- No category
advertisement
Programmable Terminals
NS Series
Even Simpler Equipment Operation with Outstanding Synergy.
5.7
inches
Color TFT
STN monochrome
10.4
inches
Color TFT
15
inches
Color TFT
12.1
inches
Color TFT
8.4
inches
Color TFT
Features
• 5.7 to 12.1 inch sizes are available.
• A hand-held version of the NS5 is now available to perform operations at the production site. The NS-series PT's have a complete set of functions that can be used at the production site.
• The Smart Active Parts(SAP Library) makes it easy to connect to OMRON PLCs and components,
OMRON provides a development environment that requires with no programming and no screen designing.
• When an error occurs in a Unit in the OMRON PLCs, the Troubleshooter SAP Library provides an easy-tounderstand explanation of the cause of the error as well as the countermeasures.
• Ladder Monitor come as a Standard Feature. The ladder program can be monitored onsite without a laptop!
Ladder monitor lets you monitor PLC program status, search for addresses or instructions, monitor multiple I/O points, and much more.
• Provides the FA integrated tool package "CX-One" for a Screen Design Software Integrated Simulation come as a
Standard Feature. The integrated simulation function simulates ladder programs and screen data simultaneously even without the actual hardware.
• Screens support 42 languages and the Support Software supports eight. System messages can be displayed in eight languages.
• Single Port Multi Access (SPMA) come as a Standard Feature. The ladder program and screen data can be transferred from a single port!
• Connectable PLCs and devices appear one after another.
Has become connectable with the PLCs of Mitsubishi Electric Corporation and the Inverters of OMRON
Corporation.
Sysmac is a trademark or registered trademark of OMRON Corporation in Japan and other countries for OMRON factory automation products.
Windows is registered trademarks of Microsoft Corporation in the USA and other countries.
EtherCAT is a registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany.
Other company names and product names in this document are the trademarks or registered trademarks of their respective companies.
1
2
NS
Series
Network
Provides serial NT Link communications supporting both 1:1 and 1:N connections. The NT Link has more efficient communications than Host Link and its capabilities are especially apparent in applications with multiple PTs connect to the PLC. The NS-series PTs can also support communications with multiple PLCs and multiple NS-series PTs through Controller Link and Ethernet connections, so the network can be configured freely to match the requirements and scale of the application. In addition, using the NS-Runtime makes it possible to monitor machine status and log data from the host.
[Example NS-series Network
Configuration]
1
EtherNet/IP (Tag access)
4
EtherNet/IP, Ethernet
CS/CJ-series
PLC
Personal computer
Software for Machine Monitoring and
Data Logging
(sold separately)
NS-series PT
2
Serial connection
3
Controller Link
5
Connections across network levels
CS/CJ-series
PLC
CS/CJ-series
PLC
NS-series PT
2
Serial connection
CS/CJ-series PLC
NS-series PT
NS-series PT
Configuration of CJ2 series and NJ series
1 EtherNet/IP Connection (Tag accesses)
If an Ethernet-compatible NS-series PT is used, the PT can connect to a Controller with built-in EtherNet/IP and an Option Unit is not needed to connect at the PT.
NS-series PT
Personal computer
NS-series PT
Controller Controller Controller
NS
Series
Configuration of CS series, CJ series and CP series
2 Serial connection
1:1 NT Link or Host Link
NS:PLC = 1:1
Connecting with the PLC through port A or port B
NS-series PT
PLC
NS:PLC = 1:2
PLC
NS-series PT
PLC
1:N NT Link
NS:PLC ratio = 8:1 max.
Up to 8 NS-series PTs can be connected to each of the PLC's RS-232C/RS-422A ports.
NS-series
PT
NS-series
PT
NS-series
PT
PLC
NS-AL002 Converter
(Converts between
RS-232C and RS-422A.)
3 Controller Link Connection
The PT can be connected to an OMRON Controller Link network by mounting a Controller Link Interface Unit.
NS-CLK21
NS Series
PT
PLC PLC PLC
If a Controller Link connection is used, data links can be set between PLCs and multiple
PLCs can be monitored/set from the NS-series PT's screen.
Baud rate
2 Mbps (500 m max.)
1 Mbps (800 m max.)
500 kbps (1 km max.)
Max. number of nodes: 32 nodes
4 EtherNet/IP or Ethernet Connection
If an Ethernet-compatible NS-series PT is used, the PT can connect to a PLC with an Ethernet Unit and an Option Unit is not needed to connect at the PT.
NS Series PT
Personal computer
NS Series PT
PLC PLC PLC
5 Connections Over Network Levels
The NS-series PTs can connect to a variety of devices in the network, through as many as 3 network levels.
For example, if SAP (Smart Active Parts) are being used, an NS-series PT connected by Ethernet can be used to monitor the information in a PLC connected through Controller Link as well as the information in the DeviceNet Slaves connected to that PLC.
NS Series
PT
NS Series
PT
Ethernet
PLC
Seamless and
Program-less
Seamless and
Program-less
Controller Link
PLC PLC
DeviceNet
3
4
NS
Series
System Configuration
NS5/NS8/NS10/NS12/NS15
Memory Card
Interface
OMRON
Memory Card
Ethernet port
USB
Slave
USB
Master
RS-232C port
RS-232C port
RS-422A Conversion Unit
CJ1W-CIF11
NS-AL002
Note:
A Conversion Unit is not required to connect to the RS-422A/485 serial interface of the NS15.
OMRON PLC
PT-to-PLC Connecting Cable
XW2Z-200T (Length: 2 m)
XW2Z-500T (Length: 5 m)
RS-232C
Bar Code Reader
Recommended: OMRON
V520-RH21-6
RS-232C
Screen transfer cable
XW2Z-S002 (Length: 2 m)
Screen transfer cable
XW2Z-S002 (Length: 2 m)
USB Serial Conversion Cable
CS1W-CIF31
USB
Personal computer
Memory link connection
Micro-computer board, personal computer, etc.
CompoWay/F connection
Temperature
Controller
Modbus (MEMOBUS)-RTU connection
RS-422A
OMRON
PLC
Inverter
Standard USB cable
Commercially available.
Standard USB cable
Commercially available.
Standard USB cable
Commercially available.
PictBridge
USB
USB
PictBridge-compatible printer
WE70
Wireless
WE70
Ethernet
Ethernet
EtherNet/IP
OMRON
PLC
OMRON
PLC
OMRON
Controller
Personal computer
Ethernet
Personal computer
NS
Series
Expansion Bus Interface
Any one of the following Units can be mounted to the expansion bus interface.
Controller Link Interface Unit
NS-CLK21
Controller Link
Video Input Unit
NS-CA001
NTSC/PAL
RGB/Video Input Unit
NS-CA002
NTSC/PAL
RGB output
Expansion bus interface
Note:
Video Input Units and RGB Video Input Units cannot be used with some models.
Multi-vendor
PLC
Vision
Sensor
Personal computer
RS-232C port
RS-232C port
RS-232C
Computer Link Unit
Mitsubishi A-series PLC
Function Extension Board or Mitsubishi
FX-series PLC Communications Adapter
Mitsubishi FX-series PLC
Serial Communications Unit
Mitsubishi QnA-series PLC
Serial Communications Unit
Mitsubishi Q-series PLC
Computer Link Module
Yokogawa’s FA-M3(R) Series
SIMATIC S7 HMI Adapter
Siemens S7-300-series PLC
Serial Communications Module
Yaskawa MP-series PLC
RS-422A
Conversion Unit
CJ1W-CIF11
NS-AL002
Note:
A Conversion Unit is not required to connect to the
RS-422A/485 serial interface of the NS15.
RS-422A/485 (See note.)
Screen transfer cable
XW2Z-S002 (Length: 2 m)
Rockwell (Allen-Bradley)
SLC500/Micrologix/ControlLogix/
CompactLogix/PLC-5-series PLC
Modbus device (RTU mode)
Computer Link Unit
Mitsubishi A-series PLC
Function Extension Board or Mitsubishi
FX-series PLC Communications Adapter
Mitsubishi FX-series PLC
Serial Communications Unit
Mitsubishi QnA-series PLC
Serial Communications Unit
Mitsubishi Q-series PLC
Computer Link Module
Yokogawa’s FA-M3(R) Series
Serial Communications Module
Yaskawa MP-series PLC
Rockwell (Allen-Bradley)
PLC-5-series PLC
Modbus device (RTU mode)
Note:
Whether an RS-422A or RS-485 connection is supported depends on the device that you are connecting to.
For details, refer to the Connectable Devices page or NS-Series Programmable Terminals HOST CONNECTION MANUAL Multivendor
Connection (Cat.V092).
5
6
NS
Series
NSH5 Hand-held PT
USB
Commercially available USB cable.
USB Slave
Memory
Card interface
NSH5 PT
UL-listed Cables
OMRON
Memory Card
RS-232C cable
RS-422A cable
RS-232C Connecting Cable for the NSH5
NSH5-232CW-3M (Length: 3 m)
RS-232C Connecting Cable for the NSH5
NSH5-232CW-10M (Length: 10 m)
RS-422A Connecting Cable for the NSH5
NSH5-422CW-10M (Length: 10 m)
RS-232C
RS-422A
RS-232C cable
RS-422A cable
RS-232C Connecting Cable for the NSH5
NSH5-232UL-3M (Length: 3 m)
RS-232C Connecting Cable for the NSH5
NSH5-232UL-10M (Length: 10 m)
RS-422A Connecting Cable for the NSH5
NSH5-422UL-10M (Length: 10 m)
RS-232C
RS-422A
Personal computer
PLC
PLC
PLC
PLC
USB
USB Slave
Memory
Card interface
NSH5 PT
Commercially available USB cable.
OMRON
Memory Card
Personal computer
Removable Box Connected
RS-232C cable
RS-232C Connecting Cable for the NSH5
NSH5-232CN-3M (Length: 3 m)
RS-232C Connecting Cable for the NSH5
NSH5-232CN-10M (Length: 10 m)
Removable Box
RS-422A
PLC
System Configuration
(Removable Box Connected)
Up to eight NSH5s can be connected at a time.
NSH5 (See note.)
PLC
Removable
Box
Control panel
RS-422A connection (Total cable length: 500 m max.)
RS-232C connection
(Cable length: 3 or 10 m)
Up to 15 Removable Boxes can be connected.
Note:
Before removing the NSH5 from the Removable Box, be sure to first turn OFF the power supply key on the Removable Box.
NS
Series
Ordering Information
International Standards
• The standards are availabled as follows: U: UL, U1: UL (Class I Division 2 Products for Hazardous Locations), C: CSA, UC: cULus, UC1: cULus
(Class I Division 2 Products for Hazardous Locations), CU: cUL, N: NK, L: Lloyd, and CE: EC Directives.
• Contact your OMRON representative for further details and applicable conditions for these standards.
Programmable Terminals
Product name
NS5-V2 *1
NS8-V2
NS10-V2
NS12-V2
Effective display area
5.7-inch *2
TFT color
LED backlight
5.7-inch *2
High-luminance
TFT color
LED backlight
8.4-inch *2
TFT
LED backlight
10.4-inch *2
TFT
LED backlight
12.1-inch *2
TFT
LED backlight
Specifications
Number of dots
320 × 240 dots
640 × 480 dots
640 × 480 dots
800 × 600 dots
Ethernet
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
Case color
Ivory
Black
Ivory
Black
Ivory
Black
Ivory
Black
Ivory
Black
Ivory
Black
Ivory
Black
Ivory
Black
Ivory
Black
Ivory
Black
Model
NS5-SQ10-V2
NS5-SQ10B-V2
NS5-SQ11-V2
NS5-SQ11B-V2
NS5-TQ10-V2
NS5-TQ10B-V2
NS5-TQ11-V2
NS5-TQ11B-V2
NS8-TV00-V2
NS8-TV00B-V2
NS8-TV01-V2
NS8-TV01B-V2
NS10-TV00-V2
NS10-TV00B-V2
NS10-TV01-V2
NS10-TV01B-V2
NS12-TS00-V2
NS12-TS00B-V2
NS12-TS01-V2
Standards
UC1, CE,
N, L,
UL Type4
UC1, CE,
N, L
UC1, CE,
N, L,
UL Type4
NS12-TS01B-V2
NS15-V2
15-inch
TFT
1,024 × 768 dots Yes
Silver
NS15-TX01S-V2
Black
NS15-TX01B-V2
NSH5-V2 *1
Hand-held
5.7-inch
TFT
320
× 240 dots
No
Black (Emergency stop button: Red)
Black
(Stop button: Gray)
NSH5-SQR10B-V2
NSH5-SQG10B-V2
UC, CE
*1. As of July 2008, the image memory has been increased to 60 MB.
*2. Lot No. 15Z0 or later of NS5 color-type models, Lot No. 28X1 or later of NS8 models, Lot No. 11Y1 or later of NS10 models, Lot No. 14Z1 or later of NS12 models, LotNo.31114K or later of NS15 models.
NS-Runtime
Product name
NS-Runtime
Specifications
NS-Runtime Installer, PDF manual, hardware key (See note.)
1license
3 licenses
10 licenses
Media
CD
Model
NS-NSRCL1
NS-NSRCL3
NS-NSRCL10
Note:
A hardware key (USB dongle) is required for NS-Runtime operation.
●System Requirements
Item
OS
CPU
Memory size
Specifications
Windows XP (Service Pack 3 or higher), Vista, 7 or 8 (Support 64-bit version for Windows 7 and Windows 8.)
Celeron, 1.3 GHz or higher (Recommended)
HDD: 50 MB min., RAM: 512 MB min. (Windows 7: 1 GB min.).
50 MB is required for the Runtime alone. (An additional 280 MB is required if CX-Server is not already installed.)
Standards
---
7
8
NS
Series
Software
●How to Select Required Support Software for Your Controller
The required Support Software depends on the Controller to connect. Please check the following table when purchasing the Support Software.
Item
Controller
Programmable Terminals
Software
Omron PLC System
CS, CJ, CP, and other series
NS-series
FA Integrated Tool Package CX-One
Omron Machine Automation Controller System
NJ-series
NS-series with an Ethernet port
Automation Software Sysmac Studio
●FA Integrated Tool Package CX-One
Product name
Specifications Number of licenses
Media
Model Standards
FA Integrated
Tool Package
CX-One Ver.4.
@
The CX-One is a comprehensive software package that integrates Support
Software for OMRON PLCs and components.
CX-One runs on the following OS.
Windows XP (Service Pack 3 or higher, 32-bit version) / Windows Vista (32-bit/
64-bit version) / Windows 7 (32-bit/64-bit version) / Windows 8 (32-bit/64-bit version) / Windows 8.1 (32-bit/64-bit version)
CX-One Version 4.
@ includes CX-Designer Ver.3.@.
For details, refer to the CX-One catalog (Cat. No. R134)
*1. Multi licenses are available for the CX-One (3, 10, 30, or 50 licenses).
*2. The CX-One is also available on CD (CXONE-AL@@C-V4).
license
*1
DVD
*2
CXONE-AL01D-V4
●Automation Software Sysmac Studio
Please purchase a DVD and required number of licenses the first time you purchase the Sysmac Studio. DVDs and licenses are available individually. Each model of licenses does not include any DVD.
---
Specifications
Product name
Number of licenses
Media
Model Standards
Sysmac Studio
Standard Edition
Ver.1.
@
The Sysmac Studio provides an integrated development environment to set up, program, debug, and maintain NJ-series Controllers and other Machine
Automation Controllers, as well as EtherCAT slaves.
Sysmac Studio runs on the following OS.
Windows XP (Service Pack 3 or higher, 32-bit version) / Windows Vista (32-bit version) / Windows 7 (32-bit/64-bit version) / Windows 8 (32-bit/64-bit version) /
Windows 8.1 (32-bit/64-bit version)
The Sysmac Studio Standard Edition DVD includes Support Software to set up
EtherNet/IP Units, DeviceNet slaves, Serial Communications Units, and
Support Software for creating screens on HMIs (CX-Designer).
For details, refer to the Sysmac Integrated Catalogue (P072).
- (Media only) DVD
1 license* ---
SYSMAC-SE200D
SYSMAC-SE201L
Note: 1.
To connect the NJ5 Controller, NS system version 8.5 or higher is required. CX-Designer version 3.3 or higher is also required.
2.
To connect the NJ3 Controller, NS system version 8.61 or higher is required. CX-Designer version 3.4 or higher is also required.
* Multi licenses are available for the Sysmac Studio (3, 10, 30, or 50 licenses).
---
---
NS
Series
Cable
Product name
Cable *1
Specifications
Screen transfer cable for DOS/V (CX-Designer ↔ PT)
USB-Serial Conversion Cable
Length: 2 m
Length: 0.5 m
Model
XW2Z-S002
Standards
---
N
CS1W-CIF31
USB relay cable Length: 1 m
NS-USBEXT-1M
NSH5 Cables
UL-compliant
NSH5 Cable
PT-to-PLC
Connecting Cable *2
NSH5 Removable Box
Cable
RS-422A cable (loose wires + D-Sub 9-pin)
RS-232C cable (loose wires + D-Sub 9-pin)
RS-232C cable (loose wires + D-Sub 9-pin)
RS-422A cable (loose wires)
RS-232C cable (loose wires + relay cable)
RS-232C cable (loose wires + relay cable)
PT connection: 9 pins
PLC connection: 9 pins
PT connection: 9 pins
PLC peripheral port
RS-232C Cable (connectors)
Length: 10 m
Length: 3 m
Length: 10 m
Length: 10 m
Length: 3 m
Length: 10 m
Length: 2 m
Length: 5 m
Length: 2 m
Length: 5 m
Length: 3 m
Length: 10 m
NSH5-422CW-10M
NSH5-232CW-3M
NSH5-232CW-10M
NSH5-422UL-10M
NSH5-232UL-3M
NSH5-232UL-10M
XW2Z-200T
XW2Z-500T
XW2Z-200T-2
XW2Z-500T-2
NSH5-232CN-3M
NSH5-232CN-10M
NSH5-AL001
CU
NSH5 Removable Box
---
NSH5 Wall-mounting
Bracket
---
NSH5-ATT02
NSH5 Visor
---
NSH5-ATT01
*1. Use a standard USB Type A male to Type B type male Cable to connect the NS series PT to a personal computer (CX-Designer).
Use a standard USB cable to connect the NS series PT to a PictBridge-compatible printer. USB cable type depends on the printer.
*2. To connect the NS series PT to NJ series Controller, using a commercially available 10/100-BASE-TX twisted-pair cable.
For detail, refer to the NS series SETUP MANUAL (Cat. No.V083).
---
---
9
10
NS
Series
Options
Product name
Video
Input
Unit
Inputs: 4 channels
Signal type: NTSC/PAL
Specifications
Input channels: 2 video channels and 1 RGB channel *1
Signal type: NTSC/PAL
Special Cable for the
Console
Controller Link Interface
Unit
Cable length: 2 m
Cable length: 5 m
For Controller Link Communications
RS-422A
Adapter
Sheet/Cover *2
Transmission distance: 500 m total length
Note:
Use this model when connecting PT models without a V
Note:
PT models with the V
@ suffix can also be connected.
@ suffix.
Transmission distance: 50 m total length
Note:
Only PT models with a suffix of V
@ are connectable.
Use the NS-AL002 to connect models without a V
@ suffix.
Anti-reflection Sheets
(5 surface sheets)
Protective Covers (5 pack)
(anti-reflection coating)
Protective Covers
(1 cover included)
(Transparent)
Protective Covers
(5 covers included)
(Transparent)
Attachment
Memory
Card
NT625C/631/631C Series to NS12/10 Series
NT625C/631/631C Series to NS12/NS10 Series (Black)
NT610C Series to NS12/10 Series
NT620S/620C/600S Series to NS8 Series
NT600M/600G/610G/612G Series to NS8 Series
128 MB
256 MB
512 MB
---
Memory Card Adapter
Replacement Battery
Bar Code Reader
Battery life: 5 years (at 25°C)
CCD handheld bar code reader (RS-232C interface)
*1. One screen cannot display two video inputs simultaneously.
*2. A Chemical-resistant Cover (NT30-KBA01) is available only for the NS5.
NS15
NS12/10
NS8
NS5
NS12/10
NS8
NS5
NS15
NS12/10
NS8
NS5
Model
NS-CA001
NS-CA002
F150-VKP (2 m)
F150-VKP (5 m)
NS-CLK21
NS-AL002
CJ1W-CIF11
NS15-KBA04
NS12-KBA04
NS7-KBA04
NT30-KBA04
NS12-KBA05
NS7-KBA05
NT31C-KBA05
NS15-KBA05N
NS12-KBA05N
NS7-KBA05N
NT31C-KBA05N
NS12-ATT01
NS12-ATT01B
NS12-ATT02
NS8-ATT01
NS8-ATT02
HMC-EF183
HMC-EF283
HMC-EF583
HMC-AP001
CJ1W-BAT01
V520-RH21-6
---
CE
---
Standards
UC1, CE
---
UC1, CE
---
UC1, N,
L, CE
NS
Series
General Specifications
NS5/NS8/NS10/NS12/NS15
Series NS5-V2 NS8-V2 NS10-V2 NS12-V2
Rated power supply voltage
24 VDC
Allowable voltage range
20.4 to 27.6 VDC (24 VDC ±15%)
Power consumption
15 W max.
25 W max.
Ambient operating temperature
Storage temperature
0 to 50 °C (See note on the next page.)
Note:
The ambient operating temperature is subject to the following restrictions according to the mounting angle.
Mounting angle of 0 to 30 ° to the horizontal:
• When no Expansion Units are mounted, the operating temperature range is 0 to 45
°C.
• When a Video Input Unit or a Controller Link Interface Unit is mounted, the ambient operating temperature is 0 to 35
°C.
Mounting angle of 30 to 90
° to the horizontal: Operating temperature range of 0 to 50°C
−20 to 60 °C *1
Ambient operating humidity
35 to 85% (0 to 40
°C), 35 to 60% (40 to 50 °C) (with no condensation)
Operating environment
Noise immunity
No corrosive gases.
Conforms to IEC61000-4-4, 2 kV (power lines).
90°
Displa y s urf ace
NS15-V2
45 W max.
30°
Horizontal 0°
Vibration resistance
(during operation)
10 to 57 Hz, 0.075 mm amplitude, 57 to 150 Hz, 9.8 m/s
2
30 min each in X, Y, and Z directions
5 to 8.4 Hz, 3.5 mm single amplitude, 8.4 to 150 Hz,
9.8 m/s
2
10 min times each in X, Y, and Z directions
Shock resistance
(during operation)
Weight
147 m/s 2 3 times each in direction of X, Y, and Z
Degree of protection
Ground
Battery life
Applicable standards
1.0 kg max.
2.0 kg max.
2.3 kg max.
2.5 kg max.
Front operating panel: IP65 oil-proof type and NEMA4 UL type 4. *2
Note:
May not be applicable in locations with long-term exposure to oil.
Ground to 100 Ω or less.
5 years (at 25 °C): Replace battery within 5 days after the battery runs low (indicator lights orange).
Certified for conformance to UL 508, UL 1604, EMC Directive, NK, and LR Standards.
*1. Operate the PT within the temperature and humidity ranges shown in the right diagram.
*2. Support for NS5, NS10, NS12 and NS15.
Operation
4.2 kg max.
Storage
60
Humidity (%RH)
95%
8
0%
60%
Temperature (°C)
−20
0
0
10
20
30
40
50
10 20 30 40 50
Temperature (°C)
60 70
40%
35%
20%
8
0
10%
NSH5 Hand-held PT
Series NSH5-V2
Type
Case color
Built-in Ethernet port
5.7-inch Color TFT (Hand-held Version)
Black
No
NSH5-SQR10B-V2 (Emergency stop button: Red) NSH5-SQG10B-V2 (Stop button: Gray)
Model
Rated power supply voltage
24 VDC
Allowable voltage range
20.4 to 27.6 VDC (24 VDC ±15%)
Power consumption
10 W max.
Ambient operating temperature
0 to 40 °C
Storage temperature
Noise immunity
−20 to 60°C
Ambient operating humidity
35% to 85% (0 to 40
Operating environment
No corrosive gases.
°C) with no condensation
Common mode: 1,000 Vp-p (between power supply terminals and panel)
Normal mode: 300 Vp-p
Pulse width: 100 ns to 1 μs, Rise time: 1-ns pulse
Vibration resistance
(during operation)
10 to 57 Hz, 0.075 mm amplitude, 57 to 150 Hz, 9.8 m/s 2 30 min each in X, Y, and Z directions
Shock resistance
(during operation)
147 m/s 2 3 times each in direction of X, Y, and Z
Weight
Degree of protection
Ground
Battery life
Applicable standards
1 kg max.
Equivalent to IP65.
Ground to 100 Ω or less.
5 years (at 25 °C): Replace battery within 5 days after the battery runs low (indicator lights orange).
Certified for conformance to UL 508, EMC Directive, and EN 60204-1.
11
12
NS
Series
Performance/Specifications
NS5
Series
Model
Built-in Ethernet port
Case color
Display device
Effective display area
Display colors
Number of dots
View angle
Screen data capacity
Image data
(BMP or JPG images)
Memory Card
Ladder Monitor function
Video Input Unit support
Controller Link Interface
Unit (Wired) support
Backlight *2
Service life * 3
Brightness adjustment
Backlight error detection *5
Method
NS5-V2
NS5-SQ10-V2 NS5-SQ11-V2 NS5-SQ10B-V2 NS5-SQ11B-V2 NS5-TQ10-V2 NS5-TQ11-V2 NS5-TQ10B-V2 NS5-TQ11B-V2
No Yes No Yes No Yes No Yes
Ivory
TFT color LCD
Black
Width 117.2 × height 88.4 mm (5.7 inches)
256 colors
320 dot horizontal × 240 dot vertical
Left/right: 80 °, Top: 80°, Bottom: 60° *5
60 Mbytes
Ivory
Color High-luminance TFT *1
Black
32,768 colors
Supported
Not supported
Not supported
Not supported
75,000 hours min.
Three-level or 32-level brightness adjustment from the touch panel screen. * 4
Error is detected automatically, and the RUN indicator flashes green as notification.
Matrix resistive membrane
Touch panel
(matrix type)
Display text
Number of switches/ resolution
Input
Service life
Labels
Numerals, alarms, and character strings
Supported languages
(42 languages)
300 (20 horizontal × 15 vertical) 16 × 16 dots for each switch
Pressure-sensitive
1,000,000 touch operations.
Can be specified in CX-Designer. Font, style, and size can be specified.
Scalable Gothic: Magnification: 6 to 255 points
Rough: Magnification:
1
1
×1, 1×2, 2×1, 2×2, 3×3, 4×4, 8×8
×1, 1×2, 2×1, 2×2, 3×3, 4×4, 8×8
7-segment display: Can display only numerals, dates, and times.
Scalable Gothic, rough, standard, and fine can be used for 42 languages.
Japanese, simplified Chinese, traditional Chinese, Korean, English, French, German, Italian, Portuguese, Spain, Swedish, Dutch,
Finnish, Norwegian, Basque, Catalan, Danish, Albanian, Croatian, Czech, Hungarian, Polish, Romanian, Slovak, Slovenian,
Bulgarian, Belarusian, Russian, Serbian, Macedonian, Ukrainian, Georgian, Icelandic, Afrikaans, Faroese, Indonesian, Greek,
Turkish, Estonian, Latvian, Lithuanian, Thai (supported only with scalable Gothic font)
256 colors
Color
Font style
(only when vector font is specified)
Bold or italic
Text attributes
Flicker
Vertical alignment
Horizontal alignment
Objects supporting flicker
Top, center, or bottom
Left-justified, centered, or right-justified
Functional objects: Select from up to 10 types of registered flicker settings. The flicker speed and flicker range can be set.
Fixed objects: Select from three flicker types.
Numeral units and scale settings
1.000 max.
Alarm/event settings
5,000 max.
Expansion interface
For Expansion Interface Units
*1. NS5-TQ series (high luminance TFT) luminance is better than that of NS5-SQ series by about 110 cd/m
2 .
*2. Contact your nearest OMRON representative to replace the backlight.
*3. This is the estimated time before brightness is reduced by half at room temperature and humidity. It is not a guaranteed value.
The service life will be dramatically shortened if PT is used at low temperatures. For example, using the PT at temperatures of 0 °C will reduce the service life to approximately 10,000 hours (reference value).
*4. Lot No. 15Z0 or later of NS5 models.
*5. This function does not indicate that the service life has been reached. It detects when the backlight is not lit due to a disconnection or other errors.
Backlight error detection indicates that all backlights (2) are OFF.
NS
Series
NS8/NS10/NS12/NS15
Series
Model
Built-in Ethernet port
Case color
Display device
Effective display area
NS8-
TV00-
V2
No
Ivory
NS8-V2
NS8-
TV01-
V2
Yes
NS8-
TV00B
-V2
No
Black
NS8-
TV01B
-V2
Yes
High-definition TFT color LCD
Width 170.9
(8.4 inches)
× height 128.2 mm
NS10-
TV00-
V2
No
Ivory
V2
Yes
Width 215.2
(10.4 inches)
NS10-V2
NS10-
TV01-
NS10-
TV00B
-V2
No
Black
NS10-
TV01B
-V2
Yes
High-definition TFT color LCD
× height 162.4 mm
NS12-
TS00-
V2
No
Ivory
NS12-V2
NS12-
TS01-
V2
Yes
NS12-
TS00B
-V2
No
Black
NS12-
TS01B
-V2
Yes
High-definition TFT color LCD
Width 246.0
(12.1 inches)
× height 184.5 mm
NS15-V2
NS15-
TX01S-
V2
Yes
Silver
NS15-
TX01B-
V2
Yes
Black
High-definition TFT color LCD
Width 304.1
× height
228.1 mm
(15 inches)
Display colors
256 colors
Number of dots
View angle
640 dot horizontal
× 480 dot vertical
Left/right: 80
°, Top: 80°,
Bottom: 60
° *3
60 Mbytes
Left/right: 70
Bottom: 65
°, Top: 65°,
° *3
800 dot horizontal vertical
Left/right: 80
Bottom: 80
× 600 dot
°, Top: 80°,
° *3
1,024 dot horizontal
× 768 dot vertical
Left/right: 80
70
°, Top:
°, Bottom: 60°
Screen data capacity
Image data
(BMP or JPG images)
Memory Card
Ladder Monitor function
32,768 colors
Supported
Supported
Video Input Unit support
Supported (Image displayed via video input is 260,000 colors)
(Only RGB input is enabled.)
Controller Link Interface
Unit (Wired) support
Not supported
Service life * 2
50,000 hours min.
Backlight *1
Brightness adjustment
Supported
Three-level or 32-level brightness adjustment from the touch panel screen. * 3
Backlight error detection *4
Error is detected automatically, and the RUN indicator flashes green as notification.
Touch panel
(matrix type)
Display text
Method
Number of switches/ resolution
Input
Service life
Labels
Numerals, alarms, and character strings
Supported languages
(42 languages)
Color
Matrix resistive membrane
768 (32 horizontal
20
× 24 vertical)
× 20 dots for each switch
1,200 (40 horizontal
16
× 30 vertical)
× 16 dots for each switch
1,900 (50 horizontal
16
× 38 vertical)
× 16 dots for each switch
Analog resistive membrane *5
Resolution: 1,024
(horizontal) × 1,024
(vertical)
Pressure-sensitive
1,000,000 touch operations.
Can be specified in CX-Designer. Font, style, and size can be specified.
Scalable Gothic: Magnification: 6 to 255 points
Rough: Magnification: 1 ×1, 1×2, 2×1, 2×2, 3×3, 4×4, 8×8
Standard: Magnification: 1 ×1, 1×2, 2×1, 2×2, 3×3, 4×4, 8×8
Fine: Magnification:
7-segment display:
1 ×1, 1×2, 2×1, 2×2, 3×3, 4×4, 8×8
Can display only numerals, dates, and times.
Scalable Gothic, rough, standard, and fine can be used for 42 languages.
Japanese, simplified Chinese, traditional Chinese, Korean, English, French, German, Italian, Portuguese, Spain, Swedish, Dutch,
Finnish, Norwegian, Basque, Catalan, Danish, Albanian, Croatian, Czech, Hungarian, Polish, Romanian, Slovak, Slovenian,
Bulgarian, Belarusian, Russian, Serbian, Macedonian, Ukrainian, Georgian, Icelandic, Afrikaans, Faroese, Indonesian, Greek,
Turkish, Estonian, Latvian, Lithuanian, Thai (supported only with scalable Gothic font)
256 colors
Text attributes
Font style
(only when vector font is specified)
Vertical alignment
Horizontal alignment
Bold or italic
Top, center, or bottom
Left-justified, centered, or right-justified
Flicker
Objects supporting flicker
Numeral units and scale settings
Alarm/event settings
Expansion interface
Functional objects: Select from up to 10 types of registered flicker settings. The flicker speed and flicker range can be set.
Fixed objects:
1.000 max.
5,000 max.
Select from three flicker types.
For Expansion Interface Units
*1. Contact your nearest OMRON representative to replace the backlight.
*2. This is the estimated time before brightness is reduced by half at room temperature and humidity. It is not a guaranteed value.
The service life will be dramatically shortened if PT is used at low temperatures. For example, using the PT at temperatures of 0 °C will reduce the service life to approximately 10,000 hours (reference value).
*3. Lot No. 28X1 or later of NS8 models, Lot No. 11Y1 or later of NS10 models, Lot No. 14Z1 or later of NS12 models, Lot No. 31114K or later of
NS15 models.
*4. This function does not indicate that the service life has been reached. It detects when the backlight is not lit due to a disconnection or other errors.
Backlight error detection indicates that all backlights (2) are OFF.
*5. An analog touch panel is used with the NS15. Do not press the touch panel in two or more places simultaneously.
If the touch panel is pressed in two or more places simultaneously, it may activate a switch between the points that are pressed.
13
14
NS
Series
Communications
NS5/NS8/NS10/NS12/NS15
Memory Card
Serial
Communications
USB
SLAVE
Specifications
USB HOST
Specifications *1
Port A
Port B
Interface
Functions
Connector
Functions
Connector
Functions
USB rating
Connector
Functions
USB rating
Connector
Functions
One ATA-Compact Flash interface slot
Used to transfer and store screen data, store logging data, and store history data. (Alarm/Event History, Operation
Log, and Error Log generated during Macro execution).
Conforms to EIA RS-232C. D-Sub female 9-pin connector 5-V output (250 mA max.) through pin 6.
The 5-V outputs of serial ports A and B cannot be used at the same time.
Host (PLC) access: 1:N NT Links (connections with CS/CJ/CP-series PLCs and C200HX/HG/HE(-Z) PLCs),
1:1 NT Links, or Host Link (connections with C Series or CVM1/CV-series PLCs)
Direct access to Temperature Controllers using Smart Active Parts:
CompoWay / F and bar code reader connections (Read directly from display.)
Conforms to EIA RS-232C. D-Sub female 9-pin connector. 5-V output (250 mA max.) through pin 6.
The 5-V outputs of serial ports A and B cannot be used at the same time.
Host (PLC) access: 1:N NT Links (connections with CS/CJ/CP-series PLCs and C200HX/HG/HE(-Z) PLCs) or
1:1 NT Links (connections with C Series or CVM1/CV-series PLCs)
Direct access to Temperature Controllers using Smart Active Parts:
CompoWay / F and bar code reader connections (Read directly from display.)
USB1.1
TYPE-B (Slave)
Connection with the CX-Designer (for screen data transfers) Connecting to a PictBridge-compatible Printer
Recommended printers: EPSON: PM-G4500, PX-G5300, PX-5600, EP-901F
Canon: PIXUS MX7600, PIXUS iP100, PIXUS iX5000
USB1.1
TYPE-A (Host)
Connection with a printer (for hard copies)
Recommended printers: EPSON: PX-G930
Built-in Ethernet
Specifications *2
Conformance standards
Conforms to IEEE 802.3/Ethernet (10 Base-T/100 Base-TX).
Functions
Baud rate
Host (PLC) access and connection with the CX-Designer (for screen data transfers)
2 M/1 M/500 K bps
Controller Link (Wiredtype)
Specifications *3
Transmission path
Shielded twisted-pair cable (special cable)
Functions
Resolution
Host (PLC) access and data links
NS-CA001: 320×240, 640×480, 800×600 dots
NS-CA002: User-defined size
NS-CA001: NTSC composite video or PAL
NS-CA002: NTSC composite video or PAL
Video Input Specifications
*4
Input signal
Number of video inputs
NS-CA001: Number of cameras: 4 max.
NS-CA002: 2 cameras + RGB
*1. Except NS5.
*2. NS@-@@@1-V2 only.
*3. Except NS5 and NS8.
*4. Except NS5 and NS15. NS15 provides RGB input. (NS-CA002)
NS
Series
Connectable Devices
Supported OMRON PLCs
RS-232C *1
PLC series PLC model name
C Series
CVM1/CV
Series
CS Series
CJ Series
CQM1
CQM1H
CPM1
CPM1A
CPM2A
CPM2C
C200HS
C200HE (-Z)
C200HG (Z)
C200HX (-Z)
CV500/1000/2000
CVM1
CS1H
CS1G
CS1D
CJ1H
CJ1G
CJ1M
CJ2H
No
No
No
No
Yes
Yes
Yes
Yes
Yes
1:1 NT Link
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
CP Series
CJ2M
CP1H
CP1L
CP1E
NJ5
No
No
No
No
Yes *5
Yes
Yes
Yes
Yes
Yes *5
NJ Series
NJ3 Yes *5 Yes *5
Note:
Including models whose production were discontinued.
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
1:N NT Link
No
Yes
No
No
No
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Host Link
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes *5
Yes *5
Yes
Yes
Yes
Yes
No
No
No
Yes
Yes
FINS *2
No
No
No
No
No
No
No
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
Ethernet
EtherNet/IP *3
No
No
No
No
No
No
No
Yes
Yes
Yes
Yes
No
No
No
No
No
Yes
Yes
Yes
Yes
Yes
No
No
Yes *6
Yes *6
Controller Link *4
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
No
No
No
No
No
Yes
Yes
Yes
Yes
No
No
No
No
No
*1. To connect a NS with a PLC via a RS-422A connection, OMRON's NS-AL002, or CJ1W-CIF11 RS-232C/RS-422A Converter can be used to convert the RS-232C port on the NS to RS-422A.
*2. A NS with Ethernet port is necessary.
When connecting a PLC with the NS, an Ethernet port is necessary on the PLC, too. Use a PLC CPU Unit with a built-in Ethernet port, or add an Ethernet Unit.
*3. A NS with Ethernet port is necessary.
When connecting a PLC with the NS, an EtherNet/IP port is necessary on the PLC, too. Use a PLC CPU Unit with a built-in EtherNet/IP port, or add an EtherNet/IP Unit.
*4. Install a Controller Link Interface Unit on the NS. A Controller Link Unit is necessary for the PLC.
*5. Mount a Serial Communications Unit on the NJ-series Controller. A NS can access only to the Controller's memory used for CJ-series unit.
*6. When using a EtherNet/IP Unit to connect the NJ-series Controller, NJ Troubleshooter is not supported.
15
16
NS
Series
Function Comparison
PLC series PLC model name
Ladder
Monitor
Device Monitor/
Switch Box
PLC Data
Trace
SPMA SAP
EtherNet/IP
Tag access
(Network symbols)
C series
CVM1/CV series
CS series
CJ series
CP series
NJ series
CS1D
CJ1H
CJ1G
CJ1M
CJ2H
CJ2M
CP1H
CP1L
CP1E
NJ5
NJ3
CQM1
CQM1H
CPM1
CPM1A
CPM2A
CPM2C
C200HS
C200HE (-Z)
C200HG (-Z)
C200HX (-Z)
CV500/1000/2000
CVM1
CS1H
CS1G
Note:
Including models whose production were discontinued.
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
No
No
Yes
Yes
No
No
No
No
No
No
No
No
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes *2
Yes *2
No
No
Yes
Yes
No
No
No
No
No
No
No
No
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes *3
Yes *3
No
No
Yes
Yes
No
No
No
No
No
No
No
No
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes *1
Yes *1
Yes *1
No
No
No
No
Yes
Yes
No
No
No
No
No
No
No
No
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
No
No
Yes
Yes
No
No
No
No
No
No
No
No
No
No
*1. The SPMA relaying a PLC is not supported.
*2. Only Device Monitor function is supported. Monitoring function that uses tags (variables) is not supported.
*3. The SAP for CJ-series Special I/O Units and CPU Bus Units that can be used with NJ-series Controller is supported.
*4. Sysmac Studio version 1.02 or higher (CX-Designer version 3.41 or higher) is required.
Yes
Yes
No
No
No
No
No
No
No
Yes
Yes
No
No
No
No
No
No
No
No
No
No
No
No
No
No
Yes
Yes
No
No
Yes
Yes
Yes
Yes
No
No
No
PLC
Troubleshooter
NJ
Troubleshooter/
Integrated
NS-series PT simulation *4
No
No
No
No
No
No
No
No
No
No
No
No
No
No
Yes
Yes
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
Yes
Yes
NS
Series
Connectable Inverters
Series
3G3MX2
3G3JX
3G3RX
Communication Unit
(Use the RS-485 terminal on the Inverter)
(Use the RS-485 connector on the Inverter)
(Use the RS-485 terminal on the Inverter)
RS-485 (2-wire)
Connectable Temperature Controllers
The following Temperature Controllers can be connected directly to an NS-series PT*.
Unit name
Modular Temperature Controller EJ1
Series
EJ1-EDU End Unit
Model
Modular Temperature Controller
Digital Controller
E5ZN
E5AR
E5ER
E5ZN-SCT24S Terminal Unit
E5AR-
@@@@@@@@@-FLK
E5ER@@@@@@@@@-FLK
E5CN-
@@@@@T-FLK Multi-input
(Thermocouple/Resistance Thermometer) Type
E5CN-
@@@@@L-FLK Analog Input Type
E5EN-
@@@@@T-FLK Multi-input
(Thermocouple/Resistance Thermometer) Type
Temperature Controller
(Digital Controller)
E5AN/E5EN/E5CN
(Basic Model)
E5AN-H/E5EN-H/
E5CN-H
(Advanced Model)
E5GN
E5EN@@@@@L-FLK Analog Input Type
E5AN-
@@@@@T-FLK Multi-input
(Thermocouple/Resistance Thermometer) Type
E5AN-
@@@@@L-FLK Analog Input Type
E5CN-H
@@@@@@@-FLK Universal-input Model
E5EN-H @@@@@@@@-FLK Universal-input Model
E5AN-H
@@@@@@@@-FLK Universal-input Model
E5GN-
@@@TC-FLK Thermocouple Input Type
E5GN-
@@@P-FLK Resistance Thermometer Input Type
* The NS-Runtime cannot be connected directly to a Temperature Controller.
Connection
Remarks
SAP screens are available.
1:N
17
18
NS
Series
Connecting to Another Company’s PLC
Manufacturer Series CPU Communication Unit/Adapter/Board Connection diagram
A Series
FX Series
A1SHCPU
A2USCPU
A2USHCPU-S1
A2ACPU
FX0N
FX1S
FX1N
FX1NC
FX2N
FX3UC
FX3G
Q00CPU
Q01CPU
Computer Link Unit
A1SJ71UC24-R
@
A1SJ71UC24-PRF
Computer Link Unit
AJ71UC24
Communication special adapter
FX3U-232-ADP
FX2NC-232ADP
FX0N-232-ADP
Communication expansion board
FX
@@-232-BD
RS-232C port on the CPU Module
RS-232C,
RS422A/485 *1
RS-232C,
RS422A/485 *1
RS-232C
Mitsubishi Electric
Q/QnA Series
Q00CPU
Q01CPU
Q00JCPU
Q02CPU
Q02HCPU
Q06HCPU
Q12HCPU
Q25HCPU
Q03UDCPU
Q06UDHCPU
Q13UDHCPU
Q2ASCPU
Q2ASCPU-S1
Q2ASHCPU
Q2ASHCPU-S1
Serial Communications Module
QJ71C24N-R2
QJ71C24N-R4
QJ71C24N
Serial Communications Module
A1SJ71QC24N
RS-232C,
RS-485 (4-wire) *2
Yokogawa
Electric
FA-M3(R) Series
F3SC23-1F
F3SP21-0N
F3SP28-3S
F3SP58-6S
F3SP67-6S
CPU built-in RS-232C port
Personal Computer Link Module
F3LC11-1F
F3LC12-1F
F3LC11-2F
RS-232C
RS-232C, RS-422A/485 *1
Siemens S7-300 Series
SLC500
CPU313
CPU315-2DP
CPU317-2PN/DP
SLC5/03
SLC5/04
SLC5/05
MicroLogix 1500
SIMATIC S7 HMI Adapter
6ES7 972-0CA1
@-0XA0
RS-232C port on the CPU Module
RS-232C
RS-232C
Rockwell
(Allen-Bradley)
MicroLogix
ControlLogix
CompactLogix
PLC-5
Logix5555
1769-L31
PLC-5/20
RS-232C port on the CPU Module
RS-232C port on the CPU Module
RS-232C port on the CPU Module
RS-232C port or RS-485 port on the
CPU Module
RS-232C
RS-232C
RS-232C
RS-232C/RS-485 (4-wire)
*1. To connect using RS-422A/485, an RS-232C/422A converter (e.g. NS-AL002, CJ1W-CIF11) is required.
*2. To connect using RS-485, an RS-232C/422A converter (e.g. NS-AL002, CJ1W-CIF11) is required.
Up to 32 sequencers can be connected when using RS-485.
1:1
1:N
1:1
1:1
1:1
1:1
1:1
1:1
1:N
1:1
1:1
Component Names and Options
NS15
RS-422A/485 Serial Interface
Memory Card interface
Memory Card
Note:
Colors shown in photographs and product names may differ from actual colors and names.
Expansion interface
Battery
Analog RGB Output
RS-232C serial port A
RS-232C serial port B
A bar code reader can be connected to the serial port.
Recommended bar code reader: V520-RH21-6
Connector for
Brightness Adjustment
Power Supply (24 VDC)
Ethernet (10 Base-T or 100 Base-TX)
USB SLAVE (For transferring screens and connecting a PictBridge-compatible printer)
USB HOST (for printer)
NS12/10
Memory Card interface
Power Supply (24 VDC)
Memory Card
Note:
Colors shown in photographs and product names may differ from actual colors and names.
Expansion interface
Battery
RS-232C serial port A
RS-232C serial port B
A bar code reader can be connected to the serial port.
Recommended bar code reader: V520-RH21-6
Ethernet (10 Base-T or 100 Base-TX)
USB SLAVE (For transferring screens and connecting a PictBridge-compatible printer)
USB HOST (for printer)
NS8
Memory Card interface
NS
Series
Power Supply
(24 VDC)
Expansion interface
Memory Card
Note:
Colors shown in photographs and product names may differ from actual colors and names.
Battery
RS-232C serial port A
RS-232C serial port B
A bar code reader can be connected to the serial port.
Recommended bar code reader: V520-RH21-6
Ethernet (10 Base-T or 100 Base-TX)
USB SLAVE (For transferring screens and connecting a PictBridge-compatible printer)
USB HOST (for printer)
19
NS
Series
NS5
Battery
Power Supply (24 VDC)
NSH5
USB Port Memory Card interface
Enable Switch
LED
Emergency Stop Switch
Memory Card interface
Memory Card
Note:
Colors shown in photographs and product names may differ from actual colors and names.
Expansion interface
Ethernet (10 Base-T or 100 Base-TX)
USB SLAVE (For transferring screens and connecting a PictBridge-compatible printer)
RS-232C serial port A
RS-232C serial port B
A bar code reader can be connected to the serial port.
Recommended bar code reader: V520-RH21-6
Hand Strap
Optional Products
Cable
Function Switches
Video Input Unit
NS-CA001 (with Cover)
RGB/Video Input Unit
NS-CA002 (with Cover)
Controller Link Interface Unit
NS-CLK21 (with Cover)
RS-422A Adapter
CJ1W-CIF11
RS-232C/RS-422A
Conversion Unit
NS-AL002
20
Communications Cable
XW2Z-S002
Protective Cover/Anti-reflection
Sheet for NS-series PT
NS-KBA0 (N)
NT30/NT31C-KBA05 (N)
USB Serial Conversion Cable
CS1W-CIF31
USB relay cable
(IP65 oil-proof type)
NS-USBEXT-1M
Dimensions
NS15
NS
Series
(Units: mm)
Mounting Panel
Mounting Bracket 13.95
79.54
94.8
170
RUN
304
282
304.5
27.4
71.8 57.31
RDA
RDB
SDA
SDB
RSA
RSB
46
3.8
85.6
86.83
405
8
70
75.8
37.9 (min.)
41.1 (max.)
39.4
84.1
Recommended Panel Cutout Dimensions
340
383
405.5
15.5
282.5
+1
−0
NS12/10
264
315
323
15.5
140 241
227 249
7.5
48.5
49
39 (min.)
42 (max.)
383.5
+1
−0
24V
DC
HOST SLAVE
ETHERNET
PORT B PORT A
SW
RESET
121
134
3.8
23
13.7
49.9
90.4
Recommended Panel Cutout
Dimensions
228
+1
−0
302
+1
−0
301
NS8
177 165 188
180
232
15.5
5
48.5
39 (min.)
42 (max.)
49
220
120.5
24V
DC
HOST
ETHERNET
PORT B PORT A
SW
RESET
19.1
107.6
9.6
26.6
44.1 50.1
63.4
Recommended Panel
Cutout Dimensions
165.5
+0.5
−0
220.5
+0.5
−0
NS5
39.83
27.3
44.55
142
RUN
90
195
15.5
145
206.3
130.5
153.3
5
53.8
54.8
34 (min.)
38 (max.)
183.5
19.5
21
51.7
77
ETHERNET
68.48
Recommended Panel
Cutout Dimensions
131
+0.5
−0
184
+0.5
−0
21
22
NS
Series
Hand-held NS5
223
176
16.5
70.5
50
75
75
NS-CA001
Video Input Unit
9.6
(1.9)
(22.3)
10.6
81.3
(102.7)
5
21.4
164
(169)
127.3
50.3
68.3
86.3
104.3
9.7
20.4
11
NS-CA002
Video Input Unit
9.6
(1.9)
(22.3)
11.1
81.3
(102.7)
5
21.4
164
(169)
39.3
57.3
82.8
118.3
9.7
20.4
11
NS-CLK21
Controller Link Interface Unit
151.5
(183)
(1.9)
(33.9)
164
(169)
95.6
31.5
5
10.8
32
11
Related Manuals
Cat. No.
V083
V073
V099
V082
V086
V090
V098
V085
V092
V075
V093
Model
NS15/NS12/NS10/NS8/NS5
NS15/NS12/NS10/NS8/NS5
NS-CXDC1-V3
NS
NS-CA002
NSH5
NS15/NS12/NS10/NS8/NS5
NS15/NS12/NS10/NS8/NS5
NS15/NS12/NS10/NS8/NS5
NS15/NS12/NS10/NS8/NS5
NS-NSRCL
@@
Manual
NS-Series Programmable Terminals SETUP MANUAL
NS-Series Programmable Terminals PROGRAMMING MANUAL
CX-Designer Ver.3.
@ USER'S MANUAL
NS-Series Ladder Monitor OPERATION MANUAL (Ladder Monitor I/O Comment Extracting Tool)
NS-Series RGB and Video Input Unit OPERATION MANUAL
NSH5-Series Hand-held Programmable Terminal OPERATION MANUAL
NS-Series Programmable Terminals HOST CONNECTION MANUAL (Host Link) OPERATION MANUAL
NS-Series Programmable Terminals HOST CONNECTION MANUAL
NS-Series Programmable Terminals HOST CONNECTION MANUAL Multivendor Connection
NS-Series Programmable Terminals Macro Reference
NS-NSRCL
@@ NS-Runtime Software USERS MANUAL
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project