ARGUS 180 flush-mounted sensor module© Merten2005V5781-561-0002/08
GB
Connections, displays and operating
elements
A
ARGUS 180 flush-mounted sensor
module
40
1 Feed connecting cables through the adjustment
ring and wire the relay or electronic switch insertas
described in the appropriate manual.
A
80
H
C
3
20
Operating instructions
B
How to install the sensor module
8
min
1s
B
C
D
A Setting the switching duration
B Setting the detection brightness
E
C Setting the sensitivity
ARGUS 180 flush-mounted sensor
module
Art. no. MTN5781..
F
Selecting the installation site
G
• Only mount the sensor module in positions which allow the best possible surveillance of the required area.
For your safety
Risk of fatal injury from electrical current.
All work carried out on the unit may only be performed by skilled electricians. Observe the regulations valid in the country of use.
Getting to know the sensor module
The ARGUS 180 flush-mounted sensor module from the
AQUADESIGN range (reffered to below as the sensor
module) is a movement detector for flush mounting indoors, and can also be used in damp areas thanks to its
waterproof housing. The sensor module detects moving
sources of heat, such as people. Adjustable range: approx. 2.5–8 m / Angle of coverage: 180°. The sensor
module is plugged onto a switch insert which switches
any connected loads when it detects a movement. It is
easy to replace light switches and use the ARGUS instead
• Observe the area of detection: Install the sensor module on the wall at a height of 1-1.5 metres above the
floor. Any mounting height which deviates from this will
affect the range.
• Install the sensor module laterally with respect to the
direction of movement so that the beam paths are intersected as vertically as possible.
8
1
2
3
4
5
6
7
The switch insert in question switches any connected
loads whenever it detects a movement.
In addition, you also need an AQUADESIGN frame with/
without screw fitting.
Relay or electronic switch insert
D
Retaining ring
E
Gasket
F
Sensor module
G
Design frame
H
Sponge rubber
2 Push the adjustment ring onto the relay or electronic
switch insert from behind and install the switch box
in such a way that the quadruple plug connector is
at the bottom.
3 Place the retaining frame onto the switch insert, insert the gasket and then carefully press the sensor
module onto the switch insert.
7
6
5
4
3
2
UP
1
0
1
2
3
4
5
8
8m
7
The sensor module is plugged onto an electronic switch
insert (art. no. MTN576799, for ohmic loads) or onto a relay switch insert (art. no. MTN576897, for ohmic and
complex loads such as incandescent lamps, fluorescent
lamps, energy-saving lamps, LV halogen lamps).
Adjustment ring
C
8
6
Necessary accessories
B
4 Place the sponge rubber onto the retaining frame.
1m
m0
Switch bx (flush-mounted box)
8m
¼
DANGER
A
8m
• Movement detectors can detect all objects that radiate
heat. This could be people, but also small animals
(dogs, cats etc.), open fires or window panes which
have been heated by the sun. For this reason, you
should select an installation site that will not result in
such unwanted heat sources being detected.
• The sensor module is not suitable for use as a component of an alarm system since the device is supplied
from the mains and will switch the connected detectors whenever the mains supply fails and is established again, regardless of whether or not a movement
is detected. This could in turn trigger the alarm function (false alarm).
½
CAUTION
Benting of the pins.
The contact pins on the rear of the sensor module
can become bent if angled excerssively. Therefore always plug the sensor module in as straight
as possible.
You may fix the retaining frame to the wall by using suitable screws.
5 Press the design frame onto the retaining frame so
that it clicks into place.
6 For design frames with screw fitting: Screw the design frame with the retaining frame.
V5781-561-00 02/08
AQUADESIGN
How to set up the sensor module
How to remove the sensor module
In order to ensure optimal functioning of the sensor module, you must set it after installation.
1 Use a screwdriver to remove the design frame
(which is either clicked or screwed into place) from
the retaining frame.
1 Pull the sensor module with frame forwards from the
switch insert.
2 Set the switching duration to 1 second and set the
detection brightness to day and night operation.
3 Carefully push the sensor module with frame back
onto the switch insert.
4 Activate the load which is to be switched.
5 Approach the area of detection from several different angles. If necessary, alter the sensitivity until the
movement detector switches the load as required.
When everything is working as it should:
6 Set the switching duration and the detection brightness as desired.
2 Unscrew the retaining frame from the wall if necessary and carefully remove the sensor module from
the switch insert in a straight, forward motion.
7 Mount the sensor module and frame again.
You can set the switching duration, detection brightness
and sensitivity on the rear of the device.
Setting the switching duration
You can use this to infinitely set how long the load connected to the switch insert remains switched on. When a
movement is detected by the sensor module, the load
(e.g. ceiling light) is switched on and stays switched on
until the set period has elapsed. Every time a new movement is detected, the switching duration is restarted:
• Left stop: switching duration approx. 1 second
• Right stop: switching duration approx. 8 minutes
Setting the detection brightness
Here you can infinitely set at which ambient brightness
level movements should be detected and a switching
procedure should be triggered:
• Left stop (sun symbol): Day and night operation (approx. 1000 lux), all movements in the area of detection
will be detected.
• Right stop (moon symbol): Night operation (approx.
5 lux), movements are only detected in the dark.
Setting the sensitivity
You can use this to infinitely set the range up to which the
sensor module should be able to detect movements:
• Left stop: Low sensitivity, movements up to a distance
of approx. 2.5 m will be detected.
• Right stop: Maximum sensitivity, movements up to a
distance of approx. 8 m will be detected.
Whenever the power supply has failed and been re-established, the connected load switches for the duration
of the selected switching time.
CAUTION
Benting of the pins
The contact pins on the rear of the sensor module
can become bent if angled excessively. Therefore
always pull the sensor module out as straight as
possible.
How to handle faults
The connected load will not be switched on.
Check the possible sources of error:
• Connected load not connected, wrongly connected or
switched off.
• Sensitivity set too low.
• Detection brightness set incorrectly.
• Heat source not in the area of detection of the sensor
module.
• In the case of a sensor module with switch, the switch
is set to 0 (Off).
• Fuse defective (for information on how to change the
fuse, see the manual of the switch insert).
The connected load is switched on permanently.
• It could be that the switching duration is set too high.
The sensor module constantly detects new movements and restarts the switching duration. For this reason, you should stay out of the area of detection for at
least 10 minutes.
• In the case of a sensor module with switch, it could be
that the switch is set to 1 (On).
Technical data
Range:
Area of detection:
Switching duration:
Detection brightness:
Type of protection:
min. approx. 2,5 m,
max. approx. 8 m, infinitely
adjustable
180°
1 s - 8 min, infinitely adjustable
approx. 5 - 1000 Lux,
infinitely adjustable
IP 44 (Splash proofed)
Schneider Electric Industries SAS
If you have technical questions, please contact the Customer Care Center in your country.
www.schneider-electric.com
This product must be installed, connected and used in
compliance with prevailing standards and/or installation
regulations. As standards, specifications and designs
develop from time to time, always ask for confirmation of
the information given in this publication.
V5781-561-00 02/08