MasterBus – USB interface
USERS MANUAL / GEBRUIKERSHANDLEIDING / BETRIEBSANLEITING
MANUEL D’UTILISATION / MANUAL DE UTILIZACION
MasterBus – USB interface
Communication interface between your PC and the MasterBus network
MASTERVOLT
Snijdersbergweg 93,
1105 AN Amsterdam
The Netherlands
Tel.: +31-20-3422100
Fax.: +31-20-6971006
www.mastervolt.com
ENGLISH:
NEDERLANDS:
DEUTSCH:
FRANÇAIS:
CASTELLANO:
ITALIANO:
PAGE 1
PAGINA 13
SEITE 25
PAGINA 37
PÁGINA 49
PÁGINA 61
Copyright © 2008 Mastervolt, v 2.1 September 2008
CONTENTS - GENERAL INFORMATION
CONTENTS:
v 2.1 September 2008
1
GENERAL INFORMATION............................................................................................................................. 2
2
MASTERBUS.................................................................................................................................................. 3
3
INSTALLATION .............................................................................................................................................. 5
4
USE OF MASTERADJUST SOFTWARE....................................................................................................... 6
5
ADDITIONAL INFORMATION...................................................................................................................... 10
6
TROUBLE SHOOTING ................................................................................................................................. 11
7
SPECIFICATIONS ........................................................................................................................................ 12
1 GENERAL INFORMATION
1.1
USE OF THIS MANUAL
Copyright © 2008 Mastervolt. All rights reserved.
Reproduction, transfer, distribution or storage of part
or all of the contents in this document in any form
without the prior written permission of Mastervolt is
prohibited.
This manual serves as a guideline for the safe and
effective operation, maintenance and possible
correction of minor malfunctions of the MasterBus USB interface.
This manual is valid for the following model:
Description
Part number
MasterBus - USB interface
77030100
Keep this manual at a secure place!
The English version has 12 pages.
1.2
IMPORTANT TO KNOW
Incorrect installation may lead to damage to the
MasterBus-USB interface, the connected Mastervolt
devices and/or the connected PC. Be sure that all
equipment is disconnected from any power source
during installation.
2
1.3
GUARANTEE SPECIFICATIONS
Mastervolt guarantees that this product was built
according to the legally applicable standards and
stipulations. If you fail to act in accordance with the
regulations, instructions and stipulations in this
user’s manual, damage can occur and/or the product
will not fulfil the specifications. This may mean that
the guarantee will become null and void.
IMPORTANT: Additional warranty agreements, like
“Mastervolt
system
warranty”
may
contain
restrictions which forbid resetting of historical data
1.4
LIABILITY
Mastervolt can accept no liability for:
• Consequential damage resulting from the use of
the MasterBus - USB interface and/or the
MasterAdjust software;
• Possible errors in the included manuals and the
consequences of these.
• Use that is inconsistent with the purpose of the
product
September 2008 / MasterBus - USB interface / EN
MASTERBUS
2 MASTERBUS
2.1
WHAT IS MASTERBUS?
All devices that are suitable for
MasterBus are marked by the MasterBus
symbol.
MasterBus is a fully decentralized data network for
communication between the different Mastervolt
system devices. It is a CAN-bus based
communication network which has proven itself as a
reliable bus-system in automotive applications.
MasterBus is used as power management system
for all connected devices, such as the inverter,
battery charger, generator and many more. This
gives the possibility for communication between the
connected devices, for instance to start the
generator when the batteries are low.
MasterBus reduces complexity of electrical systems
by using UTP patch cables. All system components
are simply chained together. Therefore each device
is equipped with two MasterBus data ports. When
two or more devices are connected to each other
through these data ports, they form a local data
network, called the MasterBus. The results are a
reduction of material costs as only a few electrical
cables are needed and less installation time.
EN / MasterBus - USB interface / September 2008
For central monitoring and control of the connected
devices Mastervolt offers a wide range of panels
which show full status information of your electrical
system at a glance and a push of a button. Four
different panels are available, from the small
Mastervision compatible 120 x 65mm LCD screen
up to the full colour MasterView System panel. All
monitoring panels can be used for monitoring,
control and configuration of all connected MasterBus
equipment.
New devices can be added to the existing network in
a very easy way by just extending the network. This
gives the MasterBus network a high degree of
flexibility for extended system configuration, not only
today, but in the future as well!
Mastervolt also offers several interfaces, making
even non-MasterBus devices suitable to operate in
the MasterBus network
For direct communication between the MasterBus
network and a product which is not from Mastervolt,
the Modbus interface is recommended.
CAUTION: Never connect a nonMasterBus device to the MasterBus
network directly! This will void warranty of
all MasterBus devices connected.
3
MASTERBUS
2.2
HOW TO
NETWORK
SET
UP
A
MASTERBUS
Each device that is suitable for the MasterBus
network is equipped with two data ports. When two
or more devices are connected to each other
through these ports, they form a local data network,
called the MasterBus.
Keep the following rules in mind:
The electric power for the network comes from
the connected devices.
At least one device in the network should have
powering capabilities (see specifications).
One powering device can power up to three nonpowering devices.
As all powering devices are galvanically isolated,
multiple powering devices are allowed
Connections between the devices are made by
standard straight UTP patch cables. Mastervolt
can supply these cables. These cables are also
commonly available at computer supply stores.
OK
Figure 3
Do not make ring networks
OK
Figure 1
As with all high speed data networks, MasterBus
needs a terminating device on both ends of the
network
Figure 4
Do not make T-connections in the network
Terminating
device
Terminating
device
OK
Figure 2
4
Figure 5
September 2008 / MasterBus - USB interface / EN
INSTALLATION
3 INSTALLATION
3.1
3.2
CONNECTION
What you need:
; MasterBus-USB interface (included)
; USB connection cable (included)
; MasterBus connection cables (UTP patch
cables) (included, 6m)
… A PC or notebook with Internet connection and a
free USB 2.0 port
See figure 6
• Insert the MasterBus connection cables into the
MasterBus data ports of the MasterBus – USB
interface.
• Connect the USB connection cable between the
MasterBus – USB interface and the USB-port of
the PC or notebook.
1
2
3
4
MASTERADJUST SOFTWARE
Mastervolt MasterAjust software is available as
free to download software on the Mastervolt
website (www.mastervolt.com) Install the
software on the desktop of your PC or notebook.
Start the program by double clicking the
MasterAdjust.exe icon on your desktop
Immediately the USB-MasterBus interface is
detected. This results in a “USB: MasterBus”entry in the left tree-view of the MasterAdjust
software
Now the MasterAdjust software scans the
MasterBus network for connected devices. This
might take a few minutes.
See chapter 4 for details about monitoring and
control functions of the MasterAdjust software
If no devices are displayed, refer to chapter 6 for
trouble shooting.
MasterBus – USB interface
USB connection cable
PC or
notebook
Terminating devices at
each end of the
MasterBus network
Figure 6: Connection of the MasterBus-USB interface
EN / MasterBus - USB interface / September 2008
5
USE OF MASTERADJUST SOFTWARE
4 USE OF MASTERADJUST SOFTWARE
MasterAdjust software can be used for monitoring
and control of devices that are connected to the
MasterBus network. This software is available as
free to download software on the Mastervolt website
(www.mastervolt.com). Features:
• System configuration: to adjust the entire
MasterBus network and all connected devices in
accordance with your personal preferences,
including
programming
of
Event-based
commands
• System Monitor: complete actual overview of
your entire electrical installation
• System logger: data logging of system data
during a longer period for analysis later on.
4.1
IMPORTANT: Invalid adjustment of the MasterAdjust
software may lead to disturbed operation of your
electrical installation. Therefore changes at the
Configuration menu may only be carried out by
qualified installers.
NOTE: As every configuration of the
MasterBus network differs from the other
the displayed data may differ from the
illustrations below. This user’s manual
can not give any specific instructions for
any particular connected device or
electrical installation. Refer to the user’s
manual of the connected device for an
overview of all available readouts and
settings
GENERAL
Click here to change the
displayed language
Detailed information may include the following data
Monitoring, Alarm, History or Configuration
(availability depends on the connected device)
The tree view gives an
overview of the
connected devices.
The MasterAdjust
software may also
recognize other serial
connected devices
(non-MasterBus)
Click on the desired
device to show
detailed information
Click here to close the MasterAdjust software.
Settings are stored in the memory of the selected device.
This means that closing the MasterAdjust software does not affect
the operation of the connected devices
Detailed information of
the selected device
Figure 7
6
September 2008 / MasterBus - USB interface / EN
USE OF MASTERADJUST SOFTWARE
4.2
MONITORING
Click on “Monitoring”
“Monitoring” shows the actual measured
data of the selected device.
Refer to user’s manual of selected
device for explanation of the measured
values.
Figure 8
4.3
ALARMS
Click on the “Alarms” tab
At “Alarms” you can monitor the alarm
function of the selected device.
An alarm may occur when one of the
measured parameters is out of range.
Refer to user’s manual of selected
device for explanation.
The displayed data is read-only
Figure 9
4.4
HISTORY
Click on the “History” tab
To know the history of your electrical
system can be very useful.
It will help you to check if all connected
devices have worked properly in the past.
Most of the displayed data is read-only.
Figure 10
EN / MasterBus - USB interface / September 2008
7
USE OF MASTERADJUST SOFTWARE
4.5
CONFIGURATION
At “Configuration” you can adjust
several parameters of the selected
device in accordance with the
specifications of the electrical
installation.
Click on the “Configuration” tab
The default configuration is optimal for
most installations. In some
applications however, it is desirable to
change the configuration. Refer to the
user’s manual of the connected
device
The configuration is stored in the
memory of the connected device. This
means that closing the MasterAdjust
software will not affect this
configuration
Figure 11
4.6
PROGRAMMING
COMMANDS
OF
EVENT-BASED
One of the main features of MasterBus is the
possibility of programming for interactive operation
the connected devices. This is done by means of
event based commands. See example below where
programming of event based commands is
explained.
4.7
1
See figure 12. In the left tree-view click on the
command source (Example: MasterShunt).
EXAMPLE
If the battery voltage is almost too low, the DC-load
which is connected to output 3 of the DC Switch
must be switched off.
• As the battery voltage is measured by the
MasterShunt, this device is considered as the
command source. (Command source =
MasterShunt)
• “Battery voltage almost too low” is considered to
be the event (Event = Pre low battery)
• The DC Switch is the device that should take
action (switching of a part of the DC-load), and is
therefore considered to be the target. (Target =
DC Switch)
• Event command: at the DC Switch the status of
output 3 should change (Event command =
State 3)
• The status of output 3 should change to Off
(Event action = Off)
8
Follow below steps to program this event based
command:
Figure 12
September 2008 / MasterBus - USB interface / EN
USE OF MASTERADJUST SOFTWARE
2
After selecting the command source, click on the
“Configuration” tab. One of the displayed drop
boxes is named “Event source 1” (figure 13).
5
Next select which parameter must be changed
at the target: Event command. (Example: The
state of switch 3) (figure 16).
Figure 13
3
Click on the drop box and select the event at the
command source that should be the trigger for
an action (Example: Pre low battery) (figure 14).
Figure 16
6
Figure 14
4
Finally select the Event action, which is the
action that should take place (Example: Go off)
(figure 17).
Select the name of the device that should take
action in case of this event: Event target.
(Example: DC switch) (figure 15).
Figure 17
Figure 15
EN / MasterBus - USB interface / September 2008
If you want to continue programming event based
commands, proceed with Event source 2 and follow
the same procedure as described above.
9
ADDITIONAL INFORMATION
5 ADDITIONAL INFORMATION
5.1
ORDERING INFORMATION
Part number
77040000*
77040020
77040050
77040100
77040300
77040600*
77041000
77041500
77042500
77050000
Description
MasterBus terminating device*
MasterBus connection cable (UTP patch cable), 0,2m / 0.6ft
MasterBus connection cable (UTP patch cable), 0,5m / 1.6ft
MasterBus connection cable (UTP patch cable), 1,0m / 3.3ft
MasterBus connection cable (UTP patch cable), 3,0m / 10ft
MasterBus connection cable (UTP patch cable), 6,0m / 20ft
MasterBus connection cable (UTP patch cable), 10m / 33ft
MasterBus connection cable (UTP patch cable), 15m / 49ft
MasterBus connection cable (UTP patch cable), 25m / 82ft
Complete set to assemble UTP patch cables. Delivery includes: 100m / 330ft UTP cable, 50 pcs.
modular jacks and crimping tool
* These parts are standard included with the delivery of the MasterBus - USB interface
Mastervolt can offer a wide range of products for your electrical installation, including an extended program of
components for your MasterBus network or MasterVision switchboard.
See our website www.mastervolt.com for a complete overview of all our products
5.2
EC DECLARATION OF CONFORMITY
Manufacturer
Address
Mastervolt
Snijdersbergweg 93, 1105 AN Amsterdam
The Netherlands
Herewith declares that:
Product:
77030100
MasterBus - USB interface
Is in conformity with the provision of the EC EMC directive 89/336/EEC and amendments 92/31/EEC, 93/68/EEC.
The following harmonised standards have been applied:
Generic emission standard:
EN 50081-1:1992
Generic Immunity standard:
EN 50082-1:1997
Safety directive 2006/95/EC, with the following standard:
Low voltage standard:
EN 60950: 2000
Amsterdam,
P. F. Kenninck,
General Manager MASTERVOLT
10
September 2008 / MasterBus - USB interface / EN
TROUBLE SHOOTING
6 TROUBLE SHOOTING
Contact your local Mastervolt Service Centre if you cannot correct a problem with the aid of the malfunction table
below. See www.mastervolt.com for an extended list of Mastervolt Service Centres.
Failure
No devices can be
found.
Possible cause
If only “My Computer” is shown, the
left hand tree view of the
MasterAdjust software is collapsed.
Error in the wiring.
No terminating device placed at the
ends of the network.
MasterBus network is configured as
a ring network.
T-connections in the MasterBus
network.
One of the
connected devices
can not be found.
Connected device is switched off.
Error in the wiring.
Device not suitable for MasterBus.
Slow or no
communication.
If a setting of a connected device is
changed, communication between
the PC and the connected device.
may take a few seconds.
Error in the wiring.
No terminating device placed at the
ends of the network.
MasterBus network is configured as
a ring network.
T-connections in the MasterBus
network.
Wrong language is
displayed.
Wrong setting of the language at the
MasterAdjust software.
Wrong setting of the language at one
of the connected devices.
EN / MasterBus - USB interface / September 2008
What to do
Click on the
sign in front of “My computer” to
open the tree view.
If green LED on interface is not illuminated or
blinking: check USB connection cable between
the MasterBus – USB interface and the USB-port
of the PC or notebook.
Check the UTP patch cables of the MasterBus
Network.
Check if terminating devices are installed on both
ends of the MasterBus network (see figure 2).
Ring networks are not allowed (see figure 4).
Check the connections of the network.
Check if there are no T-connections in the
network. T-connections are not allowed (see
figure 5).
Switch on connected device.
Check the UTP patch cables.
Check whether the device is suitable for
MasterBus. Maybe the UTP patch cable is
connected to a non-MasterBus connector.
Wait a few seconds.
Check the UTP patch cables.
Check if terminating devices are installed on both
ends of the MasterBus network (see figure 2).
Ring networks are not allowed (see figure 4).
Check the connections of the network.
Check if there are no T-connections in the
network. T-connections are not allowed (see
figure 5).
Click on the “Language” menu and select the
desired language.
Each separate connected device can have its own
language setting. See user’s manual of the
connected device.
11
SPECIFICATIONS
7 SPECIFICATIONS
Manufacturer:
MasterBus – USB interface
77030100
Interface, USB connection cable, UTP patch cable, MasterBus terminating
device, user’s manual
Communication interface between your PC and devices that are connected to
the MasterBus network
Mastervolt Amsterdam the Netherlands
Powering capabilities:
Power consumption:
Din rail mounting:
Weight
Protection degree:
Dimensions:
Yes, when the PC is switched on, it can power up to three non-powering devices
<9mA
Yes, Din rail 30 mm [1.2 inch]
Approx. 80 gr [0.18 lbs]
IP 21
See drawing below
33 [1.3]
32 [1.3]
33 [1.3]
4.0 [0.16]
69 [2.7]
4.0 [0.16]
Function of instrument:
78 [3.1]
Model:
Article number:
Delivery includes:
4,5 [0.18]
6.0 [0.24]
Figure 18:
Dimensions
in mm (inch)
and connectors
= MasterBus connector
USB
= USB connector
USB
Snijdersbergweg 93, 1105 AN Amsterdam, The Netherlands
Tel: + 31-20-3422100
Fax: + 31-20-6971006
Email: info@mastervolt.com
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising