PROGRAMMING THE TRANSMITTER
Thank you for your purchase of the Skylink garage door remote control, Model 69. There are 3 different steps you need to setup in order to use this universal garage door remote control to operate your existing garage door opener. These 3 steps are:
1) Frequency switch – select the correct frequency according to the brand of your existing garage door opener. Refer to
Step 1.
2) Brand jumpers – place the brand jumpers at the correct position according to the brand of your existing garage door opener. Refer to Step 2.
3) Code setting – Set the jumper connectors on the Model 69 so that they match the code setting of your existing garage door opener.
Refer to Step 3 or Step 4 depending on the brand of your garage door opener.
Please follow the detailed instructions below in order to setup the Skylink Model 69 to work with your existing opener.
STEP
1a. Locate frequency
switch on the top of
the transmitter:
(See diagram A)
Diagram A
1
- SET FREQUENCY SWITCH
USA
CANADA
A
390
390
B
318
318
C
310
D
300
315 310
1b. Determine the brand of your garage door opener and set the frequency switch to the corresponding position. (See chart 1)
Brand of your opener
Chamberlain
®
Lift-Master
®
Sears
®
Wayne Dalton
®
Master Mechanic
®
Genie
®
Overhead
®
Pulsar/Allister/Allstar
®
Linear
®
MegaCode
TM
Linear
®
M-O-M
®
Stanley
®
Multi-Code
®
Martec/Teckey
®
Skylink
®
UR-100
B
C
C
C
D/C
D
A
A
B
A
A
A
A
A
D/A
USA
Set switch to position Frequency
390
390
390
300/390
390
390
390
318
318
310
310
310
300/310
300
390
CANADA
Set switch to position Frequency
D
-
A
B
D
D
D
C/A
C/A
C/A
C/A
C/A
C/A
A
B
318
310
310
310
310
-
390
315/390
315/390
315/390
315/390
315/390
315/390
390
318
Chart 1
2a. To set the brand jumpers, open the case with a coin
(see diagram B).
Diagram B
A = “-”
B = “+”
B AT TE RY
Brand
Jumper
REMOVE JUMPER = “0”
Diagram C
STEP
2
- SET BRAND JUMPER
Code connector Location 2b. The Model 69 contains 2 brand jumpers and 12 code connectors (see diagram C). The brand jumpers are located just above the battery with markings “A” and
“B”. There are 2 connectors, one is placed on the “A” column, the other one is placed on the “B” column.
For each column, there is a connector. If the connector is placed on the top and middle post of that column, that column is set on “+”. If the connector is placed on the middle and bottom posts, that column is set on
“-“. If the connector is removed completely, that column is set on “0” (see diagram C). In order for the Model
69 to work with your existing garage door opener
(motor), you need to set the brand jumpers based on the brand of your existing garage door opener. Please set these 2 brand jumpers “A” and “B” based on the brand jumpers setting on chart 2. Please identify the group number on chart 2 in order to determine which is the next step to proceed.
For garage door openers belonging to groups 1
to 3, please follow step 3 of the procedures, this will complete the setup. No need to proceed to step 4.
For garage door openers belonging to groups 4
to 8, you can proceed directly to “Step 4 – Set
Code Connector” after you have successfully set the brand jumpers. Please skip step 3 below.
STEP
2
- SET BRAND JUMPER
Group Brand
1 Chamberlain ® , Sears ® , Lift-Master ®
(without DIP switches but with red, orange or green
2
learn button)
Chamberlain ® , Lift-Master ® , Sears ® , Wayne Dalton ® ,
Master Mechanic ® (without DIP switches but with
yellow, white, or gray learn button)
3* Genie ® Intellicode TM * (without DIP switches)
4
5
6
Genie ® (with DIP switches), Overhead ®
Chamberlain ® , Lift-Master ® , Sears ® , Wayne Dalton ® ,
Master Mechanic ® (with DIP switches)
Stanley ® , Multi-Code ® , Martec ®
7
8
Linear ® , Moore-O-Matic ®
Pulsar ® , Allstar ® , Allister ® , Linear ® MegaCode TM
Brand jumpers setting Proceed to
A
+
B
-
-
+
+
-
-
0
0
0
+
0
+
-
+
-
Proceed to Step 3.
Proceed to Step 4, skip Step 3.
Chart 2
* Note:
For Genie ® Intellicode TM , if the brand jumper for group 3 cannot operate your garage door opener properly, please use setting A “-”, B “+”.
STEP
3
- LEARN CODE
Note:
Proceed to this step only if the brand of your garage door opener belongs
to either group 1, 2 or 3 on chart 2. Otherwise, proceed to Step 4 - Set
code connector.
3a. If your existing garage door opener belongs to any brand from group 1,
2 or 3, then you should find a “learn” button from the garage door opener
(the unit with the motor located on the ceiling of your garage, see diagram D). Press this learn button for approximately 2 seconds. The
LED light beside the learn button will go on and then press the button on the Model 69 to activate it. The LED light on the garage door opener will flash then go off.
The Model 69 is now programmed to your existing garage door opener and will operate your garage door.
Programming is now completed and please refer to the “Battery” section of this manual for battery maintenance.
Diagram D
Garage Door
Opener (GDO)
‘Learn’ Button
STEP
4
- SET CODE CONNECTORS
Note:
Proceed to this step only if the brand of your garage door opener belongs to
either group 4, 5, 6, 7 or 8 on chart 2. Otherwise, proceed to Step 3 - Learn code.
4a. If the brand of your garage door opener belongs to groups 4 to 8, that means you need to program the correct code setting in order for the Model 69 to work with your existing garage door opener. There are 12 code connectors on
12 columns from 1 to 12 (see diagram E). Each column has one connector.
(see diagram F)
4b. Set the connectors numbered 1 through 12 to match the code setting of your existing transmitter or receiver. There are 2 places you can find out the code setting from a column of small switches of your existing garage door opener.
1) your existing transmitter (the unit you currently use to open your garage).
2) the receiver of your garage door opener (the unit with the motor mounted on the ceiling of your garage).
Diagram E Diagram F
4c. If the connector is placed on the top and middle posts, that column is set on “ + ” or “ON” or “CLOSE”. If the connector is placed on the middle and bottom posts, that column is set on “ - ” or “OFF” or “OPEN”. If the connector is removed completely, (not placed on any posts), it is set to “ 0 ” or the neutral position. (see
‘-’ or ‘OFF’ or ‘OPEN’ diagram G for examples of how to set a column
‘+’ or ‘ON’ or CLOSE ‘0’ = BLANK to the three different positions). When removing a connector to set a column to the neutral position, save the connector in case you change the code at a later date.
Diagram G
4d. To move the connectors, slide an opened paper clip into the side of a connector and lift. (see diagram H)
When repositioning connectors, place a connector on the two chosen posts, then push down on the connector with your finger.
Paper
Clip
Diagram H
Code connector setting to match your opener/motor
Linear
M-O-M
Stanley (310) Canada
Stanley (300)
Multi-Code
Chamberlain
Lift-Master
Sears
Wayne Dalton
Master Mechanic
Genie (9 positions)
Genie (12 positions)
Overhead
Martec/Teckey
Pulsar/Allister/Allstar
Position 1 to 8
Position 1 to 8
Position 1 to 10
Position 1 to 10
Position 1 to 10
Position 1 to 9
Position 1 to 9
Position 1 to 9
Position 1 to 9
Position 1 to 9
Position 1 to 9
Position 1 to 12
Position 1 to 9
Position 1 to 10
Position 1 to 9
+ OR -
+ OR -
+ OR - 11,12 set to ‘+’ or ‘-’
+ OR - 11,12 set to ‘+’ or ‘-’
+ OR - 11,12 set to ‘+’ or ‘-’
+, 0 (blank), OR -
+, 0 (blank), OR -
+, 0 (blank), OR -
+, 0 (blank), OR -
+, 0 (blank), OR -
+ OR -
+ OR -
+, 0 (blank), OR -
+ OR -
+, 0 (blank), OR -
11,12 set to ‘+’
STEP
4
- SET CODE CONNECTORS
Set the connectors numbered 1 through 12 to match the switches of your existing transmitter or receiver. If your garage door opener is manufactured by (Stanley ® , Genie ®
,
Multi-Code ®
, Linear
®
, Moore-O-Matic
® ) these switches may only have two positions, ( “ + , ON, CLOSED” and “ - ,
OFF, OPEN”). (see diagram I) Set the connectors on the model 69 to “ + ” if your existing switches are either “ +,
ON, CLOSE ” and set to “ - ” if your existing switches are either “ -, OFF, OPEN”. Do not use the blank position “0”.
If your existing transmitter has fewer than 12 switches, match only the first corresponding connectors. Leave the remaining posts blank (remove the connectors). Press the button on the transmitter.
If the garage door does not open, reverse all of the connectors on the model 69. The “ + ” will be changed to the “ - ” position and the “ - ” position will be changed to the “ + ” position. (see diagram J)
Original Position
Examples of how to set Model 69
Existing
Transmitter
Model 69
Reversed Position
If your garage door opener is manufactured by (Chamberlain ® ,Sears ®
, Lift-Master
® ,
Wayne Dalton ® , Pulsar ® or Master Mechanic ® ) the switches will have 3 positions,
(“ + , 0, - ”). Set the connectors on the model 69 to match their corresponding positions. If your opener is a Sears ® , Chamberlain ® or Lift-Master ® and the existing transmitter has three buttons, (see diagram K), the first connector in the model #69 may need to be changed to another position.
If your Chamberlain ® ,Sears ®
, Lift-Master
®
has 9 DIP switches, match them to the first 9 connectors on the model 69 and remove the last 3 connectors (connectors
10, 11, 12). If there are only 8 DIP switches on your Chamberlain ® ,Sears ®
, Lift-
Master ® , match them to the 2-9 position on the model 69 and remove the last 3 connectors (connectors 10, 11, 12). Now you may have to change the positioning of the #1 connector on the model 69. If the large button of Diagram K is used to open the garage door, set the #1 connector to “ - ” position. If the middle button is used, set the #1 connector to the
“ 0 ” or “blank” position. If the smaller button on the left is used, set the #1 connector to the “ + ” position.
Diagram K
Diagram I Diagram J
OPERATION
To operate the model 69 with your GDO properly, please press the button on the model 69.
NOTE:
Transmission range may be reduced with use on a metal garage door.
WARNING
If this transmitter triggers other garage doors in your neighborhood, change all your transmitters and receiver to a new code setting.
DO NOT let children use the garage door transmitter without adult supervision. Children can injure themselves or others by the garage door.
WARRANTY
If, within one year from date of purchase, this product should become defective
(except battery), due to faulty workmanship or materials, it will be repaired or replaced, without charge.
Proof of purchase is required.
BATTERY
12 volt alkaline battery (size 23A) included.
FCC
The Universal Garage Door Remote
Control is approved by the FCC and it complies with Part 15 of the
FCC Rules. Its operation is subject to the following two conditions :
1. This device may not cause harmful interference.
2. This device must accept any interference that may cause undesired operation.
WARNING:
Changes or modifications to this unit not expressly approved by the party responsible of compliance could void the user’s authority to operate the equipment.
NOTE
If your Skylink Universal Remote Control does not activate your Garage Door Opener, the reason may be that your GDO age or manufacturer is not listed on the compatibility chart.
The solution is the Skylink UR-100 Universal Receiver.
If you would like to order Skylink’s product or have difficulty getting your Skylink’s remote control to work, please :
1. visit our website FAQ at www.skylinkhome.com, or
2. email us at [email protected]
(reply within 24 hrs)
3. call our toll free at 1-800-304-1187 from Monday to
Friday, 9 am to 5 pm EST.
Skylink will not be held liable or responsible for any misuse or application of this product other than for its intended use.
CUSTOMER SERVICE
2213 Dunwin Drive
Mississauga, Ontario,
L5L 1X1, CANADA
(905)608-9223
(905)608-8744 FAX
Email:[email protected]
(Reply within 24 hrs)
Customer Service : (800)304-1187
From 9am to 5pm EST (Mon-Fri) http://www.skylinkhome.com
P/N. 101A193-001 Rev.1