01 CAUTION
• Always use set voltage. (DC 12V MAX 6A)
• When using a DC Adapter other than the one
supplied by the manufacturer, please be advised
that the adapter with DC 12V/3A ~ 6A can be
compatible with the monitor.
• All operating instructions must be read and
understood before the product is operated.
• These safety and operating instructions must be
kept in safe place for future reference.
• All warnings on the product and in the instructions
must be observed closely.
• All operating instructions must be followed.
• Do not use attachments not recommended by the
manufacturer. Use of inadequate attachments
can result in accidents.
• This product must be operated on a power
source specified on the specification label.
• If you are not sure of the type of power supply
used in your home, consult your dealer or local
power company. For units designed to operate
on batteries or another power source, refer to the
operating instructions.
• The power cords must be routed properly to
prevent people from stepping on them or objects
from resting on them. Check the cords at the
plugs and product.
• In case of using other 12V DC adapters instead of
the standard adapter provided by the manufacturer,
please check the proper load capacity (or current
capacity) and use an adapter with stable voltage.
• Do not overload DC outlets or extension cords.
Overloading can cause or electric shock.
• Never insert an object into the product through
vents or openings. High voltage in the product,
and inserting an object can cause electric shock
and/or short internal parts. For the same reason,
do not spill water or liquid on the product.
• Do not attempt to service the product yourself.
Removing covers can expose you to high voltage
and other dangerous conditions. Request a
qualified service person to perform servicing.
• If any of the following conditions occurs, unplug
the power cord from the DC outlet, and request a
qualified service person to perform repairs.
a. When the power cord or plug is damaged.
b. When a liquid was spilled on the product or
when objects have fallen into the product.
c. When the product has been exposed to rain or
water.
d. When the product does not operate properly as
described in the operating instructions. Do not
touch the controls other than those described
in the operating instructions.
Improper adjustment of controls not described
in the instructions can cause damage, which often
requires extensive adjustment work by a
qualified technician.
e. When the product has been dropped or
damaged.
f. When the product displays an abnormal
condition.
Any noticeable abnormality in the product
indicates that the product needs servicing.
• In case the product needs replacement parts,
make sure that the service person uses replacement
parts specified by the manufacturer, or those with
the same characteristics and performance as the
original parts. Use of unauthorized parts can
result in fire, electric shock and/or other danger.
• Upon completion of service or repair work, request
the service technician to perform safety checks to
ensure that the product is in proper operating
condition.
• When mounting the product on a wall or ceiling,
be sure to install the product according to the
method recommended by the manufacturer.
• Unplug the power cord from the DC outlet before
cleaning the product. Use a damp cloth to clean
the product. Do not use liquid cleaners or aerosol
cleaners.
• Unplug the power cord from the AC outlet if you
do not use the product for considerably long time.
Field Production Monitor
01 CAUTION
• Do not use the product near water, such as bathtub,
washbasin, kitchen sink and laundry tub,
swimming pool and in a wet basement.
• Keep the product away from direct rays of the
Sun-light.
• Do not place the product on an unstable cart,
stand, tripod or table. Placing the product on an
unstable base can cause the product to fall,
resulting in serious personal injuries as well as
damage to the product. Use only a cart, stand,
tripod, bracket or table recommended by the
manufacturer or sold with the product. When
mounting the product on a wall, be sure to follow
the manufacturer’s instruction. Use only the
mounting hardware recommended by the
manufacturer.
• When relocating the product placed on a cart, it
must be moved with the utmost care.
• The power cord plug shall be connected to a
MAINS socket outlet with a protective earthing
connection.
• Infrared devices can cause noise or malfunction
under condition as below.
– parts of the body come into contact with the
infrared transmiter or acoustic device.
– Obstacles can cause electrical changes if there is
a partition in the middle or in the wall.
– Exposure to radio interference from medical
equipment, microwave ovens, wireless LAN
devices, etc. with the same frequency band.
• Unplug the power cord from the AC outlet when
happening any problem in the product.
• Sudden stops, excessive force and uneven floor
surface can cause the product to fall from the cart.
• The vents and other openings in the cabinet are
designed for ventilation. Do not cover or block
these vents and openings since insufficient
ventilation can cause overheating and/or shorten
the life of the product. Do not place the product
on a bed, sofa, rug or other similar surface, since
they can block ventilation openings. This product
is not designed for built-in installation; do not
place the product in an enclosed place such as a
bookcase or rack, unless proper ventilation is
provided or the manufacturer’s instructions are
followed.
• In case of installation the product on the rack, the
inside of the product would be overheated due to
heat from other devices near by and the decrease
of air circulation, which could damage to the
monitor. To prevent the damage, please have
enough space for the monitors and use fan to
avoid heat and maintain the operating temperature.
(Refer to the specication of the product).
• The LCD panel used in this product is made of
glass. Therefore, it can break when the product is
dropped or applied with impact. Be careful not to
be injured by broken glass pieces in case the LCD
panel breaks.
• Keep the product away from heat sources such as
radiators, heaters, stoves and other heat generating
products (including amplifiers).
5
Field Production Monitor
02 MAIN FEATURES
R-Series Monitors contain the following features :
• Compatible with various SDI signals formats
(SD/HD/3G)
- This product is compatible with various SDI
signals - 480i, 576i, 720p, 1080i, 1080p, 1080psf
• HDMI(with HDCP) Signal
- This product is compatible with various HDMI
signals.
• HDMI To SDI / SDI To HDMI Conversion Output
- This product features an HDMI To SDI conversion
output so that video source from HDMI In
terminal
can be output through SDI Out terminal.
- The SDI To HDMI conversion output is also
supported. The video source from SDI In
terminal can be output through HDMI Out
terminal.
• All-in-one type system
- Slim and all-in-one type monitor that requires
no additional accessories, for optimized space
utilization.
• Waveform/Vectorscope/Audio Level Meter
Function
- Waveform & Vector Scope
- Embedded Audio Level Meter
• Audio Out
- Stereo Audio Out through phone Jack.
• Knob Control
- Easy to adjust user configuration using the
control knob on the top of the monitor.
• BLUE ONLY / MONO / Focus Assist/ H/V Delay
Function
• Range Error/Luma(Y’) Zone Check(Color/Zebra
Type) Function
• Internal Pattern Generator (0~100% Gray/
ColorBar+Pluge)
• Various Markers & Safety Areas
- Center Marker, Safety Area Marker, Marker Mat,
Marker Size, Fit Marker, Thickness Adjustment
function
• 1:1 Scan/Zoom Function
- Used to display the original image resolution
without scaling to match a certain resolution or
an aspect ratio.
- Select ‘Pixel to pixel’ to display unscaled images,
and select ‘Zoom’ to enlarge the original image.
- Zoom Scroll Function (Left/Right, Top/Bottom)
• RS422 / D-UMD feature support
- This product supports TSL3.1 protocol using the
RS-422 communication.
• Power
- Basically, the product is powered by a normal DC
source.
- The product can be battery-powered.
* DC 12 (Typical)
• Additional features
- OSD user interface and Rack-Mountable Design.
6
03 CONTROLS & FUNCTIONS
R-5T : FRONT
TALLY POWER
MENU
UP
DOWN
ENTER
USB
Field Production Monitor
• [TALLY]
- Tally lamp that can be toggled in green or red
using the REMOTE(RS-422) port or TVLogic’s
control program(Observer).
• [POWER]
- Used to turn the power on and off.
• [MENU]
- Used to activate the OSD menu.
- When the OSD menu is activated, press the
MENU button to exit from the menu.
- Press the MENU button more than 2 seconds,
input select menu will activated.(SDI, HDMI)
• [UP]
- Used to move within the menu when the OSD
menu is activated and is also used to increase
the value of selected feature.
• [DOWN]
- Used to move within the menu when the OSD
menu is activated and is also used to decrease
the value of selected feature.
• [ENTER]
- Used to select the feature of main menu and
the sub menus.
- When the OSD menu is deactivated, press
the ENTER button longer to activate the
menus in order of : [BRIGHTNESS]-
[CONTRAST]-[CHROMA]-[SHAPNESS] -
[PEAKING BOOST] After the function is activated,
press the [DOWN]/[UP] button to adjust the
values.
• [USB] (Micro B USB)
- Use the Micro B Type USB. The OTG gender is
required when using a USB Memory Stick.
- Used to upgrade the firmware using a USB
Memory Stick or calibrate the monitor’s color
temperature using the TVLogic’s color
calibration tool.
7
Field Production Monitor
03 CONTROLS & FUNCTIONS
R-5T : REAR
12G/6G/3G
SDI IN
12G/6G/3G
SDI OUT
3G-SDI
IN
3G-SDI
OUT HDMI
RS-422 IN RS-422 OUT REMOTE DC IN
• 12G/6G/3G [SDI IN/OUT] (BNC)
- Signal input/output terminals for 12G/6G/3G/
HD/SD SDI signal.
- Outputs the SDI signal input from the [SDI IN]
terminal to [SDI OUT] terminal.
• 3G [SDI IN/OUT] (BNC)
- Signal input/output terminals for 3G/HD/SD
SDI signal.
- Outputs the SDI signal input from the [SDI IN]
terminal to [SDI OUT] terminal.
• [HDMI IN] (HDMI)
- Signal input terminals for HDMI signal.
• [REMOTE] (RS-422)
- Provides connection to control equipment
(parallel switch) for external monitor control.
- Features of the each pin can be changed in the
[MARKER] section of the OSD menu.
• [RS-422 IN/OUT] (RS-422)
- Used to control the Dynamic UMD function
with the TSL3.1 protocol.
• DC IN
-12V DC
<WARNING!!>
When using the product make sure to ground, whenever possible, before connecting the input signal cable in order to prevent any possible damage to the product or connected devices. The damage may include signal noise, malfunction of main board or display panel. And the connected devices such as camera or video source player may also be influenced through signal cable.
Please check if the AC power source and the power extender or power distributor is grounded.
8
Field Production Monitor
03 CONTROLS & FUNCTIONS
R-7D : FRONT
SDI
HDMI
POWER
TALLY
F1
F2
MENU/EXIT
KNOB
AUDIO OUT
USB
• [TALLY]
- Tally lamp that can be toggled in green or red
using the REMOTE(RS-422) port or TVLogic’s
control program(Observer).
• [SDI]
- Select the SDI A / B input signal.
• [HDMI]
- Select the HDMI input signal.
• [F1/F2]
- Press the button for less than 2 seconds to
activate the function.
- Press the button for more than 2 seconds to
activate Function Select menu.
• [POWER]
- Used to turn the power on and off.
• [MENU/EXIT] Button
- Used to activate the OSD menu.
- When the OSD menu is activated, press this
button to exit from the menu.
- Press the button for more than 2 seconds to
activate Input Select menu. (SDI, HDMI)
- Use the [ENCODER] Knob to change the Input
Signal.
• [UP/DOWN/ENTER] Knob
- Used to move within the menu when OSD
menu is activated, and is also used to decrease
or increase the value of the selected feature.
- Press the knob to select the main menu and
the sub menus.
- Press the button for more than 2 seconds to
activate the HOT Key menu. (BRIGHT /
CONTRAST / CHROMA / SHAPRNESS / PEAKING
BOOST)
- Press the button for less than 2 seconds to
activate the PRESET function.
• [USB] (USB-A)
- Use the Micro B Type USB. The OTG gender
is required when using a USB Memory
Stick.
- Used to upgrade the firmware using a USB
Memory Stick or calibrate the monitor’s
color temperature using the TVLogic’s color
calibration tool.
• [AUDIO OUT] (Phonejack)
- Used for Stereo Audio Output through Phone
Jack. (video signals with embedded audio only)
9
Field Production Monitor
03 CONTROLS & FUNCTIONS
R-7D : REAR
HDMI
12G/6G/3G
IN OUT
3G
IN OUT DC IN
RS-422 IN
RS-422 OUT
REMOTE
• 12G/6G/3G [SDI IN/OUT] (BNC)
- Signal input/output terminals for 12G/6G/3G/
HD/SD SDI signal.
- Outputs the SDI signal input from the [SDI IN]
terminal to [SDI OUT] terminal.
• 3G [SDI IN/OUT] (BNC)
- Signal input/output terminals for 3G/HD/SD SDI
signal.
- Outputs the SDI signal input from the [SDI IN]
terminal to [SDI OUT] terminal.
• [HDMI IN] (HDMI)
- Signal input terminals for HDMI signal.
• [REMOTE] (RS-422)
- Provides connection to control equipment
(parallel switch) for external monitor control.
- Features of the each pin can be changed in the
[MARKER] section of the OSD menu.
• [RS-422 IN/OUT] (RS-422)
- Used to control the Dynamic UMD function with
the TSL3.1 protocol.
• DC IN
-12V DC
<WARNING!!>
When using the product make sure to ground, whenever possible, before connecting the input signal cable in order to prevent any possible damage to the product or connected devices. The damage may include signal noise, malfunction of main board or display panel. And the connected devices such as camera or video source player may also be influenced through signal cable.
Please check if the AC power source and the power extender or power distributor is grounded.
10
04 MENU TREE & ADJUSTMENT
Field Production Monitor
[1] MENU TREE
• OSD(On-Screen Display) Menu helps to use
varous different functions.
• This Picture is the menu structure for R-Series
PICTURE 같이
BRIGHTNESS
CONTRAST
CHROMA
SHARPNESS
PEAKING BOOST
KEY LOCK
3D LUT LOAD
3DLUT SYNC
3DLUT IMPORT 1
3DLUT IMPORT 2
3DLUT IMPORT 3
R-7D
+0
+0
+0
+0
+0
[3] MENU CONTROL SEQUENCE
• Menu control sequence follows the order below.
1 .
Press MENU button to activate the OSD menu.
2. Move to a desired menu using the Knob.
3. Press the Knob to select a menu and move to
select a sub-menu by scrolling the Knob.
4. Press the Knob to select the desired sub menu.
(The selected sub-menu will be highlighted)
5. Press the ENTER button or the MENU button to
save the new value after adjusting the value by
scrolling the Knob.
6. Press MENU button to return to previous menu
and if there is no previous menu, the OSD menu
will be removed from the screen.
[2] MENU CONTROL
• User may control various functions using the
MENU button and the Knob on the top of the
monitor.
* In the case of the R-7D, use the KNOB instead of
the UP/DOWN/ENTER button.
11
Field Production Monitor
05 MENU OPERATIONS
[1] PICTURE
PICTURE 같이
BRIGHTNESS
CONTRAST
CHROMA
SHARPNESS
PEAKING BOOST
KEY LOCK
3D LUT LOAD
3DLUT SYNC
3DLUT IMPORT 1
3DLUT IMPORT 2
3DLUT IMPORT 3
R-7D
+0
+0
+0
+0
+0
• BRIGHT
- Used to set the brightness(=offset) level from
-100 to 100.
• CONTRAST
- Used to set the contrast(gain) level from -100 to
100.
• CHROMA
- Used to set the saturation level from -50 to 50.
• SHARPNESS
- Used to set the Sharpness level from 0 to 24.
• PEAKING BOOST
- Used to set the Peaking Boost level from 0 to 24.
• KNOB LOCK
- Locks the Knob control.
• 3DLUT LOAD
- Used to apply the internally stored 3DLUT.
- Maximum 3 x 3DLUT files can be stored.
- The file name can be set up to 20 characters
including the extension.
• 3DLUT SYNC
- Used to load a list of available 3DLUT files
currently stored in the FLASH MEMORY.
- Available 3DLUT formats are Cube, GV Lut,
Quantel, Davinci and Assimilate Scratch.
- Available sizes of the 3DLUT are 17 or 33.
• 3DLUT IMPORT 1/2/3
- Used to save the 3DLUT stored in the external
memory to the internal memory 1/2/3 area.
- Once saved, the 3DLUT can be maintained even
when the power is turned ON/OFF.
- The file name can be set up to 20 characters
including the extension.
12 12
Field Production Monitor
05 MENU OPERATIONS
[2] COLOR
COLOR 같이
STANDARD
VIDEO RANGE
PEAK LUMINANCE
BLACK LEVEL
COLOR GAMUT
COLOR TEMP
EOTF
LOCAL DIMMING
EETF
HLG SG
SG
CAM LUT
UHD
LIMITED109
100
0.001
BT.2020
6500K
2.4
OFF
OFF
OFF
OFF
OFF
R-7D
PAGE(1/2)
• STANDARD
- Used to select the color and dynamic rage of the
screen.
- Available options are HD, UHD, DCI-P3, PQ, HLG,
SLog3 and User1/2/3.
# Activates only in the User1/2/3 mode.
• VIDEO RANGE
- Used to select the range of digital video signal.
* FULL : Input signal 0~255 (8bit), 0~1023
(10bit) (When connecting the PC)
* LIMITED109 : Input signal Y‘: 16~235, CbCr:
16~240 (8bit)/ Y‘: 64~940, CbCr: 64-960 (10bit)
• PEAK LUMINANCE
- Used to select the Peak Luminance of the
monitor.
- Available options are 100, 200, 300, 400, 500,
600, 700, 800, 900, 1000, 2000, 4000 and 10000.
- Activates only in the User1/2/3 mode.
• BLACK LEVEL
- The minimum black level of the video signal
can be set differently depending on the
performance of the monitor or the lighting
environment. For example, the lowest luminance
that the R-Series can display is 0.002, but it is
necessary to adjust the offset level to about
0.2nit when using under bright light.
- At this time, when the black level is set to 0.2,
dark gradations below 0.2 nit are expressed
without crushing.
- Activates only in the User1/2/3 mode.
• COLOR GAMUT
- Used to select the standard color gamut.
- Available options are BT.709, DCI-P3, BT.2020
and Native.
# The submenus may be activated in the User1/2/3
mode only.
• COLOR TEMP (Color Temperature)
- Controls the color temperature.
- Available options are 6500K, 9300K and User.
# The submenus may be activated in the User1/2/3
mode only.
• EOTF (Electro-Optical Transfer Function)
- Electrophotic conversion Functions(ex: Gamma
or HDR curve).
- Available modes are 2.2, 2.4, 2.6, PQ, HLG and
SLOG3.
# The submenus may be activated in the User1/2/3
mode only.
• LOCAL DIMMING
- Used to set the Local Dimming Backlight mode.
- This mode is supported by the local dimming
backlight model (LUM-310R) and does not
support R-Series.
13
Field Production Monitor
05 MENU OPERATIONS
[2] COLOR
COLOR 같이
STANDARD
VIDEO RANGE
PEAK LUMINANCE
BLACK LEVEL
COLOR GAMUT
COLOR TEMP
EOTF
LOCAL DIMMING
EETF
HLG SG
SG
CAM LUT
OFF
OFF
OFF
OFF
OFF
UHD
LIMITED109
100
0.001
BT.2020
6500K
2.4
R-7D
• SG (System Gamma)
- The System Gamma of HLG is automatically
calculated and displayed according to the set
peak luminance.
- Activates only when the EOTF is set to HLG and
the HLG SG is Auto.
• CAM LUT (Camera LUT)
- Used to change the Camera LUT.
- Available LUTs are OFF, LOG-C, C-LOG, S-LOG
1,2,3 and RED Gamma 3,4.
PAGE(1/2)
• EETF (Electrical-Electrical Fransfer Function)
- Used to display the HDR image(without clipping)
within the actual luminance range (black level
and peak luminance) that the monitor can
express. In the Auto mode, the HDR image is
converted within the range of set peak luminance
and black level. In the OFF mode, the video
signal outside of the set range is clipped.
- Available modes are OFF and AUTO.
- Available only when the EOTF is set to PQ or
SLOG3.
# The submenus may be activated in the User1/2/3
mode only.
• HLG SG (HLG System Gamma)
- Used to set the System Gamma of HLG mode.
- In the Auto mode, the value of the System
Gamma changes automatically according to the
previously set peak luminance. When it is OFF,
the value is set to default value of 1.2.
- Activates only when the EOTF is set to HLG.
# The submenus may be activated in the User1/2/3
mode only.
14
Field Production Monitor
05 MENU OPERATIONS
[2] COLOR
COLOR 같이
COLOR TEMP
GAIN RED
GAIN GREEN
GAIN BLUE
BIAS RED
BIAS GREEN
BIAS BLUE
COLOR COPY
COLOR SPACE
6500K
6500K
BT.709
R-7D
+0
+0
+0
+0
+0
+0
• COLOR SPACE
- Used to select the standard color space.
- Available options are BT.709, DCI-P3, BT.2020 and
Native.
PAGE(2/2)
• TEMP COLOR (Color Temperature)
- Controls the color temperature and allows
instant access to preset the color temperature
settings.
- Available color temperatures are 6500K, 9300K
and User1/2/3.
# In User 1/2/3 modes, user can define custom
RGB GAIN, BIAS (=Offset) and Color Copy values.
• GAIN RED / GREEN / BLUE
- Used to set Red/Green/Blue Gain(or Picture,
Contrast) level from -256 to 255.
# Only available in User 1/2/3 mode.
• BIAS RED / GREEN / BLUE
- Used to set Red/Green/Blue Bias(or Offset,
mainly affects on Black level) from -100 to 100.
# Only available in User 1/2/3 mode.
• COLOR COPY
- Used to copy the R/G/B Gain value of pre-stored
color temperature settings.
- In User mode, find and select the color
temperature and press the Knob to copy and
apply the Gain value to GAIN RED, GAIN GREEN,
GAIN BLUE.
# Only available in User 1/2/3 mode.
15
Field Production Monitor
05 MENU OPERATIONS
[3] MARKER
MARKER 같이
ENABLE
MARKER
CENTER MARKER
SAFETY AREA
FIT MARKER
MARKER MAT
MARKER COLOR
THICKNESS
USER MARKER H1
USER MARKER H2
USER MARKER V1
USER MARKER V2
GRID ENABLE
GRID TYPE
GRID THICKNESS
ON
OFF
OFF
OFF
OFF
OFF
WHITE
2
OFF
OFF
2
R-7D
+ 0
+1920
+ 0
+1080
• ENABLE
- Used to activate the Marker function.
• MARKER
- Available Marker types are OFF, 16:9, 4:3, 4:3 ON
AIR, 15:9, 14:9, 13:9, 1.85:1, 2.35:1, 1.85:1& 4:3 and
USER.
• CENTER MARKER
- Displays the Center Marker on the screen.
• SAFETY AREA
- Used to select to display and controls the size
and availability of the Safety Area.
- Available sizes are 80%, 85%, 88%, 90%, 93%,
100%, EBU ACTION 16:9, EBU GRAPHIC 16:9, EBU
ACTION 14:9, EBU GRAPHIC 14:9, EBU ACTION 4:3
and EBU GRAPHIC 4:3.
• FIT MARKER
- Used to activate or inactivate the Fit Marker
function.
- When the Marker type is selected in the Marker
menu, a border line of the Safety Area will be
displayed inside the Marker. Images below
show the difference between Fit Marker ON and
OFF.
MARKER : 4:3
SAFETY AREA : 90%
FIT MARKER : OFF
MARKER : 4:3
SAFETY AREA : 90%
FIT MARKER : ON
• MARKER MAT
- Used to set the darkness level outside of the
MARKER area from OFF(transparent) to 7(Black).
- The bigger the value, the darker the color.
• MARKER COLOR
- Used to set the color of the MARKER lines.
- Available colors are white, gray, black, red, green
and blue.
• THICKNESS
- Used to set the thickness of the MARKER lines.
- Thickness level is from 1 to 7 by the pixel unit.
• USER MARKER H1
- Used to set the position of the first horizontal
marker line.
- Displayed when the MARKER menu is set to
USER.
• USER MARKER H2
- Used to set the position of the second horizontal
marker line.
- Displayed when the MARKER menu is set to
USER.
• USER MARKER V1
- Used to set the position of the first vertical
marker line.
- Displayed when the MARKER menu is set to
USER.
• USER MARKER V2
- Used to set the position of the second vertical
marker line.
- Displayed when the MARKER menu is set to
USER.
16
Field Production Monitor
05 MENU OPERATIONS
[3] MARKER
MARKER 같이
ENABLE
MARKER
CENTER MARKER
SAFETY AREA
FIT MARKER
MARKER MAT
MARKER COLOR
THICKNESS
USER MARKER H1
USER MARKER H2
USER MARKER V1
USER MARKER V2
GRID ENABLE
GRID TYPE
GRID THICKNESS
ON
OFF
OFF
OFF
OFF
OFF
WHITE
2
OFF
OFF
2
• USER MARKER H1
- Used to set the position of the first horizontal
marker line.
- Displayed when the MARKER menu is set to
USER.
• USER MARKER H2
- Used to set the position of the second horizontal
marker line.
- Displayed when the MARKER menu is set to
USER.
• USER MARKER V1
- Used to set the position of the first vertical
marker line.
- Displayed when the MARKER menu is set to
USER.
• USER MARKER V2
- Used to set the position of the second vertical
marker line.
- Displayed when the MARKER menu is set to
USER.
R-7D
+ 0
+1920
+ 0
+1080
• GRID ENABLE
- Used to activate the GRID display function.
* This function is not supported in R-7D.
• GRID TYPE
- Used to select the GRID type.
- Available GRID types are 3x3, 4x4, 5x5 and 6x6.
* This function is not supported in R-7D.
• GRID THICKNESS
- Used to set the thickness of the GRID.
- Thickness level is from 1 to 5.
* This function is not supported in R-7D.
17
Field Production Monitor
05 MENU OPERATIONS
[4] DISPLAY / VIDEO
DISPLAY / VIDEO 이
SCAN
ASPECT
H/V DELAY
BLUE ONLY
USER ASPECT HOR
USER ASPECT VER
3G FORMAT
ZOOM
ZOOM SPLIT
CCAPTION
CC INFO
CHANNEL(608)
SERVICE(708)
ZERO SCAN
16:9
OFF
OFF
NORMAL
OFF
OFF
OFF
CC1
SERVICE 1
R-7D
+1920
+1080
PAGE(1/2)
• SCAN
- Used to change the Scan mode. Scroll up and
down using the Knob and the mode will chang
as the following sequence. [Zero Scan] -> [Over
Scan] -> [Pixel-To-Pixel] -> [User Aspect]
* [USER ASPECT]: User can control the aspect
ratio by adjusting width and height of the display.
* See section “7. Other Functions [1] User
Aspect” for more information.
• ASPECT
- Used to change the Aspect Ratio.
- Regardless of the original Aspect ratio of the
input signal, the Aspect Modes are changed as
follow sequence. : [16:9][4:3][2.35:1][1.85:1][15:9]
[16:10][Anamorphic1.3x][Anamorphic1.5x]
[Anamorphic2.0x][Auto]
* [Auto] mode enables the Aspect Ratio of the
output signal to be synchronized to the original
Aspect Ratio of the input signal.
• H/V DELAY
- Used to monitor the Blanking area of H sync and
V sync.
• BLUE ONLY
- Used to switch in the order of [Off]-[Blue Only]-
[Mono]-[Off].
- Press the button to remove red and green
components from the input signal and display
blue componet only.
- Press the button again to switch to mono-
chrome mode which has no chroma signal.
18
• USER ASPECT HORIZONTAL/USER ASPECT
VERTICAL
- Activated only when the [SCAN] mode is set to
[User Aspect] .
- User can adjust the Horizontal and Vertical size
of the screen.
- See section “7. Other Functions [1] User Aspect”
for more information.
• 3G FORMAT
- Used to select 3G-SDI A/B input format among
NORMAL MODE(AUTO - A 422 10BIT_YCbCr
50/60P), A 444 10/12BIT_YCbCr, A 444 10/12BIT_
RGB, A 422 12BIT_YCbCr, B 444 10/12BIT_YCbCr, B
444 10/12BIT_RGB, B 422 12BIT_YCbCr, B 422
10BIT_YCbCr 50/60P.
- In NORMAL MODE, automatically detected when
Payload signal is contained.
• ZOOM
- Used to magnify the image up to 90% on a pixel
basis and display on full screen.
* (e.g.,10% Zoom : If the input signal’s resolution is
1920 x 1080, only 90% (1728(H) x 972(V)) of the
image would be shown on full screen without
the remaining 10% (192(H) x 108(V)) of the
image.)
* See section “7. Other Functions -> [4] Zoom” for
more information.
• ZOOM SPLIT
- Used to magnify the image.
- Used to zoom the specified area sequentially.
- Designable areas are Left-Top, Right-Top, Left-
Bottom, Right-Bottom and Center.
05 MENU OPERATIONS
[4] DISPLAY / VIDEO
DISPLAY / VIDEO 이
SCAN
ASPECT
H/V DELAY
BLUE ONLY
USER ASPECT HOR
USER ASPECT VER
3G FORMAT
ZOOM
ZOOM SPLIT
CCAPTION
CC INFO
CHANNEL(608)
SERVICE(708)
ZERO SCAN
16:9
OFF
OFF
NORMAL
OFF
OFF
OFF
CC1
SERVICE 1
R-7D
+1920
+1080
PAGE(1/2)
• CLOSED CAPTION
- This item controls the Closed Caption.
- Available modes are OFF, 708, 608(LINE21) and
608(ANC).
* This fuction is not supported in R-5T.
• CC INFO
- Displays the current setting closed cation
information.
* This fuction is not supported in R-5T.
• CHANNEL (608)
- Sets the Channel of Closed Caption 608
- Available modes are CC1 ~ CC4.
* This fuction is not supported in R-5T.
• SERVICE (708)
- Sets the service of Closed Caption 708.
- Available modes are Service 1 ~ Service 6.
* This fuction is not supported in R-5T.
Field Production Monitor
19
Field Production Monitor
05 MENU OPERATIONS
[4] DISPLAY / VIDEO
DISPLAY / VIDEO 이
DSLR
DSLR SCALE
TIMECODE
FOCUS ASSIST
FOCUS AS COLOR
FOCUS AS LEVEL
ARRI CAM STATUS
LD INFO
INDEX LETTER
R-7D
+0
PAGE(2/2)
• DSLR
- Select the DSLR camera to be used with the
monitor. Available mode is [CANON 7D].
* DSLR cameras’ screen size and aspect ratio of
Live / Record / Playback modes vary depending
to their manufacturer.
• DSLR SCALE
- This is a special function for CANON/NIKON DSLR
cameras.
- Used to scale the image with different resolution
as to the operation mode(Live View/ Record/
PlayBack) of the camera to fullfill the screen.
* See section “7. Other Functions [08] DSLR
SCALE” for more information.
• TIMECODE
- Used to set the Time Code.
- Available modes are [Off], [VITC], and [LTC].
• FOCUS ASSIST
- Focus Assist helps the shooters to easily find out
the exact area in the picture with good focus,
simply by adding colors on the shape or boundaries
of the object in the picture.
- Activates in order of [Mono On]-[Color On]-[Off]
* [Color On] : Only the boudary of the area with
good focus is displayed with the designated color.
*[Mono On] : The boundary of the area with
good focus is colored with the designated color,
while the rest of the areas(pixels) have only
Y’(Luma) signals to be black & white image.
* See section “7. Other Functions [06] Focus
Assist” for more information.
• FOCUS AS COLOR (Focus Assist Color)
- Used to select a color for Focus Assist among
red, green and blue.
- This feature is available only when the Focus
Assist mode is activated.
• FOCUS AS LEVEL (Focus Assist Level)
- Used to set the edge difference value between
the edges in an image.
- Available values are from 0 to 100. Larger the
value the more sophisticated the detail detection.
- Designated color is displayed when the difference
of the edges exceeds the previously set value.
- This feature is available only when the FOCUS
ASSIST mode is activated.
• ARRI CAM STATUS (Arri Cameara Status)
- Used to set the Status Information provided by
the ARRI ALEXA Camera.
- The screen is squeezed when this setting is
enabled. (1742x980)
• LDS INFO (Lens Data System Information)
- Used to se set the information display of the
Lens Data System.
- Activates in the order of [Lens name]–[Focal
length]–[Iris]–[DOF Min]–[Focus distance]–
[DOF max].
• INDEX LETTER
- Used to set the monitor identification
the screen.
character notation in the upper right corner of
20
Field Production Monitor
05 MENU OPERATIONS
[5] WAVEFORM
WAVEFORM
ENABLE
TYPE
INTENSITY
TRANS
SIZE
LINE WAVEOFORM
SEL LINE POS
LUMA CHECK
LUMA ADJUST
RANGE ERROR
Y MAX
Y MIN
C MAX
C MIN
Y PICTURE BLINK
C PICTURE BLINK
R-7D
1
• ENABLE
- Used to activate/ deactivate the Waveform
which is selected in the Waveform/Vectorscope
Type menu.
• TYPE
- This function sets the Waveform and Vectorscope.
- Available options are different according to the
Input signal.
- Activates in the order: YCbCr: Off - Waveform
- Vectorscope - Waveform Wide - Waveform
YCbCr - RGB(Conv.)-Wave_Vector - Vector_YCbCr
- Full Waveform(Y) - Full Vectorscope.
• INTENSITY
- Used to set the brightness level of the Waveform/
Vectorscope display from 1 to 63.
- The higher the number the brighter the
waveform will be.
• TRANS (Transparency)
- Used to select the transparency option of the
Waveform/ Vectorscope between Opaque and
Blend.
- Even if the option is set to [Opaque], it will
automatically turn to [Blend] when the main
OSD overlaps the waveform/vectorscope.
And turns back to [Opaque] when the main OSD
disappears.
0
0
0
0
0
0
• SIZE
- Adjust the size of the Waveform or Vectorscope.
- Can select among [NORMAL] and [LARGE].
• LINE WAVEFORM
- This item is utilized to display the entire data or
one line data on the Waveform.
• SEL LIN POS (Select Line Position)
- Used to select specific Vertical Line for Waveform/
Vectorscope.
- This is available when LINE Waveform is activated.
- Use the Knob to select a desired vertical line.
- Control range varies according to the resolution
of the input SDI signal.
* PAL : Min. 1, Max. 625
* NTSC : Min. 1, Max. 525
* 720p : Min. 1, Max. 750
* 1080i : Min. 1, Max. 1125
* 1080p : Min. 1, Max. 1125
• LUMA CHECK
- Displays the Luma(Y’) level of the input image
in colors.
- Can select between [Color Pattern] or [Zebra
Pattern].
- Each pixel’s Y’ analized and changed to a certain
color or zebra pattern according to the Index on
the right side of the screen.
- When a pixel’s Y’ level is under 0%(16), the color
/ diagonal line will be colored Green.
- When the pixel’s Y’ level is over 100%(235), the
color / diagonal line will be colored Red.
- When the Y’ level of a pixel is between 0~100%,
the pixel is displayed with Gray, except for
selected Luma Zone.
- In the [Color Pattern] mode, a 5% zone of the
selected Y’ level will be colored Pink(5%) and
±10% will be colored Yellow(-10% from Pink) and
Cyan(+10% from Pink).
- In the [Zebra Pattern] mode, ± 5% of the selected
Y’ Level will be displayed with diagonal lines.
21
Field Production Monitor
05 MENU OPERATIONS
[5] WAVEFORM
WAVEFORM
ENABLE
TYPE
INTENSITY
TRANS
SIZE
LINE WAVEOFORM
SEL LINE POS
LUMA CHECK
LUMA ADJUST
RANGE ERROR
Y MAX
Y MIN
C MAX
C MIN
Y PICTURE BLINK
C PICTURE BLINK
R-7D
1
• LUMA ADJUST
- Used to set the Y’ level to be colored Yellow, Pink
and Cyan in [Color Pattern] mode, or to set Y’
level zone to be displayed with diagonal lines in
[Zebra Pattern] mode simply by scrolling the
Knob.
- Available values are 0w ~ 100%.
* See section “7. Other Function [5] Luma(Y’) Zone
Check” for more information.
• RANGE ERROR
- Used to set whether or not to activate Y MAX,
Y MIN, C MAX, C MIN, Y PICTURE BLINK and C
PICTURE BLINK functions.
- The values of Y MAX, Y MIN, C MAX, C MIN are
indicated in Waveform/Vectorscope.
- If [Y PICTURE BLINK] or [C PICTURE BLINK] is
enabled, the section of image that exceeds the
selected values of Y MAX, Y MIN, C MAX and C
MIN shall blink.
* In the case of RGB input, Range Error is not
supported.
* See section “7. Other Function [7] Range Error”
for more information.
0
0
0
0
0
0
• Y MAX
- Used to set the maximum Luma(Y’) level from 0
to 255.
- Pixels with values exceeding the max Y’ level will
blink on the screen, and be displayed in red on
the Waveform.
•
Y MIN
- Used to set the minimum Luma(Y’) level from 0
to 255.
- Pixels with values exceeding the max Y’ level will
blink on the screen, and be displayed in red on
the Waveform.
•
C MAX
- Used to set the maximum chroma(C’) level from
0 to 255.
- Pixels with values exceeding the max Y’ level will
blink on the screen, and be displayed in red on
the Waveform.
•
C MIN
- Used to set the minimum chroma(C’) level from
0 to 255.
- Pixels with values exceeding the max Y’ level will
blink on the screen, and be displayed in red on
the Waveform.
•
Y PICTURE BLINK
- Used to set whether or not to blink pixels with
values exceeding Y MAX and Y MIN.
•
C PICTURE BLINK
- Used to set whether or not to blink pixels with
values exceeding C MAX and C MIN.
22
Field Production Monitor
05 MENU OPERATIONS
[6] AUDIO
AUDIO
VOLUME
Em. AUD LEFT
Em. AUD RIGHT
LEVEL METER
LVM DISPLAY
LVM REFERENCE
LVM SIZE
PEAK DECAY TIME
CH01
CH02
OFF
PAIR
-18dB
SMALL
R-7D
0
0
• VOLUME
- Used to control the output volume for the
[AUDIO OUT] on the back of the monitor.
- Control range is from 0 to 30.
• Em. AUD LEFT (Embedded Audio Left)
- Used to set embedded audio channel for left
audio out of [AUDIO OUT] terminal on the back
of the monitor.
- Available values are between CH1~CH16 and
Ext..
* In the HDMI mode, Left is set to CH1.
• Em. AUD RIGHT(Embedded Audio Right)
- Used to set embedded audio channel for right
audio out of [AUDIO OUT] terminal on the back
of the monitor.
- Available values are between CH1~CH16 and
Ext..
* In the HDMI mode, Right is set to CH2.
• LEVEL METER
- Used to set the Level Meter for the embedded
audio.
- Available options are :
SDI Input : [Off]-[16CH(Hor.)]-[16CH(Ver.)]
HDMI Input: [Off]-[2CH(Hor.)]-[2CH(Ver.)]
* 16 CH(HOR.) : Displays 8 channels on top
left and 8 channels on top right of the screen
horizontally.
* 16 CH(VER.) : Displays 8 channels on center
left and 8 channels on top right of the screen
vertically.
• LVM DISPLAY (Level Meter Display)
- Used to set the display method for audio level
meter.
- Available modes are Group and Pair.
* In the HDMI mode, the mode is set to Pair.
• LVM REFERENCE (Level Meter Reference)
- Display the default audio level meter value,
- Available options are -18dB and -20dB.
- Audio level meter within selected value turns to
green and exceeded audio level is displayed in
yellow.
- Audio level exceeding -4dB is displayed in red.
• LVM SIZE (Level Meter Size)
- Used to control the size of the audio level meters.
- Available options are NORMAL and LAGRE.
• PEAK DECAY TIME
- Sets the reduction time for max value indication
of audio signals.
- Control range is from MIN 0 to MAX 100. Bigger
number means a longer display time for max
value.
23
Field Production Monitor
05 MENU OPERATIONS
[7] SYSTEM / GPI / UMD
SYSTEM / GPI / UMD
DEFAULT
LUMINANCE
INTERNAL PAT
DISPLAY ENABLE
ECO SAVING
FAST MODE
KEY LED
OFF
OFF
OFF
OFF
0
OFF
SW UPGRADE OFF
VERSION
SERIAL NUM
R-7D
SW 00 FPGA 00 BOARD 00
12345678
100
PAGE(1/3)
• DEFAULT
- Used to initialize OSD values to factory default.
- Available modes are DEFALUT and FACTORY.
- In the DEFALUT mode, except for the stored 3D
LUT, all values are initialized.
- In the FACTORY mode, all values are initialized to
factory default.
• LUMINANCE
- Used to indicate the current Luminance value .
- In the case of System Default, the value returns
to factory default(after color calibration).
- Available values are from 0 to 50.
• INTERNAL PAT (INTERNAL PATTERN)
- Generates ColorBar, Pludge and Grayscale
Pattern internally.
- Selectable range for Gray Pattern is from 0% to
100% with 5% increment.
* See section “7. Other Function -> [09] Internal
Pattern” for more information.
• DISPLAY ENABLE
- Used to set the LUMINANCE to the minimum
value when the time set in the still image output
is exceeded.
- When video is output or the MENU button is
pressed, the LUMINANCE is reset to the original
value.
- Settable options are ON, 5MIN, 10MIN, 20MIN
and 30MIN.
- In the Function Key, the screen can be turned
ON/OFF immediately by user’s choice.
24
• ECO SAVING
- Used to save power consumption automatically
when there is no monitor signal.
- When the signal is supplied, the brightness of
the monitor will be changed to the set value.
• FAST MODE
- Used to minimize the de-interlacing processing
time delay and improve the quality of fast
moving and fine details under the interlaced
format.
- Since the function of this feature is to minimize
the de-interlacing delays, it will not be effective
under the progressive format.
- Feature bypasses deinterlacer, playing back 2 full
fields per frame. Also reduces signal processing
delay for reduced audio/video delay.
* This function is not supported in R-7D.
●
KEY LED
- Locks the Function Key functions except the
MENU and UP/DOWN button.
* For the R-7D, the KNOB LOCK menu supports the
same function.
• S/W UPGRADE
- Used to upgrade the firmware using USB (Thumb
drive).
* See section “7. Other Functions -> [11] Firmware
Upgrade” for more information.
• VERSION
- Displays current firmware version.
• SERIAL NUM (Serial Number)
- Displays the serial number of the monitor.
Field Production Monitor
05 MENU OPERATIONS
[7] SYSTEM / GPI / UMD
SYSTEM / GPI / UMD
GROUP ID
MONITOR ID
RS-422 BAUD
PIN 1
PIN 2
PIN 3
PIN 4
PIN 5
PIN 6
PIN 7
PIN 8
0
0
0
HDMI CHANNEL
SDI A CHANNEL
SDI B CHANNEL
TALLY RED
TALLY GREEN
BLUE ONLY
POWER ON/OFF
GND
R-7D REMOTE (RJ-45)
1: Pin1
2: Pin2
3: Pin3
4: Pin4
5: Pin5
6: Pin6
7: Pin7
8: GND
1
PAGE(2/3)
• GROUP ID
- Used to group the monitors to control the
monitors by group when the monitors are
controlled by using RS-422 communication.
• MONITOR ID
- Used to set the ID of each monitor for using
RS-422 communication.
- Available values are between 0,2,4 ~ 98.
• RS-422 BAUD
- Used to set the Baud Rate for the RS-422
communication.
- Available values are 9600, 14400, 19200, 38400,
and 115200.
●
PIN1~PIN8
- This item activates/ inactivates the REMOTE
function.
- The user may designate a function for each pin
and each pin’s default setting is as follows.
- The default settings are as follows:
PIN 1 : HDMI CHANNEL
PIN 2 : SDI-A CHANNEL
PIN 3 : SDI-B CHANNEL
PIN 4 : TALLY RED
PIN 5 : TALLY GREEN
PIN 6 : BLUE ONLY
PIN 7 is POWER ON/OFF use only, PIN 8 is GND
Menu
Classification
PIN 1~6
Settable Values
NONE
HDMI CHANNEL
SDI-A/B CHANNEL
TALLY RED
TALLY GREEN
BLUE ONLY
MONO, ASPECT
HVDELAY
16:9 MARKER
15:9 MARKER
14:9 MARKER
13:9 MARKER
4:3 MARKER
4:3 ON AIR MARKER
1.85:1 MARKER
2.35:1 MARKER
1.85:1 & 4:3 MARKER
CENTER MARKER
SAFETY AREA 80%
SAFETY AREA 88%
SAFETY AREA 90%
SAFETY AREA 93%
SAFETY AREA 100%
8
25
Field Production Monitor
05 MENU OPERATIONS
[7] SYSTEM / GPI / UMD
SYSTEM / GPI / UMD
UMD ID
UMD DISPLAY
UMD CHARACTER
UMD CHAR COL
UMD B.G. TRANS
UMD B.G. SIZE
D-UMD TALLY TYPE
TALLY 1 COLOR
TALLY 2 COLOR
TALLY 3 COLOR
TALLY 4 COLOR
0
OFF
CHANNEL 1 ▼
WHITE
OPAQUE
SMALL
DEFAULT
OFF
OFF
OFF
OFF
R-7D
• UMD CHARACTER
- Used to customize the characters for Under
Monitor Display.
- Press the [ENTER] button to activate the Virtual
Key Board. Alphabets, numbers and special
symbols are available. - There is a special buttons
at the bottom right of the Virtual Key Board.
- Left Cursor / Space / Right Cursor / Clear Current
Cursor / Clear All (from left to right)
PAGE(3/3)
• UMD ID
- Used to set the ID of each monitor for the
DYNAMIC UMD setting of the UMD DISPLAY
using the RS-422 communication.
• UMD DISPLAY
- Used to set the UMD, ANC and Dynamic UMD.
- Available modes are OFF, UMD, ANC, D-UMD(S-
8C), D-UMD(S-16C) and D-UMD(D-8C).
* UMD : Displays user customized 8 characters on
screen.
* ANC : Displays characters embedded in SDI
signal.
* D-UMD(S-8C) : Displays the incoming data of 8
characters and tally signal from the TSL protocol
(V3.1).
* D-UMD(S-16C) : Displays the incoming data of 16
characters and tally signal from the TSL protocol
(V3.1).
* D-UMD(D-8C) : Displays the incoming data of
two pairs of 8 character strings and tally signals
from the TSL protocol(V3.1).
- When setting the D-UMD(S-8C), D-UMD(S-16C)
and D-UMD(D-8C) mode, the RS-422 Baud
setting in the System menu is automatically
changed to [38400].
- Up to 8 characters can be set.
• UMD CHAR COL (UMD Character Color)
- Used to set the character color of UMD.(White/
Red/Green/Yellow/Cyan/Magenta)
- Activates only when the [D-UMD tally type] is set to [Default], [User color], [BG. Color], [User tally] or [User BG.].
• UMD B.G TRANS
- Used to set the transparency of the UMD
character’s background box.
- Available modes are [Opaque], [50%], [85%] and
[100%].
• UMD B.G SIZE
- Used to adjust the size of UMD font and
character’s background box.
- Available modes are [Small] and [Large].
• UMD B.G TRANS (UMD Background Transparency)
- Used to set the transparency of the UMD
character’s background box.
- Available modes are [Opaque], [50%], [85%]and
[100%].
• UMD B.G SIZE (UMD Background Size)
- Used to adjust the size of UMD font and
character’s background box.
- Available modes are [Small] and [Large].
26
Field Production Monitor
05 MENU OPERATIONS
[7] SYSTEM / GPI / UMD
SYSTEM / GPI / UMD
UMD ID
UMD DISPLAY
UMD CHARACTER
UMD CHAR COL
UMD B.G. TRANS
UMD B.G. SIZE
D-UMD TALLY TYPE
TALLY 1 COLOR
TALLY 2 COLOR
TALLY 3 COLOR
TALLY 4 COLOR
0
OFF
CHANNEL 1 ▼
WHITE
OPAQUE
SMALL
DEFAULT
OFF
OFF
OFF
OFF
R-7D
• TALLY COLOR
- Used to set the color of each Tally 1, Tally 2,
Tally 3 and Tally 4.
- Available colors are Red, Green and Yellow.
• B0:0 B1:0 ~ B0:1 B0:1
- Used to set the color of the Byte0 and Byte1 of
Control Byte based on TSL Protocol V3.1.
- Available colors are Off, White, Red, Green,
Blue, Yellow, Cyan and Magenta.
PAGE(3/3)
• D-UMD TALLY TYPE
- Used to set the Tally type in the D-UMD(D-8C).
- Available values are DEFAULT and USER COLOR.
* Default : Existing TV Logic operating system(VRT)
* User color : User configuration settings on each
Tally color type.
- Tally1 Color ~ Tally4 Color are activated when
USER COLOR is selected.
* Character : Tally is displayed with the character
color. Activates the same as [Default] mode.
* B.G. color : Tally is displayed as the background
of character. Activates the same as [Default]
mode.
* User tally : The bit 0 & bit 1 of TSL Protocol
Control Byte receives the input signal and
displays Tally by user’s set (Off, White, Red,
Green, Blue, Yellow Cyan, Magenta)
* User char. : Activates in the same way as the
User Tally and the Tally is displayed by the
Character color.
* User B.G. : Activates in the same way as the
User Tally and the Tally is displayed in the
background of the character.
27
Field Production Monitor
05 MENU OPERATIONS
[7] SYSTEM / GPI / UMD
<Dynamic UMD Protocol (TSL V3.1)>
* Transmission (18 Byte) (PC or Device -> Monitor)
HEADER
(1 BYTE)
CONTROL
BYTE(1 BYTE)
DISPLAY DATA
(16 BYTE)
* [HEADER] : Display address (0~126) + 80 hex.
* [CONTROL BYTE]
bit 0 : Tally 1 (1=on, 0=off)
bit 1 : Tally 2 (1=on, 0=off)
bit 2 : Tally 3 (1=on, 0=off)
bit 3 : Tally 4 (1=on, 0=off)
bit 4 : bright data
(Not used)
bit 5 : bright data
(Not used)
bit 6 : reserved
(Not used)
bit 7 : cleared to 0
(Not used)
* [DISPLAY DATA] : 16 displayable ASCII characters.
Tally1 CHANNEL1 Tally2 Tally3 CHANNEL1 Tally4
28
Field Production Monitor
05 MENU OPERATIONS
[7] SYSTEM / GPI / UMD
• Tally Type - Default
- S-8C(Single 8 Character) & S-16C(Single 16 Character)
Bit 1
(Tally2)
Bit 1
(Tally1)
Operation
0
0
1
1
0
1
0
1
CHANNEL1
CHANNEL1
CHANNEL1
CHANNEL1
- D-8C(Dual 8 Character)
Bit 1
(Tally4)
Bit 1
(Tally3)
0 0
0 1
1
1
0
1
Operation
CHANNEL1
CHANNEL1
CHANNEL1
CHANNEL1
●
D-UMD TALLY TPYE - USER COLOR
- Used to set the color of the TALLY1 ~ TALLY4.
Activates as follows when the UMD DISPLAY is set to D-UMD(D-8C) and the D-UMD TALLY TYPE and the TALLY1 ~ TALLY4 COLOR is set to as below.
D-UMD TALLY TYPE
TALLY1 COLOR
TALLY2 COLOR
TALLY3 COLOR
TALLY4 COLOR
USER COLOR
RED
GREEN
RED
YELLOW
CHANNEL1 CHANNEL1
29
Field Production Monitor
06 BUTTON FUNCTIONS
INPUT BUTTON & FUNCTION KEY SET BUTTON
[1] INPUT BUTTON
SDI A
SDI B
HDMI
NO VIDEO
• R-Series unit is capable of processing SDI/HDMI
Input signal.
1. Press the[MENU<EXIT]button on the front of
the monitor for more than 2 seconds and
activate the OSD menu as shown on the below.
2. Input resolution displays on the bottom of the
OSD screen.
3. Press the [MENU<EXIT] button again to remove
the OSD menu from display.
* If no image displays after selecting the desired
input mode, check and make sure that your
connection is not lost or disconnected.
[2] FUNCTION KEY SET BUTTON
HDMI
NO VIDEO
ASPECT
MARKER
H/V DELAY
BLUE ONLY
ZOOM
ZOOM SPLIT
FREEZE
DSLR SCALE
AUDIO LVM
TIME CODE
FOCUS ASSIST
WAVEFORM
LUMA(Y`) ZONE
RANGE ERROR
MAX BRIGHTNESS
CAMERA LUT
DISPLAY ENABLE
INPUT SELECT
ARRI METADATA
• Used to make a quick setting of the Function
Key.
1. Press the function button(F1~F2) on the front
of the monitor for more than 2 seconds and
activate the OSD menu as follows.
2. Move to a desired function with the Knob and
press the Knob to select.
3. Once the function is set, press the Function
button(F1~F6) to activate the function.
30
Field Production Monitor
07 OTHER FUNCTIONS
[01] USER ASPECT
• Used to adjust the Width /Height display ratio.
1. Select [Aspect] mode in the OSD menu by pressing the function button on the right top of the monitor
to activate the [USER ASPECT] mode.
2. After the activation, press the Knob to begin controlling. Adjust the ratio using the knob.
USER ASPECT
WIDTH +1920
HEIGHT +1080
- Adjust the ratio using the Knob.
- Control range for width: 0~1920.
- Control range for height : 0~1080.
- The size-adjusted picture always stays in the center of the screen.
- The size can be adjustable with 2 increment and decrement.
# To adjust the 16:9 aspect ratio of 1920X1080 resolution into 2.35:1 aspect ratio, adjust the width and
height as 1280 x 544.
31
Field Production Monitor
07 OTHER FUNCTIONS
[02] WAVEFORM / VECTORSCOPE
●
WAVEFORM Y
- Displays the Luma(Y’) component of the input signal into waveform.
• The Waveform/ Vectorscope function can be
used only when the input signal is YUV.
• In the case of RGB input, Waveform RGB is supported.
• Available modes in the YUV signal:
- Waveform Y
- Vectorscope
- Waveform Wide
- Waveform Y Cb Cr
- RGB(Conv.)
- Wave_Vector
- Vector_YCbCr
- Full Waveform(Y)
- Full Vectorscope
●
WAVEFORM Cb, Cr
- Displays the Cb, Cr components of the input signal into waveform.
●
VECTORSCOPE
- Displays the color components ‘B-Y’ and ‘R-Y’ of the input signals onto the X-Y axis.
- Two different types of Vetorscopes are displayed according to SD or HD input signals.
- 100% and 75% scales are indicated on the Vetorscope.rm.
100%
75%
32
Field Production Monitor
07 OTHER FUNCTIONS
[03] LINE SELECT (WAVEFORM/VECTORSCOPE)
• Used to select specific Vertical Line for WaveForm/VectorScope.
- This is available when LINE WaveForm is activated.
- To activate this feature, go to [Waveform]-[Waveform/Vector]-[Line Waveform]-[Select Line Position] and
use the Knob to select a vertical line.
- Selected line is indicated in White on the screen.
- Control range varies according to the resolution of the input SDI signal.
* PAL : 0~625
* NTSC : 0~525
* 720p : 0~750
* 1080 i/p : 0~1125
* Selected line is indicated on the screen.
LINE
POSITION
33
Field Production Monitor
07 OTHER FUNCTIONS
[04] ZOOM
• Used to magnify the input signal from 0% to 90%.
- Supports Zoom Width Scroll / Zoom Height Scroll function.
- Zooms IN/OUT focused on the scrolled area.
<ZOOM OFF>
<ZOOM 50%> <ZOOM 75%>
34
Field Production Monitor
07 OTHER FUNCTIONS
[05] LUMA (Y') ZONE CHECK
• COLOR PATTERN TYPE
- Displays the Luma(Y’) level of the input image in colors.
- Y’ ≥ 100% : Pixels with higher Y’ level than 100 turn to red.
- Y’ ≤ 0% : Pixels with lower Y’ level than 0 turn to green.
- Pixels with Y’ levels designated by the user are displayed in following colors - yellow, pink, cyan.
- Factory Default Y’ (Border line between pink and yellow) level is 75% and the pink color is
assigned to pixels with Y’ level from 70% to 75%.
- Yellow color is assigned to pixels with Y’ level from 75% to 85%, and Cyan from 60% to 70%.
- This function is designed for a better performance in setting the exposure when shooting with DSLR
cameras.
<Luma Zone Check OFF> <Luma Zone Check ON_Color Pattern Type>
• ZEBRA PATTERN TYPE
- Displays the pixels with designated Luma(Y’) levels with zebra pattern.
- Y’ ≥ 100%: Pixels with Y’ level over 100% turn to red diagonal stripes.
- Y’ ≤ 0% : Pixels with Y’ level under 0% turn to green diagonal stripes.
- User defined Y’ levels are displayed as black diagonal stripes.
- Factory Default Y’ level is 70% and the pixels with Y’ level from 65% to 75% is displayed with zebra pattern.
- Pixels with 10% of Y’ level is displayed as black diagonal stripes.
- This function is designed for a better performance in setting the exposure when shooting with vDSLR
cameras.
<Luma Zone Check OFF> <Luma Zone Check ON_Zebra Pattern Type>
35
Field Production Monitor
[06] FOCUS ASSIST
• Focus Assist function assigns a color to the pixels in the shape or the boundary of the image to inform
the user to achive the best focus.
- With this function, user can easily differenciate the focused area from the out-focused area especially
when shooting with a shallow depth of field.
- Available types are [Mono] and [Color] types.
* [Mono] : Background image is mono type.
* [Color] : Background image is original color type.
<Focus Assist ON> <Focus Assist Mono ON>
36
Field Production Monitor
07 OTHER FUNCTIONS
[07] RANGE ERROR
• Pixels with Y’ or C’ levels exceeding the designated levels of Y MAX, Y MIN, C MAX and C MIN shall blink.
- Analyzes the input signal’s Luma(Y’) and chroma information(C’) and if the input signal exceeds the
designated minimum value and maximum value, the pixel shall blink. This function is to help the user to
easily find out any unwanted level of signals and for a better exposure setting.
* In the case of RGB input, Range Error is not supported.
<Range Error OFF> <Range Error ON>
37
Field Production Monitor
07 OTHER FUNCTIONS
[08] DSLR SCALE
• This function is designed for some DSLR cameras of Canon(7D) that output different resolution from
the operation mode (StandBy, Record, Play Back)
• Select the Camera model in the [Display/Vide]- [DSLR Camera Sel.] menu.
• CANON (5D/550D)
- In StandBy mode of Canon 5D Mark II, 1080i of HD resolution is indicated. However, real output resolution
is 1620x1080 so blank area is displayed on the screen because the 16:9 aspect ratio is not realized.
- In this case, use DSLR SCALE function to enlarge the 1920x1080 image and display full screen.
- In Recording mode of CANON 5D Mark II, the output resolution is SD(480p).
- Although it is SD, the real output resolution is 640x390 not 720x480.
- DSLR SCALE function scales the 640×390 image to 1280x800(panel resolution) and display full screen.
※
Note
1. When you compare the circle chart or the camera shooting chart with DSLR connected monitor(HDMI)
and HDMI to SDI Conversion connected monitor, The function of Live/Rec 16:9 mode should be selected
to compare circle and it is equal to its actual. If the circle is compared in Live/Rec Full mode, the output
of the circle is deformed.
2. Both the DSLR Camera connected monitor and HDMI to SDI Conversion connected monitor should be
compared to circle in Zeroscan mode. It is deformed if user selects in Overscan and Underscan mode.
<DSLR Scale OFF> <DSLR Scale ON>
38
Field Production Monitor
[09] INTERNAL PATTERN
• Displays internally generated test patterns.
- The pattern consists of ColorBar and Pluge+ Grayscale Patterns. Full screen colors of various gray levels
(0~100%) are also embedded.
<Color Bar + Pluge Pattern> <Gray Pattern>
39
Field Production Monitor
07 OTHER FUNCTIONS
[10] ARRI CAM STATUS
• Used to display the camera status information provided by ARRI ALEXA camera on the OSD.
- Displays the information in the order: [Project FPS]-[Exposure Time]-[White Balance]-[White Balance CC]-
[Camera Index Letter] / [Lens Name]-[Focal Length]-[Iris]-[Focus Distance] / [Lens Squeeze Factor]-[Scene]
- When the Arri Cam Status is activated, the screen will be scaled to 1742 x 980.
40
Field Production Monitor
07 OTHER FUNCTIONS
[11] FIRMWARE UPGRADE
• The USB(Thumb drive) which contains the F/W file is needed for Firmware Upgrade.
• Select the SW UPGRADE in the SYSTEM menu.
1. Connect the USB to the USB Slot on the front of the monitor.
2. Select what to update among CPU / FPGA / ALL in [S/W UPGRADE].
3. When the USB connection is completed, the S/W upgrade starts and the progress displays on the
bottom left side of the screen.
4. If the USB doesn’t connect properly or there is no fi le in the specifi ed location, the error message will
be displayed on the bottom left side of the screen and the upgrade won’t start.
5. In that case, check the USB or the file location and try again.
• After USB connection, turn off and then on the monitor.
41
Field Production Monitor
08 VIDEO SUPPORT RESOLUTION
INPUT SIGNAL INTERFACES SIGNAL FORMAT (SD SDI)
SD SDI single link
720x487 (59.94i)
720x576 (50i)
INPUT SIGNAL INTERFACES SIGNAL FORMAT (HD SDI)
YCbCr 4:2:2 10bit
HD SDI single link
1280x720 (23.98/24/25/30/50/59.94/60P)
1920x1080 (23.98/24/25/29.97/30p) (50/59.94/60I)
(24/25/29.97/30psf)
YCbCr 4:2:2 10bit
INPUT SIGNAL INTERFACES SIGNAL FORMAT (3G SDI)
3G-SDI (A/B) single link
1920x1080 (60p/59.94p/50p)
1920x1080 (30/29.97/25/24/23.98/
30sF/29.97sF/25sF/24sF/23.98sF)
1920x1080i (60/59.94/50)
1280x720((23.98/24/25/29.97/30/50/59.94/60P)
YCbCr 4:2:2 10bit
YCbCr 4:2:2 12bit
RGB 4:4:4 10bit / 12bit
YCbCr 4:4:4 10bit / 12bit
RGB 4:4:4 10bit
YCbCr 4:4:4 10bit
INPUT SIGNAL INTERFACES SIGNAL FORMAT (12G SDI)
12G-SDI (A)
Single link
12G-SDI 4096/3840x2160 (60/59.94/50p)
6G-SDI 4096/3840x2160 (30/29.97/25/24/23.98p)
YCbCr 4:2:2 12bit
INPUT SIGNAL INTERFACES SIGNAL FORMAT (12G SDI)
HD-SDI
Single link
1080p (60/59.94/50/30/29.97/25/24/23.98)
1080i/60/59.94/50)
720p (50/59.94/60p)
480i(60) / 576i(50)
480p(60) / 576p(50)
RGB 4:4:4 8bit / 10bit / 12bit
YCbCr 4:4:4 8bit / 10bit / 12bit
YCbCr 4:2:2 8bit / 10bit / 12bit
42
09 PRODUCT SPECIFICATIONS
Field Production Monitor
LCD
Input
Output
Input Signal
1 X BNC
1 X BNC
2 X RJ45
1 X BNC
1 X BNC
1 X RJ45
12G-SDI
6G-SDI
3G-SDI
HD-SDI
SD-SDI
Size
Resolution
Pixel Pitch
Color Depth
Viewing Angle (Typ.)
Luminance of white
Contrast Ratio
Display Area
1 X HDMI
HDMI
SMPTE ST 2082
SMPTE ST 2081
SMPTE-425M-A/B
SDI Input Signal
Formats
SMPTE-274M
SMPTE-296M
SMPTE-125M
ITU-R BT.656
Audio In
Audio Out
Power
Power Consumption (Approx.)
Tally Signal In/Out Level
Operating Temperature
Storage Temperature
Main Body Dimensions (mm/inch)
Main Body Dimensions with RMK (mm/inch)
Box Dimensions (mm/inch)
Weight
Basic Accessories
Optional Accessories
R-5T
5.5”
1920×1080 (16:9)
0.0213(W) x 0.0639(H) mm
16.7M (True)
160º(H)/160º(V)
500 cd/ m 2 (Center)
1,000 : 1
122.7(H)x69.0(V) mm
HDMI Input
3G-SDI
12G-SDI
RS-422, REMOTE
12G-SDI (Passive Through Out)
3G-SDI (Passive Through Out)
RS-422
11.88Gb/s
5.94Gb/s
2.970Gbps
1.485Gbps
270 Mbps
1080p(60/59.94/50/30/25/24/23.98)/
1080i(60/59.94/50)/720p(60/50)/480i(60)/480p(60)/576i(50)/576p(50)
3840x2160(60/50/59.94p)
3840x2160(30/29.97/25/24/23.98p)
1080p(60/59.94/50/30/29.97/25/24/23.98/30sF/29.97sF/25sF/24sF/23.98sF)
1080i (60/59.94/50)
1080p (30/29.97/25/24/24sF/23.98/23.98sF)
720p(60/59.94.50/30/29.97/25/24/23.98)
480i (59.94)
576i (50)
Embedded Audio
Speaker
DC 12V / 2.9A
35W
DC5V ±2V
0 ℃ to 45 ℃ (32 ℉ to 113 ℉)
-20 ℃ to 60 ℃ (-4
℉ to 140
℉)
439 X 87.5 X 118.7 (17.28 X 3.44 X 4.67)
480.2 X 87.5 X 141.7 (18.9 X 3.44 X 5.58)
555 X 180 X 250 (21.85 X 7.08 X 9.84)
2.9Kg/6.4lbs
-
DC Power adapter, Rack Mountable Kit
* The specification above may be changed without notice.
* When using a DC Adapter other than the one supplied by the manufacturer, please be advised that the
adapter with DC 12V/3A ~ 6A can be compatible with the monitor.
43
Field Production Monitor
09 PRODUCT SPECIFICATIONS
LCD
Input
Output
Input Signal
SDI Input Signal
Formats
SMPTE-274M
SMPTE-296M
SMPTE-125M
ITU-R BT.656
Audio In
Audio Out
Power
Power Consumption (Approx.)
Tally Signal In/Out Level
Operating Temperature
Storage Temperature
Main Body Dimensions (mm/inch)
Main Body Dimensions with RMK (mm/inch)
Box Dimensions (mm/inch)
Weight
Basic Accessories
Optional Accessories
1 X BNC
1 X BNC
2 X RJ45
1 X BNC
1 X BNC
1 X RJ45
12G-SDI
6G-SDI
3G-SDI
HD-SDI
SD-SDI
Size
Resolution
Pixel Pitch
Color Depth
Viewing Angle (Typ.)
Luminance of white
Contrast Ratio
Display Area
1 X HDMI
HDMI
SMPTE ST 2082
SMPTE-425M-A/B
R-7D
7.02”
1920×1200
0.07875(W) x 0.07875(H) mm
16.7M (True)
160º(H)/160º(V)
500 cd/ m 2 (Center)
1,200 : 1
151.2(H)x94.5(V) mm
HDMI Input
3G-SDI
12G-SDI
RS-422, REMOTE
12G-SDI OUT (Passive Through Out)
3G-SDI OUT (Passive Through Out)
RS-422
11.88Gb/s
5.94Gb/s
2.970Gbps
1.485Gbps
270 Mbps
1080p(60/59.94/50/30/25/24/23.98)/
1080i(60/59.94/50)/720p(60/50)/480i(60)/480p(60)/576i(50)/576p(50)
2160p (60/59.94/50/30/29.97/25/24/23.98/30sF/29.97sF/25sF/24sF/23.98sF)
2160i (60/59.94/50)
1080p (60/59.94/50/30/29.97/25/24/23.98/30sF/29.97sF/25sF/24sF/23.98sF)
1080i (60/59.94/50)
1080i (60/59.94/50)
1080p (30/29.97/25/24/24sF/23.98/23.98sF)
720p(60/59.94.50/30/29.97/25/24/23.98)
480i (59.94)
576i (50)
Embedded Audio
Speaker
DC 12V / 1.85A
22W
DC5V ±2V
0 ℃ to 45 ℃ (32 ℉ to 113 ℉)
-20 ℃ to 60 ℃ (-4
℉ to 140
℉)
430 X 120 X 50.5 (16.93 X 4.72 X 1.99)
480.8 X 132 X 73 (18.92 X 5.19 X 2.87)
555 X 165 X 230 (21.85 X 6.50 X 9.06)
2.46Kg / 5.42Ibs
-
DC Power adapter, Rack Mountable Kit
* The specification above may be changed without notice.
* When using a DC Adapter other than the one supplied by the manufacturer, please be advised that the
adapter with DC 12V/3A ~ 6A can be compatible with the monitor.
44
MEMO
Field Production Monitor
45
Field Production Monitor