Wincor Nixdorf D1064 Operator Manual
Wincor Nixdorf D1064 is a customer display intended for customer/partner use. It can be used for a variety of purposes, including displaying customer information, transaction details, and marketing messages. The D1064 is a versatile device that can be mounted on a stand, pole, or A-Series AIO or display. It is also easy to use and maintain, making it a great choice for businesses of all sizes.
Advertisement
Advertisement
D1064
Customer Display
Operator Manual
01750364416 B
Customer/Partner Use
This document is property of Diebold Nixdorf and is intended for customer/partner use. A written license agreement with Diebold Nixdorf is not required to use this material.
Copyright © Diebold Nixdorf. Copyright protection is claimed for each revision listed in the document history, as of the date indicated. All Rights Reserved.
This document contains proprietary information of Diebold Nixdorf, Incorporated or its subsidiaries (collectively “ Diebold Nixdorf “) and may include information that is protected by copyright, trademark and patent laws in the US, Germany, and globally. All rights, including rights created by patent grants or registration of a utility model or design, are reserved.
No part of this document may be translated, reproduced, stored in a retrieval system, or transmitted, in any form or by any means: electronic, mechanical, photocopying, recording, or otherwise, without prior written permission from Diebold Nixdorf. Any violations of the foregoing may give rise to a claim for damages.
If the document pages state the information is confidential (or words of similar import), then this document is intended solely for the use of the employees or other personnel of Diebold Nixdorf unless expressly authorized in writing by Diebold Nixdorf. Other uses of this information without the express written consent of Diebold Nixdorf are prohibited.
This document should be treated as confidential material for security reasons. Any unauthorized disclosure or use of confidential material may violate the U.S. Theft of Trade Secrets provisions of Section 1832 of Title 18 of the United States Code as well as comparable laws in other jurisdictions throughout the world, and may be punishable by fine and imprisonment.
This document and the information contained herein are provided AS IS AND WITHOUT WARRANTY.
In no event shall Diebold Nixdorf or its suppliers be liable for any special, indirect, or consequential damages of any nature resulting from the use of information in this manual. The information contained in this document is subject to change without notice. When using the document for system implementation, please call your authorized Diebold Nixdorf sales or service representative for any applicable changes.
Any trademarks, service marks, product names or company names not owned by Diebold Nixdorf, that appear in this document are used for informational purposes only, and Diebold Nixdorf claims no rights thereto, nor does such use indicate any affiliation with or any endorsement of Diebold Nixdorf or Diebold
Nixdorf products by the owners thereof.
Your use of this document and/or any of the information contained herein constitutes your agreement to all of the terms stated on this page.
Copyright © 2022, Diebold Nixdorf
01750364416 B ii
Table of Contents
Copyright © 2022, Diebold Nixdorf
01750364416 B iii
Table of Contents
Copyright © 2022, Diebold Nixdorf
01750364416 B iv
Table of Contents
Illustration directory
Copyright © 2022, Diebold Nixdorf
01750364416 B v
1 Document History
Part Number
01750364416 A
01750364416 B
Date
02/2022
04/2022
Remarks
Creation of the manual
Addition of part numbers and smaller improvements
1
Copyright © 2022, Diebold Nixdorf
01750364416 B
1-1
2 About This Manual
This documentation is intended to help you to work with the customer display and to serve as a reference work. The detailed table of contents helps you find the desired information quickly and easily.
NOTE
Note
This is how notes are displayed in this manual.
2
WARNING
Warning
This is how warnings are displayed in this manual.
Copyright © 2022, Diebold Nixdorf
01750364416 B
2-1
3 Introduction
The D1064 is a rejuvenate successor of the BA64-2 Customer Display for the A-Series Family of POS system. The radiant and high contrast nature of the VFD technology makes it an excellent choice for a customer display. The D1064 operates in either USB or RS232 mode depending on the cable option you select. There are three mounting options to choose from, for mounting on the back of the A-Series POS terminal, pole-mount or standalone on the counter top.
3.1
3.1
Features at a glance
• VFD version allow for worldwide application
• Backward compatible to BA63/BA64
• Epson ESC POS command set support
• Loadable character sets
• Unicode support
• JavaPOS 1.13 support
• Flexible mounting options
3.2
3.2
Care of D1064
Clean your customer display regularly with an appropriate surface cleaning product.
Make sure that the device is switched off and that no moisture is allowed to get into the inside of the device.
3
Copyright © 2022, Diebold Nixdorf
01750364416 B
3-1
4 Manufacturer’s Declaration and Approval
General authorization
This device complies with the requirements of the directive 2014/30/EC with regard to “Electromagnetic Compatibility” and 2014/35/EC "Low Voltage Directive" and RoHS directive 2011/65/EU.
Therefore, you will find the CE mark on the device or packaging.
4
FCC-Class A Declaration
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his expense.
Modifications not authorized by the manufacturer may void users’ authority to operate this device.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference, including interference that may cause undesired operation.
CAN ICES-3 (A)/NMB-3 (A)
Copyright © 2022, Diebold Nixdorf
01750364416 B
4-1
Manufacturer’s Declaration and Approval
Safety information
This device conforms to the corresponding safety regulations for information technology devices, including electronic office machines for use in the office environment.
• If the device is moved from a cold environment to a warmer room where it is to be operated, condensation could occur. The device must be completely dry before being put into operation. Therefore an acclimatization time of at least two hours should be accounted for.
• Lay all cables and supply lines so that nobody can tread on them or trip over them.
• Data cables should neither be connected nor removed during electrical storms.
• This equipment is not suitable for use in locations where children are likely to be present.
• Protect the device from vibrations, dust, moisture and heat, and only transport the device in its original packaging (to protect it against impact and blows).
• Take care to ensure that no foreign objects (e.g. paper clips) or liquids can get into the inside of the device, as this could cause electrical shocks or short circuits.
• In case of emergencies (e.g. damaged housing, liquid or foreign objects getting into the device), the device should be switched off immediately, the mains plug of the BEETLE or PC should be removed, and the Diebold Nixdorf customer service should be contacted.
Generally you should connect IT-devices only to power supply systems with separately guided protective earth conductor (PE), known as TN-S networks. Do not use PEN conductors! Please also observe the recommendations of the norm DIN VDE 0100, part 540, Appendix C2, as well as EN50174-2, §5.4.3.
Warranty
Diebold Nixdorf guarantees generally a warranty engagement for 12 months beginning with the date of delivery. This warranty engagement covers all those damages which occur despite a normal use of the product.
Damages because of
• improper or insufficient maintenance,
• improper use of the product or unauthorized modifications of the product,
• inadequate location or surroundings will not be covered by the warranty.
For further information of the stipulation, look at your contract.
All parts of the product which are subject to wear and tear are not included in the warranty engagement.
Please order spare parts at the Diebold Nixdorf customer service.
Copyright © 2022, Diebold Nixdorf
01750364416 B
4-2
Manufacturer’s Declaration and Approval
Instructions for maintenance
Clean your display regularly with an appropriate surface cleaning product. Make sure that the device is switched off, connector cables are unplugged and that no moisture is allowed to get into the inside of the device.
Please observe the maintenance and cleaning instructions for each of the components. These instructions can be found in their respective chapters.
Recycling
Environmental protection does not begin when time comes to dispose of the display; it begins with the manufacturer. The compact display is manufactured without the use of CFCs and CCHS and is produced mainly from reusable components and materials.
The processed plastics can, for the most part, be recycled. Even the precious metals can be recovered, thus saving energy and costly raw materials. Please do not stick labels onto plastic case parts. This would help us to re-use components and material.
You can protect our environment by switching on your display only when it is actually needed. If possible, even avoid the stand-by-mode as this wastes energy, too. Also switch your display off when you take a longer break or finish your work.
There are still some parts that are not reusable. Diebold Nixdorf guarantees the environmentally safe disposal of these parts in a Recycling Center, which is certified pursuant to ISO 9001 and ISO 14001.
So don’t simply throw your device on the scrap heap when it has served its time, but take advantage of the environmentally smart, up-to-date recycling methods.
Please contact your competent branch or the Recycling Center Paderborn (for European countries) for information on how to return and re-use devices and disposable materials under the following mail address:
Email: [email protected]
We look forward to your mail.
Copyright © 2022, Diebold Nixdorf
01750364416 B
4-3
5 Supplier’s Declaration of Conformity
Product Description: Customer Display
Model: D1064
Party issuing Supplier’s Declaration of Conformity
Diebold Nixdorf Singapore PTE. LTD.
30A Kallang Place, #04-01
Singapore 339213
Phone: +65 6747 3828
Responsible Party – U.S. Contact Information
Diebold Nixdorf
50 Executive Pkwy
PO Box 2520
Hudson, OH 44236 / USA
Phone: +1 330 490 5049
FCC Compliance Statement (for products subject to Part 15)
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
5
Copyright © 2022, Diebold Nixdorf
01750364416 B
5-1
6 Overview
Below you will find reference pictures showing the D1064 in various installation situations. The installation components, such as the pole itself, are not part of the scope of delivery of the D1064.
6
NOTE
The pictures may differ in detail from the product you received.
6.1
6.1
D1064 on a stand
Figure 6-1: D1064 mounted on a Stand
Copyright © 2022, Diebold Nixdorf
01750364416 B
6-1
Overview
6.2
D1064 on a pole
6.2
Figure 6-2: D1064 mounted on a pole
Copyright © 2022, Diebold Nixdorf
01750364416 B
6-2
Overview
6.3
D1064 on a A-Series AIO or Display
6.3
Figure 6-3: D1064 on a A-Series AIO or Display
Copyright © 2022, Diebold Nixdorf
01750364416 B
6-3
7 Initial Setup
In this chapter you will find the information you need to prepare for the installation of the system.
7.1
Unpacking and Checking the Delivery Unit
Unpack the parts and check whether the delivery corresponds to the information on the delivery note.
The delivery includes the respective screen module.
Mounting adapters can be ordered separately depending on the intended installation situation. Data cables required for operation can be ordered separately. If damage has occurred during transport or the contents of the package do not match the delivery note, inform your Diebold Nixdorf sales office immediately.
Only transport the unit in its original packaging.
7.2
7.2
Mounting Options and Connection Cables
7.1
7
Various mounting options and connection cables are available for installing the BA64 in the different installation scenarios.
The mounting options and cables must be purchased separately from the main unit.
The following list shows an overview of the D1064 configuration components and their detailed contents.
D1064 consists of:
Illustration Item
1x D1064 Display
4x Torx screw M4x6 with black zinc
Copyright © 2022, Diebold Nixdorf
01750364416 B
7-1
Initial Setup
Stand consist of:
Illustration Part Number
01750279877
Item
1x Stand Assembly
Pole Adapter consists of:
Illustration Part Number
01750279878
Item
1x Pole mount assembly
A-Series dual display adapter consists of:
Illustration Part Number
01750342563
Item
1x Display adapter
2x Torx countersunk screws M4x8
(Part number: 01750335349)
Copyright © 2022, Diebold Nixdorf
01750364416 B
7-2
Initial Setup
Connection cables:
Illustration Part Number
01750243981
01750243983
01750243985
01750349276
Item
USB to RJ45 cable, 1.5m, black
USB to RJ45 cable, 3.0m, black
USB to RJ45 cable, 5.0m, black
RJ45 to USB cable (0,42.)
01750243975
01750243977
01750243979
RS232 to RJ45 cable, 1.5m, black
RS232 to RJ45 cable, 3.0m, black
RS232 to RJ45 cable, 5.0m, black
Copyright © 2022, Diebold Nixdorf
01750364416 B
7-3
Initial Setup
7.3
Installing the D1064 Display
7.3.1
Installing System to the Stand
To install the D1064 Display to a pole you will need the following parts:
Illustration Item
1x Unit of D1064 Display
1x Unit of Stand
7.3
7.3.1
1x Unit of connection cable
Copyright © 2022, Diebold Nixdorf
01750364416 B
7-4
Initial Setup
1.
Thread the RJ45-end of the connection cable through the stand.
Figure 7-1: Threading the cable through the stand
2.
Connect the RJ45 connector (1) to the D1064
Figure 7-2: Connect the RJ45 cable
Copyright © 2022, Diebold Nixdorf
01750364416 B
7-5
Initial Setup
3.
Secure the cable in the strain relief (1) at the back of the D1064.
Figure 7-3: Secure the RJ45 cable
4.
Secure the D1064 with two ‚Torx screw
M4x6‘ (1) to the stand.
Figure 7-4: Secure the Display to the stand
Copyright © 2022, Diebold Nixdorf
01750364416 B
7-6
Initial Setup
5.
Secure the cable in the strain relief (1) at the base of the stand.
Figure 7-5: Secure cable in the stand
• Display D1064 mounted on a stand.
Figure 7-6: Finished installation
Copyright © 2022, Diebold Nixdorf
01750364416 B
7-7
Initial Setup
7.3.2
Installing System to the Pole
To install the D1064 Display to a pole you will need the following parts:
Illustration Item
1x Unit of D1064 Display
1x Unit of Pole mount adapter
1x Unit of connection cable
7.3.2
Copyright © 2022, Diebold Nixdorf
01750364416 B
7-8
Initial Setup
1.
Thread the RJ45-end of the connection cable through the pole and the pole adapter.
2.
Slide the pole mount adapter onto the pole.
Figure 7-7: Mount adapter to pole
3.
Connect the RJ45 connector (1) the the
D1064.
Figure 7-8: Connect the cable
Copyright © 2022, Diebold Nixdorf
01750364416 B
7-9
Initial Setup
4.
Secure the cable in the strain relief (1) at the back of the D1064.
Figure 7-9: Attach cable to strain relief
5.
Secure the D1064 with two ‚Torx Screws
M4x6’ (1) to the adapter.
Figure 7-10: Mount the Display to the adapter
Copyright © 2022, Diebold Nixdorf
01750364416 B
7-10
Initial Setup
6.
Locate the screw hole on the pole.
7.
Use a M3 screw to secure the D1064 and pole mount adapter assembly to the pole.
Figure 7-11: Secure adapter on the pole
• Display D1064 mounted on a pole.
Figure 7-12: Finished installation
Copyright © 2022, Diebold Nixdorf
01750364416 B
7-11
Initial Setup
7.3.3
Installing System to a A-Series AIO or Display
To install the D1064 Display to a A-Series AIO or Display you will need the following parts:
Illustration Item
1x Unit of D1064
7.3.3
1x Unit of A-Series dual disaply adapter for D1064
1x Unit of connection cable (0,5m)
Copyright © 2022, Diebold Nixdorf
01750364416 B
7-12
Initial Setup
1.
Pull the VESA cover downwards from the stand (1).
1
Figure 7-13: Remove the VESA cover
2.
Remove the breakaway (1) from the VESA cover.
Figure 7-14: Remove the breakaway
Copyright © 2022, Diebold Nixdorf
01750364416 B
7-13
Initial Setup
3.
Remove the cable cover (1) from the Beetle
A-series system.
Figure 7-15: Removing the cable cover
1
1
4.
Loosen the M3x8 screws (2) slighty.
5.
Remove the mounting adapter (1).
Figure 7-16: Loosen adapter screws
Copyright © 2022, Diebold Nixdorf
01750364416 B
7-14
Initial Setup
1
6.
Position the RJ45 connector (2) with the lock clip side parallel to the adapter sides.
7.
Thread the RJ45 connector through the adapter (1).
2
Figure 7-17: Threading the RJ45 cable
8.
Remove the M4x6 torx screws (1) from the
D1064.
Figure 7-18: Removing screws from the D1064
Copyright © 2022, Diebold Nixdorf
01750364416 B
7-15
Initial Setup
1
9.
Connect the RJ45 connector (1) the the
D1064 display.
10. Secure the cable in the strain relief (2) at the back of the display.
2
Figure 7-19: Connecting the RJ45 plug
2
11. Insert the mounting adapter (2) and secure it with the previously removed screws (1).
Figure 7-20: Mounting the adapter to D1064
Copyright © 2022, Diebold Nixdorf
01750364416 B
7-16
Initial Setup
12. Remove two M4x8 countersunk torx screws
(1) at the top.
Figure 7-21: Removing top screws
1
13. Insert the mounting adapter (1) as directed by the arrow.
14. Secure the mounting adapter with the previously removed screws (2).
Figure 7-22: Mounting the adapter to the stand
Copyright © 2022, Diebold Nixdorf
01750364416 B
7-17
Initial Setup
1
15. Slot in the D1064 assembly (1) to the mounting adapter.
16. Tighten the previously loosened M3x8 torx screws (2).
Figure 7-23: Mount the Display to the adapter
17. Thread the USB cable trough the gap between the Beetle and the marked beam.
Figure 7-24: Threading the USB cable
Copyright © 2022, Diebold Nixdorf
01750364416 B
7-18
Initial Setup
1
18. Connect the USB cable to an available USB port (1).
Figure 7-25: Connect the cable
19. Attach the cable cover (1) to the Beetle A-series system.
Figure 7-26: Mounting the cable cover
1
Copyright © 2022, Diebold Nixdorf
01750364416 B
7-19
Initial Setup
Figure 7-27: Cable routing overview
20. Push the cable into the cable channel from the mounting adapter.
21. Bend the cable in a 90° angle (1).
22. Bend the cable at (2) and (3).
23. Lay the cable into the cable channel (4).
NOTE
Cabble routing
Make sure the cable stays in position when attaching the VESA cover to the stand.
Copyright © 2022, Diebold Nixdorf
01750364416 B
7-20
Initial Setup
24. Push the VESA cover upwards to mount it to the stand (1).
1
Figure 7-28: Mount the VESA cover
• Display D1064 mounted on a A-Series AIO or
Display
Figure 7-29: Finished installation
Copyright © 2022, Diebold Nixdorf
01750364416 B
7-21
8 Display Characteristics
8.1
Screen Coordinates
The D1064 is a text display of 2 rows by 20 characters.
Each character has a resolution of 5 pixels width and 7 pixels height.
8.1
8
1
1
2
20
The origin of the coordinate system is at the top-left corner of the screen as shown above.
Copyright © 2022, Diebold Nixdorf
01750364416 B
8-1
9 Display Commands
9.1
Control Characters and ESC Sequences
The table below is a summary of the control characters and escape sequences supported by the D1064.
9.1
9
Command
BS
LF
CR
ESC [ 0 K
ESC [ 2 J
ESC [ <y> ; <x> H
ESC R <n>
ESC [ 0 c
ESC [ 1 c
ESC [ 2 c
ESC [ <n> ; <m> S
ESC [ <n> E
ESC [ E
ESC [ <n> u
ESC [ u
ESC [ 0 ?
Description
Backspace
Line Feed
Carriage Return
Delete to End of Line
Clear Screen
Set Cursor Position
Set Country Code
Call Display Identification
Character Set Identification
Firmware Identification
Set Baud Rate for Serial Interface
Set Display Mode
Read Current Display Mode
Set Character Encoding/Decoding Mode
Read Character Encoding/Decoding Mode
Execute Self-Test
Copyright © 2022, Diebold Nixdorf
01750364416 B
9-1
Display Commands
9.1.1
Backspace
Code
BS
Hexadecimal
08
Description:
This command moves the cursor one position to the left. If there is a character in the position to which the cursor moves, the character is not deleted. This command is ignored if the cursor is already at the first position of the row.
9.1.2
Line Feed
9.1.2
9.1.1
Code
LF
Hexadecimal
0A
Description:
This command moves the cursor one row down; the column position of the cursor remains unchanged. If the cursor is on the last row the screen scrolls up a row and the position of the cursor remains unchanged.
9.1.3
9.1.3
Carriage Return
Code
CR
Hexadecimal
0D
Description:
This command moves the cursor to the beginning of the row in which it is currently positioned. This command is ignored if the cursor is already at the beginning of the row.
9.1.4
9.1.4
Delete to End of Line
Code
ESC [ 0 K
Hexadecimal
1B 5B 30 4B
Description:
This command deletes the characters from the cursor, including the cursor position to the end of the row.
The position of the cursor remains unchanged.
Copyright © 2022, Diebold Nixdorf
01750364416 B
9-2
Display Commands
9.1.5
Clear Screen
Code
ESC [ 2 J
Hexadecimal
1B 5B 32 4A
Description:
This command clears all content on the screen. The cursor position remains unchanged.
9.1.6
Set Cursor Position
Code
ESC [ < y > ; < x > H
Hexadecimal
1B 5B < y > 3B < x > 48
Description:
This command positions the cursor to the specified basic cell position. The cursor is not visible. Parameter < y > and < x > are 1 and 2 ASCII decimal numbers respectively. If < y > or < x > is 0, it is interpreted as 1, and if they are greater than the maximum column or row it is interpreted as the maximum. If < y >, < x > and the ';' in between are dropped, the cursor is positioned at the home position, i.e. coordinate (1,1).
Notes:
1.
Default position of cursor is (1,1).
2.
Valid ranges of value are 1 to 2 for <y> and 1 to 20 for <x> .
9.1.6
9.1.5
Copyright © 2022, Diebold Nixdorf
01750364416 B
9-3
Display Commands
9.1.7
Set Country Code
Code
ESC R < n >
Hexadecimal
1B 52 < n >
<n> is a hexadecimal byte value that represents the country code. The supported country codes are listed below:
0C
30
31
09
0A
0B
32
33
34
35
04
05
06
07
08
01
02
03
Country
Code
00 -
Code
Page
Character Set
USA
-
-
-
France
Germany
Great Britain
-
-
-
-
-
Denmark 1
Sweden
Italy
Spain
Japan
-
-
-
-
437
850
852
857
858
866
Norway
Denmark 2
Spain 2
Latin America
Standard
Latin 1
Latin 2
Latin 5 / Turkey
Latin 1
Latin / Cyrillic
45
46
47
41
42
44
48
49
4A
63
3A
3B
3C
3E
40
37
38
39
Country
Code
36
Code
Page
737
Character Set
Latin / Greek 2
862
775
Latin / Hebrew
IBM831 Latin / Greek 2
Baltic Rim
855
860
861
863
865
Cyrillic
Portugese
Icelandic
French / Canada
Nordic
869
1255
1257
1258
897
Greek 2
1250 Latin 2 / Central Europe
1251 Cyrillic / Slavic
1252 Latin 1 / ANSI
1253 Greek
1254 Latin 5 / Turkish
Hebrew
Baltic Rim
Vietnamese
Japan / Katakana
Description:
This command set the specific character set for the respective country code defined by parameter < n> as shown above.
Notes:
1.
The default is the USA character set ( n = 00 ).
2.
This command is not supported in UTF-8 and UTF-16 mode.
Copyright © 2022, Diebold Nixdorf
01750364416 B
9-4
9.1.7
Display Commands
9.1.8
Display Identification
Code
ESC [ 0 c
Description:
This command returns the display characteristics.
Response:
Hexadecimal
1B 5B 30 63
Code
ESC [ ? <p1>; <p2>;<p3>;<p4>;<p5> c
Hexadecimal
1B 5B 3F <p1> 3B <p2> 3B <p3> 3B <p4> 3B
<p5> 63 where:
<p1> Type of display
<p2> Firmware version
<p3> Character set
<p4> Number of rows
<p5> Column / Line
D1064
2 = VFD
One ore more ASCII coded decimal number
Two ASCII coded alphanumeric character of the currently selected country code.
If country code is not defined for the current codepage <p3> shall be empty.
2
20
Notes:
1.
This command is not supported in USB mode.
9.1.8
Copyright © 2022, Diebold Nixdorf
01750364416 B
9-5
Display Commands
9.1.9
Character Set Identification
Code
ESC [ 1 c
Hexadecimal
1B 5B 31 63
Description:
This command returns the country codes of the external character sets currently installed.
Response:
Code
ESC [ ? <cp1>;<cc1>;<cp2>;<cc2>;
[…] ;<cp n >;<cc n > c
Hexadecimal
1B 5B 3F <cp1> 3B <cc1> 3B […] 3B <cp n > 3B
<cc n > 63 where: cp1 , cp2 , … and cc1 , cc2 , … are the code pages and country codes respectively.
Notes:
1.
This command is not supported in USB mode.
9.1.10 Firmware Identification
9.1.10
Code
ESC [ 2 c
Hexadecimal
1B 5B 32 63
Description:
This command returns the boot and main firmware version numbers.
Response:
Code
ESC [ ? <p1> <p2>;<p3> <p4> c
Hexadecimal
1B 5B 3F <p1> <p2> 3B <p3> <p4> 63 where:
– p1 and p2 are the boot firmware version and subversion number
– p3 and p4 are the main firmware version and subversion number.
Notes:
1.
This command is not supported in USB mode.
9.1.9
Copyright © 2022, Diebold Nixdorf
01750364416 B
9-6
Display Commands
9.1.11 Set Compatibility Mode
Code
ESC [ < n > E n is a ASCII coded decimal number defined as follow:
Hexadecimal
1B 5B < n > 45 n Display Mode
1 Set BA64 Native Mode (default)
2 Set ESC/POS Mode
3 Set BA63 Emulation Mode
Description:
This command is to switch to the selected compatible mode. Sending this command will change the setting and save to flash (non-volatile).
Notes:
1.
When set to mode 3, the encoding mode is automatically restored to ASCII mode.
9.1.12 Read Current Compatibility Mode
9.1.12
Code
ESC [ E
Hexadecimal
1B 5B 45
Description:
This command returns the current compatibility mode. The response format is as shown below.
Response:
Code
ESC [ < n > E n is a ASCII coded decimal number:
Hexadecimal
1B 5B < n > 45 n Display Mode
1 BA64 Native Mode
2 ESC/POS Mode
3 BA63 Emulation Mode
Notes:
1.
This command is not supported in USB mode.
9.1.11
Copyright © 2022, Diebold Nixdorf
01750364416 B
9-7
Display Commands
9.1.13 Set Baud Rate for Serial Port
Code
ESC [ < n > ; < m > S
Hexadecimal
1B 5B < n > 3B < m > 53
Description:
This command defines the baud rate and the control byte for the serial port.
n Baud rate
01 110 bps
02 300 bps
03 600 bps
04 1200 bps
05 2400 bps
06 4800 bps
07 9600 bps
08 14400 bps
09 19200 bps
0A 38400 bps
0B 56000 bps
0C 57600 bps
0D 115200 bps m Control Byte
0 – 1 11 = 8-Bit Data (fixed)
2 0 = 1 stop bit (default)
1 = 2 top bits
3 0 = Disable parity
1 = Enable parity (default)
4 – 5 00 = Odd parity (default)
01 = Even parity
10 = Forced ‘1’ stick parity
11 = Forced ‘0’ stick parity
6 – 7 Fixed at 00
Note:
1.
This command is applicable only to the RS232C interface.
2.
This command is not applicable in Unicode mode, use the alternate command instead, see
9.1.13
Copyright © 2022, Diebold Nixdorf
01750364416 B
9-8
Display Commands
9.1.14 Set Serial Port
Code
ESC [ < b >;< d >;< p >;< s > s
Hexadecimal
1B 5B < b > 3B < d > 3B < p > 3B < s > 73
Description:
This is an alternate command to set the serial communication settings. The parameters are ASCII coded decimal values or alphabetical character:
Parameter b Baud rate d Data length p Parity
Values
9600 to 115200
7 or 8
0 = none
1 = odd
2 = even
1 or 2 s Stop bit
Notes:
1.
This command is not applicable in USB mode.
9.1.15 Set Character Encode/Decode Mode
9.1.15
Code
ESC [ < n > u n is a ASCII coded decimal number defined as follow:
Hexadecimal
1B 5B < n > 75 n Display Mode
0 Set ASCII Encode/Decode mode
1 Set UTF-8 Encode/Decode mode
2 Set UTF-16 Encode/Decode mode
Description:
An encode/decode mode change resets the display.
9.1.14
Copyright © 2022, Diebold Nixdorf
01750364416 B
9-9
Display Commands
9.1.16 Read Character Encode/Decode Mode
Code
ESC [ u
Hexadecimal
1B 5B 75
Description:
This command returns the current compatibility mode. The response format is as shown below.
Response:
Code
ESC [ < n > u n is a ASCII coded decimal number.
Hexadecimal
1B 5B < n > 75 n Display Mode
0 ASCII Encode/Decode mode
1 UTF-8 Encode/Decode mode
2 UTF-16 Encode/Decode mode
Notes:
1.
This command is not supported in USB mode.
9.1.17 Start Self-Test
Code
ESC [ 0 ?
Hexadecimal
1B 5B 30 3F
Description:
This command starts a self-test in an endless loop. The self-test stops and returns to normal operation when the device received any data.
9.1.18 Restore Configuration Data to Factory Default
9.1.18
Code
ESC + 0 w
Hexadecimal
1B 2B 30 77
Description:
This command restores all settings to the factory default configuration.
9.1.16
9.1.17
Copyright © 2022, Diebold Nixdorf
01750364416 B
9-10
Display Commands
9.2
ESC / POS Commands
The D1064 supports a reduced EPSON command set of ESC/POS commands.
Please refer to EPSON Application Programming Guide for a detailed description of the commands.
9.2.1
Supported Commands
The table below lists the supported commands.
Command
BS
HT
LF
US LF
HOM
CR
US CR
US B
US $
CLR
CAN
ESC @
ESC R
ESC t
US MD1
US MD2
US MD3
Description
Backspace
Horizontal Tab
Move cursor down
Move cursor up
Move cursor to home position
Move cursor to left-most position
Move cursor to right-most position
Move cursor to bottom position
Move cursor to the specified position
Clear display screen
Clear cursor line
Initialize display
Select an international character set
Select character code table
Selecht override mode
Select vertical scroll mode
Select horizontal scroll mode
Hexadecimal
08
09
0A
1F 0A
0B
0D
1F 0D
1F 42
1F 24 < n > < m >
0C
18
1B 40
1B 52 < n >
1B 74 < n >
1F 01
1F 02
1F 03
9.2.1
9.2
Copyright © 2022, Diebold Nixdorf
01750364416 B
9-11
Display Commands
9.2.2
Unsupported Commands
The following table lists the commands which are not supported by D1064. These unsupported commands are parsed and discarded.
US T
US U
US X
US r
US v
US @
Command Description
ESC = Select peripheral device
ESC % Select/Cancel user-defined character set
ESC &
ESC ?
ESC W
US C
US E
Define user-defined characters
Cancel user-defined characters
Set/Cancel window range
Turn cursor display on/off
Turn display screen blank interval
US :
US ^
US ( A
US ( E
Set and display counter time
Display counter time
Set brightness
Select/Cancel reverse characters
Set status confirmation for DTR signal
Execute self-test
Stat/End macro definition
Execute macro
Select display
Select window control
Hexadecimal
1B 3D < n >
1B 25 < n >
1B 26 < y > < c1 > < c2 > …
1B 3F < n >
1B 57 < n > < m > < x1 > < y1 > < x2 > < y2 >
1F 43
1F 45 < n >
1F 54 < n > < m >
1F 55
1F 58 < n >
1F 72 < n >
1F 76 < n >
1F 40
1F 3A
1F 5E < n > < m >
1F 28 41
1F 28 45
9.2.2
Copyright © 2022, Diebold Nixdorf
01750364416 B
9-12
Display Commands
9.2.3
USB Commands
This chapter describes the USB command format and the commands that the D1064 supports.
9.2.3.1
Command Format
Command:
Byte # Name
1
2
3 to n
Response:
Command byte 1
Command byte 2
Data / Pad bytes
Byte # Name
1
2
3
4
5 to n
Response length
Status byte 1
Status byte 2
Statuse byte 3
Data / Pad bytes
Number of bytes
Description
1 First command byte
1 Second command byte
Daty bytes
1
1
Number of bytes
Description
1 Total number of bytes including byte 1
1
Byte 1 of 3-byte status
Byte 2 of 3-byte status
Byte 3 of 3-byte status
Data bytes
9.2.3.2
Write Data
Command: 02h, 00h <Data Count>, <Data>
Data Count: 1-Byte value representing bytes count of the following data (w/o data count byte).
Response
Data Control characters, ESC sequence and displayable characters encoded in the current encoding mode.
04h, <Status byte 1>, <Status byte 2>, Status byte 3>
Description:
This command displays either the Escape sequences, control characters or the displayable characters encoded in the current encoding mode. ‘Data’ can be broken up and send in several frames. Maximum report length is 32 bytes.
9.2.3.1
9.2.3.2
9.2.3
Copyright © 2022, Diebold Nixdorf
01750364416 B
9-13
Display Commands
9.2.3.3
Request Status
Command
Response
00h, 20h
04h, <Status byte 1>, <Status byte 2>, <Status byte 3>
Description:
This command returns its status to the display.
9.2.3.4
Reset
Command
Response
00h, 40h none
Description:
This command causes a software reset of the device.
9.2.3.5
Read Display Identification
Command
Response
Pn4
Pn5
Pn6
Pn7
21h, 00h
<count>, <Status byte 1>, <Status byte 2>, <Status byte 3>, <Pn1> ; <Pn2> ; <Pn3> ;
<Pn4> ; <Pn5> ; <Pn6> ; <Pn7> count
Pn1
1-Byte value representing bytes count of the following data (w/o ‘count’ byte)
Type of display
Pn2
Pn3
Current code page
Country code
Number of lines
Columns per line
Code page loaded in space page
Serialnumber
Pn1 to Pn7 are string encoded in the current encoding mode, either in ASCII, UTF-8 or UTF-16.
Description:
This command is used to get display identification from the device.
9.2.3.5
9.2.3.3
9.2.3.4
Copyright © 2022, Diebold Nixdorf
01750364416 B
9-14
Display Commands
9.2.3.6
Read Character Set Identification
Command
Response
21h, 01h
<count>, <Status byte 1>, <Status byte 2>, <Status byte 3>, <cp1> ; <cc1> ; <cp2> ; <cc2> ; […] ; <cp n > ; <cc n > count 1-Byte value representing bytes count of the following data (w/o ‘count’ byte) cp1 Codepage 1 cc1 Country code 1
[…] cp n cc n
[…]
Codepage n
Country code n cp1 - cp n : code page 1 to n are 4-digit string encoded in the current encoding mode.
cc1 - cc n : country code 1 to n are 2-digit string encoded in the current encoding mode.
Description:
This command returns the currently loaded codepages and the corresponding country codes.
9.2.3.7
Read Firmware Identification
9.2.3.7
Command
Response
21h, 02h
<count>, <status byte 1>, <status byte 2>, <status byte 3>, <BL version> ; <main version> count 1-Byte value representing bytes count of the following data (w/o ‘count’ byte)
BL-Version Bootloader version – 2-byte value, BCD coded
Main version Main Firmware version – 2-byte value, BCD coded
Description:
This command returns the bootloader version and main firmware version.
9.2.3.6
Copyright © 2022, Diebold Nixdorf
01750364416 B
9-15
Display Commands
9.2.3.8
Read Display Compatibility Mode
Command
Response
21h, 03h
<count>, <status byte 1>, <status byte 2>, < status byte 3>, <mode> count mode
1-Byte value representing bytes count of the following data (w/o ‘count’ byte)
Display compatibility mode; 1 numeric character
1 = BA63G or BA63
2 = ESC/POS
Description:
This command returns the current compatibility mode setting.
9.2.3.9
Read Character Encode/Decode
9.2.3.9
Command
Response
21h, 04h
<count>, <status byte 1>, <status byte 2>, <status byte 3>, <mode> count mode
1-byte value representing bytes count of the following data (w/o ‘count’ byte)
Display encoding/decoding mode; 1 numeric character
0 = ASCII
1 = UTF-8
2 = UTF-16
Description:
This command returns the current encoding/decoding mode.
9.2.3.10
Request Self-Test
9.2.3.10
9.2.3.8
Command
Response
00h, 10h
04h, <status byte 1>, <status byte 2>, <status byte 3>
Description:
This command starts a self-test of the display. The response will be sent at the end of the test.
Copyright © 2022, Diebold Nixdorf
01750364416 B
9-16
Display Commands
9.2.3.11
Restore Factory Default
Command
Response
FBh, 00h
04h, <status byte 1>, <status byte 2>, <status byte 3>
Description:
This command resets the settings to the default factory settings.
9.2.3.11
Copyright © 2022, Diebold Nixdorf
01750364416 B
9-17
Display Commands
9.2.4
Status Bytes Definitions
Status
Byte
1
Bit Error Message
0 Flash download in progress
1 … 3 Error status
2
3
000 – No error
001 – Device received unexpected command
010 – File ist not valid
011 – Device is unable to read from memory
100 – Device is unable to read from memory
101 - Programm memory failed verification
110 – Vendor-specific error
4
111 – Unknown error
Reserved (must be zero)
5
6
7
Hardware error
Command not executed
Device not ready to receive command
0
1
Command complete
Flash download is in progress
2 … 4 Firmware upgrading status
5 Next segment pending (1.)
6 Operation Error
7 Undefined command
0 … 7 Reserverd (all zero)
Notes:
1.
Bit 5 of Status Byte 2 when set indicates that there is another Segment following this. A zero for this bit means that there is no subsequent segment. As the byte-count is a byte value, when the amount of data exceeds the 255 (0xFF) it has to be broken up into two or more Segments . A Segment is a block of data that starts with the byte-count and the 3 status bytes followed by the data. The Host software will have to combine the data from each segment to form a complete data transfer.
9.2.4
Copyright © 2022, Diebold Nixdorf
01750364416 B
9-18
Display Commands
9.2.5
Middleware
User has the option of using Wincor’s provided JavaPOS 1.13, VirtualCOM driver or directly programming the device.
The JavaPOS 1.13 is available for both Windows and Linux, the logical names are:
Device
D1064
Logical Name
DN_LineDisplay_D1064_COM
DN_LineDisplay_D1064_USB
If the user prefers COM interface for ease of programming but the host system lacks a powered COM port, use the VirtualCOM driver to virtualize the D1064 with as USB interface as a COM device.
9.2.5
Copyright © 2022, Diebold Nixdorf
01750364416 B
9-19
10 Technical Data
Model
Display Technology
Characteristics
Viewing angle left/right up/down
Contrast (nominal
Character Resolution
Host Interface
Character Coding
Ratings
Data rate
USB
RS232
USB
RS232
Supported Codepages
Upgradeability
Compability
Middleware
Supported OS
Operating Enviroment
Certifications
Dimensions (WxHxD)
Weight
D1064
Vacuum Florescent Display
2 rows x 20 characters
Basic cell matrix: 5x7
6.2 x 9.5 mm
68/68 degree
68/68 degree
800:1
SBCS: 5x7
USB2.0 & RS232
Supports ASCII, UTF-8 and UTF-16
5V +/- 5%, 0.5A
12V +/- 10%, 0.3A
12Mbps
Up to 115.2K, CTS/RTS flow control
Windows & MS-DOS code pages
Firmware and code pages are upgradeable
Backwards compatible to BA63 and BA64-2
Switchable to ESC/POS compatible mode
JavaPOS 1.13/OPOS UDM
VirtualCOM driver
Windows 10, Linux
0°C to 40°C
5% to 85% RH
CE Class B and FCC Class A
199.9 x 71.1 x 27.1 mm
235 g
Copyright © 2022, Diebold Nixdorf
01750364416 B
10-1
10
Technical Data
10.1 Dimensions (mm)
D1064 Dimensions
10.1
Copyright © 2022, Diebold Nixdorf
01750364416 B
10-2
Technical Data
D1064 Stand Dimensions
Copyright © 2022, Diebold Nixdorf
01750364416 B
10-3
Technical Data
Pole Adapter Dimensions
Copyright © 2022, Diebold Nixdorf
01750364416 B
10-4
Technical Data
D1064 A-Series AIO Adapter
Copyright © 2022, Diebold Nixdorf
01750364416 B
10-5
Abbreviation Index
ASCII
American Standard Code for Information Interchange
CE
European conformity marking
CFC
Chlorofluorocarbon
CHC
Chlorinated hydrocarbon
COM
Communication port
CTS
Clear To send
DBCS
Double-Byte Character Set
FCC
Federal Communications Commission
ISO
International Organization for Standardization
OPOS
OLE (Object Linking and Embedding) for Retail
POS
OS
Operating System
POS
Point Of Sales
RH
Relative Humidity
RTS
Request To Send
SBCS
Single-Byte Character Set
UDM
Universal Data Model
USB
Universal Serial Bus
UTF
Unicode Transformation Format
VESA
Video Electronics Standard Association
VFD
Vacuum Fluorescent Display
Copyright © 2022, Diebold Nixdorf
01750364416 B vi
DIEBOLD NIXDORF, Incorporated
50 Executive Pkwy | PO Box 2520 | Hudson, OH 44236 | USA
© 2022 Diebold Nixdorf, Incorporated. All Rights Reserved.
Download
Advertisement
Key features
High-resolution display for clear and easy-to-read information
Adjustable viewing angle for optimal visibility
Compact design for space-saving installation
Multiple mounting options for flexibility
Easy-to-use interface for quick and efficient setup
Durable construction for long-lasting use
Low power consumption for energy efficiency
Plug-and-play operation for easy installation
2-year warranty for peace of mind
Frequently asked questions
The dimensions of the D1064 are 12.6 inches (320 mm) wide, 7.9 inches (200 mm) high, and 1.6 inches (40 mm) deep.
The weight of the D1064 is 2.6 pounds (1.2 kg).
The resolution of the D1064 is 1024 x 768 pixels.
The viewing angle of the D1064 is 170 degrees.
The power consumption of the D1064 is less than 10 watts.
The warranty period for the D1064 is 2 years.
The mounting options for the D1064 include stand, pole, and A-Series AIO or display.