28
4.39
4.42
4.81
4.76
5.00
4.93
5.05
4.95
5.12
5.00
72.5
74.2
74.4
76.1
76.9
78.7
78.7
80.6
63.1
64.5
66.0
67.4
67.4
69.0
69.9
71.5
81.1
83.2
83.9
85.9
85.0
87.1
87.9
90.2
52.7
53.9
53.5
54.7
56.3
57.4
59.5
60.7
60.5
61.8
39.7
40.7
3.44
3.60
28.0
28.4
94.5
3.39
90.9
3.31
45.8
Operation not recommended
3.46
34.1
98.3
3.89
47.1
46.5
3.68
3.54
34.6
34.4
94.2
3.75
98.7
3.84
47.6
3.71
34.9
94.5
3.76
Operation not recommended
3.68
3.84
3.75
3.88
3.84
3.95
3.91
4.01
3.95
4.05
40.1
40.8
40.7
41.5
43.2
44.0
46.2
47.0
47.0
48.0
102.5
97.7
103.0
98.1
104.7
99.6
106.7
101.2
107.3
101.8
4.19
4.11
4.18
4.13
4.30
4.26
4.46
4.44
4.48
4.47
57.3
58.9
59.0
60.7
60.9
62.7
62.5
64.6
49.1
50.2
51.7
53.0
53.0
54.3
55.0
56.4
64.7
66.9
66.8
69.1
67.7
70.2
70.4
73.1
6.2
5.6
6.5
6.0
6.7
6.1
109.0
4.49
103.2
4.52
110.7
4.62
104.7
4.66
111.6
4.67
105.5
4.72
113.2
4.66
106.8
4.74
114.8
4.77
10.1
108.1
4.86
9.3
115.9
4.83
10.4
109.1
4.95
9.6
117.5
4.80
11.0
110.5
4.94
10.2
118.6
4.85
11.3
111.5
5.02
10.5
9.2
8.5
9.8
9.0
8.7
8.0
9.0
8.3
120.1
4.94
11.7
112.8
5.13
10.8
121.8
4.92
12.4
114.2
5.11
11.4
122.5
4.93
12.7
114.8
5.16
11.8
124.3
5.03
13.1
116.4
5.29
12.2
Operation not recommended
7.8
7.2
8.0
7.4
7.2
6.6
7.4
6.7
8.2
7.5
1500
1800
1500
1800
1500
1800
1500
1800
1500
1800
1500
1800
1500
1800
1500
1800
1500
1800
1500
1800
1500
1800
1500
1800
1500
1800
1500
1800
1500
1800
1500
1800
1500
1800
1500
1800
1500
1800
1500
1800
1500
1800
1500
1800
1500
1800
1500
1800
1500
1800
64.3
65.3
64.6
66.2
68.4
70.6
69.0
71.2
63.2
65.5
63.9
66.2
68.2
70.0
68.9
70.7
69.6
71.4
67.7
69.8
64.5
66.9
58.7
61.3
59.3
61.8
59.9
62.5
66.8
68.1
67.4
68.9
68.7
70.1
69.4
70.8
70.1
71.5
55.2
57.8
55.7
58.4
51.0
53.7
51.5
54.2
51.4
52.4
51.9
53.0
Operation not recommended
0.62
0.66
0.62
0.66
0.65
0.68
0.64
0.68
0.62
0.66
0.62
0.66
0.62
0.66
0.62
0.66
0.65
0.68
0.67
0.70
0.67
0.70
0.67
0.70
42.6
46.3
43.0
46.8
40.8
44.3
41.1
44.7
42.2
45.9
42.6
46.3
43.1
46.8
42.2
45.9
41.6
45.2
39.3
42.7
39.6
43.1
40.1
43.5
41.9
45.8
42.2
45.9
42.6
46.4
43.1
46.8
Operation not recommended
41.0
0.64
2.29
72.1
44.8
41.0
0.69
0.63
2.41
2.22
73.5
72.2
44.8
0.68
2.33
74.1
Operation not recommended
41.9
45.8
0.63
0.67
2.66
2.79
75.9
77.6
0.62
0.66
0.61
0.65
0.61
0.65
0.61
0.65
2.58
2.70
3.00
3.19
2.94
3.12
2.89
3.07
76.2
78.1
78.9
81.0
79.4
81.5
80.0
82.0
3.53
3.75
3.46
3.69
3.89
4.14
3.81
4.06
3.30
3.51
3.23
3.43
3.18
3.38
3.60
3.83
3.75
3.99
4.18
4.45
4.10
4.36
4.03
4.29
80.4
83.4
80.9
83.8
76.5
79.7
76.9
80.0
79.5
81.9
79.9
82.4
80.4
82.9
80.0
82.9
77.3
80.5
72.9
76.5
73.3
76.7
73.7
77.2
Operation not recommended
37.5
0.68
4.47
70.4
40.7
37.9
41.2
0.70
0.68
0.71
4.77
4.39
4.69
74.0
70.7
74.3
Operation not recommended
35.3
0.69
4.84
67.5
38.3
35.7
0.71
0.69
5.17
4.76
71.4
67.7
38.8
0.72
5.08
71.5
Operation not recommended
36.4
39.5
0.71
0.75
5.62
5.76
70.6
72.0
36.4
39.5
0.70
0.75
5.44
5.61
70.4
72.1
EER
HWC
Mbtu/h
28.1
27.1
29.1
28.4
19.4
18.8
19.9
19.3
16.3
15.8
16.8
16.3
20.7
19.9
21.3
20.6
21.9
21.1
18.8
18.2
17.2
16.8
14.0
13.8
14.5
14.2
14.9
14.6
25.1
24.4
26.1
25.5
22.9
22.0
23.6
22.7
24.3
23.3
12.3
12.1
12.7
12.5
10.5
10.4
10.8
10.7
9.2
9.1
9.5
9.4
---
---
---
---
11.1
12.1
10.3
11.5
13.6
14.8
12.7
14.1
7.7
8.1
7.1
7.7
5.7
6.1
5.3
5.8
4.2
4.6
6.1
6.4
4.8
5.1
4.5
4.9
6.6
7.4
9.6
10.2
9.0
9.7
8.3
9.2
4.0
4.2
3.7
4.0
---
---
---
---
3.4
3.8
16.5
17.9
15.3
17.0
9/16/14
61
T1GX, T2GX SERIES SPECIFICATION CATALOG
Performance Data cont.
Model 072 - Part Load Dual Capacity with Variable Speed ECM or 5-Speed ECM (1700 cfm)
EWT
°F
20
30
40
50
60
70
80
90
100
110
120
Flow
Rate
GPM
10.0
13.0
16.0
10.0
13.0
16.0
10.0
13.0
16.0
10.0
13.0
16.0
10.0
13.0
16.0
10.0
13.0
16.0
10.0
13.0
16.0
10.0
13.0
16.0
10.0
13.0
16.0
10.0
13.0
16.0
10.0
13.0
16.0
1400
1700
1400
1700
1400
1700
1400
1700
1400
1700
1400
1700
1400
1700
1400
1700
1400
1700
1400
1700
1400
1700
1400
1700
1400
1700
1400
1700
1400
1700
1400
1700
1400
1700
WPD
PSI FT/HD
2.3
3.6
5.4
8.2
Airflow
CFM
HC
MBtu/h
HEATING - EAT 70°F
Power kW
HE
MBtu/h
LAT
°F
COP
Operation not recommended
5.0
2.3
3.5
4.9
2.2
3.4
4.7
2.1
3.3
4.6
2.1
3.2
4.4
2.0
3.0
4.3
1.9
2.9
4.2
1.9
2.8
4.0
11.6
5.3
8.0
11.3
5.1
7.8
11.0
4.9
7.5
10.6
4.8
7.3
10.3
4.6
7.0
9.9
4.5
6.8
9.6
4.3
6.6
9.3
1400
1700
1400
1700
1400
1700
4.11
4.02
4.15
4.07
4.19
4.12
4.37
4.20
4.43
4.27
4.41
4.23
4.47
4.25
4.53
4.33
4.23
4.11
4.27
4.15
4.34
4.21
4.32
4.17
59.5
62.0
61.1
63.6
62.5
65.0
75.2
77.9
76.0
78.7
77.3
79.8
82.3
85.0
82.8
85.4
65.6
68.2
68.1
70.7
69.3
72.0
71.4
74.0
37.2
39.0
3.74
3.79
24.4
26.0
94.6
2.91
91.2
3.02
49.3
51.5
53.4
55.8
54.2
56.4
55.8
58.1
41.0
Operation not recommended
3.81
28.0
97.1
3.15
43.0
42.8
3.86
3.81
29.8
29.8
93.4
98.3
3.27
3.29
44.8
3.86
31.6
94.4
3.40
Operation not recommended
47.6
49.7
3.92
3.93
34.2
36.3
101.5
97.1
3.56
3.71
3.93
3.94
3.98
3.94
4.02
4.00
4.04
4.02
35.9
38.0
39.8
42.3
40.5
42.7
42.0
44.4
102.6
98.0
105.3
100.4
105.8
100.7
106.9
101.7
3.68
3.83
3.93
4.15
3.95
4.13
4.04
4.24
45.5
48.3
47.0
49.7
48.2
51.0
60.3
63.6
60.9
64.1
62.2
65.4
67.0
70.5
67.3
70.6
51.1
54.2
53.5
56.6
54.5
57.6
56.7
59.8
109.3
4.25
103.8
4.52
110.4
4.32
104.6
4.57
111.4
4.37
105.4
4.63
113.4
4.54
107.2
4.87
115.0
4.67
108.5
5.00
115.8
4.68
109.2
5.01
117.2
4.84
110.3
5.21
119.7
5.04
112.4
5.44
120.3
5.03
112.8
5.40
121.1
5.14
113.5
5.54
124.4
5.39
116.3
5.87
124.7
5.36
116.5
5.78
1.8
4.2
2.7
3.9
1.7
2.6
3.7
1.7
2.5
3.6
6.3
8.9
4.0
6.1
8.6
3.8
5.8
8.2
Operation not recommended
HWC
Mbtu/h
6.0
5.4
6.1
5.6
6.3
5.7
7.5
6.9
7.7
7.1
7.9
7.3
6.8
6.3
7.0
6.4
6.5
5.9
6.7
6.1
7.2
6.6
9.5
8.8
9.8
9.1
10.3
9.5
10.6
9.8
11.0
10.2
8.8
8.1
9.2
8.5
8.3
7.7
8.5
7.9
Airflow
CFM
TC
Mbtu/h
1400
1700
1400
1700
1400
1700
1400
1700
1400
1700
1400
1700
1400
1700
1400
1700
1400
1700
1400
1700
1400
1700
1400
1700
1400
1700
1400
1700
1400
1700
1400
1700
1400
1700
1400
1700
1400
1700
1400
1700
1400
1700
1400
1700
1400
1700
1400
1700
1400
1700
54.1
55.0
54.4
55.7
58.1
59.8
58.3
60.1
58.6
60.4
56.7
57.8
57.2
58.5
59.1
60.9
59.2
61.0
59.4
61.2
53.6
55.2
54.0
56.0
49.7
51.3
50.2
51.8
50.7
52.3
57.1
58.8
57.4
59.1
57.8
59.6
53.4
54.8
46.9
48.5
47.6
49.0
43.7
45.1
44.4
45.7
40.8
41.5
41.1
42.0
COOLING - EAT 80/67 °F
SC
Mbtu/h
S/T
Ratio
Power kW
HR
Mbtu/h
Operation not recommended
36.5
41.3
36.9
41.7
37.0
41.8
36.5
39.8
36.5
41.4
36.8
41.8
36.8
41.8
Operation not recommended
34.6
0.64
1.81
60.3
37.8
34.6
0.69
0.64
1.91
1.76
61.5
60.4
37.8
0.68
1.85
62.0
Operation not recommended
36.5
39.8
0.64
0.69
2.02
2.12
63.6
65.0
0.64
0.68
0.62
0.68
0.62
0.68
0.62
0.68
1.96
2.05
2.28
2.40
2.20
2.32
2.14
2.26
63.9
65.5
66.9
69.1
66.7
69.0
66.7
68.9
0.63
0.69
0.63
0.69
0.63
0.69
2.54
2.66
2.46
2.57
2.41
2.52
0.67
0.72
0.66
0.72
0.68
0.74
0.68
0.74
0.64
0.70
0.64
0.70
0.64
0.70
0.66
0.72
35.7
39.9
35.9
40.2
34.0
37.7
34.3
38.2
36.6
41.2
37.0
41.6
37.2
41.8
35.3
39.5
34.6
38.5
0.68
0.74
3.31
3.38
62.0
63.8
Operation not recommended
33.3
0.71
3.83
60.0
36.9
33.7
37.3
0.76
0.71
0.76
3.88
3.77
3.82
61.7
60.4
62.0
3.04
3.13
2.99
3.08
3.43
3.50
3.36
3.43
2.81
2.91
2.72
2.82
2.68
2.77
3.12
3.21
64.0
65.9
64.2
66.4
61.4
63.2
61.7
63.5
66.7
68.7
66.7
68.7
66.9
69.1
64.1
65.7
66.8
68.9
66.7
68.9
66.8
69.0
Operation not recommended
32.2
0.74
4.30
58.3
35.5
32.7
36.0
0.79
0.74
0.79
4.32
4.24
4.26
59.9
58.9
60.2
Operation not recommended
32.1
0.79
4.71
56.8
34.8
32.1
34.8
0.84
0.78
0.83
4.83
4.56
4.70
58.0
56.7
58.0
EER
HWC
Mbtu/h
29.9
28.8
30.9
30.2
22.8
22.5
23.7
23.4
24.3
24.0
28.0
27.2
29.1
28.5
25.9
25.4
26.9
26.3
27.7
27.1
17.6
17.6
18.0
18.2
14.5
14.6
14.9
15.1
15.3
15.5
20.4
20.2
21.2
20.9
21.6
21.5
17.1
17.1
12.3
10.0
12.5
10.9
12.6
9.3
12.8
10.4
10.2
12.7
10.5
13.8
10.5
11.8
10.7
13.1
8.7
8.6
9.0
8.9
3.2
3.4
3.0
3.2
2.8
3.1
2.3
2.4
2.1
2.3
---
---
---
---
2.0
2.2
8.3
8.8
7.7
8.4
5.8
6.3
5.4
6.0
7.2
8.0
3.9
4.3
6.2
6.6
4.5
4.8
4.2
4.5
---
---
---
---
15.8
17.1
14.6
16.3
9/17/14
62
T1GX, T2GX SERIES SPECIFICATION CATALOG
Performance Data cont.
Model 072 - Full Load Dual Capacity with Variable Speed ECM or 5-Speed ECM (2200 cfm)
EWT
°F
Flow
Rate
GPM
12.0
15.0
20
18.0
12.0
15.0
30
18.0
12.0
15.0
40
18.0
WPD
PSI FT/HD
3.3
7.6
4.7
10.8
6.2
3.2
4.5
14.3
7.4
10.5
6.0
3.1
4.4
5.8
13.9
7.1
10.2
13.5
50
60
70
80
90
100
110
120
12.0
15.0
18.0
12.0
15.0
18.0
12.0
15.0
18.0
12.0
15.0
18.0
12.0
15.0
18.0
12.0
15.0
18.0
12.0
15.0
18.0
12.0
15.0
18.0
3.0
4.3
5.7
2.9
4.1
5.5
2.8
4.0
5.3
2.7
3.9
5.1
2.6
3.7
4.9
2.5
3.6
4.8
2.4
3.5
4.6
2.3
3.3
4.4
6.9
9.9
13.1
6.7
9.6
12.7
6.5
9.2
12.2
6.3
8.9
11.8
6.0
8.6
11.4
5.8
8.3
11.0
5.6
8.0
10.6
5.4
7.7
10.2
Airflow
CFM
HC
MBtu/h
HEATING - EAT 70°F
Power kW
HE
MBtu/h
LAT
°F
COP
HWC
Mbtu/h
Airflow
CFM
TC
Mbtu/h
COOLING - EAT 80/67 °F
SC
Mbtu/h
S/T
Ratio
Power kW
HR
Mbtu/h
EER
HWC
Mbtu/h
1850
2200
1850
2200
1850
2200
1850
2200
1850
2200
1850
2200
1850
2200
1850
2200
1850
2200
1850
2200
1850
2200
1850
2200
1850
2200
1850
2200
1850
2200
1850
2200
1850
2200
1850
2200
1850
2200
1850
2200
Operation not recommended
6.03
5.98
6.11
6.03
6.19
6.09
6.37
6.24
6.44
6.27
6.53
6.34
5.49
5.58
5.56
5.63
5.68
5.72
5.77
5.78
5.85
5.85
5.10
5.28
5.20
5.37
5.26
5.42
5.40
5.50
93.6
96.6
95.8
98.9
98.7
102.0
101.7
105.0
103.1
106.5
106.7
110.2
80.6
83.2
82.4
85.1
85.5
88.2
88.5
91.3
90.8
93.8
68.8
71.1
72.7
75.1
74.0
76.4
77.2
79.7
50.9
52.8
4.60
4.90
35.2
36.1
95.5
3.24
92.2
3.16
57.3
Operation not recommended
4.74
41.2
98.7
3.55
59.3
57.8
59.9
5.04
4.78
5.09
42.1
41.5
42.6
95.0
98.9
95.2
3.45
3.54
3.45
65.0
Operation not recommended
4.97
48.0
102.5
3.83
67.2
65.9
68.2
5.21
5.03
5.26
49.4
98.3
3.78
48.8
103.0
3.84
50.2
98.7
3.80
73.0
76.2
75.0
78.3
77.6
81.2
51.4
104.4
3.95
53.1
99.9
3.94
54.9
106.4
4.10
56.8
101.6
4.10
56.0
107.0
4.12
57.9
102.2
4.13
58.8
108.6
4.19
60.9
103.5
4.24
61.9
110.3
4.30
64.2
105.0
4.37
63.4
111.2
4.35
65.9
105.8
4.43
66.1
112.8
4.41
68.7
107.1
4.52
68.8
114.3
4.49
71.6
108.4
4.63
70.9
115.4
4.55
73.9
109.5
4.70
116.9
110.7
4.55
4.73
118.0
4.60
111.6
4.81
119.4
4.68
112.9
4.91
79.9
120.9
4.68
83.7
114.2
4.93
81.1
121.6
4.69
85.0
114.8
4.97
84.4
123.4
4.79
88.6
116.4
5.09
Operation not recommended
7.9
7.1
8.3
7.6
8.6
7.8
9.2
8.4
9.5
8.6
9.9
9.2
10.3
9.4
10.6
9.7
11.1
10.3
11.5
10.6
11.8
10.9
12.5
11.6
12.9
11.9
13.3
12.3
14.1
13.0
14.5
13.4
15.0
13.8
15.8
14.7
16.3
15.1
16.8
15.6
1850
2200
1850
2200
1850
2200
1850
2200
1850
2200
1850
2200
1850
2200
1850
2200
1850
2200
1850
2200
1850
2200
1850
2200
1850
2200
1850
2200
1850
2200
1850
2200
1850
2200
1850
2200
1850
2200
1850
2200
1850
2200
1850
2200
1850
2200
1850
2200
1850
2200
70.4
71.5
70.8
72.5
72.9
74.3
73.5
75.1
74.6
76.2
75.4
76.9
76.2
77.7
74.0
75.5
74.7
76.2
75.5
77.1
73.3
74.9
74.1
75.6
74.9
76.4
69.6
71.1
70.3
71.8
71.1
72.5
65.9
67.3
66.6
67.9
67.3
68.7
63.2
64.5
63.9
65.2
59.8
61.0
60.4
61.7
55.6
56.6
56.1
57.3
Operation not recommended
Operation not recommended
43.1
47.1
43.1
47.1
50.0
45.8
50.0
46.8
50.6
47.3
51.0
48.0
51.6
48.6
52.5
49.4
53.1
48.6
52.3
49.1
52.8
49.6
53.4
47.6
51.7
48.1
52.3
49.1
52.8
48.1
52.0
0.61
0.66
0.61
0.65
0.67
0.64
0.68
0.64
0.68
0.64
0.68
0.65
0.69
0.65
0.69
0.65
0.69
0.66
0.70
0.66
0.70
0.66
0.70
0.67
0.71
2.57
2.71
2.50
2.62
3.30
0.62
3.06
0.67
3.20
3.68
3.91
3.60
3.83
3.54
3.77
4.01
4.26
3.93
4.17
3.86
4.11
4.34
4.62
4.25
4.52
4.18
4.45
4.63
4.92
0.67
4.53
0.71
4.82
0.67
4.46
0.71
4.75
79.2
80.8
79.3
81.4
Operation not recommended
45.8
0.63
3.15
83.6
85.5
83.9
86.0
45.0
48.9
45.4
49.3
0.68
4.92
0.73
5.23
0.68
4.81
0.73
5.13
82.7
85.2
83.0
85.4
46.3
49.8
0.69
4.73
0.73
5.04
83.5
85.9
Operation not recommended
44.4
0.70
5.29
81.2
48.0
45.1
0.74
5.63
0.71
5.20
83.7
81.6
48.5
0.74
5.53
84.1
Operation not recommended
43.5
46.8
43.9
47.2
0.73
0.77
0.73
0.77
5.76
6.13
5.66
6.02
79.4
81.9
79.8
82.2
Operation not recommended
41.7
0.75
6.52
77.9
45.3
41.7
45.3
0.80
0.74
0.79
6.69
6.31
6.51
79.4
77.6
79.5
88.1
90.5
88.7
91.1
88.2
90.6
88.6
91.0
89.1
91.6
87.2
89.6
87.7
90.0
88.3
90.6
87.7
90.1
85.4
87.9
85.8
88.2
86.3
88.7
27.4
26.4
28.4
27.7
12.0
11.5
12.3
11.8
10.4
10.0
10.7
10.2
8.5
8.5
8.9
8.8
---
---
---
---
12.2
13.2
11.3
12.5
14.9
16.1
13.8
15.3
23.2
22.5
24.0
23.5
19.0
18.3
19.6
18.7
16.9
16.2
17.4
16.7
17.9
17.2
20.3
19.5
20.9
20.1
21.5
20.6
18.4
17.7
15.0
14.4
15.5
14.9
16.0
15.3
13.4
10.5
12.9
11.1
13.8
9.8
13.3
10.6
14.2
9.1
13.6
10.1
8.4
8.9
7.8
8.4
7.2
8.0
6.6
7.0
6.2
6.7
4.9
5.3
4.6
5.1
5.7
6.4
3.7
4.2
5.3
5.6
4.3
4.6
4.0
4.4
---
---
---
---
18.0
19.5
16.7
18.5
9/17/14
63
T1GX, T2GX SERIES SPECIFICATION CATALOG
Wiring Schematics
Variable Speed ECM
Ext Pump
1/2 hp Total
208-230/60/1
Pump
G
Pump
Dual Capacity
Units Only
Ultra Tech
NO
RCP
CS
CC Violet(2)
Black(1)
Thermostat
R
C
Y1
Y2
G
L1
W
O
CR1
Blue
Blue
CCHI
CC
CC-GND
P1
R
C
Y1
Y2
W
O
G
LO
7
8
5
6
1
2
3
4
COM
NOTE 9
NOTE 2
C
SL1 In
SL1 Out
Optional
Remote Unit
Without
Loop Pump
NOTE 10
Optional
Electronic
Air-Filter
P2
Shut
Down
C
C
SL1 In
SL1 Out
Not
Used
NOTE 3
P3
Acc Com
Acc NC
Acc NO
1
2
3
6
7
4
5
1 2 3
P4
2
PB1
2
1
1
Blue
NOTE 6
DHW
Pump
Pink
Yellow(8)
Gray(9)
Blue
Blue
Fused L2 Fused L2
CR2
NO
COM
NO
CR3
Unit Power
208-230/60/1
G
NC
COM
240V L2
NO
Microprocessor
Logic Control
(DC Voltage)
Run
Capacitor
Blue
Compressor
S
R
C
Green/Yellow
NOTE 13
Black Red
Blue
Black
Pink
Tan
(16)
T2
CC
L2 L1
T1
Black/White(11)
Gray/White(10)
NOTE 4
2
1
NOTE 1
3
PB2
Orange(14) Brown(15)
NC
CR4
Black(7)
COM
240V L2
F1-10A 240V
ECM
Air Flow
Settings
NOTE 7
SW1 On
7
8
9
10
11
12
4
5
6
1
2
3
SW2 On SW3
5
6
7
8
1
2
3
4
Test / Norm
Loop / Well
Fan / Comp
Dehum / Norm
No Htg3 / Htg3
Inputs / Norm
Outputs / Norm
Pulse L / Constant L
On
1 2 Speed / 1 Speed
2
3
4
Normal / Finish on 2 nd (Note 11)
No RPM / RPM
Old EH & ECM / Normal (Note 8)
5 G Series / NA
Main Logic PCB
Fused L1
240V L1
R
11
16
10
9
6
15
2
1
3
5
14
12
13
7
4
8
P6
C
12
5
13
3
8
1
6
7
14
9
2
10
11
P5
4
Tan Not Used
Orange
Orange
Not Used
Not Used
Pink
Pink
Yellow
Yellow
Blue
Blue
Black
Black
Not Used
Black
Violet
Yellow
Blue
Gray
Brown
Not Used
Not Used
Orange
Blue
Pink
White
Tan
Red
Not Used
RV
T
T
Black
Red
208V
Blue
240V
Run Winding
Active
Start
Common
Transformer
24V
Yellow Black/White
CO
HWL
FP
LP
HP
SW4
R
R
R
R
R
G
Y
R
Diagnostic Modes
LED Normal Display Mode Current Fault Status Inputs Outputs Outputs2
Drain
Water Flow
High Press
Low Press / CA
Air Flow / Fan
Status
DHW Limit
DHW off
Field Selection Dips - #1 On, #6 On, #7 On
Drain pan overflow Lockout
FP thermistor (loop<15°F,well<30°F) Lockout
High Pressure
Low Pressure / Comfort Alert
ECM2 RPM < 100 rpm Lockout
Microprocessor malfunction*
HWL thermistor > 130°F
DHW pump switch off
*Green LED not flashing
#1 Off, #6 On, #7 On
Drain pan overflow
FP thermistor (loop<15°F, well<30°F)
High Pressure
#6 Off, #7 On
Y1
Y2
O
Low Pressure / Comfort Alert
ECM2 RPM < 100 rpm
Not Used
HWL thermistor > 130°F
DHW pump switch off
SL2
--
G
W
SL1
#6 On, #7 Off
Compressor Lo
Compressor Hi
RV
FAN
DHW Pump
Loop Pump 1
Loop Pump 2
--
#6 Off, #7 Off
Blower Lo
Blower Med
Blower Hi
Aux Heat #1
Aux Heat #2
AuxHeat #3
Aux Heat #4
--
IntelliStart
Notes:
1 – Switch Blue and Red wires for 208V operation.
2 - Connection of remote unit that does not have a loop pump for slave operation.
3 - 24V Accessory relay (see SW2 - 3 for description of operation)
4 - The blk/wh and gray/wh wires are removed when Aux Heat is installed.
5 – Use manufacturer’s part number 19P592-01 (jumper bar assembly)
when single source power is required.
6 - DHW pump only in models with hot water generation option.
7 - Air Flow Configuration Example: SW1 configured for dip 1 as low, dip 3 as medium, and dip 5 as high
Speed ECM2 fan
8 – SW3-4 should be in the OFF position when using ECM motor and 17P501A01 electric heat board and
should be ON when using ECM2 with 17P514A01 electric heat board
9 – SW2-8 must be in the OFF position for pulsed “L” lockout signal and in the ON position for constant
“L” lockout signal.
10 - When optional electronic air-filter is installed, power for the electronic air-filter is provided by P2-2 and
24 VAC.
11 – This Switch allows the unit to down stage with the t-stat when OFF and finish on second stage when
ON.
12 – Low voltage wiring CLASS 2.
13 – Ground wire only on units with aluminum air coils.
64
T1GX, T2GX SERIES SPECIFICATION CATALOG
Wiring Schematics cont.
Variable Speed ECM cont.
97P847-01 7/27/2015
CSA installed units only
Local codes may require a single source of power supply
Single Disconnect Power
208-230/60/1
Breaker box furnished by installer
L1 L2
L1
Circuit Breakers
L2 L1 L2
Aux Elect Power
208-230/60/1
Unit Power
208-230/60/1
Brown
Orange
Green
1 2 3 4 5 P11
ECM
Blower
Motor
3 15 16 10 8 P12
To PB2
Green
1 2 3 4 5 P11
Connects to variable speed ECM motor only
With optional EA Series 10kW Auxiliary Electric Heat shown
Place auxiliary heat schematic from kit here
Brown
Orange
Blue
Violet
Green
P9
1
2
3
5
4
Brown
Orange
208-230/60/1
L2
L1 G
1 - Use copper or aluminum conductors.
2 – When Auxiliary Heat is installed the BLK/WHT wire from CC-L1 to PB2-2 and the GRY/WHT wire from CC-L2 to PB2-1 must be removed (located in the heat pump control box).
3 – Jumpers wires are Factory Installed, and are
Required for auxiliary heat operation.
4 – Low voltage wiring CLASS 2.
Black
Gray
TB
Black
Gray
G
G
ER
3
N
O G
C 1 2
ER
4
3
P2
4
G
C
EA Series
PCB
1 2 3
N
O
P1
4
ER
1
ER
2
N
O
N
O
Gray
Black
P10 from unit’s control box connects to P2
NOTE 3
HE1
Gray
TS1
HE2
Gray
Black
TS2
Gray
Black
Black
P10
1
2
3
4
5
6
Legend
L1
Breaker
Factory Low voltage wiring
Factory Line voltage wiring
Field low voltage wiring
Field line voltage wiring
Optional block
DC Voltage PCB traces
Internal junction
Quick connect terminal
Wire nut
Field wire lug
Ground
Relay Contacts-
N.O., N.C.
Fuse
T
G
Thermistor
Light emitting diode - Green
Relay coil
Capacitor w/ bleed resistor
Switch - Condensate overflow
Switch - High pressure
Switch - Low pressure
P
2 3 1
Switch -Hot Water On/Off
Polarized connector
CC -
CO -
CR1 -
CR2-
CR3 -
CR4 -
CS -
F1 and F2 -
FP -
HE -
HP -
ER1 to ER4 -
Compressor Contactor
Condensate overflow sensor
DHW pump relay
Loop pump relay
PSC Fan Speed Relay
PSC Fan Power Relay
Compressor Solenoid
Fuses
Freeze protection sensor
Heater element
High pressure switch
Aux heat stage relays
LP -
PB1, PB2 -
PS -
RV -
SW1 -
SW2 -
SW3 -
SW4 -
TS -
HWL -
SC -
SR -
Low pressure switch
Power blocks
Power strip
Reversing Valve coil
DIP package 12 position
DIP package 8 position
DIP package 5 position
Hot water pump enable switch
Thermal limit switch
Hot water limit sensor
Start Contactor
Start Relay
Logic Board - Physical Layout
P4
1 2 3
F1 F1
N.O.
N.O.
N.C.
N.O.
N.O.
CR1- DHW
Pump
CC-GND
CC
CCLO
CCHI
C
C
R
R
1 2 3
P1
4
R C Y1 Y2
5
W
6
O
SW1
Off On
7
8
5
6
3
4
1
2
9
10
11
12
7
G L
8
CR2- Loop
Pump
CR3-
Logic Board
Com Com
Microprocessor
SW2
Off On
7
8
5
6
3
4
1
2
SW3
Off On
3
4
1
2
5
1
Shut
Down
2
C
3
P2
C
4
SL1
IN
5
SL1
Out
6
SL2
IN
7
SL2
Out
CR4-
1
ACC
NO
9
10
11
12
13
14
15
2
3
4
5
6
7
16
8
8
9
1
2
10
11
12
13
14
3
4
5
6
2
P3
7
1
ACC
NC
3
ACC
COM
P6
P5
65
T1GX, T2GX SERIES SPECIFICATION CATALOG
Wiring Schematics cont.
Variable Speed ECM & IntelliStart
Ext Pump
1/2 hp Total
208-230/60/1
Pump
G
Pump
Dual Capacity
Units Only
Ultra Tech
NO
RCP
CC Violet(2)
Black(1)
Thermostat
R
C
Y1
Y2
W
O
G
L1
CS
CR1
Blue
Blue
CCHI
CC
CC-GND
P1
R
C
Y1
Y2
W
O
G
LO
4
5
6
7
8
1
2
3
COM
NOTE 9
NOTE 2
C
SL1 In
SL1 Out
Optional
Remote Unit
Without
Loop Pump
NOTE 10
Optional
Electronic
Air-Filter
P2
Shut
Down
C
C
SL1 In
SL1 Out
Not
Used
NOTE 3
P3
Acc Com
Acc NC
Acc NO
1
2
3
6
7
4
5
1 2 3
P4
2
PB1
2
1
1
Blue
NOTE 6
DHW
Pump
Pink
Yellow(8)
Gray(9)
Blue
Blue
Fused L2 Fused L2
CR2
NO
COM
NO
CR3
Unit Power
208-230/60/1
G
NC
COM
240V L2
NO
CR4
Black(7)
Microprocessor
Logic Control
(DC Voltage)
Run
Capacitor
Blue
Compressor
S
R
C
Green/Yellow
NOTE 13
Black Red
Blue
Black
Pink
Tan
(16)
T2
CC
T1
L2 L1
Black/White(11)
Gray/White(10)
NOTE 4
1
2
NOTE 1
3
PB2
Orange(14) Brown(15)
Black
NC
COM
240V L2
F1-10A 240V
ECM
Air Flow
Settings
NOTE 7
SW1 On
8
9
10
11
12
6
7
4
5
1
2
3
SW2 On SW3
5
6
7
8
1
2
3
4
Test / Norm
Loop / Well
Fan / Comp
Dehum / Norm
No Htg3 / Htg3
Inputs / Norm
Outputs / Norm
Pulse L / Constant L
On
1
2
3
4
2 Speed / 1 Speed
Normal / Finish on 2 nd (Note 11)
No RPM / RPM
Old EH & ECM / Normal (Note 8)
5 G Series / NA
Main Logic PCB
Fused L1
240V L1
R
11
16
6
15
10
9
2
1
3
5
14
12
13
7
4
8
P6
C
12
5
13
3
8
1
6
7
14
9
2
10
11
4
P5
Tan Not Used
Orange
Orange
Not Used
Not Used
Pink
Pink
Yellow
Yellow
Blue
Blue
Black
Black
Not Used
Black
Violet
Yellow
Blue
Gray
Brown
Not Used
Not Used
Orange
Blue
Pink
White
Tan
Red
Not Used
RV
T
T
Red
208V
Blue
240V
Run Winding
Active
Start
Common
Transformer
24V
Yellow Black/White
CO
HWL
FP
LP
HP
SW4
R
R
R
R
R
G
Y
R
LED Normal Display Mode Current Fault Status
Diagnostic Modes
Inputs Outputs
Drain
Water Flow
High Press
Low Press / CA
Air Flow / Fan
Status
Field Selection Dips - #1 On, #6 On, #7 On
Drain pan overflow Lockout
FP thermistor (loop<15°F,well<30°F) Lockout
High Pressure
Low Pressure / Comfort Alert
ECM2 RPM < 100 rpm Lockout
Microprocessor malfunction*
DHW Limit
DHW off
HWL thermistor > 130°F
DHW pump switch off
*Green LED not flashing
#1 Off, #6 On, #7 On
Drain pan overflow
FP thermistor (loop<15°F, well<30°F)
High Pressure
#6 Off, #7 On
Y1
Y2
O
Low Pressure / Comfort Alert
ECM2 RPM < 100 rpm
Not Used
HWL thermistor > 130°F
DHW pump switch off
G
W
SL1
SL2
--
#6 On, #7 Off
Compressor Lo
Compressor Hi
RV
FAN
DHW Pump
Loop Pump 1
Loop Pump 2
--
Outputs2
#6 Off, #7 Off
Blower Lo
Blower Med
Blower Hi
Aux Heat #1
Aux Heat #2
AuxHeat #3
Aux Heat #4
--
IntelliStart
Notes:
1 – Switch Blue and Red wires for 208V operation.
2 - Connection of remote unit that does not have a loop pump for slave operation.
3 - 24V Accessory relay (see SW2 - 3 for description of operation)
4 - The blk/wh and gray/wh wires are removed when Aux Heat is installed.
5 – Use manufacturer’s part number 19P592-01 (jumper bar assembly)
when single source power is required.
6 - DHW pump only in models with hot water generation option.
7 - Air Flow Configuration Example: SW1 configured for dip 1 as low, dip 3 as medium, and dip 5 as high
Speed ECM2 fan
8 – SW3-4 should be in the OFF position when using ECM motor and 17P501A01 electric heat board and
should be ON when using ECM2 with 17P514A01 electric heat board
9 – SW2-8 must be in the OFF position for pulsed “L” lockout signal and in the ON position for constant
“L” lockout signal.
10 - When optional electronic air-filter is installed, power for the electronic air-filter is provided by P2-2 and
24 VAC.
11 – This Switch allows the unit to down stage with the t-stat when OFF and finish on second stage when
ON.
12 – Low voltage wiring CLASS 2.
13 – Ground wire only on units with aluminum air coils.
66
T1GX, T2GX SERIES SPECIFICATION CATALOG
Wiring Schematics cont.
Variable Speed ECM & IntelliStart cont.
Brown
Orange
Green
1 2 3 4 5 P11
ECM
Blower
Motor
3 15 16 10 8 P12
P10
1
2
5
6
3
4
Blue
Violet
3
5
4
P9
1
With optional EA Series 20kW Auxiliary Electric Heat Shown
208-230/60/1
Note 2
208-230/60/1
1 - Use copper or aluminum conductors.
Circuit 2 Circuit 1
2 - Use manufacturer’s part number 19P592-01 (jumper bar assembly) when single source power is required.
G
L2 L1 L2 L1 G 3 – When Auxiliary Heat is installed the BLK/WHT wire from CC-L1 to PB2-2 and the GRY/WHT wire from CC-L2 to PB2-1 must be removed (located in the heat pump control box).
4 – Jumpers wires are Factory Installed, and are required for auxiliary heat operation.
2 5 – Low voltage wiring CLASS 2.
Brown
Orange
Yellow
Yellow
Gray
Gray
EHC1
Gray
Yellow
HE1 TS1
HE3
TS3
Gray
Yellow
EHC2
Black
Pink
Pink
Black
HE2
HE4
TS2
TS4
Green
1 2 3 4 5 P11
Connects to variable speed ECM motor only
Place auxiliary heat schematic from kit here
Legend
Factory Low voltage wiring
Factory Line voltage wiring
Field low voltage wiring
Field line voltage wiring
Optional block
DC Voltage PCB traces
Internal junction
Quick connect terminal
G
EHC
EHR
EHC
Light emitting diode - Green
208-230V Relay coil
24VDC Relay coil
Electric Heat Contactor
TS Thermal Limit Switch P
1 2 3
Polarized connector
L1 Field wire lug
Ground
PB - Power block
HE Heater element
N.O., N.C.
ER1 to ER4 - Aux heat stage relays
Breaker
Pink
Black
Black
Pink
DO NOT REMOVE JUMPER WIRES
PLACE AUXILIARY HEAT SCHEMATIC ON UNIT SCHE
Black
Gray
Yellow
G
G
ER1
NO
Gray
EHC1
ER2
Black
NO
ER3
Yellow
EHC2
NO G
ER4
Pink
G NO
C 1 2 3
P2
4
C
EA Series PCB
P1
1 2 3 4
Pink
P10 from unit’s control box connects to P2
Note 4
Logic Board - Physical Layout
CSA installed units only
Local codes may require a single source of power supply
Single Disconnect Power
208-230/60/1
Breaker box furnished by installer
L1 L2
L1
Circuit Breakers
L2 L1 L2
Aux Elect Power
208-230/60/1
Unit Power
208-230/60/1
Legend
L1
Breaker
Factory Low voltage wiring
Factory Line voltage wiring
Field low voltage wiring
Field line voltage wiring
Optional block
DC Voltage PCB traces
Internal junction
Quick connect terminal
Wire nut
Field wire lug
Ground
Relay Contacts-
N.O., N.C.
Fuse
T
G
Thermistor
Light emitting diode - Green
Relay coil
Capacitor w/ bleed resistor
Switch - Condensate overflow
Switch - High pressure
Switch - Low pressure
P
2 3 1
Switch -Hot Water On/Off
Polarized connector
CC -
CO -
CR1 -
CR2-
CR3 -
CR4 -
CS -
F1 and F2 -
FP -
HE -
HP -
ER1 to ER4 -
Compressor Contactor
Condensate overflow sensor
DHW pump relay
Loop pump relay
PSC Fan Speed Relay
PSC Fan Power Relay
Compressor Solenoid
Fuses
Freeze protection sensor
Heater element
High pressure switch
Aux heat stage relays
LP -
PB1, PB2 -
PS -
RV -
SW1 -
SW2 -
SW3 -
SW4 -
TS -
HWL -
SC -
SR -
Low pressure switch
Power blocks
Power strip
Reversing Valve coil
DIP package 12 position
DIP package 8 position
DIP package 5 position
Hot water pump enable switch
Thermal limit switch
Hot water limit sensor
Start Contactor
Start Relay
F1 F1
P4
1 2 3
N.O.
N.O.
N.C.
N.O.
N.O.
CR1- DHW
Pump
CC-GND
CC
CCLO
CCHI
C
C
R
R
1 2 3
P1
4 5
R C Y1 Y2 W
6
O
SW1
Off On
7
8
5
6
3
4
1
2
9
10
11
12
7
G L
8
CR2- Loop
Pump
CR3-
Logic Board
Com Com
Microprocessor
SW2
Off On
1
Shut
Down
2
C
7
8
5
6
3
4
1
2
SW3
Off On
3
4
1
2
5
3
P2
C
4
SL1
IN
5
SL1
Out
6
SL2
IN
7
SL2
Out
CR4-
1
ACC
NO
9
1
10
11
12
13
14
15
2
3
4
5
6
7
16
8
8
9
1
2
10
11
12
13
14
3
4
5
6
P3
2
7
ACC
NC
3
ACC
COM
P6
P5
67
T1GX, T2GX SERIES SPECIFICATION CATALOG
Wiring Schematics cont.
5-Speed ECM
NOTE 11
Black
Blue
Red
Tan
Gray
4
5
2
3
C
1
5 Speed
ECM
Blower
Motor
Compressor
R
S
NOTE 15
Green/Yellow
C
L N G
Blue Red Black
NOTE 12
Ext Pump
1/2 hp Total
208-230/60/1
Pump Pump
G
2
PB1
2
1
1
Unit Power
208-230/60/1
Run
Capacitor
Tan
(16)
CC
G
L2 L1
NOTE 13
Thermostat
R
C
Y1
Y2
W
O
G
L1
NOTE 9
Thermostat to TB Connection Table
Thermostat
R
C
Y1
Y2
W
O
G
L1
CSA installed units only
Local codes may require a single source of power supply
Single Disconnect Power
208-230/60/1
Breaker box furnished by installer
L1 L2
L1 L2
TB
R
C
Y1
Y2
W1
O
G
L
Circuit Breakers
L1 L2
TB
R
C
Y1
Y2
W1
O
G
L
S
X1
5 SPEED ECM MOTOR LOW VOLTAGE CONNECTIONS SS
Model TAP-1 TAP-2 TAP-3 TAP-4 TAP-5
BLUE GRAY
48
60
70
22
30
36
42
BLUE
BLUE
BLUE
BLUE
BLUE
BLUE
RED
RED
RED
RED
GRAY
RED
GRAY
GRAY
RED
RED
GRAY
GRAY
GRAY
5 SPEED ECM MOTOR LOW VOLTAGE CONNECTIONS DC
Model TAP-1 TAP-2 TAP-3 TAP-4 TAP-5
26
38
49
64
72
BLUE
BLUE
BLUE
BLUE
BLUE
RED
RED
RED
RED
RED
TAN
TAN
TAN
GRAY
GRAY
GRAY
GRAY TAN
TAN GRAY
Dual Capacity
Units Only
Ultra Tech
CS
RCP
CC Violet(2)
Black(1)
12V
12V
12V
12V
Yellow
Black
Red
Tan
Gray
White
Blue
Orange
NO
Blue
CR1
Blue
Blue
CCHI
CC
CC-GND
P1
R
C
Y1
Y2
W
O
G
LO
3
4
1
2
5
6
7
8
COM
Blue
NOTE 6
Blue
DHW
Pump
Pink
Yellow(8)
Gray(9)
Fused L2
CR2
NO
COM
Fused L2
NO
CR3
X2
Aux Elect Power
208-230/60/1
Unit Power
208-230/60/1
Notes:
1 – Switch Blue and Red wires for 208V operation.
2 - Connection of remote unit that does not have a loop pump for slave operation.
3 - 24V Accessory relay (see SW2 - 3 for description of operation)
4 - The blk/wh and gray/wh wires are removed when Aux Heat is installed.
5 – Use WaterFurnace part number 19P592-01 (jumper bar assembly)
when single source power is required.
6 - DHW pump only in models with hot water generation option.
7 – This Switch allows the unit to down stage with the t-stat when OFF and finish on second stage when
ON.
8 – SW3-4 should be in the OFF position when using the 17P501A01 electric heat board and
should be ON when using the 17P514A01 electric heat board .
9 – SW2-8 must be in the OFF position for pulsed “L” lockout signal and in the ON position for constant
“L” lockout signal.
10 - When optional electronic air-filter is installed, power for the electronic air-filter is provided by P2-2 and
24 VAC.
11- Y2 TAN wire not connected on Single Speed units. Wire secured at blower.
12- Refer to 5 Speed ECM Motor Low Voltage Connection Table for factory settings.
13- Refer to Thermostat/TB Connection table for thermostat connections to unit.
14 – Low voltage wiring CLASS 2.
15 – Ground wire only on units with aluminum air coils.
NOTE 2
C
SL1 In
SL1 Out
Optional
Remote Unit
Without
Loop Pump
NOTE 10
Optional
Electronic
Air-Filter
SW4
P2
Shut
Down
C
C
SL1 In
SL1 Out
Not
Used
6
7
4
5
NOTE 3
P3
Acc Com
Acc NC
Acc NO
1
2
3
1 2 3
P4
R
R
R
R
R
G
Y
R
LED
Drain
Water Flow
High Press
Low Press / CA
Air Flow
Status
DHW Limit
DHW off
ECM
Air Flow
Settings
SW1 On
8
9
10
11
12
3
4
5
1
2
6
7
SW2 On SW3
On
1 Test / Norm
2
3
4
Loop / Well
Fan / Comp
5
6
Dehum / Norm
No Htg3 / Htg3
Inputs / Norm
7
8
Outputs / Norm
Pulse L / Constant L (NOTE 9)
1 2 Speed / 1 Speed
2
3
Normal / Finish on 2
No RPM / RPM nd (Note 7)
4 Electric Heat / Normal (Note 8)
5 G Series / NA
Main Logic PCB
*Green LED not flashing
240V L2
NC
COM
NO
CR4
Black(7)
Microprocessor
Logic Control
(DC Voltage)
NC
COM
240V L2
F1-10A 240V
Black/White(11)
Gray/White(10)
Orange(14) Brown(15)
Fused L1
240V L1
Diagnostic Modes
Normal Display Mode Current Fault Status Inputs Outputs Outputs2
Field Selection Dips - #1 On, #6 On, #7 On #1 Off, #6 On, #7 On
Drain pan overflow Lockout
WCL thermistor (loop<15°F,well<30°F) Lockout
Drain pan overflow
WCL thermistor (loop<15°F,well<30°F)
#6 Off, #7 On
Y1
Y2
High Pressure
Low Pressure / Comfort Alert
ECM2 RPM < 100 rpm Lockout
Microprocessor malfunction*
HWL thermistor > 130°F
DHW pump switch off
High Pressure
Low Pressure / Comfort Alert
ECM2 RPM < 100 rpm
Not Used
HWL thermistor > 130°F
DHW pump switch off
O
G
W
SL1
SL2
--
#6 On, #7 Off
Compressor Lo
Compressor Hi
RV
FAN
DHW Pump
Loop Pump 1
Loop Pump 2
--
#6 Off, #7 Off
Blower Lo
Blower Med
Blower Hi
Aux Heat #1
Aux Heat #2
AuxHeat #3
Aux Heat #4
--
P5
11
4
9
2
10
5
13
6
7
14
1
12
3
8
12
6
15
10
7
4
5
14
9
2
1
3
11
16
R
8
P6
C
13
NOTE 4
68
T1GX, T2GX SERIES SPECIFICATION CATALOG
Wiring Schematics cont.
5-Speed ECM cont.
With optional EA Series 10kW Auxiliary Electric Heat shown
Place auxiliary heat schematic from kit here
Not Used
Black
Violet
Yellow
Blue
Gray
Brown
Not Used
Not Used
Orange
Blue
Pink
White
Tan
Red
Not Used
2
1
3
PB2
NOTE 1
Black
Tan Not Used
Orange
Orange
Not Used
Not Used
Pink
Pink
Yellow
Yellow
Blue
Blue
Black
Black
RV
T
T
Brown
Orange
P11
5
4
3
2
1
To PB2
Brown
Orange
Blue
Violet
Green
P9
1
2
3
5
4
Brown
Orange
208-230/60/1
L2
L1 G
TB
1 - Use copper or aluminum conductors.
2 – When Auxiliary Heat is installed the BLK/WHT wire from CC-L1 to PB2-2 and the GRY/WHT wire from CC-L2 to PB2-1 must be removed (located in the heat pump control box).
3 – Jumpers wires are Factory Installed, and are
Required for auxiliary heat operation.
4 – Low voltage wiring CLASS 2.
Black
Gray
Red
208V
Blue
240V
Transformer
24V
Yellow Black/White
P12
3
15
16
10
8
Green
1 2 3 4 5 P11
Connects to variable speed ECM motor only
Black
Gray
G
G
ER
3
N
O G
ER
4
C 1 2 3
P2
4
G
C
EA Series
PCB
1 2 3
N
O
P1
4
ER
1
ER
2
N
O
N
O
Gray
Black
HE1
HE2
Gray
Black
TS2
Gray
Black
Black
Gray
TS1
CO
P10 from unit’s control box connects to P2
P10
1
2
5
6
3
4
NOTE 3
Logic Board - Physical Layout
HWL
WCL
LP
HP
P4
1 2 3
F1 F1
N.O.
N.O.
N.C.
N.O.
N.O.
CR1- DHW
Pump
CC-GND
CC
CCLO
CCHI
C
C
R
R
SW1
Off On
3
4
1
2
10
11
12
8
9
6
7
1
P1
2 3 4 5
R C Y1 Y2 W
6 7
O G L
8
CR2- Loop
Pump
CR3-
Logic Board
Com Com
Microprocessor
SW2
Off On
1
Shut
Down
2
C
7
8
5
6
3
4
1
2
SW3
Off On
3
4
1
2
5
3
P2
C
4
SL1
IN
5
SL1
Out
6
SL2
IN
7
SL2
Out
CR4-
1
ACC
NO
9
10
11
12
13
14
15
16
2
3
4
5
6
7
8
8
9
10
11
12
13
14
1
2
3
4
5
6
P3
2
7
1
3
ACC
NC
ACC
COM
P6
P5
L1
Breaker
Factory Low voltage wiring
Factory Line voltage wiring
Field low voltage wiring
Field line voltage wiring
Optional block
DC Voltage PCB traces
Internal junction
Quick connect terminal
Wire nut
Field wire lug
Ground
Relay Contacts-
N.O., N.C.
Fuse
CC -
CO -
CR1 -
CR2-
CR3 -
CR4 -
CS -
F1 and F2 -
FP -
HE -
HP -
ER1 to ER4 -
Compressor Contactor
Condensate overflow sensor
DHW pump relay
Loop pump relay
PSC Fan Speed Relay
PSC Fan Power Relay
Compressor Solenoid
Fuses
Freeze protection sensor
Heater element
High pressure switch
Aux heat stage relays
Legend
12V
Zener Diode
T
G
Thermistor
Light emitting diode - Green
Relay coil
Capacitor w/ bleed resistor
Switch - Condensate overflow
Switch - High pressure
Switch - Low pressure
P
2 3 1
Switch -Hot Water On/Off
Polarized connector
LP -
PB1, PB2 -
PS -
RV -
SW1 -
SW2 -
SW3 -
SW4 -
TS -
HWL -
SC -
SR -
Low pressure switch
Power blocks
Power strip
Reversing Valve coil
DIP package 12 position
DIP package 8 position
DIP package 5 position
Hot water pump enable switch
Thermal limit switch
Hot water limit sensor
Start Contactor
Start Relay
69
T1GX, T2GX SERIES SPECIFICATION CATALOG
Wiring Schematics cont.
PSC
NOTE 2
C
SL1 In
SL1 Out
Optional
Remote Unit
Without
Loop Pump
NOTE 10
Optional
Electronic
Air-Filter
CC Violet(2)
Black(1)
Thermostat
R
C
Y1
Y2
W
O
G
L1
NOTE 9
SW4
R
R
G
Y
R
R
R
R
P2
Shut
Down
C
C
SL1 In
SL1 Out
Not
Used
4
5
6
7
NOTE 3
P3
Acc Com
Acc NC
Acc NO
1
2
3
P1
R
C
Y1
Y2
W
O
G
LO
CCHI
CC
CC-GND
3
4
5
1
2
6
7
8
Ext Pump
1/2 hp Total
208-230/60/1
Pump Pump
G
NO
Blue
2
PB1
2
1
1
Green
PSC
Blower
Motor
White
Brown
Cap
H M L
P13
Blue
NOTE 6
DHW
Pump
Pink
Yellow(8)
Gray(9)
Black
Compressor
S
NOTE 12
Green/Yellow
C
R
White
Unit Power
208-230/60/1
Run
Capacitor
G
Blue
Tan
(16)
L2
Red
CC
L1
Black
Black/White(11)
Gray/White(10)
NOTE 4
Orange(14) Brown(15)
Blue
Fused L2 Fused L2 240V L2
240V L2
F1-10A 240V
240V L1
NO NO NC NO NC
CR1
COM
CR2
COM
CR3 COM CR4 COM
2
1
3
PB2
NOTE 1
Black
Red
208V
Blue
240V
Transformer
24V
Yellow Black/White
Brown
Orange
Blk(7)
1 2 3
P4
Microprocessor
Logic Control
(DC Voltage)
ECM
Air Flow
Settings
SW1 On
7
8
5
6
3
4
1
2
9
10
11
12
SW2 On SW3 On
7
8
5
6
3
4
1
2
Test / Norm
Loop / Well
Fan / Comp
Dehum / Norm
No Htg3 / Htg3
Inputs / Norm
Outputs / Norm
Pulse L / Constant L (NOTE 9)
1 2 Speed / 1 Speed
2
3
Normal / Finish on 2
No RPM / RPM nd (Note 7)
4
5
Electric Heat / Normal (Note 8)
G Series / NA
Main Logic PCB
Diagnostic Modes
LED Normal Display Mode Current Fault Status Inputs Outputs Outputs2
Drain
Water Flow
High Press
Low Press / CA
Air Flow
Status
DHW Limit
DHW off
Field Selection Dips - #1 On, #6 On, #7 On
Drain pan overflow Lockout
WCL thermistor (loop<15°F,well<30°F) Lockout
High Pressure
Low Pressure / Comfort Alert
ECM2 RPM < 100 rpm Lockout
Microprocessor malfunction*
HWL thermistor > 130°F
DHW pump switch off
*Green LED not flashing
#1 Off, #6 On, #7 On
Drain pan overflow
WCL thermistor (loop<15°F,well<30°F)
High Pressure
#6 Off, #7 On
Y1
Y2
O
Low Pressure / Comfort Alert
ECM2 RPM < 100 rpm
Not Used
G
W
SL1
HWL thermistor > 130°F
DHW pump switch off
SL2
--
#6 On, #7 Off
Compressor Lo
Compressor Hi
RV
FAN
DHW Pump
Loop Pump 1
Loop Pump 2
--
#6 Off, #7 Off
Blower Lo
Blower Med
Blower Hi
Aux Heat #1
Aux Heat #2
AuxHeat #3
Aux Heat #4
--
13
6
7
14
3
8
1
12
5
P5
11
4
9
2
10
6
15
10
14
12
7
4
5
R
8
P6
C
13
11
16
9
2
1
3
Not Used
Black
Violet
Yellow
Blue
Gray
Brown
Not Used
Not Used
Orange
Blue
Pink
White
Tan
Red
Not Used
CO
P12
3
15
16
10
8
P10
1
2
5
6
3
4
Tan
Yellow
Yellow
Blue
Blue
Black
Black
Orange
Orange
Not Used
Not Used
Pink
Pink
Not Used
RV
T
T
HWL
WCL
LP
HP
Notes:
1 – Switch Blue and Red wires for 208V operation.
2 - Connection of remote unit that does not have a loop pump for slave operation.
3 - 24V Accessory relay (see SW2 - 3 for description of operation)
4 - The blk/wh and gray/wh wires are removed when Aux Heat is installed.
5 – Use manufacturer part number 19P592-01 (jumper bar assembly)
when single source power is required.
6 - DHW pump only in models with hot water generation option.
7 – This Switch allows the unit to down stage with the t-stat when OFF and finish on second stage when
ON.
8 – SW3-4 should be in the OFF position when using the 17P501A01 electric heat board and
should be ON when using the 17P514A01 electric heat board .
9 – SW2-8 must be in the OFF position for pulsed “L” lockout signal and in the ON position for constant
“L” lockout signal.
10 - When optional electronic air-filter is installed, power for the electronic air-filter is provided by P2-2 and
24 VAC.
11 – Low voltage wiring CLASS 2.
12 – Ground wire only on units with aluminum air coils.
P11
5
4
3
2
1
70
T1GX, T2GX SERIES SPECIFICATION CATALOG
Wiring Schematics cont.
PSC cont.
To PB2
Green
1 2 3 4 5 P11
Connects to variable speed ECM motor only
With optional EA Series 10kW Auxiliary Electric Heat shown
Place auxiliary heat schematic from kit here
Brown
Orange
Blue
Violet
Green
3
5
4
P9
1
2
Brown
Orange
208-230/60/1
L2 L1 G
1 - Use copper or aluminum conductors.
2 – When Auxiliary Heat is installed the BLK/WHT wire from CC-L1 to PB2-2 and the GRY/WHT wire from CC-L2 to PB2-1 must be removed (located in the heat pump control box).
3 – Jumpers wires are Factory Installed, and are
Required for auxiliary heat operation.
4 – Low voltage wiring CLASS 2.
Black
Gray
TB
Black
Gray
G
G
ER
3
N
O
G
C 1
ER
4
2 3
P2
4
G
C
EA Series
PCB
1 2 3
N
O
P1
4
ER
1
ER
2
N
O
N
O
Gray
Black
P10 from unit’s control box connects to P2
NOTE 3
HE1
Gray
TS1
HE2
Gray
Black
TS2
Gray
Black
Black
CSA installed units only
Local codes may require a single source of power supply
Single Disconnect Power
208-230/60/1
Breaker box
L1 L2 furnished by installer
L1
Circuit Breakers
L2 L1 L2
Aux Elect Power
208-230/60/1
Unit Power
208-230/60/1
Legend
L1
Breaker
Factory Low voltage wiring
Factory Line voltage wiring
Field low voltage wiring
Field line voltage wiring
Optional block
DC Voltage PCB traces
Internal junction
Quick connect terminal
Wire nut
Field wire lug
Ground
Relay Contacts-
N.O., N.C.
Fuse
T
G
Thermistor
Light emitting diode - Green
Relay coil
Capacitor w/ bleed resistor
Switch - Condensate overflow
Switch - High pressure
Switch - Low pressure
P
2 3 1
Switch -Hot Water On/Off
Polarized connector
CC -
CO -
CR1 -
CR2-
CR3 -
CR4 -
CS -
F1 and F2 -
FP -
HE -
HP -
ER1 to ER4 -
Compressor Contactor
Condensate overflow sensor
DHW pump relay
Loop pump relay
PSC Fan Speed Relay
PSC Fan Power Relay
Compressor Solenoid
Fuses
Freeze protection sensor
Heater element
High pressure switch
Aux heat stage relays
LP -
PB1, PB2 -
PS -
RV -
SW1 -
SW2 -
SW3 -
SW4 -
TS -
HWL -
SC -
SR -
Low pressure switch
Power blocks
Power strip
Reversing Valve coil
DIP package 12 position
DIP package 8 position
DIP package 5 position
Hot water pump enable switch
Thermal limit switch
Hot water limit sensor
Start Contactor
Start Relay
Logic Board - Physical Layout
P4
1 2 3
F1 F1
N.O.
N.O.
N.C.
N.O.
N.O.
CR1- DHW
Pump
CC-GND
CC
CCLO
CCHI
C
C
R
R
SW1
Off On
7
8
5
6
3
4
1
2
9
10
11
12
1 2 3
R C Y1 Y2
P1
4 5
W
6
O
7
G L
8
CR2- Loop
Pump
CR3-
Logic Board
Com Com
Microprocessor
SW2
Off On
1
Shut
Down
2
C
7
8
5
6
3
4
1
2
SW3
Off On
3
4
1
2
5
3
P2
C
4
SL1
IN
5
SL1
Out
6
SL2
IN
7
SL2
Out
CR4-
1
ACC
NO
9
10
11
12
13
14
15
2
3
4
5
6
7
16
8
8
9
1
2
10
11
12
13
14
2
P3
3
4
5
6
7
1
ACC
NC
3
ACC
COM
P6
P5
71
T1GX, T2GX SERIES SPECIFICATION CATALOG
Engineering Guide Specifi cations
General
Furnish and install Water Source Heat Pumps, as indicated on the plans. Equipment shall be completely assembled, piped and internally wired. Capacities and characteristics as listed in the schedule and the specifications that follow. The reverse cycle heating/cooling units shall be either suspended type with horizontal air inlet and discharge or floor mounted type with horizontal air inlet and vertical upflow, downflow, or rear air discharge. Units shall be AHRI/ISO 13256-1 certified and listed by a nationally recognized safety-testing laboratory or agency, such as ETL
Testing Laboratory. Each unit shall be computer run-tested at the factory with conditioned water and operation verified to catalog data. Each unit shall be mounted on a pallet and shipped in a corrugated box or stretch-wrapped. The units shall be designed to operate with entering liquid temperature between 20°F and 120°F
[-6.7°C and 48.9°C].
Casing and Cabinet
The cabinet shall be fabricated from heavy-gauge galvanized steel and finished with corrosion-resistant powder coating. This corrosion protection system shall meet the stringent 1000 hour salt spray test per ASTM B117. The interior shall be insulated with
1/2-inch thick, multi-density, cleanable aluminum foil coated glass fiber with edges sealed or tucked under flanges to prevent the introduction of glass fibers into the discharge air. Standard cabinet panel insulation must meet NFPA 90A requirements, air erosion and mold growth limits of UL-181, stringent fungal resistance test per ASTM-C1071 and ASTM G21, and shall meet zero level bacteria growth per ASTM G22. Unit insulation must meet these stringent requirements or unit(s) will not be accepted.
One (horizontal) to two (vertical) blower and three compressor compartment access panels shall be ‘lift-out’ removable with supply and return ductwork in place. The front access panel shall be lift-out to provide easy access to the electrical/compressor section. The internal component layout shall provide for service access from the front side for restricted installations.
A duct collar shall be provided on the supply air opening. Standard size 2 in. [5.1 cm] MERV 11 pleated filters shall be provided with each unit. Vertical units shall have a return air filter rack/duct collar; the horizontal units shall have a filter bracket each field convertible from 2 in. [5.1 cm] to 1 in. [2.5 cm]. The upflow vertical (022-072) units shall have a removable insulated divider panel between the air handling section and the compressor section to minimize the transmission of compressor noise and to permit operational service testing without air bypass. Vertical units shall be supplied with left or right horizontal air inlet and top, bottom (022-072), or rear vertical (042-072) air discharge. Horizontal units shall be supplied with left or right air inlet and side or end air discharge.
The compressor shall be double isolation mounted using selected durometer grommets to provide vibration free compressor mounting.
The drain pan shall be of plastic construction to inhibit corrosion and bacterial growth. Drain outlet shall be located on pan as to allow complete and unobstructed drainage of condensate.
The unit as standard will be supplied with solid-state electronic condensate overflow protection. Mechanical float switches WILL
NOT be accepted. Vertical units shall be furnished with a PVC slip condensate drain connection and an internal factory installed condensate trap.
Refrigerant Circuit
All units shall contain a sealed refrigerant circuit including a hermetic motor-compressor, discharge line muffler (022-072), bidirectional thermostatic expansion valve, finned tube air-torefrigerant heat exchanger, reversing valve, coaxial tube waterto-refrigerant heat exchanger, optional hot water generator coil
(018-072), and service ports.
Compressors shall be high-efficiency single speed rotary or scroll, or dual capacity scroll type designed for heat pump duty and mounted on vibration isolators. Compressor motors shall be single-phase PSC with overload protection. The finned tube air-to-refrigerant heat exchanger will be aluminum tube/fin shall be sized for low-face velocityand constructed of lanced aluminum fins bonded to performanceenhanced tubes in a staggered pattern not less than three rowsdeep for superior performance.
The aluminum tube and fin air-to refrigerant heat exchanger has as optional to be electro-coated with AlumiSeal. Models 022-072 shall include discharge mufflers to help quiet compressordischarge gas pulsations. Refrigerant to air heat exchangers shallutilize enhanced tube construction rated to withstand 600 psig (4135kPa) refrigerant working pressure.
The coaxial water-to-refrigerant heat exchanger shall be designed for low water pressure drop and constructed of a convoluted copper
(cupronickel option) inner tube and a steel outer tube. Refrigerant to water heat exchangers shall be of copper inner water tube and steel refrigerant outer tube design, rated to withstand 600 psig (4135 kPa) working refrigerant pressure and 450 psig (3101 kPa) working water pressure. The thermostatic expansion valve shall provide proper superheat over the entire liquid temperature range with minimal
“hunting.” The valve shall operate bidirectionally without the use of check valves.
All units shall have the source coaxial tube refrigerant-to-water heat exchanger and the optional hot water generator coil shall be coated with ThermaShield. Refrigerant suction lines shall be insulated to prevent condensation at low liquid temperatures.
72
T1GX, T2GX SERIES SPECIFICATION CATALOG
Engineering Guide Specifi cations cont.
Blower Motor and Assembly
The blower shall be a direct drive centrifugal type with a dynamically balanced wheel. The housing and wheel shall be designed for quiet low outlet velocity operation. The blower housing shall be removable from the unit without disconnecting the supply air ductwork for servicing of the blower motor. The blower motor shall be a 3-speed PSC, 5-speed ECM, or variable speed ECM type. The variable speed ECM blower motor shall be soft starting, shall maintain constant cfm over its operating static range and shall provide 12 cfm settings. An optional constant torque 5-speed ECM is available on model sizes 022-072. An optional 3-speed PSC blower motor is available on all single speed models. The blower motor shall be isolated from the housing by rubber grommets. The motor shall be permanently lubricated and have thermostatic overload protection. Variable speed ECM and
5-speed ECM motors shall be long-life ball bearing type
.
Piping
Supply and return water connections shall be 1 in. [25.4 mm] FPT brass swivel fittings, which provide a union and eliminate the need for pipe wrenches and sealants when making field connections. The optional hot water generator shall have sweat type connections. All water piping shall be insulated to prevent condensation at low liquid temperatures, on the vertical units, the condensate connection shall be a 3/4 in. [19.1 mm] PVC socket with internally-trapped hose that can be routed to front or side locations.
Hanger Kit
(field-installed horizontal units only)
The hanger kit shall consist of galvanized steel brackets, bolts, lock washers, and isolators and shall be designed to fasten to the unit bottom panel for suspension from 3/8-inch threaded rods. Unit sizes 012-030 shall include four brackets. Unit sizes 036-072 shall include six brackets.
Electrical
A control box shall be located within the unit compressor compartment and shall contain a 75VA transformer, 24 volt activated,
2 pole compressor contactor, circuit breakers for protecting loop pumps, terminal block for thermostat wiring, and solid-state controller for complete unit operation. Electromechanical operation WILL NOT be accepted. Units shall be name-plated for use with time delay fuses or HACR circuit breakers. Unit controls shall be 24 volt and provide heating or cooling as required by the remote thermostat/sensor. An
Aurora, a microprocessor-based controller, interfaces with a multistage electronic thermostat to monitor and control unit operation shall be provided. The control shall provide operational sequencing, blower speed control, blower failure, high and low pressure switch monitoring, freeze detection, hot water limit thermistor sensing, condensate overflow sensing, auxiliary heat staging, lockout mode control, hot water and loop pump control, LED status and fault indicators, fault memory, field selectable options, and accessory output. The Lockout signal output shall have a pulsed option so that
DDC systems can read specific lockout conditions from the control.
Options and Accessories
Cupronickel Heat Exchanger
An optional cupronickel water-to-refrigerant heat exchanger shall be provided.
Hot Water Generator
An optional ThermaShield coated heat reclaiming hot water generator coil of vented double-wall copper construction suitable for potable water shall be provided. The coil and hot water circulating pump shall be factory mounted inside the unit with integral electronic high limit temperature monitoring and external on/off switch.
5-Speed ECM Blower Motor
An optional 5-speed ECM blower motor is available on model sizes
022-072.
A detachable terminal block with screw terminals will be provided for field control wiring. All units shall have knockouts for entrance of low and line voltage wiring. The blower motor and control box shall be harness plug wired for easy removal.
Optional IntelliStart ® (compressor Soft Starter) shall be factory installed for use in applications that require low starting amps, reduced compressor start-up noise, off-grid, and improved start-up behavior. IntelliStart shall reduce normal starting current by 60% on 208/60/1 units.
PSC Blower Motor
An optional 3-speed PSC blower motor is available on all single speed models.
Thermostat (field-installed)
A multi-stage auto-changeover electronic digital thermostat shall be provided. The thermostat shall offer three heating and two cooling stages with precise temperature control. An OFF-HEAT-
AUTO-COOL-EMERG system switch, OFF-AUTO blower switch, and indicating LEDs shall be provided. The thermostat shall display in °F or °C. The thermostat shall be either a communicating type or a traditional 24 VAC type.
73
T1GX, T2GX SERIES SPECIFICATION CATALOG
Engineering Guide Specifi cations cont.
AlpinePure Drain Pan Treatment (field installed)
Provides dependable, sustained time-release protection from slime build-up and foul smelling odors in the drain pan. Also adds a light, pleasant scent to the air.
Earth Loop Flow Center (field-installed)
A self-contained module shall provide all liquid flow, fill and connection requirements for ground source closed loop systems up to 20 gpm. The pumps shall be wired to a power block located in the nearest unit. The heat pump units shall contain low voltage pump linking control so that two units may share one flow center.
Auxiliary Heater (field-installed)
An electric resistance heater shall provide supplemental and/or emergency heating capability. Vertical units shall have the control panel and resistance heater coil assembly mounted internally. For horizontal units, the control panel shall be mounted internally while the resistance heater coil assembly shall be mounted externally. A low voltage plug shall be provided in each unit for quick auxiliary heat connection. The heater shall operate in sequenced stages as controlled by the unit’s microprocessor. The heater shall feed line voltage power to the unit blower and transformer to provide emergency heat capability in the event of an open compressor circuit breaker.
74
Revision Guide
Pages: Description:
All
Edits
Edits
Misc.
First Published.
Edits per JA
Edits per MA
Nomenclature, Schematics change
T1GX, T2GX SERIES SPECIFICATION CATALOG
Date:
11 Jun 2013
28 Jun 2013
28 Sep 2015
1 Dec 2016
By:
DS
LP
LP
JM
75
Product:
Type:
Size:
T1GX, T2GX Series
Geothermal/Water Source Heat Pump
1-6 Ton Single Speed
2-6 Capacity
Document Type: Specifi cation Catalog
Part Number:
Release Date:
022-1853-6
1/17
©2017 The manufacturer has a policy of continual product research and development and reserves the right to change design and specifi cations without notice.
Advertisement