Signamax -065-7708 Hardened Managed PoE Ethernet Switch User's Guide 191 Pages
Below you will find brief information for Hardened Managed PoE Ethernet Switch -065-7708. This switch is a hardened managed PoE Ethernet switch designed for harsh environments, offering full scalability and a wide range of features for network management and security. It delivers robust performance in environments with extreme temperatures, shock, and vibration. This switch is ideal for traffic control systems, industrial applications, and other challenging environments.
advertisement
Signamax
Connectivity Systems
Hardened Managed PoE Ethernet Switch
Model -065-7708
U
S E R
’
S
G
U I D E
Hardened Managed PoE Ethernet Switch
Quick Start Guide
This quick start guide describes how to install and use the
Hardened Managed PoE (Power over Ethernet) Ethernet
Switch. This is the switch of choice for harsh environments constrained by space.
Physical Description
The Port Status LEDs and Power Inputs
LED State
10/100BaseTX
Indication
Steady A valid network connection established.
Link/ACT
Flashing
Transmitting or receiving data.
ACT stands for ACTIVITY.
PoE
Steady Power Device (PD) is connected.
Off Power Device (PD) is disconnected.
10/100/1000BaseTX, 1000BaseSX/LX/BX
Steady A valid network connection established.
Link/ACT
Flashing
Transmitting or receiving data.
ACT stands for ACTIVITY.
User’s Manual 1
SFP
Hardened Managed PoE Ethernet Switch
Steady A valid SFP connection established.
Off Without SFP.
Power Input Assignment
+
47~57VDC
Power
-
Power Ground
Earth Ground
Terminal
Block
User’s Manual 2
Hardened Managed PoE Ethernet Switch
Functional Description
Meets NEMA TS1/TS2 Environmental requirements such as temperature, shock, and vibration for traffic control equipment.
Meets EN61000-6-2 & EN61000-6-4 EMC Generic Standard Immunity for industrial environment.
RS-232 console, Telnet, SNMP v1 & v2c & v3, RMON, Web Browser, and TFTP management.
Supports Command Line Interface in RS-232 console.
Supports 8192 MAC addresses. Provides 2M bits memory buffer.
Supports IEEE802.3af Power over Ethernet (PoE) and IEEE802.3at
PoE+ Power Sourcing Equipment (PSE).
Supports IEEE802.3/802.3u/802.3ab/802.3z/802.3x. Auto-negotiation:
1000Mbps-full-duplex; 10/100Mbps-full/half-duplex; Auto MDI/MDIX.
Provides up to two combo Gigabit ports. SFP socket for Gigabit fiber optic expansion.
Supports digital diagnostics monitoring (DDM)/digital optical monitoring (DOM) functions according to the industry-standard
SFF-8472.
Store-and-forward mechanism. Full wire-speed forwarding rate.
Power Supply: 47~57VDC Terminal Block power input.
Operating voltage and Max. current consumption: 0.37A @ 48VDC,
0.32A @ 55VDC. Power consumption: 17.7W Max.
-40℃ to 75℃ (-40℉ to 167℉) operating temperature range.
Tested for functional operation @ -40℃ to 85℃ (-40℉ to 185℉).
Hardened metal case.
User’s Manual 3
Hardened Managed PoE Ethernet Switch
Console Configuration
Connect to the switch console:
Connect the DB9 straight cable to the RS-232 serial port of the device and the RS-232 serial port of the terminal or computer running the terminal emulation application. Direct access to the administration console is achieved by directly connecting a terminal or a PC equipped with a terminal-emulation program (such as HyperTerminal) to the switch console port.
Configuration settings of the terminal-emulation program:
Baud rate: 115,200bps
Data bits: 8
Parity: none
Stop bit: 1
Flow control: none
Press the “Enter” key. The Command Line Interface (CLI) screen should appear as below:
Logon to Exec Mode (View Mode):
At the “switch_a login:” prompt just type in “root” and press <Enter> to logon to Exec Mode (or View Mode). And the “switch_a>” prompt will show on the screen.
User’s Manual 4
Hardened Managed PoE Ethernet Switch
Logon to Privileged Exec Mode (Enable Mode):
At the “switch_a>” prompt just type in “enable” and press <Enter> to logon to Privileged Exec Mode (or Enable Mode). And the “switch_a#” prompt will show on the screen.
Logon to Configure Mode (Configure Terminal Mode):
At the “switch_a#” prompt just type in “configure terminal” and press
<Enter> to logon to Configure Mode (or Configure Terminal Mode). And the “switch_a(config)#” prompt will show on the screen.
Set new IP address and subnet mask for Switch:
At the “switch_a(config)#” prompt just type in “interface vlan1.1” and press <Enter> to logon to vlan 1 (vlan1.1 means vlan 1). And the
“switch_a(config-if)#” prompt will show on the screen.
Command Syntax: “ip address A.B.C.D/M”. “A.B.C.D” specifies IP address. “M” specifies IP subnet mask. “M”= 8: 255.0.0.0,
16:255.255.0.0, or 24: 255.255.255.0.
For example, At the “switch_a(config-if)#” prompt just type in “ip address
192.168.1.10/24” and press <Enter> to set new IP address
(192.168.1.10) and new IP subnet mask (255.255.255.0) for Switch.
User’s Manual 5
Hardened Managed PoE Ethernet Switch
Web Configuration
Login the switch:
Specify the default IP address (192.168.1.10) of the switch in the web browser. A login window will be shown as below:
User’s Manual 6
Hardened Managed PoE Ethernet Switch
Enter the factory default login ID: root.
Enter the factory default password (no password).
Then click on the “Login” button to log on to the switch.
User’s Manual 7
Hardened Managed PoE Ethernet Switch
User’s Manual 8
Hardened Managed PoE Ethernet Switch
Preface
This manual describes how to install and use the Signamax
Hardened Managed PoE (Power over Ethernet) Ethernet
Switch. This switch introduced here is designed to deliver full scalability with SNMP/RMON web-based management functions by providing:
To get the most out of this manual, you should have an understanding of Ethernet networking concepts.
In this manual, you will find:
Features on the Hardened Managed Ethernet Switch
Illustrative LED functions
Installation instructions
Management Configuration
SNMP, IGMP…
Specifications
User’s Manual 9
Hardened Managed PoE Ethernet Switch
Table of Contents
Quick Start Guide
P
HYSICAL
D
ESCRIPTION
The Port Status LEDs and Power Inputs
F
UNCTIONAL
D
ESCRIPTION
C
ONSOLE
C
ONFIGURATION
W
EB
C
ONFIGURATION
Preface
Table of Contents
Product Overview
H
ARDENED
M
ANAGED
E
THERNET
S
WITCH
P
ACKAGE
C
ONTENTS
P
RODUCT
H
IGHLIGHTS
Basic Features
Management Support
F
RONT
P
ANEL
D
ISPLAY
P
HYSICAL
P
ORTS
S
WITCH
M
ANAGEMENT
Web-based browser interface
Administration console via RS-232 serial port (CLI)
External SNMP-based network management application
Installation
S
ELECTING A
S
ITE FOR THE
S
WITCH
C
ONNECTING TO
P
OWER
DC Terminal Block Power Input
C
ONNECTING TO
Y
OUR
N
ETWORK
Cable Type & Length
Cabling
Switch Management
M
ANAGEMENT
A
CCESS
O
VERVIEW
A
DMINISTRATION
C
ONSOLE
(CLI)
Direct Access
Modem Access
W
EB
M
ANAGEMENT
SNMP-B
ASED
N
ETWORK
M
ANAGEMENT
P
ROTOCOLS
M
ANAGEMENT
A
RCHITECTURE
18
18
18
18
19
19
20
12
12
12
13
13
13
15
15
17
17
17
17
21
21
22
22
23
23
23
24
24
Web-Based Browser Management 25
SNMP & RMON Management 26
User’s Manual 10
1
1
1
3
4
6
9
10
O
VERVIEW
SNMP A
GENT AND
MIB-2 (RFC 1213)
RMON MIB (RFC 2819)
AND
B
RIDGE
MIB (RFC 1493)
RMON Groups Supported
Bridge Groups Supported
Web-Based Browser Management
L
OGGING ON TO THE SWITCH
U
NDERSTANDING THE
B
ROWSER
I
NTERFACE
S
YSTEM
P
ORT
S
WITCHING
T
RUNKING
STP / R
ING
VLAN
Q
O
S
SNMP
802.1
X
O
THER
P
ROTOCOLS
Command Line Console Management
A
DMINISTRATION
C
ONSOLE
Exec Mode (View Mode)
Privileged Exec Mode (Enable Mode)
Configure Mode (Configure Terminal Mode)
S
YSTEM
P
ORT
S
WITCHING
T
RUNKING
STP / R
ING
VLAN
Q
O
S
SNMP
802.1
X
O
THER
P
ROTOCOLS
Specifications
Appendix A
Appendix B
Contact Information
Hardened Managed PoE Ethernet Switch
94
132
146
152
155
164
169
94
95
99
104
108
117
122
131
181
26
27
27
28
28
29
29
31
33
46
52
59
60
70
76
79
84
88
182
183
190
User’s Manual 11
Hardened Managed PoE Ethernet Switch
Product Overview
Hardened Managed Ethernet Switch
Front View
Package Contents
When you unpack the product package, you shall find the items listed below. Please inspect the contents, and report any apparent damage or missing items immediately to your authorized reseller.
•
This Switch
•
User’s Manual
•
RS-232 cable
User’s Manual 12
Hardened Managed PoE Ethernet Switch
Product Highlights
Basic Features
Meets NEMA TS1/TS2 Environmental requirements such as temperature, shock, and vibration for traffic control equipment.
Meets EN61000-6-2 & EN61000-6-4 EMC Generic Standard Immunity for industrial environment.
RS-232 console, Telnet, SNMP v1 & v2c & v3, RMON, Web Browser, and TFTP management.
Supports Command Line Interface in RS-232 console.
Supports 8192 MAC addresses. Provides 2M bits memory buffer.
Supports IEEE802.3af Power over Ethernet (PoE) and IEEE802.3at
PoE+ Power Sourcing Equipment (PSE).
Supports IEEE802.3/802.3u/802.3ab/802.3z/802.3x. Auto-negotiation:
1000Mbps-full-duplex; 10/100Mbps-full/half-duplex; Auto MDI/MDIX.
Provides up to two combo Gigabit ports. SFP socket for Gigabit fiber optic expansion.
Supports digital diagnostics monitoring (DDM)/digital optical monitoring (DOM) functions according to the industry-standard
SFF-8472.
Store-and-forward mechanism. Full wire-speed forwarding rate.
Power Supply: 47~57VDC Terminal Block power input.
Operating voltage and Max. current consumption: 0.37A @ 48VDC,
0.32A @ 55VDC. Power consumption: 17.7W Max.
-40℃ to 75℃ (-40℉ to 167℉) operating temperature range.
Tested for functional operation @ -40℃ to 85℃ (-40℉ to 185℉).
Hardened metal case.
Management Support
VLAN
Port-based VLAN
IEEE802.1Q tagged VLAN
User’s Manual 13
Hardened Managed PoE Ethernet Switch
TRUNKING
Port Trunking
PORT-SECURITY
Per-port programmable MAC address locking
Up to 24 Static Secure MAC addresses per port
IEEE802.1x Port-based Network Access Control
PORT-MIRRORING
Port-mirroring
QOS (IEEE802.1p Quality of Service)
4 priority queues
INTERNETWORKING PROTOCOLS
Bridging:
IEEE802.1s Multiple Spanning Tree
IEEE802.1w Rapid Spanning Tree
IEEE802.1D Spanning Tree compatible
IEEE802.1Q – GVRP
Ring
IP Multicast:
IGMP Snooping
Rate Control
NTP
NETWORK MANAGEMENT METHODS
Console port access via RS-232 cable (CLI, Command Line Interface)
Telnet remote access
SNMP agent:
MIB-2 (RFC1213)
Bridge MIB (RFC1493)
RMON MIB (RFC2819) – statistics, history, alarm and events
VLAN MIB (IEEE802.1Q/RFC2674)
Private MIB
Web browser
TFTP software-upgrade capability
User’s Manual 14
Hardened Managed PoE Ethernet Switch
Front Panel Display
POWER
This LED comes on when the switch is properly connected to power and turned on.
P ort Sta tus LEDs
The LEDs are located on the front panel, displaying status for each respective port. Please refer to the following table for more details.
LED State
10/100BaseTX
Indication
Steady A valid network connection established.
Link/ACT
Flashing
Transmitting or receiving data.
ACT stands for ACTIVITY.
Steady Power Device (PD) is connected.
PoE
Off Power Device (PD) is disconnected.
10/100/1000BaseTX, 1000BaseSX/LX/BX
Steady A valid network connection established.
Link/ACT
Flashing
Transmitting or receiving data.
ACT stands for ACTIVITY.
Steady A valid SFP connection established.
SFP
Off Without SFP.
Physical Ports
The Hardened Managed Ethernet Switch provides:
4-port PoE 10/100BaseTX + 2-port 10/100BaseTX + 2 10/100/1000BaseTX &
Gigabit SFP combo ports Hardened Managed Ethernet Switch
User’s Manual 15
Hardened Managed PoE Ethernet Switch
CONNECTIVITY
RJ-45 connectors on TX ports
Duplex LC connector on SFP 1000BaseSX/LX/BX fiber transceiver
MODE SELECTION
10BaseT full-duplex mode
10BaseT half-duplex mode
100BaseTX full-duplex mode
100BaseTX half-duplex mode
1000BaseT/SX/LX/BX full-duplex mode
Auto-negotiating mode
User’s Manual 16
Hardened Managed PoE Ethernet Switch
Switch Management
Web-based browser interface
The switch also boasts a point-and-click browser-based interface that lets user access full switch configuration and functionality from a
Netscape or Internet Explorer browser.
Administration console via RS-232 serial port (CLI)
The switch provides an onboard serial port, which allows the switch to be configured via a directly connected terminal.
External SNMP-based network management application
The switch can also be configured via SNMP.
User’s Manual 17
Hardened Managed PoE Ethernet Switch
Installation
This chapter gives step-by-step instructions about how to install the switch:
Selecting a Site for the Switch
As with any electric device, you should place the switch where it will not be subjected to extreme temperatures, humidity, or electromagnetic interference. Specifically, the site you select should meet the following requirements:
-The ambient temperature should be between -40℉ to 167℉ (-40℃ to 75
℃).
-The relative humidity should be less than 95 percent, non-condensing.
-Surrounding electrical devices should not exceed the electromagnetic field
(RFC) standards.
-Make sure that the switch receives adequate ventilation. Do not block the ventilation holes on each side of the switch.
Connecting to Power
DC Terminal Block Power Input
Step 1: Connect the DC power cord to the plug-able terminal block on the switch, and then plug it into a standard DC outlet.
Step 2: Disconnect the power cord if you want to shut down the switch.
Back View
User’s Manual 18
Hardened Managed PoE Ethernet Switch
Power Input Assignment
+
Power
-
47~57VDC
Power Ground
Earth Ground
Connecting to Your Network
Terminal
Block
Cable Type & Length
It is necessary to follow the cable specifications below when connecting the switch to your network. Use appropriate cables that meet your speed and cabling requirements.
Cable Specifications
Speed Cable Connector Port
Speed
Half/Full
Duplex
Max.
Distance
10BaseT RJ-45
100BaseTX
1000BaseT
1000BaseSX
1000BaseSX
1000BaseLX
1000BaseBX
RJ-45
RJ-45
Duplex LC
Duplex LC
Duplex LC
Duplex LC
10/20 Mbps 2-pair
UTP/STP
Cat. 3, 4, 5
100 m
100/200
Mbps
2-pair
UTP/STP
Cat. 5
100 m
2000 Mbps 4-pair
UTP/STP
Cat. 5
2000 Mbps MMF
(62.5
μm)
100 m
220 m
2 km
2000 Mbps MMF
(50μm)
550 m
2000 Mbps
SMF (10μm) 10, 20, 50 km
2000 Mbps
SMF (10μm) 20, 40 km
User’s Manual 19
Hardened Managed PoE Ethernet Switch
Cabling
Step 1: First, ensure the power of the switch and end devices are turned off.
<Note> Always ensure that the power is off before any installation.
Step 2: Prepare cable with corresponding connectors for each type of port in use.
Step 3: Consult Cable Specifications Table on previous page for cabling requirements based on connectors and speed.
Step 4: Connect one end of the cable to the switch and the other end to a desired device.
Step 5: Once the connections between two end devices are made successfully, turn on the power and the switch is operational.
User’s Manual 20
Hardened Managed PoE Ethernet Switch
Switch Management
This chapter explains the methods that you can use to configure management access to the switch. It describes the types of management applications and the communication and management protocols that deliver data between your management device (workstation or personal computer) and the system. It also contains information about port connection options.
This chapter covers the following topics:
•
Management Access Overview
•
Key Concepts
•
Key Guidelines for Implementation
•
Web Management Access
•
Administration Console Access
•
SNMP Access
•
Standards, Protocols, and Related Reading
Management Access Overview
The switch gives you the flexibility to access and manage the switch using any or all of the following methods.
The web browser interface and administration console (CLI) support are embedded in the switch software and are available for immediate use.
User’s Manual 21
Hardened Managed PoE Ethernet Switch
Administration Console (CLI)
The administration console is an internal, character-oriented,
Command Line Interface (CLI) for performing system administration such as displaying statistics or changing option settings.
Using this method, you can view the administration console from a terminal, personal computer, Apple Macintosh, or workstation connected to the switch’s console port.
There are two ways to use this management method: direct access or modem access. The following sections describe these methods.
Direct Access
Direct access to the administration console is achieved by directly connecting a terminal or a PC equipped with a terminal-emulation program (such as HyperTerminal) to the switch console port.
When using the management method, configure the terminal-emulation program to use the following parameters (you can change these settings after login):
[DEFAULT PARAMETERS]
♦ 115,200bps
♦ 8 data bits
♦ No parity
♦ 1 stop bit
This management method is often preferred because you can remain connected and monitor the system during system reboots. Also, certain error messages are sent to the serial port, regardless of the interface through which the associated action was initiated. A Macintosh or PC attachment can use any terminal-emulation program for connecting to
User’s Manual 22
Hardened Managed PoE Ethernet Switch
the terminal serial port. A workstation attachment under UNIX can use an emulator such as TIP.
Modem Access
You can access the switch’s administration console from a PC or
Macintosh using an external modem attached to the console port. The switch management program provides Console Port screen, accessible from the Basic Management screen that lets you configure parameters for modem access.
When you have configured the external modem from the administration console, the switch transmits characters that you have entered as output on the modem port. The switch echoes characters that it receives as input on the modem port to the current administration console session.
The console appears to be directly connected to the external modem.
Web Management
The switch provides a browser interface that lets you configure and manage the switch remotely.
After you set up your IP address for the switch, you can access the switch’s web interface applications directly in your web browser by entering the IP address of the switch. You can then use your web browser to list and manage switch configuration parameters from one central location, just as if you were directly connected to the switch’s console port.
SNMP-Based Network Management
You can use an external SNMP-based application to configure and manage the switch. This management method requires the SNMP agent on the switch and the SNMP
Network Management Station to use the same community string. This management method, in fact, uses two community strings: the get community string and the set community string. If the SNMP Network management station only knows the set community string, it can read and write to
User’s Manual 23
Hardened Managed PoE Ethernet Switch
the MIBs. However, if it only knows the get community string, it can only read MIBs. The default get and set community
strings for the switch are public.
Protocols
The switch supports the following protocols:
VIRTUAL TERMINAL PROTOCOLS, SUCH AS TELNET
A virtual terminal protocol is a software program, such as Telnet, that allows you to establish a management session from a Macintosh, a PC, or a UNIX workstation. Because Telnet runs over TCP/IP, you must have at least one IP address configured on the switch before you can establish access to it with a virtual terminal protocol.
<Note> Terminal emulation is different from a virtual terminal protocol in that you must connect a terminal directly to the console port.
SIMPLE NETWORK MANAGEMENT PROTOCOL (SNMP)
SNMP is the standard management protocol for multivendor IP networks.
SNMP supports transaction-based queries that allow the protocol to format messages and to transmit information between reporting devices and data-collection programs. SNMP runs on top of the User Datagram Protocol
(UDP), offering a connectionless-mode service.
Management Architecture
All of the management application modules use the same
Messaging Application Programming Interface (MAPI). By unifying management methods with a single MAPI, configuration parameters set using one method (e.g. console port) are immediately displayed the other management methods (e.g. SNMP agent of web browser).
The management architecture of the switch adheres to the
IEEE open standard. This compliance assures customers that the switch is compatible with, and will interoperate with other solutions that adhere to the same open standard.
User’s Manual 24
Hardened Managed PoE Ethernet Switch
Web-Based Browser Management
The switch provides a web-based browser interface for configuring and managing the switch. This interface allows you to access the switch using a preferred web browser.
This chapter describes how to configure the switch using its web-based browser interface.
User’s Manual 25
Hardened Managed PoE Ethernet Switch
SNMP & RMON Management
This chapter describes the switch’s Simple Network
Management Protocol (SNMP) and Remote Monitoring
(RMON) capabilities.
Overview
RMON is an abbreviation for the Remote Monitoring MIB
(Management Information Base). RMON is a system defined by the Internet Engineering Task Force (IETF) document RFC
2819, which defines how networks can be monitored remotely.
RMONs typically consist of two components: an RMON probe and a management workstation:
- The RMON probe is an intelligent device or software agent that continually collects statistics about a LAN segment or VLAN. The RMON probe transfers the collected data to a management workstation on request or when a pre-defined threshold is reached.
- The management workstation collects the statistics that the RMON probe gathers. The workstation can reside on the same network as the probe, or it can have an in-band or out-of-band connection to the probe.
The switch provides RMON capabilities that allow network administrators to set parameters and view statistical counters defined in MIB-II, Bridge MIB, and RMON MIB. RMON activities are performed at a Network Management Station running an SNMP network management application with graphical user interface.
User’s Manual 26
Hardened Managed PoE Ethernet Switch
SNMP Agent and MIB-2 (RFC 1213)
The SNMP Agent running on the switch manager CPU is responsible for:
- Retrieving MIB counters from various layers of software modules according to the SNMP GET/GET NEXT frame messages.
- Setting MIB variables according to the SNMP SET frame message.
- Generating an SNMP TRAP frame message to the Network Management
Station if the threshold of a certain MIB counter is reached or if other trap conditions (such as the following) are met:
WARM START
COLD START
LINK UP
LINK DOWN
AUTHENTICATION FAILURE
RISING ALARM
FALLING ALARM
TOPOLOGY ALARM
MIB-II defines a set of manageable objects in various layers of the TCP/IP protocol suites. MIB-II covers all manageable objects from layer 1 to layer 4, and, as a result, is the major
SNMP MIB supported by all vendors in the networking industry. The switch supports a complete implementation of
SNMP Agent and MIB-II.
RMON MIB (RFC 2819) and Bridge MIB (RFC
1493)
The switch provides hardware-based RMON counters in the switch chipset. The switch manager CPU polls these counters periodically to collect the statistics in a format that complies with the RMON MIB definition.
User’s Manual 27
Hardened Managed PoE Ethernet Switch
RMON Groups Supported
The switch supports the following RMON MIB groups defined in RFC 2819:
- RMON Statistics Group – maintains utilization and error statistics for the switch port being monitored.
- RMON History Group – gathers and stores periodic statistical samples from the previous Statistics Group.
- RMON Alarm Group – allows a network administrator to define alarm thresholds for any MIB variable. An alarm can be associated with Low
Threshold, High Threshold, or both. A trigger can trigger an alarm when the value of a specific MIB variable exceeds a threshold, falls below a threshold, or exceeds or falls below a threshold.
- RMON Event Group – allows a network administrator to define actions based on alarms. SNMP Traps are generated when RMON Alarms are triggered. The action taken in the Network Management Station depends on the specific network management application.
Bridge Groups Supported
The switch supports the following four groups of Bridge MIB (RFC 1493):
- The dot1dBase Group – a mandatory group that contains the objects applicable to all types of bridges.
- The dot1dStp Group – contains objects that denote the bridge’s state with respect to the Spanning Tree Protocol. If a node does not implement the
Spanning Tree Protocol, this group will not be implemented. This group is applicable to any transparent only, source route, or SRT bridge that implements the Spanning Tree Protocol.
- The dot1dTp Group – contains objects that describe the entity’s transparent bridging status. This group is applicable to transparent operation only and
SRT bridges.
- The dot1dStatic Group – contains objects that describe the entity’s destination-address filtering status. This group is applicable to any type of bridge which performs destination-address filtering.
User’s Manual 28
Hardened Managed PoE Ethernet Switch
Web-Based Browser Management
The switch provides a web-based browser interface for configuring and managing the switch. This interface allows you to access the switch using a preferred web browser.
This chapter describes how to configure the switch using its web-based browser interface.
Logging on to the switch
SWITCH IP ADDRESS
In your web browser, specify the IP address of the switch. Default IP address is 192.168.1.10.
User’s Manual 29
Hardened Managed PoE Ethernet Switch
LOGIN
Enter the factory default login ID: root.
PASSWORD
Enter the factory default password (no password).
Or enter a user-defined password if you followed the instructions later and changed the factory default password.
Then click on the “Login” button to log on to the switch.
User’s Manual 30
Hardened Managed PoE Ethernet Switch
Understanding the Browser Interface
The web browser interface provides groups of point-and-click buttons at the left field of the screen for configuring and managing the switch.
SYSTEM
System Information, System Name/Password, IP Address, ARP Table, Route
Table, Save Configuration, Firmware Upgrade, Reboot, Logout
PORT
Configuration, Port Status, Rate Control, RMON Statistics, Per Port Vlan
Activities
SWITCHING
Bridging, Static MAC Entry, Port Mirroring, PoE, PoE Scheduling
TRUNKING
Port Trunking
User’s Manual 31
Hardened Managed PoE Ethernet Switch
STP / RING
Global Configuration, RSTP Port Setting, MSTP Properties, MSTP Instance
Setting, MSTP Port Setting, Recover-Ring(tm) Capability
VLAN
VLAN Mode Setting, 802.1Q VLAN Setting, 802.1Q Port Setting, Port Based
VLAN
QOS
Global Configuration, 802.1p Priority, DSCP
SNMP
SNMP General Setting, SNMP v1/v2c, SNMP v3
802.1X
Radius Configuration, Port Authentication
OTHER PROTOCOLS
GVRP, IGMP Snooping, NTP
User’s Manual 32
System
Hardened Managed PoE Ethernet Switch
System Information
The System name, Firmware version, System time, MAC address, Default gateway, DNS Server, VLAN ID, IP Address, and IP Subnet Mask of Switch.
User’s Manual 33
Hardened Managed PoE Ethernet Switch
System Name/Password
1. System Name: Click in “System Name” text box. Type a system name if it is blank, or replace the current system name with a new one.
2. Updating Setting: Click “Updating Setting” button to update your settings.
3. Password: Click in “Password” text box. Type a password.
4. Retype Password: Click in “Retype Password” text box. Type the same password in “Password” text box again to verify it.
5. Updating Setting: Click “Updating Setting” button to update your settings.
User’s Manual 34
Hardened Managed PoE Ethernet Switch
IP Address
1. IP Address: Click in “IP Address” text box and type a new address to change the IP Address.
2. IP Subnet Mask: Click in “IP Subnet Mask” text box and type a new address to change the IP Subnet Mask.
3. Submit: Click “Submit” button when you finished these selections.
4. You need to enter the new IP address on the browser and reconnect to the switch after IP or subnet mask are changed.
5. Default Gateway: Click “Default Gateway” drop-down menu to choose
“Disable” or “Enable” from the “Default Gateway” drop-down list to disable or enable Default Gateway Setting for the switch.
Click the text box and type a new address to change the Default
Gateway. (Need to choose “Enable” from the “Default Gateway” drop-down menu.)
6. Submit: Click “Submit” button when you finished Default Gateway.
7. DNS Server: Click “DNS Server” drop-down menu to choose “Disable” or “Enable” from the “DNS Server” drop-down list to disable or enable
DNS Server Setting for the switch.
Click the text box and type a new address to change the DNS Server.
(Need to choose “Enable” from the “DNS Server” drop-down menu.)
User’s Manual 35
Hardened Managed PoE Ethernet Switch
8. Submit: Click “Submit” button when you finished DNS Server.
ARP Table
Click ARP Table to view ARP Table.
User’s Manual 36
Hardened Managed PoE Ethernet Switch
Route Table
Click Route Table to view Route Table.
User’s Manual 37
Hardened Managed PoE Ethernet Switch
Save Configuration
1. Load config from TFTP server:
Click in “TFTP Server” text box and type the TFTP server IP address from where the file will be obtained.
Click in “FILE” text box and type the name of the file that will be obtained.
Click “Load” button to load the file from the TFTP server.
2. Backup config to TFTP server:
Click in “TFTP Server” text box and type the TFTP server IP address to where the file will be backupped.
Click in “FILE” text box and type the name of the file that will be backupped.
Click “Backup” button to backup the file to the TFTP server.
3. Save Configuration: Click “Save Configuration” button to save your configuration settings.
4. Restore Default: Click “Restore Default” button to restore the default settings of the switch.
5. Auto save: Click “Auto save” drop-down menu to choose “Disable” or
“Enable” from the “Auto save” drop-down list to disable or enable Auto save for the switch.
6. Auto save interval (5~65536 sec): Click in “Auto save interval” text box and type a decimal number between 5 and 65536.
7. Submit: Click “Submit” button when you finished Auto save configuration.
User’s Manual 38
Hardened Managed PoE Ethernet Switch
Firmware Upgrade
1. Filename: Click in “Filename” text box and type the name of the file that you intend to upgrade it to the switch.
2. TFTP server IP: Click in “TFTP server IP” text box and type the TFTP server IP address from where the file will be obtained.
3. Upgrade: Click “Upgrade” button to upgrade firmware to the switch.
Please follow the message on the screen during the firmware upgrade process. Do not turn off the power or perform other functions during this period of time. Reboot the switch after completing the upgrade process.
User’s Manual 39
Hardened Managed PoE Ethernet Switch
Please follow the message on the screen during the firmware upgrade process. Do not turn off the power or perform other functions during this period of time.
User’s Manual 40
Hardened Managed PoE Ethernet Switch
User’s Manual 41
Hardened Managed PoE Ethernet Switch
Firmware has been upgraded successfully to the switch. Reboot the switch after completing the upgrade process.
User’s Manual 42
Hardened Managed PoE Ethernet Switch
User’s Manual 43
Hardened Managed PoE Ethernet Switch
Reboot
Reboot: Click “Reboot” button to restart the switch.
User’s Manual 44
Hardened Managed PoE Ethernet Switch
Logout
Logout: Click “Logout” button to logout of the switch.
User’s Manual 45
Port
Hardened Managed PoE Ethernet Switch
Configuration
1. Admin Setting: Click “Admin Setting” drop-down menu to choose “Link down” or “Link up” from the “Admin Setting” drop-down list to disable or enable Admin Setting for the port.
2. Speed: Click “Speed” drop-down menu to change the line speed and duplex settings from the “Speed” drop-down list for the port.
3. Flow control: Click “Flow control” drop-down menu to choose “Disable” or “Enable” from the “Flow control” drop-down list to disable or enable
Flow control for the port.
4. Submit: Click “Submit” button when you finished configurations.
User’s Manual 46
Hardened Managed PoE Ethernet Switch
User’s Manual 47
Hardened Managed PoE Ethernet Switch
Port Status
View the Link Status, Speed, Duplex, and Flow control status for all ports.
SFP Port:
1. View the Detected, Connector, Transceiver, Mode, Wave Length (nm),
Link Length (m), Temperature (C), Vcc (V), Tx_bias (mA), Tx_pow
2.
3.
(dbm), and Rx_pow (dbm) information for SFP ports.
Alarm Situation: View Current Temperature Alarm, Current VCC Alarm,
Current Tx Bias Alarm, Current Tx Power Alarm, and Current Rx
Power Alarm.
Alarm Setting: Click in “Threshold Value” text boxes and type new
Threshold Values for Temp High Alarm, Temp Low Alarm, Temp High
User’s Manual 48
Hardened Managed PoE Ethernet Switch
Warning, Temp Low Warning, VCC High Alarm, VCC Low Alarm, VCC
High Warning, VCC Low Warning, TX Bias High Alarm, TX Bias Low
Alarm, TX Bias High Warning, TX Bias Low Warning, TX Power High
Alarm, TX Power Low Alarm, TX Power High Warning, TX Power Low
Warning, RX Power High Alarm, RX Power Low Alarm, RX Power
High Warning, RX Power Low Warning.
Rate Control
1. Ingress: Click in “Ingress” text box and type a new Rate to change the
Ingress Rate Control for the port.
Rate Values: 64kbps, 128kbps, 192kbps, … , 1792kbps.
2Mbps, 3Mbps, 4Mbps, … , 100Mbps.
104Mbps, 112Mbps, 120Mbps, … , 1000Mbps.
<Note>: M = 1024k.
2. Egress: Click in “Egress” text box and type a new Rate to change the
Egress Rate Control for the port.
Rate Values: 64kbps, 128kbps, 192kbps, … , 1792kbps.
2Mbps, 3Mbps, 4Mbps, … , 100Mbps.
104Mbps, 112Mbps, 120Mbps, … , 1000Mbps.
<Note>: M = 1024k.
3. Update Setting: Click “Update Setting” button when you finished these
Rate Control settings.
User’s Manual 49
Hardened Managed PoE Ethernet Switch
RMON Statistics
Click Port 1 ~ Port 8 to view corresponding RMON Statistics.
User’s Manual 50
Hardened Managed PoE Ethernet Switch
Per Port Vlan Activities
Click Port 1 ~ Port 8 to view corresponding vlan activities.
User’s Manual 51
Switching
Hardened Managed PoE Ethernet Switch
Bridging
1. Aging Time (seconds): Click the text box and type a decimal number as
Bridging Aging Time in seconds.
2. Update Setting: Click “Update Setting” button when you finished Aging
Time settings.
3. Threshold level (0.1-100): Click in “Level” text box and type a decimal number for the port. Need to choose “Broadcast” and/or
“DFL-Multicast“ from “Storm-control enabled type” for the port. DLF
(Destination Lookup Failure).
4. Storm-control enabled type: Choose “Broadcast” and/or “DLF-Multicast” from “Storm-control enabled type” for the port.
5. Update Setting: Click “Update Setting” button when you finished
Threshold level and Storm-control enabled type settings.
User’s Manual 52
Hardened Managed PoE Ethernet Switch
Static MAC Entry
Static-MAC-Entry Forward:
1. Add MAC address: Click in “Add MAC address” text box and type a locked forwarding MAC address for the port.
2. VLAN ID: Click “VLAN ID” drop-down menu and choose a VLAN ID from the “VLAN ID” drop-down list.
3. Delete MAC address: Click “Delete MAC address” drop-down menu and choose a locked forwarding MAC address from the “Delete MAC address” drop-down list to be deleted from the port.
4. Submit: Click “Submit” button when you finished Static-MAC-Entry
Forward settings.
Static-MAC-Entry Discard:
1. Add MAC address: Click in “Add MAC address” text box and type a
MAC address to be discarded for the VLAN.
2. VLAN ID: VLAN ID: Click “VLAN ID” drop-down menu and choose a
VLAN ID from the “VLAN ID” drop-down list.
3. Delete MAC address: Click “Delete MAC address” drop-down menu and choose a MAC address from the “Delete MAC address” drop-down list to be discarded from the VLAN.
4. Submit: Click “Submit” button when you finished Static-MAC-Entry
Discard settings.
User’s Manual 53
Hardened Managed PoE Ethernet Switch
Port Mirroring
1. Mirror From: Choose Mirror From port from Port 1 ~ Port 8.
2. Mirror To: Click “Mirror To” drop-down menu to Choose Mirror To port
(Port 1 ~ Port 8) from “Mirror To” drop-down list.
3. Mirror Mode: Click “Mirror Mode” drop-down menu to Choose “Tx/Rx”,
“Tx”, or “Rx” from “Mirror Mode” drop-down list.
4. Submit: Click “Submit” button when you finished Port Mirroring settings.
User’s Manual 54
Hardened Managed PoE Ethernet Switch
PoE
PoE System Setting:
1. System Power Budget: Click in “System Power Budget” text box and type a new system power budget for Switch.
2. Submit: Click “Submit” button when you finished PoE System Setting.
PoE Port Setting:
1. Enable Mode: Click “Enable Mode” drop-down menu to choose
“Disable”, “Enable”, or “Scheduling” from “Enable Mode” drop-down list to disable, enable, or schedule this port to discover Powered Device (PD) connected to this port.
2. Power Limit by Classification: Check or uncheck “Power Limit by
Classification” to enable or disable this port to provide power to PD according to classification of maximum power range used by PD.
3. Fixed Power Limit (W): First uncheck “Power Limit by Classification” to disable this port to provide power to PD according to classification of maximum power range used by PD. Then click in “Fixed Power Limit
(W)” text box and type a new fixed power limit for this port to provide power to PD.
4. Power Priority: Click “Power Priority” drop-down menu to choose “High”,
“Medium”, or “Low” from the “Power Priority” drop-down list to determine
User’s Manual 55
Hardened Managed PoE Ethernet Switch
power priority of this port.
5. Submit: Click “Submit” button when you finished PoE Port Setting.
Flexible 802.3af High Power PoE Operation: Compatible with the 802.3at
Standard
This Hardened Managed PoE & High Power PoE Ethernet switch is compliant with the 802.3af High Power standard, providing 30W of pure power to power demanding devices such as pan-tilt-zoom (PTZ) network cameras, wireless access bridge/routers and large-screen network video phones et cetera.
This 802.3af High Power switch’s PoE operation with 802.3at based PD is highly versatile and adaptable. Normally, when an 802.3at PD is connected to an 802.3af High Power compliant switch, the switch will detect that the PD’s power requirement is based on class 4 classification outlined in the
IEEE802.3at standard, and only attempt to provide 15.4W of power, which is insufficient to power a 30W 802.3at PD. This is due to the reason that the
30W of power in 802.3af High Power is classified as class 0. However, this
802.3af High Power switch can support 30W 802.3at PD by setting the switch explicitly to provide a fixed rate of 30W power to 30W 802.3at PD.
1. Power Limit by Classification: Uncheck “Power Limit by Classification” to disable Port 1 ~ Port 4 to provide power to 30W 802.3at PD according to classification of maximum power range used by PD.
2. Fixed Power Limit(W): Click in “Fixed Power Limit(W)” text box and type a new fixed power limit 0W for Port 1 ~ Port 4 to provide power to 30W
802.3at PD.
3. OK: Click “OK” button to update your settings.
User’s Manual 56
Hardened Managed PoE Ethernet Switch
User’s Manual 57
Hardened Managed PoE Ethernet Switch
PoE Scheduling
First click on “Switching” from main menu. Then click on “PoE” from
“Switching”. In PoE Port Setting, click “Enable Mode” drop-down menu to choose “Scheduling” from “Enable Mode” drop-down list to schedule this port to discover Powered Device (PD) connected to this port.
PoE Per Port Scheduling:
1. Port: Click “Port” drop-down menu to choose a port from “Port” drop-down list and configure PoE scheduling to this port.
2. Submit: Click “Submit” button when you finished PoE Scheduling for this port.
User’s Manual 58
Trunking
Hardened Managed PoE Ethernet Switch
Port Trunking
Static Channel Group:
1. Trunk 1: Click Port 1 ~ Port 6 to assign ports to Trunk 1. (Maximum 4 ports per Trunk.)
GE Trunking:
1. Trunk 3: Check “Static” or “Disable” to enable or disable Trunk 3 for
Gigabit Ethernet ports.
2. Submit: Click “Submit” button when you finished Port Trunking settings.
User’s Manual 59
STP / Ring
Hardened Managed PoE Ethernet Switch
Global Configuration
1. Spanning Tree Protocol: Click “Spanning Tree Protocol” drop-down menu to Choose “Enable” or “Disable” from “Spanning Tree Protocol” drop-down list to enable or disable Spanning Tree Protocol.
2. Bridge Priority (0..61440): Click in “Bridge Priority” text box and type a decimal number between 0 and 61440.
3. Hello Time (sec) (1..9): Click in “Hello Time” text box and type a decimal number between 1 and 9.
4. Max Age (sec) (6..28): Click in “Max Age” text box and type a decimal number between 6 and 28.
5. Forward Delay (sec) (4..30): Click in “Forward Delay” text box and type a decimal number between 4 and 30.
User’s Manual 60
Hardened Managed PoE Ethernet Switch
6. STP Version: Click “STP Version” drop-down menu to choose “MSTP”,
“RSTP” or “STP compatible” from “STP Version” drop-down list.
7. Update Setting: Click “Update Setting” button when you finished Global
Configuration.
RSTP Port Setting
1. STP Version: Click “STP Version” drop-down menu to choose “RSTP” from “STP Version” drop-down list.
2. Port: Click “Port” drop-down menu to choose Port 1 ~ Port 8 from “Port” drop-down list.
3. Priority(Granularity 16): Click in “Priority” text box and enter a value between 0 and 240 to set the priority for the port. A higher priority will designate the port to forward packets first. A lower number denotes a higher priority. This entry must be divisible by 16. The default priority setting is 128.
4. Admin. Path Cost: Click in “Admin. Path Cost” text box and enter a value between 0 and 2000000 to set the Admin. Path Cost for the port. 0 (auto)
- Setting 0 for the Admin. Path Cost will automatically set the speed for forwarding packets to the port for optimal efficiency. Default port cost:
100Mbps port = 200000. Gigabit port = 20000.
5. Point to Point Link: Click “Point to Point Link” drop-down menu to
Choose “Enable” or “Disable” from “Point to Point Link” drop-down list to enable or disable Point to Point Link for the port.
6. Edge Port: Click “Edge Port” drop-down menu to Choose “Enable”,
“Disable”, or “Auto” from “Edge Port” drop-down list to set Enable,
User’s Manual 61
Hardened Managed PoE Ethernet Switch
Disable, or Auto Edge Port for the port.
7. Update Setting: Click “Update Setting” button when you finished RSTP
Port Setting.
User’s Manual 62
Hardened Managed PoE Ethernet Switch
MSTP Properties
1. STP Version: Click “STP Version” drop-down menu to choose “MSTP” from “STP Version” drop-down list.
2. Region Name: Click in “Region Name” text box to create an MST region and specify a name to it. MST bridges of a region form different spanning trees for different VLANs. By default, each MST bridge starts with the region name as its bridge address. This means each MST bridge is a region by itself, unless specifically added to one.
3. Revision Level: Click in “Revision Level” text box to specify the number for configuration information. The default value of revision number is 0.
4. Max Hops: Click in “Max Hops” text box to specify the maximum allowed hops for BPDU in an MST region. This parameter is used by all the instances of the MST. Specifying the max hops for a BPDU prevents the messages from looping indefinetely in the network. When a bridge receives a MST BPDU that has exceeded the allowed max-hops, it discards the BPDU.
5. Update Setting: Click “Update Setting” button when you finished MSTP
Properties setting.
User’s Manual 63
Hardened Managed PoE Ethernet Switch
User’s Manual 64
Hardened Managed PoE Ethernet Switch
MSTP Instance Setting
VLAN Instance Configuration
1. VLAN Instance Configuration: Click “VLAN Instance Configuration” button. The “VLAN Instance Configuration” window appears.
2. VLAN ID: Click “VLAN ID” drop-down menu to choose VLAN from
“VLAN ID” drop-down list to simultaneously add multiple VLANs for the corresponding instance of a bridge.
3. Instance ID (1..15): Click in “Instance ID” text box to specify the instance
ID.
4. Update Setting: Click “Update Setting” button when you finished VLAN
Instance Configuration.
Included VLANs
1. Instance ID: Click “Instance ID” drop-down menu to choose instance ID from “Instance ID” drop-down list.
2. Included VLAN: Click “Included VLAN” drop-down menu to choose
VLAN from “Included VLAN” drop-down list.
Instance Setting
1. Bridge Priority (0..61440): Click in “Bridge Priority” text box to set the bridge priority for an MST instance to the value specified. The lower the priority of the bridge, the better the chances are the bridge becoming a
User’s Manual 65
Hardened Managed PoE Ethernet Switch
root bridge or a designated bridge for the LAN.
2. Update Setting: Click “Update Setting” button when you finished VLAN
Instance Configuration.
User’s Manual 66
Hardened Managed PoE Ethernet Switch
MSTP Port Setting
Port Instance Configuration
1. Instance ID: Click “Instance ID” drop-down menu to choose instance ID from “Instance ID” drop-down list.
2. Click Port 1 ~ Port 8 to assign ports to the corresponding instance ID.
3. Update Setting: Click “Update Setting” button when you finished Port
Instance Configuration.
Instance ID
1. Instance ID: Click “Instance ID” drop-down menu to choose instance ID from “Instance ID” drop-down list.
MSTP Port Configuration
1. Port: Click “Port” drop-down menu to choose port from “Port” drop-down list.
2. Priority(Granularity 16): Click in “Priority” text box to set the port priority for a bridge group. The Multiple Spanning Tree Protocol uses port priority as a tiebreaker to determine which port should forward frames for a particular instance on a LAN, or which port should be the root port for an instance. A lower value implies a better priority. In the case of the
User’s Manual 67
Hardened Managed PoE Ethernet Switch
same priority, the interface index will serve as the tiebreaker, with the lower-numbered interface being preferred over others. The permitted range is 0-240. The priority values can only be set in increments of 16.
3. Admin. Path Cost: Click in “Admin. Path Cost” text box to set the cost of a path associated with an interface.
4. Update Setting: Click “Update Setting” button when you finished MSTP
Port Setting.
Recover-Ring(tm) Capability
Ring state
1. Click “Ring state” drop-down menu from “Ring state” drop-down list to choose “Enable” or “Disable” to enable or disable Ring state.
2. Update Setting: Click “Update Setting” button when you finished Ring state setting.
Set ring port
1. Ring port 1: Click “Ring port 1” drop-down menu to choose Ring port 1 from “Ring port 1” drop-down list.
2. Ring port 2: Click “Ring port 2” drop-down menu to choose Ring port 2 from “Ring port 2” drop-down list.
User’s Manual 68
Hardened Managed PoE Ethernet Switch
3. Update Setting: Click “Update Setting” button when you finished Set ring port.
User’s Manual 69
VLAN
Hardened Managed PoE Ethernet Switch
VLAN Mode Setting
1. VLAN Mode Setting: Click “VLAN Mode Setting” drop-down menu to
Choose “Tag-based VLAN” or “Port-based VLAN” from “VLAN Mode
Setting” drop-down list.
2. Submit: Click “Submit” button when you finished VLAN Mode Setting.
User’s Manual 70
Hardened Managed PoE Ethernet Switch
User’s Manual 71
Hardened Managed PoE Ethernet Switch
802.1Q VLAN Setting
Add VLAN:
1. 802.1Q VLAN Setting: Click “802.1Q VLAN Setting”. The “VLAN Setting” window appears.
2. Add VLAN: Click “Add VLAN” button to create a new VLAN from “VLAN
Setting” window.
3. VLAN ID(2-4094): Click in the “VLAN ID” textbox and specify a new
VLAN ID number from 2 ~ 4094.
4. VLAN Name: Click in the “VLAN Name” textbox and type a name for this newly created VLAN.
Add port to or delete port from VLAN:
1. VLAN Member: Choose the port to be added to or deleted from the
VLAN.
2. Tag or Untag: Click “Tag or Untag” drop-down menu to Choose “Tag” or
“Untag” from “Tag or Untag” drop-down list for a “Hybrid” port.
3. Submit: Click “Submit” button when you finished VLAN setting.
Delete VLAN:
1. 802.1Q VLAN Setting: Click “802.1Q VLAN Setting”. The “VLAN Setting” window appears.
User’s Manual 72
Hardened Managed PoE Ethernet Switch
2. Delete VLAN: Click “Delete VLAN” button.
3. Select a VLAN ID: Click “Select a VLAN ID” drop-down menu from
“Select a VLAN ID” drop-down list to choose the VLAN to be deleted.
4. Submit: Click “Submit” button when you finished VLAN setting.
802.1Q Port Setting
1. 802.1Q Port Setting: Click “802.1Q Port Setting”. The “VLAN Port
Setting” window appears.
2. Mode: Click “Mode” drop-down menu to Choose “Access”, “Trunk”, or
“Hybrid” from “Mode” drop-down list for the port. The port will be Tag port if you choose “Trunk” Mode for the port. And the port will be Tag or
Untag port if you choose “Hybrid” Mode for the port.
3. PVID: Click in the “PVID” textbox and specify a new PVID number for the port.
4. Update Setting: Click “Update Setting” button when you finished VLAN
Port Setting.
User’s Manual 73
Hardened Managed PoE Ethernet Switch
Port Based VLAN
1. VLAN: Choose the port to be added to or deleted from the VLAN.
2. Select all: Click “select all” button to choose Port 1 ~ Port 8 all to be added to the VLAN.
3. Delete all: Click “delete all” button to choose Port 1 ~ Port 8 all to be deleted from the VLAN.
User’s Manual 74
Hardened Managed PoE Ethernet Switch
4. Submit: Click “Submit” button when you finished Port Based VLAN setting.
User’s Manual 75
QoS
Hardened Managed PoE Ethernet Switch
Global Configuration
1. QoS: Click “QoS” drop-down menu from “QoS” drop-down list to choose
“Enable” or “Disable” to enable or disable QoS.
2. Trust: Enable or disable the switch port to trust the CoS (Class of
Service) labels of all traffic received on that port. Enable or disable a routed port to trust the DSCP (Differentiated Service Code Point) labels of all traffic received on that port.
3. Policy: Choose “Strict Priority(Queue3) + WRR(Queue0-2)” or
“WRR(Queue0-3)”. A strict priority queue is always emptied first. The queues that are used in the WRR (Weighted Round Robin) are emptied in a round
−robin fashion, and you can configure the weight for each queue.
4. Weighted Round Robin: Click in the “Weight(1~55)” textbox and specify a new number from 1 ~ 55 for Queue 0 ~ 3.
5. Submit: Click “Submit” button when you finished Global Configuration.
User’s Manual 76
Hardened Managed PoE Ethernet Switch
802.1p Priority
1. Priority: Click “Priority” drop-down menu from “Priority” drop-down list to choose 0 ~ 3 for VLAN Priority 0 ~ 7.
2. Submit: Click “Submit” button when you finished 802.1p priority.
User’s Manual 77
Hardened Managed PoE Ethernet Switch
DSCP
1. Priority: Click “Priority” drop-down menu from “Priority” drop-down list to choose 0 ~ 3 for DSCP Priority 0 ~ 63.
2. Submit: Click “Submit” button when you finished DSCP.
User’s Manual 78
SNMP
Hardened Managed PoE Ethernet Switch
SNMP General Setting
1. SNMP Status: Click “SNMP Status” drop-down menu from “SNMP
Status” drop-down list to choose “Enable” or “Disable” to enable or disable SNMP.
2. Description: Click in the “Description” textbox and specify a new description for SNMP.
3. Location: Click in the “Location” textbox and specify a new location for
SNMP.
4. Contact: Click in the “Contact” textbox and specify a new contact for
User’s Manual 79
Hardened Managed PoE Ethernet Switch
SNMP.
5. Trap Community Name: For each “Trap Community Name”, Click in the
“Trap Community Name” textbox and specify a trap community name.
6. Trap Host IP Address: For each “Trap Host IP Address”, Click in the
“Trap Host IP Address” textbox and specify a trap host IP address.
7. Link Down Trap: Click “Link Down Trap” drop-down menu from “Link
Down Trap” drop-down list to choose “Enable” or “Disable” to enable or disable link down trap.
8. Link Up Trap: Click “Link Up Trap” drop-down menu from “Link Up Trap” drop-down list to choose “Enable” or “Disable” to enable or disable link up trap.
9. Update Setting: Click “Update Setting” button when you finished SNMP
General Setting.
SNMP v1/v2c
1. Get Community Name: Click in the “Get Community Name” textbox and specify a get community name.
2. Set Community Name: Click in the “Set Community Name” textbox and specify a set community name.
3. Update Setting: Click “Update Setting” button when you finished SNMP
V1/V2c Setting.
User’s Manual 80
Hardened Managed PoE Ethernet Switch
User’s Manual 81
Hardened Managed PoE Ethernet Switch
SNMP v3
Add User:
1. Add User: Click “Add User” button. The “SNMP V3 Setting” window appears.
2. SNMP Version: Click “SNMP Version” drop-down menu from “SNMP
Version” drop-down list to choose “SNMPv3 No-Auth”, “SNMPv3
Auth-MD5”, “SNMPv3 Auth-SHA”, “SNMPv3 Priv Auth-MD5”, or
“SNMPv3 Priv Auth-SHA”.
SNMPv3 No-Auth: Add a user using SNMP v3 without authentication.
SNMPv3 Auth-MD5: Add a user using SNMP v3 with authentication.
Click in the “Auth. Password” textbox and specify an authentication password.
SNMPv3 Auth-SHA: Add a user using SNMP v3 with authentication.
Click in the “Auth. Password” textbox and specify an authentication password.
SNMPv3 Priv Auth-MD5: Add a user using SNMP v3 with authentication and privacy. Click in the “Auth. Password” textbox and specify an authentication password. Click in the “Privacy
PassPhrase” textbox and specify a privacy pass phrase.
SNMPv3 Priv Auth-SHA: Add a user using SNMP v3 with authentication and privacy. Click in the “Auth. Password” textbox and specify an authentication password. Click in the “Privacy
User’s Manual 82
Hardened Managed PoE Ethernet Switch
PassPhrase” textbox and specify a privacy pass phrase.
3. User Name: Click in the “User Name” textbox and specify a user name for user using SNMP v3.
4. Access Mode: Click “Access Mode” drop-down menu from “Access
Mode” drop-down list to choose “Read Only” or “Read/Write”.
Read Only: Add a user using SNMP v3 with read-only access mode.
Read/Write: Add an user using SNMP v3 with read-write access mode
5. Submit: Click “Submit” button when you finished SNMP V3 Setting.
Delete User:
1. Delete User: Click “Delete User” button. The “Select User Name” window appears.
2. Select User Name: Click “Select User Name” drop-down menu from
“Select User Name” drop-down list to choose the user to be deleted from using SNMP v3.
3. Submit: Click “Submit” button when you finished user deletion.
User’s Manual 83
802.1x
Hardened Managed PoE Ethernet Switch
Radius Configuration
1. Radius Status: Click “Radius Status” drop-down menu from “Radius
Status” drop-down list to choose “Enable” or “Disable” to globally enable or disable authentication.
2. Update Setting: Click “Update Setting” button when you finished Radius
Status Setting.
User’s Manual 84
Hardened Managed PoE Ethernet Switch
Add Radius:
1. Add Radius: Click “Add Radius” button. The “Radius Server Setting” window appears.
2. Radius Server IP: Click in the “Radius Server IP” textbox and specify the
IP address of the remote radius server host.
3. Radius Server Port: Click in the “Radius Server Port” textbox and specify the UDP destination port for authentication requests. The host is not used for authentication if set to 0.
4. Secret Key: Click in the “Secret Key” textbox and specify the authentication and encryption key for all radius communications between the Switch and radius server. This key must match the encryption used on the radius daemon. All leading spaces are ignored, but spaces within and at the end of the key are used. If spaces are used in the key, do not enclose the key in quotaion marks unless the quotation marks themselves are part of the key.
5. Timeout <1-1000>: Click in the “Timeout” textbox and specify the time interval (in seconds) that the Switch waits for the radius server to reply before retransmitting. Enter a value in the range 1 to 1000.
6. Retransmit <1-100>: Click in the “Retransmit” textbox and specify the number of times a radius request is resent to a server if that server is not responding or responding slowly. Enter a value in the range 1 to 100.
7. Submit: Click “Submit” button when you finished Radius Server Setting.
User’s Manual 85
Hardened Managed PoE Ethernet Switch
Delete Radius:
1. Delete Radius: Click “Delete Radius” button. The “Select Radius Server
IP” window appears.
2. Select Radius Server IP: Click “Select Radius Server IP” drop-down menu from “Select Radius Server IP” drop-down list to choose the IP address of the remote radius server host to be deleted.
3. Submit: Click “Submit” button when you finished radius server deletion.
User’s Manual 86
Hardened Managed PoE Ethernet Switch
Port Authentication
1. Interface: Click “Interface” drop-down menu from “Interface” drop-down list to choose the port to be set port authentication.
2. Authentication State: Click “Authentication State” drop-down menu from
“Authentication State” drop-down list to choose “Enable” or “Disable” to enable or disable authentication state.
3. Port Control: Click “Port Control” drop-down menu from “Port Control” drop-down list to choose “Auto”, “Force Authorized”, or “Force
Unauthorized” to force a port state. “Auto” specifies to enable authentication on port. “Force Authorized” specifies to force a port to always be in an authorized state. “Force Unauthorized” specifies to force a port to always be in an unauthorized state.
4. Periodic Reauthentication: Click “Periodic Reauthentication” drop-down menu from “Periodic Reauthentication” drop-down list to choose
“Enable” or “Disable” to enable or disable periodic reauthentication.
5. Reauthentication Period <1-4294967295>: Click in the
“Reauthentication Period” textbox and specify the seconds between reauthorization attempts. The default time is 3600 seconds.
6. Update Setting: Click “Update Setting” button when you finished port authentication setting.
User’s Manual 87
Other Protocols
Hardened Managed PoE Ethernet Switch
GVRP
GVRP Global Setting:
1. GVRP: Click “GVRP” drop-down menu from “GVRP” drop-down list to choose “Enable” or “Disable” to enable or disable GVRP (GARP VLAN
Registration Protocol).
User’s Manual 88
Hardened Managed PoE Ethernet Switch
2. Dynamic VLAN creation: Click “Dynamic VLAN creation” drop-down menu from “Dynamic VLAN creation” drop-down list to choose “Enable” or “Disable” to enable or disable Dynamic VLAN creation. GARP
(Generic Attribute Registration Protocol) provides IEEE802.1Q compliant VLAN pruning and dynamic VLAN creation on IEEE802.1Q trunk ports.
3. Update Setting: Click “Update Setting” button when you finished GVRP
Global Setting.
Per port setting (include LAG):
1. GVRP: Click “GVRP” drop-down menu from “GVRP” drop-down list to choose “Enable” or “Disable” to enable or disable GVRP for the port.
2. GVRP applicant: Click “GVRP applicant” drop-down menu from “GVRP applicant” drop-down list to choose “Active” or “Normal” to the port.
Ports in the GVRP active applicant state send GVRP VLAN declarations when they are in the STP (Spanning Tree Protocol) blocking state, which prevents the STP bridge protocol data units (BPDUs) from being pruned from the other port. Ports in the GVRP normal applicant state do not declare GVRP VLANs when in the STP blocking state.
3. GVRP registration: Click “GVRP registration” drop-down menu from
“GVRP registration” drop-down list to choose “Enable” or “Disable” to enable or disable GVRP registration to the port. Configuring an
IEEE802.1Q trunk port in registration mode allows dynamic creation (if dynamic VLAN creation is enabled), registration, and deregistration of
VLANs on the trunk port.
4. Update Setting: Click “Update Setting” button when you finished Per port setting.
User’s Manual 89
Hardened Managed PoE Ethernet Switch
IGMP Snooping
1. IGMP mode: Click “IGMP mode” drop-down menu from “IGMP mode” drop-down list to choose “Disable”, “Passive”, or “querier” for the switch.
Disable: Disable IGMP on the switch. Passive: The switch with only multicast-data-forwarding capability. Querier: The switch acts as the querier for the network. There is only one querier on a network at any time.
2. Update Setting: Click “Update Setting” button when you finished IGMP mode settings.
3. VLAN ID: Click “VLAN ID” drop-down menu from “VLAN ID” drop-down list to choose the VLAN under configuration for the switch.
4. IGMP version: Click “IGMP version” drop-down menu from “IGMP version” drop-down list to choose “1”, “2”, or “3” for the switch.
5. Fast-leave: Click “fast-leave” drop-down menu from “fast-leave” drop-down list to choose “Enable” or “Disable” for the switch. Enable this function will allow members of a multicast group to leave the group immediately when an IGMP Leave Report Packet is received by the
Switch.
IGMP querier:
1. Query-interval: Click in the “query-interval” textbox and specify a new number from 1 ~ 18000. The query-interval field is used to set the time
(in seconds) between transmitting IGMP queries. Entries between 1 and
User’s Manual 90
Hardened Managed PoE Ethernet Switch
18000 seconds are allowed. Default = 125.
2. Max-response-time: Click in the “max-response-time” textbox and specify a new number from 1 ~ 240. This determines the maximum amount of time in seconds allowed before sending an IGMP response report. The max-response-time field allows an entry between 1 and 240
(seconds). Default = 10.
IGMP passive snooping:
1. Report suppression: Click “report suppression” drop-down menu from
“report suppression” drop-down list to choose “Enable” or “Disable” for the switch. Use this command to enable report suppression for IGMP version 1 and version 2. Report suppression does not apply to IGMP version 3, and is turned off by default for IGMP version 1 and IGMP version 2 reports. The switch uses IGMP report suppression to forward only one IGMP report per multicast router query to multicast devices.
When IGMP router suppression is enabled, the switch sends the first
IGMP report from all hosts for a group to all the multicast routers. The switch does not send the remaining IGMP reports for the group to the multicast routers. This feature prevents duplicate reports from being sent to the multicast devices.
2. Update Setting: Click “Update Setting” button when you finished IGMP
Snooping.
User’s Manual 91
Hardened Managed PoE Ethernet Switch
NTP
Adjust RTC Time:
1. Click in textbox and specify the Year, Month, Day, Hour, Minute, and
Second.
2. Update Setting: Click “Update Setting” button when you finished Adjust
RTC Time.
NTP Setting:
1. NTP Status: Click “NTP Status” drop-down menu from “NTP Status” drop-down list to choose “Enable” or “Disable” to enable or disable NTP for the Switch.
2. NTP Server (IP Address or Domain name): Click in the “NTP Server” textbox and specify the IP address or Domain name of NTP server.
3. Sync Time: Click “Sync Time” button to synchronize time with NTP
User’s Manual 92
Hardened Managed PoE Ethernet Switch
server.
4. Time Zone: Click “Time Zone” drop-down menu from “Time Zone” drop-down list to set time zone.
5. Polling Interval (1-10080 min): Click in the “Polling Interval” textbox and specify the polling interval.
6. Update Setting: Click “Update Setting” button when you finished NTP
Setting.
Daylight Saving Setting:
1. Daylight Saving Mode: Click "Daylight Saving Mode" drop-down menu from "Daylight Saving Mode" drop-down list to choose "Disable",
"Weekday", or "Date" to choose disable, weekday, or date daylight saving for the Switch.
2. Time Set Offset (1-1440 min): Click in the "Time Set Offset" textbox and specify the offset time of daylight saving. For example enter 60 for one hour offset.
3. Name of Daylight Saving Timezone: Click in the "Name of Daylight
Saving Timezone" textbox and specify the name of daylight saving timezone. This can be any given name in 14-character alpha-numericals.
Enter the name of Daylight Saving time zone using the following example:
EDT - East Daylight Saving Time Zone.
CDT - Central Daylight-Saving Time Zone.
MDT - Mountain Daylight-Saving Time Zone.
PDT - Pacific Daylight-Saving Time Zone.
ADT - Alaska Daylight-Saving Time Zone.
4. Weekday: Specify the daylight saving period.
•
Month: Click "Month" drop-down menu from "Month" drop-down list to choose from January to December.
•
Week: <1-5> Specifies starting/ending week of daylight savings time.
•
Day: Click "Day" drop-down menu from "Day" drop-down list to choose from Sunday to Saturday.
•
Hour: <0-23> Specifies from 0 to 23.
•
Minute: <0-59> Specifies from 0 to 59.
5. Date: Specify the daylight saving period.
•
Month: Click "Month" drop-down menu from "Month" drop-down list to choose from January to December.
•
Day: <1-31> Specifies from 1 to 31.
•
Hour: <0-23> Specifies from 0 to 23.
•
Minute: <0-59> Specifies from 0 to 59.
6. Update Setting: Click "Update Setting" button when you finished
Daylight Saving Setting.
<Note> The “Week”, “Hour”, “Minute”, and “Day” fields would not accept the alphabetic characters (Like Jan, Feb, sun, mon). They only accept the two digit numbers (0 throught 9).
User’s Manual 93
Hardened Managed PoE Ethernet Switch
Command Line Console Management
The switch provides a command line console interface for configuration purposes. The switch can be configured either locally through its RS-232 port or remotely via a Telnet session. For the later, you must specify an IP address for the switch first.
This chapter describes how to configure the switch using its console by Commend Line.
Administration Console
Connect the DB9 straight cable to the RS-232 serial port of the device to the
RS-232 serial port of the terminal or computer running the terminal emulation application.
Direct access to the administration console is achieved by directly connecting a terminal or a PC equipped with a terminal-emulation program (such as
HyperTerminal) to the switch console port.
When using the management method, configure the terminal-emulation program to use the following parameters (you can change these settings after login):
[Default parameters]
115,200bps
8 data bits
No parity
1 stop bit
User’s Manual 94
Hardened Managed PoE Ethernet Switch
Exec Mode (View Mode)
Logon to Exec Mode (View Mode)
At the switch_a login: prompt just type in “root” and press <Enter> to logon to Exec Mode (or View Mode). switch_a login: root
User’s Manual 95
Hardened Managed PoE Ethernet Switch
Basic commands
Exec Mode (or View Mode) is the base mode from where users can perform basic commands like: clear, debug, disable, enable, exit, help, logout, no, quit, show, terminal
The CLI contains a text-based help facility. Access this help by typing in the full or partial command string then typing a question mark “?”. The CLI displays the command keywords or parameters along with a short description.
At the switch_a> prompt just press <?> to list the above basic commands. switch_a>?
At the switch_a> prompt just type in the full or partial command string then typing a question mark “?” to display the command keywords or parameters along with a short description. switch_a>show ?
User’s Manual 96
Hardened Managed PoE Ethernet Switch
Login timed out
The login session to Exec Mode (or View Mode) has timed out due to an extended period of inactivity (60 seconds) to indicate authentication attempt timed out. And the switch_a login: prompt will show on the screen.
Logon back to Exec Mode (View Mode)
User’s Manual 97
Hardened Managed PoE Ethernet Switch
At the switch_a login: prompt just type in “root” and press <Enter> to logon back to Exec Mode (or View Mode). switch_a login: root
Exit from Exec Mode (View Mode)
At the switch_a> prompt just type in “exit” and press <Enter> to exit from
Exec Mode (or View Mode). switch_a>exit
User’s Manual 98
Hardened Managed PoE Ethernet Switch
Privileged Exec Mode (Enable Mode)
Logon to Privileged Exec Mode (Enable Mode)
At the switch_a> prompt just type in “enable” and press <Enter> to logon to
Privileged Exec Mode (or Enable Mode). And the switch_a# prompt will show on the screen. switch_a>enable
User’s Manual 99
Hardened Managed PoE Ethernet Switch
Commands
Privileged Exec Mode (or Enable Mode) allows users to run commands as following.
At the switch_a# prompt just press <?> to list the commands. switch_a#?
User’s Manual 100
Hardened Managed PoE Ethernet Switch
At the switch_a# prompt just type in the full or partial command string then typing a question mark “?” to display the command keywords or parameters along with a short description. switch_a#show ?
User’s Manual 101
Hardened Managed PoE Ethernet Switch
Login timed out
The login session to Privileged Exec Mode (or Enable Mode) has timed out due to an extended period of inactivity (60 seconds) to indicate authentication attempt timed out. And the switch_a login: prompt will show on the screen.
Logon back to Exec Mode (View Mode)
At the switch_a login: prompt just type in “root” and press <Enter> to logon back to Exec Mode (or View Mode). switch_a login: root
User’s Manual 102
Hardened Managed PoE Ethernet Switch
Exit from Privileged Exec Mode (or Enable Mode)
At the switch_a# prompt just type in “exit” and press <Enter> to exit from
Privileged Exec Mode (or Enable Mode). switch_a#exit
User’s Manual 103
Hardened Managed PoE Ethernet Switch
Configure Mode (Configure Terminal Mode)
Logon to Configure Mode (Configure Terminal Mode)
At the switch_a# prompt just type in “configure terminal” and press <Enter> to logon to Configure Mode (or Configure Terminal Mode). And the
switch_a(config)# prompt will show on the screen. switch_a#configure terminal
Commands
Configure Mode (or Configure Terminal Mode) serves as a gateway into the modes as following.
At the switch_a(config)# prompt just press <?> to list the commands. switch_a(config)#?
User’s Manual 104
Hardened Managed PoE Ethernet Switch
At the switch_a(config)# prompt just type in the full or partial command string then typing a question mark “?” to display the command keywords or parameters along with a short description. switch_a(config)#show ?
User’s Manual 105
Hardened Managed PoE Ethernet Switch
Login timed out
The login session to Configure Mode (or Configure Terminal Mode) has timed out due to an extended period of inactivity (60 seconds) to indicate authentication attempt timed out. And the switch_a login: prompt will show on the screen.
Logon back to Exec Mode (View Mode)
At the switch_a login: prompt just type in “root” and press <Enter> to logon back to Exec Mode (or View Mode). switch_a login: root
User’s Manual 106
Hardened Managed PoE Ethernet Switch
Exit from Configure Mode (or Configure Terminal Mode)
At the switch_a(config)# prompt just type in “exit” and press <Enter> to exit from Configure Mode (or Configure Terminal Mode). switch_a(config)#exit
User’s Manual 107
Hardened Managed PoE Ethernet Switch
System
System Information, System Name/Password, IP Address, ARP Table, Route
Table, Save Configuration, Firmware Upgrade, Reboot, Logout
System Name/Password
System Name:
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen. switch_a(config)#
2. Usage:
Use hostname command to set or change the network server name.
Use the no hostname command to disable this function.
3. Command Syntax:
(no) hostname HOSTNAME
HOSTNAME specifies the network name of the system.
4. Example:
The following example sets the hostname to switch, and shows the change in the prompt: switch_a(config)#hostname switch switch(config)#
Password:
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen. switch_a(config)#
2. Usage:
Use enable password command to modify or create a password to be used when entering the Enable mode.
3. Command Syntax: enable password PASSWORD
PASSWORD specifies the new password of the system.
4. Example:
The following example sets the new password mypasswd to switch: switch_a(config)#enable password mypasswd
User’s Manual 108
Hardened Managed PoE Ethernet Switch
switch_a(config)#
IP Address
IP Address/IP Subnet Mask:
1. Command Mode: Interface mode
Logon to Configure Mode (Configure Terminal Mode).
Then logon to Interface mode. vlan1.1 means vlan 1.
The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface vlan1.1 switch_a(config-if)#
2. Usage:
Use ip address command to set the IP address of an interface.
Use the no ip address command to remove the IP address from an interface.
3. Command Syntax: ip address IP-ADDRESS no ip address IP-ADDRESS no ip address
IP-ADDRESS A.B.C.D/M specifies the IP address and prefix length of an interface.
M specifies IP subnet mask, 8: 255.0.0.0, 16:255.255.0.0, 24:
255.255.255.0.
4. Example:
The following example sets the new IP address 192.168.1.10 and new IP subnet mask 255.255.255.0 to switch: switch_a(config)#interface vlan1.1 switch_a(config-if)#ip address 192.168.1.10/24 switch_a(config-if)#
Default Gateway:
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen. switch_a(config)#
2. Usage:
Use ip default-gateway command to set the IP address of the default gateway.
Use the no ip default-gateway command to remove the IP address of the default gateway.
User’s Manual 109
Hardened Managed PoE Ethernet Switch
3. Command Syntax: ip default-gateway IP-ADDRESS no ip default-gateway
IP-ADDRESS A.B.C.D specifies the IP address of the default gateway.
4. Example:
The following example sets the default gateway 192.168.1.254 to switch: switch_a(config)#ip default-gateway 192.168.1.254 switch_a(config)#
DNS Server:
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen. switch_a(config)#
2. Usage:
Use ip dns command to set the IP address of the DNS server.
Use the no ip dns command to remove the IP address of the DNS server.
3. Command Syntax: ip dns IP-ADDRESS no ip dns
IP-ADDRESS A.B.C.D specifies the IP address of the DNS server.
4. Example:
The following example sets the DNS server 192.168.1.100 to switch: switch_a(config)#ip dns 192.168.1.100 switch_a(config)#
ARP Table
1. Command Mode: Privileged Exec mode
Logon to Privileged Exec Mode (Enable Mode).
The switch_a# prompt will show on the screen. switch_a(config)#
2. Usage:
Use show arp-table command to view ARP Table.
3. Command Syntax: show arp-table
4. Example:
User’s Manual 110
Hardened Managed PoE Ethernet Switch
The following example shows the ARP Table of switch: switch_a#show arp-table
Route Table
1. Command Mode: Privileged Exec mode
Logon to Privileged Exec Mode (Enable Mode).
The switch_a# prompt will show on the screen. switch_a(config)#
2. Usage:
Use show route-table command to view Route Table.
3. Command Syntax: show route-table
4. Example:
The following example shows the Route Table of switch: switch_a#show route-table
Save Configuration
Load config from TFTP server:
1. Command Mode: Privileged Exec mode
Logon to Privileged Exec Mode (Enable Mode).
The switch_a# prompt will show on the screen. switch_a#
2. Usage:
Use install image command to load configuration file from tftp server to switch.
3. Command Syntax: install image IP-ADDRESS WORD
IP-ADDRESS specifies the IP address of tftp server.
WORD specifies the file name to be loaded to switch.
4. Example:
The following example specifies upgrading firmware (file name: flash.tgz) from tftp server (IP address: 192.168.1.100) to switch: switch_a#install image 192.168.1.100 flash.tgz switch_a#
Load config to TFTP server:
User’s Manual 111
Hardened Managed PoE Ethernet Switch
1. Command Mode: Privileged Exec mode
Logon to Privileged Exec Mode (Enable Mode).
The switch_a# prompt will show on the screen. switch_a#
2. Usage:
Use write config-file command to backup configuration file to tftp server.
3. Command Syntax: write config-file IP-ADDRESS
IP-ADDRESS specifies the IP address of tftp server.
4. Example:
The following example backups configuration file to tftp server (IP address:
192.168.1.20): switch_a#write config-file 192.168.1.20 switch_a#
Save Configuration:
1. Command Mode: Privileged Exec mode
Logon to Privileged Exec Mode (Enable Mode).
The switch_a# prompt will show on the screen. switch_a#
2. Usage:
Use copy running-config startup-config command to write configurations to the file to be used at startup. This is the same as the write memory command.
3. Command Syntax: copy running-config startup-config
4. Example:
The following example specifies writing configurations to the file to be used at startup to switch: switch_a#copy running-config startup-config switch_a#
Restore Default:
1. Command Mode: Privileged Exec mode
Logon to Privileged Exec Mode (Enable Mode).
The switch_a# prompt will show on the screen. switch_a#
User’s Manual 112
Hardened Managed PoE Ethernet Switch
2. Usage:
Use restore default command to restore default setting of the switch.
3. Command Syntax: restore default
4. Example:
The following example restores default setting of the switch: switch_a#restore default switch_a#
Auto Save:
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen. switch_a(config)#
2. Usage:
Use this command to enable auto save configuration function. The configuration will be automatically saved at every configured interval while this command is enabled. Use the no form of this command to disable this feature.
3. Command Syntax: service auto-config enable no service auto-config enable
4. Example:
The following example enables or disables auto save configuration to switch: switch_a(config)#service auto-config enable switch_a(config)#no service auto-config enable switch_a(config)#
Auto Save Interval (5~65536 sec):
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen. switch_a(config)#
2. Usage:
Use this command to set the interval when the configuration would be automatically saved. The range of interval value is from 5 to 65535. And the default value is 30 seconds.
User’s Manual 113
Hardened Managed PoE Ethernet Switch
3. Command Syntax: service auto-config interval WORD
WORD specifies the interval value.
4. Example:
The following example sets the interval WORD (10) when the configuration would be automatically saved to switch: switch_a(config)#service auto-config interval 10 switch_a(config)#
Firmware Upgrade
1. Command Mode: Privileged Exec mode
Logon to Privileged Exec Mode (Enable Mode).
The switch_a# prompt will show on the screen. switch_a#
2. Usage:
Use install image command to upgrade firmware from tftp server to switch.
3. Command Syntax: install image IP-ADDRESS WORD
IP-ADDRESS specifies the IP address of tftp server.
WORD specifies the file name to be upgraded to switch.
4. Example:
The following example specifies upgrading firmware (file name: flash.tgz) from tftp server (IP address: 192.168.1.100) to switch: switch_a#install image 192.168.1.100 flash.tgz switch_a#
Please follow the message on the screen during the firmware upgrade process. Do not turn off the power or perform other functions during this period of time.
User’s Manual 114
Hardened Managed PoE Ethernet Switch
At the “switch_a#” prompt just type in “reload” and press <Enter> to reboot the switch after completing the upgrade process.
User’s Manual 115
Hardened Managed PoE Ethernet Switch
Reboot
1. Command Mode: Privileged Exec mode
Logon to Privileged Exec Mode (Enable Mode).
The switch_a# prompt will show on the screen. switch_a#
2. Usage:
Use reload command to restart switch.
3. Command Syntax: reload
4. Example:
The following example specifies restarting switch: switch_a#reload switch_a login:
Logout
1. Command Mode: Exec mode or Privileged Exec mode
Logon to Exec Mode (View Mode) or Privileged Exec Mode (Enable Mode).
The switch_a> or switch_a# prompt will show on the screen. switch_a> switch_a#
2. Usage:
Use logout command to exit from the Exec mode or Privileged Exec mode.
3. Command Syntax: logout
4. Example:
The following example specifies to exit from the Exec mode or Privileged
Exec mode. switch_a>logout switch_a login:
User’s Manual 116
Hardened Managed PoE Ethernet Switch
Port
Configuration, Port Status, Rate Control, RMON Statistics, Per Port Vlan
Activities
Configuration
Admin Setting:
1. Command Mode: Interface mode
Logon to Configure Mode (Configure Terminal Mode).
Then logon to Interface mode. fe1 means port 1.
The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface fe1 switch_a(config-if)#
2. Usage:
Use the shutdown command to shut down the selected interface.
Use the no shutdown to disable this function.
3. Command Syntax:
(no) shutdown
4. Example:
The following example shows the use of the shutdown command to shut down the interface fe1 (port 1): switch_a(config)#interface fe1 switch_a(config-if)#shutdown switch_a(config-if)#
Bandwidth:
1. Command Mode: Interface mode
Logon to Configure Mode (Configure Terminal Mode).
Then logon to Interface mode. fe1 means port 1.
The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface fe1 switch_a(config-if)#
2. Usage:
Use this command to specify the bandwidth for each interface. The bandwidth value is in bits.
Use the no parameter with this command to remove the bandwidth for each interface.
User’s Manual 117
Hardened Managed PoE Ethernet Switch
3. Command Syntax:
Bandwidth BANDWIDTH no bandwidth
BANDWIDTH
<1-10000000000 bits> (usable units: k, m, g)
<1-999>k|m for 1 to 999 kilo bits or mega bits.
1g for 1 giga bits.
4. Example:
The following example shows the use of bandwidth BANDWIDTH (10 mega
bits) to the interface fe1 (port 1): switch_a(config)#interface fe1 switch_a(config-if)#bandwidth 10m switch_a(config-if)#
Duplex:
1. Command Mode: Interface mode
Logon to Configure Mode (Configure Terminal Mode).
Then logon to Interface mode. fe1 means port 1.
The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface fe1 switch_a(config-if)#
2. Usage:
Use duplex command to specify the duplex mode to be used for each interface.
Use the no duplex to disable this function.
3. Command Syntax:
(no) duplex MODE
MODE specifies the duplex mode: auto, full, half.
4. Example:
The following example shows the use of duplex MODE (full) to the interface fe1 (port 1): switch_a(config)#interface fe1 switch_a(config-if)#duplex full switch_a(config-if)#
Flow control:
1. Command Mode: Interface mode
Logon to Configure Mode (Configure Terminal Mode).
User’s Manual 118
Hardened Managed PoE Ethernet Switch
Then logon to Interface mode. fe1 means port 1.
The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface fe1 switch_a(config-if)#
2. Usage:
Use flowcontrol on command to enable flow control, and configure the flow control mode for the port.
Use the no flowcontrol to disable this function.
3. Command Syntax: flowcontrol on no flowcontrol
4. Example:
The following example shows the use of flowcontrol on to the interface fe1
(port 1): switch_a(config)#interface fe1 switch_a(config-if)#flowcontrol on switch_a(config-if)#
Port Status
1. Command Mode: Exec mode or Privileged Exec mode
Logon to Exec Mode (View Mode) or Privileged Exec Mode (Enable Mode).
The switch_a> or switch_a# prompt will show on the screen. switch_a> switch_a#
2. Usage:
Use the show interface command to display interface configuration and status.
3. Command Syntax: show interface IFNAME
IFNAME specifies the name of the interface for which status and configuration information is desired.
4. Example:
The following example shows the use of show interface to display interface configuration and status of the interface fe1 (port 1): switch_a>show interface fe1
User’s Manual 119
Hardened Managed PoE Ethernet Switch
Rate Control
1. Command Mode: Interface mode
Logon to Configure Mode (Configure Terminal Mode).
Then logon to Interface mode. fe1 means port 1.
The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface fe1 switch_a(config-if)#
2. Usage:
Use this command to specify the ingress/egress rate to be used for each interface. The bandwidth value is in bits.
Use the no parameter with this command to remove the ingress/egress rate to be used for each interface.
3. Command Syntax:
(no) rate-control ingress/egress VALUE
VALUE
<1-10000000000 bits> (usable units: k, m, g)
<1-999>k|m for 1 to 999 kilo bits or mega bits.
1g for 1 giga bits.
4. Example:
The following example shows the use of rate-control ingress VALUE (10
mega bits) to the interface fe1 (port 1): switch_a(config)#interface fe1 switch_a(config-if)#rate-control ingress 10m switch_a(config-if)#
RMON Statistics
1. Command Mode: Exec mode or Privileged Exec mode
Logon to Exec Mode (View Mode) or Privileged Exec Mode (Enable Mode).
The switch_a> or switch_a# prompt will show on the screen. switch_a> switch_a#
2. Usage:
Use the show interface statistics command to display RMON statistics of interface.
3. Command Syntax: show interface statistics IFNAME
IFNAME specifies the name of the interface for which RMON statistics is desired.
User’s Manual 120
Hardened Managed PoE Ethernet Switch
4. Example:
The following example shows the use of show interface statistics to display
RMON statistics of the interface fe1 (port 1): switch_a>show interface statistics fe1
Per Port Vlan Activities
1. Command Mode: Exec mode or Privileged Exec mode
Logon to Exec Mode (View Mode) or Privileged Exec Mode (Enable Mode).
The switch_a> or switch_a# prompt will show on the screen. switch_a> switch_a#
2. Usage:
Use show vlan command to display information about a particular VLAN by specifying the VLAN ID.
3. Command Syntax: show vlan <2-4094>
<2-4094> VLAN ID.
4. Example:
The following is an output of show vlan command displaying information about VLAN 2: switch_a>show vlan 2
User’s Manual 121
Hardened Managed PoE Ethernet Switch
Switching
Bridging, Static MAC Entry, Port Mirroring, PoE, PoE Scheduling
Bridging
Aging Time (seconds):
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen. switch_a(config)#
2. Usage:
Use this command to specify an ageing-out time for a learned MAC address.
The learned MAC address will persist till this specified time.
3. Command Syntax:
Bridge GROUP ageing-time AGEINGTIME no bridge GROUP ageing-time
Group = <1-1> The ID of the bridge-group that this ageing time is for.
AGEINGTIME = <10-1000000> The number of seconds of persistence.
4. Example:
The following example sets the new AGEINGTIME (1000) to bridge GROUP
(1): switch_a(config)#bridge 1 ageing-time 1000 switch_a(config)#
Threshold level (0-100):
1. Command Mode: Interface mode
Logon to Configure Mode (Configure Terminal Mode).
Then logon to Interface mode. fe1 means port 1.
The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface fe1 switch_a(config-if)#
2. Usage:
Use storm-control level command to specify the rising threshold level for broadcasting, multicast, or destination lookup failure traffic. The storm control action occurs when traffic utilization reaches this level.
3. Command Syntax: storm-control level LEVEL
User’s Manual 122
Hardened Managed PoE Ethernet Switch
LEVEL <0-100> specifies the percentage of the threshold; percentage of the maximum speed (pps) of the interface.
4. Example:
The following example shows setting storm-control level LEVEL (30) to the interface fe1 (port 1): switch_a(config)#interface fe1 switch_a(config-if)#storm-control level 30 switch_a(config-if)#
Broadcast:
1. Command Mode: Interface mode
Logon to Configure Mode (Configure Terminal Mode).
Then logon to Interface mode. fe1 means port 1.
The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface fe1 switch_a(config-if)#
2. Usage:
Use storm-control broadcast enable command to enable broadcast traffic.
Use no storm-control broadcast command to disable broadcast traffic.
3. Command Syntax: storm-control broadcast enable no storm-control broadcast
4. Example:
The following example shows setting storm-control broadcast enable to the interface fe1 (port 1): switch_a(config)#interface fe1 switch_a(config-if)#storm-control broadcast enable switch_a(config-if)#
Multicast:
1. Command Mode: Interface mode
Logon to Configure Mode (Configure Terminal Mode).
Then logon to Interface mode. fe1 means port 1.
The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface fe1 switch_a(config-if)#
2. Usage:
User’s Manual 123
Hardened Managed PoE Ethernet Switch
Use storm-control multicast enable command to enable multicast traffic.
Use no storm-control multicast command to disable multicast traffic.
3. Command Syntax: storm-control multicast enable no storm-control multicast
4. Example:
The following example shows setting storm-control multicast enable to the interface fe1 (port 1): switch_a(config)#interface fe1 switch_a(config-if)#storm-control multicast enable switch_a(config-if)#
DLF:
1. Command Mode: Interface mode
Logon to Configure Mode (Configure Terminal Mode).
Then logon to Interface mode. fe1 means port 1.
The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface fe1 switch_a(config-if)#
2. Usage:
Use storm-control dlf enable command to enable destination lookup failure traffic.
Use no storm-control dlf command to disable destination lookup failure traffic.
3. Command Syntax: storm-control dlf enable no storm-control dlf
dlf destination lookup failure
4. Example:
The following example shows setting storm-control dlf enable to the interface fe1 (port 1): switch_a(config)#interface fe1 switch_a(config-if)#storm-control dlf enable switch_a(config-if)#
Static MAC Entry
Static-MAC-Entry Forward:
1. Command Mode: Configure mode
User’s Manual 124
Hardened Managed PoE Ethernet Switch
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen. switch_a(config)#
2. Usage:
Use this command to statically configure a bridge entry to forward matching frames.
3. Command Syntax: bridge GROUP address MAC forward IFNAME VLANID no bridge GROUP address MAC forward IFNAME VLANID
GROUP <1-1> Bridge-group ID used for bridging.
MAC the Media Access Control (MAC) address in the HHHH.HHHH.HHHH format.
IFNAME the interface on which the frame comes in.
VLANID The VID of the VLAN that will be enabled or disabled on the bridge
<2-4094>.
4. Example:
The following example configures a bridge GROUP (1) to forward matching frames (MAC address 2222.2222.2222) to the interface fe1 (port 1) in vlan
VLANID (2): switch_a(config)#bridge 1 address 2222.2222.2222 forward fe1 vlan 2 switch_a(config)#
Static-MAC-Entry Discard:
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen. switch_a(config)#
2. Usage:
Use this command to statically configure a bridge entry to discard matching frames in a particular VLAN.
3. Command Syntax: bridge GROUP address MAC discard vlan VLANID no bridge GROUP address MAC discard vlan VLANID
GROUP <1-1> Bridge-group ID used for bridging.
MAC the Media Access Control (MAC) address in the HHHH.HHHH.HHHH format.
VLANID The VID of the VLAN on the bridge <1-4094>.
4. Example:
The following example configures a bridge GROUP (1) to discard matching frames (MAC address 2222.2222.2222) in vlan VLANID (1):
User’s Manual 125
Hardened Managed PoE Ethernet Switch
switch_a(config)#bridge 1 address 2222.2222.2222 discard vlan 1 switch_a(config)#
Port Mirroring
1. Command Mode: Interface mode
Logon to Configure Mode (Configure Terminal Mode).
Then logon to Interface mode. fe1 means port 1.
The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface fe1 switch_a(config-if)#
2. Usage:
Use this command to define a mirror source port and its direction.
Use the no parameter with this command to disable port mirroring by the destination port on the specified source port.
3. Command Syntax: mirror interface SOURCEPORT direction SNOOPDIRECTION no mirror interface SOURCEPORT
SOURCEPORT Name of the Source interface to be used.
SNOOPDIRECTION [both|receive|transmit] both Specifies mirroring of traffic in both directions. receive Specifies mirroring of received traffic. transmit Specifies mirroring of transmitted traffic.
4. Example:
The following example enables port mirroring by the destination port fe1 (port
1) on the specified source port fe2 (port 2): switch_a(config)#interface fe1 switch_a(config-if)#mirror interface fe2 direction both switch_a(config-if)#
PoE
System Power Budget:
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen. switch_a(config)#
2. Usage:
Use this command to specify the power budget (Watts) to be set to Switch.
3. Command Syntax:
User’s Manual 126
Hardened Managed PoE Ethernet Switch
poe system-power-budget LEVEL
LEVEL <1-800> specifies the power budget (Watts) to be set to Switch.
4. Example:
The following example sets new power budget 246 Watts to Switch: switch_a(config)#poe system-power-budget 246 switch_a(config)#
Enable Mode:
1. Command Mode: Interface mode
Logon to Configure Mode (Configure Terminal Mode).
Then logon to Interface mode. fe1 means port 1.
The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface fe1 switch_a(config-if)#
2. Usage:
Use poe enable command to enable this port to discover Powered Device
(PD) connected to this port.
Use the no poe enable to disable this function.
3. Command Syntax:
(no) poe enable
4. Example:
The following example shows the use of poe enable to the interface fe1 (port
1): switch_a(config)#interface fe1 switch_a(config-if)#poe enable switch_a(config-if)#
Power Limit by Classification:
1. Command Mode: Interface mode
Logon to Configure Mode (Configure Terminal Mode).
Then logon to Interface mode. fe1 means port 1.
The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface fe1 switch_a(config-if)#
2. Usage:
Use poe power-classification enable command to enable this port to provide power to PD according to classification of maximum power range
User’s Manual 127
Hardened Managed PoE Ethernet Switch
used by PD.
Use the no poe power-classification enable to disable this function.
3. Command Syntax:
(no) poe power-classification enable
4. Example:
The following example shows the use of poe power-classification enable to the interface fe1 (port 1): switch_a(config)#interface fe1 switch_a(config-if)#poe power-classification enable switch_a(config-if)#
Fixed Power Limit (W):
1. Command Mode: Interface mode
Logon to Configure Mode (Configure Terminal Mode).
Then logon to Interface mode. fe1 means port 1.
The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface fe1 switch_a(config-if)#
2. Usage:
Use this command to specify the fixed power limit for this port to provide power to PD.
3. Command Syntax: poe fixed-power-limit LEVEL
LEVEL <1-15.4> specifies the fixed power limit (Watts) for this port to provide power to PD.
4. Example:
The following example sets new fixed power limit 15 Watts to the interface fe1 (port 1): switch_a(config)#interface fe1 switch_a(config-if)#poe fixed-power-limit 15 switch_a(config-if)#
Power Priority:
1. Command Mode: Interface mode
Logon to Configure Mode (Configure Terminal Mode).
Then logon to Interface mode. fe1 means port 1.
The switch_a(config-if)# prompt will show on the screen.
User’s Manual 128
Hardened Managed PoE Ethernet Switch
switch_a(config)#interface fe1 switch_a(config-if)#
2. Usage:
Use this command to specify the power priority to this port.
3. Command Syntax: poe power-priority PRIORITY
PRIORITY specifies high, medium, low power priority for this port.
4. Example:
The following example sets high power priority to the interface fe1 (port 1): switch_a(config)#interface fe1 switch_a(config-if)#poe power-priority high switch_a(config-if)#
PoE Scheduling
PoE Schedule:
1. Command Mode: Interface mode
Logon to Configure Mode (Configure Terminal Mode).
Then logon to Interface mode. fe1 means port 1.
The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface fe1 switch_a(config-if)#
2. Usage:
Use this command to enble PoE scheduling to this port.
3. Command Syntax: poe schedule enable
4. Example:
The following example enables PoE scheduling to the interface fe1 (port 1): switch_a(config)#interface fe1 switch_a(config-if)#poe schedule enable switch_a(config-if)#
PoE Schedule:
1. Command Mode: Interface mode
Logon to Configure Mode (Configure Terminal Mode).
Then logon to Interface mode. fe1 means port 1.
The switch_a(config-if)# prompt will show on the screen.
User’s Manual 129
Hardened Managed PoE Ethernet Switch
switch_a(config)#interface fe1 switch_a(config-if)#
2. Usage:
Use this command to set PoE scheduling to this port.
3. Command Syntax: poe schedule-time DAY HOUR
DAY <0-6> specifies Sunday ~ Saturday to Switch.
HOUR <0-23> specifies hours to Switch. no poe schedule-time
4. Example:
The following example sets PoE scheduling to the interface fe1 (port 1): switch_a(config)#interface fe1 switch_a(config-if)#poe schedule-time 0 0 switch_a(config-if)#
User’s Manual 130
Hardened Managed PoE Ethernet Switch
Trunking
Port Trunking
Port Trunking
1. Command Mode: Interface mode
Logon to Configure Mode (Configure Terminal Mode).
Then logon to Interface mode. fe1 means port 1.
The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface fe1 switch_a(config-if)#
2. Usage:
Use static-channel-group command to create a static aggregator, or add a member port to an already-existing static aggregator.
Use the no static-channel-group command to detach the port from the static aggregator.
3. Command Syntax: static-channel-group <1-8> no static-channel-group
<1-8> Channel group number.
Maximum 8 ports in static-channel-group 1 to 6.
Maximum 4 ports in static-channel-group 7 and 8.
4. Example:
The following example adding the interface fe1 (port 1) to
static-channel-group 1: switch_a(config)#interface fe1 switch_a(config-if)#static-channel-group 1 switch_a(config-if)#
User’s Manual 131
Hardened Managed PoE Ethernet Switch
STP / Ring
Global Configuration, RSTP Port Setting, MSTP Properties, MSTP Instance
Setting, MSTP Port Setting, Recover-Ring(tm) Capability
Global Configuration
STP Version:
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen. switch_a(config)#
2. Usage:
Use this command to choose the Spanning Tree protocol, Rapid Spanning
Tree protocol, or Multiple Spanning Tree protocol on a bridge.
3. Command Syntax: bridge GROUP protocol PROTOCOL vlan-bridge
GROUP <1-1> Bridge group name used for bridging.
PROTOCOL
ieee IEEE 802.1Q spanning-tree protocol.
mstp IEEE 802.1s multiple spanning-tree protocol. rstp IEEE 802.1w rapid spanning-tree protocol.
4. Example:
The following example chooses the PROTOCOL (rstp) on bridge GROUP
(1): switch_a(config)#bridge 1 protocol rstp vlan-bridge switch_a(config)#
Multiple Spanning Tree Protocol:
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen. switch_a(config)#
2. Usage:
Use this command to enable the Multiple Spanning Tree protocol on a bridge.
Use the no form of the command to disable the Multiple Spanning Tree protocol on a bridge.
3. Command Syntax: bridge GROUP multiple-spanning-tree enable
User’s Manual 132
Hardened Managed PoE Ethernet Switch
no bridge GROUP multiple-spanning-tree enable BRIDGE-FORWARD
GROUP <1-1> Bridge group name used for bridging.
BRIDGE-FORWARD Puts all ports of the specified bridge into the forwarding state.
4. Example:
The following example enables or disables the multiple-spanning-tree on bridge GROUP (1): switch_a(config)#bridge 1 multiple-spanning-tree enable switch_a(config)#no bridge 1 multiple-spanning-tree enable bridge-forward switch_a(config)#
Rapid Spanning Tree Protocol:
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen. switch_a(config)#
2. Usage:
Use this command to enable the Rapid Spanning Tree protocol on a bridge.
Use the no form of the command to disable the Rapid Spanning Tree protocol on a bridge.
3. Command Syntax: bridge GROUP rapid-spanning-tree enable no bridge GROUP rapid-spanning-tree enable BRIDGE-FORWARD
GROUP <1-1> Bridge group name used for bridging.
BRIDGE-FORWARD Puts all ports of the specified bridge into the forwarding state.
4. Example:
The following example enables or disables the rapid-spanning-tree on bridge GROUP (1): switch_a(config)#bridge 1 rapid-spanning-tree enable switch_a(config)#no bridge 1 rapid-spanning-tree enable bridge-forward switch_a(config)#
Spanning Tree Protocol:
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen. switch_a(config)#
2. Usage:
User’s Manual 133
Hardened Managed PoE Ethernet Switch
Use this command to enable the Spanning Tree protocol on a bridge.
Use the no form of the command to disable the Spanning Tree protocol on a bridge.
3. Command Syntax: bridge GROUP spanning-tree enable no bridge GROUP spanning-tree enable BRIDGE-FORWARD
GROUP <1-1> Bridge group name used for bridging.
BRIDGE-FORWARD Puts all ports of the specified bridge into the forwarding state.
4. Example:
The following example enables or disables the spanning-tree on bridge
GROUP (1): switch_a(config)#bridge 1 spanning-tree enable switch_a(config)#no bridge 1 spanning-tree enable bridge-forward switch_a(config)#
Bridge Priority (0..61440):
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen. switch_a(config)#
2. Usage:
Use this command to set bridge priority for the common instance. Using a lower priority indicates a greater likelihood of the bridge becoming root.
3. Command Syntax: bridge GROUP priority PRIORITY no bridge GROUP priority
GROUP <1-1> The ID of the bridge group for which the priority is set.
PRIORITY <0-61440> The bridge priority.
4. Example:
The following example sets the priority PRIORITY (4096) of bridge GROUP
(1): switch_a(config)#bridge 1 priority 4096 switch_a(config)#
Hello Time (sec) (1..9):
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen.
User’s Manual 134
Hardened Managed PoE Ethernet Switch
switch_a(config)#
2. Usage:
Use this command to set the hello-time, the time in seconds after which (if this bridge is the root bridge) all the bridges in a bridged LAN exchange
Bridge Protocol Data Units (BPDUs).
3. Command Syntax: bridge GROUP hello-time HELLOTIME no bridge GROUP hello-time
GROUP <1-1> The ID of the bridge group to which this hello time is assigned.
HELLOTIME <1-9> The hello BPDU interval in seconds.
4. Example:
The following example sets the hello-time HELLOTIME (9) of bridge GROUP
(1): switch_a(config)#bridge 1 hello-time 9 switch_a(config)#
Max Age (sec) (6..28):
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen. switch_a(config)#
2. Usage:
Use this command to set the max-age for a bridge.
Use the no parameter with this command to restore the default value of max-age.
3. Command Syntax: bridge GROUP max-age MAXAGE no bridge GROUP max-age
GROUP <1-1> The ID of the bridge group to which this maximum age time is assigned.
MAXAGE <6-28> The maximum time, in seconds, to listen for the root bridge.
4. Example:
The following example sets the max-age MAXAGE (28) of bridge GROUP
(1): switch_a(config)#bridge 1 max-age 28 switch_a(config)#
User’s Manual 135
Hardened Managed PoE Ethernet Switch
Forward Delay (sec) (4..30):
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen. switch_a(config)#
2. Usage:
Use this command to set the time (in seconds) after which (if this bridge is the root bridge) each port changes states to learning and forwarding.
Use the no parameter with this command to restore the default value.
3. Command Syntax: bridge GROUP forward-time FORWARD_DELAY no bridge GROUP forward-time
GROUP <1-1> The ID of the bridge group to which this delay time is assigned.
FORWARD_DELAY <4-30> the forwarding time delay in seconds.
4. Example:
The following example sets the forward-time FORWARD_DELAY (30) of bridge GROUP (1): switch_a(config)#bridge 1 forward-time 30 switch_a(config)#
RSTP Port Setting
Priority(Granularity 16):
1. Command Mode: Interface mode
Logon to Configure Mode (Configure Terminal Mode).
Then logon to Interface mode. fe1 means port 1.
The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface fe1 switch_a(config-if)#
2. Usage:
Use this command to set the port priority for a bridge. The lower priority indicates a greater likelihood of the bridge becoming root.
3. Command Syntax: bridge GROUP priority PRIORITY
GROUP <1-1> the ID of the bridge group.
PRIORITY <0-240> The priority to be assigned to the group.
4. Example:
The following example sets the priority PRIORITY (100) of the interface fe1
User’s Manual 136
Hardened Managed PoE Ethernet Switch
(port 1) of bridge GROUP (1): switch_a(config)#interface fe1 switch_a(config-if)#bridge 1 priority 100 switch_a(config-if)#
Admin. Path Cost:
1. Command Mode: Interface mode
Logon to Configure Mode (Configure Terminal Mode).
Then logon to Interface mode. fe1 means port 1.
The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface fe1 switch_a(config-if)#
2. Usage:
Use this command to set the cost of a path associated with a bridge-group.
Use the no parameter with this command to restore the default cost of a path associated with a bridge-group.
3. Command Syntax: bridge GROUP path-cost PATHCOST no bridge GROUP path-cost
GROUP <1-1> the ID of the bridge group.
PATHCOST <1-200000000> The cost to be assigned to the group.
4. Example:
The following example sets the cost (123) of the interface fe1 (port 1) of bridge GROUP (1): switch_a(config)#interface fe1 switch_a(config-if)#bridge 1 path-cost 123 switch_a(config-if)#
Point to Point Link:
1. Command Mode: Interface mode
Logon to Configure Mode (Configure Terminal Mode).
Then logon to Interface mode. fe1 means port 1.
The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface fe1 switch_a(config-if)#
2. Usage:
Use spanning-tree link-type command to set the link type of a port to enable or disable rapid transition.
User’s Manual 137
Hardened Managed PoE Ethernet Switch
Use the no spanning-tree link-type command to set a port to its default state and to disable rapid transition.
3. Command Syntax:
(no) spanning-tree link-type LINKTYPE
LINKTYPE The link type to be assigned to the port.
point-to-point Enable rapid transition.
shared Disable rapid transition.
4. Example:
The following example sets the link-type LINKTYPE (point-to-point) of the interface fe1 (port 1): switch_a(config)#interface fe1 switch_a(config-if)#spanning-tree link-type point-to-point switch_a(config-if)#
Autoedge:
1. Command Mode: Interface mode
Logon to Configure Mode (Configure Terminal Mode).
Then logon to Interface mode. fe1 means port 1.
The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface fe1 switch_a(config-if)#
2. Usage:
Use spanning-tree autoedge command to assist in automatic identification of the edge port.
Use the no spanning-tree autoedge command to disable this feature.
3. Command Syntax:
(no) spanning-tree autoedge
4. Example:
The following example enables the spanning-tree autoedge of the interface fe1 (port 1): switch_a(config)#interface fe1 switch_a(config-if)#spanning-tree autoedge switch_a(config-if)#
Edgeport:
1. Command Mode: Interface mode
Logon to Configure Mode (Configure Terminal Mode).
Then logon to Interface mode.
User’s Manual 138
Hardened Managed PoE Ethernet Switch
fe1 means port 1.
The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface fe1 switch_a(config-if)#
2. Usage:
Use spanning-tree edgeport command to set a port as an edge-port and to enable rapid transitions.
Use the no spanning-tree edgeport command to set a port to its default state (not an edge-port) and to disable rapid transitions.
3. Command Syntax:
(no) spanning-tree edgeport
4. Example:
The following example enables the spanning-tree edgeport of the interface fe1 (port 1): switch_a(config)#interface fe1 switch_a(config-if)#spanning-tree edgeport switch_a(config-if)#
MSTP Properties
Region Name:
1. Command Mode: MST Configuration mode
Logon to Configure Mode (Configure Terminal Mode).
Then logon to MST Configuration mode.
The switch_a(config-mst)# prompt will show on the screen. switch_a(config)#spanning-tree mst configuration switch_a(config-mst)#
2. Usage:
Use this command to create an MST region and specify a name to it. MST bridges of a region form different spanning trees for different VLANs. By default, each MST bridge starts with the region name as its bridge address.
This means each MST bridge is a region by itself, unless specifically added to one.
3. Command Syntax: bridge GROUP region REGION_NAME no bridge GROUP region
GROUP <1-1> Specify the bridge-group ID.
REGION_NAME Specify the name of the region.
4. Example:
The following example creates an MST region and specifies a name
(regionname) to it in bridge GROUP (1):
User’s Manual 139
Hardened Managed PoE Ethernet Switch
Switch_a(config)#spanning-tree mst configuration switch_a(config-mst)#bridge 1 region regionname switch_a(config-mst)#
Revision Level:
1. Command Mode: MST Configuration mode
Logon to Configure Mode (Configure Terminal Mode).
Then logon to MST Configuration mode.
The switch_a(config-mst)# prompt will show on the screen. switch_a(config)#spanning-tree mst configuration switch_a(config-mst)#
2. Usage:
Use this command to specify the number for configuration information. The default value of revision number is 0.
3. Command Syntax: bridge GROUP revision REVISION_NUM
GROUP <1-1> Specify the bridge-group ID.
REVISION_NUM <0-255> Revision number.
4. Example:
The following example specifies a revision number (25) of MST configuration in bridge GROUP (1): switch_a(config)#spanning-tree mst configuration switch_a(config-mst)#bridge 1 revision 25 switch_a(config-mst)#
Max Hops:
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen. switch_a(config)#
2. Usage:
Use this command to specify the maximum allowed hops for BPDU in an
MST region. This parameter is used by all the instances of the MST.
Specifying the max hops for a BPDU prevents the messages from looping indefinetely in the network. When a bridge receives a MST BPDU that has exceeded the allowed max-hops, it discards the BPDU.
3. Command Syntax: bridge GROUP max-hops HOP_COUNT no bridge GROUP max-hops
User’s Manual 140
Hardened Managed PoE Ethernet Switch
GROUP <1-1> Specify the bridge-group ID.
HOP_COUNT Maximum hops the BPDU will be valid for.
4. Example:
The following example specifies the maximum allowed hops (25) for BPDU in bridge GROUP (1): switch_a(config)#bridge 1 max-hops 25 switch_a(config)#
MSTP Instance Setting
Bridge Instance VLAN:
1. Command Mode: MST Configuration mode
Logon to Configure Mode (Configure Terminal Mode).
Then logon to MST Configuration mode.
The switch_a(config-mst)# prompt will show on the screen. switch_a(config)#spanning-tree mst configuration switch_a(config-mst)#
2. Usage:
Use this command to simultaneously add multiple VLANs for the corresponding instance of a bridge. This command can be used only after the
VLANs are defined. Use the no parameter with this command to simultaneously remove multiple VLANs for the corresponding instance of a bridge.
3. Command Syntax: bridge GROUP instance INSTANCE_ID vlan VLAN_ID no bridge GROUP instance INSTANCE_ID vlan VLAN_ID
GROUP <1-1> Specify the bridge-group ID.
INSTANCE_ID <1-15> Specify the instance ID.
VLAN_ID <1-4094> Specify multiple VLAN IDs corresponding to the bridge instance
4. Example:
The following example associates multiple VLANs (10) and (20) to instance
(1) of bridge GROUP (1): switch_a(config)#bridge 1 protocol mstp switch_a(config)#spanning-tree mst configuration switch_a(config-mst)#bridge 1 instance 1 vlan 10, 20 switch_a(config-mst)#
Bridge Instance Priority:
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
User’s Manual 141
Hardened Managed PoE Ethernet Switch
The switch_a(config)# prompt will show on the screen. switch_a(config)#
2. Usage:
Use this command to set the bridge priority for an MST instance to the value specified. Use the no parameter with this command to restore the default value of the bridge priority. The lower the priority of the bridge, the better the chances are the bridge becoming a root bridge or a designated bridge for the
LAN. The priority values can be set only in increments of 4096.
3. Command Syntax: bridge GROUP instance INSTANCE_ID priority BRIDGE_PRIORITY no bridge GROUP instance INSTANCE_ID priority
GROUP <1-1> Specify the bridge-group ID.
INSTANCE_ID Specify the instance ID.
BRIDGE_PRIORITY <0-61440> Specify the bridge priority.
4. Example:
The following example sets the bridge priority (0) for an MST instance (3) in bridge GROUP (1): switch_a(config)#bridge 1 instance 3 priority 0 switch_a(config)#
MSTP Port Setting
Bridge-Group Instance:
1. Command Mode: Interface mode
Logon to Configure Mode (Configure Terminal Mode).
Then logon to Interface mode. fe1 means port 1.
The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface fe1 switch_a(config-if)#
2. Usage:
Use this command to assign a Multiple Spanning Tree instance to a port. Use the no parameter with this command to remove the instance.
3. Command Syntax: bridge GROUP instance INSTANCE_ID no bridge GROUP instance INSTANCE_ID
GROUP <1-1> Specify the bridge-group ID.
INSTANCE_ID Specify the instance ID.
4. Example:
The following example assigns a Multiple Spanning Tree instance (3) to a port
(fe1) in bridge GROUP (1):
User’s Manual 142
Hardened Managed PoE Ethernet Switch
switch_a(config)#interface fe1 switch_a(config-if)#bridge-group 1 instance 3 switch_a(config-if)#
Bridge-Group Instance Priority:
1. Command Mode: Interface mode
Logon to Configure Mode (Configure Terminal Mode).
Then logon to Interface mode. fe1 means port 1.
The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface fe1 switch_a(config-if)#
2. Usage:
Use this command to set the port priority for a bridge group. The Multiple
Spanning Tree Protocol uses port priority as a tiebreaker to determine which port should forward frames for a particular instance on a LAN, or which port should be the root port for an instance. A lower value implies a better priority.
In the case of the same priority, the interface index will serve as the tiebreaker, with the lower-numbered interface being preferred over others.
The permitted range is 0-240. The priority values can only be set in increments of 16.
3. Command Syntax: bridge GROUP instance INSTANCE_ID priority PRIORITY
GROUP <1-1> Specify the bridge-group ID.
INSTANCE_ID <1-15> Specify the instance ID.
PRIORITY <0-240> Specify the port priority in a range of <0-240>.
4. Example:
The following example sets the port priority (121) for Multiple Spanning Tree instance (3) to a port (fe1) in bridge GROUP (1): switch_a(config)#interface fe1 switch_a(config-if)#bridge-group 1 instance 3 priority 121 switch_a(config-if)#
Bridge-Group Instance Path-Cost:
1. Command Mode: Interface mode
Logon to Configure Mode (Configure Terminal Mode).
Then logon to Interface mode. fe1 means port 1.
The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface fe1 switch_a(config-if)#
User’s Manual 143
Hardened Managed PoE Ethernet Switch
2. Usage:
Use this command to set the cost of a path associated with an interface. Use the no parameter with this command to restore the default cost value of the path. A lower path-cost indicates a greater likelihood of the specific interface becoming a root.
3. Command Syntax: bridge GROUP instance INSTANCE_ID path-cost PATH_COST
GROUP <1-1> Specify the bridge-group ID.
INSTANCE_ID <1-15> Specify the instance ID.
PATH_COST <1-200000000> Specify the cost of path in the range of
<1-200000000>.
4. Example:
The following example sets the path cost (1000) for Multiple Spanning Tree instance (3) to a port (fe1) in bridge GROUP (1): switch_a(config)#interface fe1 switch_a(config-if)#bridge-group 1 instance 3 path-cost 1000 switch_a(config-if)#
Recover-Ring(tm) Capability
Ring state:
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen. switch_a(config)#
2. Usage:
Use this command to enable Ring state. Use the no parameter with this command to disable Ring state.
3. Command Syntax: bridge GROUP protocol ring no bridge GROUP ring enable BRIDGE-FORWARD
GROUP <1-1> Specify the bridge-group ID.
BRIDGE-FORWARD Puts all ports of the specified bridge into the forwarding state.
4. Example:
The following example enables Ring state in bridge GROUP (1): switch_a(config)#bridge 1 protocol ring switch_a(config)#
User’s Manual 144
Hardened Managed PoE Ethernet Switch
Set ring port:
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen. switch_a(config)#
2. Usage:
Use this command to set Ring port 1 and Ring port 2.
3. Command Syntax: ring set-port RING_PORT_1 RING_PORT_2
RING_PORT_1 Specify the Ring port 1.
RING_PORT_2 Specify the Ring port 2.
4. Example:
The following example sets the fe1 and fe2 as Ring port 1 and Ring port 2: switch_a(config)#ring set-port fe1 fe2 switch_a(config)#
User’s Manual 145
Hardened Managed PoE Ethernet Switch
VLAN
VLAN Mode Setting, 802.1Q VLAN Setting, 802.1Q Port Setting, Port Based
VLAN
802.1Q VLAN Setting
VLAN Database:
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen. switch_a(config)#
2. Usage:
Use vlan database command to enter the VLAN configuration mode.
3. Command Syntax: vlan database
4. Example:
The following example changes to VLAN configuration mode from Configure mode: switch_a(config)#vlan database switch_a(config-vlan)#
Add VLAN/Delete VLAN:
1. Command Mode: VLAN Configure mode
Logon to Configure Mode (Configure Terminal Mode).
Logon to VLAN Configure Mode.
The switch_a(config-vlan)# prompt will show on the screen. switch_a(config)#vlan database switch_a(config-vlan)#
2. Usage:
This command enables or disables the state of a particular VLAN on a bridge basis. Specifying the disable state causes all forwarding over the specified
VLAN ID on the specified bridge to cease. Specifying the enable state allows forwarding of frames on the specified VLAN-aware bridge.
3. Command Syntax: vlan VLANID bridge GROUP name VLAN_NAME state enable/disable no vlan VLANID bridge GROUP
VLANID The VID of the VLAN that will be enabled or disabled on the bridge
<2-4094>.
User’s Manual 146
Hardened Managed PoE Ethernet Switch
GROUP <1-1> The ID of the bridge-group on which the VLAN will be affected.
VLAN_NAME The ASCII name of the VLAN. Maximum length: 16 characters. enable Sets VLAN into an enable state. disable Sets VLAN into a disable state.
4. Example:
The following example enables the vlan VLANID (2) and name VLAN_NAME
(vlan2) of bridge GROUP (1): switch_a(config-vlan)#vlan 2 bridge 1 name vlan2 state enable switch_a(config-vlan)#
802.1Q Port Setting
Switchport mode access:
1. Command Mode: Interface mode
Logon to Configure Mode (Configure Terminal Mode).
Then logon to Interface mode. fe1 means port 1.
The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface fe1 switch_a(config-if)#
2. Usage:
Use switchport mode access command to set the switching characteristics of the Layer-2 interface to access mode, and classify untagged frames only.
Use the no switchport access command to reset the mode of the Layer-2 interface to access (default).
3. Command Syntax: switchport mode access no switchport access
4. Example:
The following example sets the switchport mode access of the interface fe1
(port 1): switch_a(config)#interface fe1 switch_a(config-if)#switchport mode access switch_a(config-if)#
Switchport mode hybrid:
1. Command Mode: Interface mode
Logon to Configure Mode (Configure Terminal Mode).
Then logon to Interface mode.
User’s Manual 147
Hardened Managed PoE Ethernet Switch
fe1 means port 1.
The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface fe1 switch_a(config-if)#
2. Usage:
Use switchport mode hybrid command to set the switching characteristics of the Layer-2 interface as hybrid, and classify both tagged and untagged frames.
Use the no switchport hybrid command to reset the mode of the Layer-2 interface to access (default).
3. Command Syntax: switchport mode hybrid switchport mode hybrid acceptable-frame-type all/vlan-tagged no switchport hybrid
all Set all frames can be received.
vlan-tagged Set vlan-tagged frames can only be received.
4. Example:
The following example sets the switchport mode hybrid of the interface fe1
(port 1) and all frames to be received on interface fe1 (port 1): switch_a(config)#interface fe1 switch_a(config-if)#switchport mode hybrid acceptable-frame-type all switch_a(config-if)#
Switchport mode trunk:
1. Command Mode: Interface mode
Logon to Configure Mode (Configure Terminal Mode).
Then logon to Interface mode. fe1 means port 1.
The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface fe1 switch_a(config-if)#
2. Usage:
Use switchport mode trunk command to set the switching characteristics of the Layer-2 interface as trunk, and specify only tagged frames.
Use the no switchport trunk command to reset the mode of the Layer-2 interface to access (default).
3. Command Syntax: switchport mode trunk no switchport trunk
4. Example:
User’s Manual 148
Hardened Managed PoE Ethernet Switch
The following example sets the switchport mode trunk of the interface fe1
(port 1): switch_a(config)#interface fe1 switch_a(config-if)#switchport mode trunk switch_a(config-if)#
Switchport hybrid allowed vlan:
1. Command Mode: Interface mode
Logon to Configure Mode (Configure Terminal Mode).
Then logon to Interface mode. fe1 means port 1.
The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface fe1 switch_a(config-if)#
2. Usage:
Use this command to set the switching characteristics of the Layer-2 interface to hybrid. Both tagged and untagged frames will be classified over hybrid interfaces.
Use the no parameter to turn off allowed hybrid switching.
3. Command Syntax: switchport hybrid allowed vlan all switchport hybrid allowed vlan none switchport hybrid allowed vlan add VLANID egress-tagged enable/disable switchport hybrid allowed vlan remove VLANID no switchport hybrid vlan all Allow all VLANs to transmit and receive through the Layer-2 interface. none Allow no VLANs to transmit and receive through the Layer-2 interface. add Add a VLAN to the member set. remove Remove a VLAN from the member set.
VLANID <2-4094> The ID of the VLAN or VLANs that will be added to, or removed from, the Layer-2 interface.
For a VLAN range, specify two VLAN numbers: lowest, then highest number in the range, separated by a hyphen.
For a VLAN list, specify the VLAN numbers separated by commas. egress-tagged enable Enable the egress tagging for the outgoing frames. disable Disable the egress tagging for the outgoing frames.
4. Example:
The following example specifies to add the interface fe1 (port 1) to VLANID
(2) and enable the egress-tagged for the outgoing frames on interface fe1
(port 1): switch_a(config)#interface fe1 switch_a(config-if)#switchport hybrid allowed vlan add 2 egress-tagged enable
User’s Manual 149
Hardened Managed PoE Ethernet Switch
switch_a(config-if)#
Switchport trunk allowed vlan:
1. Command Mode: Interface mode
Logon to Configure Mode (Configure Terminal Mode).
Then logon to Interface mode. fe1 means port 1.
The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface fe1 switch_a(config-if)#
2. Usage:
Use this command to set the switching characteristics of the Layer-2 interface to trunk. The all parameter indicates that any VLAN ID is part of its port’s member set. The none parameter indicates that no VLAN ID is configured on this port. The add and remove parameters will add and remove VLAN IDs to/from the port’s member set.
Use the no parameter to remove all VLAN IDs configured on this port.
3. Command Syntax: switchport trunk allowed vlan all switchport trunk allowed vlan none switchport trunk allowed vlan add VLANID switchport trunk allowed vlan remove VLANID switchport trunk allowed vlan except VLANID no switchport trunk vlan all Allow all VLANs to transmit and receive through the Layer-2 interface. none Allow no VLANs to transmit and receive through the Layer-2 interface. add Add a VLAN to transmit and receive through the Layer-2 interface. remove Remove a VLAN from transmit and receive through the Layer-2 interface. except All VLANs, except the VLAN for which the ID is specified, are part of its ports member set.
VLANID <2-4094> The ID of the VLAN or VLANs that will be added to, or removed from, the Layer-2 interface. A single VLAN, VLAN range, or VLAN list can be set.
For a VLAN range, specify two VLAN numbers: lowest, then highest number in the range, separated by a hyphen.
For a VLAN list, specify the VLAN numbers separated by commas.
4. Example:
The following example specifies to add the interface fe1 (port 1) to VLANID
(2): switch_a(config)#interface fe1 switch_a(config-if)#switchport trunk allowed vlan add 2 switch_a(config-if)#
User’s Manual 150
Hardened Managed PoE Ethernet Switch
Port Based VLAN
Switchport portbase add/remove vlan:
1. Command Mode: Interface mode
Logon to Configure Mode (Configure Terminal Mode).
Then logon to Interface mode. fe1 means port 1.
The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface fe1 switch_a(config-if)#
2. Usage:
Use this command to set or remove the default VLAN for the interface.
3. Command Syntax: switchport portbase add|remove vlan VLANID
VLANID The ID of the VLAN will be added to or removed from the Layer-2 interface.
4. Example:
The following example specifies to add the interface fe1 (port 1) to VLANID
(2): switch_a(config)#interface fe1 switch_a(config-if)#switchport portbase add vlan 2 switch_a(config-if)#
User’s Manual 151
Hardened Managed PoE Ethernet Switch
QoS
Global Configuration, 802.1p Priority, DSCP
Global Configuration
QoS:
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen. switch_a(config)#
2. Usage:
Use mls qos enable command to globally enable QoS.
Use the no mls qos command to globally disable QoS.
3. Command Syntax: mls qos enable
(no) mls qos
4. Example:
The following example globally enables QoS on the switch: switch_a(config)#mls qos enable switch_a(config)#
Trust:
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen. switch_a(config)#
2. Usage:
Use mls qos trust command to turn on QoS trust CoS or DSCP.
Use the no mls qos trust command to turn off QoS trust CoS or DSCP.
3. Command Syntax:
(no) mls qos trust cos/dscp
cos Class of Service.
dscp Differentiated Service Code Point.
4. Example:
The following example turns on QoS trust CoS on the switch: switch_a(config)#mls qos trust cos switch_a(config)#
User’s Manual 152
Hardened Managed PoE Ethernet Switch
Strict Priority:
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen. switch_a(config)#
2. Usage:
Use priority-queue out command to enable the egress expedite queue.
Use the no priority-queue out command to disable the egress expedite queue.
3. Command Syntax:
(no) priority-queue out
4. Example:
The following example enables the egress expedite queue on the switch: switch_a(config)#priority-queue out switch_a(config)#
Weighted Round Robin:
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen. switch_a(config)#
2. Usage:
Use wrr-queue bandwidth command to specify the bandwidth ratios of the transmit queues.
3. Command Syntax: wrr-queue bandwidth WRR_WTS
WRR_WTS Weighted Round Robin (WRR) weights for the 4 queues (4 values separated by spaces). Range is 1-55.
4. Example:
The following example specifies the bandwidth ratios of the transmit queues on the switch: switch_a(config)#wrr-queue bandwidth 1 2 4 8 switch_a(config)#
User’s Manual 153
Hardened Managed PoE Ethernet Switch
802.1p Priority
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen. switch_a(config)#
2. Usage:
Use wrr-queue cos-map command to specify CoS values for a queue.
3. Command Syntax: wrr-queue cos-map QUEUE_ID COS_VALUE
QUEUE_ID Queue ID. Range is 0-3.
COS_VALUE CoS values. Up to 8 values (separated by spaces). Range is
0-7.
4. Example:
The following example shows mapping CoS values 0 and 1 to queue 1 on the switch: switch_a(config)#wrr-queue cos-map 1 0 1 switch_a(config)#
DSCP
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen. switch_a(config)#
2. Usage:
Use mls qos map dscp-queue command to map the DSCP values to a queue.
3. Command Syntax: mls qos map dscp-queue DSCP_VALUE to QUEUE_ID
DSCP_VALUE DSCP values. Up to 8 values (separated by spaces). Range is 0-63.
QUEUE_ID Queue ID. Range is 0-3.
4. Example:
The following example shows mapping DSCP values 0 to 3 to queue 1 on the switch: switch_a(config)#mls qos map dscp-queue 0 1 2 3 to 1 switch_a(config)#
User’s Manual 154
Hardened Managed PoE Ethernet Switch
SNMP
SNMP General Setting, SNMP v1/v2c, SNMP v3
SNMP General Setting
SNMP Status:
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen. switch_a(config)#
2. Usage:
Use snmp-server enable command to enable and no snmp-server enable command to disable SNMP to the switch.
3. Command Syntax:
(no) snmp-server enable
4. Example:
The following example enables SNMP to the switch: switch_a(config)#snmp-server enable switch_a(config)#
Description:
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen. switch_a(config)#
2. Usage:
Use snmp-server description command to specify and no snmp-server
description command to remove description for SNMP.
3. Command Syntax: snmp-server description DESCRIPTION no snmp-server description
DESCRIPTION The description for SNMP.
4. Example:
The following example specifies description (description) for SNMP: switch_a(config)#snmp-server description description switch_a(config)#
User’s Manual 155
Hardened Managed PoE Ethernet Switch
Location:
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen. switch_a(config)#
2. Usage:
Use snmp-server location command to specify and no snmp-server
location command to remove location for SNMP.
3. Command Syntax: snmp-server location LOCATION no snmp-server location
LOCATION The location for SNMP.
4. Example:
The following example specifies location (location) for SNMP: switch_a(config)#snmp-server location location switch_a(config)#
Contact:
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen. switch_a(config)#
2. Usage:
Use snmp-server contact command to specify and no snmp-server
contact command to remove contact for SNMP.
3. Command Syntax: snmp-server contact CONTACT no snmp-server contact
CONTACT The contact for SNMP.
4. Example:
The following example specifies contact (contact) for SNMP: switch_a(config)#snmp-server contact contact switch_a(config)#
Trap Community Name:
User’s Manual 156
Hardened Managed PoE Ethernet Switch
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen. switch_a(config)#
2. Usage:
Use this command to specify trap community name for SNMP.
Use the no parameter with this command to remove trap community name for
SNMP.
3. Command Syntax: snmp-server trap-community <1-5> NAME no snmp-server trap-community <1-5>
<1-5> The trap community 1-5.
NAME The trap community name for SNMP.
4. Example:
The following example specifies trap community name 1 (name) for SNMP: switch_a(config)#snmp-server trap-community 1 name switch_a(config)#
Trap Host IP Address:
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen. switch_a(config)#
2. Usage:
Use this command to specify trap host IP address for SNMP.
Use the no parameter with this command to remove trap host IP address for
SNMP.
3. Command Syntax: snmp-server trap-ipaddress <1-5> IP-ADDRESS no snmp-server trap-ipaddress <1-5>
<1-5> The trap host IP address 1-5.
IP-ADDRESS The trap host IP address for SNMP. A.B.C.D specifies the IP address.
4. Example:
The following example specifies trap host 1 IP address (192.168.1.20) for
SNMP: switch_a(config)#snmp-server trap-ipaddress 1 192.168.1.20 switch_a(config)#
User’s Manual 157
Hardened Managed PoE Ethernet Switch
Cold Start Trap:
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen. switch_a(config)#
2. Usage:
Use snmp-server trap-type enable coldStart command to enable cold start trap for SNMP.
Use the no snmp-server trap-type enable coldStart command to disable cold start trap for SNMP.
3. Command Syntax:
(no) snmp-server trap-type enable coldStart
4. Example:
The following example enables cold start trap for SNMP: switch_a(config)#snmp-server trap-type enable coldStart switch_a(config)#
Warm Start Trap:
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen. switch_a(config)#
2. Usage:
Use snmp-server trap-type enable warmStart command to enable warm start trap for SNMP.
Use the no snmp-server trap-type enable warmStart command to disable warm start trap for SNMP.
3. Command Syntax:
(no) snmp-server trap-type enable warmStart
4. Example:
The following example enables warm start trap for SNMP: switch_a(config)#snmp-server trap-type enable warmStart switch_a(config)#
Link Down Trap:
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
User’s Manual 158
Hardened Managed PoE Ethernet Switch
The switch_a(config)# prompt will show on the screen. switch_a(config)#
2. Usage:
Use snmp-server trap-type enable linkDown command to enable link down trap for SNMP.
Use the no snmp-server trap-type enable linkDown command to disable link down trap for SNMP.
3. Command Syntax:
(no) snmp-server trap-type enable linkDown
4. Example:
The following example enables link down trap for SNMP: switch_a(config)#snmp-server trap-type enable linkDown switch_a(config)#
Link Up Trap:
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen. switch_a(config)#
2. Usage:
Use snmp-server trap-type enable linkUp command to enable link up trap for SNMP.
Use the no snmp-server trap-type enable linkUp command to disable link up trap for SNMP.
3. Command Syntax:
(no) snmp-server trap-type enable linkUp
4. Example:
The following example enables link up trap for SNMP: switch_a(config)#snmp-server trap-type enable linkUp switch_a(config)#
Authentication Failure Trap:
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen. switch_a(config)#
2. Usage:
User’s Manual 159
Hardened Managed PoE Ethernet Switch
Use snmp-server trap-type enable authenticationFailure command to enable authentication failure trap for SNMP.
Use the no snmp-server trap-type enable authenticationFailure command to disable authentication failure trap for SNMP.
3. Command Syntax:
(no) snmp-server trap-type enable authenticationFailure
4. Example:
The following example enables authentication failure trap for SNMP: switch_a(config)#snmp-server trap-type enable authenticationFailure switch_a(config)#
Topology Change Trap:
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen. switch_a(config)#
2. Usage:
Use snmp-server trap-type enable topologyChange command to enable topology change trap for SNMP.
Use the no snmp-server trap-type enable topologyChange command to disable topology change trap for SNMP.
3. Command Syntax:
(no) snmp-server trap-type enable topologyChange
4. Example:
The following example enables topology change trap for SNMP: switch_a(config)#snmp-server trap-type enable topologyChange switch_a(config)#
SNMP v1/v2c
Get Community Name:
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen. switch_a(config)#
2. Usage:
Use snmp-server community get command to specify and no
snmp-server community get command to remove get community name for
SNMP.
User’s Manual 160
Hardened Managed PoE Ethernet Switch
3. Command Syntax: snmp-server community get NAME no snmp-server community get
NAME The get community name for SNMP.
4. Example:
The following example specifies get community name (name) for SNMP: switch_a(config)#snmp-server community get name switch_a(config)#
Set Community Name:
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen. switch_a(config)#
2. Usage:
Use snmp-server community set command to specify and no
snmp-server community set command to remove set community name for
SNMP.
3. Command Syntax: snmp-server community set NAME no snmp-server community set
NAME The set community name for SNMP.
4. Example:
The following example specifies set community name (name) for SNMP: switch_a(config)#snmp-server community set name switch_a(config)#
SNMP v3
SNMPv3 No-Auth:
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen. switch_a(config)#
2. Usage:
Add a user using snmp v3 with read-only or read-write access mode and without authentication. Use the no form of the command to delete this user.
3. Command Syntax:
User’s Manual 161
Hardened Managed PoE Ethernet Switch
(no) snmp-server v3-user USERNAME (ro|rw) noauth
USERNAME Specify a user name. ro read-only access mode rw read-write access mode
4. Example:
The following example adds a user (myuser) using snmp v3 with read-only access mode and without authentication: switch_a(config)#snmp-server v3-user myuser ro noauth switch_a(config)#
SNMPv3 Auth-MD5, SNMPv3 Auth-SHA:
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen. switch_a(config)#
2. Usage:
Add a user using snmp v3 with read-only or read-write access mode and with
MD5 or SHA authentication. Use the no form of the command to delete this user.
3. Command Syntax:
(no) snmp-server v3-user USERNAME (ro | rw) auth (md5 | sha)
AUTH_PASSWORD
USERNAME Specify a user name. ro read-only access mode rw read-write access mode md5 authentication method sha authentication method
AUTH_PASSWORD authentication password
4. Example:
The following example adds a user (myuser) using snmp v3 with read-write access mode and MD5 authentication (mypassword): switch_a(config)#snmp-server v3-user myuser rw auth md5 mypassword switch_a(config)#
SNMPv3 Priv Auth-MD5, SNMPv3 Priv Auth-SHA:
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen. switch_a(config)#
User’s Manual 162
Hardened Managed PoE Ethernet Switch
2. Usage:
Add a user using snmp v3 with read-only or read-write access mode, MD5 or
SHA authentication, and privacy. Use the no form of the command to delete this user.
3. Command Syntax:
(no) snmp-server v3-user USERNAME (ro | rw) priv auth (md5 | sha)
AUTH_PASSWORD des PRIV_PASS_PHRASE
USERNAME Specify a user name. ro read-only access mode rw read-write access mode md5 authentication method sha authentication method
AUTH_PASSWORD authentication password
PRIV_PASS_PHRASE encryption pass phrase
4. Example:
The following example adds a user (myuser) using snmp v3 with read-write access mode, MD5 authentication (mypassword), and encryption pass phrase (mypassphrase): switch_a(config)#snmp-server v3-user myuser rw priv md5 mypassword des mypassphrase switch_a(config)#
User’s Manual 163
Hardened Managed PoE Ethernet Switch
802.1x
Radius Configuration, Port Authentication
Radius Configuration
Radius Status:
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen. switch_a(config)#
2. Usage:
Use dot1x system-auth-ctrl command to globally enable authentication.
Use no dot1x system-auth-ctrl command to globally disable authentication.
3. Command Syntax:
(no) dot1x system-auth-ctrl
4. Example:
The following example globally enables authentication: switch_a(config)#dot1x system-auth-ctrl switch_a(config)#
Radius Server IP:
Radius Server Port:
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen. switch_a(config)#
2. Usage:
Use this command to specify the IP address of the remote radius server host and assign authentication and accounting destination port number.
3. Command Syntax:
(no) radius-server host IP-ADDRESS auth-port PORT
IP-ADDRESS A.B.C.D specifies the IP address of the radius server host.
PORT specifies the UDP destination port for authentication requests. The host is not used for authentication if set to 0.
4. Example:
The following example specifies the IP address (192.168.1.100) of the remote radius server host and assigns authentication and accounting
User’s Manual 164
Hardened Managed PoE Ethernet Switch
destination port number (1812): switch_a(config)#radius-server host 192.168.1.100 auth-port 1812 switch_a(config)#
Secret Key:
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen. switch_a(config)#
2. Usage:
Use this command to set the shared secret key between a Radius server and a client.
3. Command Syntax:
(no) radius-server host IP-ADDRESS key KEY
IP-ADDRESS A.B.C.D specifies the IP address of the radius server host.
KEY specifies the secret key shared among the radius server and the
802.1x client.
4. Example:
The following example specifies the IP address (192.168.1.100) of the remote radius server host and set the secret key (ipi) shared among the radius server and the 802.1x client: switch_a(config)#radius-server host 192.168.1.100 key ipi switch_a(config)#
Timeout:
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen. switch_a(config)#
2. Usage:
Use this command to specify the number of seconds a Switch waits for a reply to a radius request before retransmitting the request.
3. Command Syntax: radius-server timeout SEC no radius-server timeout
SEC <1-1000> The number of seconds for a Switch to wait for a server host to reply before timing out. Enter a value in the range 1 to 1000.
4. Example:
User’s Manual 165
Hardened Managed PoE Ethernet Switch
The following example specifies 20 seconds for the Switch to wait for a server host to reply before timing out: switch_a(config)#radius-server timeout 20 switch_a(config)#
Retransmit:
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen. switch_a(config)#
2. Usage:
Use this command to specify the number of times the Switch transmits each radius request to the server before giving up.
3. Command Syntax: radius-server retransmit RETRIES no radius-server retransmit
RETRIES <1-100> Specifies the retransmit value. Enter a value in the range
1 to 100.
4. Example:
The following example specifies the retransmit value 12: switch_a(config)#radius-server retransmit 12 switch_a(config)#
Port Authentication
Authentication State:
1. Command Mode: Interface mode
Logon to Configure Mode (Configure Terminal Mode).
Then logon to Interface mode. fe1 means port 1.
The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface fe1 switch_a(config-if)#
2. Usage:
Use dot1x reauthetication command to enable reauthentication on a port.
Use no dot1x reauthetication command to disable reauthentication on a port.
3. Command Syntax:
(no) dot1x reauthentication
User’s Manual 166
Hardened Managed PoE Ethernet Switch
4. Example:
The following example specifies to enable reauthetication on the interface fe1
(port 1): switch_a(config)#interface fe1 switch_a(config-if)#dot1x reauthentication switch_a(config-if)#
Port Control:
1. Command Mode: Interface mode
Logon to Configure Mode (Configure Terminal Mode).
Then logon to Interface mode. fe1 means port 1.
The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface fe1 switch_a(config-if)#
2. Usage:
Use this command to force a port state.
Use no dot1x port-control command to remove a port from the 802.1x management.
3. Command Syntax: dot1x port-control auto|force-authorized|force-unauthorized no dot1x port-control
auto Specify to enable authentication on port.
force-authorized Specify to force a port to always be in an authorized state.
force-unauthorized Specify to force a port to always be in an unauthorized state.
4. Example:
The following example specifies to enable authetication on the interface fe1
(port 1): switch_a(config)#interface fe1 switch_a(config-if)#dot1x port-control auto switch_a(config-if)#
Periodic Reauthentication:
Reauthentication Period:
1. Command Mode: Interface mode
Logon to Configure Mode (Configure Terminal Mode).
Then logon to Interface mode. fe1 means port 1.
The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface fe1
User’s Manual 167
Hardened Managed PoE Ethernet Switch
switch_a(config-if)#
2. Usage:
Use this command to set the interval between reauthorization attempts.
Use no dot1x timeout re-authperiod command to delete the interval between reauthorization attempts.
3. Command Syntax: dot1x timeout re-authperiod SECS no dot1x timeout re-authperiod
SECS <1-4294967295> Specify the seconds between reauthorization attempts. The default time is 3600 seconds.
4. Example:
The following example specifies to set the interval 25 seconds between reauthorization attempts: switch_a(config)#interface fe1 switch_a(config-if)#dot1x timeout re-authperiod 25 switch_a(config-if)#
User’s Manual 168
Hardened Managed PoE Ethernet Switch
Other Protocols
GVRP, IGMP Snooping, NTP
GVRP
GVRP:
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen. switch_a(config)#
2. Usage:
Use set gvrp enable bridge command to enable (set) and set gvrp disable
bridge command to disable (reset) GVRP globally for the bridge instance.
This command does not enable/disable GVRP in all ports of the bridge. After enabling GVRP globally, use the set port gvrp enable command to enable
GVRP on individual ports of the bridge.
3. Command Syntax: set gvrp enable bridge GROUP set gvrp disable bridge GROUP
GROUP Bridge-group ID used for bridging.
4. Example:
The following example globally enables GVRP to bridge GROUP (1): switch_a(config)#set gvrp enable bridge 1 switch_a(config)#
Dynamic VLAN creation:
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen. switch_a(config)#
2. Usage:
Use set gvrp dynamic-vlan-creation enable bridge command to enable and set gvrp dynamic-vlan-creation disable bridge command to disable dynamic VLAN creation for a specific bridge instance.
3. Command Syntax: set gvrp dynamic-vlan-creation enable bridge GROUP set gvrp dynamic-vlan-creation disable bridge GROUP
GROUP Bridge-group ID used for bridging.
User’s Manual 169
Hardened Managed PoE Ethernet Switch
4. Example:
The following example enables dynamic VLAN creation for bridge GROUP
(1): switch_a(config)#set gvrp dynamic-vlan-creation enable bridge 1 switch_a(config)#
Per port setting:
GVRP:
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen. switch_a(config)#
2. Usage:
Use set port gvrp enable command to enable and set port gvrp disable command to disable GVRP on a port or all ports in a bridge.
3. Command Syntax: set port gvrp enable all/IFNAME set port gvrp disable all/IFNAME all All ports added to recently configured bridge.
IFNAME The name of the interface.
4. Example:
The following example enables GVRP on the interface fe1 (port 1): switch_a(config)#set port gvrp enable fe1 switch_a(config)#
Per port setting:
GVRP applicant:
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen. switch_a(config)#
2. Usage:
Use this command to set the GVRP applicant state to normal or active.
3. Command Syntax: set gvrp applicant state active/normal IFNAME active Active state normal Normal state
IFNAME Name of the interface.
User’s Manual 170
Hardened Managed PoE Ethernet Switch
4. Example:
The following example sets GVRP applicant state to active on the interface fe1 (port 1): switch_a(config)#set gvrp applicant state active fe1 switch_a(config)#
Per port setting:
GVRP registration:
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen. switch_a(config)#
2. Usage:
Use this command to set GVRP registration to normal, fixed, and forbidden registration mode for a given port.
3. Command Syntax: set gvrp registration normal IF_NAME set gvrp registration fixed IF_NAME set gvrp registration forbidden IF_NAME normal Specify dynamic GVRP multicast registration and deregistration on the port. fixed Specify the multicast groups currently registered on the switch are applied to the port, but any subsequent registrations or deregistrations do not affect the port. Any registered multicast groups on the port are not deregistered based on the GARP timers. forbidden Specify that all GVRP multicasts are deregistered, and prevent any further GVRP multicast registration on the port.
IF_NAME The name of the interface.
4. Example:
The following example sets GVRP registration to fixed registration mode on the interface fe1 (port 1): switch_a(config)#set gvrp registration fixed fe1 switch_a(config)#
IGMP Snooping
IGMP mode:
Querier:
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen.
User’s Manual 171
Hardened Managed PoE Ethernet Switch
switch_a(config)#
2. Usage:
Use ip igmp snooping querier command to enable IGMP querier operation on a subnet (VLAN) when no multicast routing protocol is configured in the subnet (VLAN). When enabled, the IGMP Snooping querier sends out periodic IGMP queries for all interfaces on that VLAN.
Use the no ip igmp snooping querier command to disable IGMP querier configuration.
3. Command Syntax:
(no) ip igmp snooping querier
4. Example:
The following example enables IGMP snooping querier: switch_a(config)# ip igmp snooping querier switch_a(config)#
IGMP mode:
Passive:
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen. switch_a(config)#
2. Usage:
Use ip igmp snooping command to enable IGMP Snooping. This command is given in the Global Config mode. IGMP Snooping is enabled at the switch level.
Use the no ip igmp snooping command to globally disable IGMP Snooping.
3. Command Syntax:
(no) ip igmp snooping enable
4. Example:
The following example enables IGMP snooping on the switch: switch_a(config)# ip igmp snooping enable switch_a(config)#
IGMP version:
1. Command Mode: Interface mode
Logon to Configure Mode (Configure Terminal Mode).
Then logon to Interface mode. vlan1.1 means vlan 1.
User’s Manual 172
Hardened Managed PoE Ethernet Switch
The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface vlan1.1 switch_a(config-if)#
2. Usage:
Use ip igmp version command to set the current IGMP protocol version on an interface.
To return to the default version, use the no ip igmp version command.
3. Command Syntax: ip igmp version VERSION no ip igmp version
VERSION IGMP protocol version number.
4. Example:
The following example sets the IGMP protocol version 3 on vlan1.1: switch_a(config)#interface vlan1.1 switch_a(config-if)#ip igmp version 3 switch_a(config-if)#
Fast-leave:
1. Command Mode: Interface mode
Logon to Configure Mode (Configure Terminal Mode).
Then logon to Interface mode. vlan1.1 means vlan 1.
The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface vlan1.1 switch_a(config-if)#
2. Usage:
Use ip igmp snooping fast-leave command to enable IGMP Snooping fast-leave processing. Fast-leave processing is analogous to immediate leave processing; the IGMP group-membership is removed, as soon as an
IGMP leave group message is received without sending out a group-specific query.
Use the no ip igmp snooping fast-leave command to disable fast-leave processing.
3. Command Syntax:
(no) ip igmp snooping fast-leave
4. Example:
The following example enables IGMP snooping fast-leave on vlan1.1: switch_a(config)#interface vlan1.1 switch_a(config-if)#ip igmp snooping fast-leave switch_a(config-if)#
User’s Manual 173
Hardened Managed PoE Ethernet Switch
IGMP querier:
Query-interval:
1. Command Mode: Interface mode
Logon to Configure Mode (Configure Terminal Mode).
Then logon to Interface mode. vlan1.1 means vlan 1.
The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface vlan1.1 switch_a(config-if)#
2. Usage:
Use ip igmp query-interval command to configure the frequency of sending
IGMP host query messages.
To return to the default frequency, use the no ip igmp query-interval command.
3. Command Syntax: ip igmp query-interval INTERVAL no ip igmp query-interval
INTERVAL <1-18000> Frequency (in seconds) at which IGMP host query messages are sent. Default: 125 seconds.
4. Example:
The following example changes the frequency of sending IGMP host-query messages to 2 minutes on vlan1.1: switch_a(config)#interface vlan1.1 switch_a(config-if)#ip igmp query-interval 120 switch_a(config-if)#
IGMP querier:
Max-response-time:
1. Command Mode: Interface mode
Logon to Configure Mode (Configure Terminal Mode).
Then logon to Interface mode. vlan1.1 means vlan 1.
The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface vlan1.1 switch_a(config-if)#
2. Usage:
Use ip igmp query-max-response-time command to configure the maximum response time advertised in IGMP queries.
User’s Manual 174
Hardened Managed PoE Ethernet Switch
To restore to the default value, use the no ip igmp
query-max-response-time command.
3. Command Syntax: ip igmp query-max-response-time RESPONSETIME no ip igmp query-max-response-time
RESPONSETIME <1-240> Maximum response time (in seconds) advertised in IGMP queries. Default: 10 seconds.
4. Example:
The following example configures a maximum response time of 8 seconds on
vlan1.1: switch_a(config)#interface vlan1.1 switch_a(config-if)#ip igmp query-max-response-time 8 switch_a(config-if)#
IGMP passive snooping:
Static mc router port:
1. Command Mode: Interface mode
Logon to Configure Mode (Configure Terminal Mode).
Then logon to Interface mode. vlan1.1 means vlan 1.
The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface vlan1.1 switch_a(config-if)#
2. Usage:
Use ip igmp snooping mrouter interface command to statically configure the specified VLAN constituent interface as a multicast router interface for
IGMP Snooping in that VLAN.
Use the no ip igmp snooping mrouter interface command to remove the static configuration of the interface as a multicast router interface.
3. Command Syntax:
(no) ip igmp snooping mrouter interface IFNAME
IFNAME Specify the name of the interface
4. Example:
The following example shows interface fe1 (port 1) statically configured to be a multicast router interface on vlan1.1: switch_a(config)#interface vlan1.1 switch_a(config-if)#ip igmp snooping mrouter interface fe1 switch_a(config-if)#
User’s Manual 175
Hardened Managed PoE Ethernet Switch
IGMP passive snooping:
Report suppression:
1. Command Mode: Interface mode
Logon to Configure Mode (Configure Terminal Mode).
Then logon to Interface mode. vlan1.1 means vlan 1.
The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface vlan1.1 switch_a(config-if)#
2. Usage:
Use ip igmp snooping report-suppression command to enable report suppression for IGMP versions 1 and 2.
Use the no ip igmp snooping report-suppression command to disable report suppression.
3. Command Syntax:
(no) ip igmp snooping report-suppression
4. Example:
The following example enables report suppression for IGMPv2 reports on
vlan1.1: switch_a(config)#interface vlan1.1 switch_a(config-if)#ip igmp version 2 switch_a(config-if)#ip igmp snooping report-suppression switch_a(config-if)#
NTP
RTC Time:
1. Command Mode: Exec mode or Privileged Exec mode
Logon to Exec Mode (View Mode) or Privileged Exec Mode (Enable Mode).
The switch_a> or switch_a# prompt will show on the screen. switch_a> switch_a#
2. Usage:
Use the show rtc time command to show RTC time.
3. Command Syntax: show rtc time
4. Example:
The following example shows the use of show rtc time to show RTC time: switch_a>show rtc time
User’s Manual 176
Hardened Managed PoE Ethernet Switch
Adjust RTC Time:
1. Command Mode: Privileged Exec mode
Logon to Privileged Exec Mode (Enable Mode).
The switch_a# prompt will show on the screen. switch_a#
2. Usage:
Use this command to configure the time of RTC.
3. Command Syntax: set clock YEAR MONTH DAY HOUR MINUTE SECOND
YEAR Specifies year from 2000 to 2037.
MONTH <1-12> Specifies from 1 to 12.
DAY <1-31> Specifies from 1 to 31.
HOUR <0-23> Specifies from 0 to 23.
MINUTE <0-59> Specifies from 0 to 59.
SECOND <0-59> Specifies from 0 to 59.
4. Example:
The following example sets the time of RTC as July/20/2015 12:30:50: switch_a#set clock 2015 7 20 12 30 50 switch_a#
NTP Status:
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen. switch_a(config)#
2. Usage:
Use ntp enable command to enable NTP for the Switch.
Use no ntp enable command to disable NTP for the Switch.
3. Command Syntax:
(no) ntp enable
4. Example:
The following example enables NTP for the Switch: switch_a(config)#ntp enable switch_a(config)#
User’s Manual 177
Hardened Managed PoE Ethernet Switch
NTP Server:
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen. switch_a(config)#
2. Usage:
Use this command to specify the IP address or Domain name of NTP server.
3. Command Syntax: ntp server IP-ADDRESS|DOMAIN-NAME
IP-ADDRESS A.B.C.D specifies the IP address of NTP server.
DOMAIN-NAME Specifies the Domain name of NTP server.
4. Example:
The following example specifies the IP address (192.168.1.100) of NTP server: switch_a(config)#ntp server 192.168.1.100 switch_a(config)#
Sync Time:
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen. switch_a(config)#
2. Usage:
Use ntp sync-time command to synchronize time with NTP server.
3. Command Syntax: ntp sync-time
4. Example:
The following example synchronizes time with NTP server: switch_a(config)#ntp sync-time switch_a(config)#
Time Zone:
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen. switch_a(config)#
2. Usage:
User’s Manual 178
Hardened Managed PoE Ethernet Switch
Use this command to to set time zone.
3. Command Syntax: clock timezone TIMEZONE
TIMEZONE Specifies the time zone. (Please refer the Appendix B)
4. Example:
The following example sets time zone (Canada/Yukon): switch_a(config)#clock timezone YST9YDT switch_a(config)#
Polling Interval:
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen. switch_a(config)#
2. Usage:
Use this command to specify the polling interval.
3. Command Syntax: ntp polling-interval MINUTE
MINUTE <1-10080> The polling interval. Enter a value in the range 1 to
10080 minutes.
4. Example:
The following example specifies the polling interval 60 minutes: switch_a(config)#ntp polling interval 60 switch_a(config)#
Daylight Saving Mode:
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen. switch_a(config)#
2. Usage:
Use this command to enable daylight saving.
Use no clock summer-time command to disable daylight saving.
3. Command Syntax: clock summer-time TIMEZONE weekday WEEK DAY MONTH HOUR
MINUTE WEEK DAY MONTH HOUR MINUTE OFFSET
TIMEZONE Specifies the daylight saving timezone.
User’s Manual 179
Hardened Managed PoE Ethernet Switch
WEEK <1-5> Specifies starting/ending week of daylight savings time.
DAY <0-6> Specifies from Sunday to Saturday.
MONTH <1-12> Specifies from January to December.
HOUR <0-23> Specifies from 0 to 23.
MINUTE <0-59> Specifies from 0 to 59.
OFFSET <1-1440> Specifies from 1 to 1440 minutes. clock summer-time TIMEZONE date DAY MONTH HOUR MINUTE DAY
MONTH HOUR MINUTE OFFSET
TIMEZONE Specifies the daylight saving timezone.
DAY <1-31> Specifies from 1 to 31.
MONTH <1-12> Specifies from January to December.
HOUR <0-23> Specifies from 0 to 23.
MINUTE <0-59> Specifies from 0 to 59.
OFFSET <1-1440> Specifies from 1 to 1440 minutes. no clock summer-time
4. Example:
The following example sets clock summer-time TIMEZONE (onehour) as daylight saving offset 60 minutes from 4 April AM0:00 to 31 October AM0:00: switch_a(config)#clock summer-time onehour date 4 4 0 0 31 10 0 0 60 switch_a(config)#
User’s Manual 180
Hardened Managed PoE Ethernet Switch
Specifications
Applicable Standards
Cable
10BaseT
100BaseTX
1000BaseT
1000BaseSX/LX/BX
LED Indicators
Net Weight
Power Input
Power Consumption
IEEE 802.3 10BaseT
IEEE 802.3u 100BaseTX
IEEE 802.3ab 1000BaseT
IEEE 802.3z 1000BaseSX/LX
Store-and-Forward
Switching Method
Forwarding Rate
10BaseT
100BaseTX
1000BaseT/SX/LX/BX
Performance
Dimensions
Operating
Temperature
10 / 20Mbps half / full-duplex
100 / 200Mbps half / full-duplex
2000Mbps full-duplex
14,880pps for 10Mbps
148,810pps for 100Mbps
1,488,100pps for 1000Mbps
2-pair UTP/STP Cat. 3, 4, 5 Up to 328ft. (100m)
2-pair UTP/STP Cat. 5 Up to 328ft. (100m)
4-pair UTP/STP Cat. 5 Up to 328ft. (100m)
MMF (50 or 62.5μm), SMF (9 or 10μm)
Per unit – Power
Per port –
10/100TX (PoE): Link/ACT, PoE
10/100TX: Link/ACT
10/100/1000TX, 1000SX/LX/BX: Link/ACT, SFP
7.87” (W) x 5.28” (D) x 1.97” (H)
(200mm (W) x 134mm (D) x 50mm (H))
3.3lbs. (1.5Kg)
Terminal Block: 47~57VDC
17.7W Max.
-40℉ to 167℉ (-40℃ to 75℃)
Tested for functional operation @
-40℉ to 185℉ (-40℃ to 85℃)
-40℉ to 185℉ (-40℃ to 85℃)
Storage Temperature
Humidity
Safety
EMI
5%-95% non-condensing
UL508
EMS
FCC Part 15, Class A
EN61000-6-4: EN55022, EN61000-3-2, EN61000-3-3
EN61000-6-2:
EN61000-4-2 (ESD Standard)
EN61000-4-3 (Radiated RFI Standards)
EN61000-4-4 (Burst Standards)
EN61000-4-5 (Surge Standards)
EN61000-4-6 (Induced RFI Standards)
EN61000-4-8 (Magnetic Field Standards)
Environmental Test
Compliance
IEC60068-2-6 Fc (Vibration Resistance)
IEC60068-2-27 Ea (Shock)
IEC60068-2-32 Ed (Free Fall)
NEMA TS1/2 Environmental requirements for traffic control equipment
User’s Manual 181
Appendix A
DB9 DCE pin assignment
Pin no. Name
1 DCD
2
3
4
5
RxD
TxD
---
GND
6
7
8
9
DSR
---
CTS
---
Hardened Managed PoE Ethernet Switch
RS232 Signal name
Data Carrier detect
Received data
Transmit data
N/C
Signal ground
Data set Ready
N/C
Clear to send
N/C
User’s Manual 182
Hardened Managed PoE Ethernet Switch
Appendix B
Time Zone
Europe
MEZ-1MESZ
Country and City Lists
MET-1METDST
EET-2EETDST
GMT0BST
WET0WETDST
PWT0PST
MST-3MDT
EUT-1EUTDST
EUT-2EUTDST
EUT-3EUTDST
EUT-4EUTDST
EUT-6EUTDST
EUT-8EUTDST
Russian Federation
RFT-2RFTDST
RFT-3RFTDST
RFT-4RFTDST
Europe/Vienna, Europe/Berlin,
Europe/Zurich
Africa/Tunis, CET, MET, Europe/Tirane,
Europe/Andorra, Europe/Brussels,
Europe/Prague, Europe/Copenhagen,
Europe/Paris, Europe/Gibraltar,
Europe/Budapest, Europe/Rome,
Europe/Vaduz, Europe/Luxembourg,
Europe/Malta, Europe/Monaco,
Europe/Amsterdam, Europe/Oslo,
Europe/Warsaw, Europe/Belgrade,
Europe/Madrid, Africa/Ceuta,
Europe/Stockholm, Europe/Vatican,
Europe/San_Marino, Arctic/Longyearbyen,
Atlantic/Jan_Mayen, Europe/Ljubljana,
Europe/Sarajevo, Europe/Skopje,
Europe/Zagreb, Europe/Bratislava, Poland
Asia/Nicosia, EET, Europe/Minsk,
Europe/Sofia, Europe/Athens,
Europe/Vilnius, Europe/Chisinau,
Europe/Istanbul, Europe/Kiev,
Europe/Uzhgorod, Europe/Zaporozhye,
Europe/Nicosia, Asia/Istanbul,
Europe/Tiraspol, Turkey
Europe/London, Europe/Dublin, Eire,
Europe/Belfast, GB, GB-Eire
WET, Atlantic/Faeroe, Atlantic/Madeira,
Atlantic/Canary
Europe/Lisbon, Portugal
Europe/Moscow, W-SU
America/Scoresbysund, Atlantic/Azores
Asia/Beirut, Europe/Simferopol
Asia/Tbilisi
Europe/Samara
Asia/Almaty, Asia/Qyzylorda
Asia/Ulaanbaatar
Europe/Kaliningrad
Europe/Moscow
Asia/Yerevan, Asia/Baku, Asia/Oral,
Asia/Ashkhabad
User’s Manual 183
Hardened Managed PoE Ethernet Switch
RFT-5RFTDST
RFT-6RFTDST
RFT-7RFTDST
RFT-8RFTDST
RFT-9RFTDST
RFT-10RFTDST
RFT-11RFTDST
RFT-12RFTDST
North America
PST8PDT
Asia/Aqtobe, Asia/Aqtau, Asia/Bishkek,
Asia/Yekaterinburg
Asia/Omsk, Asia/Novosibirsk
Asia/Hovd, Asia/Krasnoyarsk
Asia/Irkutsk, Asia/Chungking,
Asia/Ulan_Bator
Asia/Choibalsan, Asia/Yakutsk
Asia/Vladivostok
Asia/Sakhalin, Asia/Magadan
Asia/Kamchatka, Asia/Anadyr
MST7MDT
MST7
CST6CDT
EST5EDT
AST4ADT
EST5
America/Los_Angeles, US/Pacific-New,
PST8PDT, US/Pacific, SystemV/PST8PDT
America/Denver, America/Boise,
America/Cambridge_Bay,
America/Shiprock, MST7MDT, Navajo,
US/Mountain, SystemV/MST7MDT
America/Phoenix, MST, US/Arizona,
SystemV/MST7
America/Chicago,
America/North_Dakota/Center,
America/Menominee, America/Costa_Rica,
America/Managua, CST6CDT, US/Central,
SystemV/CST6CDT
America/New_York,
America/Kentucky/Louisville,
America/Kentucky/Monticello,
America/Detroit, America/Pangnirtung,
America/Louisville, EST5EDT, US/Eastern,
US/Michigan, SystemV/EST5EDT
America/Thule, Atlantic/Bermuda,
SystemV/AST4ADT
America/Coral_Harbour, America/Cayman,
America/Jamaica,
America/Panama, EST, Jamaica,
SystemV/EST5
AST10ADT
YST9YDT
NST3:30NDT
NAST3NADT
NAST9NADT
America/Adak, America/Atka, US/Aleutian
Canada/Yukon
America/St_Johns, Canada/Newfoundland
America/Godthab, America/Miquelon
Pacific/Pitcairn, America/Juneau,
America/Yakutat, America/Anchorage,
America/Nome, US/Alaska,
SystemV/YST9YDT, SystemV/PST8
South America & Central America
TTST4 America/Port_of_Spain
SAT3 America/Argentina/Buenos_Aires,
User’s Manual 184
Hardened Managed PoE Ethernet Switch
EBST3EBDT
WBST4WBDT
ACRE5
NORO2
CST4CDT
America/Argentina/Cordoba,
America/Argentina/Tucuman,
America/Argentina/La_Rioja,
America/Argentina/San_Juan,
America/Argentina/Jujuy,
America/Argentina/Catamarca,
America/Argentina/Mendoza,
America/Argentina/Rio_Gallegos,
America/Argentina/Ushuaia,
America/Argentina/ComodRivadavia,
America/Buenos_Aires, America/Cordoba,
America/Jujuy, America/Mendoza
America/Fortaleza, America/Recife,
America/Araguaina, America/Maceio,
America/Bahia, America/Sao_Paulo,
America/Cuiaba, America/Montevideo,
America/Catamarca, America/Rosario,
Brazil/East
America/Campo_Grande,
America/Boa_Vista, America/Manaus,
Atlantic/Stanley, America/Asuncion,
Brazil/West
America/Rio_Branco, America/Porto_Acre,
Brazil/Acre
America/Noronha, Brazil/DeNoronha
Antarctica/Palmer, America/Santiago,
Chile/Continental
Pacific/Easter, Chile/EasterIsland EIST6EIDT
Asia
MST-8
CST-8
Asia/Kuala_Lumpur, Asia/Kuching
Asia/Harbin, Asia/Shanghai,
Asia/Chongqing, Asia/Urumqi,
Asia/Kashgar, Asia/Hong_Kong,
Asia/Macau, Asia/Macao, Hongkong, PRC,
ROC
Oceania
CST-9:30CDT
EST-10EDT
LHT-10:30LHDT
TST-10TDT
NZST-12NZDT
Australia/Adelaide, Australia/Broken_Hill,
Australia/South, Australia/Yancowinna
Australia/Brisbane, Australia/Lindeman,
Australia/Currie, Australia/Melbourne,
Australia/Sydney, Australia/ACT,
Australia/Canberra, Australia/NSW,
Australia/Queensland, Australia/Tasmania,
Australia/Victoria
Australia/Lord_Howe, Australia/LHI
Australia/Hobart
Antarctica/McMurdo, Pacific/Auckland,
Antarctica/South_Pole, NZ
User’s Manual 185
CIST-12:45CIDT
Africa
SAST-2
EST-2EDT
UAEST-4
IST-3IDT
JST-2JDT
SST-2SDT
Universal
UCT
UCT1
UCT2
UCT3
UCT4
UCT5
UCT6
Hardened Managed PoE Ethernet Switch
Pacific/Chatham, NZ-CHAT
Africa/Maseru, Africa/Johannesburg,
Africa/Mbabane
Africa/Cairo, Egypt
Asia/Dubai
Asia/Baghdad
Asia/Amman
Asia/Damascus
Africa/Ouagadougou, Africa/Abidjan,
Africa/Banjul, Africa/Accra, Africa/Conakry,
Africa/Bissau, Africa/Monrovia,
Africa/Bamako, Africa/Nouakchott,
Africa/Casablanca, Africa/El_Aaiun,
Atlantic/St_Helena, Africa/Sao_Tome,
Africa/Dakar, Africa/Freetown, Africa/Lome,
America/Danmarkshavn, Atlantic/Reykjavik,
Etc/GMT, Etc/UTC, Etc/UCT, GMT,
Etc/Universal, Etc/Zulu, Etc/Greenwich,
Etc/GMT-0, Etc/GMT+0, Etc/GMT0,
Africa/Timbuktu, GMT+0, GMT-0, GMT0,
Greenwich, Iceland, UCT, UTC, Universal,
Zulu
Atlantic/Cape_Verde, Etc/GMT+1
Atlantic/South_Georgia, Etc/GMT+2
Antarctica/Rothera, America/Belem,
America/Cayenne, America/Paramaribo,
Etc/GMT+3
America/Anguilla, America/Antigua,
America/Barbados, America/Dominica,
America/Grenada, America/Guadeloupe,
America/Martinique, America/Montserrat,
America/Puerto_Rico, America/St_Kitts,
America/St_Lucia, America/St_Vincent,
America/Tortola, America/St_Thomas,
America/Aruba, America/La_Paz,
America/Porto_Velho, America/Curacao,
America/Caracas, America/Guyana,
Etc/GMT+4, America/Virgin,
SystemV/AST4
America/Guayaquil, America/Eirunepe,
America/Lima, Etc/GMT+5
America/Belize, America/El_Salvador,
America/Tegucigalpa, Pacific/Galapagos,
Etc/GMT+6
Etc/GMT+7 UCT7
User’s Manual 186
Hardened Managed PoE Ethernet Switch
UCT8
UCT9
UCT10
UCT11
UCT-1
UCT-2
UCT-3
UCT-4
UCT-5
UCT-5:45
UCT-6
UCT-6:30
UCT-7
UCT-8
Etc/GMT+8
Pacific/Gambier, Etc/GMT+9,
SystemV/YST9
Pacific/Rarotonga, Pacific/Tahiti,
Pacific/Fakaofo, Pacific/Johnston,
Pacific/Honolulu, Etc/GMT+10, HST,
US/Hawaii, SystemV/HST10
Pacific/Niue, Pacific/Pago_Pago,
Pacific/Apia, Pacific/Midway, Etc/GMT+11,
Pacific/Samoa, US/Samoa
Africa/Algiers, Africa/Luanda,
Africa/Porto-Novo, Africa/Douala,
Africa/Bangui, Africa/Ndjamena,
Africa/Kinshasa, Africa/Brazzaville,
Africa/Malabo, Africa/Libreville,
Africa/Windhoek, Africa/Niamey,
Africa/Lagos, Etc/GMT-1
Africa/Gaborone, Africa/Bujumbura,
Africa/Lubumbashi, Africa/Tripoli,
Africa/Blantyre, Africa/Maputo, Africa/Kigali,
Africa/Lusaka, Africa/Harare, Etc/GMT-2,
Libya
Indian/Comoro, Africa/Djibouti,
Africa/Asmera, Africa/Addis_Ababa,
Africa/Nairobi, Indian/Antananarivo,
Indian/Mayotte, Africa/Mogadishu,
Africa/Khartoum, Africa/Dar_es_Salaam,
Africa/Kampala, Antarctica/Syowa,
Asia/Bahrain, Asia/Kuwait, Asia/Qatar,
Asia/Riyadh, Asia/Aden, Etc/GMT-3
Indian/Mauritius, Indian/Reunion,
Indian/Mahe, Asia/Muscat, Etc/GMT-4
Indian/Kerguelen, Indian/Maldives,
Asia/Karachi, Asia/Dushanbe,
Asia/Ashgabat, Asia/Samarkand,
Asia/Tashkent, Etc/GMT-5
Asia/Katmandu
Antarctica/Mawson, Antarctica/Vostok,
Asia/Dhaka, Asia/Thimphu, Indian/Chagos,
Asia/Colombo, Etc/GMT-6, Asia/Dacca,
Asia/Thimbu
Asia/Rangoon, Indian/Cocos
Antarctica/Davis, Asia/Phnom_Penh,
Asia/Jakarta, Asia/Pontianak,
Asia/Vientiane, Asia/Bangkok, Asia/Saigon,
Indian/Christmas, Etc/GMT-7
Antarctica/Casey, Asia/Brunei, Asia/Taipei,
Asia/Makassar, Asia/Manila,
User’s Manual 187
Hardened Managed PoE Ethernet Switch
UCT-9
UCT-9:30
UCT-10
UCT-11
UCT-11:30
UCT-12
UCT-13
JST
KST
UCT-3:30
UCT-4:30
IST-2IDT
CST6MEX
CST6
EET-2EETDST2
EET-2EETDST3
Asia/Singapore, Etc/GMT-8,
Asia/Ujung_Pandang, Singapore
Asia/Dili, Asia/Jayapura, Pacific/Palau,
Etc/GMT-9
Australia/Darwin, Australia/North
Antarctica/DumontDUrville, Pacific/Guam,
Pacific/Saipan, Pacific/Truk,
Pacific/Noumea, Pacific/Port_Moresby,
Etc/GMT-10, Pacific/Yap
Pacific/Ponape, Pacific/Kosrae,
Pacific/Guadalcanal, Etc/GMT-11
Pacific/Norfolk
Pacific/Fiji, Pacific/Tarawa,
Pacific/Enderbury, Pacific/Majuro,
Pacific/Kwajalein, Pacific/Nauru,
Pacific/Tongatapu, Pacific/Funafuti,
Pacific/Wake, Pacific/Efate, Pacific/Wallis,
Etc/GMT-12, Kwajalein
Etc/GMT-13
Asia/Tokyo, Japan
Asia/Seoul, Asia/Pyongyang, ROK
Asia/Tehran, Iran
Asia/Kabul
Asia/Jerusalem, Asia/Gaza, Asia/Tel_Aviv,
Israel
America/Cancun, America/Merida,
America/Monterrey, America/Mexico_City,
America/Lima, Mexico/General
America/Regina, America/Swift_Current,
Canada/East-Saskatchewan,
Canada/Saskatchewan, SystemV/CST6
Europe/Bucharest
Europe/Tallinn, Europe/Helsinki,
Europe/Riga, Europe/Mariehamn
Europe/Istanbul
Pacific/Kiritimati, Etc/GMT-14
Pacific/Marquesas
Etc/GMT+12
EET-2EETDST2W2K
UCT-14
UCT9:30
UCT12
North America (Canada)
PST8PDT_CA
MST7MDT_CA
CST6CDT_CA
America/Vancouver,
America/Dawson_Creek,
America/Whitehorse, America/Dawson,
Canada/Pacific
America/Edmonton, America/Yellowknife,
America/Inuvik, Canada/Mountain
America/Rainy_River, America/Winnipeg,
America/Rankin_Inlet, Canada/Central
User’s Manual 188
Hardened Managed PoE Ethernet Switch
EST5EDT_CA
AST4ADT_CA
America/Montreal, America/Toronto,
America/Thunder_Bay, America/Nipigon,
America/Iqaluit, Canada/Eastern
America/Goose_Bay, America/Halifax,
America/Glace_Bay, Canada/Atlantic
North America (Cuba)
EST5EDT_CU
North America (Haiti)
EST5EDT_HT
America/Havana, Cuba
America/Nassau, America/Santo_Domingo,
America/Port-au-Prince, America/Bogota
North America (Mexico)
PST8PDT_MX
MST7MDT_MX
CST6CDT_MX America/Guatemala
North America (Turks and Caicos)
EST5EDT_TC
Additions Since 10g RTM
America/Grand_Turk
EST5EDT_INDIANA
America/Tijuana, America/Ensenada,
Mexico/BajaNorte
America/Chihuahua, America/Hermosillo,
America/Mazatlan, Mexico/BajaSur
UCT-8_WA
America/Indiana/Indianapolis,
America/Indiana/Marengo,
America/Indiana/Vevay,
America/Fort_Wayne,
America/Indianapolis,
America/Indiana/Knox, America/Knox_IN,
US/Indiana-Starke, US/East-Indiana
Australia/Perth, Australia/West
User’s Manual 189
Hardened Managed PoE Ethernet Switch
Contact Information
SIGNAMAX
CONNECTIVITY SYSTEMS
An AESP Company
16295 N.W. 13h Avenue
Miami, Florida 33169, U.S.A.
Phone: 305-944-7710 Fax: 305-949-4483
Sales: 800-446-2377 Tech. Support: 800-446-2377, ext. 201
Http://www.signamax.com
E-mail:
[email protected]
User’s Manual 190
advertisement
Key Features
- Meets NEMA TS1/TS2 Environmental Requirements
- Supports IEEE802.3af Power over Ethernet (PoE) and IEEE802.3at PoE+ Power Sourcing Equipment (PSE)
- Supports 8192 MAC addresses
- Supports Command Line Interface in RS-232 console
- RS-232 console, Telnet, SNMP v1 & v2c & v3, RMON, Web Browser, and TFTP management
- Web-based browser interface
- Administration console via RS-232 serial port (CLI)
Frequently Answers and Questions
What environmental requirements does this switch meet?
What are the management options available for this switch?
Does this switch support Power over Ethernet (PoE)?
Related manuals
advertisement
Table of contents
- 2 Quick Start Guide
- 2 Physical Description
- 2 The Port Status LEDs and Power Inputs
- 4 Functional Description
- 5 Console Configuration
- 7 Web Configuration
- 10 Preface
- 11 Table of Contents
- 13 Product Overview
- 13 Hardened Managed Ethernet Switch
- 13 Package Contents
- 14 Product Highlights
- 14 Basic Features
- 14 Management Support
- 14 VLAN
- 15 TRUNKING
- 15 PORT-SECURITY
- 15 PORT-MIRRORING
- 15 QoS (IEEE802.1p Quality of Service)
- 15 INTERNETWORKING PROTOCOLS
- 15 NETWORK MANAGEMENT METHODS
- 16 Front Panel Display
- 16 This LED comes on when the switch is properly connected to power and turned on.
- 16 The LEDs are located on the front panel, displaying status for each respective port. Please refer to the following table for more details.
- 16 Physical Ports
- 17 Connectivity
- 17 Mode Selection
- 18 Switch Management
- 18 Web-based browser interface
- 18 Administration console via RS-232 serial port (CLI)
- 18 External SNMP-based network management application
- 19 Installation
- 19 Selecting a Site for the Switch
- 19 Connecting to Power
- 19 DC Terminal Block Power Input
- 20 Connecting to Your Network
- 20 Cable Type & Length
- 21 Cabling
- 22 Switch Management
- 22 Management Access Overview
- 23 Administration Console (CLI)
- 23 Direct Access
- 23 [Default parameters]
- 24 Modem Access
- 24 Web Management
- 24 SNMP-Based Network Management
- 25 Protocols
- 25 Virtual terminal protocols, such as Telnet
- 25 A virtual terminal protocol is a software program, such as Telnet, that allows you to establish a management session from a Macintosh, a PC, or a UNIX workstation. Because Telnet runs over TCP/IP, you must have at least one IP address configured on th...
- 25 Simple Network Management Protocol (SNMP)
- 25 SNMP is the standard management protocol for multivendor IP networks. SNMP supports transaction-based queries that allow the protocol to format messages and to transmit information between reporting devices and data-collection programs. SNMP runs on t...
- 25 Management Architecture
- 26 Web-Based Browser Management
- 27 SNMP & RMON Management
- 27 Overview
- 27 - The RMON probe is an intelligent device or software agent that continually collects statistics about a LAN segment or VLAN. The RMON probe transfers the collected data to a management workstation on request or when a pre-defined threshold is reached.
- 27 - The management workstation collects the statistics that the RMON probe gathers. The workstation can reside on the same network as the probe, or it can have an in-band or out-of-band connection to the probe.
- 28 SNMP Agent and MIB-2 (RFC 1213)
- 28 - Retrieving MIB counters from various layers of software modules according to the SNMP GET/GET NEXT frame messages.
- 28 - Setting MIB variables according to the SNMP SET frame message.
- 28 - Generating an SNMP TRAP frame message to the Network Management Station if the threshold of a certain MIB counter is reached or if other trap conditions (such as the following) are met:
- 28 Warm start
- 28 Cold start
- 28 Link up
- 28 Link down
- 28 Authentication failure
- 28 Rising alarm
- 28 Falling alarm
- 28 Topology Alarm
- 28 RMON MIB (RFC 2819) and Bridge MIB (RFC 1493)
- 29 RMON Groups Supported
- 29 - RMON Statistics Group – maintains utilization and error statistics for the switch port being monitored.
- 29 - RMON History Group – gathers and stores periodic statistical samples from the previous Statistics Group.
- 29 - RMON Alarm Group – allows a network administrator to define alarm thresholds for any MIB variable. An alarm can be associated with Low Threshold, High Threshold, or both. A trigger can trigger an alarm when the value of a specific MIB variable exceeds a ˝
- 29 - RMON Event Group – allows a network administrator to define actions based on alarms. SNMP Traps are generated when RMON Alarms are triggered. The action taken in the Network Management Station depends on the specific network management application.
- 29 Bridge Groups Supported
- 29 - The dot1dBase Group – a mandatory group that contains the objects applicable to all types of bridges.
- 29 - The dot1dStp Group – contains objects that denote the bridge’s state with respect to the Spanning Tree Protocol. If a node does not implement the Spanning Tree Protocol, this group will not be implemented. This group is applicable to any transparent only˝
- 29 - The dot1dTp Group – contains objects that describe the entity’s transparent bridging status. This group is applicable to transparent operation only and SRT bridges.
- 29 - The dot1dStatic Group – contains objects that describe the entity’s destination-address filtering status. This group is applicable to any type of bridge which performs destination-address filtering.
- 30 Web-Based Browser Management
- 30 Logging on to the switch
- 30 Switch IP Address
- 31 Login
- 31 Enter the factory default login ID: root.
- 31 Password
- 31 Enter the factory default password (no password).
- 32 Understanding the Browser Interface
- 32 System
- 32 System Information, System Name/Password, IP Address, ARP Table, Route Table, Save Configuration, Firmware Upgrade, Reboot, Logout
- 32 port
- 32 Configuration, Port Status, Rate Control, RMON Statistics, Per Port Vlan Activities
- 32 switching
- 32 Bridging, Static MAC Entry, Port Mirroring, PoE, PoE Scheduling
- 32 Trunking
- 32 Port Trunking
- 33 stp / Ring
- 33 VLAN
- 33 VLAN Mode Setting, 802.1Q VLAN Setting, 802.1Q Port Setting, Port Based VLAN
- 33 qos
- 33 Global Configuration, 802.1p Priority, DSCP
- 33 SNMP
- 33 802.1x
- 33 OTHER PROTOCOLS
- 34 System
- 34 System Information
- 35 System Name/Password
- 36 IP Address
- 37 ARP Table
- 38 Route Table
- 39 Save Configuration
- 40 Firmware Upgrade
- 45 Reboot
- 46 Logout
- 47 Port
- 47 Configuration
- 49 Port Status
- 50 Rate Control
- 51 RMON Statistics
- 52 Per Port Vlan Activities
- 53 Switching
- 53 Bridging
- 54 Static MAC Entry
- 55 Port Mirroring
- 56 PoE
- 57 Flexible 802.3af High Power PoE Operation: Compatible with the 802.3at Standard
- 59 PoE Scheduling
- 60 Trunking
- 60 Port Trunking
- 61 STP / Ring
- 61 Global Configuration
- 62 RSTP Port Setting
- 64 MSTP Properties
- 66 MSTP Instance Setting
- 68 MSTP Port Setting
- 69 Recover-Ring(tm) Capability
- 71 VLAN
- 71 VLAN Mode Setting
- 73 802.1Q VLAN Setting
- 74 802.1Q Port Setting
- 75 Port Based VLAN
- 77 QoS
- 77 Global Configuration
- 78 802.1p Priority
- 79 DSCP
- 80 SNMP
- 80 SNMP General Setting
- 81 SNMP v1/v2c
- 83 SNMP v3
- 85 802.1x
- 85 Radius Configuration
- 88 Port Authentication
- 89 Other Protocols
- 89 GVRP
- 91 IGMP Snooping
- 93 NTP
- 95 Command Line Console Management
- 95 Administration Console
- 96 Exec Mode (View Mode)
- 100 Privileged Exec Mode (Enable Mode)
- 105 Configure Mode (Configure Terminal Mode)
- 109 System
- 109 System Information, System Name/Password, IP Address, ARP Table, Route Table, Save Configuration, Firmware Upgrade, Reboot, Logout
- 109 System Name/Password
- 110 IP Address
- 111 ARP Table
- 112 Route Table
- 112 Save Configuration
- 115 Firmware Upgrade
- 117 Reboot
- 117 Logout
- 118 Port
- 118 Configuration, Port Status, Rate Control, RMON Statistics, Per Port Vlan Activities
- 118 Configuration
- 120 Port Status
- 121 Rate Control
- 121 RMON Statistics
- 122 Per Port Vlan Activities
- 123 Switching
- 123 Bridging, Static MAC Entry, Port Mirroring, PoE, PoE Scheduling
- 123 Bridging
- 125 Static MAC Entry
- 127 Port Mirroring
- 127 PoE
- 130 PoE Scheduling
- 132 Trunking
- 132 Port Trunking
- 132 Port Trunking
- 133 STP / Ring
- 133 Global Configuration, RSTP Port Setting, MSTP Properties, MSTP Instance Setting, MSTP Port Setting, Recover-Ring(tm) Capability
- 133 Global Configuration
- 137 RSTP Port Setting
- 140 MSTP Properties
- 142 MSTP Instance Setting
- 143 MSTP Port Setting
- 145 Recover-Ring(tm) Capability
- 147 VLAN
- 147 VLAN Mode Setting, 802.1Q VLAN Setting, 802.1Q Port Setting, Port Based VLAN
- 147 802.1Q VLAN Setting
- 148 802.1Q Port Setting
- 152 Port Based VLAN
- 153 QoS
- 153 Global Configuration
- 155 802.1p Priority
- 155 DSCP
- 156 SNMP
- 156 SNMP General Setting
- 161 SNMP v1/v2c
- 162 SNMP v3
- 165 802.1x
- 165 Radius Configuration
- 167 Port Authentication
- 170 Other Protocols
- 170 GVRP
- 172 IGMP Snooping
- 177 NTP
- 182 Specifications
- 182 LED Indicators
- 182 Operating
- 182 Temperature
- 183 Appendix A
- 184 Appendix B
- 191 Contact Information
- 191 UHttp://www.signamax.com