Regulus Heating Element, type P Product sheet 2 Pages
advertisement
G 6/4“ ELECTRIC HEATING ELEMENTS with thermostatic head and contactor
Output:
Application:
2 - 9 kW thermal stores and hot water storage tanks
ETT-P Electric Heating Elements
Nickel-plated resistance heating elements with a thermostatic head and contactor , intended for heating of static heating water or antifreeze fluid in thermal stores or for drinking water heating in hot water storage tanks. These elements are not intended for stainless steel tanks. They are suitable for drinking water heating in hot water storage tanks.
They are designed to be installed in a horizontal position so that the element is completely immersed, the cable gland downwards. They are power supplied by a 7-core cable wired to a terminal box or fuse board.
The heating element features one input for a Ripple control signal and one for master heating system controller.
D I M E N S I O N S , M O D E L S
60
HEATING ELEMENT
CONNECTION
HEXAGON WITH G 6/4“
THREAD
POWER SUPPLY
IP RATING
PROTECTION CLASS BY
EN 61140 ed.2
OPERATING THERMOSTAT
SWITCH-OVER CONTACT
TEMPERATURE
ADJUSTMENT RANGE
TEMPERATURE
ADJUSTMENT METHOD
SWITCHING DIFFERENCE
LOWER LIMIT
UPPER LIMIT
SAFETY THERMOSTAT
SWITCHING TEMP.
RESET
CONTACTOR
COIL VOLTAGE
FREQUENCY nickel plated copper
G 6/4“ M nickel plated brass
400/230V 50 Hz
IP 54
I capillary type, adjustable
16 A from 0 ± 5 °C to 90 ± 3 °C rotating knob
5 ± 1.5 °C about 15 °C
– frost protection about 60 °C
– for HW storage tanks capillary type, fixed setting
99 +0/-6 °C manual, after temperature drops below 80 °C
AC1 : 20 A / 690 V, 1Z
AC 220 – 240 V
50 Hz
72
100
115
LN
L
31
120
MODEL
NOMINAL OUTPUT
NOMINAL CURRENT kW
A
ELEMENT LENGTH (L) mm
NON-HEATING END LENGTH (LN) mm
CODE --
ETT-P
2.0
2.0
2.9
310
180
19041
ETT-P
3.0
3.0
4.3
370
180
19043
ETT-P
4.5
4.5
6.5
500
180
18915
ETT-P
6.0
6.0
8.7
555
180
18386
ETT-P
7.5
7.5
10.8
635
180
19045
ETT-P
8.2
8.2
11.9
700
180
19042
ETT-P
9.0
9.0
13.0
755
180
19044
18 ELECTRIC HEATING ELEMENTS
E L E C T R I C W I R I N G
3/N/PE AC 400/230V
2- 6 kW
POWER CABLE
CROSS SECTION
LENGTH
CABLE GLAND
7,5 - 9 kW
7× 1.5 mm 2
2m
Pg11
RIPPLE CONTROL white
CONTROL red
GREEN GREEN
RIPPLE CONTROL white
CONTROL red
GREEN GREEN
W I R I N G E X A M P L E S
Control via external controller w. Ripple control Control via external controller without Ripple control
3-PHASE CIRCUIT
BREAKER
SINGLE-PHASE
CIRCUIT BREAKER
TERMINAL BOARD IN
A FUSE BOARD OR IN AN
INSTALLATION BOX
CONDUCTORS MARKED
AT CABLE ENDS
CABLE - PART OF HEAT. EL.
HEATING ELEMENT
CONTROLLER W.
230V OUTPUT &
RIPPLE C.
3-PHASE CIRCUIT
BREAKER
SINGLE-PHASE
CIRCUIT BREAKER
TERMINAL BOARD IN
A FUSE BOARD OR IN AN
INSTALLATION BOX
CONDUCTORS MARKED
AT CABLE ENDS
CABLE - PART OF HEAT. EL.
HEATING ELEMENT
CONTROLLER W.
230V OUTPUT
Control via integrated thermostat without Ripple control Control via integrated thermostat w. Ripple control
3-PHASE CIRCUIT
BREAKER
TERMINAL BOARD IN
A FUSE BOARD OR IN AN
INSTALLATION BOX
CONDUCTORS MARKED
AT CABLE ENDS
CABLE - PART OF HEAT. EL.
HEATING ELEMENT
3-PHASE CIRCUIT
BREAKER
TERMINAL BOARD IN
A FUSE BOARD OR IN AN
INSTALLATION BOX
CONDUCTORS MARKED
AT CABLE ENDS
CABLE - PART OF HEAT. EL.
HEATING ELEMENT
- Heating element is heating
- Heating element is OK, power supplied and ready for use.
regulus .
eu ELECTRIC HEATING ELEMENTS 19
advertisement