Regulus Heating Element, type P Product sheet

Add to My manuals
2 Pages

advertisement

Regulus Heating Element, type P Product sheet | Manualzz

G 6/4“ ELECTRIC HEATING ELEMENTS with thermostatic head and contactor

Output:

Application:

2 - 9 kW thermal stores and hot water storage tanks

ETT-P Electric Heating Elements

Nickel-plated resistance heating elements with a thermostatic head and contactor , intended for heating of static heating water or antifreeze fluid in thermal stores or for drinking water heating in hot water storage tanks. These elements are not intended for stainless steel tanks. They are suitable for drinking water heating in hot water storage tanks.

They are designed to be installed in a horizontal position so that the element is completely immersed, the cable gland downwards. They are power supplied by a 7-core cable wired to a terminal box or fuse board.

The heating element features one input for a Ripple control signal and one for master heating system controller.

D I M E N S I O N S , M O D E L S

60

HEATING ELEMENT

CONNECTION

HEXAGON WITH G 6/4“

THREAD

POWER SUPPLY

IP RATING

PROTECTION CLASS BY

EN 61140 ed.2

OPERATING THERMOSTAT

SWITCH-OVER CONTACT

TEMPERATURE

ADJUSTMENT RANGE

TEMPERATURE

ADJUSTMENT METHOD

SWITCHING DIFFERENCE

LOWER LIMIT

UPPER LIMIT

SAFETY THERMOSTAT

SWITCHING TEMP.

RESET

CONTACTOR

COIL VOLTAGE

FREQUENCY nickel plated copper

G 6/4“ M nickel plated brass

400/230V 50 Hz

IP 54

I capillary type, adjustable

16 A from 0 ± 5 °C to 90 ± 3 °C rotating knob

5 ± 1.5 °C about 15 °C

– frost protection about 60 °C

– for HW storage tanks capillary type, fixed setting

99 +0/-6 °C manual, after temperature drops below 80 °C

AC1 : 20 A / 690 V, 1Z

AC 220 – 240 V

50 Hz

72

100

115

LN

L

31

120

MODEL

NOMINAL OUTPUT

NOMINAL CURRENT kW

A

ELEMENT LENGTH (L) mm

NON-HEATING END LENGTH (LN) mm

CODE --

ETT-P

2.0

2.0

2.9

310

180

19041

ETT-P

3.0

3.0

4.3

370

180

19043

ETT-P

4.5

4.5

6.5

500

180

18915

ETT-P

6.0

6.0

8.7

555

180

18386

ETT-P

7.5

7.5

10.8

635

180

19045

ETT-P

8.2

8.2

11.9

700

180

19042

ETT-P

9.0

9.0

13.0

755

180

19044

18 ELECTRIC HEATING ELEMENTS

E L E C T R I C W I R I N G

3/N/PE AC 400/230V

2- 6 kW

POWER CABLE

CROSS SECTION

LENGTH

CABLE GLAND

7,5 - 9 kW

7× 1.5 mm 2

2m

Pg11

RIPPLE CONTROL white

CONTROL red

GREEN GREEN

RIPPLE CONTROL white

CONTROL red

GREEN GREEN

W I R I N G E X A M P L E S

Control via external controller w. Ripple control Control via external controller without Ripple control

3-PHASE CIRCUIT

BREAKER

SINGLE-PHASE

CIRCUIT BREAKER

TERMINAL BOARD IN

A FUSE BOARD OR IN AN

INSTALLATION BOX

CONDUCTORS MARKED

AT CABLE ENDS

CABLE - PART OF HEAT. EL.

HEATING ELEMENT

CONTROLLER W.

230V OUTPUT &

RIPPLE C.

3-PHASE CIRCUIT

BREAKER

SINGLE-PHASE

CIRCUIT BREAKER

TERMINAL BOARD IN

A FUSE BOARD OR IN AN

INSTALLATION BOX

CONDUCTORS MARKED

AT CABLE ENDS

CABLE - PART OF HEAT. EL.

HEATING ELEMENT

CONTROLLER W.

230V OUTPUT

Control via integrated thermostat without Ripple control Control via integrated thermostat w. Ripple control

3-PHASE CIRCUIT

BREAKER

TERMINAL BOARD IN

A FUSE BOARD OR IN AN

INSTALLATION BOX

CONDUCTORS MARKED

AT CABLE ENDS

CABLE - PART OF HEAT. EL.

HEATING ELEMENT

3-PHASE CIRCUIT

BREAKER

TERMINAL BOARD IN

A FUSE BOARD OR IN AN

INSTALLATION BOX

CONDUCTORS MARKED

AT CABLE ENDS

CABLE - PART OF HEAT. EL.

HEATING ELEMENT

- Heating element is heating

 - Heating element is OK, power supplied and ready for use.

regulus .

eu ELECTRIC HEATING ELEMENTS 19