Continental Hydraulics CEM-AA-B Installation Manual
Continental Hydraulics CEM-AA-B is a configurable power amplifier capable of driving either single or dual solenoids, or two independent proportional valve coils up to 2.6A. A wide range of analog or digital signals are accepted dependent on the configuration. With three selectable function modes, you can adapt this module to a variety of system requirements. Independent Ramp of acceleration and deceleration, IMIN and IMAX, PWM, DITHER settings are programmable. Additionally, the valve characteristics can be linearized via 10 X-Y points per solenoid output.
Advertisement
Advertisement
Continental Hydraulics Installation Manual
CEM-AA-B
Description:
This adaptable power amplifier is configurable to drive either single or dual solenoid, or two independent proportional valve coils up to 2.6A. A wide range of analog or digital signals are accepted dependent on the configuration. User may select either voltage, current or digital input mode. These inputs are easily scaled to match system requirements.
The CEM-AA-B module has three selectable function modes:
Function mode AA for operating one single or dual solenoid Proportional Control Valve
Function mode A-B for operating independently two single solenoid Proportional Control
Valves
Function mode RA , This mode accepts 3 independent switch inputs, each which has independently adjustable speed and ramp controls. Inputs are additive, for up to 8 unique preset speed and ramp profiles.
Independent Ramp of acceleration and deceleration, IMIN and IMAX, PWM, DITHER settings are programmable. In addition the valve characteristics can also be linearized via 10 X-Y points per solenoid output.
The module is disabled if the coil outputs are shorted or open. If command current signal is outside of the proper range, the module is disabled.
This module is easily adapted to a variety of system requirements. All variables are user adjusted with easy to use CHI-PC software on your Microsoft Windows laptop. Control variables are stored in non-volatile memory internal to the module. All variables can be read by the laptop, and reproduced exactly on other modules.
Page 1 of 33 CEM-AA-B CHI 1020611 01/2016
Continental Hydraulics Installation Manual
Table of Contents
Information Description Page #
Technical Data - All Function Modes for CEM-AA-B …………………….………..…………… 3
LED Indications - All Function Modes …………………………………………………………… 4
Steps to install and configure a new application ……………………….………………………. 5
Module Mounting Location ………………………………………….…………………………….. 6
Power Supply ………………………………………………………………………………….…… 6
Wiring to Valve …………………………………………………………………………………….. 6
Dimensions …………………………………………….…………………………………………… 6
Circuit Diagram Function AA …………………………………………………………………... 7
Terminal Identification AA Function …………………………………………………………….. 8
Parameter List
Function AA …………………………………………….………………….… 9
Circuit Diagram Function A-
B …………………………………………………………………… 10
Terminal Identification AB Function …………………………………………………………….. 11
Parameter List Function A-
B ………………………………………………….……………… 12
Circuit Diagram Function RA …………………………………………………………………… 13
Terminal Identification RA Function …………………………………………………………….. 14
Parameter List Function RA ……………………………………………………….…………… 15
Command Parameter Descriptions
FUNCTION……………………………………………………………………………..… 16
LG (Language)…………………………………………………………………………… 16
MODE……………………………………………………………………………………... 16
SENS ……………………..……………………………………………………. ………... 17
CCMODE………………………………………………………………………………… 17
SOLENOID
S……………………………………………………………………………... 17
PIN:6………………………………………………………………………………………. 18
USCALE………………………………………………………………………………….. 18
ENABLE_B……………………………………………………………………………….. 18
LIM………………………………………………………………………………………… 19
POL……………………………………………………………………………………….. 20
AINA / AINB………………………………………………………………………………. 20
AIN…………………………………………………………………………………………. 21
AA:I / AB:I (RAMP Time)
…………………………………………..………………….... 22
RMODE…………………………………………………………………………………… 23
S:0 – S:7………………………………………………………………………………….. 23
RA:0
– RA:7………………………………………………………………………………. 24
CCA / CCB……………………………………………………………………………..… 25
CC (Characteristics Lineari zation)…………………………………………………….. 26
MIN………………………………………………………………………………………... 27
MAX……………………………………………………………………………………... 27
TRIGGER………………………………………………………………………………... 27
CURRENT
……………………………………………………………………………….. 29
DFREQ…………………………………………………………………………………… 29
DAMPL…………………………………………………………………………………… 29
PWM……………………………………………………………………………………… 30
ACC………………………………………………………………………………………. 30
PPWM / IPWM …………………………………………………………………………… 31
PROCESS DATA (Monitori ng)…………………………………………………………………… 32
Failure Monitoring………………………………………………………………………………….. 33
Troubleshooting…………………………………………………………………………………….. 33
Page 2 of 33 CEM-AA-B CHI 1020611 01/2016
Continental Hydraulics Installation Manual
Technical Data - All Function Modes:
Power supply [VDC] 12… 30 (incl. ripple)
Power consumption max.
External fuse
[W]
60 (depending on type of solenoid, two solenoids are active)
[A] 3 medium time lag
Reference voltage
Digital inputs
Digital outputs
Analogue inputs
Input resistance
Resolution
Nominal PWM output current
PWM frequency
Sample time (process control)
Sample time (solenoid current control)
[V] 8 (maximum 25 mA)
[V] logic 0: < 2
[V] logic 1: > 10
[kΩ] 25
[V] logic 0: < 2
[V] logic 1: > 12 (50 mA)
[V]
±10 / 0… 10; 90 kΩ
[mA] 4...20; 390 Ω
[%] < 0.01
[mA]
500… 2600; broken wire monitored and short circuit proof.
[Hz] 61...2604; adjustable in steps
[ms] 1
[ms] 0.125
Interface
Housing
Weight
Protection class
Temperature range
Storage temperature
Humidity
Vibration
Connections
EMC
USB type B
Virtual COM port driver (CHI-PC):
9600… 57600 Baud (Default = 57600),
1 Stop bit, No parity, No handshake
Snap On Module EN 50022
Polyamide PA 6.6
Combustibility class V0 (UL94)
[kg] 0.190
IP20
[°C] 20… 60
[°C] 20 …70
[%] <95 (not condensing)
- IEC 60068-2-6 (category C)
USB type B
4 x 4 pol. screw terminals
PE: direct via DIN rail
EN 61000-6-2: 8/2005
EN 61000-6-4: 6/2007 ; A1:2011
Page 3 of 33 CEM-AA-B CHI 1020611 01/2016
Continental Hydraulics Installation Manual
LED Indications - All Function Modes:
LED's
GREEN + YELLOW
Description of the LED function
1. Chasing light (over all LEDs): The bootloader is active.
No normal functions are possible.
Yellow + Yellow
GREEN
2. All LEDs flash shortly every 6 s: An internal data error was detected and corrected automatically! The module still works regularly. To acknowledge the error the module has to have power cycled.
Both yellow LEDs flash oppositely every 1 s: The nonvolatile stored parameters are inconsistent! To acknowledge the error the data has to be saved with the SAVE command or the corresponding Function button in the CHI-PC program. If one of the FUNCTION parameter is changed to an incorrect value, that parameter value is deleted purposely, and set to default values. In this case the LEDs indicate no error.
Identical to the READY output.
OFF: No power supply or ENABLE is not activated
ON: System is ready for operation
YELLOW
Flashing: Error detected (e. g. valve solenoid or 4… 20 mA).
Not active when SENS = OFF.
LED in the middle position = Current, Channel A; the intensity is proportional to the output current
LED in the right position = Current, Channel B; the intensity is proportional to the output current
Page 4 of 33 CEM-AA-B CHI 1020611 01/2016
Continental Hydraulics Installation Manual
Steps to install and configure a new application:
All parameters are adjusted using VEA-BUSB programming cable and CHI-PC Microsoft
Windows application.
1. Mount the module in a suitable location
2. Connect the power supply and valve solenoids
3. Down load and open the GUI program ( www.continentalhydraulics.com/wpcontent/uploads/2015/01/setup-CEWMPC-10-v3.5.0.zip
)
4. Connect to Laptop via USB to USB Type B communication cable.
5. Open the Options Tab and in setting, verify that the correct com port, full-Duplex and
57.6K Baud rates are selected.
6. Select Desired Function (AA / A-B / RA) for your application as desired, Click the ID button to update the Parameter list.
7. Adjust current range to match valve
8. Adjust PWM / Dither to optimize performance of the valve
9. Adjust analog input to voltage or current, and scale input if required.
10. Adjust ramping (if desired)
11. Adjust internal monitor functions (if desired)
12. Adjust current output to the valve for the flow / pressure required (if desired)
Page 5 of 33 CEM-AA-B CHI 1020611 01/2016
Continental Hydraulics Installation Manual
Module Mounting Location:
This module is to be mounted in a cabinet for protection from the local environment.
Ensure there is adequate free space around the module to allow for cooling air flow.
This module is designed to snap onto an industry standard 35mm DIN rail.
Do not mount near other modules that emit high power electrical interference, such as motor controllers and high power contactors.
Power Supply:
This module is designed to operate on DC power from a regulated power supply ranging from 12 to 30 volts. Match valve solenoid voltage rating to power supply, typically 12 or 24 volts.
A 3 amp medium action fuse is recommended in the “+” power supply line.
Wiring to Valve:
Two conductors are required for each solenoid. There is no need for shielding on these power conductors.
Wire size is chosen to provide an acceptable voltage drop between the module and the valve solenoid. The following chart is based on 5% drop for 12v and 24v applications. The listed cable length is distance from module to valve, and includes the voltage drop of the return conductor.
Wire size 2.6A 12v 1.6A 24v 0.86A 24v
12 gauge
14 gauge
16 gauge
18 gauge
20 gauge
22 gauge
66 ft max
49 ft max
31 ft max
19 ft max
13 ft max
8 ft max
215 ft max
159 ft max
100 ft max
63 ft max
39 ft max
25 ft max
400 ft max
295 ft max
186 ft max
117 ft max
73 ft max
46 ft max
Dimensions:
3.9" 0.9"
Page 6 of 33 CEM-AA-B
4.5"
CHI 1020611 01/2016
Continental Hydraulics Installation Manual
Circuit Diagram Function AA
Page 7 of 33 CEM-AA-B CHI 1020611 01/2016
Continental Hydraulics Installation Manual
CEM-AA-B Function AA Input and Output Terminals
Connection
PIN 7
PIN 8
Connection
PIN 12
Connection
PIN 3 / 4
PIN 1 / 2
Connection
PIN 9 / 10
PIN 11
Connection
PIN 15
PIN 6
PIN 5
Supply
Power supply (see technical data)
0 V (GND) Power supply (ground).
Attention , PIN 8 and PIN 11 are connected internally. PIN 11 is used as the GND potential for the command and feedback signals..
Reference voltages output
Reference output voltage (8 V).
PWM output
Current controlled PWM outputs for solenoid A.
Current controlled PWM outputs for solenoid B.
Analogue input signals
Command (input) signal (W), range -100…100 % corresponds with -
10…10 V or 4…20 mA
0 V reference for the signal inputs.
Attention , PIN 8 and PIN 11 are connected internally
Digital inputs and outputs
Enable Input :
This digital input signal initializes the application.
The output and the READY signal will be activated.
By deactivating, error signals are reset.
S1 input:
Function depends on parameter PIN:6 (USCALE/RAMP).
OFF: Output current depends on parameter USCALE; ramp function is deactivated.
ON: Output current is not scaled by USCALE, ramp function is activated.
READY output :
ON: Module is ready, no errors are detected
OFF: ENABLE (PIN 15) is deactivated or an error is detected.
Page 8 of 33 CEM-AA-B CHI 1020611 01/2016
Continental Hydraulics Installation Manual
Parameter List Function AA
Ref Page
Command
16 FUNCTION
16 LG
16 MODE
17 SENS
17 CCMODE
18 PIN:6
18 USCALE
19 LIM
20 POL
20 AINA
20 AIN:A
22 AA:1
22 AA:2
22 AA:3
22 AA:4
26 CC
27 MIN:A
27 MIN:B
27 MAX:A
27 MAX:B
27 TRIGGER
29 CURRENT
29 DAMPL
29 DFREQ
30 PWM
30 ACC
31 PPWM
31 IPWM
Parameter Help / Description
AA Function mode (AA / A-B / RA) Press ID button after selection
EN EN English
EXP Standard / Expert mode
AUTO Malfunction monitoring [ON / OFF /AUTO]
OFF Characteristics linearization [ON / OFF]
USCALE Function of PIN 6 [USCALE / RAMP]
10000 Output current scale in 0.01%
0 Range control input signal in 0.01%
+ Output polarity (+/-)
V Input switching, voltage or current [V/C] (Voltage default)
1000 1000 0 V Input scaling via linear equation
100 Ramptime acceleration A in ms
100 Ramptime deceleration A in ms
100 Ramptime acceleration B in ms
100 Ramptime deceleration B in ms characteristic curve Free definable characteristic linearization
0 Compensation of the Deadband in 0.01%
0 Compensation of the Deadband in 0.01%
10000 Output Scaling in 0.01%
10000 Output Scaling in 0.01%
200 Trigger point of the MIN function in 0.01%
1000 Rated solenoid current 500…. 2600 mA
500 Dither amplitude in 0.01% of rated current
121 Dither frequency in Hz
2604 PWM frequency in Hz
ON Auto Adjustment of the current loop [OFF / ON]
7 P-Gain of the current loop
40 I-Gain of the current loop
X
X
X
X
X
X
X
X
X
X
X
X
MODE
STD EXP
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Page 9 of 33 CEM-AA-B CHI 1020611 01/2016
Continental Hydraulics Installation Manual
Circuit Diagram Function A-B
Page 10 of 33 CEM-AA-B CHI 1020611 01/2016
Continental Hydraulics Installation Manual
CEM-AA-B Function A-B Input and Output Terminals
Connection
PIN 7
PIN 8
Connection
PIN 12
Connection
PIN 3 / 4
PIN 1 / 2
Connection
PIN 9 / 10
PIN 13 / 14
PIN 11
Connection
PIN 15
PIN 6
PIN 5
Supply
Power supply (see technical data)
0 V (GND) Power supply (ground).
Attention , PIN 8 and PIN 11 are connected internally. PIN 11 is used as the GND potential for the command and feedback signals.
Reference voltages output
Reference output voltage (8 V)
PWM output
Current controlled PWM outputs for solenoid A
Current controlled PWM outputs for solenoid B
Analogue input signals
Command (input) signal A, range 0…100 % corresponds with 0…10 V or 4…20 mA
Command (input) signal B, range 0…100 % corresponds with 0…10 V or 4…20 mA
0 V reference for the signal inputs.
Attention , PIN 8 and PIN 11 are connected internally
Digital inputs and outputs
Enable Input Channel A/B or Channel A (dependent on ENABLE_B) :
This digital input signal initializes the application.
The output and the READY signal will be activated.
By deactivating error signals are reset.
Enable Input Channel B (dependent on ENABLE_B) :
This digital input signal initializes the application.
The output and the READY signal will be activated.
By deactivating error signals are reset.
READY output :
ON: No internal or external errors are detected.
OFF: Both power stages are deactivated or an error is detected.
Page 11 of 33 CEM-AA-B CHI 1020611 01/2016
Continental Hydraulics Installation Manual
Parameter List Function A-B
Ref Page
Command
16 FUNCTION
16 LG
16 MODE
17 SENS
17 CCMODE
18 ENABLE-B
19 LIM:A
19 LIM:B
20 POL:A
20 POL:B
20 AINA
22 AINB
21 AIN:A
21 AIN:B
22 AA:UP
22 AA:DOWN
22 AB:UP
22 AB:DOWN
25 CCA
25 CCB
27 MIN:A
27 MIN:B
27 MAX:A
27 MAX:B
27 TRIGGER
29 CURRENT:A
29 CURRENT:B
29 DAMPL:A
29 DAMPL:B
29 DFREQ:A
29 DFREQ:B
30 PWM:A
30 PWM:B
30 ACC
31 PPWM:A
31 PPWM:B
31 IPWM:A
31 IPWM:B
Parameter Help / Description
A-B Function mode (AA / A-B / RA) Press ID button after selection
EN EN English
EXP Standard / Expert mode
AUTO Malfunction monitoring [ON / OFF /AUTO]
OFF Characteristics linearization [ON / OFF]
OFF Separate enable signals [OFF / ON]
0 Range control input signal in 0.01%
0 Range control input signal in 0.01%
0 Output polarity (+/-)
+ Output polarity (+/-)
V Input switching, voltage or current [V/C] (Voltage default)
V Input switching, voltage or current [V/C] (Voltage default)
1000 1000 0 V Input scaling via linear equation
1000 1000 0 V Input scaling via linear equation
100 Ramptime acceleration A in ms
100 Ramptime deceleration A in ms
100 Ramptime acceleration B in ms
100 Ramptime deceleration B in ms characteristic curve Free definable characteristic linearization characteristic curve Free definable characteristic linearization
0 Compensation of the Deadband in 0.01%
0 Compensation of the Deadband in 0.01%
10000 Output Scaling in 0.01%
10000 Output Scaling in 0.01%
200 Trigger point of the MIN function in 0.01%
1000 Rated solenoid current 500…. 2600 mA
1000 Rated solenoid current 500…. 2600 mA
500 Dither amplitude in 0.01% of rated current
500 Dither amplitude in 0.01% of rated current
121 Dither frequency in Hz
121 Dither frequency in Hz
2604 PWM frequency in Hz
2604 PWM frequency in Hz
ON Auto Adjustment of the current loop [OFF / ON]
7 P-Gain of the current loop
7 P-Gain of the current loop
40 I-Gain of the current loop
40 I-Gain of the current loop
X
X
X
X
X
X
X
X
MODE
STD EXP
X
X
X
X
X x
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Page 12 of 33 CEM-AA-B CHI 1020611 01/2016
Continental Hydraulics Installation Manual
Circuit Diagram Function RA
Page 13 of 33 CEM-AA-B CHI 1020611 01/2016
Continental Hydraulics Installation Manual
CEM-AA-B Function RA Input and Output Terminals
Connection
PIN 7
PIN 8
Connection
PIN 12
Connection
PIN 3 / 4
PIN 1 / 2
Connection
PIN 6 / 9 / 14
PIN 11
Connection
PIN 15
Supply
Power supply (see technical data)
0 V (GND) Power supply (ground).
Attention , PIN 8 and PIN 11 are connected internally. PIN 11 is used as the GND potential for the command and feedback signals.
Reference voltages output
Reference output voltage (8 V).
PWM output
Current controlled PWM outputs for solenoid A
Current controlled PWM outputs for solenoid B.
Analogue input signals
Digital gate inputs for selecting the command value:
PIN 6: S1 PIN 9: S2 PIN 14: S4
The whole range of set points can be chosen by binary coding of these inputs.
0 V reference for the signal inputs.
Attention , PIN 8 and PIN 11 are connected internally.
Digital inputs and outputs
Enable Input :
This digital input signal initializes the application.
The output and the READY signal will be activated.
By deactivating error signals are reset.
PIN 5
READY output :
ON: No internal or external errors are detected
OFF: ENABLE (PIN 15) is deactivated or an error is detected
Page 14 of 33 CEM-AA-B CHI 1020611 01/2016
Continental Hydraulics Installation Manual
Parameter List Function RA
Ref Page
Command
16 FUNCTION
16 LG
16 MODE
17 SENS
17 SOLENOIDS
23 RMODE
23 S:0
23 S:1
23 S:2
23 S:3
23 S:4
23 S:5
23 S:6
23 S:7
24 RA:0
24 RA:1
24 RA:2
24 RA:3
24 RA:4
24 RA:5
24 RA:6
24 RA:7
22 AA:1
22 AA:2
22 AA:3
22 AA:4
26 CC
27 MIN:A
27 MIN:B
27 MAX:A
27 MAX:B
27 TRIGGER
29 CURRENT
29 DAMPL
29 DFREQ
30 PWM
30 ACC
31 PPWM
31 IPWM
Parameter Help / Description
RA Function mode (AA / A-B / RA) Press ID button after selection X
EN EN English X
EXP Standard / Expert mode
AUTO Malfunction monitoring [ON / OFF /AUTO]
X
X
2 Number of Solenoids
SD Rampmode SD or 4Q
0 Demand value related to the digital inputs in 0.01%
0 Demand value related to the digital inputs in 0.01%
X
X
X
X
0 Demand value related to the digital inputs in 0.01%
0 Demand value related to the digital inputs in 0.01%
0 Demand value related to the digital inputs in 0.01%
0 Demand value related to the digital inputs in 0.01%
0 Demand value related to the digital inputs in 0.01%
0 Demand value related to the digital inputs in 0.01%
100 Ramptime related to the digital inputs in ms
100 Ramptime related to the digital inputs in ms
100 Ramptime related to the digital inputs in ms
100 Ramptime related to the digital inputs in ms
100 Ramptime related to the digital inputs in ms
100 Ramptime related to the digital inputs in ms
X
X
X
X
X
X
X
X
X
X
X
X
100 Ramptime related to the digital inputs in ms
100 Ramptime related to the digital inputs in ms
100 Ramptime acceleration A in ms
100 Ramptime deceleration A in ms
100 Ramptime acceleration B in ms
100 Ramptime deceleration B in ms characteristic curve Free definable characteristic linearization
0 Compensation of the Deadband in 0.01%
0 Compensation of the Deadband in 0.01%
10000 Output Scaling in 0.01%
10000 Output Scaling in 0.01%
200 Trigger point of the MIN function in 0.01%
1000 Rated solenoid current 500…. 2600 mA
500 Dither amplitude in 0.01% of rated current
121 Dither frequency in Hz
2604 PWM frequency in Hz
ON Auto Adjustment of the current loop [OFF / ON]
7 P-Gain of the current loop
40 I-Gain of the current loop
X
X
X
X
X
X
X
X
X
X
MODE
STD EXP-SD EXP-4Q
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Page 15 of 33 CEM-AA-B CHI 1020611 01/2016
Continental Hydraulics Installation Manual
Parameter Descriptions
FUNCTION (Function mode)
Command Parameters
FUNCTION X x= AA|A-B|RA
Unit
-
Group
STD
The general Operating function of the module will be defined by this command.
AA: Functionality for directional valves with two solenoids and analogue input signals
A-B: Functionality for two pressure/throttle valves with analogue input signals
RA: Functionality for directional, pressure and throttle valves with pre-programmed values, selectable by digital inputs.
After changing this parameter the ID-button has to be pressed in order to rebuild the parameter table and a SAVE button has to be conducted.
LG (Changing the language for the help texts)
Command
LG X
Parameters x= EN English
DE German
Unit
-
Group
STD
Either English or German can be selected for the help texts in the CHI-PC Microsoft Windows application.
After making a change to the language settings, the parameter list has to be updated by pressing the “ID” button.
MODE (Switching between parameter groups)
Command
MODE X
Parameters x= STD|EXP
Unit
-
Group
STD
This command changes the parameter mode. Various commands (defined via STD/EXP) are blanked out in standard mode. The several commands in expert mode have more significant influence on the system performance. Therefore they should be changed with care.
Page 16 of 33 CEM-AA-B CHI 1020611 01/2016
Continental Hydraulics Installation Manual
SENS (Failure monitoring)
Command
SENS X
Parameters Unit x= ON|OFF|AUTO -
Group
STD
This command is used to activate/deactivate the monitoring functions (4… 20 mA sensors, output current, signal range and internal failures) of the module.
ON: All monitoring functions are active. Detected failures can be reset by deactivating the
ENABLE input. This mode should be used in case of active enabling and monitoring by a PLC (READY signal).
OFF: No monitoring function is active.
AUTO: (Default Setting) Auto reset mode. All monitoring functions are active. If the failure does not exist anymore, the module automatically resumes to work.
Normally the monitoring functions are always active because otherwise no errors are detectable via the READY output. Deactivating is possible especially for troubleshooting.
AUTO MODE: The module checks each second the actual failure status, which will (in case of a persistent error) trigger the LED and the READY output for a short time.
CCMODE (Activation of the characteristic linearization)
Command
CCMODE
Parameters
X x= ON|OFF
Unit
-
Group
EXP
FUNCTION
AA
A-B
This command will be used for activation or deactivation of the characteristics linearization (CC,
CCA and CCB). Through activating this parameter a simple and quick estimation of the linearization is possible. ( See pages 22 – 23 for more details )
SOLENOIDS (One or two solenoids)
Command Parameters
SOLENOIDS X x= 1|2
Unit
-
Group
STD
FUNCTION
RA
This parameter allows you to adapt the amplifier to valves with one solenoid (e.g. pressure valves) or with two solenoids (directional valves).
Page 17 of 33 CEM-AA-B CHI 1020611 01/2016
Continental Hydraulics Installation Manual
PIN:6 (Choice of the additional function of S1/PIN 6)
Command
PIN:6
Parameters Unit x x= USCALE | RAMP -
Group
EXP
This parameter defines the functionality of digital input PIN:6
USCALE: PIN 6 = active, USCALE will not scale the output.
PIN 6 = inactive, the output may be scaled by the USCALE parameter.
Ramps are active.
FUNCTION
AA
RAMP: PIN 6 = active, the internal ramp generator is activated.
PIN 6 = inactive, the internal ramp generator is deactivated.
USCALE is inactive.
USCALE (Output current scaling depending on PIN:6)
Command
USCALE
Parameters Unit x x= -10000… 10000 0.01 %
Group
EXP
FUNCTION
AA
If the parameter PIN:6 is set to USCALE and the digital input S1 (PIN 6) is off, this parameter scales the output current. The default setting is 10000 (100 %) which does not change the output.
If USCALE is set to -10000 the polarity of the output will be flipped by switching the digital input
S1, which allows for controlling the module with a unipolar analogue signal.
If USCALE is set to 5000 the output of the Minimum and Maximum value will be reduced by 50% with the same input command values.
ENABLE_B (Switching of the ENABLE Function)
Command Parameters
ENABLE_B x x= ON|OFF
Unit
-
Group
EXP
FUNCTION
A-B
The setting of this parameter activates independent enable signals for channel A and B. If set to
OFF, digital input PIN 15 enables both output channels. If set to ON, digital input PIN 15 enables only channel A and digital input PIN 6 enables channel B. If only one solenoid is to be controlled,
ENABLE_B has to be set to ON and only the corresponding digital input has to be switched on.
Page 18 of 33 CEM-AA-B CHI 1020611 01/2016
Continental Hydraulics Installation Manual
LIM (Signal monitoring)
Command
LIM:I X
Parameters i= A|B x= 0… 2000 x= 0… 2000
Unit
0.01%
Group
EXP
FUNCTION
A-B
LIM X 0.01%
EXP AA
The signal monitoring deactivates the output current and the READY output if the input signal leaves the permitted range after scaling. This function makes it possible to detect a short circuit or cable break of a joystick or potentiometer.
Example: LIM 500 (5% lower/upper limitation) If the input signal gets higher than 95 % or lower than 5%, it leaves the permitted range and the outputs will switch off.
100% error range for unipolar signals working range error range for bipolar signals
-100%
Page 19 of 33 CEM-AA-B CHI 1020611 01/2016
Continental Hydraulics Installation Manual
POL (Output polarity)
Command
POL:I
Parameters
X i= A|B x= +|-
POL X x= +|-
Unit
-
Group
STD
FUNCTION
A-B
-
STD AA
Valves with one solenoid:
This command allows a switch over of the output signal direction (after the MIN-MAX function).
Example: POL:A + Input signal 0… 100 %, nominal output current 0… 100 %.
POL:A - Input signal 0… 100 % nominal output current 100… 0 %.
Directional valves:
This command allows a switch over of the output polarity.
AINA (Current- / Voltage input)
AINB (Current- / Voltage input)
Command
AINA X
AINB X
Parameters x=V|C
Unit
-
Group
STD
FUNCTION
AA
A-B
By the use of this command, the type of input signal may be chosen between voltage (0...10 V or
+/- 10 V) or current (4…20mA). If current is chosen, the shunt will be activated automatically.
AIN (Analogue input scaling)
Command Parameters
AIN:I a b c x i = A|B a= -10000… 10000 b= -10000… 10000 c= -10000… 10000 x = V|C
Unit
-
-
-
0.01%
-
Group
EXP
FUNCTION
AA
A-B
Page 20 of 33 CEM-AA-B CHI 1020611 01/2016
Continental Hydraulics Installation Manual
AIN (Analogue input scaling Continued)
This command offers an individual scalable input. The following linear equation is used for the scaling.
Output = A/B ∙ (Input – C)
The
“C” value is the offset (e.g. to compensate the 4 mA in case of a 4… 20 mA input signal).
The variables A and B are defining the gain factor with which the signal range is scaled up to
100 % (e.g. 1.25 if using 4… 20mA input signal, defined in default current settings by A = 1250 and B = 1000). The internal shunt for the current input signal is activated when parameters AIN:A and AIN:B are set to Current (X=C).
The gain factor is calculated by dividing total input signal range ( A ) by the actual input range ( B ).
In the case of a 4-20mA with a single solenoid valve, the total range is 0-20mA, which means
A=20 . The actual range is 4-20 mA, therefore, B= (20-4) =16 . An offset, C , must be added to compensate for the 0-4mA not being used of the full range. The offset is 4mA/20mA=0.2 or 20%.
Therefore C=2000 since the unit value for C is 0.01%.
Shown in the below table are the most common input command signal and the corresponding settings to be used.
Typical settings (examples):
FUNCTION = AA
A B C
AIN:I 20 20
AIN:I 1000 1000
AIN:I 20 10
AIN:I 2000 1000
0 V OR
0 V
0 V OR
0 V
Input signal
-10… 10 V
-5… 5 V
Description
Voltages input: Usable -
10… 10V (20V) for a working range of 100… 100% ( two solenoids ).
AIN:I 20 10 5000 V OR
AIN:I 2000 1000 5000 V
AIN:I 40 16 6000 C OR
AIN:I 2500 1000 6000 C
0… 10 V
4… 20 mA
Input signal
Voltages input: Usable -
10… 10V (20V) for a working range of 100… 100% ( two solenoids ).
Really used are 5… 5V (10V).
Voltages input: Usable 10… 10V (20V) for a working range of 100… 100% ( two solenoids ).
Really used are only 0… 10V for both solenoids with
5V zero point setting (e.g. for joystick use).
Current input: theoretically usable range 20… 20mA
(40mA) for a working range of -
100… 100%
( two solenoids ).
Really usable are only 4… 20mA (16mA) for both solenoids with 12mA zero point setting.
Description FUNCTION = A-B
A B C
AIN:I 10 5 0 V OR
AIN:I 2000 1000 0 V
0… 5 V
AIN:I 10 8 1000 V OR
AIN:I 1250 1000 1000 V
AIN:I 20 16 2000 C OR
AIN:I 1250 1000 2000 C
1… 9 V
4… 20 mA
Voltages input: Usable 0… 10V for a working range of
0… 100% ( one solenoid ).
Really used are 0… 5V for 0… 100%.
Voltages input: Usable 0… 10V for a working range of
0… 100% ( one solenoid ).
Really used are 1… 9V (8V) for 100% with 10% offset.
Current input: theoretically usable range 0… 20mA for a working range of 0… 100% ( one solenoids ).
Really usable are 4… 20mA (16mA).
Page 21 of 33 CEM-AA-B CHI 1020611 01/2016
Continental Hydraulics Installation Manual
AA and AB (Ramp function/Acceleration time)
Commando
AA:I X
AB:I X
Parameters i= UP|DOWN x= 1… 120000 x= 1… 120000
Unit ms ms
Group
STD
FUNCTION
A-B
Two quadrant ramp function.
The first quadrant means the ramp up and the second quadrant means the ramp down time. The ramp time is related to 100 % signal step.
AA:UP
AB:UP
AA:DOWN
AB:DOWN t
AA (Ramp function)
Command
AA:I X
Parameters i= 1… 4 x= 1… 120000
Unit
- ms
Group
STD
FUNCTION
AA
RA
– 4Q Mode
Four quadrants ramp function.
The first quadrant means the acceleration ramp for solenoid A and the second one stands for the deceleration ramp of solenoid A. According to this the third quadrant represents the acceleration ramp for solenoid B so that the fourth quadrant remains for the deceleration ramp for solenoid B.
AA:1 AA:2
AA:3 AA:4 t
Page 22 of 33 CEM-AA-B CHI 1020611 01/2016
Continental Hydraulics Installation Manual
RMODE (Choosing ramp function)
Command
RMODE X
Parameters x= SD|4Q
Unit
-
Group
STD
FUNCTION
RA
Choosing the ramp function.
This command allows the switching between a set point related ramp function (SD), which makes it possible to assign an individual ramp time for each command value, and a four quadrant ramp function (4Q) with set point independent ramp times for acceleration and deceleration in both directions.
S
:0 …. S:7 (Presetting command values)
Command
S:I
Parameters
X i= 0… 7 x= -10000… 10000
Unit
0.01%
Group
STD/EXP
FUNCTION
RA:
SD and 4Q Mode
With this parameter eight possible command values can be set. The binary value of the three digital inputs S1, S2 and S4 determines the set point.
Setpoint > S:0 S:1 S:2 S:3 S:4 S:5 S:6 S:7
Input S1
Input S2
Input S4
0
0
0
1
0
0
0
1
0
1
1
0
0
0
1
1
0
1
0
1
1
1
1
1
Page 23 of 33 CEM-AA-B CHI 1020611 01/2016
Continental Hydraulics Installation Manual
RA
:0 … RA:7 (Ramp function / Acceleration time)
Command
RA:I X
Parameters i= 0… 7 x= 1… 120000
Unit
- ms
Group
STD
FUNCTION
RA – SD Mode
Presetting of the ramp times. Functionality depends on command RMODE.
RMODE = SD: In this mode every command value has its own ramp time.
For example: if you choose set point S:1 also ramp time RA:1 is chosen.
RMODE = 4Q Four quadrants ramp function. See command AA (page 19)
S:1 and RA:1
S:2 and RA:2
S:3 and RA:3
S:4 and RA:4 t
Page 24 of 33 CEM-AA-B CHI 1020611 01/2016
Continental Hydraulics Installation Manual
CCA (Characteristics linearization channel A)
CCB (Characteristics linearization channel B)
Command
CCA:I
CCB:I
X Y
X Y
Parameters i= 0… 10 x= -10000… 10000 y= -10000… 10000
Unit
-
0.01 %
0.01 %
Group
CCMODE=ON
FUNCTION
A-B
A user defined signal characteristic can be set by this function. For activating the parameter
CCMODE has to be switched to ON.
In case of using single solenoid valves, only the first quadrant is active. The curve is calculated according to the equation of the linear interpolation y=(x-x1)*(y1-y0)/(x1-x0)+y1 .
The influence of the linearization can be estimated via the process data on the monitor or on the oscilloscope.
For the input of the characteristics linearization, the CHI-PC program provides a table and a graphic data input. The input signal is mapped on to the X-axis and the output signal is mapped on to the Y-axis.
Page 25 of 33 CEM-AA-B CHI 1020611 01/2016
Continental Hydraulics Installation Manual
CC (Characteristics linearization)
Command
CC:I X Y
Parameters i= -10… 10 x= -10000… 10000 y= -10000… 10000
Unit
-
0.01%
0.01%
Group
CCMODE=ON
FUNCTION
AA
A-B
A user defined signal characteristic can be set by this function. For activating the parameter
CCMODE has to be switched to ON.
The positive indexes stand for the solenoid A, the negative ones represent the solenoid B. The curve is calculated according to the equation of the linear interpolation: y=(x-x1)*(y1-y0)/(x1x0)+y1 .
The influence of the linearization can be estimated via the process data on the monitor or on the oscilloscope.
For the input of the characteristics linearization, the CHI-PC program provides a table and a graphic data input. The input signal is mapped on to the X-axis and the output signal is mapped on to the Y-axis.
Page 26 of 33 CEM-AA-B CHI 1020611 01/2016
Continental Hydraulics Installation Manual
MIN (Overlap compensation)
MAX (output scaling)
TRIGGER (threshold value of MIN function)
Command
MIN:I
MAX:I
X
X
TRIGGER X
Parameters i= A|B x= 0… 6000 x= 5000… 10000 x= 0… 3000
Unit
-
0.01 %
0.01 %
0.01 %
Group
STD
FUNCTION
A-B
The output signal is adapted to the valve by these commands. With the MAX value the output signal (the maximum valve current) will be defined. With the MIN value the overlap (dead band of the valve) will be compensated. Via the TRIGGER command the activation point of the MIN function is set and so a non-sensitive range around the zero-point 1 can be specified.
CAUTION : If the MIN value is set too high, it influences the minimal velocity, which cannot be adjusted any longer.
10V
MAX
MIN
100%
Eingang / Input
TRIGGER
1 This dead band is necessary, in order to avoid unrequested activations caused by small variations of the input signal.
Page 27 of 33 CEM-AA-B CHI 1020611 01/2016
Command
MIN:I
MAX:I
X
X
TRIGGER X
Continental Hydraulics Installation Manual
Parameters i= A|B x= 0… 6000 x= 5000… 10000 x= 0… 3000
Unit
-
0.01%
0.01%
0.01%
Group
STD
FUNCTION
AA
RA
The output signal is adapted to the valve by these commands. The output signal (the maximum valve current) is defined by the MAX:I value. The overlap (dead band of the valve) is compensated by the MIN:I value. The activation of the MIN function is set with the TRIGGER . No output can occur when the command is below the TRIGGER point. The TRIGGER is used to avoid unrequested activation caused by small variations of the input signal. When using this module as part of a closed position loop the trigger value should be reduced.
MAX:A
TRIGGER
Input
MIN:A
MIN:B
MAX:B
Page 28 of 33 CEM-AA-B CHI 1020611 01/2016
Continental Hydraulics Installation Manual
CURRENT (Nominal output current)
Command Parameters
CURRENT:I X i= A|B x= 500… 2600
CURRENT X x= 500… 2600
Unit mA mA
Group
STD
FUNCTION
A-B
STD AA
RA
The nominal solenoid current is set with this parameter. The DITHER and also the MIN/MAX parameter always refer to the selected current range.
DFREQ (Dither frequency)
DAMPL (Dither amplitude)
Command
DAMPL:I X
DFREQ:I X
DAMPL X
DFREQ X
Parameters i= A|B x= 0… 3000 x= 60… 400 x= 0… 3000 x= 60… 400
Unit
0.01 %
Hz
0.01 %
Hz
Group
STD
FUNCTION
A-B
STD AA
RA
The dither 2 can be defined freely with this command. Different amplitudes or frequencies may be required depending on the respective valve. The dither amplitude is defined in % of the nominal current (see: CURRENT command).
CAUTION: The PPWM and IPWM parameters influence the effect of the dither setting. These parameters should not be changed again after the dither has been optimized.
CAUTION : If the PWM frequency is less than 500 Hz, the dither amplitude should be set to zero .
2 The DITHER is a superimposed signal to reduce the hysteresis. This function is defined by the amplitude and frequency. The DITHER frequency should not be confused with the PWM frequency. In some proportional valve documentations a mistake is done by the definition of the DITHER / PWM frequency. It is recognizable by missing information about the DITHER amplitude.
Page 29 of 33 CEM-AA-B CHI 1020611 01/2016
Continental Hydraulics Installation Manual
PWM (PWM frequency)
Command
PWM:I X
PWM X
Parameters i= A|B x= 61… 2604 x= 61… 2604
Unit
Hz
Hz
Group
EXP
FUNCTION
A-B
EXP AA
RA
The frequency can be changed in the defined steps (61 Hz, 72 Hz, 85 Hz, 100 Hz, 120 Hz, 150
Hz, 200 Hz, 269 Hz, 372 Hz, 488 Hz, 624 Hz, 781 Hz, 976 Hz, 1201 Hz, 1420 Hz, 1562 Hz, 1736
Hz, 1953 Hz, 2232 Hz and 2604 Hz). The optimum frequency depends on the valve.
Attention: The PPWM and IPWM parameters should be adapted when using low PWM frequencies because of the longer dead times which forces a reduced stability of the closed loop control.
ACC (Auto adaptation of the closed loop current controller)
Command
ACC x
Parameters x= ON|OFF
Unit
-
Group
STD
FUNCTION
AA
A-B
RA
Operation mode of the closed loop current control.
ON : In automatic mode PPWM and IPWM are calculated depending on the preset PWMfrequency.
OFF : Manual adjustment.
Page 30 of 33 CEM-AA-B CHI 1020611 01/2016
Continental Hydraulics Installation Manual
PPWM (Solenoid current controller P gain)
IPWM (Solenoid current controller I gain)
Command
PPWM:I
IPWM:I
X
X
PPWM
IPWM
X
X
Parameters i= A|B x= 0… 30 x= 1… 100 x= 0… 30 x= 1… 100
Unit
-
-
-
-
-
Group
EXP
FUNCTION
A-B
EXP AA
RA
The PI current controller for the solenoids is parameterized with these commands.
CAUTION : These parameters should not be changed without adequate measurement facilities and experiences.
Attention, if the parameter ACC is set to ON, these adjustments are done automatically.
If the PWM frequency is < 250 Hz, the dynamic of the current controller has to be decreased.
Typical values are: PPWM = 1… 3 and IPWM = 40… 80.
If the PWM frequency is > 1000 Hz, the default values of PPWM = 7 and IPWM = 40 should be chosen.
Page 31 of 33 CEM-AA-B CHI 1020611 01/2016
Continental Hydraulics Installation Manual
PROCESS DATA (Monitoring)
Command
W
C
U
IA
IB
Description
Command value after input scaling
Command value after linearization
Command value to current controller
Output current of solenoid A
Output current of solenoid B
Description
Unit
%
%
% mA mA
Unit
FUNCTION
AA
Command
WA
CA
UA
WB
CB
UB
IA
IB
Command value after input scaling channel A
Command value after linearization channel A
Command value to current controller channel A
Command value after input scaling channel B
Command value after linearization channel B
Command value to current controller channel B
Output current of solenoid A
Output current of solenoid B
Description
%
%
%
%
%
% mA mA
Unit
FUNCTION
A-B
Command
W
C
U
IA
IB
Chosen command value
Command value after ramp function
Command value to current controller
Output current of solenoid A
Output current of solenoid B
%
%
% mA mA
FUNCTION
RA
The process data are the variable values which can be continuously observed on the monitor or on the oscilloscope.
Page 32 of 33 CEM-AA-B CHI 1020611 01/2016
Continental Hydraulics Installation Manual
Failure monitoring
Following possible error sources are monitored continuously when SENS = ON / AUTO:
Source
Command signal PIN 9 / 10 or
Command signal PIN 14 / 13, 4...20mA
Fault
Out of range
Command signal PIN 9 / 10 or
Command signal PIN 14 / 13, LIM function
Out of range
Solenoid A PIN 3 / 4
Solenoid B PIN 1 / 2
EEPROM
(monitored during power on procedure)
Broken wire
Data error
Characteristics
The power stage is deactivated.
The power stage is deactivated.
The power stage is deactivated.
The power stage is deactivated.
The module can be activated by saving new parameters
(pressing of the SAVE Button).
Troubleshooting
Initial situation is an operable status of the device and existing communication between the module and the CHI-PC program. Furthermore, the parameterization of the valve control has to be done with the assistance of the valve data sheets.
The RC mode in monitor can be used to analyze faults.
FAULT CAUSE / SOLUTION
ENABLE is active, the module does not respond, and the
READY LED is off.
ENABLE is active, the
READY LED is flashing.
Probably the power supply is disconnected or the ENABLE signal is not present.
If there is no power supply there is also no communication via our operating program. If the connection to the CHI-PC exists, the power supply is also available. In this case the availability of the ENABLE signal can be checked via the monitor.
The flashing READY LED indicates that a fault is detected by the module. The fault could be:
Failure detection in case of current input. Input signal below 3 mA.
Failure detection in case of active LIM function (for example joystick monitoring) Input signals are out of range.
A broken cable or incorrect wiring to the solenoids.
Internal data error: execute the command / press the button SAVE to delete the data error. The system reloads the DEFAULT data.
With the CHI-PC program the failure can be localized directly via the monitor.
Page 33 of 33 CEM-AA-B CHI 1020611 01/2016