CAUTION
TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER.
NO USER SERVICEABLE PARTS INSIDE.
PLEASE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
WARNING
TO PREVENT FIRE OR ELECTRIC SHOCK HAZARD, DO NOT EXPOSE THIS APPLIANCE TO
RAIN OR MOISTURE.
LIMITATIONS ON USE. THIS EQUIPMENT IS NOT INTENDED FOR USE WITH LIFE
SUPPORT EQUIPMENT OR OTHER MEDICAL EQUIPMENT OR DEVICES.
For safe and optimum performance, the Solar Power Storage System must be used
properly. Carefully read and follow all instructions and guidelines in this manual and
give special attention to the CAUTION and WARNING statements.
If you have technical problems, first contact your installer.
products or any necessary assistance, please contact us:
Service Contact Information
For more about HAMAK
LIMITATION OF LIABILITY
 THIS PUBLICATION IS PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND,
EITHER EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO, THE IMPLIED
WARRANTIES OF MERCHANTIBILITY, FITNESS FOR ANY PARTICULAR PURPOSE,
OR NON-INFRINGEMENT OF THE THIRD PARTY’S RIGHT.
 THIS
PUBLICATION
COULD
INCLUDE
TECHNICAL
INACCUACIES
OR
TYPOGRAPHICAL ERRORS. CHANGES ARE ADDED TO THE INFORMATION HEREIN,
AT ANY TIME, FOR THE IMPROVEMENTS OF THIS PUBLICATION AND/OR THE
CORRESPONDING PRODUCT(S).
DISCLAIMER OF WARRANTY
IN NO EVENT SHALL THE SUPPLIER BE LIABLBE TO ANY PARTY OR ANY PERSON,
EXCEPT FOR REPLACEMENT OR REASONABLE MAINTENANCE OF THE PRODUCT, FOR
THE CASES, INCLUDING BUT NOT LIMITED TO THE FOLLOWINGS:
 ANY DAMAGE OR LOSS, INCLUDING BUT WITHOUT LIMITATION, DIRECT OR
INDIRECT, SPECIAL, CONSEQUENTIAL OR EXEMPLARY, ARISING OUT OF OR
RELATING TO THE PRODUCT;
 PERSONAL INJURY OR ANY DAMAGE CAUSED BY INAPPROPRIATE USE OR
NEGLIGENT OPERATION OF THE USER;
 UNAUTHORIZED DISASSEMBLE, REPAIR OR MODIFICATION OF THE PRODUCT BY
THE USER;
 ANY PROBLEM, CONSEQUENTIAL INCONVENIENCE, OR LOSS OR DAMAGE,
ARISING OUT OF THE SYSTEM COMBINED WITH THE DEVICES OF THE THIRD
PARTY;
 ANY CLAIM OR ACTION FOR DAMAGES, BROUGHT BY ANY PERSON OR
ORGANIZATION BEING A PHOTOGENIC SUBJECT, DUE TO VIOLATION OF PRIVACY
WITH THE RESULT OF THAT SURVEILLANCE-CAMERA’S PICTURE, INCLUDING
SAVED DATA, FOR SOME REASON, BECOMES PUBLIC OR IS USED FOR THE
PURPOSE OTHER THAN SURVEILLANCE.
1
IMPORTANT SAFETY INSTRUCTIONS
This manual contains important instructions for the following products:
-
HA-WCB1K24
HA-WCB2K48
HA-WCB3K48
This manual must be followed during installation and maintenance.
To reduce the
risk of personal injury and to ensure the safe installation and operation of the product,
you must carefully read and follow all instructions, cautions and warnings in this
manual.
Product Introduction
HA-WCB series of Solar Power Storage System is designed for the rated voltage
24Vdc(model HA-WCB1K24 only)/ 48Vdc system, built-in rechargeable and/or(VRLA)
valve-regulated lead-acid batteries, connecting with solar panel which located in
outdoor to generate the power. Just plug-in the connector from panels, then save the
solar energy in storage system. To ensure there has continuously power supply to
loads, it will automatically transfer to utility power when batteries in low condition.
Features
•
•
•
•
•
DC output voltage 24V or 48V. AC output voltage 110V or 220V. Max.
Built-in Used in high efficiency, deep cycle gel battery
MPPT control system
Battery reverses polarity/battery over discharge/overload protection.
Built-in automatically transfer to utility power to loads when run out of battery.
2
Product Description
Front Panel
1
2
3
4
5
1、POWER Switch:AC/DC power output ON/OFF
2、PV:Green LED lights when charger,please refer to P2
3、ALARM:Showing load condition, please refer to P2
4、BATTERY CAPACITY:Indicate battery capacity,please refer to P2
5、VOLTAGE METER:To measure AC output voltage
Back Panel
1
2
1、Solar power input
2、DC power output
3、AC power 220V or 110V input
4、AC power 220V or 110V output
3
3
4
Operation
Pre-startup Procedures
To avoid the occurrence of sparks and the risk of electric shock, please confirm the
power is switch off before plug-in.
Double-check all wiring connections well.
Using a digital voltmeter (DVM) or standard voltmeter, verify battery voltage.
Confirm the voltage is correct, confirm the polarity.
The components are close together and carry hazardous voltages. Use
appropriate care to avoid the risk of electric shock or equipment
damage.
Incorrect battery polarity will damage the inverter. Excessive battery
voltage also may damage the inverter. This damage is not covered by
the warranty.
Operating
Locating the solar panels in outdoor without shadow, and connecting to “solar power
input” in back panel. As long as the power switch on, AC 220V/AC 110V(optional)
and 24Vdc(model HA-WCB1K24 only)/ 48Vdc power can be output.
The battery power condition is monitored all the time after you connected the battery.
The system only need 10mA power to maintain system’s operation when switch off.
The power will be transferred to utility power automatically to support the power to
loads when run out of battery, and transferred back to battery’s power when battery’s
available capacity over 20%.
Display function
The controller has 5 LED indicators and one alarm to offer information. Under normal
operation, the controller would display charging status, battery capacity state and
error functions. When capacity getting change in battery, the light and buzzer will
come out to display condition.
4
Charge status (PV indicator)
Display charge status from solar panel to battery, the indicator will showing below:
Charging,(PV light on)
PV power supply
Un-charge(PV light off)
PV power does not supply
Battery capacity level (HI, MID, LOW indicator)
Display Battery capacity level, the indicator will showing below:
>75%
25-75%
<25%
The various LED indicator meaning estimated value from battery’s available capacity,
such as 25-75%, meaning capacity of the battery’s current situation.
Buzzer warning
The Sound signal from internal Buzzer for battery capacity warning, the indicator will
showing below:
Buzzer once
High Capacity
Buzzer 3 times
Mid Capacity
Buzzer 25 times
Low Capacity
5
Discharge Protection
When the battery is discharged, the battery capacity changes from high to low by time,
the system will make a prompt buzzer signal. When the battery capacity is less than
10%, discharge protection will be activated. 1 minute later after the buzzer 25 times
in a row, DC load will be off directly. And the system will transfer AC power from
battery supply to utility supply automatically.
Load status display (Alarm Indicator)
In the deeply discharge or load short circuit / overload condition, output load of the
controller will turn off. The indicator will showing below:
Normal operation
(ALARM OFF)
Discharge protection
(ALARM ON)
Overload or short circuit
(ALARM Flashing)
AC power status display (pointer voltmeter)
When the POWER switch ON, the voltage meter can immediately display the current
value of the output AC voltage
Normal operation
(POWER switch On)
Overload or battery no power
(POWER switch On)
6
Trouble Shooting
If you have trouble operating the camera, first refer to the following table. If the
problem persists, contact the supplier for support for more information.
Symptom
Error Messages
Possible Cause
Possible Remedy
1. Replace batteries.
2.
charge to the battery by itself,
No power from battery.
and load will re-open when power
ALARM indicator
return to MID.
red light on
Load overflow or short
No Power
ALARM indicator
supply to
Flashing
loads.
Used in charging function to
circuit
Battery voltage too high
or too low
Closes all loads and eliminates the
breakdown, then load terminal open
automatically in one minute later.
To check if any voltage from battery,
if not, means the controller
damaged.
HI & ALARM indicator
light on
1、 Replace the battery
Battery no power or overload
Voltmeter no reply
2、
charge to the battery by itself.
3、 Remove AC output load
1.
Battery is
empty
after a
short use
Used in charging function to
Check whether the battery had
been damaged.
2.
ALARM indicator
Battery has low capacity
Check whether the load
short-circuit causing over
discharge.
red light on
3.
Using the charging function to
charge again.
Battery is
not being
charged
Solar module is error or Check Solar module and the wiring,
PV POWER indicator
polarity reversed.
and correct the fault connection.
green light off
Battery
Buzzing
reverse
continuously.
Battery polarity reversed. Correct reversed.
7
Battery replacement
-
To replace the batteries by professional person.
-
Do not change battery size to the smaller or larger.
Pay attention on battery polarity, the box were designed with protection on
battery polarity, and buzzer reminding will come out when battery polarity.
Used in re-chargeable and/or(VRLA)valve-regulated lead-acid battery.
-
Safety recommendations
-
Batteries store a large amount of energy. Never short circuit a battery under all
circumstances. We recommend connecting a fuse (slow acting type, according to
the nominal controller current) directly to the battery terminal.
-
Batteries can produce flammable gases. Avoid making sparks, using fire or any
naked flame. Make sure that the battery room is ventilated.
Avoid touching or short circuiting wires or terminals. Be aware that the voltages
on specific terminals or wires can be up to double the battery voltage. Use isolated
-
-
tools, stand on dry ground and keep your hands dry.
Keep children away from batteries and the charge controller.
Please observe the safety recommendations of the battery manufacturer. If in
doubt, consult your dealer or installer.
8
Technical Data
Technical date is subject to change without prior notice.
9
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement