Manual


Add to my manuals
10 Pages

advertisement

Manual | Manualzz
7*10W RGB 3-IN-1 SUPER BRIGHT LED PAR LIGHT
A
7
Unpacking:
Thank you for purchasing this product. Please read user guide for safety and before using
the product. Keep this manual for future reference. This product can create perfect light
programs and effects since it has passed a series of strictly tests before delivery. Please check
the attachments listed on the page after opening the carton. Immediately upon receiving
a fixture, carefully unpack the box. Check the box contents to ensure that all parts are present
and that they are in good condition. If any part appears damaged from shipping, or if the
box shows signs of mishandling, notify the shipper immediately. In addition, retain the box
and all the packing material for inspection.In any event, save the carton and all packing material
because, in case that you have to return the fixture to the factory, you will have to do so in its
original box, with its original packing.
1. LED Light: 1PCS 2. Power Cable: 1PCS 3. User Guide: 1PCS
Safty Notice:
Please read the following notes carefully because they include important safety information
about the installation,usage and maintenance of this product. It is important to read all these
notes before starting to work with this product.
LED Expected Lifespan В
LEDs gradually decline in brightness over time. HEAT is the dominant factor that leads to the
acceleration of this decline. Packaged in clusters, LEDs exhibit higher operating temperatures than in ideal
or singular optimum conditions. For this reason when all color LEDs are used at their fullest intensity, life of
the LEDs is significantly reduced. It is estimated that a viable lifespan of 40,000 to 50,000 hours will be
achieved under normal operational conditions. If improving on this lifespan expectancy is of a higher
priority, place care in providing for lower operational temperatures. This may include climatic-environmental
and the reduction of overall projection intensity.
\ À
There are no user serviceable parts inside the light. Any reference to servicing this unit you
may find from now on in this User Manual will only apply to properly C we certified
technicians. Do not open the housing or attempt any repairs unless you are o
Please refer to all applicable local codes and regulations for proper
installation of the light.
Keep this manual for future consultation. If you sell the light to another user,
make sure that they also receive this manual.
Page 1
Avoid direct eye exposure to the light source while the fixture 1s on. Always disconnect
the light from its power source before servicing. Always connect the light to a grounded
circuit to avoid the risk of electrocution.
This product is for indoor use only! Use only in dry locations. Keep this
device away from rain and moisture, excessive heat, humidity and dust. Do
not allow contact with water or any other fluids, or metallic objects.
Make sure there are no
flammable materials close to
the fixture(s) while operating.
Please prevent this light away
from from electrical shock
| Danger
Ler
When hanging this fixture, always secure it to a fastening device using a
/ > safety cable (not provided).
Power Always make sure that you are connecting the light to the proper voltage, as per the
110V 240V ||specifications in this manual or on the product's sticker. Never connect the light to a
Ground dimmer pack. Make sure that the power cable is not cracked, crimped or damaged. Ne
The maximum ambient temperature (Ta) is 104 F (40 C). Do not operate the
fixture at a higher temperature. In case of a serious operating problem, stop
using this product immediately!
Use cleaning tissue to remove the dust absorbed on the external lenses
periodically to optimize light output.
Do not remove or break the warranty label, otherwise it void the warranty.
Always replace with the exact same type fuse, replacement with anything
other than the specified fuse can cause fire or electric shock and damage your
unit, and will void your manufactures warranty.
There are no serviceable parts in the light. Please have all servicing and
adjustments made by a qualified service engineer.
Don't throw this product away just as general
trash, please dispose of this product following
the abandon electronic product regulation in your
country,
To protect the environment,
recycle packing material
wherever possible.
Page 2
@® Voltage: AC110V-130V/200V-250V, S0HZ-60HZ/ Fuse: 3A/250V
O Rated Power: 73W
O LED Light: 10W x 7pcs RGB LED diodes
O Working Modes: DMX, Sound Active, AUTO, Master-Slave
O DMX Control Channel: 3 and/or 7 channels
O Advanced LED technology, Popular using in world.
O Extremely long life (rated 60,000 to 100,000 hr.)
@ Very low power consumption, no duty cycle runs all light.
@ Super bright for indoor use.Built-in automated programs via stand alone mode by Menu Button.
O 4 Digit Digital LED Display
O Lighting effects: adjustable strobe speed, color change, adjustable brightness
@ 3 pin male & female XLR interface
@ Light body: plastic
@ Working condition: indoor use only
@ Working environment temperature: 0°C-40C
O Cooling system: air cool
O Item Size: 18cm*10cm
O Net weight: 1.1kg.
O Gross weight: 1.5Kg (inner box), Kg (outer box)
@ Inner box: 225*210*170(0.008m3), Outer box: 465*435*561(0.114m3), 12pes/carton
DMX IN
handle screw
Microphone
LCD Display
Pr AA naa AA
Cooling fan
LT LE N
nn nr
LED bulbs
Power supply
Input
handle screw
power switch
ON/OFF
key menu: menu,
enter, up, enter
WR
=
i te ipa аа
ENTER
MENU: DMX control/colors selection/
colors pulse/colors transition/ sound
control/amnual set
DOWN/UP: previous or next, increase or
decrease
Enter: confirm and save the selection
Description
d001---d512
Under DMX512 mode or Master/Slave mode; Under DMX512, 001---512
means the value, press Down/UP to increase or decrease the value, then press
ENTER to save the selection.
Manually color selection
C001---C064 |001--255: 255 kinds of static color; Under Uoff white color Off MODE, 0--64
Value has 64kinds of static colors, press Down/Up to increase the value.
AUTO color dimmer
rb01---rb16
Value 01--16: dimmer speed, press Down/Up to change the speed.
AUTO color Pulse (ON/OFF simultaneously)
PLO1---PL16
Value 01--16: pulse speed, press Down/Up to change the speed.
Sd01-—sd16 AUTO color Jumping
Value 01--16: jumping speed, press Down/Up to change the speed.
AUTO Strobe
FLO1---FL16 [01--16 means strobe speed level, press Down/UP to increase or decrease the
value, then press Enter to save the selection.
Sod1 Sound Active color Jumping
Sod2 Sound Active color strobe, No sound the light is blackout
Sod3 Sound Active color dimmer
r000~255 |Manual set the Red LED brightness
G000~255 |Manual set the green LED brightness
b000~255 |Manual set the Blue LED brightness
d3ch Under DMX512 mode, it's 3 Channels
Press DOWN/UP to change mode
d7ch Under DMX512 mode, it's 7 Channels
Sound Active
The change of the light pattern is controlled by sound, that is, the rhythm of the sound
control the effect of the changing light pattern. Turning the sensitivity knob in the
clockwise direction to increase the fixture’s sensitivity to sound, the knob in the counter
Page 5
clockwise direction to decrease. The light diode will automatically turn off after 8
seconds when the music stops.
AUTO
Auto cycles the built-in programs without being controlled externally. It has no light OFF.
The mode allows a single unit to react to the beat of the music in the master mode.
1. Install the units in a suitable position (laying or appending).
2. Set dipswitch to select Sound Active or AUTO mode.
3. Turn on the unit power, the unit begins reset, then the unit begins working.
4. The unit will react to the low frequencies of music via the internal microphone.
Adjust the audio sensitivity knob on the back of the unit to make the unit more or less
sensitive in sound active. The panel has LED indicating for sound active.
Master-Slave Operation
This mode will allow you to link up to 32 units together without controller.
1. Install the units in a suitable position (laying or appending).
2. Choose a unit to function as Master mode, set dipswitch to select Sound Active or
AUTO mode. The others must be set to Slave mode, set dipswitch to select Slave mode.
3. Use standard XLR microphone cable chain your units together via the XLR connector
on the rear of the units. For longer cable runs we suggest a terminator at the last fixture.
Cabling must have a male XLR connector on one end and a female XLR connector on the other end.
Cable Connectors
Cabling must have a male XLR connector on one end and a female XLR connector on the other end.
Resistance 120 ÓN
ohm 1:4w between
©
з ® pin 2 (DMX -) and
O / pin 3 (DMX +) of
COMMON
DMX + (0: ой
3 @) || ОЧТРИТ
ve Termination reduces signal errors, To
the last fixture.
INPUT
DMX - avoid signal transmission problems
= and interference, it Is always
advisable to connect a DMX signal
terminator.
Caution: Do not allow contact between the common and the fixture’s chassis ground. Grounding
Page 6
the common can cause a ground loop, and your fixture may perform erratically. Test cables with
an ohm meter to verify correct polarity and to make sure the pins are not grounded or shorted
to the shield or each other.
4. Turn on the all units' power, the units begins reset, then the unit begins working. The slave
units will react the same as the master unit.
5. The units will react to the low frequencies of music via the internal microphone. Adjust the
audio sensitivity knob on the back of the master unit to make the unit more or less sensitive in
sound active. The panel has LED indicating for sound active.
Universal DMX Operation (DMX mode)
This mode allows you to use universal DMX-512 console to operate.
1. Install the units in a suitable position (laying or appending).
2. Use standard XLR microphone cable chain your units together via the XLR connector
on the rear of the units. For longer cable runs we suggest a terminator at the last fixture.
3. Assign a DMX address to each the unit using dipswitches, see the "DMX Address
Quick Reference Char".
; ; ; Light No ....
Light No 1 Light No 2 |— Light No 3 в
a - e ‚ taie A o.
Drm Gime, O Ob
у \ y 7 x > A
Ca © ) (X)
| e e — € ed Ne
7-4 44 — >
DMX Signal
1: MASTER: SOUND/AUTO/DMX 2: SLAVE 2: SLAVE
4. Turn on the all units' power, the units begins reset, then the unit begins working.
5. Use DMX console to control your units.
Notes:
1. DMX console can not be used in Master-Slave operation (Sound Active or AUTO mode ).
2. There should be only one master unit in Master-Slave operation.
DMX Control
The system only accepts the DMX512 signal of international standard to control the
system mode, the light beam ON /OFF, running direction, running speed and twinkle
speed etc.
Page 7
DMX Control:
The LED light only accepts the DMX512 signal of international standard to control the light.
DMX Control Parameter Chart
4 Channels
Channel Function Value Description
CHI 0~255 |Red brightness, dark to bright
CH2 Brightness 0~255 |Green brightness, dark to bright
CH3 0~255 |Blue brightness, dark to bright
9 Channels
Channel Function Value Description
CHI Brightness 0~255 |RGB brightness, dark to bright
CH2 0~255 |Red brightness, dark to bright
| CH3 Brightness 0~255 |Green brightness, dark to bright
CH 0~255 |Blue brightness, dark to bright
0~63 [No strobe
CHS Strobe 64~249 |AUTO strobe, speed slow to fast
250~255 |Sound Active strobe
0~10 |CHI--CHS working
11-60 |Manually select static color, controlled under CH7
sin Colartanse 61-110 |AUTO color dimmer, controlled under CH7
111~160 |AUTO color pulse, controlled under CH7
161~210 |AUTO color Jumping, controlled under CH7
211-255 |Sound Active color jumping
CH7 Speed 0~255 |Static color selection or speed control, slow to fast
Page 8
check the power supply, the input voltage and the fuse.
2. In Stand-Alone operation, if the power supply indicator is light up and sound
active indicator isn't light up, but the light is shut off doesn't work.
A. Because sound is too small make for light shut off in sound active, please
increase the music volume or increase audio sensitivity with sensitivity knob,
please check as below.
B. Please check if unit has been set up in slave mode, then set up in master mode.
3. In Master-Slave operation, slave unit don't function, please check as below.
A. Make sure to there's only one master in the chain, and the others are set in slave mode.
B. Make sure to control the unit without DMX console controlling.
C. Make sure to take a good quality power cable and connection.
4. In DMX mode operation, the light is OFF and the DMX signal indicator is
unlighted, please check as below.
A. Make sure to set up the DMX mode.
B. Make sure to have a good connection.
5. In DMX operation, the unit can’t be controlled by the DMX console, but the DMX signal
indicator 1s flashing, please make sure the DMX console and unit have the same channel.
6. If the unit is fail, please turn off the unit, then turn on again after 5 minutes.
Warranty Warnings:
|. Damages caused by the disregard of this user manual are not subject to Warranty.
The dealer will not accept liability for any resulting defects or problems.
2. Please consider that unauthorized modifications on the device are forbidden due to
safety reasons. Please note that damages caused by manual modifications on the
device or unauthorized operation by unqualified persons are not subject to warranty.
3. If this device will be operated in any way different to the one described in this
manual, it may suffer damages and the guarantee becomes void. Eurthermore, any
other operation may lead to dangers like short-circuit, burns electric shock, etc.
After trying the above solution you still have a problem, please contact your dealer
or our company for service.
Page 9

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement