Veilux D136X-I/O User manual
Advertisement
Advertisement
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O,
D136X-I/O, D136X With WDR-I/O, D137X-I/O
I= Indoor D= Outdoor
Website: www.Veilux.net Phone# 1-800-510-6528
Rev.1.0 (April 2011)
1
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O,
D136X-I/O, D136X With WDR-I/O, D137X-I/O
I= Indoor D= Outdoor
Certification
Veilux provides the best products with the certification below.
Revision History
Date Rev No.
2010-11 1.0
Description
Creation of the document
Website: www.Veilux.net Phone# 1-800-510-6528
Rev.1.0 (April 2011)
2
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O,
D136X-I/O, D136X With WDR-I/O, D137X-I/O
I= Indoor D= Outdoor
Warning & Cautions
If you fail to read this information and handle the product incorrectly, faulty or malfunction as well as
death or serious injury may occur.
This Unit should be installed by trained personnel.
Immediately stop using when the product emits smoke or abnormal heat.
Never install the product in area exposed to oil or gas.
Never install the product on a ceiling that cannot hold its weight.
Never touch the power cord with wet hands.
Clean only with dry cloth.
Never use the product in extremely high or low temperature condition.
Never drop, hit, strongly nor vibrate the product.
Never expose the product to direct sunlight or severe ray.
Never touch the front glass of the product.
Website: www.Veilux.net Phone# 1-800-510-6528
Rev.1.0 (April 2011)
3
Indications:
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O,
D136X-I/O, D136X With WDR-I/O, D137X-I/O
I= Indoor D= Outdoor
Warning: Death or Serious Injury will occur without following Warning.
Caution : Operational Problem(Faulty & Malfunction) will occur without complying with Caution
Reference : Technical Information for Users
Website: www.Veilux.net Phone# 1-800-510-6528
Rev.1.0 (April 2011)
4
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O,
D136X-I/O, D136X With WDR-I/O, D137X-I/O
I= Indoor D= Outdoor
Table of Contents
Table of Contents ................................................................................ 5
Introduction ................................................................................... 7
1.1. Overview of Veilux VPIP-D1XXX-O / VPIP-D1XXX-I .......................................... 7
1.2.2. Detailed Specification of Camera Module & PTZ of Veilux VPIP-D1XXX-O / VPIP-D1XXX-I...... 9
1.2.4. Detailed Specification of Camera Module of Veilux VPIP-D1XXX-O / VPIP-D1XXX-I ............ 12
1.3. Application of Veilux VPIP-D1XXX-O / VPIP-D1XXX-I ...................................... 14
Production Description................................................................... 15
Bracket Installation ...................................................................... 22
Website: www.Veilux.net Phone# 1-800-510-6528
Rev.1.0 (April 2011)
5
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O,
D136X-I/O, D136X With WDR-I/O, D137X-I/O
I= Indoor D= Outdoor
Installation .................................................................................. 31
Trouble Shooting .......................................................................... 36
5.2. Windows vista and Windows 7 User for Record & Capture Problem ................... 37
Appendix .................................................................................... 41
Website: www.Veilux.net Phone# 1-800-510-6528
Rev.1.0 (April 2011)
6
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O,
D136X-I/O, D136X With WDR-I/O, D137X-I/O
I= Indoor D= Outdoor
1. Introduction
1 .
1 .
O v e r r v i i e w o f V e i i l l u x V P I I P D 1 X X X O / / V P I P D 1 X X X I I
Veilux VPIP-D1XXX-O / VPIP-D1XXX-I, as a state-of-the-art 1Channel Speed Dome Network Camera based on integrated Embedded Software technologies such as H.264 & MJPEG, G.726 & PCM Video & Audio
Compression, Embedded Web Server, Embedded Streaming Server, various Network Protocols, transmits synchronized video and audio data in real time through IP Network as well as supports bi-directional audio communication by allowing transmission of audio from Client PC Veilux VPIP-D1XXX-O / VPIP-D1XXX-I.
Veilux VPIP-D1XXX-O / VPIP-D1XXX-I with completed Integration with analog CCTV camera, Digital and network technology, is applicable for various sectors such as Security, Remote Monitoring, Remote Education,
Simple Video Conference as well as Internet Broadcasting System etc.
Website: www.Veilux.net Phone# 1-800-510-6528
Rev.1.0 (April 2011)
7
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O,
D136X-I/O, D136X With WDR-I/O, D137X-I/O
I= Indoor D= Outdoor
1
.
.
2 .
.
S p e c i i f i i c a t i i o n
1 .
2 .
1 .
.
B a s i c S p e c i i f i i c a t t i i o n o f f V e i l l u x V P I P D 1 X X X O / / V P I I P D 1 X X X I
Time
Configuration
Management
Class Description
Video
Audio
(Bi-directional)
Compression
Resolution
Up Stream
Down Stream
Security Management
H.264 / MJPEG
**Refer to the datasheet
32 Kbps G.726
64 Kbps PCM
Interface RJ-45, 10/100 Mbps
Network
Access Network Static, DHCP, PPP/PPPoE
Protocol IPv4/6, TCP, UDP, IGMP, ICMP, ICMPv6 etc.
Sensor
Relay Output
4
2
NC, NO Selectable
Alarm or Remote ON/OFF Control (30V, 1A)
I/O
Power
RS-232C
Mic/Line In
Line Out
CVBS Output
PoE
AC In
Housing
Water-Proof
Heater
Installation Type
Motion Detection
Upgrade
Bracket
3 Regions
Factory Default
Selectable on Admin Page
1 V p-p Audio Output for Amp embedded Speaker
Supported
24VAC Adaptor (higher than 1.5 Amp)
IP66
Refer to Installation Configuration
Wall, Ceiling, Ceiling Embedded Type
Optional Shape & Sensitivity for 3 Regions
Remote F/W Upgrade via IP Network
Management & Configuration
Client/Viewer
Dynamic IP
Web Viewer
NVR-Pro
Remote Management & Configuration using IP Network and
Admin Tool Page
Simple Access via Internet explorer
CMS Software
3rd Party CMS Contact to Veilux
DDNS support Supported by Veilux Management Server
User ID & Password Protection, IP Filtering, Audio per user and Bi-directional audio communication configuration control
Sync to PC
Manual
Sync to PC Time
Manual Configuration
Internet Time Server
Sync to Time Server
Website: www.Veilux.net Phone# 1-800-510-6528
Rev.1.0 (April 2011)
8
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O,
D136X-I/O, D136X With WDR-I/O, D137X-I/O
I= Indoor D= Outdoor
DLS Time Configuration
1 .
.
2 .
.
2
.
.
D e t a i i l l e d S p e c i i f i i c a t t i i o n o f f C a m e r r a M o d u l l e & P T Z o f V e i i l l u x V P
I
I P
-
-
D
1 X X X
-
O
/
/ V P I
I
P
-
D 1 X
X
X -
I
I
Class
18X Optical 26X Optical
27X Optical 33X Optical
36X Optical
(WDR)
37X Optical
PAN Rotation Angle
PAN Manual
360˚
0.5˚ ~ 200˚/sec (64step)
PAN
/
TILT
Rotation
Speed
Preset
TILT Rotation Angle
Max.
300˚ /sec , Min. 10˚ /sec
TILT Speed
Manual
Preset
System Accuracy
-
2˚ ~ 90˚
0.5˚ ~ 45˚/sec (64step)
Max.
250˚ /sec , Min. 200˚ /sec
0.024˚
Preset 165 Presets identifiable with 16 character label for each preset.
Camera
Module
Group Tour
Functions
Mis.
Auto Rotation
Pattern
Sector
Password Protection
Privacy Zone
Alarm Input
Alarm Actions
AUX Output
Auto Flip
OSD Menu
Serial
Communication
Protocol
Motor
Micro Step
Image Sensor
24
1/4" Sony
Exview
HAD CCD
Max. 8 Programmable Group Tours
(Max. 60 different Presets Steps for each Group Tour)
Programmable Auto Scan
Max. 8 Programmable Patterns( 50sec/Pattern, Total 480sec)
16 character label identifiable 8 Programmable Sectors
Yes
24 8 8
Max. 4 Alarm Input (Programmable)
24
Preset, Group Scan or Activate Output on Alarm Input
2 Relay Output
ON / OFF
Yes
RS-485
1/4"Sony
Exview
HAD CCD
Pelco-D, Pelco-P Embedded
Stepping Motor
1/8 Micro Step
1/4"Sony super
HAD CCD
1/4"Sony super
HAD CCD
1/4"Sony
Exview
HAD CCD
8
1/4"Sony super
HAD CCD
No. of NTSC 811(H) * 508(V) 410K
Website: www.Veilux.net Phone# 1-800-510-6528
Rev.1.0 (April 2011)
9
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O,
D136X-I/O, D136X With WDR-I/O, D137X-I/O
I= Indoor D= Outdoor
Pixels
No. of
Effective
Pixels
PAL
NTSC
PAL
795(H) * 596(V) 470K
768(H) * 494(V) 380K
752(H) * 582(V) 440K
Horizontal
Resolutio n
ZOOM
NTSC 470TV line 470TV line
PAL 460TV line 460TV line
550TV line(Color)
680TV line(B/W)
550TV line(Color)
680TV line(B/W)
530TV line(Color)
530TV line(Color)
550TV line(Color)
680TV line(B/W)
Optical
18x Optical
Zoom
(F=1.4~3.0,
)
26x Optical
Zoom
(F=1.6~3.8,
)
27x Optical
Zoom
(F=1.6~2.9,
)
33x Optical
Zoom
(F=1.6~3.6, f=4.1~73.8mm
f=3.5~91.0mm
f=3.5~94.5mm
f=3.5~115.5m
m)
36x Optical
37x Optical
Zoom
Zoom
(F=1.6~4.5, f=3.4~122.4m
f=3.5~129.5mm) m )
(F=1.6~3.9,
Digital 12x (total 216x) 12x (total 312x) 12x (total 324x) 12x (total 396x) 12x (total 432x) 12x (총 444x)
Day/Night(ICR)
Digital Slow Shutter
Normal
(50IRE)
Min.
Illuminatio
(ICR ON) n
B/W
Sense-up :
256x
Luminance S/N
Ratio
Video Output
BLC
Flicker less
0.05Lux
0.01Lux
N/A
0.14Lux
0.05Lux
N/A
Auto/ Day/ Night
ON/ OFF
0.4Lux
0.02Lux
0.00007Lux
0.4Lux
0.02Lux
0.00007Lux
Higher than 50dB
Video Output 75
ON / OFF
ON / OFF
Ω
0.1Lux
0.01Lux
N/A
0.7Lux
0.061Lux
0.00007Lux
Website: www.Veilux.net Phone# 1-800-510-6528
Rev.1.0 (April 2011)
10
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O,
D136X-I/O, D136X With WDR-I/O, D137X-I/O
I= Indoor D= Outdoor
1 .
2 .
3 .
.
B a s i c S p e c i i f i i c a t t i i o n o f f V e i l l u x V P I P D 1 X X X O / / V P I I P D 1 X X X I
Class Description
Video
Audio
Network
I/O
Power
Housing
Compression
Resolution
H.264 / MJPEG
1280x720, 800x608, 704x480, 640x480, 704x240,
352x240,176x112
Up Stream
Down Stream
32 Kbps G.726
64 Kbps PCM
Interface RJ-45, 10/100 Mbps
Access Network Static, DHCP, PPP/PPPoE
Protocol
Sensor(Alarm)
IPv4/6, TCP, UDP, IGMP, ICMP, ICMPv6 etc.
4 NC, NO Selectable
Relay Output(Aux)
Mic/Line In
Line Out
CVBS Output
PoE
AC In
Water-Proof
Fan & heater
2 Alarm or Remote ON/OFF Control (30V, 1A)
Selectable on Admin Page
1 V p-p Audio Output for Amp embedded Speaker
Supported
Not Supported
24V AC Adaptor (higher than 1.5 Amp)
IP66
Supported
Installation
Type
Motion
Detection
Upgrade
Bracket
3 Regions
Wall, Ceiling, Embedded(Flush)
Optional Shape & Sensitivity for 3 Regions
Management & Configuration
Client/Viewer
Dynamic IP
Time
Configuration
Web Viewer
NVR-Pro
3rd Party CMS
DDNS support
Security Management
Sync to PC
Manual
Remote F/W Upgrade via IP Network
Remote Management & Configuration using IP Network and Admin
Tool Page
Simple Access via Internet explorer
CMS Software
Contact to iCanTek
Supported by iCanTek
’s Management Server
User ID & Password Protection, IP Filtering, Audio per user and Bidirectional audio communication configuration control
Sync to PC Time
Manual Configuration
Website: www.Veilux.net Phone# 1-800-510-6528
Rev.1.0 (April 2011)
11
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O,
D136X-I/O, D136X With WDR-I/O, D137X-I/O
I= Indoor D= Outdoor
Management
Internet Time Server
Sync to Time Server
DLS Summer Time Configuration
1 .
2 .
4 .
.
D e t a i l l e d S p e c i i f i i c a t t i i o n o f f C a m e r r a M o d u l l e o f V e i i l l u x V P I I P D 1 X X X O / / V P I I P D 1 X X X I I
Class Description
CCD Image
Sensor
Lens
Focus
IR Removable
Image Size
Effective Pixels
Progressive Scan
Output Pixels / FPS
Optical Zoom
Practical f-value
Practical H.angle
F-value
Auto
Manual (Far/Near)
Focal Range (setting)
Auto
Manual (On/Off)
Durability
DSP Function
Zoom / Focus / Iris
IR Removable
Digital Slow Shutter
Wide Dynamic Range
Image Freeze
Mirror
Vertical Invert
Image Reverse
Privacy Masking
Motion Detect
Frame Noise Reduction
Preset
Dynamic Spot Cancel
Shutter Speed
Electrical Shutter
Iris
Sensitivity
BLC
White Balance
6mm Dia. (Type 1/3)
1.3M (1296 x 966)
YES
1280(H)x720(V) / 30fps
18X
4.7~84.6mm
55.2°(w)~3.2°(t)
F1.6(w)~F2.8(t)
VAF
Provided (soft)
Infinity~1m(t)~0.01m(w) (soft)
Pro.AER+
Provided (soft)
500k cycles
50k cycles
YES
Off / On (soft)
Off / On (soft)
Off / On (soft)
Off / On (soft)
Off / On (soft)
8 zone
Off / On (soft)
Off / On (soft)
Max. 135
YES
Auto (1/30s~1/4000s)
Max. 1/4s (soft)
Off / On (soft)
Off / On (soft)
Website: www.Veilux.net Phone# 1-800-510-6528
Rev.1.0 (April 2011)
12
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O,
D136X-I/O, D136X With WDR-I/O, D137X-I/O
I= Indoor D= Outdoor
Resolution Horizontal
Min. Sensitivity
(F1.6, 50IRE)
IR-cut On (1/30s)
IR-cut Off (1/4s)
600 TVL (1280 x 720 pixels)
1.8 Lux
0.02 Lux
Website: www.Veilux.net Phone# 1-800-510-6528
Rev.1.0 (April 2011)
13
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O,
D136X-I/O, D136X With WDR-I/O, D137X-I/O
I= Indoor D= Outdoor
1 .
.
3 .
.
A p p l l i i c a t t i i o n o f f V e i i l l u x V P I
I
P
-
D 1 X X X
-
O /
/
V P I
I
P
-
-
D
1 X X
X -
I
I
- Security Surveillance (Building, Stores, Manufacturing Device, Parking Lot, Bank, Public Office &
Military etc.)
- Remote Monitoring (Hospital, Kindergarten, Traffic Status, Public Area)
- Video Conference, Remote Lecture, Internet Broadcasting
- Climate & Environment Surveillance
Website: www.Veilux.net Phone# 1-800-510-6528
Rev.1.0 (April 2011)
14
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O,
D136X-I/O, D136X With WDR-I/O, D137X-I/O
I= Indoor D= Outdoor
2. Production Description
2 .
1 .
P a c k a g e C o n t e n t s
Open the package and check if the followings are included;
2 .
.
1 .
.
1
.
.
V e i i l l u x V P I
I P
Contents Description Remark
Bracket & Housing Outdoor Housing, Wall Mount Bracket
Accessories
Manual
Screw (M4x15 4EA), Safety Cable
Housing Installation Manual
IP Camera
Tools & Accessories
CD
Veilux VPIP-D Body
Wrench, Safety Cable, Cable Tie, Terminal
Block
(2Pin, 3Pin , 5Pin ,6Pin : 1EA), Screw(Ø 3x6
2EA, Ø4x16 5EA)
Software & Product User Manual
Quick Reference
2 .
.
1 .
.
2
.
.
V e i i l l u x V P I
I
P
I
I
Content
IP Camera
Tools & Accessories
Quick Installation Guide
Description
Veilux VPIPI-D Body
Wrench, Safety Cable, Cable Tie, Terminal
Block
(2Pin, 3Pin , 5Pin ,6Pin : 1EA), Screw(Ø 3x6
2EA, Ø4x16 5EA)
Software & Product User Manual CD
Quick Reference Quick Installation Guide
* 24V AC Adaptor, as optional item, can be purchased separately.
Remark
Website: www.Veilux.net Phone# 1-800-510-6528
Rev.1.0 (April 2011)
15
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O,
D136X-I/O, D136X With WDR-I/O, D137X-I/O
I= Indoor D= Outdoor
2 .
.
2 .
.
P r e v i i e w
Veilux VPIP-D1XXX-O / VPIP-
D1XXX-I
IP-Installer
CMS Software
(NVXR-64)
Speed Dome Network Camera IP Assignment Program
PC based Client for monitoring/storing Video/Audio transmitted form Product
(Max. 16CH supported)
Website: www.Veilux.net Phone# 1-800-510-6528
Rev.1.0 (April 2011)
16
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O,
D136X-I/O, D136X With WDR-I/O, D137X-I/O
I= Indoor D= Outdoor
2 .
.
3 .
.
P h y s i i c a l l
D e s c r i i p t t i i o n
2 .
3 .
1 .
.
E x t e r r n a l l V i i e w
Fig 2-1. External View of Veilux VPIP-D1XXX-O / VPIP-D1XXX-I
2 .
3 .
2 .
.
B o t t t o m V i e w & C o n n e c t i i o n D i a g r r a m
Fig 2-2. Terminal Block, LAN & AC Power Connector
Website: www.Veilux.net Phone# 1-800-510-6528
Rev.1.0 (April 2011)
17
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O,
D136X-I/O, D136X With WDR-I/O, D137X-I/O
I= Indoor D= Outdoor
2 .
3 .
3 .
.
E x t e r r n a l l & I n t t e r r n a l V i e w
Fig 2-3. Connector Part
Fig 2-4. Outdoor Housing
Website: www.Veilux.net Phone# 1-800-510-6528
Rev.1.0 (April 2011)
18
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O,
D136X-I/O, D136X With WDR-I/O, D137X-I/O
I= Indoor D= Outdoor
2 .
.
4 .
.
F u n c t t i i o n a l l
D e s c r r i i p t t i i o n
AC Power
Connect 24 Volt AC adaptors to this terminal for supplying power to the network camera.
AC adapter which is compliant to the specification for Veilux VPIP-D1XXX-O / VPIP-D1XXX-I should be used. Misuse of power supply can cause damage to Veilux VPIP-D1XXX-O / VPIP-
D1XXX-I. Veilux assumes no responsibility for misuse of the power supply.
MIC/LINE IN
Connect external audio source or microphone.
Line Out
Connect speakers with built in amplifier. Audio from remote site is output through Line out in bi-directional audio mode.
100Base-T
100Mbps Ethernet connector (RJ-45). 2 LEDs on the Ethernet connector shows the status of Veilux VPIP-
D1XXX-O / VPIP-D1XXX-I as the followings:
- Status LED (Dual Color - Red/Green): It will be lit in green or red depending on the status.
Green: Green color indicates that the camera is in normal operation mode. Continuous green
Indicates that data transmission is possible. Blinking green means that someone is
Connected to Veilux VPIP-D1XXX-O / VPIP-D1XXX-I.
Red: Continuous or blinking red indicates that hardware is in abnormal condition.
Red/Green LED will be lit with red momentarily and it will be lit with green after a while when power is applied into Veilux VPIP-D1XXX-O / VPIP-D1XXX-I.
LINK/LAN LED (Orange) : It will be lit with orange color when network cabling is all right. Blinking orange color indicates that normal data transmission is under way. Off state indicates that there is trouble in network connection.
Website: www.Veilux.net Phone# 1-800-510-6528
Rev.1.0 (April 2011)
19
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O,
D136X-I/O, D136X With WDR-I/O, D137X-I/O
I= Indoor D= Outdoor
-
Alarm In/Out (ALARM/AUX)
Used for connecting alarm sensor, alarm annunciation device to Veilux VPIP-D1XXX-O / VPIP-D1XXX-I.
Class Description
Alarm IN
Alarm IN GND
Aux OUT
Aux OUT(GND)
Sensor In (+). NC/NO Selectable in Admin Mode
Ground for Sensor In
Alarm Output Terminal
Ground for Sensor Output
Aux
Relay output is provided for connecting alarm devices or for remote on/off control of devices such as light.
Relay is normal open and it will be closed upon alarm annunciation or remote on. The relay is capable of switching 30V AC/DC, 2A . For the application which needs power switching beyond this limit, use additional relay switch as shown as below figure.
Fig 2-5. Relay Connection Diagram(Left : lower than 30V, 2A, Right : Higher than 30V 2A)
Alarm
Connect external alarm sensor. Examples of sensing devices are infrared sensor, motion sensor, heat/smoke sensor, magnetic sensor, etc.
Connect the two wires of the sensors to “SNS In”. The sensor type (NC/NO) can be set in admin page. 10mA can be flown into sensor device. Multiple sensor devices can be connected in parallel.
Website: www.Veilux.net Phone# 1-800-510-6528
Rev.1.0 (April 2011)
20
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O,
D136X-I/O, D136X With WDR-I/O, D137X-I/O
I= Indoor D= Outdoor
Photo Coupler
Sensor1+
NO/NCType
Sensor
Device
+12V
Sensor1-
GND
Sensor
Power
Supply
Fig 2-6. Sensor Input Connection Diagram
Open CollectorType
Sensor
Device
Sensor
Power
Supply
Website: www.Veilux.net Phone# 1-800-510-6528
Rev.1.0 (April 2011)
21
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O,
D136X-I/O, D136X With WDR-I/O, D137X-I/O
I= Indoor D= Outdoor
3. Bracket Installation
3.1. Veilux VPIP(MP)
3 .
1 .
1 .
.
B a s i c C o m p o n e n t t s & M o u n t i i n g A c c e s s o r i i e s
3 .
1 .
2 .
.
P r e p a r r a t t i i o n
1. Open the Dome Cover by unscrewing with wrench.
Website: www.Veilux.net Phone# 1-800-510-6528
Rev.1.0 (April 2011)
22
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O,
D136X-I/O, D136X With WDR-I/O, D137X-I/O
I= Indoor D= Outdoor
2. Configure the DIP Switch by referring Appendix.
- When using system controller for the control of the dome, always set the RS-485 communication channel to be : 2400 bps, 8 bit, 1 stop bit, no parity.
3. Place the Dome Cover and screw.
Website: www.Veilux.net Phone# 1-800-510-6528
Rev.1.0 (April 2011)
23
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O,
D136X-I/O, D136X With WDR-I/O, D137X-I/O
I= Indoor D= Outdoor
3 .
1 .
3 .
.
I I n s t t a l l l a t t i i o n u s i i n g W a l l l l i n g M o u n t t T y p e
The wall should be strong enough to hold 4 times of the weight of the camera (5.3 KG). This means that the wall should withstand weight of 21.2 KGs in the minimum.
1. Pass the combined cable through the inside Cable Gland.
CABLE GLAND COMBINED CABLE
2. Fix the end of Cable Gland on the bottom case and coat the attached line between top & bottom of Cable Gland bottom case with silicone. For the installation at Bottom of Bracket, Gland Cable
Installation is not required(refer to the below Fig).
Website: www.Veilux.net Phone# 1-800-510-6528
Rev.1.0 (April 2011)
24
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O,
D136X-I/O, D136X With WDR-I/O, D137X-I/O
I= Indoor D= Outdoor
Hidden Cable Exposed Cable
3. Connect Sun-Visor with Wall Mounting Bracket. (1)
4. After connecting Product and Cable, install the product by inserting Product into internal fixing hole of housing and turning in clockwise. (2)
5. Assemble the Bubble. (3)
Website: www.Veilux.net Phone# 1-800-510-6528
Rev.1.0 (April 2011)
25
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O,
D136X-I/O, D136X With WDR-I/O, D137X-I/O
I= Indoor D= Outdoor
3.2 Veilux VPIPI(MP)
3 .
2 .
1 .
.
P r e p a r r a t t i i o n
1. Open the Dome Cover by unscrewing with wrench.
2. Configure the DIP Switch by referring Appendix.
- When using system controller for the control of the dome, always set the RS-485 communication channel to be : 2400 bps, 8 bit, 1 stop bit, no parity.
Website: www.Veilux.net Phone# 1-800-510-6528
Rev.1.0 (April 2011)
26
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O,
D136X-I/O, D136X With WDR-I/O, D137X-I/O
I= Indoor D= Outdoor
3. Place the Dome Cover and screw.
3 .
2 .
2 .
.
I I n s t t a l l l a t t i i o n u s i i n g C e i i l l i n g M o u n t t T y p e
Ceiling board should be strong enough to hold the weight of approx.. 2Kg.
Website: www.Veilux.net Phone# 1-800-510-6528
Rev.1.0 (April 2011)
27
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O,
D136X-I/O, D136X With WDR-I/O, D137X-I/O
I= Indoor D= Outdoor
3 .
2 .
3 .
.
I I n s t t a l l l a t t i i o n u s i i n g E m b e d d e d M o u n t t T y p e
1. Prepare 190mm Diameter Hole on the ceiling.
2. Place Safety Wire between suspension and Safety Ire Hole to prevent falling-off.
3. Fold the Lock Lever and insert the bracket into the ceiling whole.
4. Fix the bracket to the ceiling with screws.
Website: www.Veilux.net Phone# 1-800-510-6528
Rev.1.0 (April 2011)
28
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O,
D136X-I/O, D136X With WDR-I/O, D137X-I/O
I= Indoor D= Outdoor
Prepare 190mm Diameter Hole on the
Ceiling.
Place Safety Wire between suspensions and Safety Wire Hole to prevent falling- off.
Fold the Lock Lever and insert the Bracket into the Ceiling Hole.
Fix the Bracket to the Ceiling with Screws.
5. Insert the Camera into the Mount.
6. Apply screw to fix the Camera.
7. Place the cover to finish the installation.
Website: www.Veilux.net Phone# 1-800-510-6528
Rev.1.0 (April 2011)
29
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O,
D136X-I/O, D136X With WDR-I/O, D137X-I/O
I= Indoor D= Outdoor
Website: www.Veilux.net Phone# 1-800-510-6528
Rev.1.0 (April 2011)
30
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O,
D136X-I/O, D136X With WDR-I/O, D137X-I/O
I= Indoor D= Outdoor
4. Installation
4 .
1 .
R e q u i r e d S y s t t e m S p e c i f i c a t i o n
Required Specification of PC for Camera Configuration & Control.
Class Recommendation
CPU
RAM
Graphic Card
Pentium-4 3Ghz
1GB
Higher than ATI Chip-Set based 64M
Remark
1600x1200(UXGA)
LAN Card
OS
Higher than 100Mbps
Windows XP/ Vista/ 7 (32 Bit)
Web Browser Higher than Internet Explorer 6.0
* * Operating Systems supported: Windows 2000 Professional, Windows XP / Vista / 7 (32 Bit)
Website: www.Veilux.net Phone# 1-800-510-6528
Rev.1.0 (April 2011)
31
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O,
D136X-I/O, D136X With WDR-I/O, D137X-I/O
I= Indoor D= Outdoor
4 .
.
2 .
.
Q u i i c k I
I n s t t a l l l l a t t i i o n G u i i d e
Fig 4-1. LAN Cable Connection Diagram
1. Connect PC and Veilux VPIP-D1XXX-O / VPIP-D1XXX-I to Network Device(HUB)
I. Prepare a PC which needs to be connected to Network.
II. Connect PC (or Lab-Top) with Product as Fig 4-1.
Power will be applied to product separately via Power Device (AC Adaptor).
2. IP Camera Network Configuration using IP Installer
Run the CD and Install IP Installer included in CD. Once install IP Installer, “WinPcap” will be installed. If not install “WinPCap”, IP Installer won’t operate.
.
For the Network Configuration of product, IP Installer should be higher than 3.0.1 Version.
For the Window 7 User,”WinPCap” should be higher than 4.0 Version.
1. Run IP Installer > Select Network Adaptor > Click OK.
2. If Configuration Window open, Click ① > Double Click the relevant product at ② > Fill in ④ >
Configure ⑤ > Fill in ⑥ or ⑧.
3. If Configuration is completed, Click Set Button ⑨ to apply Configuration.
4. Access to Camera Admin Page by clicking ⑩.
Website: www.Veilux.net Phone# 1-800-510-6528
Rev.1.0 (April 2011)
32
2
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O,
D136X-I/O, D136X With WDR-I/O, D137X-I/O
I= Indoor D= Outdoor
3
1
9
10
4
7
5
6
8
If you click each field of ③, you can use sort function. For the detail, refer to IP Installer
Manual.
You can select the most appropriate LAN, ADSL, Static /
Dynamic IP per Cable to user’s circumstance via ⑤ menu. In case of selecting Dynamic (Automatic)IP, ⑥ menu will be deactivated, In case of ADSL, please insert User Name and Password provided from ISP in each field of ⑧.
For DDNS Service,
Insert mgmt.net-video.net in ⑦ > Please configure to be registered on DDNS by marking
Check Box.
You can use after Member Registration on Management Site http://www.net-video.net/.
3. Remote Connection to IP Camera
I. Connection via Web Viewer
Website: www.Veilux.net Phone# 1-800-510-6528
Rev.1.0 (April 2011)
33
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O,
D136X-I/O, D136X With WDR-I/O, D137X-I/O
I= Indoor D= Outdoor
Web View is the simplest method to connect to product via internet explorer. Once you insert ”
http://IP_address:HTTP_port _number
” into Internet Explorer, you can access to the relevant product.
For the use of Web Viewer, Active-X module should be installed.
If internet access is available, you can download it by accessing Camera or if you install NVR-
Pro, Active-X module will be installed together.
Fig 4-2. Web Viewer Connection
Basic ID / Password of Admin Tool :
root / admin
Some units also may have
User Name and Password is set as ‘ root ’ and ‘ dw2001 ’
Website: www.Veilux.net Phone# 1-800-510-6528
Rev.1.0 (April 2011)
34
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O,
D136X-I/O, D136X With WDR-I/O, D137X-I/O
I= Indoor D= Outdoor
II. Connection via NVXR-64
NVXR-64 is a CMS program to connect several IP Cameras and/or Video Servers. Once you run
NVXR-64 after installing on the remotely located PC, you can monitor real-time Video/Audio on the PC by accessing to IP Camera via IP Address assigned to each IP Camera. For the access to Product by using NVXR-64, you have to configure all required information at NVXR-64.
For the detail, please refer to [NVXR-64 User Manual].
Admin Page Button
Fig 4-3. NVXR-64
4. Initial Configuration by connecting Admin Mode
All Parameters of Veilux VPIP-D1XXX-O / VPIP-D1XXX-I is initially set as factory default. So you must change them with appropriate value to your network configuration by accessing via Admin Tool. Admin Tool Access
Method is as below.
Http://[IP Address]:[HTTP Port No.]/ admin.htm
Admin Tool Access ID / Password:
root / admin
. As it is Default Value, please change them. For the detailed
Some units also may have
User Name and Password is set as ‘ root ’ and ‘ dw2001 ’
Website: www.Veilux.net Phone# 1-800-510-6528
Rev.1.0 (April 2011)
35
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O,
D136X-I/O, D136X With WDR-I/O, D137X-I/O
I= Indoor D= Outdoor
5. Trouble Shooting
5 .
1 .
N o V i i d e o o n V i i e w e r r
Network Connection Status Check(Ping Test)
You can check the Network Connection Status by doing Ping Test.
- Start > Run > cmd > Ping IP Address (EX>ping 172.16.42.51).
-
If you get the response such as “Reply from~”, Network Configuration & Connection Status is good.
Please re-try to access or refer to other trouble shooting category. (
1
).
-
If you get the response such as “Request timed out”, Network Configuration & Connection Status is in problem. Please check the Network Cable and Configuration. (
2
)
1 2
Website: www.Veilux.net Phone# 1-800-510-6528
Rev.1.0 (April 2011)
36
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O,
D136X-I/O, D136X With WDR-I/O, D137X-I/O
I= Indoor D= Outdoor
5 .
.
2 .
.
W i i n d o w s v i i s t t a a n d W i i n d o w s 7 U s e r r f f o r r R e c o r r d & C a p t t u r r e
P r r o b l l e m
For the use of Video Recording & Capture function on NVR-Pro and Web Viewer, Windows Vista and
Windows 7 Users are required to configure “User Account Configuration” and “Program Execution
Entitlement Configuration”. If not configure, Recorded File won’t be generated or Captured Image on Web
Viewer won’t be saved.
Windows Vista Configuration
1. User Account Configuration
1) Select “User Account” on Control Panel
2) Select “Turn User Account Control on or off”
3) Uncheck
“Use User Account Control to help protect your computer”.
2. Program Execution Entitlement Configuration
1) Select “NVXR-64” icon on the wallpaper.
2) Select “Properties” menu popped up by clicking right button on Mouse.
3) Select Check Box of “Run this program as an administrator” from the compatibility Tap.
Website: www.Veilux.net Phone# 1-800-510-6528
Rev.1.0 (April 2011)
37
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O,
D136X-I/O, D136X With WDR-I/O, D137X-I/O
I= Indoor D= Outdoor
Windows 7 Configuration
1. User Account Configuration
1) Select “User Account” on Control Panel
2) Select “Change User Account Control Setting”
3) Set the Alarm Level at the lowest “Never Notify”
Website: www.Veilux.net Phone# 1-800-510-6528
Rev.1.0 (April 2011)
38
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O,
D136X-I/O, D136X With WDR-I/O, D137X-I/O
I= Indoor D= Outdoor
2. Program Execution Entitlement Configuration
1) S elect “NVXR-64” icon on the wallpaper
2) Select “Properties” menu popped up by clicking right button on Mouse
3) Select Check Box of “Run this program as an administrator” from the compatibility Tap.
Website: www.Veilux.net Phone# 1-800-510-6528
Rev.1.0 (April 2011)
39
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O,
D136X-I/O, D136X With WDR-I/O, D137X-I/O
I= Indoor D= Outdoor
5 .
.
3 T e c h n i i c a l l
I
I n q u i i r r y
Please contact to your supplier if you still have problem even taking all trouble shootings.
For the quickest solution, please prepare all information below;
1. Product Model Name
2. Serial No. & Mac Address
3. Date of Purchase
4. Summary of Problem
5. Error Message
Website: www.Veilux.net Phone# 1-800-510-6528
Rev.1.0 (April 2011)
40
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O,
D136X-I/O, D136X With WDR-I/O, D137X-I/O
I= Indoor D= Outdoor
6. Appendix
6.1. FAN & Heater
FAN & Heater is inside Housing of Outdoor Speed Dome and will operate with AC24V.
Cablings for the Fan & Heater are completed in the Factory
. Detailed Specification
Category
Heater Control Temp.
FAN Control Temp.
Operational Temp.
Operational Humidity
Water-Proof
Materials
Appearance
Power Consumption
Power
Weight
Description
On: below 10℃, Off: over 15℃
On: over 45℃, Off: below 35℃
-40℃ ~ +60℃
Below 90%
IP 66
Poly Carbonate (Bubble), Aluminum (Body)
253Ø(diameter) x 307mm(Height) x 190Ø(Bubble)
18W Max (With Camera: 43W Max)
AC 24V 1A, 60 / 50Hz (AC24V 2A with camera)
3.4kg (including Camera : 5.3kg)
Website: www.Veilux.net Phone# 1-800-510-6528
Rev.1.0 (April 2011)
41
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O,
D136X-I/O, D136X With WDR-I/O, D137X-I/O
I= Indoor D= Outdoor
6.2. DIP Switch Setting
A. ID Configuration
* Factory Default: Camera ID = 1
(1-ON, 0-OFF)
DIP SW
11010000
00110000
10110000
01110000
11110000
00001000
10001000
01001000
11001000
00101000
10101000
10000000
01000000
11000000
00100000
10100000
01100000
11100000
00010000
10010000
01010000
11
12
13
14
15
16
7
8
9
10
17
18
19
20
21
ID VALUE
1
2
3
4
5
6
50
51
52
53
54
55
46
47
48
49
56
57
58
59
60
ID VALUE
40
41
42
43
44
45
DIP SW
00010100
10010100
01010100
11010100
00110100
10110100
01110100
11110100
00001100
10001100
01001100
11001100
00101100
10101100
01101100
11101100
00011100
10011100
01011100
11011100
00111100
89
90
91
92
93
94
85
86
87
88
95
96
97
98
99
ID VALUE
79
80
81
82
83
84
DIP SW
11110010
00001010
10001010
01001010
11001010
00101010
10101010
01101010
11101010
00011010
10011010
01011010
11011010
00111010
10111010
01111010
11111010
00000110
10000110
01000110
11000110
Website: www.Veilux.net Phone# 1-800-510-6528
Rev.1.0 (April 2011)
42
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O,
D136X-I/O, D136X With WDR-I/O, D137X-I/O
I= Indoor D= Outdoor
123
124
125
126
127
128
129
130
131
132
133
134
119
120
121
122
37
38
39
118
33
34
35
36
29
30
31
32
22
23
24
25
26
27
28
10010101
01010101
11010101
00110101
10110101
01110101
11110101
00001101
10001101
01001101
11001101
00101101
00110010
10110010
01110010
00100101
10100101
01100101
11100101
00010101
10111100
01111100
11111100
00000010
10000010
01000010
11000010
00100010
10100010
01100010
11100010
00010010
10010010
01010010
11010010
11011110
00111110
10111110
01111110
11111110
00000001
10000001
01000001
11000001
00100001
10100001
01100001
10100100
01100100
11100100
01101110
11101110
00011110
10011110
01011110
01101000
11101000
00011000
10011000
01011000
11011000
00111000
10111000
01111000
11111000
00000100
10000100
01000100
11000100
00100100
169
170
171
172
173
174
175
176
177
178
179
180
165
166
167
168
76
77
78
164
72
73
74
75
68
69
70
71
61
62
63
64
65
66
67
11101011
00011011
10011011
01011011
11011011
00111011
10111011
01111011
11111011
00000111
10000111
01000111
11001110
00101110
10101110
01001011
11001011
00101011
10101011
01101011
00100110
10100110
01100110
11100110
00010110
10010110
01010110
11010110
00110110
10110110
01110110
11110110
00001110
10001110
01001110
215
216
217
218
219
220
221
222
223
224
225
226
211
212
213
214
115
116
117
210
111
112
113
114
107
108
109
110
100
101
102
103
104
105
106
Website: www.Veilux.net Phone# 1-800-510-6528
Rev.1.0 (April 2011)
43
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O,
D136X-I/O, D136X With WDR-I/O, D137X-I/O
I= Indoor D= Outdoor
01001111
11001111
00101111
10101111
01101111
11101111
00011111
10011111
01011111
11011111
00111111
10111111
01111111
11111111
11000111
00100111
10100111
01100111
11100111
00010111
10010111
01010111
11010111
00110111
10110111
01110111
11110111
00001111
10001111
200
201
202
203
196
197
198
199
204
205
206
207
208
209
192
193
194
195
188
189
190
191
181
182
183
184
185
186
187
154
155
156
157
150
151
152
153
158
159
160
161
162
163
146
147
148
149
142
143
144
145
135
136
137
138
139
140
141
01101001
11101001
00011001
10011001
01011001
11011001
00111001
10111001
01111001
11111001
00000101
10000101
01000101
11000101
11100001
00010001
10010001
01010001
11010001
00110001
10110001
01110001
11110001
00001001
10001001
01001001
11001001
00101001
10101001
00100011
10100011
01100011
11100011
00010011
10010011
01010011
11010011
00110011
10110011
01110011
11110011
00001011
10001011
10101101
01101101
11101101
00011101
10011101
01011101
11011101
00111101
10111101
01111101
11111101
00000011
10000011
01000011
11000011
246
247
248
249
242
243
244
245
250
251
252
253
254
255
238
239
240
241
234
235
236
237
227
228
229
230
231
232
233
Website: www.Veilux.net Phone# 1-800-510-6528
Rev.1.0 (April 2011)
44
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O,
D136X-I/O, D136X With WDR-I/O, D137X-I/O
I= Indoor D= Outdoor
B. PROTOCOL
Set by 3 rd
, 4th Switch of DIP Switch 2.
Factory Default: Pelco-D & Pelco-P (Auto)
DIP SW2 - 3 rd
4 th
OFF / OFF
ON / ON
C. BAUD RATE SETTING
Set by 7 th
, 8th Switch of DIP Switch 2.
Changeable Speed: 4800bps, 9600bps
Factory Default: 2400bps.
DIP SW2-7 th
OFF
OFF
ON
ON
* 5 th
, 6 th
Switch of DIP Switch 2 is not used.
DIP SW2-8 th
OFF
ON
OFF
ON
Pelco-D or Pelco-P
Maxpro protocol
BAUD RATE
Not Used
2400bps
4800bps
9600bps
Website: www.Veilux.net Phone# 1-800-510-6528
Rev.1.0 (April 2011)
45

Public link updated