Schneider Electric Merten inserts- Universal LED Dimmer module User Guide

Universal LED dimmer moduleArt. no. CCT99100© Schneider-Electric 2014EAV56166-0208/16 en The dimmer module automatically recognises the connected load. It is overload-proof, short-circuit-proof, protected from overheating and it has a soft-start function. Universal LED dimmer module Wiring the dimmer module L N The memory function allows the dimmer module to memorise the most recently set brightness value and retrieve it again. You can set the dimming range and adjust the operating mode (from trailing edge phase to leading edge phase). Operating instructions L 1 L ½ CAUTION The dimmer may be damaged! • Always operate the dimmer according to the technical data provided. • Connected dimmers may be damaged if you connect a combination of loads (inductive and capacitive) at the same time. Art. no. CCT99100 Installing the dimmer module • The dimmer is designed for sinusoidal mains voltages. • If transformers are used, only connect dimmable transformers to the dimmer. Accessories • Dimming socket outlets is prohibited. The risk of overload and connecting unsuitable dimmers is too high. Complete the universal LED dimmer module with: • Mechanical retractive push-buttons in design series of free choice • If a terminal is used for looping, the insert must be protected with a 10 A circuit breaker. For your safety ¼ Setting the dimmer module DANGER Risk of serious damage to property and personal injury, e.g. from fire or electric shock, due to incorrect electrical installation. Safe electrical installation can only be ensured if the person in question can prove basic knowledge in the following areas: Connections, displays and operating elements ¼ A c • Connecting to installation networks B • Connecting several electrical devices DANGER Risk of fatal injury from electric shock. When setting the operating mode or operating the dimmer module by means of the installed programming push-button, pay attention to particular rules for live working. Only press the programming push-button with an insulated pin, for example an insulated screwdriver that meets the requirements of EN 60900. • Laying electric cables These skills and experience are normally only possessed by skilled professionals who are trained in the field of electrical installation technology. If these minimum requirements are not met or are disregarded in any way, you will be solely liable for any damage to property or personal injury. Getting to know the dimmer module The universal LED dimmer module (referred to below as dimmer module) is suitable for installation in a deep installation box. The dimmer module is controlled with mechanical push-buttons in parallel operation. Ohmic, inductive or capacitive loads can be switched or dimmed with it: L A Programming push-button B Status LED C Function potentiometer Setting the dimming range The dimming range of the dimmer module can be adjusted. | Depending on the dimming range of the lamp, malfunctions may occur for values near the maximum and minimum brightness. (Refer to the chapter "What should I do if there is a problem?") Mounting the dimmer module | Do not connect more than three dimmer modules to one cable with 16 A fuse protection. | If you do not install the dimmer module in a single, standard flush mounting box, the maximum permissible load is reduced due to the restricted heat dissipation: Load reduced by When installed In cavity walls* Dimmable LED lamps Incandescent lamps (ohmic load) 230 V halogen lamps (ohmic load) Low-voltage halogen lamps with dimmable wound transformer (inductive load) Low-voltage halogen lamps with electronic transformer (capacitive load) 25% Several installed together in combination* 30% In 1-gang or 2-gang surface-mounted housing 50% In 3-gang surface-mounted housing * If more than one factor applies, add the load reductions together. EAV56166-02 08/16 ¼ DANGER Risk of death from electric shock. The outputs may carry an electrical current even when the device is switched off. Always disconnect the fuse in the incoming circuit from the supply before working on connected loads. 1 L Setting the minimum and maximum brightness RL(LED) 1 2 MIN Switching the operating mode to RL LED mode RESET MAX RL(LED) 1 < 0,5 sec 3 2 MIN Connecting the mechanical pushbutton RESET MAX ¼ < 0,5 sec 4 3 DANGER Risk of death from electric shock. However the device is turned off there might be full voltage at the output. Always turn the device in the status of voltage free before starting with work. 4 2 sec 3x < 0,5 sec 3x < 0,5 sec > 0,5 sec 3 sec The circuit breaker is switched on. (Live working!) 5 8 sec 1 Make sure that the connected load is turned off with the programming push-button. 2 sec 2 Set the function potentiometer to RL(LED). 1 Make sure that the connected load is turned off with the programming push-button. 2 Set the function potentiometer to MIN or MAX. 3 Press the programming push-button shortly 3 times. The dimmer module is in programming mode. The status LED flashes according to the operating mode (see "Displaying the operating mode"). 4 According to selection in step 2: Set the minimum or maximum lamp brightness by holding down the programming push-button. 5 The new value will be automatically saved after 8 seconds if the programming push-button is not pressed again during this time. The connected load is automatically switched off. The status LED lights up for 2 seconds. The default setting of the dimmer module is the RC mode. The dimmer module automatically recognises inductive load (RL mode). However, not all lamps will work proper with the automatically recognised load. In this case you can switch the operating mode to RL LED. | In the operating mode "leading edge phase for LED lamps" (RL LED mode), LED lamps can only be connected at up to 10% of the maximum permissible dimmer load. Resetting to default mode 2 1 x 0,5 sec = RC mode 2 x 0,5 sec = RL mode 3 x 0,5 sec = RL (LED) mode B Long press: dimming up or down 1 2 MIN RESET MAX What should I do if there is a problem? The dimmer dims down regularly during operation and cannot be dimmed up again. • Allow the dimmer to cool down and reduce the connected load. 3 3x < 0,5 sec The circuit breaker is switched on. (Live working!) 1 Make sure that the connected load is turned off with the programming push-button. 2 Press the programming push-button shortly 3 times. The status LED displays the current operating mode. It flashes briefly 1-3 times depending on the operating mode. The load cannot be switched back on. 4 2 sec • Allow the dimmer to cool down and reduce the connected load. • Rectify any possible short circuits. 3x < 0,5 sec < 0,5 sec B A Short press: switching on or off < 0,5 sec Displaying the operating mode A The operating mode is switched to "leading edge phase for LED lamps" (RL LED mode). RL(LED) Operating mode 1 4 Press the programming push-button for 3 seconds. The status LED lights up for 2 seconds. Operating the dimmer module • Renew defective loads. 3 sec The circuit breaker is switched on. (Live working!) 1 Make sure that the connected load is turned off with the programming push-button. 2 Set the function potentiometer to RESET. 3 Press the programming push-button shortly 3 times. The dimmer module is in programming mode. The status LED flashes according to the operating mode (see "Displaying the operating mode"). 4 Press the programming push-button for 3 seconds. The status LED lights up for 2 seconds. The operating mode is switched to "trailing edge phase" (RC mode) and the minimum/maximum brightness value is reset. The load is dimmed to the minimum brightness. • The circuit is overloaded. -> Reduce load. • The circuit falls short of the minimum load. -> Increase load. • Dimming range is incorrect. -> Reduce maximum brightness value. The load flickers at minimum brightness. The circuit falls short of the minimum possible brightness value. • Increase minimum brightness value (set dimming range). The load flickers continuously. Incorrect operating mode set. • Switch operating mode to "leading edge phase for LED lamps" (RL LED mode). • Alternatively, reset operating mode to default. The load can only be dimmed slightly. • Set dimming range. • Switch operating mode to "leading edge phase for LED lamps" (RL LED mode). • Alternatively, reset operating mode to default and set dimming range again. EAV56166-02 08/16 The circuit breaker is switched on. (Live working.) 3 Press the programming push-button shortly 3 times. The dimmer module is in programming mode. The status LED flashes according to the operating mode (see "Displaying the operating mode"). Technical data Nominal voltage: Switching capacity: LED lamps (RC mode): LED lamps (RL LED mode): Incandescent lamps: 230 V halogen lamps: LV halogen lamps with dimmable wound transformer: LV halogen lamps with electronic transformer: Neutral conductor: Connecting terminals: Extension connection: Total cable sections: Fuse protection: Dimensions (HxWxD): Properties: AC 230 V ~, 50 Hz 4-100 VA 4-20 VA 5-200 W 5-150 W 5-200 VA 5-200 VA not required screw terminals for max. 2.5 mm2 mechanical push-buttons max. 20 m for 3-wire NYM cable 16 A circuit breaker 44.5 x 39.5 x 20 mm • Short-circuit-proof • Overload-proof • Soft start • Resistant to overheating • Automatic load detection Dimmer tool Schneider Electric has tested numerous dimmable LED and energy saving lamps. The dimmer tool provides information on dimmable lamps and the minimum and maximum number of individual lamp models. http://schneider-electric.dimmer-test.com Dispose of the device separately from household waste at an official collection point. Professional recycling protects people and the environment against potential negative effects. Schneider Electric Industries SAS If you have technical questions, please contact the Customer Care Centre in your country. EAV56166-02 08/16 schneider-electric.com/contact
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
Download PDF
advertisement