Schneider Electric InRow Direct Expansion Air Conditioners Specifications

InRow® Direct Expansion Air Conditioners ACRD100, ACRD200, ACRD600, and ACRD600P Series Technical Specifications Up to 42kW 990-5801C-001 Release Date: 10/2019 www.schneider-electric.com Legal Information The Schneider Electric brand and any trademarks of Schneider Electric SE and its subsidiaries referred to in this guide are the property of Schneider Electric SE or its subsidiaries. All other brands may be trademarks of their respective owners. This guide and its content are protected under applicable copyright laws and furnished for informational use only. No part of this guide may be reproduced or transmitted in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise), for any purpose, without the prior written permission of Schneider Electric. Schneider Electric does not grant any right or license for commercial use of the guide or its content, except for a non-exclusive and personal license to consult it on an "as is" basis. Schneider Electric products and equipment should be installed, operated, serviced, and maintained only by qualified personnel. As standards, specifications, and designs change from time to time, information contained in this guide may be subject to change without notice. To the extent permitted by applicable law, no responsibility or liability is assumed by Schneider Electric and its subsidiaries for any errors or omissions in the informational content of this material or consequences arising out of or resulting from the use of the information contained herein. ACRD100, ACRD200, ACRD600, and ACRD600P Series Table of Contents Technical Data .............................................................................................5 Model Identification.....................................................................................5 Overview ...................................................................................................6 Capacities ............................................................................................6 Room Air Distribution ............................................................................6 Compliance Approval ............................................................................7 Working Conditions and Environmental Limits.........................................8 Scalable Solution for Critical Environments...................................................9 InRow Advantages................................................................................9 Scalable for High Density ......................................................................9 Standard Features and Options .................................................................10 Standard Features ..............................................................................10 Optional Features ...............................................................................13 Microprocessor Controller .........................................................................14 ACRD100 and ACRD200 Series ..........................................................14 ACRD600 and ACRD600P Series ........................................................15 Microprocessor Controller....................................................................15 Open Architecture...............................................................................15 Control Type.......................................................................................15 Functions ...........................................................................................16 Logging..............................................................................................16 Control ...............................................................................................16 Alarms ...............................................................................................16 Component Identification ..........................................................................19 External Components..........................................................................19 Internal Components...........................................................................21 Electrical Panels .................................................................................27 Performance Specifications.......................................................................33 Net Cooling Capacity ..........................................................................33 General Data ......................................................................................41 Altitude Correction Factors ..................................................................45 Electrical Data ....................................................................................46 Sound Data ........................................................................................47 Dimensions and Weights...........................................................................48 ACRD100 and ACRD200 Series ..........................................................48 ACRD600 and ACRD600P Series ........................................................49 Piping and Electrical Access Locations .................................................51 ACRD600 and ACRD600P Series..............................................................55 Water-Cooled Bottom Piping (ACRD200 Series) .........................................56 Glycol-Cooled Bottom Piping (ACRD200 Series).........................................57 Outdoor Heat Exchanger Data ...............................................................58 Mechanical Data.......................................................................................58 Air-Cooled Condensers (ACRD100 Series)...........................................58 Air-Cooled Condensers (ACRD600 Series)...........................................59 Fluid Coolers (ACRD200 Series)..........................................................60 Electrical Data ..........................................................................................61 Air-Cooled Condensers (ACRD100 Series)...........................................61 Air-Cooled Condensers (ACRD600 Series)...........................................61 990-5801C-001 3 ACRD100, ACRD200, ACRD600, and ACRD600P Series Fluid Coolers (ACRD200 Series)..........................................................62 Dimensions ..............................................................................................62 4 990-5801C-001 Technical Data ACRD100, ACRD200, ACRD600, and ACRD600P Series Technical Data Model Identification ACRD100 Series and ACRD200 Series—300 mm Units The model number can be found on the outside of the shipping crate and on the name plate located on the unit as shown. Use the table below to verify that the equipment is the right type and voltage. REAR na4402b NAME PLATE Model Range of Capacity Heat Rejection Voltage/Phase/ Frequency Humidifier/Reheat Air Pattern ACRD100 Up to 10 kW Air-cooled 208-240/1~/60 Hz None Back to front ACRD101 Up to 10 kW Air-cooled 220-240/1~/50 Hz None Back to front ACRD200 Up to 10 kW Fluid-cooled 208-240/1~/60 Hz None Back to front ACRD201 Up to 10 kW Fluid-cooled 220-240/1~/50 Hz None Back to front ACRD600 and ACRD600P Series—600 mm Units na5809a NAMEPLATE The model number can be found on the outside of the shipping crate and on the nameplate located inside the equipment as shown. Use the table below to verify that the equipment is the correct size and voltage. Range of Capacity Heat Rejection Voltage Frequency Reheat Humidifier Air Pattern ACRD600 Up to 42 kW Air-cooled 200–240 50/60 Hz N/A N/A Rear to front ACRD601 Up to 42 kW Air-cooled 460–480 60 Hz N/A N/A Rear to front ACRD602 Up to 42 kW Air-cooled 380–415 50/60 Hz N/A N/A Rear to front ACRD600P Up to 42 kW Air-cooled 200–240 50/60 Hz Electric Steam canister (replaceable) Rear to front ACRD601P Up to 42 kW Air-cooled 460–480 60 Hz Electric Steam canister (replaceable) Rear to front ACRD602P Up to 42 kW Air-cooled 380–415 50/60 Hz Electric Steam canister (replaceable) Rear to front SKU 990-5801C-001 5 ACRD100, ACRD200, ACRD600, and ACRD600P Series Technical Data Overview This modular, row-based computer room cooling system offers efficient, predictable, and economical cooling for a variety of spaces. Critical environmental requirements now reach far beyond the confines of the traditional data center or computer room to encompass a larger suite of applications, referred to as technology rooms. Critical environment applications include the following: • Computer rooms • Telecommunication facilities • Clean rooms • Power equipment • Medical equipment rooms • LAN/WAN environments A worldwide network by Schneider Electric representatives is fully qualified to provide engineering, sales, installation, and service for our products. Capacities InRow® Direct Expansion (DX) units are available in two sizes (300 mm and 600 mm) with nominal capacities ranging from 2–10 kW (300 mm) and 8–42 kW (600 mm). Room Air Distribution Row-based systems are placed in line with rack enclosures. At least one system is used per hot aisle. Air is drawn in through the rear of the system, cooled, and discharged into the cold aisle, thereby neutralizing the sensible heating effects of the data processing equipment. InRow DX products deliver high volumes of airflow to eliminate hot spots in densely populated environments. Configuration: 6 • Air-cooled • Fluid-cooled 990-5801C-001 Technical Data ACRD100, ACRD200, ACRD600, and ACRD600P Series Compliance Approval Agency UL and cUL ACRD100 ACRD101 ACRD200 ACRD201 ACRD600 X X X X X RCM X X CE X X EAC X CMIM Agency X X ACRD600P ACRD601 ACRD601P ACRD602 ACRD602P X X X X X RCM X X CE X X X X X X UL and cUL EAC CMIM 990-5801C-001 X X X 7 ACRD100, ACRD200, ACRD600, and ACRD600P Series Technical Data Working Conditions and Environmental Limits InRow DX units have a minimum heat load to ensure proper operation. Failure to operate the unit with at least the minimum load will result in one or more of the following conditions: • Decreased operating efficiency • Equipment on/off cycling • Inadequate dehumidification • Increased wear and tear caused by frequent on/off cycles • Decreased group control effectiveness • Potential increase in cost of ownership Limit Working Conditions Models Power Supply Minimum Recommended Load 8 ACRD600 ACRD600P ACRD601 ACRD601P ACRD602 ACRD602P 200–240 V 3 Phase 50/60 Hz 460–480 V 3 Phase 60 Hz 380–415 V 3 Phase 50/60 Hz 8 kW (27,296 BTU/hr) 990-5801C-001 Technical Data ACRD100, ACRD200, ACRD600, and ACRD600P Series Scalable Solution for Critical Environments InRow Advantages na5859a The row-based solution improves energy efficiency and cooling ability in a number of ways. First, the InRow DX unit draws air directly from the hot aisle, allowing the InRow DX unit to take advantage of higher heat transfer efficiency due to higher temperature differences. It can then discharge room-temperature air directly in front of the servers it is cooling. Placing the unit in the row enables the unit to operate at higher return and supply air temperatures, yielding 100% sensible capacity. This significantly reduces the need for humidification. HOT AISLE Scalable for High Density The predictable performance of the row-based architecture makes it well-suited for high density applications. The focus on heat removal instead of cold-air delivery is the key to making this approach scalable. The modular design of the InRow DX unit allows it to be easily added in the row as the demand for cooling increases. The additional benefit of the row-based architecture is the ability to add hot-aisle containment. Containing the hot aisle further reduces any chance of hot and cold air streams mixing. This provides ultimate predictability and allows the cooling capacity to be matched to the IT heat load. 990-5801C-001 9 ACRD100, ACRD200, ACRD600, and ACRD600P Series Technical Data Standard Features and Options Standard Features • • • • All series ◦ Variable-speed fans ◦ Standby input ◦ Common alarm output ◦ Internal condensate pump ◦ Top or bottom piping ◦ Network Management Card (NMC) ◦ Remote temperature sensors ◦ Microprocessor controller ◦ Insulated cabinet ACRD100 series and ACRD200 series only ◦ Washable filter ◦ Condensate management with dual floats ◦ Condensate pump ◦ Scroll compressor ◦ Hot gas bypass ◦ 2-way/3-way floating point valve (ACRD200 series only) ◦ Liquid line solenoid valve (ACRD100 series only) ◦ Isolation ball valves ACRD600 and ACRD600P series only ◦ Backward inclined impeller ◦ Pleated 100-mm (4-in.) filter ◦ Condensate management with a dual-position float ◦ Scroll compressor with VFD control ◦ Liquid line solenoid valve ◦ Pipe adapters ◦ Electric reheat (ACRD600P series only) ◦ Humidifier (ACRD600P series only) Accessories ◦ Cable leak detector ◦ Joining kit—InRow to NetShelter® VX rack ◦ NetShelter SX 42-U to 48-U height adapters ◦ NetShelter VX 42-U height adapters ◦ Bridge trough power cable shield ◦ Data cable bridge partition ◦ Fluid cooler ◦ Condenser ◦ Aisle/rack containment Cabinet The frame is constructed of 16-gauge formed steel for maximum strength. The cabinet is serviceable from the front and rear. All exterior panels and corner posts on the frame are powder coated for durability and an attractive finish. The front and rear exterior panels are constructed of 18 gauge perforated steel with 80% 10 990-5801C-001 Technical Data ACRD100, ACRD200, ACRD600, and ACRD600P Series open free area. All panels, which include a key latch for safety and security, allow easy access and removal. Insulation (ACRD100 and ACRD200 series only) is 80.1 kg/m3 (5 lb/ft3) density and complies with ASTM E84 rating of 25/50. Condensate Pump • ACRD100 and ACRD200 series: A condensate pump is factory wired and piped internally to the condensate drain pan. The pump is capable of pumping 34 l/h (9 g/hr) against head pressures of up to 50 ft (15.2 m) of total run. Of that run, 16 ft (4.9 m) can be vertical lift as measured from floor level. Dual floats are included with the unit. One float is used for condensate pump control, and the other float generates a condensate pump failure alarm. The InRow RD unit can be set to either continue running in an alarm condition or shut down to prevent condensate pan overflow. • ACRD600 and ACRD600P series: A condensate pump is factory wired and piped internally to the condensate drain pan. Within the condensate pump, there is a dual position float. The first position is used for condensate pump control and the other float generates a condensate pump failure alarm to prevent condensate pan overflow. Counterflow Cooling Coil/Condensate Pan Designed for high-sensible heat ratios, the coil is constructed with copper tubes, raised-lance-type aluminum fins, and 18-gauge galvanized steel end plates. Coil headers are equipped with anti-drip shields in the event of condensation. The condensate pan is thermal formed non-ferrous material, and is sloped for positive drainage to provide higher indoor air quality. Electric Reheat (ACRD600P Series Only) Electric reheat elements are low watt density, wired for three-phase and loaded equally on all three phases, and electrically and thermally protected by both automatic and manual reset thermal cut outs. Reheat elements are stainless steel, fin tubular construction. Filters Filtration of conditioned air is extremely vital to maintaining the clean, particle-free environment required by electrical equipment. Filters are easily replaceable from the rear of the unit. The ACRD100 and 200 series systems use greater-than 20% efficiency ASHRAE 52.1, 12.7 mm (1/2 in.) washable filters that meet HF-1 standards for electronics (MERV 1 per ASHRAE 52.2). The ACRD600 and ACRD600P series system uses a 30% efficient, 102 mm (4 in.), deep loading, pleated filter (MERV 8 per ASHRAE 52.2, EN779 G4). 990-5801C-001 11 ACRD100, ACRD200, ACRD600, and ACRD600P Series Technical Data Humidifier (ACRD600P Series Only) The humidifier is a self-contained, steam-generating type, factory piped and wired, with a disposable cylinder and an automatic solid state control circuit. Humidifier canisters are replaceable. The humidifier controller communicates directly to the microprocessor controller and provides complete status and control at the operator interface. Joining Kit—InRow/NetShelter SX Joining kits made of 16-gauge steel enable joining the InRow unit to NetShelter enclosures. Network Management Card The Network Management Card (NMC) allows communication with the local area network (LAN). In addition, the NMC permits multi-level access to monitoring, control, and event notification features over the building network. Pipe Adapters (ACRD600 and ACRD600P Series Only) Standard pipe connections are 31.75 mm (1 1/4 in.) 12 UNF female threaded ring seal (manufactured in accordance with ANSI B1.1). The adapter converts the threaded ring seal to a sweat adapter. Remote Temperature Sensors To control the cooling unit based on rack inlet temperature, remote temperature sensors are provided. The ACRD100 and ACRD200 series units come equipped with one temperature sensor, and the ACRD600 and ACRD600P series units come equipped with three. These sensors measure temperature at a point 4 m (13 ft) from the connection inside the InRow DX unit. These sensors are used for remote placement in the field on an adjacent IT rack. Shutdown Input/Alarm Output The unit provides one field connection input for remote shutdown and one field connection alarm output. Selectable Top or Bottom Piping Connections The cooling unit includes both top and bottom piping connections. All ACRD100, ACRD600, and ACRD600P series connections use threaded ring seals for ease of installation and service. The ACRD200 series uses union connectors. Variable-Speed Fans Each unit is equipped with variable speed fans to allow for varying heat loads. In order to provide uniform airflow over the cooling coil, the fans provide a drawthrough air pattern. The ACRD100 and ACRD200 series units are equipped with six direct-drive fan modules. These fans are easily replaceable while the unit is in operation. The ACRD600 and ACRD600P series is equipped with two backward inclined, direct drive fans. 12 990-5801C-001 Technical Data ACRD100, ACRD200, ACRD600, and ACRD600P Series Optional Features Aisle Containment This containment solution isolates pods (two rows of InRow cooling units sharing a common aisle) from the whole IT environment, increasing cooling efficiency at any density. Cable Water Detector A leak detection cable is placed on the floor or sub-floor around all possible leak sources. If water or other conductive liquids contact the cable anywhere along its length, the microprocessor controller announces the leak visually, audibly, and across the network. The 6.1-m (20-ft) cable may be cascaded to make custom lengths up to 24.4 m (80 ft). Data Partition Overhead cable distribution between adjacent NetShelter racks allows for removal of the InRow DX units without disrupting overhead cabling. Filters Electrical equipment requires clean, particle-free air, thus making air filtration extremely important. As an optional feature, higher efficiency filters can be purchased for the InRow DX units. The Height Adapters To match height of the InRow DX cooling units to various rack heights, height adapters are available for NetShelter 42-U VX and 48-U SX racks. Network Cable Various lengths of network cable are available to ship with your cooling system. The network cable is used to interconnect multiple units in a redundant group, as well as to connect the Network Management Card to your LAN. Power Trough Overhead power distribution between adjacent NetShelter racks allows for removal of the InRow DX cooling units without disrupting overhead power cabling. Rack Air Containment This containment solution isolates the airflow of InRow cooling units from the whole IT environment, increasing efficiency while allowing for high density deployment. Seismic Latch Users must obtain and install this latch kit for deployments that require seismic certification (ACRD100 and ACRD200 series only). 990-5801C-001 13 ACRD100, ACRD200, ACRD600, and ACRD600P Series Technical Data Microprocessor Controller ACRD100 and ACRD200 Series Display Interface Status ESC Check Log ? Warning na1582a Critical Item 14 Description Function Critical alarm LED (red) When illuminated, a critical alarm condition exists that requires your immediate attention. Warning alarm LED (yellow) When illuminated, a warning alarm condition exists. Failure to correct this condition could cause a critical alarm. Check log LED (yellow) When illuminated, at least one new event has been logged since the last time the log was checked. Only events that pertain to the operation of the cooling unit will activate this LED. Check log LED (yellow) When illuminated, the cooling unit is receiving electrical power. When the LED is flashing, the cooling unit is downloading firmware for the controller. This may take a few minutes. Liquid crystal display (LCD) View alarms, status data, context-sensitive help, and modify configurable items. Up and down arrow keys Select menu items and access information. ESC key Return to previous screen or cancel current operation. Enter key Open menu items and input changes to the cooling unit settings. Help key Display context-sensitive help. Press the help key for information about each option on the screen and for instructions on performing the tasks. 990-5801C-001 Technical Data ACRD100, ACRD200, ACRD600, and ACRD600P Series ACRD600 and ACRD600P Series Display Interface Display Reset 10/100 USB Console Item na4820a Micro SD Service Port Description Function LCD Display 4.3-inch touch-screen color display Power LED The cooling unit is powered when the LED is illuminated. Unit firmware is updating when LED is blinking. Check Log LED When this LED is illuminated, a new entry has been made to the event log. Alarm LED Displays current alarm condition of unit. Status LED Displays current network management card status. Display Reset button Resets the display microprocessor. This has no effect on the air conditioner controller. Link-RX/TX (10/100) LED Displays current network link status. Micro SD card slot Memory card expansion slot. Service port USB-B port used only by service personnel. USB-A port Supports firmware upgrades. Serial Configuration port Connects the display to a local computer to configure initial network settings or access the command line interface (CLI). Microprocessor Controller The microprocessor controller is standard on each system. The easy-to-use display allows the operator to select options from the device menu-driven interface to control and monitor the connected air conditioning system. Open Architecture The InRow Direct Expansion protocol is open for integration with all building management systems. Communication interface on the system can be MODBUS RS485 or Ethernet. Control Type The controller uses proportional/integral/derivative (PID), a time-proven precision environmental control method. This allows for custom tuning of control variables to achieve desired system response. 990-5801C-001 15 ACRD100, ACRD200, ACRD600, and ACRD600P Series Technical Data Functions • Supply and return air conditions • Operational mode control • Event logging • Alarms • Redundant group control • Fan speed adjustment • Input/Output module programming Logging The event log keeps a record of all alarms and events. Each event log contains a time/date stamp. The controller also displays run time, in hours, for major components (air filters, fans, and condensate pump, as well as humidifier, heater, and compressor for the air-cooled unit). Control ACRD100/ACRD200 Series The back-lit, four-line by twenty-character display is password configurable. ACRD600 and ACRD600P Series The touch-screen LCD display interface is protected by a configurable password and provides access to information and settings for the unit. • Supply Temperature Setpoint: 15.0–30.2°C (59.0–86.4°F) • Cool Setpoint: 18.0–32.2°C (64.4–90.0°F) • Rack Inlet High Temperature Threshold: 10.0–65.6°C (50.0–150.1°F) • Supply Air High Temperature Threshold: 10.0–65.6°C (50.0–150.1°F) • Return Air High Temperature Threshold: 10.0–65.6°C (50.0–150.1°F) Alarms The microprocessor controller shall activate a visible and audible alarm in the following occurrences: All Series 16 • Cool fail • Air filter clogged • Return air sensor fault • Supply air sensor fault • Rack temperature sensor fault • High discharge pressure • Low suction pressure • Fan fault • Water detected (if optional leak detector used) • Check condensate management system • Air filter run hours violation • Group communication fault 990-5801C-001 Technical Data ACRD100, ACRD200, ACRD600, and ACRD600P Series • Supply air high temperature violation • Return air high temperature violation • Filter DP sensor failure • Suction pressure sensor failure • Discharge pressure sensor failure • Persistent high discharge pressure fault • Rack inlet temperature high violation • External communication fault • Internal communication fault • On standby input contact fault • A-link isolation relay fault ACRD100 Series and ACRD200 Series only • Condensate pan full • Upper fan power supply fault • Lower fan power supply fault • Suction temperature sensor failure • Persistent low suction pressure fault • Factory configuration not completed • Liquid refrigerant sensor failure ACRD200 Series Only • Condenser fluid valve actuator fault • Outdoor heat exchanger (OHE) fault ACRD600 and ACRD600P Series Only • Compressor drive communication fault • Compressor drive fault • Compressor run hours violation • Condensate pump run hours violation • Fan run hours violation • Idle mode active • High pressure switch active • Compressor high pressure • Supply humidity sensor fault • High suction pressure • Excessive compressor cycling • VFD inverter overheat • Compressor drive locked ACRD600P Series Only 990-5801C-001 • Humidifier water conductivity high violation • Humidifier fault tolerance exceeded • Humidifier low water • Humidifier excessive output reduction 17 ACRD100, ACRD200, ACRD600, and ACRD600P Series 18 • Humidifier drain fault • Humidifier cylinder full • Humidifier RS485 communication fault • Humidifier run hours violation • Humidity high/low violation • Return humidity sensor fault • Heater fault • Heater run hours exceeded Technical Data 990-5801C-001 Technical Data ACRD100, ACRD200, ACRD600, and ACRD600P Series Component Identification External Components na2625a ACRD100 and ACRD200 Series Item 990-5801C-001 Description Removable rear door Side panel latch Removable side panel Rear casters (non-swiveling) Front casters (swiveling) Adjustable leveling foot Display interface Removable front door Door lock 19 ACRD100, ACRD200, ACRD600, and ACRD600P Series Technical Data na5807a Front (ACRD60x and ACRD60xP) Item 20 Description Removable rear doors Side panel lock Removable side panel Adjustable leveling foot Caster Door handle and lock Display interface Removable front door 990-5801C-001 Technical Data ACRD100, ACRD200, ACRD600, and ACRD600P Series Internal Components na2626a Internal Components—Front Item 990-5801C-001 Description Electrical control box 1 Electrical control box 2 Temperature sensor (7 total) Condensate pan floats (2) Condensate pan Compressor Front air block panel Evaporator fans (6) Expansion valve Evaporator coil 21 ACRD100, ACRD200, ACRD600, and ACRD600P Series Technical Data na2627a Internal Components—Rear Item 22 Description Filter drier Pressure transducer (2) (located behind air block) Filter differential pressure port Air filter (2) Condensate pump (2) Electrical control box 2 Sight glass Hot gas bypass valve Liquid line shutoff solenoid Electrical control box 1 Power supply unit #2 Power supply unit #1 Service junction box (top entry shown) 990-5801C-001 Technical Data ACRD100, ACRD200, ACRD600, and ACRD600P Series na5823a Front (ACRD60x) Item 990-5801C-001 Description Condensate drain pan Electronic expansion valve Compressor Variable frequency drive for compressor (VFD) Supply air temperature sensor Main circuit breaker Item Description Fan (2) Fan guard (2) Electrical panel Communication and external device connectors Ground lug Humidity sensor 23 ACRD100, ACRD200, ACRD600, and ACRD600P Series Technical Data na5824a Rear (ACRD60x) Item 24 Description Evaporator coil Sight glass Condensate drain pan Filter drier Oil separator Item Description Condensate pump Air filters Pipe chase Return air temperature sensor 990-5801C-001 Technical Data ACRD100, ACRD200, ACRD600, and ACRD600P Series na5821a Front (ACRD60xP) Item Description Electric heater Condensate drain pan Electronic expansion valve Humidifier Compressor Variable frequency drive for compressor (VFD) Supply air temperature sensor 990-5801C-001 Item Description Main circuit breaker Fan (2) Fan guard (2) Electrical panel Communication and external device connectors Ground lug Humidity sensor 25 ACRD100, ACRD200, ACRD600, and ACRD600P Series Technical Data na5822a Rear (ACRD60xP) Item 26 Description Evaporator coil Sight glass Condensate drain pan Filter drier Oil separator Condensate pump Item Description Humidifier Air filters Pipe chase Humidity sensor Return air temperature sensor 990-5801C-001 Technical Data ACRD100, ACRD200, ACRD600, and ACRD600P Series Electrical Panels na2664a ACRD100 and ACRD200 Series Item 990-5801C-001 Description Leak detector port Remote temperature sensor port A-Link ports Reset button Network port Building management system (BMS) RS-485 port Control RS-485 port Form C and shutdown input RS-232 console port Outdoor heat exchanger (OHE) ports (optional) 27 ACRD100, ACRD200, ACRD600, and ACRD600P Series Technical Data ACRD600, ACRD601, ACRD602 Item Description Transformers Display interface connectors Main controller board Relay board Ground lug Main circuit breaker Compressor fuse block (ACRD600, ACRD601) Compressor circuit breaker (ACRD602) Fan circuit breakers Fuse not populated Transformer A fuse Transformer C/MB fuse NOTE: For a top installation, control wiring is routed through the wire channel located at the top-left corner, just above the user interface connectors. na2724b For a bottom installation, the control wiring is routed to the access hole in the bottom of the equipment through wire clamps from the interface connectors. Then, the wiring is routed down along the electrical panel and secured with wire clamps 28 990-5801C-001 Technical Data ACRD100, ACRD200, ACRD600, and ACRD600P Series ACRD600P, ACRD601P, ACRD602P Item Description Transformers Display interface connectors Main controller board Relay board Ground lug Main circuit breaker Compressor fuse block (ACRD600P, ACRD601P) Compressor circuit breaker (ACRD602P) Fan circuit breakers Controller fuse Heater circuit breaker Humidifier circuit fuse Heater contactors Humidifier contactor NOTE: For a top installation, control wiring is routed through the wire channel located at the top-left corner, just above the user interface connectors. na2032b For a bottom installation, the control wiring is routed to the access hole in the bottom of the equipment through wire clamps from the interface connectors. Then, the wiring is routed down along the electrical panel and secured with wire clamps 990-5801C-001 29 ACRD100, ACRD200, ACRD600, and ACRD600P Series Technical Data Customer Interface Connections—ACRD100 and ACRD200 Series LEAK DETECT COM RUN OUTPUT NO OHE ALARM INPUT 24V AC/DC + - COM RUN OUTPUT NO ALARM INPUT 24V AC/DC + - RACK TEMPERATURE USER INTERFACE CONNECTIONS WIRE AS CLASS 2 CIRCUITS ONLY RS-232 CONSOLE PORT 9600-8-N-1 DTE SHUTDOWN INPUT CONTACTS AND ALARM OUTPUT CONTACTS NC OUTPUT RELAY COM NO GND VOLTAGE OUTPUT +12 V +24 V SHUTDOWN INPUT 12-30V AC/DC + D1 CONTROL RS-485 D0 GND CONTROL MODBUS D1 MODBUS RS-485 D0 GND LINK RX/TX 10/100 BASE-T NETWORK PORT STATUS 10 = GREEN 100 = ORANGE RESET 885-3432_REVE1 Item Description A-Link ports: Pin 1 = High; pin 2 = Low; Pins 3,6 = Perf Power; Pins 4, 5 = Ground Reset button Network port Shield/ground RTRX(-) Item na2688a 24VDC Description NO (normally open contact) COM (common contact) NC (normally closed contact) RS-232 console port OHE (outdoor heat exchanger) alarm input - (not used) OHE alarm input + (not used) OHE COM (optional*) OHE NO port (optional*) Leak detector port (AP9325) Remote temperature sensor RTRX(+) Shutdown – Shutdown + 24 VDC (bias) 12 VDC (bias) Return (bias) *To avoid unnecessary condenser operation when the ambient temperature exceeds 43°C (110°F), connect these leads. 30 990-5801C-001 Technical Data ACRD100, ACRD200, ACRD600, and ACRD600P Series Customer Interface Connections—ACRD600 and ACRD600P Series NOTE: Wire all input and output connections as Class 2 circuits. Depending on the configuration, additional customer interface connections may be required for the A-Link remote communications through the Network Management Card support or traditional equipment-monitoring software. Description Rack inlet temperature sensors 1, 2, 3 A-Link IN A-Link OUT Network port Customer output, NC (normally closed) Customer output, COM (common) Customer output, NO (normally open) Supply GND (Ground) Supply 12 VDC (current limit: 20 mA) Supply 24 VDC (current limit: 20 mA) Customer input + (12–30 VAC/VDC, 24 VDC @ 11 mA) Supply COM RTRX(-) RTRX(+) Modbus GND Supply air temperature sensor (front) Supply air humidity sensor (front) na2009b Item 990-5801C-001 31 ACRD100, ACRD200, ACRD600, and ACRD600P Series Item Description Rack inlet temperature sensors 1, 2, 3 A-Link IN A-Link OUT Network port Technical Data Three temperature sensors which must be installed on the cold aisle side of the server racks. See In and out connections for A-Link. The terminators supplied with the equipment must be plugged into the first A-link port and the final A-Link port for the group. 10/100 Base-T Network port. Connects the equipment to the network; Status and Link LEDs indicate network traffic. • Status LED—blinks orange and green at startup; indicates the status of the network connection (solid green—IP address established; blinking green— attempting to obtain an IP address). • Customer output, NC (normally closed) Customer output, COM (common) Customer output, NO (normally open) Supply GND (Ground) Supply 12 VDC (current limit: 20 mA) Supply 24 VDC (current limit: 20 mA) Customer input + (12–30 VAC/VDC, 24 VDC @ 11 mA) Supply COM RTRX(-) RTRX(+) Modbus GND Supply air temperature sensor (front) Supply air humidity sensor (front) 32 Link LED—blinks to indicate network traffic (green — operating at at 10 mbps; orange—operating at 100 Customer-configurable output relay which can be activated for all types of alarms or critical alarms. The relay can be connected to external equipment using 30 VAC/VDC, 2 A. Can be used for customer input and output interface. Can be used for customer input and output interface. Current limit is 20 mA. Can be used for customer input and output interface. Current limit is 20 mA. Used for remote shutdown of an InRow DX unit. Voltage is applied from the internal power supply or by using an external power supply. Ground connection point for remote shutdown supply source. Connections for Building Management System. Wire a 150-Ohm terminator resistor (supplied) into the final InRow DX unit, between Modbus D0 and Modbus D1. Temperature sensor installed on the front of the equipment. Humidity sensor installed on the front of the equipment. 990-5801C-001 Technical Data ACRD100, ACRD200, ACRD600, and ACRD600P Series Performance Specifications Net Cooling Capacity Air-Cooled and Glycol-Cooled Units Cooling Performance at a Fixed Compressor Speed Return Air Temperature 22.2°C DB, 15.5°C WB (72.0°F DB, 60.0°F WB) 23.9°C DB, 16.2°C WB (75.0°F DB, 61.1°F WB) 26.7°C DB, 19.4°C WB (80.0°F DB, 67.0°F WB) 26.7°C DB, 17.1°C WB (80.0°F DB, 62.8°F WB) 29.4°C DB, 18.1°C WB (85.0°F DB, 64.6°F WB) Model Total Capacity – kW (BTU/ hr) Sensible Capacity – kW (BTU/hr) ACRD100 8.22 (28,000) 8.04 (27,000) ACRD101 8.01 (27,000) 7.71 (26,000) ACRD200 8.22 (28,000) 8.04 (27,000) ACRD201 8.01 (27,000) 7.71 (26,000) ACRD600, ACRD600P 26.87 (92,000) 21.03 (72,000) ACRD100 8.52 (29,000) 8.52 (29,000) ACRD101 8.16 (28,000) 8.16 (28,000) ACRD200 8.52 (29,000) 8.52 (29,000) ACRD201 8.16 (28,000) 8.16 (28,000) ACRD600, ACRD600P 27.78 (95,000) 22.99 (79,000) ACRD100 10.02 (34,000) 9.12 (31,000) ACRD101 9.72 (33,000) 8.85 (30,000) ACRD200 10.02 (34,000) 9.12 (31,000) ACRD201 9.72 (33,000) 8.85 (30,000) ACRD600, ACRD600P N/A N/A ACRD100 9.36 (32,000) 9.36 (32,000) ACRD101 8.97 (31,000) 8.97 (31,000) ACRD200 10.02 (34,000) 9.12 (31,000) ACRD201 9.72 (33,000) 8.85 (30,000) ACRD600, ACRD600P 28.94 (99,000) 26.55 (92,000) ACRD100 9.90 (34,000) 9.90 (34,000) ACRD101 9.69 (33,000) 9.69 (33,000) ACRD200 9.90 (34,000) 9.90 (34,000) ACRD201 9.69 (33,000) 9.69 (33,000) ACRD600, ACRD600P 30.19 (103,000) 29.72 (99,000) 1Airflow is reduced to 887 l/s (1880 SCFM) at this condition to maintain adequate evaporating temperature. is reduced to 717 l/s (1520 SCFM) at this condition to maintain adequate evaporating temperature. 3Airflow is reduced to 599 l/s (1270 SCFM) at this condition to maintain adequate evaporating temperature. 4Airflow is reduced to 510 l/s (1080 SCFM) at this condition to maintain adequate evaporating temperature. 5Airflow is reduced to 448 l/s (950 SCFM) at this condition to maintain adequate evaporating temperature. *Airflow reduced to 3300 SCFM at this condition to maintain adequate return gas temperature. ** Airflow is reduced to 1353 l/s (2900 SCFM) at this condition to maintain adequate evaporating temperature. Airflow at full evaporating fan speed: ACRD100/200 series—1081 l/s (2290 SCFM); ACRD600 and ACRD600P series—1900 l/s (4000 SCFM) Minimum recommended loads: ACRD100/200 series—2 kW (6831 BTU); ACRD600 and ACRD600P series—8 kW (34,152 BTU) 2Airflow NOTE: For ACRD100, ACRD600, and ACRD600P series, the outdoor air temperature is 35°C (95°F). NOTE: For ACRD200 series, a 40% at 0.64 l/s (10 gpm) entering glycol mixture temperature is 40.6°C (105°F). 990-5801C-001 33 ACRD100, ACRD200, ACRD600, and ACRD600P Series Technical Data Cooling Performance at a Fixed Compressor Speed Return Air Temperature 32.2°C DB, 19.0°C WB (90.0°F DB, 66.2°F WB) 35.0°C DB, 19.9°C WB (95.0°F DB, 67.8°F WB) 37.8°C DB, 20.7°C WB (100.0°F DB, 69.3°F WB) 40.6°C DB, 21.6°C WB) (105.0°F DB, 70.8°F WB 43.3°C DB, 22.2°C WB) (110.0°F DB, 72.0°F WB Model Total Capacity – kW (BTU/ hr) Sensible Capacity – kW (BTU/hr) ACRD1001 10.44 (36,000) 10.44 (36,000) ACRD1011 10.29 (35,000) 10.29 (35,000) ACRD2001 10.44 (36,000) 10.44 (36,000) ACRD2011 10.29 (35,000) 10.29 (35,000) ACRD600, ACRD600P 31.96 (109,000) 31.96 (109,000) ACRD1002 10.62 (36,000) 10.62 (36,000) ACRD1012 10.50 (36,000) 10.50 (36,000) ACRD2002 10.62 (36,000) 10.62 (36,000) ACRD2012 10.50 (36,000) 10.50 (36,000) ACRD600, ACRD600P 33.97 (116,000) 33.97 (116,000) ACRD1003 10.62 (36,000) 10.62 (36,000) ACRD1013 10.50 (36,000) 10.50 (36,000) ACRD2003 10.62 (36,000) 10.62 (36,000) ACRD2013 10.50 (36,000) 10.50 (36,000) ACRD600, ACRD600P 35.91 (123,000) 35.91 (123,000) ACRD1004 10.56 (36,000) 10.56 (36,000) ACRD1014 10.5 (36,000) 10.5 (36,000) ACRD2004 10.56 (36,000) 10.56 (36,000) ACRD2014 10.5 (36,000) 10.5 (36,000) ACRD600, ACRD600P* 35.55 (121,000) 35.55 (121,000) ACRD1005 10.6 (36,000) 10.6 (36,000) ACRD1015 10.5 (36,000) 10.5 (36,000) ACRD2005 10.6 (36,000) 10.6 (36,000) ACRD2015 10.5 (36,000) 10.5 (36,000) ACRD600, ACRD600P** 35.57 (121,000) 35.57 (121,000) 1Airflow is reduced to 887 l/s (1880 SCFM) at this condition to maintain adequate evaporating temperature. is reduced to 717 l/s (1520 SCFM) at this condition to maintain adequate evaporating temperature. 3Airflow is reduced to 599 l/s (1270 SCFM) at this condition to maintain adequate evaporating temperature. 4Airflow is reduced to 510 l/s (1080 SCFM) at this condition to maintain adequate evaporating temperature. 5Airflow is reduced to 448 l/s (950 SCFM) at this condition to maintain adequate evaporating temperature. *Airflow reduced to 3300 SCFM at this condition to maintain adequate return gas temperature. ** Airflow is reduced to 1353 l/s (2900 SCFM) at this condition to maintain adequate evaporating temperature. Airflow at full evaporating fan speed: ACRD100/200 series—1081 l/s (2290 SCFM); ACRD600 and ACRD600P series—1900 l/s (4000 SCFM) Minimum recommended loads: ACRD100/200 series—2 kW (6831 BTU); ACRD600 and ACRD600P series—8 kW (34,152 BTU) 2Airflow NOTE: For ACRD100, ACRD600, and ACRD600P series, the outdoor air temperature is 35°C (95°F). NOTE: For ACRD200 series, a 40% at 0.64 l/s (10 gpm) entering glycol mixture temperature is 40.6°C (105°F). 34 990-5801C-001 Technical Data ACRD100, ACRD200, ACRD600, and ACRD600P Series Water-Cooled Units Cooling Performance at a Fixed Compressor Speed Return Air Temperature 22.2°C DB, 15.5°C WB (72.0°F DB, 60.0°F WB) 23.9°C DB, 16.2°C WB (75.0°F DB, 61.1°F WB) 26.7°C DB, 19.4°C WB (80.0°F DB, 67.0°F WB) 26.7°C DB, 17.1°C WB (80.0°F DB, 62.8°F WB) 29.4°C DB, 18.1°C WB (85.0°F DB, 64.6°F WB) Model Total Capacity – kW (BTU/ hr) Sensible Capacity – kW (BTU/hr) ACRD200 9.72 (33,000) 8.94 (31000) ACRD201 9.57 (33,000) 8.79 (30,000) ACRD200 8.43 (32,000) 8.43 (32,000) ACRD201 9.30 (32,000) 9.30 (32,000) ACRD200 11.52 (39,000) 9.90 (34,000) ACRD201 11.64 (40,000) 9.99 (34,000) ACRD200 10.38 (35,000) 10.38 (35,000) ACRD201 10.11 (35,000) 10.11 (35,000) ACRD200 10.92 (37,000) 10.92 (37,000) ACRD201 10.98 (38,000) 10.98 (38,000) Airflow is reduced to 887 l/s (1880 SCFM) at the condition below to maintain adequate evaporating temperature. 32.2°C DB, 19.0°C WB (90.0°F DB, 66.2°F WB) ACRD200 11.64 (40,000) 11.64 (40,000) ACRD201 11.76 (40,000) 11.76 (40,000) Airflow is reduced to 717 l/s (1520 SCFM) at the condition below to maintain adequate evaporating temperature. 35.0°C DB, 19.9°C WB (95.0°F DB, 67.8°F WB) ACRD200 12.00 (41,000) 12.00 (41,000) ACRD201 12.00 (41,000) 12.00 (41,000) Airflow is reduced to 599 l/s (1270 SCFM) at the condition below to maintain adequate evaporating temperature. 37.8°C DB, 20.7°C WB (100.0°F DB, 69.3°F WB) ACRD200 12.06 (41,000) 12.06 (41,000) ACRD201 12.00 (41,000) 12.00 (41,000) Airflow is reduced to 510 l/s (1080 SCFM) at the condition below to maintain adequate evaporating temperature. 40.6°C DB, 21.6°C WB) (105.0°F DB, 70.8°F WB ACRD200 12.06 (41,000) 12.00 (41,000) ACRD201 12.00 (41,000) 12.00 (41,000) Airflow is reduced to 448 l/s (950 SCFM) at the condition below to maintain adequate evaporating temperature. 43.3°C DB, 22.2°C WB) (110.0°F DB, 72.0°F WB ACRD200 12.06 (41,000) 12.06 (41,000) ACRD201 12.06 (41,000) 12.06 (41,000) Airflow for the ACRD200 series is 1081 l/s (2290 SCFM) at full evaporating fan speed. NOTE: Minimum recommended loads: ACRD200 series—2 kW (6831 BTU) NOTE: For ACRD200 series, a 0.64 l/s (10 gpm) entering water temperature is 29.4°C (85°F). 990-5801C-001 35 ACRD100, ACRD200, ACRD600, and ACRD600P Series Technical Data Performance at Percentage of Fan Speed ACRD100 Series Cooling Performance at a Target Supply Air Temperature of 20.8°C (69.5°F) when Possible Fan Speed – % Voltage/Ph/Hz Air Flow – L/S (SCFM) Unit Power – kW Condenser Fan Power – kW Net Sensible Capacity – kW (BTU/h) Supply Air Temp – ° C (°F) 2.57 0.13 4.60 (15,710) 20.8 (69.5) 2.58 0.13 4.60 (15,710) 20.8 (69.5) 2.67 0.18 5.75 (19,637) 20.8 (69.5) 2.70 0.20 5.75 (19,637) 20.8 (69.5) 2.76 0.23 6.65 (22,711) 20.8 (69.5) 2.80 0.25 6.65 (22,711) 20.8 (69.5) 2.86 0.28 7.35 (25,102) 20.8 (69.5) 2.90 0.29 7.35 (25,102) 20.8 (69.5) 2.92 0.32 8.00 (27,321) 20.8 (69.5) 2.98 0.35 8.00 (27,321) 20.8 (69.5) 3.04 0.38 8.70 (29,712) 20.8 (69.5) 3.08 0.40 8.70 (29,712) 20.8 (69.5) 3.19 0.47 9.70 (33,127) 20.8 (69.5) 3.22 0.49 9.70 (33,127) 20.8 (69.5) 3.46 0.50 9.90 (33,810) 21.7 (71.1) 3.50 0.51 9.90 (33,810) 21.9 (71.5) 2.68 0.28 7.55 (25,785) 20.8 (69.5) 2.70 0.30 7.55 (25,785) 20.8 (69.5) 2.80 0.42 9.50 (32,444) 20.8 (69.5) 2.81 0.44 9.50 (32,444) 20.8 (69.5) 2.89 0.48 10.20 (34,835) 21.8 (71.2) 2.91 0.48 9.90 (33,810) 22.2 (71.9) 3.00 0.52 10.62 (36,269) 22.6 (72.6) 3.01 0.50 10.29 (35,142) 23.1 (73.5) N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Return Air Temperature—29.4°C (85°F) 200-240/1/60 448 (950) 30 200-240/1/50 200-240/1/60 562 (1190) 40 200-240/1/50 200-240/1/60 947 (1370) 50 200-240/1/50 200-240/1/60 717 (1520) 60 200-240/1/50 200-240/1/60 779 (1650) 70 200-240/1/50 200-240/1/60 850 (1800) 80 200-240/1/50 200-240/1/60 944 (2000) 90 200-240/1/50 200-240/1/60 1081 (2290) 100 200-240/1/50 Return Air Temperature—35°C (95°F) 200-240/1/60 448 (950) 30 200-240/1/50 200-240/1/60 562 (1190) 40 200-240/1/50 200-240/1/60 947 (1370) 50 200-240/1/50 200-240/1/60 717 (1520) 60 200-240/1/50 200-240/1/60 70 N/A 200-240/1/50 200-240/1/60 80 N/A 200-240/1/50 200-240/1/60 90 N/A 200-240/1/50 200-240/1/60 100 N/A 200-240/1/50 36 990-5801C-001 Technical Data ACRD100, ACRD200, ACRD600, and ACRD600P Series Cooling Performance at a Target Supply Air Temperature of 20.8°C (69.5°F) when Possible Fan Speed – % Voltage/Ph/Hz Air Flow – L/S (SCFM) Unit Power – kW Condenser Fan Power – kW Net Sensible Capacity – kW (BTU/h) Supply Air Temp – ° C (°F) 2.78 0.47 10.20 (34,835) 21.3 (70.4) 2.78 0.48 10.00 (34,152) 21.6 (70.9) 2.85 0.51 10.56 (36,064) 24.8 (76.6) 2.87 0.53 10.55 (36,030) 24.8 (76.6) N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Return Air Temperature—40.6°C (105°F) 200-240/1/60 448 (950) 30 200-240/1/50 200-240/1/60 562 (1190) 40 200-240/1/50 200-240/1/60 50 N/A 200-240/1/50 200-240/1/60 60 N/A 200-240/1/50 200-240/1/60 70 N/A 200-240/1/50 200-240/1/60 80 N/A 200-240/1/50 200-240/1/60 90 N/A 200-240/1/50 200-240/1/60 100 N/A 200-240/1/50 990-5801C-001 37 ACRD100, ACRD200, ACRD600, and ACRD600P Series Technical Data ACRD200 Series Cooling Performance at a Target Supply Air Temperature of 20.8°C (69.5°F) when Possible Fan Speed – % Voltage/Ph/Hz Air Flow – L/S (SCFM) Unit Power – kW Net Sensible Capacity – kW (BTU/h) Supply Air Temp – °C (°F) 2.35 4.60 (15,710) 20.8 (69.5) 2.25 4.60 (15,710) 20.8 (69.5) 2.41 5.76 (19,671) 20.8 (69.5) 2.31 5.76 (19,671) 20.8 (69.5) 2.47 6.63 (22,643) 20.8 (69.5) 2.37 6.63 (22,643) 20.8 (69.5) 2.55 7.36 (25,136) 20.8 (69.5) 2.45 7.36 (25,136) 20.8 (69.5) 2.60 8.00 (27,321) 20.8 (69.5) 2.50 8.00 (27,321) 20.8 (69.5) 2.68 8.70 (29,712) 20.8 (69.5) 2.58 8.70 (29,712) 20.8 (69.5) 2.80 9.70 (33,127) 20.8 (69.5) 2.70 9.70 (33,127) 20.8 (69.5) 3.06 10.90 (37,225) 21.0 (69.8) 3.00 10.98 (37,499) 20.9 (69.7) 2.25 7.50 (25,614) 20.8 (69.5) 2.25 7.50 (25,614) 20.8 (69.5) 2.31 9.50 (32.444) 20.8 (69.5) 2.31 9.50 (32.444) 20.8 (69.5) 2.37 10.50 (35,859) 21.2 (70.2) 2.37 10.50 (35,859) 21.2 (70.2) 2.50 11.35 (38,762) 21.8 (71.3) 2.45 11.35 (38,762) 21.8 (71.3) 2.61 11.75 (40,128) 22.4 (72.4) 2.50 11.75 (40,128) 22.4 (72.4) 2.71 12.00 (40,982) 23.2 (73.7) 2.58 12.00 (40,982) 23.2 (73.7) N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Return Air Temperature—29.4°C (85°F) 200-240/1/60 448 (950) 30 200-240/1/50 200-240/1/60 562 (1190) 40 200-240/1/50 200-240/1/60 947 (1370) 50 200-240/1/50 200-240/1/60 717 (1520) 60 200-240/1/50 200-240/1/60 779 (1650) 70 200-240/1/50 200-240/1/60 850 (1800) 80 200-240/1/50 200-240/1/60 944 (2000) 90 200-240/1/50 200-240/1/60 1081 (2290) 100 200-240/1/50 Return Air Temperature—35°C (95°F) 200-240/1/60 448 (950) 30 200-240/1/50 200-240/1/60 562 (1190) 40 200-240/1/50 200-240/1/60 947 (1370) 50 200-240/1/50 200-240/1/60 717 (1520) 60 200-240/1/50 200-240/1/60 779 (1650) 70 200-240/1/50 200-240/1/60 850 (1800) 80 200-240/1/50 200-240/1/60 90 N/A 200-240/1/50 200-240/1/60 100 N/A 200-240/1/50 38 990-5801C-001 Technical Data ACRD100, ACRD200, ACRD600, and ACRD600P Series Cooling Performance at a Target Supply Air Temperature of 20.8°C (69.5°F) when Possible Fan Speed – % Voltage/Ph/Hz Air Flow – L/S (SCFM) Unit Power – kW Net Sensible Capacity – kW (BTU/h) Supply Air Temp – °C (°F) 448 (950) 2.35 10.55 36,030) 20.8 (69.5) 2.25 10.55 36,030) 20.8 (69.5) 2.40 11.70 (39,958) 22.8 (73.0) 2.31 11.70 (39,958) 22.8 (73.0) 2.46 12.00 (40,982) 24.8 (76.7) 2.37 12.00 (40,982) 24.8 (76.7) N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Return Air Temperature—40.6°C (105°F) 30 200-240/1/60 200-240/1/50 40 200-240/1/60 562 (1190) 200-240/1/50 50 200-240/1/60 947 (1370) 200-240/1/50 60 200-240/1/60 N/A 200-240/1/50 70 200-240/1/60 N/A 200-240/1/50 80 200-240/1/60 N/A 200-240/1/50 90 200-240/1/60 N/A 200-240/1/50 100 200-240/1/60 200-240/1/50 990-5801C-001 N/A 39 ACRD100, ACRD200, ACRD600, and ACRD600P Series Technical Data ACRD600 Series (No Humidification/No Reheat) Cooling Performance at a Target Supply Air Temperature of 20.8°C (69.5°F) when Possible Fan Speed – % Air Flow – L/S (SCFM) Unit Power – kW Condenser Fan Power – kW Net Sensible Capacity – kW (BTU/h) Supply Air Temp – °C (°F) Return Air Temperature—29.4°C (85°F) 30 600 (1200) 2.89 0.96 11.3 (38,583) 12.9 (55.2)* 40 800 (1600) 2.93 0.98 13.1 (44,729) 15.0 (59.0)* 50 900 (2000) 2.98 1.00 13.9 (47,461) 17.2 (63.0)* 60 1100 (2400) 3.12 1.02 14.5 (49,509) 18.8 (65.8)* 70 1300 (2800) 3.86 1.05 17.1 (58,387) 18.7 (65.7) 80 1500 (3200) 4.11 1.05 17.4 (59,411) 19.9 (67.8) 90 1700 (3600) 5.01 1.05 19.72 (67,332) 19.8 (67.6) 100 1900 (4000) 5.78 1.05 19.9 (67,947) 20.8 (69.4) Return Air Temperature—35°C (95°F) 30 600 (1200) 2.88 0.99 13.4 (45,753) 15.4 (59.7)* 40 800 (1600) 2.91 1.02 14.87 (50,773) 18.7 (65.7)* 50 900 (2000) 3.54 1.05 17.9 (61,118) 19.3 (66.7) 60 1100 (2400) 4.29 1.05 20.9 (71,361) 19.8 (67.6) 70 1300 (2800) 5.14 1.05 23.6 (80,580) 20.3 (68.5) 80 1500 (3200) 6.07 1.05 26.0 (88,775) 20.8 (69.4) 90 1700 (3600) 7.09 1.05 29.2 (99,701) 20.8 (69.4) 100 1900 (4000) 9.50 1.05 32.9 (112,260) 20.8 (69.4) Return Air Temperature—40.6°C (105°F) 30 600 (1200) 2.86 1.02 14.9 (50,875) 18.8 (65.8)* 40 800 (1600) 4.08 1.05 20.4 (69,654) 18.3 (64.9) 50 900 (2000) 4.80 1.05 23.9 (81,605) 19.7 (67.5) 60 1100 (2400) 6.36 1.05 28.7 (97,994) 19.6 (67.3) 70 1300 (2800) 7.33 1.05 31.7 (108,165) 20.8 (69.4) 80 1500 (3200) 9.19 1.05 36.1 (123,178) 20.8 (69.4) 90 1700 (3600) 11.57 1.05 40.7 (138,874) 20.8 (69.4) 100 1900 (4000) 12.47 1.05 41.9 (142,969) 22.5 (72.5) *In this case, the compressor will cycle because its speed is down to the minimum of 25 Hz. The minimum fan speed for the InRow mode is 30%; the minimum fan speed for HACS and RACS mode is 40%. NOTE: Outdoor temperature is 35°C (95°F). 40 990-5801C-001 Technical Data ACRD100, ACRD200, ACRD600, and ACRD600P Series General Data General Specifications—ACRD200 Series Water Cooled Glycol Mixture Cooled Nominal flow rate entering the unit – l/s (GPM) 0.64 (10.0) 0.64 (10.0) Design entering temperature – °C (°F) 29.4 (85.0) 40.6 (105.0) Maximum heat rejection – kW (BTU/hr) 15.2 (52,000) 15.2 (52,000) 0 40 12.8–43.3 (55.0–110.0) 12.8–43.3 (55.0–110.0) 33.1 (4.8) 43.4 (6.3) Data Maximum glycol percentage – % Temperature range of fluid entering the unit at a flow rate of 0.64 l/s (10 GPM) – °C (°F) Unit pressure drop at 0.64 l/s (10 GPM) – kPa (psi) 990-5801C-001 41 ACRD100, ACRD200, ACRD600, and ACRD600P Series Technical Data Fluid-Cooled Unit Specifications Model ACRD200 Series Air System—Fan (Standard Filter Installed) Size – mm (in.) Air Volume – l/s (SCFM) Fan Motor – W (HP) each Number of Fans 200 (7.9) 1080 (2290) 115 (0.15) 6 Cooling Coil—Copper Tube/Aluminum Fin Face Area – m2 (ft2) Rows Deep 0.37 (3.97) 2 Filters—Washable (Standard) Quantity Size – mm (in.) Depth – mm (in.) Efficiency (%) 2 238 X 933 (9.375 X 36.75) 13 (1/2) <20% MERV 1 Filters—Pleated (Optional) Quantity Size – mm (in.) Depth – mm (in.) Efficiency (%) 2 238 X 933 (9.375 X 36.75) 51 (2) 30% MERV 8 Physical Data Weight – kg (lb) 199.09 (438) Height – mm (in.) 1991 (78.39) Width – mm (in.) 300 (11.8) Depth – mm (in.) 1070 (42.13) Connection Sizes Liquid In 7/8-in. ODF brazed Return 7/8-in. ODF brazed Condensate Drain Drain Line 3/16-in. ID, 5/16-in. OD Refrigerant 42 Type R410A Charge – kg (oz) 2.2 (78) 990-5801C-001 Technical Data ACRD100, ACRD200, ACRD600, and ACRD600P Series Air-Cooled Unit Specifications Data Model Value ACRD100 series 200 (7.9) ACRD600, ACRD600P series 400 (15.8) ACRD100 series 1080 (2290) ACRD600, ACRD600P series 1900 (4000) ACRD100 series 115 (0.15) ACRD600, ACRD600P series 1100 (1.5) ACRD100 series 6 ACRD600, ACRD600P series 2 ACRD100 series 0.37 (3.97) ACRD600, ACRD600P series 0.56 (6.0) ACRD100 series 2 ACRD600, ACRD600P series 4 Air System—Fan (Standard Filter Installed) Size – mm (in.) Air Volume – l/s (SCFM) Fan Motor – W (HP) each Number of Fans Cooling Coil—Copper Tube/Aluminum Fin Face Area – m2 (ft2) Rows Deep Filters—Washable (Standard) Quantity 2 Size – mm (in.) 238 X 933 (9.375 X 36.75) ACRD100 series Depth – mm (in.) 13 (1/2) Efficiency (%) <20% MERV 1 Filters—Pleated (Standard) Quantity 3 Size – mm (in.) 418 x 470 (16.45 x 18.5) ACRD600, ACRD600P series Depth – mm (in.) 101.6 (4) Efficiency (%) 30 Filters—Pleated (Optional) Quantity 2 Size – mm (in.) 238 X 933 (9.375 X 36.75) ACRD100 series Depth – mm (in.) 51 (2) Efficiency (%) 30% MERV 8 Filters—Pleated (Optional) Quantity 3 Size – mm (in) 418 x 470 (16.45 x 18.5) ACRD600, ACRD600P series Depth – mm (in.) Efficiency (%) 990-5801C-001 101.6 (4) 85 43 ACRD100, ACRD200, ACRD600, and ACRD600P Series Data Technical Data Model Value ACRD100 series 183 (404) ACRD600 402 (886) ACRD601/ACRD602 391 (862) ACRD600P 413 (911) ACRD601P/ACRD602P 402 (886) ACRD100 series 1991 (78.39) ACRD600, ACRD600P series 1991 (78.39) ACRD100 series 300 (11.8) ACRD600, ACRD600P series 600 (23.62) ACRD100 series 1070 (42.13) ACRD600, ACRD600P series 1070 (42.13) ACRD100 series 1/2-in. ODF brazed ACRD600, ACRD600P series 3/4-in. ODF brazed ACRD100 series 1/2-in. ODF brazed ACRD600, ACRD600P series 3/4-in. ODF brazed ACRD100 series 3/16-in. ID, 5/16-in. OD ACRD600, ACRD600P series 1/2 ACRD600, ACRD600P series 6.35 (1/4) ACRD100 series R410A (amount determined at installation) ACRD600, ACRD600P series R410A (amount determined at installation) Flush Cycle ACRD600P series Automatic Capacity – kg/hr (lb/hr) ACRD600P series 3.0 (6.6) kW ACRD600P series 2.25 Physical Data Weight – kg (lb) Height – mm (in.) Width – mm (in.) Depth – mm (in.) Connection Sizes Refrigerant Discharge Liquid Condensate Drain Drain Line – in. Humidifier Supply Line – mm (in.) Refrigerant Type Humidification—Solid State Electrode Canister Reheat—Electric (Equally Loaded Three Stage, Finned Tubular, Low-watt Density) 44 Capacity – kW (BTU/hr) ACRD600P series 6.0 (20,491) Stages ACRD600P series 2 990-5801C-001 Technical Data ACRD100, ACRD200, ACRD600, and ACRD600P Series Altitude Correction Factors Room Conditions: 22°C (72°F) DB/50%RH Altitude – m (ft) Specific Volume – cm3/ kg (ft3/lb) Density –g/m3 (lb/ft3) Density Ratio* Capacity Correction** 0 (0) 847.77 (13.58) 1185.37 (0.074) 1.000 1.000 305 (1000) 879.61 (14.09) 1137.31 (0.071) 0.964 0.981 610 (2000) 912.70 (14.62) 1089.26 (0.068) 0.929 0.962 915 (3000) 947.66 (15.18) 1057.22 (0.066) 0.895 0.933 1219 (4000) 983.86 (15.76) 1009.16 (0.063) 0.862 0.913 1524 (5000) 1021.32 (16.36) 977.13 (0.061) 0.830 0.884 1829 (6000) 1061.28 (17.00) 945.10 (0.059) 0.799 0.865 2134 (7000) 1103.10 (17.67) 913.05 (0.057) 0.769 0.846 2438 (8000) 1146.80 (18.37) 865.00 (0.054) 0.739 0.826 2743 (9000) 1193.00 (19.11) 832.97 (0.052) 0.711 0.807 3048 (10,000) 1241.69 (19.89) 80.92 (0.050) 0.683 0.787 *Density ratio is used for air flow correction factor. **Capacity correction is used to de-rate performance. 990-5801C-001 45 ACRD100, ACRD200, ACRD600, and ACRD600P Series Technical Data Electrical Data Compressor Model MCA** MOP** FLA** LRA RLA Power ACRD100—208-240 V, 1 Ph, 60 Hz 25.0 40 N/A 87.5 16.0 4.6 ACRD101—220-240 V, 1 Ph, 50 Hz N/A N/A 21 97.0 16.3 4.4 ACRD200—208-240 V, 1 Ph, 60 Hz 25.0 40 N/A 87.5 16.0 4.6 ACRD201—220-240 V, 1 Ph, 50 Hz N/A N/A 21 97.0 16.3 4.4 ACRD600—200-240 V, 3 Ph, 50/60 Hz 52.6 80 N/A 29.7* 36.6 14.6 ACRD601—460-480 V, 3 Ph, 60 Hz 24.4 40 N/A 28.1* 16.6 14.6 ACRD602—380-415 V, 3 Ph, 50/60 Hz 31.1 50 25.2 28.1* 16.6 14.6 ACRD600P—200-240 V, 3 Ph, 50/60 Hz 78.6 110 N/A 29.7* 36.6 23.5 ACRD601P—460-480 V, 3 Ph, 60 Hz 36.9 50 N/A 28.1* 16.6 23.5 ACRD602P—380-415 V, 3 Ph, 50/60 Hz 45.8 60 34.2 28.1* 16.6 23.5 NOTE: Above data is based on maximum operating condition. Evaluated at maximum allowable operating conditions of: 39°C (102°F) DB, 11.1°C (52.0°F) DP, 46.0°C (115.0°F) ambient, 100% fan speed, 78 Hz compressor. NOTE: Installation must comply with national and/or local electrical codes. NOTE: All models are hard-wired. NOTE: Use LRA for estimation of inrush current. * The compressor is powered by the VFD. **Cells marked N/A indicate that this information is not required because of regional differences in electrical codes. 46 990-5801C-001 Technical Data ACRD100, ACRD200, ACRD600, and ACRD600P Series Sound Data ACRD100 and ACRD200 Series Tested Sound Data Fan Speed – % Fan – RPM Lp Sound Pressure –dB re: 20 µPa* Sound Power dB at Frequency – Hz re: 10-12W Airflow – m3/ s (SCFM) 125 250 500 1000 2000 4000 8000 dBA** dBA 60 2300 0.66 (1400) 62.3 68.3 69.8 74.8 67.8 59.3 53.3 76.5 70.5 70 3000 0.78 (1650) 65.3 76.3 74.8 77.8 73.8 67.8 61.3 80.8 74.7 80 3450 0.85 (1800) 67.3 80.3 77.3 78.2 76.3 71.8 66.3 82.7 76.6 90 3800 0.92 (1950) 68.3 81.8 78.8 80.8 77.3 74.3 68.3 84.5 78.4 100 4300 1.08 (2290) 70.3 80.8 83.3 85.3 80.3 77.8 72.3 88.3 82.2 m3 (1000 *Weighted sound pressure dBA in a 28.3 **Based on compressor operating at full speed. ft3) room at 1.5 m (5-ft) distance. ACRD600 and ACRD600P Series Air-Cooled Tested Sound Data Fan Speed – % Lp Sound Pressure –dB re: 20 µPa* Sound Power dB at Frequency – Hz re: 10-12W Airflow – m3/s (SCFM) 125 250 500 1000 2000 4000 8000 dBA** dBA 50 0.95 (2000) 85.1 83.0 78.1 80.4 74.6 75.5 66.1 84.1 71.1 75 1.43 (3000) 89.4 84.7 86.1 83.5 78.8 76.8 68.0 88.1 75.0 100 1.89 (4000) 100.1 100.4 92.2 90.7 85.6 80.2 73.6 96.3 83.3 m3 (1000 *Weighted sound pressure dBA in a 28.3 **Based on compressor operating at full speed. 990-5801C-001 ft3) room at 1.5 m (5-ft) distance. 47 ACRD100, ACRD200, ACRD600, and ACRD600P Series Technical Data Dimensions and Weights ACRD100 and ACRD200 Series Cooling Units ) 1070 (42 1991 (78 na2231a ) 300 (12) NOTE: Dimensions are shown in mm (in.). Model Packaged Weight – kg (lb) Unpackaged Weight – kg (lb) ACRD100, ACRD101 221.0 (488.0) 183.0 (404.0) ACRD200, ACRD201 237.1 (522.7) 199.1 (438.0) na2784a NetShelter SX to VX Height Adapter 74.8 ( 2.94) 300 (11 .8) NOTE: Dimensions are shown in mm (in.). 48 990-5801C-001 Technical Data ACRD100, ACRD200, ACRD600, and ACRD600P Series 265.3 na2788a NetShelter SX to 48-U SX Height Adapter (10.44 ) 300 (1 1.8) NOTE: Dimensions are shown in mm (in.). ACRD600 and ACRD600P Series Cooling Units ) 1070 (42.1 600 (23.6) 1991 (78.4) na5811a 2156 (84.9) 879 (34.6 ) Model 990-5801C-001 ) .8 1137 (44 Net Weight – kg (lb) Shipping Weight – kg (lb) ACRD600 402 (886) 447 (986) ACRD601 391 (862) 436 (961) ACRD602 391 (862) 436 (961) ACRD600P 413 (911) 458 (1,010) ACRD601P 402 (886) 447 (986) ACRD602P 402 (886) 447 (986) 49 ACRD100, ACRD200, ACRD600, and ACRD600P Series Technical Data na2445a NetShelter SX to VX Height Adapter 74.8 ( 2.94) 600 (2 3.6) NOTE: Dimensions are shown in mm (in.). NetShelter SX to 48-U SX Height Adapter na2446a 265.3 (10.44 ) 600 (2 3.6) NOTE: Dimensions are shown in mm (in.). 50 990-5801C-001 Technical Data ACRD100, ACRD200, ACRD600, and ACRD600P Series Piping and Electrical Access Locations Top Piping and Power Access Locations—Top View, Looking Down (ACRD100 and ACRD200 Series) REAR—HOT AISLE 88.9 (3.5) 55.1 (2.2) 85.6 (3.4) 154.6 (6.1) 109.7 (4.3) 38.2 (1.5) na2813a 87.6 (3.4) 143.4 (5.6) 42.6 (1.7) 47.8 (1.9) FRONT—COLD AISLE NOTE: Dimensions are shown in mm (in.). Item 990-5801C-001 Description Low voltage wiring input Electrical input Hot gas discharge line (ACRD100 series) Water/glycol out (ACRD200 series) Liquid line (ACRD100 series) Water/glycol in (ACRD200 series) Condensate pump outlet 51 ACRD100, ACRD200, ACRD600, and ACRD600P Series Technical Data Bottom Piping and Power Access Locations—Bottom View, Looking Up (ACRD100 and ACRD200 Series) REAR—HOT AISLE 102 (4.0) 88.9 (3.5) 168.8 (6.6) 122.1 (4.8) 113 (4.4) na2814a 102.1 (4.0) 133.6 (5.3) 55.1 (2.2) FRONT—COLD AISLE NOTE: Dimensions are shown in mm (in.). Item 52 Description Electrical input Low voltage wiring input Liquid line (ACRD100 series) Water/glycol in (ACRD200 series) Condensate pump outlet Hot gas discharge line (ACRD100 series) Water/glycol out (ACRD200 series) 990-5801C-001 Technical Data ACRD100, ACRD200, ACRD600, and ACRD600P Series Top Piping and Power Access Locations—Top View, Looking Down (ACRD600, ACRD600P Series) REAR—HOT AISLE 547 (21.54) 75 (2.95) 73 (2.86) 105 (4.12) 325 (12.78) 380 (14.94) 738 (29.04) 123 (4.84) 558 (21.97) 40 (1.58) na2071a 47 (1.85) FRONT—COLD AISLE NOTE: Dimensions are shown in mm (in.). Item 990-5801C-001 Description Refrigerant discharge line Refrigerant liquid line Trough for communication cables Power connections Humidifier water supply (ACRD600P series only) Condensate drain line outlet 53 ACRD100, ACRD200, ACRD600, and ACRD600P Series Technical Data Bottom Piping and Power Access Locations—Bottom View, Looking Up (ACRD600, ACRD600P Series) REAR—HOT AISLE 480 (18.90) 345 (13.58) 404 (15.91) 893 (35.16) 796 (31.34) 420 (16.54) 199 (7.84) 184 (7.24) 115 (4.53) na5837a 57 (2.25) 140 (5.51) 178 (7.00) FRONT—COLD AISLE NOTE: Dimensions are shown in mm (in.). Item 54 Description Humidifier water supply (ACRD600P series only) Condensate drain line outlet Power connections Communication connections—27.80 mm (1.09 in.) Condensate overflow—50.00 mm (1.97 in.) Refrigerant discharge line Refrigerant liquid line 990-5801C-001 Technical Data ACRD100, ACRD200, ACRD600, and ACRD600P Series ACRD600 and ACRD600P Series BOTTOM PIPING TOP PIPING na2543a LIQUID HOT GAS DX UNIT Item CONDENSER LIQUID HOT GAS CONDENSER RECEIVER RECEIVER DX UNIT Description Pitch in direction of refrigerant flow; 4 mm per m (1/2-in. per 10 ft) Reduction of piping diameter for vertical piping run (if necessary) Shut-off valve Item Description Check valve P-trap S-trap Head pressure control valve Inverted P-trap Pressure relief valve NOTE: All lines are Type L ACR copper tubing. NOTE: Shutoff valves shown nearest to the condenser are provided in receiver kit. NOTE: Route piping through the top or bottom of the InRow DX. NOTE: Trap the vertical discharge line every 6 m (20 ft) to ensure proper oil return. NOTE: The maximum piping run is 91 m (300 ft) equivalent length. Size the piping pursuant to accepted refrigeration practice. NOTE: The condenser can be placed up to 4.5 m (15 ft) below the indoor cooling unit for equivalent line lengths of 8 m (25 ft) or less. For Condensers Mounted Below the Level of the Indoor Unit Piping Equivalent Length – m (ft) Allowable Distance From Bottom of Condenser to Bottom of Indoor Unit* – m (ft) 91 (300) 76 (250) 61 (200) 46 (150) 30 (100) 15 (50) 8 (25) 0.3 (1) 1.5 (5) 2.1 (7) 2.7 (9) 3.3 (11) 3.9 (13) 4.5 (15) *When condenser is installed below unit level, use 7/8 in. pipe for liquid line. NOTE: The condenser can be placed higher than indoor cooling unit but height shall be no more than 27 m (90 ft), regardless of piping length. 990-5801C-001 55 ACRD100, ACRD200, ACRD600, and ACRD600P Series Technical Data na2765a Water-Cooled Bottom Piping (ACRD200 Series) Item Description InRow DX Balancing valve* Strainer, 20 mesh* Gate valve* Hose bib* *Field supplied and field installed 56 990-5801C-001 Technical Data ACRD100, ACRD200, ACRD600, and ACRD600P Series na2766a Glycol-Cooled Bottom Piping (ACRD200 Series) Item Description Expansion tank* Tank fill* Fluid-cooler Airtrol fitting* Temperature and pressure gauges* Air vent* Hose bibs* Gate valve* Balancing valve* Check valve Pump package* Flow switch Strainer, 20 mesh* InRow DX *Field supplied and field installed 990-5801C-001 57 ACRD100, ACRD200, ACRD600, and ACRD600P Series Outdoor Heat Exchanger Data Outdoor Heat Exchanger Data Mechanical Data Air-Cooled Condensers (ACRD100 Series) Connection Size Ambient Temp – °C (°F) Sound Pressure* Air Quantity – l/s (CFM) Fan – Qty. Unit – kW ACCD75214 35.0–40.6 (95.0–105.1) 65 2380 (5,050) 1 ACCD75215 46.0 (114.8) 66 3040 (6,450) ACCD75216 35.0–40.6 (95.0–105.1) 59 ACCD75217 46.0 (114.8) ACCD75218 Model Hot Gas Liquid 1.1 1 1/8 in. 7/8 in. 1 1.1 1 1/8 in. 2140 (4,530) 1 0.8 62 4280 (9,060) 2 35.0–40.6 (95.0–105.1) 59 2140 (4,530) ACCD75219 46.0 (114.8) 62 ACCD75220 35.0–40.6 (95.0–105.1) 59 Capacity Weight – kg (lb) MBH/1°F TD kW/1°C TD 82 (180.0) 2.43 1.28 7/8 in. 118 (260.0) 4.00 2.11 22 mm 18 mm 48 (105.8) 2.35 1.24 1.6 28 mm 22 mm 89 (196.2) 4.30 2.27 1 0.6 22 mm 18 mm 48 (105.8) 2.35 1.24 4280 (9,060) 2 1.3 28 mm 22 mm 89 (196.2) 4.30 2.27 2140 (4,530) 1 0.6 22 mm 18 mm 48 (105.8) 2.35 1.24 *(dbA) at 10 ft and 100% fan speed NOTE: ACCD75220 is CCC certified for use in China. NOTE: ACCD75216, ACCD75217, and ACCD75218 are CMIM compliant. 58 990-5801C-001 Outdoor Heat Exchanger Data ACRD100, ACRD200, ACRD600, and ACRD600P Series Air-Cooled Condensers (ACRD600 Series) Model Ambient Temperature – ° C (°F) Sound Pressure – (dbA) Horizontal Airflow Vertical Airflow Air Quantity – l/ s (CFM) Fan – Qty. Unit – kW ACCD75228 35.0–40.6 (95.0–105.1) 67.2** 65.0** 7780 (16,672) 3 3.13 ACCD75229 46.0 (114.8) 67.2** 64.5** 7488 (16,045) 3 3.19 ACCD75230 35.0–40.6 (95.0–105.1) 67.8** 65.0** 7780 (16,672) 3 3.13 ACCD75231 46.0 (114.8) 67.8** 64.5** 7488 (16,045) 3 3.19 ACCD75232 35.0–46.0 (95.0–114.8) 60.7 56.6 5133 (11,000) 2 1.20 ACCD75232-C 35.0–46.0 (95.0–114.8) 60.7 56.6 5133 (11,000) 2 1.32 ACCD75232-40C*** –40.0–46.0 (–40.0–114.8) 60.7 56.6 5133 (11,000) 2 1.32 ACCD75233-C 35.0–46.0 (95.0–114.8) 60.7 56.6 5133 (11,000) 2 1.44 ACCD75234* 35.0–40.6 (95.0–105.1) 64 59 5400 (11,500) 1 1.45 ACCD75235* 35.0–40.6 (95.0–105.1) 64 59 5400 (11,500) 1 1.45 * Make-to-order. Additional lead times may apply. ** (dbA) is at 3 m. Note: (dbA) is at 5 m unless otherwise noted. *** Minimum working temperature is –40°C (–40°F). NOTE: ACCD75232-C is CMIM compliant. Capacity Connection Size Weight – kg (lb) Model Hot Gas Liquid ACCD75228 7/8 in. 5/8 in. ACCD75229 7/8 in. ACCD75230 MBH/1°F TD kW/1°C TD 218 (480) 5.7 3.0 5/8 in. 230 (509) 7.8 4.1 7/8 in. 5/8 in. 218 (480) 5.7 3.0 ACCD75231 7/8 in. 5/8 in. 230 (509) 7.8 4.1 ACCD75232 22 mm 16 mm 144 (318) 8.3 4.4 ACCD75232-C 22 mm 16 mm 135 (298) 8.3 4.4 ACCD75232-40C 22 mm 16 mm 135 (298) 8.3 4.4 ACCD75233-C 22 mm 16 mm 136 (300) 8.3 4.4 ACCD75234* 1 3/8 in. 1 1/8 in. 250 (550) 10.0 5.3 ACCD75235* 1 3/8 in. 1 1/8 in. 250 (550) 10.0 5.3 * Make-to-order. Additional lead times may apply. ** (dbA) is at 3 m. Note: (dbA) is at 5 m unless otherwise noted. NOTE: ACCD75232-C is CMIM compliant. 990-5801C-001 59 ACRD100, ACRD200, ACRD600, and ACRD600P Series Outdoor Heat Exchanger Data Fluid Coolers (ACRD200 Series) Capacity Ambient Temp – °C (°F) Sound Pressure* Air Quantity – l/s (CFM) Fan – Qty. Unit – kW Connection Size Weight – kg (lb) ACFC75210 40.0 (104.0) 68 4760 (10,100) 2 2.0 1 3/8 in. ACFC75255 35.0 (95.0) 65 2380 (5050) 1 1.0 ACFC75256 35.0 (95.0) 62 4220 (8950) 2 ACFC75257 40.0 (104.0) 56 5500 (11,650) 2 Model MBH/1°F TD kW/1°C TD 205 (450) 3.20 1.69 1 1/8 in. 150 (330) 2.36 1.24 1.6 1 1/2 in. 90 (198) 2.50 1.32 1.4 2 in. 151 (333) 3.30 1.74 *(dbA) at 10 ft and 100% fan speed NOTE: ACFC75257 is CMIM compliant. 60 990-5801C-001 Outdoor Heat Exchanger Data ACRD100, ACRD200, ACRD600, and ACRD600P Series Electrical Data Air-Cooled Condensers (ACRD100 Series) Model Voltage, Phase, Frequency Receiver Model Receiver Qty. FLA* MCA* MOP* ACCD75214 208-240V, 1 ph, 60 Hz ACAC75009 1 4.8 15 15 ACCD75215 208-240V, 1 ph, 60 Hz ACAC75009 2 4.8 15 15 ACCD75216 380-415V, 3 ph, 50 Hz ACAC75009 1 1.35 N/A N/A ACCD75217 380-415V, 3 ph, 50 Hz ACAC75009 1 2.7 N/A N/A ACCD75218 220-240V, 1 ph, 50 Hz ACAC75009 1 3.0 N/A N/A ACCD75219 220-240V, 1 ph, 50 Hz ACAC75009 1 6.0 N/A N/A ACCD75220 220-240V, 1 ph, 50 Hz ACAC75009 1 3.0 N/A N/A * Cells marked N/A indicate that this information is not required because of regional differences in electrical codes. NOTE: ACCD75220 is CCC certified for use in China. NOTE: ACCD75216, ACCD75217, and ACCD75218 are CMIM compliant. Air-Cooled Condensers (ACRD600 Series) Model Voltage, Phase, Frequency Receiver Model Receiver Qty. FLA* MCA* MOP* ACCD75228 208-240 V, 3 ph, 60 Hz ACAC75014 1 N/A 10.7 15 ACCD75229 208-240 V, 3 ph, 60 Hz ACAC75014 1 N/A 10.7 15 ACCD75230 460-480 V, 3 ph, 60 Hz ACAC75014 1 N/A 6.5 15 ACCD75231 460-480 V, 3 ph, 60 Hz ACAC75014 1 N/A 6.5 15 ACCD75232 230 V, 1 ph, 50 Hz ACAC75013 1 6.0 N/A N/A ACCD75232-C 230 V, 1 ph, 50 Hz ACAC75015 1 6.0 N/A N/A ACCD7523240C 230 V, 1 ph, 50 Hz ACAC75015 1 7.0 N/A N/A ACCD75233-C 230 V, 1 ph, 60 Hz ACAC75015 1 6.0 N/A N/A ACCD75234* 208-240 V, 3 ph, 60 Hz ACAC75014 1 6.4 8.8 15 ACCD75235* 460-480 V, 3 ph, 60 Hz ACAC75014 1 2.9 4.0 15 * Make-to-order. Additional lead times may apply. **Cells marked N/A indicate that this information is not required because of regional differences in electrical codes. NOTE: ACCD75232-C is CMIM compliant. 990-5801C-001 61 ACRD100, ACRD200, ACRD600, and ACRD600P Series Outdoor Heat Exchanger Data Fluid Coolers (ACRD200 Series) Voltage, Phase, Frequency FLA* MCA* MOP* ACFC75210 460 V, 3 ph, 60 Hz 2.6 15 15 ACFC75255 480 V, 3 ph, 60 Hz 1.3 15 15 ACFC75256 380-415 V, 3 ph, 50 Hz 2.7 N/A N/A ACFC75257 380-415 V, 3 ph, 50 Hz 2.7 N/A N/A Model * Cells marked N/A indicate that this information is not required because of regional differences in electrical codes. NOTE: ACFC75257 is CMIM compliant. Dimensions ACCD75234, ACCD75235 NOTE: Dimensions are shown in mm (in.). NOTE: Make-to-order. Additional lead times may apply. 2055 (80.90 ) na6253a 1387 ) (54.62 1175 ) (46.24 1472 (57.94 ) 1243 ) (48.92 ACCD75228, ACCD75229, ACCD75230, ACCD75231 NOTE: Dimensions are shown in mm (in.). NOTE: Condensers shown have eight 22-mm (0.875 in.) mounting holes on their lower rails. na5853a 3151 (124.0 6) 1318 (51.88 ) 1317 (51.87 ) 824 ) (32.45 973 (38.3) 1003 ) 3 ( 9.48 62 990-5801C-001 Outdoor Heat Exchanger Data ACRD100, ACRD200, ACRD600, and ACRD600P Series ACCD75232 NOTE: Dimensions are shown in mm (in.). NOTE: Condensers shown have eight 22-mm (0.875 in.) mounting holes on their lower rails. 2167 (85.31 ) 1248.5 ) (49.15 na5854a 700 ) (27.56 1000 (39.37 ) 1025 (40.35 ) 1050 ) 4 ( 1.34 1110 (43.7) ACCD75232-C, ACCD75232-40C, ACCD75233-C NOTE: Dimensions are shown in mm (in.). NOTE: Condensers shown have eight 22-mm (0.875 in.) mounting holes on their lower rails. 2090 (82.28 ) 1344 ) (52.91 na5855a 700 ) 2 ( 7.56 1000 (39.37 ) 990-5801C-001 1030 (40.55 ) 1050 ) (41.34 1110 (43.7) 63 ACRD100, ACRD200, ACRD600, and ACRD600P Series Outdoor Heat Exchanger Data ACCD75214 NOTE: Dimensions are shown in mm (in.). na2891a 958 (37.71) 762 (30.00) 1085 (42.72) ACCD75215 NOTE: Dimensions are shown in mm (in.). na2895a 958 (37.71) 1085 (42.72) 1016 (40.00) ACCD75216, ACCD75218, ACCD75220 NOTE: Dimensions are shown in mm (in.). 1442 (56.77) na2893a 890 (35.04) 900 (35.43) 64 900 (35.43 990-5801C-001 Outdoor Heat Exchanger Data ACRD100, ACRD200, ACRD600, and ACRD600P Series ACCD75217, ACCD75219 NOTE: Dimensions are shown in mm (in.). 2222 (87.48 ) na2896a 890 ) (35.04 1680 (66.14 ) 900 ) (35.43 ACFC75210 NOTE: Dimensions are shown in mm (in.). na2890a 958 ) (37.72 1524 (60.00 ) 1079 ) (42.50 ACFC75255 NOTE: Dimensions are shown in mm (in.). na2899a 958 ) (37.72 762 (30.00 990-5801C-001 ) 1079 ) (42.50 65 ACRD100, ACRD200, ACRD600, and ACRD600P Series Outdoor Heat Exchanger Data ACFC75256 NOTE: Dimensions are shown in mm (in.). 2222 (87.48) na2894a 890 3 ( 5.04) 1680 (66.14) 900 (35.43) ACFC75257 NOTE: Dimensions are shown in mm (in.). 2942 (115.8 3) na2898a 890 ) (35.04 2400 (94.50 66 ) 1260 ) (49.60 990-5801C-001 Worldwide Customer Support Customer support for this or any other product is available at no charge in any of the following ways: • Visit the Schneider Electric Web site to access documents in the Schneider Electric Knowledge Base and to submit customer support requests. - www.schneider-electric.com (Corporate Headquarters) Connect to localized Schneider Electric Web sites for specific countries, each of which provides customer support information. - www.schneider-electric.com/support/ Global support searching Schneider Electric Knowledge Base and using esupport. • Contact the Schneider Electric Customer Support Center by telephone or e-mail. Local, country-specific centers: go to www.schneider-electric.com/support/ contactwww.schneider-electric.com > Support > Operations around the world for contact information. For information on how to obtain local customer support, contact the representative or other distributors from whom you purchased your product. Schneider Electric 35 rue Joseph Monier 92500 Rueil Malmaison France + 33 (0) 1 41 29 70 00 www.schneider-electric.com As standards, specifications, and design change from time to time, please ask for confirmation of the information given in this publication. © 2016 – 2019 Schneider Electric. All rights reserved. 990-5801C-001
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
Download PDF
advertisement