NS Series

Add to my manuals
22 Pages

advertisement

NS Series | Manualzz

Programmable Terminals

NS Series

Even Simpler Equipment Operation with Outstanding Synergy.

5.7

inches

Color TFT

STN monochrome

10.4

inches

Color TFT

15

inches

Color TFT

12.1

inches

Color TFT

8.4

inches

Color TFT

Features

• 5.7 to 12.1 inch sizes are available.

• A hand-held version of the NS5 is now available to perform operations at the production site. The NS-series PT's have a complete set of functions that can be used at the production site.

• The Smart Active Parts(SAP Library) makes it easy to connect to OMRON PLCs and components,

OMRON provides a development environment that requires with no programming and no screen designing.

• When an error occurs in a Unit in the OMRON PLCs, the Troubleshooter SAP Library provides an easy-tounderstand explanation of the cause of the error as well as the countermeasures.

• Ladder Monitor come as a Standard Feature. The ladder program can be monitored onsite without a laptop!

Ladder monitor lets you monitor PLC program status, search for addresses or instructions, monitor multiple I/O points, and much more.

• Provides the FA integrated tool package "CX-One" for a Screen Design Software Integrated Simulation come as a

Standard Feature. The integrated simulation function simulates ladder programs and screen data simultaneously even without the actual hardware.

• Screens support 42 languages and the Support Software supports eight. System messages can be displayed in eight languages.

• Single Port Multi Access (SPMA) come as a Standard Feature. The ladder program and screen data can be transferred from a single port!

• Connectable PLCs and devices appear one after another.

Has become connectable with the PLCs of Mitsubishi Electric Corporation and the Inverters of OMRON

Corporation.

Sysmac is a trademark or registered trademark of OMRON Corporation in Japan and other countries for OMRON factory automation products.

Windows is registered trademarks of Microsoft Corporation in the USA and other countries.

EtherCAT is a registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany.

Other company names and product names in this document are the trademarks or registered trademarks of their respective companies.

1

2

NS

Series

Network

Provides serial NT Link communications supporting both 1:1 and 1:N connections. The NT Link has more efficient communications than Host Link and its capabilities are especially apparent in applications with multiple PTs connect to the PLC. The NS-series PTs can also support communications with multiple PLCs and multiple NS-series PTs through Controller Link and Ethernet connections, so the network can be configured freely to match the requirements and scale of the application. In addition, using the NS-Runtime makes it possible to monitor machine status and log data from the host.

[Example NS-series Network

Configuration]

1

EtherNet/IP (Tag access)

4

EtherNet/IP, Ethernet

CS/CJ-series

PLC

Personal computer

Software for Machine Monitoring and

Data Logging

(sold separately)

NS-series PT

2

Serial connection

3

Controller Link

5

Connections across network levels

CS/CJ-series

PLC

CS/CJ-series

PLC

NS-series PT

2

Serial connection

CS/CJ-series PLC

NS-series PT

NS-series PT

Configuration of CJ2 series and NJ series

1 EtherNet/IP Connection (Tag accesses)

If an Ethernet-compatible NS-series PT is used, the PT can connect to a Controller with built-in EtherNet/IP and an Option Unit is not needed to connect at the PT.

NS-series PT

Personal computer

NS-series PT

Controller Controller Controller

NS

Series

Configuration of CS series, CJ series and CP series

2 Serial connection

1:1 NT Link or Host Link

NS:PLC = 1:1

Connecting with the PLC through port A or port B

NS-series PT

PLC

NS:PLC = 1:2

PLC

NS-series PT

PLC

1:N NT Link

NS:PLC ratio = 8:1 max.

Up to 8 NS-series PTs can be connected to each of the PLC's RS-232C/RS-422A ports.

NS-series

PT

NS-series

PT

NS-series

PT

PLC

NS-AL002 Converter

(Converts between

RS-232C and RS-422A.)

3 Controller Link Connection

The PT can be connected to an OMRON Controller Link network by mounting a Controller Link Interface Unit.

NS-CLK21

NS Series

PT

PLC PLC PLC

If a Controller Link connection is used, data links can be set between PLCs and multiple

PLCs can be monitored/set from the NS-series PT's screen.

Baud rate

2 Mbps (500 m max.)

1 Mbps (800 m max.)

500 kbps (1 km max.)

Max. number of nodes: 32 nodes

4 EtherNet/IP or Ethernet Connection

If an Ethernet-compatible NS-series PT is used, the PT can connect to a PLC with an Ethernet Unit and an Option Unit is not needed to connect at the PT.

NS Series PT

Personal computer

NS Series PT

PLC PLC PLC

5 Connections Over Network Levels

The NS-series PTs can connect to a variety of devices in the network, through as many as 3 network levels.

For example, if SAP (Smart Active Parts) are being used, an NS-series PT connected by Ethernet can be used to monitor the information in a PLC connected through Controller Link as well as the information in the DeviceNet Slaves connected to that PLC.

NS Series

PT

NS Series

PT

Ethernet

PLC

Seamless and

Program-less

Seamless and

Program-less

Controller Link

PLC PLC

DeviceNet

3

4

NS

Series

System Configuration

NS5/NS8/NS10/NS12/NS15

Memory Card

Interface

OMRON

Memory Card

Ethernet port

USB

Slave

USB

Master

RS-232C port

RS-232C port

RS-422A Conversion Unit

CJ1W-CIF11

NS-AL002

Note:

A Conversion Unit is not required to connect to the RS-422A/485 serial interface of the NS15.

OMRON PLC

PT-to-PLC Connecting Cable

XW2Z-200T (Length: 2 m)

XW2Z-500T (Length: 5 m)

RS-232C

Bar Code Reader

Recommended: OMRON

V520-RH21-6

RS-232C

Screen transfer cable

XW2Z-S002 (Length: 2 m)

Screen transfer cable

XW2Z-S002 (Length: 2 m)

USB Serial Conversion Cable

CS1W-CIF31

USB

Personal computer

Memory link connection

Micro-computer board, personal computer, etc.

CompoWay/F connection

Temperature

Controller

Modbus (MEMOBUS)-RTU connection

RS-422A

OMRON

PLC

Inverter

Standard USB cable

Commercially available.

Standard USB cable

Commercially available.

Standard USB cable

Commercially available.

PictBridge

USB

USB

PictBridge-compatible printer

WE70

Wireless

WE70

Ethernet

Ethernet

EtherNet/IP

OMRON

PLC

OMRON

PLC

OMRON

Controller

Personal computer

Ethernet

Personal computer

NS

Series

Expansion Bus Interface

Any one of the following Units can be mounted to the expansion bus interface.

Controller Link Interface Unit

NS-CLK21

Controller Link

Video Input Unit

NS-CA001

NTSC/PAL

RGB/Video Input Unit

NS-CA002

NTSC/PAL

RGB output

Expansion bus interface

Note:

Video Input Units and RGB Video Input Units cannot be used with some models.

Multi-vendor

PLC

Vision

Sensor

Personal computer

RS-232C port

RS-232C port

RS-232C

Computer Link Unit

Mitsubishi A-series PLC

Function Extension Board or Mitsubishi

FX-series PLC Communications Adapter

Mitsubishi FX-series PLC

Serial Communications Unit

Mitsubishi QnA-series PLC

Serial Communications Unit

Mitsubishi Q-series PLC

Computer Link Module

Yokogawa’s FA-M3(R) Series

SIMATIC S7 HMI Adapter

Siemens S7-300-series PLC

Serial Communications Module

Yaskawa MP-series PLC

RS-422A

Conversion Unit

CJ1W-CIF11

NS-AL002

Note:

A Conversion Unit is not required to connect to the

RS-422A/485 serial interface of the NS15.

RS-422A/485 (See note.)

Screen transfer cable

XW2Z-S002 (Length: 2 m)

Rockwell (Allen-Bradley)

SLC500/Micrologix/ControlLogix/

CompactLogix/PLC-5-series PLC

Modbus device (RTU mode)

Computer Link Unit

Mitsubishi A-series PLC

Function Extension Board or Mitsubishi

FX-series PLC Communications Adapter

Mitsubishi FX-series PLC

Serial Communications Unit

Mitsubishi QnA-series PLC

Serial Communications Unit

Mitsubishi Q-series PLC

Computer Link Module

Yokogawa’s FA-M3(R) Series

Serial Communications Module

Yaskawa MP-series PLC

Rockwell (Allen-Bradley)

PLC-5-series PLC

Modbus device (RTU mode)

Note:

Whether an RS-422A or RS-485 connection is supported depends on the device that you are connecting to.

For details, refer to the Connectable Devices page or NS-Series Programmable Terminals HOST CONNECTION MANUAL Multivendor

Connection (Cat.V092).

5

6

NS

Series

NSH5 Hand-held PT

USB

Commercially available USB cable.

USB Slave

Memory

Card interface

NSH5 PT

UL-listed Cables

OMRON

Memory Card

RS-232C cable

RS-422A cable

RS-232C Connecting Cable for the NSH5

NSH5-232CW-3M (Length: 3 m)

RS-232C Connecting Cable for the NSH5

NSH5-232CW-10M (Length: 10 m)

RS-422A Connecting Cable for the NSH5

NSH5-422CW-10M (Length: 10 m)

RS-232C

RS-422A

RS-232C cable

RS-422A cable

RS-232C Connecting Cable for the NSH5

NSH5-232UL-3M (Length: 3 m)

RS-232C Connecting Cable for the NSH5

NSH5-232UL-10M (Length: 10 m)

RS-422A Connecting Cable for the NSH5

NSH5-422UL-10M (Length: 10 m)

RS-232C

RS-422A

Personal computer

PLC

PLC

PLC

PLC

USB

USB Slave

Memory

Card interface

NSH5 PT

Commercially available USB cable.

OMRON

Memory Card

Personal computer

Removable Box Connected

RS-232C cable

RS-232C Connecting Cable for the NSH5

NSH5-232CN-3M (Length: 3 m)

RS-232C Connecting Cable for the NSH5

NSH5-232CN-10M (Length: 10 m)

Removable Box

RS-422A

PLC

System Configuration

(Removable Box Connected)

Up to eight NSH5s can be connected at a time.

NSH5 (See note.)

PLC

Removable

Box

Control panel

RS-422A connection (Total cable length: 500 m max.)

RS-232C connection

(Cable length: 3 or 10 m)

Up to 15 Removable Boxes can be connected.

Note:

Before removing the NSH5 from the Removable Box, be sure to first turn OFF the power supply key on the Removable Box.

NS

Series

Ordering Information

International Standards

• The standards are availabled as follows: U: UL, U1: UL (Class I Division 2 Products for Hazardous Locations), C: CSA, UC: cULus, UC1: cULus

(Class I Division 2 Products for Hazardous Locations), CU: cUL, N: NK, L: Lloyd, and CE: EC Directives.

• Contact your OMRON representative for further details and applicable conditions for these standards.

Programmable Terminals

Product name

NS5-V2 *1

NS8-V2

NS10-V2

NS12-V2

Effective display area

5.7-inch *2

TFT color

LED backlight

5.7-inch *2

High-luminance

TFT color

LED backlight

8.4-inch *2

TFT

LED backlight

10.4-inch *2

TFT

LED backlight

12.1-inch *2

TFT

LED backlight

Specifications

Number of dots

320 × 240 dots

640 × 480 dots

640 × 480 dots

800 × 600 dots

Ethernet

No

Yes

No

Yes

No

Yes

No

Yes

No

Yes

Case color

Ivory

Black

Ivory

Black

Ivory

Black

Ivory

Black

Ivory

Black

Ivory

Black

Ivory

Black

Ivory

Black

Ivory

Black

Ivory

Black

Model

NS5-SQ10-V2

NS5-SQ10B-V2

NS5-SQ11-V2

NS5-SQ11B-V2

NS5-TQ10-V2

NS5-TQ10B-V2

NS5-TQ11-V2

NS5-TQ11B-V2

NS8-TV00-V2

NS8-TV00B-V2

NS8-TV01-V2

NS8-TV01B-V2

NS10-TV00-V2

NS10-TV00B-V2

NS10-TV01-V2

NS10-TV01B-V2

NS12-TS00-V2

NS12-TS00B-V2

NS12-TS01-V2

Standards

UC1, CE,

N, L,

UL Type4

UC1, CE,

N, L

UC1, CE,

N, L,

UL Type4

NS12-TS01B-V2

NS15-V2

15-inch

TFT

1,024 × 768 dots Yes

Silver

NS15-TX01S-V2

Black

NS15-TX01B-V2

NSH5-V2 *1

Hand-held

5.7-inch

TFT

320

× 240 dots

No

Black (Emergency stop button: Red)

Black

(Stop button: Gray)

NSH5-SQR10B-V2

NSH5-SQG10B-V2

UC, CE

*1. As of July 2008, the image memory has been increased to 60 MB.

*2. Lot No. 15Z0 or later of NS5 color-type models, Lot No. 28X1 or later of NS8 models, Lot No. 11Y1 or later of NS10 models, Lot No. 14Z1 or later of NS12 models, LotNo.31114K or later of NS15 models.

NS-Runtime

Product name

NS-Runtime

Specifications

NS-Runtime Installer, PDF manual, hardware key (See note.)

1license

3 licenses

10 licenses

Media

CD

Model

NS-NSRCL1

NS-NSRCL3

NS-NSRCL10

Note:

A hardware key (USB dongle) is required for NS-Runtime operation.

System Requirements

Item

OS

CPU

Memory size

Specifications

Windows XP (Service Pack 3 or higher), Vista, 7 or 8 (Support 64-bit version for Windows 7 and Windows 8.)

Celeron, 1.3 GHz or higher (Recommended)

HDD: 50 MB min., RAM: 512 MB min. (Windows 7: 1 GB min.).

50 MB is required for the Runtime alone. (An additional 280 MB is required if CX-Server is not already installed.)

Standards

---

7

8

NS

Series

Software

How to Select Required Support Software for Your Controller

The required Support Software depends on the Controller to connect. Please check the following table when purchasing the Support Software.

Item

Controller

Programmable Terminals

Software

Omron PLC System

CS, CJ, CP, and other series

NS-series

FA Integrated Tool Package CX-One

Omron Machine Automation Controller System

NJ-series

NS-series with an Ethernet port

Automation Software Sysmac Studio

FA Integrated Tool Package CX-One

Product name

Specifications Number of licenses

Media

Model Standards

FA Integrated

Tool Package

CX-One Ver.4.

@

The CX-One is a comprehensive software package that integrates Support

Software for OMRON PLCs and components.

CX-One runs on the following OS.

Windows XP (Service Pack 3 or higher, 32-bit version) / Windows Vista (32-bit/

64-bit version) / Windows 7 (32-bit/64-bit version) / Windows 8 (32-bit/64-bit version) / Windows 8.1 (32-bit/64-bit version)

CX-One Version 4.

@ includes CX-Designer Ver.3.@.

For details, refer to the CX-One catalog (Cat. No. R134)

*1. Multi licenses are available for the CX-One (3, 10, 30, or 50 licenses).

*2. The CX-One is also available on CD (CXONE-AL@@C-V4).

license

*1

DVD

*2

CXONE-AL01D-V4

Automation Software Sysmac Studio

Please purchase a DVD and required number of licenses the first time you purchase the Sysmac Studio. DVDs and licenses are available individually. Each model of licenses does not include any DVD.

---

Specifications

Product name

Number of licenses

Media

Model Standards

Sysmac Studio

Standard Edition

Ver.1.

@

The Sysmac Studio provides an integrated development environment to set up, program, debug, and maintain NJ-series Controllers and other Machine

Automation Controllers, as well as EtherCAT slaves.

Sysmac Studio runs on the following OS.

Windows XP (Service Pack 3 or higher, 32-bit version) / Windows Vista (32-bit version) / Windows 7 (32-bit/64-bit version) / Windows 8 (32-bit/64-bit version) /

Windows 8.1 (32-bit/64-bit version)

The Sysmac Studio Standard Edition DVD includes Support Software to set up

EtherNet/IP Units, DeviceNet slaves, Serial Communications Units, and

Support Software for creating screens on HMIs (CX-Designer).

For details, refer to the Sysmac Integrated Catalogue (P072).

- (Media only) DVD

1 license* ---

SYSMAC-SE200D

SYSMAC-SE201L

Note: 1.

To connect the NJ5 Controller, NS system version 8.5 or higher is required. CX-Designer version 3.3 or higher is also required.

2.

To connect the NJ3 Controller, NS system version 8.61 or higher is required. CX-Designer version 3.4 or higher is also required.

* Multi licenses are available for the Sysmac Studio (3, 10, 30, or 50 licenses).

---

---

NS

Series

Cable

Product name

Cable *1

Specifications

Screen transfer cable for DOS/V (CX-Designer ↔ PT)

USB-Serial Conversion Cable

Length: 2 m

Length: 0.5 m

Model

XW2Z-S002

Standards

---

N

CS1W-CIF31

USB relay cable Length: 1 m

NS-USBEXT-1M

NSH5 Cables

UL-compliant

NSH5 Cable

PT-to-PLC

Connecting Cable *2

NSH5 Removable Box

Cable

RS-422A cable (loose wires + D-Sub 9-pin)

RS-232C cable (loose wires + D-Sub 9-pin)

RS-232C cable (loose wires + D-Sub 9-pin)

RS-422A cable (loose wires)

RS-232C cable (loose wires + relay cable)

RS-232C cable (loose wires + relay cable)

PT connection: 9 pins

PLC connection: 9 pins

PT connection: 9 pins

PLC peripheral port

RS-232C Cable (connectors)

Length: 10 m

Length: 3 m

Length: 10 m

Length: 10 m

Length: 3 m

Length: 10 m

Length: 2 m

Length: 5 m

Length: 2 m

Length: 5 m

Length: 3 m

Length: 10 m

NSH5-422CW-10M

NSH5-232CW-3M

NSH5-232CW-10M

NSH5-422UL-10M

NSH5-232UL-3M

NSH5-232UL-10M

XW2Z-200T

XW2Z-500T

XW2Z-200T-2

XW2Z-500T-2

NSH5-232CN-3M

NSH5-232CN-10M

NSH5-AL001

CU

NSH5 Removable Box

---

NSH5 Wall-mounting

Bracket

---

NSH5-ATT02

NSH5 Visor

---

NSH5-ATT01

*1. Use a standard USB Type A male to Type B type male Cable to connect the NS series PT to a personal computer (CX-Designer).

Use a standard USB cable to connect the NS series PT to a PictBridge-compatible printer. USB cable type depends on the printer.

*2. To connect the NS series PT to NJ series Controller, using a commercially available 10/100-BASE-TX twisted-pair cable.

For detail, refer to the NS series SETUP MANUAL (Cat. No.V083).

---

---

9

10

NS

Series

Options

Product name

Video

Input

Unit

Inputs: 4 channels

Signal type: NTSC/PAL

Specifications

Input channels: 2 video channels and 1 RGB channel *1

Signal type: NTSC/PAL

Special Cable for the

Console

Controller Link Interface

Unit

Cable length: 2 m

Cable length: 5 m

For Controller Link Communications

RS-422A

Adapter

Sheet/Cover *2

Transmission distance: 500 m total length

Note:

Use this model when connecting PT models without a V

Note:

PT models with the V

@ suffix can also be connected.

@ suffix.

Transmission distance: 50 m total length

Note:

Only PT models with a suffix of V

@ are connectable.

Use the NS-AL002 to connect models without a V

@ suffix.

Anti-reflection Sheets

(5 surface sheets)

Protective Covers (5 pack)

(anti-reflection coating)

Protective Covers

(1 cover included)

(Transparent)

Protective Covers

(5 covers included)

(Transparent)

Attachment

Memory

Card

NT625C/631/631C Series to NS12/10 Series

NT625C/631/631C Series to NS12/NS10 Series (Black)

NT610C Series to NS12/10 Series

NT620S/620C/600S Series to NS8 Series

NT600M/600G/610G/612G Series to NS8 Series

128 MB

256 MB

512 MB

---

Memory Card Adapter

Replacement Battery

Bar Code Reader

Battery life: 5 years (at 25°C)

CCD handheld bar code reader (RS-232C interface)

*1. One screen cannot display two video inputs simultaneously.

*2. A Chemical-resistant Cover (NT30-KBA01) is available only for the NS5.

NS15

NS12/10

NS8

NS5

NS12/10

NS8

NS5

NS15

NS12/10

NS8

NS5

Model

NS-CA001

NS-CA002

F150-VKP (2 m)

F150-VKP (5 m)

NS-CLK21

NS-AL002

CJ1W-CIF11

NS15-KBA04

NS12-KBA04

NS7-KBA04

NT30-KBA04

NS12-KBA05

NS7-KBA05

NT31C-KBA05

NS15-KBA05N

NS12-KBA05N

NS7-KBA05N

NT31C-KBA05N

NS12-ATT01

NS12-ATT01B

NS12-ATT02

NS8-ATT01

NS8-ATT02

HMC-EF183

HMC-EF283

HMC-EF583

HMC-AP001

CJ1W-BAT01

V520-RH21-6

---

CE

---

Standards

UC1, CE

---

UC1, CE

---

UC1, N,

L, CE

NS

Series

General Specifications

NS5/NS8/NS10/NS12/NS15

Series NS5-V2 NS8-V2 NS10-V2 NS12-V2

Rated power supply voltage

24 VDC

Allowable voltage range

20.4 to 27.6 VDC (24 VDC ±15%)

Power consumption

15 W max.

25 W max.

Ambient operating temperature

Storage temperature

0 to 50 °C (See note on the next page.)

Note:

The ambient operating temperature is subject to the following restrictions according to the mounting angle.

Mounting angle of 0 to 30 ° to the horizontal:

• When no Expansion Units are mounted, the operating temperature range is 0 to 45

°C.

• When a Video Input Unit or a Controller Link Interface Unit is mounted, the ambient operating temperature is 0 to 35

°C.

Mounting angle of 30 to 90

° to the horizontal: Operating temperature range of 0 to 50°C

−20 to 60 °C *1

Ambient operating humidity

35 to 85% (0 to 40

°C), 35 to 60% (40 to 50 °C) (with no condensation)

Operating environment

Noise immunity

No corrosive gases.

Conforms to IEC61000-4-4, 2 kV (power lines).

90°

Displa y s urf ace

NS15-V2

45 W max.

30°

Horizontal 0°

Vibration resistance

(during operation)

10 to 57 Hz, 0.075 mm amplitude, 57 to 150 Hz, 9.8 m/s

2

30 min each in X, Y, and Z directions

5 to 8.4 Hz, 3.5 mm single amplitude, 8.4 to 150 Hz,

9.8 m/s

2

10 min times each in X, Y, and Z directions

Shock resistance

(during operation)

Weight

147 m/s 2 3 times each in direction of X, Y, and Z

Degree of protection

Ground

Battery life

Applicable standards

1.0 kg max.

2.0 kg max.

2.3 kg max.

2.5 kg max.

Front operating panel: IP65 oil-proof type and NEMA4 UL type 4. *2

Note:

May not be applicable in locations with long-term exposure to oil.

Ground to 100 Ω or less.

5 years (at 25 °C): Replace battery within 5 days after the battery runs low (indicator lights orange).

Certified for conformance to UL 508, UL 1604, EMC Directive, NK, and LR Standards.

*1. Operate the PT within the temperature and humidity ranges shown in the right diagram.

*2. Support for NS5, NS10, NS12 and NS15.

Operation

4.2 kg max.

Storage

60

Humidity (%RH)

95%

8

0%

60%

Temperature (°C)

−20

0

0

10

20

30

40

50

10 20 30 40 50

Temperature (°C)

60 70

40%

35%

20%

8

0

10%

NSH5 Hand-held PT

Series NSH5-V2

Type

Case color

Built-in Ethernet port

5.7-inch Color TFT (Hand-held Version)

Black

No

NSH5-SQR10B-V2 (Emergency stop button: Red) NSH5-SQG10B-V2 (Stop button: Gray)

Model

Rated power supply voltage

24 VDC

Allowable voltage range

20.4 to 27.6 VDC (24 VDC ±15%)

Power consumption

10 W max.

Ambient operating temperature

0 to 40 °C

Storage temperature

Noise immunity

−20 to 60°C

Ambient operating humidity

35% to 85% (0 to 40

Operating environment

No corrosive gases.

°C) with no condensation

Common mode: 1,000 Vp-p (between power supply terminals and panel)

Normal mode: 300 Vp-p

Pulse width: 100 ns to 1 μs, Rise time: 1-ns pulse

Vibration resistance

(during operation)

10 to 57 Hz, 0.075 mm amplitude, 57 to 150 Hz, 9.8 m/s 2 30 min each in X, Y, and Z directions

Shock resistance

(during operation)

147 m/s 2 3 times each in direction of X, Y, and Z

Weight

Degree of protection

Ground

Battery life

Applicable standards

1 kg max.

Equivalent to IP65.

Ground to 100 Ω or less.

5 years (at 25 °C): Replace battery within 5 days after the battery runs low (indicator lights orange).

Certified for conformance to UL 508, EMC Directive, and EN 60204-1.

11

12

NS

Series

Performance/Specifications

NS5

Series

Model

Built-in Ethernet port

Case color

Display device

Effective display area

Display colors

Number of dots

View angle

Screen data capacity

Image data

(BMP or JPG images)

Memory Card

Ladder Monitor function

Video Input Unit support

Controller Link Interface

Unit (Wired) support

Backlight *2

Service life * 3

Brightness adjustment

Backlight error detection *5

Method

NS5-V2

NS5-SQ10-V2 NS5-SQ11-V2 NS5-SQ10B-V2 NS5-SQ11B-V2 NS5-TQ10-V2 NS5-TQ11-V2 NS5-TQ10B-V2 NS5-TQ11B-V2

No Yes No Yes No Yes No Yes

Ivory

TFT color LCD

Black

Width 117.2 × height 88.4 mm (5.7 inches)

256 colors

320 dot horizontal × 240 dot vertical

Left/right: 80 °, Top: 80°, Bottom: 60° *5

60 Mbytes

Ivory

Color High-luminance TFT *1

Black

32,768 colors

Supported

Not supported

Not supported

Not supported

75,000 hours min.

Three-level or 32-level brightness adjustment from the touch panel screen. * 4

Error is detected automatically, and the RUN indicator flashes green as notification.

Matrix resistive membrane

Touch panel

(matrix type)

Display text

Number of switches/ resolution

Input

Service life

Labels

Numerals, alarms, and character strings

Supported languages

(42 languages)

300 (20 horizontal × 15 vertical) 16 × 16 dots for each switch

Pressure-sensitive

1,000,000 touch operations.

Can be specified in CX-Designer. Font, style, and size can be specified.

Scalable Gothic: Magnification: 6 to 255 points

Rough: Magnification:

1

1

×1, 1×2, 2×1, 2×2, 3×3, 4×4, 8×8

×1, 1×2, 2×1, 2×2, 3×3, 4×4, 8×8

7-segment display: Can display only numerals, dates, and times.

Scalable Gothic, rough, standard, and fine can be used for 42 languages.

Japanese, simplified Chinese, traditional Chinese, Korean, English, French, German, Italian, Portuguese, Spain, Swedish, Dutch,

Finnish, Norwegian, Basque, Catalan, Danish, Albanian, Croatian, Czech, Hungarian, Polish, Romanian, Slovak, Slovenian,

Bulgarian, Belarusian, Russian, Serbian, Macedonian, Ukrainian, Georgian, Icelandic, Afrikaans, Faroese, Indonesian, Greek,

Turkish, Estonian, Latvian, Lithuanian, Thai (supported only with scalable Gothic font)

256 colors

Color

Font style

(only when vector font is specified)

Bold or italic

Text attributes

Flicker

Vertical alignment

Horizontal alignment

Objects supporting flicker

Top, center, or bottom

Left-justified, centered, or right-justified

Functional objects: Select from up to 10 types of registered flicker settings. The flicker speed and flicker range can be set.

Fixed objects: Select from three flicker types.

Numeral units and scale settings

1.000 max.

Alarm/event settings

5,000 max.

Expansion interface

For Expansion Interface Units

*1. NS5-TQ series (high luminance TFT) luminance is better than that of NS5-SQ series by about 110 cd/m

2 .

*2. Contact your nearest OMRON representative to replace the backlight.

*3. This is the estimated time before brightness is reduced by half at room temperature and humidity. It is not a guaranteed value.

The service life will be dramatically shortened if PT is used at low temperatures. For example, using the PT at temperatures of 0 °C will reduce the service life to approximately 10,000 hours (reference value).

*4. Lot No. 15Z0 or later of NS5 models.

*5. This function does not indicate that the service life has been reached. It detects when the backlight is not lit due to a disconnection or other errors.

Backlight error detection indicates that all backlights (2) are OFF.

NS

Series

NS8/NS10/NS12/NS15

Series

Model

Built-in Ethernet port

Case color

Display device

Effective display area

NS8-

TV00-

V2

No

Ivory

NS8-V2

NS8-

TV01-

V2

Yes

NS8-

TV00B

-V2

No

Black

NS8-

TV01B

-V2

Yes

High-definition TFT color LCD

Width 170.9

(8.4 inches)

× height 128.2 mm

NS10-

TV00-

V2

No

Ivory

V2

Yes

Width 215.2

(10.4 inches)

NS10-V2

NS10-

TV01-

NS10-

TV00B

-V2

No

Black

NS10-

TV01B

-V2

Yes

High-definition TFT color LCD

× height 162.4 mm

NS12-

TS00-

V2

No

Ivory

NS12-V2

NS12-

TS01-

V2

Yes

NS12-

TS00B

-V2

No

Black

NS12-

TS01B

-V2

Yes

High-definition TFT color LCD

Width 246.0

(12.1 inches)

× height 184.5 mm

NS15-V2

NS15-

TX01S-

V2

Yes

Silver

NS15-

TX01B-

V2

Yes

Black

High-definition TFT color LCD

Width 304.1

× height

228.1 mm

(15 inches)

Display colors

256 colors

Number of dots

View angle

640 dot horizontal

× 480 dot vertical

Left/right: 80

°, Top: 80°,

Bottom: 60

° *3

60 Mbytes

Left/right: 70

Bottom: 65

°, Top: 65°,

° *3

800 dot horizontal vertical

Left/right: 80

Bottom: 80

× 600 dot

°, Top: 80°,

° *3

1,024 dot horizontal

× 768 dot vertical

Left/right: 80

70

°, Top:

°, Bottom: 60°

Screen data capacity

Image data

(BMP or JPG images)

Memory Card

Ladder Monitor function

32,768 colors

Supported

Supported

Video Input Unit support

Supported (Image displayed via video input is 260,000 colors)

(Only RGB input is enabled.)

Controller Link Interface

Unit (Wired) support

Not supported

Service life * 2

50,000 hours min.

Backlight *1

Brightness adjustment

Supported

Three-level or 32-level brightness adjustment from the touch panel screen. * 3

Backlight error detection *4

Error is detected automatically, and the RUN indicator flashes green as notification.

Touch panel

(matrix type)

Display text

Method

Number of switches/ resolution

Input

Service life

Labels

Numerals, alarms, and character strings

Supported languages

(42 languages)

Color

Matrix resistive membrane

768 (32 horizontal

20

× 24 vertical)

× 20 dots for each switch

1,200 (40 horizontal

16

× 30 vertical)

× 16 dots for each switch

1,900 (50 horizontal

16

× 38 vertical)

× 16 dots for each switch

Analog resistive membrane *5

Resolution: 1,024

(horizontal) × 1,024

(vertical)

Pressure-sensitive

1,000,000 touch operations.

Can be specified in CX-Designer. Font, style, and size can be specified.

Scalable Gothic: Magnification: 6 to 255 points

Rough: Magnification: 1 ×1, 1×2, 2×1, 2×2, 3×3, 4×4, 8×8

Standard: Magnification: 1 ×1, 1×2, 2×1, 2×2, 3×3, 4×4, 8×8

Fine: Magnification:

7-segment display:

1 ×1, 1×2, 2×1, 2×2, 3×3, 4×4, 8×8

Can display only numerals, dates, and times.

Scalable Gothic, rough, standard, and fine can be used for 42 languages.

Japanese, simplified Chinese, traditional Chinese, Korean, English, French, German, Italian, Portuguese, Spain, Swedish, Dutch,

Finnish, Norwegian, Basque, Catalan, Danish, Albanian, Croatian, Czech, Hungarian, Polish, Romanian, Slovak, Slovenian,

Bulgarian, Belarusian, Russian, Serbian, Macedonian, Ukrainian, Georgian, Icelandic, Afrikaans, Faroese, Indonesian, Greek,

Turkish, Estonian, Latvian, Lithuanian, Thai (supported only with scalable Gothic font)

256 colors

Text attributes

Font style

(only when vector font is specified)

Vertical alignment

Horizontal alignment

Bold or italic

Top, center, or bottom

Left-justified, centered, or right-justified

Flicker

Objects supporting flicker

Numeral units and scale settings

Alarm/event settings

Expansion interface

Functional objects: Select from up to 10 types of registered flicker settings. The flicker speed and flicker range can be set.

Fixed objects:

1.000 max.

5,000 max.

Select from three flicker types.

For Expansion Interface Units

*1. Contact your nearest OMRON representative to replace the backlight.

*2. This is the estimated time before brightness is reduced by half at room temperature and humidity. It is not a guaranteed value.

The service life will be dramatically shortened if PT is used at low temperatures. For example, using the PT at temperatures of 0 °C will reduce the service life to approximately 10,000 hours (reference value).

*3. Lot No. 28X1 or later of NS8 models, Lot No. 11Y1 or later of NS10 models, Lot No. 14Z1 or later of NS12 models, Lot No. 31114K or later of

NS15 models.

*4. This function does not indicate that the service life has been reached. It detects when the backlight is not lit due to a disconnection or other errors.

Backlight error detection indicates that all backlights (2) are OFF.

*5. An analog touch panel is used with the NS15. Do not press the touch panel in two or more places simultaneously.

If the touch panel is pressed in two or more places simultaneously, it may activate a switch between the points that are pressed.

13

14

NS

Series

Communications

NS5/NS8/NS10/NS12/NS15

Memory Card

Serial

Communications

USB

SLAVE

Specifications

USB HOST

Specifications *1

Port A

Port B

Interface

Functions

Connector

Functions

Connector

Functions

USB rating

Connector

Functions

USB rating

Connector

Functions

One ATA-Compact Flash interface slot

Used to transfer and store screen data, store logging data, and store history data. (Alarm/Event History, Operation

Log, and Error Log generated during Macro execution).

Conforms to EIA RS-232C. D-Sub female 9-pin connector 5-V output (250 mA max.) through pin 6.

The 5-V outputs of serial ports A and B cannot be used at the same time.

Host (PLC) access: 1:N NT Links (connections with CS/CJ/CP-series PLCs and C200HX/HG/HE(-Z) PLCs),

1:1 NT Links, or Host Link (connections with C Series or CVM1/CV-series PLCs)

Direct access to Temperature Controllers using Smart Active Parts:

CompoWay / F and bar code reader connections (Read directly from display.)

Conforms to EIA RS-232C. D-Sub female 9-pin connector. 5-V output (250 mA max.) through pin 6.

The 5-V outputs of serial ports A and B cannot be used at the same time.

Host (PLC) access: 1:N NT Links (connections with CS/CJ/CP-series PLCs and C200HX/HG/HE(-Z) PLCs) or

1:1 NT Links (connections with C Series or CVM1/CV-series PLCs)

Direct access to Temperature Controllers using Smart Active Parts:

CompoWay / F and bar code reader connections (Read directly from display.)

USB1.1

TYPE-B (Slave)

Connection with the CX-Designer (for screen data transfers) Connecting to a PictBridge-compatible Printer

Recommended printers: EPSON: PM-G4500, PX-G5300, PX-5600, EP-901F

Canon: PIXUS MX7600, PIXUS iP100, PIXUS iX5000

USB1.1

TYPE-A (Host)

Connection with a printer (for hard copies)

Recommended printers: EPSON: PX-G930

Built-in Ethernet

Specifications *2

Conformance standards

Conforms to IEEE 802.3/Ethernet (10 Base-T/100 Base-TX).

Functions

Baud rate

Host (PLC) access and connection with the CX-Designer (for screen data transfers)

2 M/1 M/500 K bps

Controller Link (Wiredtype)

Specifications *3

Transmission path

Shielded twisted-pair cable (special cable)

Functions

Resolution

Host (PLC) access and data links

NS-CA001: 320×240, 640×480, 800×600 dots

NS-CA002: User-defined size

NS-CA001: NTSC composite video or PAL

NS-CA002: NTSC composite video or PAL

Video Input Specifications

*4

Input signal

Number of video inputs

NS-CA001: Number of cameras: 4 max.

NS-CA002: 2 cameras + RGB

*1. Except NS5.

*2. NS@-@@@1-V2 only.

*3. Except NS5 and NS8.

*4. Except NS5 and NS15. NS15 provides RGB input. (NS-CA002)

NS

Series

Connectable Devices

Supported OMRON PLCs

RS-232C *1

PLC series PLC model name

C Series

CVM1/CV

Series

CS Series

CJ Series

CQM1

CQM1H

CPM1

CPM1A

CPM2A

CPM2C

C200HS

C200HE (-Z)

C200HG (Z)

C200HX (-Z)

CV500/1000/2000

CVM1

CS1H

CS1G

CS1D

CJ1H

CJ1G

CJ1M

CJ2H

No

No

No

No

Yes

Yes

Yes

Yes

Yes

1:1 NT Link

Yes

Yes

Yes

Yes

Yes

Yes

Yes

No

No

No

CP Series

CJ2M

CP1H

CP1L

CP1E

NJ5

No

No

No

No

Yes *5

Yes

Yes

Yes

Yes

Yes *5

NJ Series

NJ3 Yes *5 Yes *5

Note:

Including models whose production were discontinued.

Yes

Yes

Yes

Yes

Yes

Yes

Yes

No

No

1:N NT Link

No

Yes

No

No

No

No

No

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Host Link

Yes

Yes

Yes

No

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes *5

Yes *5

Yes

Yes

Yes

Yes

No

No

No

Yes

Yes

FINS *2

No

No

No

No

No

No

No

Yes

Yes

Yes

Yes

Yes

Yes

No

No

No

Ethernet

EtherNet/IP *3

No

No

No

No

No

No

No

Yes

Yes

Yes

Yes

No

No

No

No

No

Yes

Yes

Yes

Yes

Yes

No

No

Yes *6

Yes *6

Controller Link *4

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

No

Yes

No

No

No

No

No

Yes

Yes

Yes

Yes

No

No

No

No

No

*1. To connect a NS with a PLC via a RS-422A connection, OMRON's NS-AL002, or CJ1W-CIF11 RS-232C/RS-422A Converter can be used to convert the RS-232C port on the NS to RS-422A.

*2. A NS with Ethernet port is necessary.

When connecting a PLC with the NS, an Ethernet port is necessary on the PLC, too. Use a PLC CPU Unit with a built-in Ethernet port, or add an Ethernet Unit.

*3. A NS with Ethernet port is necessary.

When connecting a PLC with the NS, an EtherNet/IP port is necessary on the PLC, too. Use a PLC CPU Unit with a built-in EtherNet/IP port, or add an EtherNet/IP Unit.

*4. Install a Controller Link Interface Unit on the NS. A Controller Link Unit is necessary for the PLC.

*5. Mount a Serial Communications Unit on the NJ-series Controller. A NS can access only to the Controller's memory used for CJ-series unit.

*6. When using a EtherNet/IP Unit to connect the NJ-series Controller, NJ Troubleshooter is not supported.

15

16

NS

Series

Function Comparison

PLC series PLC model name

Ladder

Monitor

Device Monitor/

Switch Box

PLC Data

Trace

SPMA SAP

EtherNet/IP

Tag access

(Network symbols)

C series

CVM1/CV series

CS series

CJ series

CP series

NJ series

CS1D

CJ1H

CJ1G

CJ1M

CJ2H

CJ2M

CP1H

CP1L

CP1E

NJ5

NJ3

CQM1

CQM1H

CPM1

CPM1A

CPM2A

CPM2C

C200HS

C200HE (-Z)

C200HG (-Z)

C200HX (-Z)

CV500/1000/2000

CVM1

CS1H

CS1G

Note:

Including models whose production were discontinued.

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

No

No

No

No

No

Yes

Yes

No

No

No

No

No

No

No

No

No

No

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

No

Yes *2

Yes *2

No

No

Yes

Yes

No

No

No

No

No

No

No

No

No

No

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes *3

Yes *3

No

No

Yes

Yes

No

No

No

No

No

No

No

No

No

No

Yes

Yes

Yes

Yes

Yes

Yes

Yes *1

Yes *1

Yes *1

No

No

No

No

Yes

Yes

No

No

No

No

No

No

No

No

No

No

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

No

No

No

No

No

Yes

Yes

No

No

No

No

No

No

No

No

No

No

*1. The SPMA relaying a PLC is not supported.

*2. Only Device Monitor function is supported. Monitoring function that uses tags (variables) is not supported.

*3. The SAP for CJ-series Special I/O Units and CPU Bus Units that can be used with NJ-series Controller is supported.

*4. Sysmac Studio version 1.02 or higher (CX-Designer version 3.41 or higher) is required.

Yes

Yes

No

No

No

No

No

No

No

Yes

Yes

No

No

No

No

No

No

No

No

No

No

No

No

No

No

Yes

Yes

No

No

Yes

Yes

Yes

Yes

No

No

No

PLC

Troubleshooter

NJ

Troubleshooter/

Integrated

NS-series PT simulation *4

No

No

No

No

No

No

No

No

No

No

No

No

No

No

Yes

Yes

No

No

No

No

No

No

No

No

No

No

No

No

No

No

No

No

No

No

No

No

No

Yes

Yes

NS

Series

Connectable Inverters

Series

3G3MX2

3G3JX

3G3RX

Communication Unit

(Use the RS-485 terminal on the Inverter)

(Use the RS-485 connector on the Inverter)

(Use the RS-485 terminal on the Inverter)

RS-485 (2-wire)

Connectable Temperature Controllers

The following Temperature Controllers can be connected directly to an NS-series PT*.

Unit name

Modular Temperature Controller EJ1

Series

EJ1-EDU End Unit

Model

Modular Temperature Controller

Digital Controller

E5ZN

E5AR

E5ER

E5ZN-SCT24S Terminal Unit

E5AR-

@@@@@@@@@-FLK

E5ER@@@@@@@@@-FLK

E5CN-

@@@@@T-FLK Multi-input

(Thermocouple/Resistance Thermometer) Type

E5CN-

@@@@@L-FLK Analog Input Type

E5EN-

@@@@@T-FLK Multi-input

(Thermocouple/Resistance Thermometer) Type

Temperature Controller

(Digital Controller)

E5AN/E5EN/E5CN

(Basic Model)

E5AN-H/E5EN-H/

E5CN-H

(Advanced Model)

E5GN

E5EN@@@@@L-FLK Analog Input Type

E5AN-

@@@@@T-FLK Multi-input

(Thermocouple/Resistance Thermometer) Type

E5AN-

@@@@@L-FLK Analog Input Type

E5CN-H

@@@@@@@-FLK Universal-input Model

E5EN-H @@@@@@@@-FLK Universal-input Model

E5AN-H

@@@@@@@@-FLK Universal-input Model

E5GN-

@@@TC-FLK Thermocouple Input Type

E5GN-

@@@P-FLK Resistance Thermometer Input Type

* The NS-Runtime cannot be connected directly to a Temperature Controller.

Connection

Remarks

SAP screens are available.

1:N

17

18

NS

Series

Connecting to Another Company’s PLC

Manufacturer Series CPU Communication Unit/Adapter/Board Connection diagram

A Series

FX Series

A1SHCPU

A2USCPU

A2USHCPU-S1

A2ACPU

FX0N

FX1S

FX1N

FX1NC

FX2N

FX3UC

FX3G

Q00CPU

Q01CPU

Computer Link Unit

A1SJ71UC24-R

@

A1SJ71UC24-PRF

Computer Link Unit

AJ71UC24

Communication special adapter

FX3U-232-ADP

FX2NC-232ADP

FX0N-232-ADP

Communication expansion board

FX

@@-232-BD

RS-232C port on the CPU Module

RS-232C,

RS422A/485 *1

RS-232C,

RS422A/485 *1

RS-232C

Mitsubishi Electric

Q/QnA Series

Q00CPU

Q01CPU

Q00JCPU

Q02CPU

Q02HCPU

Q06HCPU

Q12HCPU

Q25HCPU

Q03UDCPU

Q06UDHCPU

Q13UDHCPU

Q2ASCPU

Q2ASCPU-S1

Q2ASHCPU

Q2ASHCPU-S1

Serial Communications Module

QJ71C24N-R2

QJ71C24N-R4

QJ71C24N

Serial Communications Module

A1SJ71QC24N

RS-232C,

RS-485 (4-wire) *2

Yokogawa

Electric

FA-M3(R) Series

F3SC23-1F

F3SP21-0N

F3SP28-3S

F3SP58-6S

F3SP67-6S

CPU built-in RS-232C port

Personal Computer Link Module

F3LC11-1F

F3LC12-1F

F3LC11-2F

RS-232C

RS-232C, RS-422A/485 *1

Siemens S7-300 Series

SLC500

CPU313

CPU315-2DP

CPU317-2PN/DP

SLC5/03

SLC5/04

SLC5/05

MicroLogix 1500

SIMATIC S7 HMI Adapter

6ES7 972-0CA1

@-0XA0

RS-232C port on the CPU Module

RS-232C

RS-232C

Rockwell

(Allen-Bradley)

MicroLogix

ControlLogix

CompactLogix

PLC-5

Logix5555

1769-L31

PLC-5/20

RS-232C port on the CPU Module

RS-232C port on the CPU Module

RS-232C port on the CPU Module

RS-232C port or RS-485 port on the

CPU Module

RS-232C

RS-232C

RS-232C

RS-232C/RS-485 (4-wire)

*1. To connect using RS-422A/485, an RS-232C/422A converter (e.g. NS-AL002, CJ1W-CIF11) is required.

*2. To connect using RS-485, an RS-232C/422A converter (e.g. NS-AL002, CJ1W-CIF11) is required.

Up to 32 sequencers can be connected when using RS-485.

1:1

1:N

1:1

1:1

1:1

1:1

1:1

1:1

1:N

1:1

1:1

Component Names and Options

NS15

RS-422A/485 Serial Interface

Memory Card interface

Memory Card

Note:

Colors shown in photographs and product names may differ from actual colors and names.

Expansion interface

Battery

Analog RGB Output

RS-232C serial port A

RS-232C serial port B

A bar code reader can be connected to the serial port.

Recommended bar code reader: V520-RH21-6

Connector for

Brightness Adjustment

Power Supply (24 VDC)

Ethernet (10 Base-T or 100 Base-TX)

USB SLAVE (For transferring screens and connecting a PictBridge-compatible printer)

USB HOST (for printer)

NS12/10

Memory Card interface

Power Supply (24 VDC)

Memory Card

Note:

Colors shown in photographs and product names may differ from actual colors and names.

Expansion interface

Battery

RS-232C serial port A

RS-232C serial port B

A bar code reader can be connected to the serial port.

Recommended bar code reader: V520-RH21-6

Ethernet (10 Base-T or 100 Base-TX)

USB SLAVE (For transferring screens and connecting a PictBridge-compatible printer)

USB HOST (for printer)

NS8

Memory Card interface

NS

Series

Power Supply

(24 VDC)

Expansion interface

Memory Card

Note:

Colors shown in photographs and product names may differ from actual colors and names.

Battery

RS-232C serial port A

RS-232C serial port B

A bar code reader can be connected to the serial port.

Recommended bar code reader: V520-RH21-6

Ethernet (10 Base-T or 100 Base-TX)

USB SLAVE (For transferring screens and connecting a PictBridge-compatible printer)

USB HOST (for printer)

19

NS

Series

NS5

Battery

Power Supply (24 VDC)

NSH5

USB Port Memory Card interface

Enable Switch

LED

Emergency Stop Switch

Memory Card interface

Memory Card

Note:

Colors shown in photographs and product names may differ from actual colors and names.

Expansion interface

Ethernet (10 Base-T or 100 Base-TX)

USB SLAVE (For transferring screens and connecting a PictBridge-compatible printer)

RS-232C serial port A

RS-232C serial port B

A bar code reader can be connected to the serial port.

Recommended bar code reader: V520-RH21-6

Hand Strap

Optional Products

Cable

Function Switches

Video Input Unit

NS-CA001 (with Cover)

RGB/Video Input Unit

NS-CA002 (with Cover)

Controller Link Interface Unit

NS-CLK21 (with Cover)

RS-422A Adapter

CJ1W-CIF11

RS-232C/RS-422A

Conversion Unit

NS-AL002

20

Communications Cable

XW2Z-S002

Protective Cover/Anti-reflection

Sheet for NS-series PT

NS-KBA0 (N)

NT30/NT31C-KBA05 (N)

USB Serial Conversion Cable

CS1W-CIF31

USB relay cable

(IP65 oil-proof type)

NS-USBEXT-1M

Dimensions

NS15

NS

Series

(Units: mm)

Mounting Panel

Mounting Bracket 13.95

79.54

94.8

170

RUN

304

282

304.5

27.4

71.8 57.31

RDA

RDB

SDA

SDB

RSA

RSB

46

3.8

85.6

86.83

405

8

70

75.8

37.9 (min.)

41.1 (max.)

39.4

84.1

Recommended Panel Cutout Dimensions

340

383

405.5

15.5

282.5

+1

−0

NS12/10

264

315

323

15.5

140 241

227 249

7.5

48.5

49

39 (min.)

42 (max.)

383.5

+1

−0

24V

DC

HOST SLAVE

ETHERNET

PORT B PORT A

SW

RESET

121

134

3.8

23

13.7

49.9

90.4

Recommended Panel Cutout

Dimensions

228

+1

−0

302

+1

−0

301

NS8

177 165 188

180

232

15.5

5

48.5

39 (min.)

42 (max.)

49

220

120.5

24V

DC

HOST

ETHERNET

PORT B PORT A

SW

RESET

19.1

107.6

9.6

26.6

44.1 50.1

63.4

Recommended Panel

Cutout Dimensions

165.5

+0.5

−0

220.5

+0.5

−0

NS5

39.83

27.3

44.55

142

RUN

90

195

15.5

145

206.3

130.5

153.3

5

53.8

54.8

34 (min.)

38 (max.)

183.5

19.5

21

51.7

77

ETHERNET

68.48

Recommended Panel

Cutout Dimensions

131

+0.5

−0

184

+0.5

−0

21

22

NS

Series

Hand-held NS5

223

176

16.5

70.5

50

75

75

NS-CA001

Video Input Unit

9.6

(1.9)

(22.3)

10.6

81.3

(102.7)

5

21.4

164

(169)

127.3

50.3

68.3

86.3

104.3

9.7

20.4

11

NS-CA002

Video Input Unit

9.6

(1.9)

(22.3)

11.1

81.3

(102.7)

5

21.4

164

(169)

39.3

57.3

82.8

118.3

9.7

20.4

11

NS-CLK21

Controller Link Interface Unit

151.5

(183)

(1.9)

(33.9)

164

(169)

95.6

31.5

5

10.8

32

11

Related Manuals

Cat. No.

V083

V073

V099

V082

V086

V090

V098

V085

V092

V075

V093

Model

NS15/NS12/NS10/NS8/NS5

NS15/NS12/NS10/NS8/NS5

NS-CXDC1-V3

NS

NS-CA002

NSH5

NS15/NS12/NS10/NS8/NS5

NS15/NS12/NS10/NS8/NS5

NS15/NS12/NS10/NS8/NS5

NS15/NS12/NS10/NS8/NS5

NS-NSRCL

@@

Manual

NS-Series Programmable Terminals SETUP MANUAL

NS-Series Programmable Terminals PROGRAMMING MANUAL

CX-Designer Ver.3.

@ USER'S MANUAL

NS-Series Ladder Monitor OPERATION MANUAL (Ladder Monitor I/O Comment Extracting Tool)

NS-Series RGB and Video Input Unit OPERATION MANUAL

NSH5-Series Hand-held Programmable Terminal OPERATION MANUAL

NS-Series Programmable Terminals HOST CONNECTION MANUAL (Host Link) OPERATION MANUAL

NS-Series Programmable Terminals HOST CONNECTION MANUAL

NS-Series Programmable Terminals HOST CONNECTION MANUAL Multivendor Connection

NS-Series Programmable Terminals Macro Reference

NS-NSRCL

@@ NS-Runtime Software USERS MANUAL

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement