Regulus TVmix Anti-Scald Valve, G 3/4" M, ZV, recirculation Technical Data Sheet
Advertisement
Advertisement
Main Features
Description
Working fluid
Installation
Code
Connection Diagram
DATA SHEET
Anti-Scald Valve with a Recirculation Connection Kit
v1.0_05/2019 str.1/2
Used in DHW systems with recirculation. It consists of:
• anti-scald valve of TVmix type
• housing of recirculation connection kit with 3 integrated non-return valves
• connecting fittings
An anti-scald valve ensures such mixing cold and hot water from a heater that the outgoing water is of the preset temperature. If cold water supply is interrupted, the valve closes hot water supply to avoid scalding at the outlet point.
Non-return valves prevent water backflow to recirculation and cold water piping.
drinking water following the connection diagram; the flow direction marked by arrows on the housing shall be respected
17602
Technical Data
Max. working pressure 10 bar
Working temperature range
5 to 95 °C
Adjustable temperature range
35 to 65 °C ± 3°C
Materials
Load valve housing
Kit housing
Valve cap
Non-return valve body
Non-return valve O-ring
Other Data
Kvs
Weight
Connections
DZR brass CW625N (dezincification-resistant)
DZR brass CW625N (dezincification-resistant) plastic
POM Hostaform
EPDM
1.6 m
1.4 kg
3
/h
G 3/4" M outlet point anti-scald valve
cc
HW storage tank
recirculation connection kit cold water recirculation hot water
H hot water in
C cold water in
M mixed water out
CC recirculation pump
R E G U L U S spol. s r.o.
Do Koutů 1897/3, 143 00 Praha 4
Tel.: +420 241 764 506
Fax: +420 241 763 976
E-mail: [email protected]
Web: www.regulus.cz
DATA SHEET
Pressure Drop Diagram
Anti-Scald Valve with a Recirculation Connection Kit
v1.0_05/2019 str.2/2
Dimensions