Farasys Hospital Bed Technical Training
Publicité
Publicité
LINKAN A/C TECHNICAL SUPPORT MANUAL
This manual consists of the detailed description for general/optional features of all LINKAN A/C products. Through these, the obtained knowledge will help to choose the suitable type of LINKAN A/C products.
The contents are classified as follows:
1. Actuator
3. Controller
4. Others
1. Actuator:
LINKAN A/C uses Acme thread spindle. LINKAN A/C actuator is a device to convert rotation motion into linear movement. The spindle specification will affect stroke, installation, thrust, speed, and self-lock force of actuator.
For a given kind of product series such as LA33, different pitches are available. The bigger the pitch, the smaller the thrust. Please refer to the following:
(velocity) mm/s
Pitch 9mm
Pitch 5mm
Pitch 3mm
Thrust
(N)
Because the length of nut is fixed, as the pitch value increases, the contact surface of thread in the nut decreases. To obtain enough contact surfaces for enough thrust, it requires more parallel threads on spindle. The type of LINKAN A/C pitch and thread is listed as below:
Type Pitch No. of Thread
LAxx.3 3mm/rev. Single thread
LAxx.4 4mm/rev. Double thread
LAxx.5 5mm/rev. Double thread
LAxx.9 9mm/rev. Triple thread nut
Pitch = the distance of nut rotation as spindle runs one cycle
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 3 LINKAN ASIA CO.
2007/11/9
1.2. Self-lock Force
Self-locking force is the supporting force of actuator. The bigger the pitch, the smaller the selflocking force. When the load is bigger than supporting force, the actuator will retract.
To enhance self-locking force, the brake option must be chosen (only available in LA31, LA32 series). By connecting to LINKAN A/C control box, the higher self-locking force can be obtained because the control box will connect actuator plugs and form closed circuit when actuator is not operating.
1.3. Brake System
When the pitch is big, the self-locking force of actuator is relatively small. To increase the selflocking force, “Brake” option can be ordered.
Currently, brake is only available in LA31, LA32 series. This brake system consists of brake spring covering a worm gear cylinder. One end of spring is fixed and the other end is free. As worm gear rotates in the reverse direction, brake spring is retracted to squeeze cylinder as brake action. When the worm gear rotates normally, the spring will be released and the worm gear cylinder rotates freely. The illustration is as (Pict. 1):
Therefore, brake system is directional while using. When it applies, it can only be adapted to ‘Push’ direction.
Nut
Fixed end
Spindle
Worm gear cylinder tight
Backward direction Brake spring loose
Forward direction
(Pict. 1)
1.4. End Stop Principles
LINKAN A/C actuators are constructed with 3 end stop principles. The following is the details:
(1) Limit Switch –
This is used with 2 built-in limit switches to disconnect the power to the motor. The limit switch is for the upper limit and lower limit of actuator respectively.
M upper limit lower limit
+ / + / -
Actuator applied with this principle: LA31, LA32, LA33, LA34
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 4 LINKAN ASIA CO.
2007/11/9
(2) Electronic Overload Protection –
As the nut approaches the limit, the current of motor will rapidly increase. Thus, the control box connected to the working actuator must be able to detect and cut off the current.
Thus, under this principle, as the load exceeds the setting value, the control box will be short circuit to stop the movement.
Control box with this feature: CB09, CB12, CB16, CB22.
Actuator required this feature:LA36 (necessary with CB12)
(3) Mechanical Overload Protection
When nut moves to end position, nut will rotate freely to achieve the required function. The illustration is as the below:
Declutch device When the device approaches the limit position, the nut will rotate freely
Limit position
Actuator with this feature: LA37.
1.5. Stroke Length and Installation Dimension
Stroke Length:
The extending distance of piston in the actuator. stroke length
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 5 LINKAN ASIA CO.
2007/11/9
Installation dimension:
The distance between the piston rod eyes and back fixture of the actuator. basic dimension
From above, it shows that the installation dimension will change upon the stroke.
Thus, it follows the rules:
The smallest installation dimension = basic dimension + stroke length
Example: LA33.3N-20-200-RHS
The smallest installation dimension = 173 + 200 =373mm
1.6. Thrust
The thrust of LINKAN A/C actuator ranges from 1500N to 6000N. Thrust is the first consideration for choosing right actuator and control box.
Required thrust(F) is upon the load to lift. Besides the weight(L) of the load, the further consideration should include the geometry of mechanism: The illustration is as follows:
Fulcrum b L a
F b L=F a
F= L
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 6 LINKAN ASIA CO.
2007/11/9
Another important point is the installation position of actuator. Actuator cannot suffer too much lateral force. Otherwise actuator will be damaged.
1.7. Back Fixture
LINKAN A/C offers 2 types of back fixture as follows:
V Type (vertical installation) H Type (horizontal installation)
Currently, Quick Release is only available in LINKAN LA31 and LA32 series.
The quick release function is for the backrest position of hospital bed. In case of emergency, for example, patients need CPR therapy due to heart exhaustion, it will require lowering down quickly the backrest to horizontal position. For installation and other points, please refer to LA31.Q, LA32.Q installation.
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 7 LINKAN ASIA CO.
2007/11/9
Currently, Reed Switch is only available in LINKAN A/C LA31, LA32 actuator series.
Reed Switch is a switch activated by magnetic field and placed on the plastic cover over the worm wheel gear. In worm wheel gear, there is an 8-pole magnetic disc. As the worm wheel gear rotates one cycle, Reed Switch will send out 8 signals (pulses). Thus, the software in the control box can facilitate this signal to design control program.
1.10. Safety Nut
LINKAN A/C actuator can equip with a safety nut, which is an auxiliary nut. In normal condition, it will move along with main nut. When main nut breaks down, safety nut will support the load. Actuator can be further activated but this movement is only limited to lower the load. In this condition, it also indicates repairing needed.
Currently, this feature is available in LA31, LA32, and LA33 series.
1.11. Spline Function
Actuator with this feature can be only applied in ‘push’ application. It is not allowed to be used in
‘pull’ application. When piston is retracting, this is a device for safety. For example, when this function is applied in backrest position of bed and if something is blocked in the motion structures, the spline function can prevent the risk of injury or danger.
Spline
Push
Inner tube
Spline function is only for applications of light load 2000N. If the load is too heavy and when the block stuff makes the spline declutched, the danger of rapid lowering may occurs after the block stuff is removed.
Currently, only LA33 is available with this feature.
1.12. Duty Cycle
Electronic components are vulnerable to high temperature.
As the actuator is operating, the inner temperature will increase. This temperature rise occurs in the coils of motor. The rising level of temperature is upon the load. If the operation continues, the heat will damage the insulation of motor thus the motor breaks down. From this aspect, the extent of continuous movement under heavy load is limited.
It is important to comply with the duty cycle indicated on the actuator or control box. If the operation exceeds the duty cycle, the actuator will be overheated and possibly damaged. Unless any particular note in the label, duty cycle under continuous use is max 10% or 18-minute halted time after
2-minute continuous use.
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 8 LINKAN ASIA CO.
2007/11/9
2. Control Box
2.1. Earth Connection
LINKAN A/C control box offer 2 choices – general insulation and earth connection protection.
General insulation is double insulated, no earth connecting devices. The main applied field is not medical one because it cannot provide additional protection against electrical shock of high-risk voltage.
Earth connection has an earth-connecting device, which can double insulate the transformer through bed frame to be connected to the ground via mains power cable. The inner components in the control box have no actual earth connecting. At this moment, the earth connection feature is only available for
CB09, CB12, CB16 and CB22.
Earth connection has 2 main fuses, one is in input and the other is in neutral. The earth connection has the follow advantages:
.Increase the level of electrical static discharge (ESD) immunity. (Provided that mains power cable is connected to power supply)
.When the bed frame of application is connected to the ground, it will usually decrease the electrical-magnetic field for applications.
Earth connection is mainly applied or required in medical applications. Because the application is connected to earth, it will offer more protection from electric shock.
Some places require earth connection to prevent from electrical static discharge and electrical magnetic compatibility (EMC). Thus, metal bed frame, power cable/actuator placement need to match each other and to achieve the performance. However, for different environments and different requirements in different countries, the considering factors are different. Currently, there is no common standard. For any further information, please contact LINKAN A/C technical department.
2.2. Duty Cycle
The coils of transformer in LINKAN A/C control box will raise the temperature when there is continuous operation under loads. If the duty cycle is exceeded, control box will encounter the risk of overheat and damage.
Unless there is particular note in the label, under continuous operation, the max. duty cycle is 10% or
18-minute halted time after 2-minute continuous use.
2.3. Transformer
Currently, LINKAN A/C control boxes apply 2 different transformers. One is EI-core type (such as the one in CB02) and the other is toroidal (such as the one in CB05, CB06, CB09, CB12, CB16, CB22 and CB24).
The advantages and disadvantages between these 2 types:
EI-core type –
Advantages: small dimension and cheaper
Disadvantages: Lower efficiency
Toroidal type –
Advantages: better efficiency
Disadvantages: bigger dimension and more expensive.
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 9 LINKAN ASIA CO.
2007/11/9
Transformer v.s. the speed of actuator
The secondary voltage from a transformer will decrease when the current consumption occurs. The bigger the current consumption is, the lower the voltage is. Thus, the speed of actuator will relatively decrease.
The degree of voltage drop is upon the capacity of transformer. Under the same load, the decreasing level of bigger transformer is less than that of smaller transformer. Under given condition, toroidal type has smaller drop level than EI type does.
Some control boxes such as CB12, CB16, CB22 and CB24 are available with Turbo function. This is to supply higher voltage under heavy load thus the speed will not drop. Besides, higher speed can finish the operation faster and prevent actuator or control box from overheating.
*
Transformer
*
AC29V
AC120V or AC230V
Primary voltage
Secondary voltage
Primary voltage is the power input
Secondary voltage is the low voltage output to supply power to the actuator and control box
2.4. Electronic Overload Protection
Electronic Overload Protection in LINKAN A/C control box can be classified into the following 2 types:
A: Current cut-off (such as CB09, CB12, CB16, CB22 and CB24)
B: Pulse (speed) monitoring (such as CB05)
A.: Current cut-off
Actuator requires higher current when the load becomes heavier. Thus, in this design, there is a detecting circuit to check at any time the current supplied from control box to actuator. As the current reaches the setting value such as 4.5A, the protective circuit is activated and cutting off current to the actuator.
When actuator reaches 2 end-stop positions, actuator current will rapidly increase. Then, the protective circuit will quickly cut off current to actuator and stop the movement.
B: Pulse (speed) monitoring
This feature is similar to current cut-off but not so fast. Actuator needs to be equipped with end stop switch and reed switch such as LA31.4BR-15-200-BHD
(LA32.4BR-15-200-BHD). This design facilitates the pulse sent back by actuator’s reed switch to judge the movement speed and whether it reaches limit. Then, if it is, the current supply will be cut off.
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 10 LINKAN ASIA CO.
2007/11/9
2.5. Wake-up Feature
LINKAN A/C control box CB22 and CB24 is available with wake-up feature. This control box will cut off the power and enter ‘sleeping’ status when the user does not operate controller for some time.
This can achieve the energy-saving purpose and prevent running out battery power when no connection to mains power. When it requires operation, the system can be activated (wake up) by handset control.
2.6 Turbo Function
LINKAN A/C control box (CB12, CB16, CB22 and CB24) is available with turbo function. It is to increase the speed of actuator when current consumption is lower than a certain level (approx. 1.8A).
Under this condition, the secondary voltage will be switched from low voltage (AC22V) to high voltage
(AC29V).
Another type is TR05+CB05, a permanent high voltage at AC29V for the higher speed.
2.7 Battery
LINKAN A/C use rechargeable lead-acid battery, which comprises 2 pcs of DC12V/1.2Ah batteries.
In normal condition, the battery life is approx. 2 years. Charging times can be also expressed as the life of battery:
If the battery capacity is about 100%↔70%, the chargeable cycle is about 1200 times.
If the battery capacity is about 100%↔50%, the chargeable cycle is about 400 times.
If the battery capacity is about 100%↔ 0%, the chargeable cycle is 180 times.
Note:
A: It is advised to use battery electricity as little as possible and to charge the battery as frequently as possible. Battery will have the longest life in this way.
B: Because of self-discharge, it cannot expect that battery is under the saturated status when customers receive batteries. It is advised that when customers receive the battery, the battery can be immediately recharged. Another condition is to charge the battery within 5 months counted from production date. The earlier the battery being charged, the longer the life being extending. The charging time for above condition should be maintained between 24-48 hours.
C: Recharging current:
Typical principle: Max. charging current = 0.25 x battery capacity (Ah)
BA16 = 0.25 x 1.2 Ah = 0.3A
D: Charging voltage:
DC 24V system = The max. DC 27.6V.
E: Charging time:
BA16 charging time is about 1.2Ah÷0.3 = approx. 4~5 hrs.
Theoretically, it needs 4~5 hrs to charge the battery capacity from
0% to 80%. For 100% capacity, it will need at least 10 hrs.
The battery alarm in the control box will be activated when the capacity is lower down to 18V. To optimize battery life, it is better to charge battery before alarm is activated
Therefore, it is advised that our customers can have the control box plugged to the mains all the time to keep the battery capacity saturated.
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 11 LINKAN ASIA CO.
2007/11/9
3. Control box
Controller is principally a part of LINKAN A/C system. However, it is the part of user’s direct touch.
Thus, when making choices, several factors should be noticed:
1. Controller type. According to usage, it can be classified as handset HBXX, Foot Switch
FS, Attendant Control Panel ACP, Remote Control HB6X etc.
2. Channels for operation. Please refer to Table 1.
3. Color.
4. The cable length, type and plug specification.
5. Functions for operation to comply with control box. Please refer to Table 2.
7. Label.
(Table 1) (Table 2)
CH
Controller
CH1 CH2 CH3 CH4
Control box
Controller
HB3× ● ● ● HB3×
CB02 CB05 CB06 CB07 CB09 CB12 CB16 CB22 LA30
● ● ● ● ● ● ●
HB6×
HB8×
● ●
● ● ● ●
ACP×S
FS
FLS
HB23
● ● ● ●
● ●
● ● ● ●
●
HB6×
HB8×
HB23
●
● ● ● ● ● ● ● ●
ACP×S
FS
●
●
● ● ● ●
●
FLS ●
● ●
●
● ●
●
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 12 LINKAN ASIA CO.
2007/11/9
Label:
HB3×
Order NO:
(HB31-00) (HB32-00) (HB32-01) (HB32-02) (HB33-00) (HB33-01)
(HB31S-C0) (HB32S-C0) (HB32S-C01) (HB32S-C2) (HB33S-C0) (HB33SC-C1)
Price NO:
HB8×
Order NO:
(HB81-00) (HB82-00) (HB83-00) (HB83-02) (HB84-00)
(HB81-C0) (HB82-C0) (HB83-C0) (HB83-C4) (HB84-C0)
Price NO:
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 13 LINKAN ASIA CO.
2007/11/9
Order NO:
(HB84-01) (HB84-05) (HB84-06) (HB84-07) (HB84-08 For ACP)
(HB84-C1) (HB84-C3) (HB84-C4) (HB84-C02 For CB16) (HB84-C1 For ACP )
Price NO: (HB84-C03 For CB06)
ACP
Note: 1. HB84-C02 is for CB16 only; HB84-C03 is for CB06 only. Pictures on the cover are the same; but PCB functions are different.
2. HB84-C1 (HB-01) can not used with ACP. If ACP needed, please choose HB84-C1 (HB84-08).
ACP 3-S
(ACP 3-S)
& www.linkan.com.tw
ACP 4-S
&
www.linkan.com.tw
(ACP 4-S)
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 14 LINKAN ASIA CO.
2007/11/9
4. Others
4.1. IP Degree
IP degree is a classification system, which indicates protection level from certain materials such as dust and water impact to electrical equipment and its enclosures. The following is the description for IP degree. The IP degree is defined as description in EN/IEC 060529.
IP 5 4
This digital number indicates the IP degree of protection against ingress of water with harmful effects. The definition is as follows:
0 – No protection
1 – Protection against vertical falling water drop
2 – Protection against vertical falling water drop as the enclosure is ± 15°
3 – Protection against spray water between 0° ~ 60°
4 – Protection against splashing water from any direction with limited ingress
5 – Protection against jetting of water from any direction with limited ingress
6 – Protection against powerful water jetting, with limited ingress
7 – Protection against temporary immersion
8 – Protection against continuous immersion
This digital number indicates the IP degree of protection from ingress of solid external objects.
. The definition is as follows:
1 – No protection
2 – Protection against solid external objects of 50mm diameter or greater
3 – Protection against solid external objects of 12.5mm diameter or greater
4 – Protection against solid external objects of 2.5mm diameter or greater
5 – Protection against solid external objects of 1.0mm diameter or greater
6 – Protection against dust
7 – Protection of sealing
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 15 LINKAN ASIA CO.
2007/11/9
4.2. Actuator Feature and Its Combination
Type
spec.
LA31.3
LA31.4 LA31.5
LA31.9
LA33.3
LA33.4
LA34 LA36 LA37 LA38.I
Stroke(mm) 100~250 100~250 100~250 100~250 50~250 50~250 100 ╳ 100~250 200~300 150~200
● ● ● △ Brake(B)
Safety nut(M) ●
Quick release(Q)
Reed switchR) ●
Spline(S)
Standard motor(B)
●
Fast motor (S) ●
Jack Cable ●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
● ●
☆
●
●
● ●
△
△
△
△
△
△
Din Cable ● ● ● ●
Type
spec.
LA32.3 LA32.4 LA32.5 LA32.9 LA35.3 LA35.6
Stroke(mm) 100~250 100~250 100~250 100~250 100~200 100~200
● ● ● Brake(B)
Safety nut(M) ● ● ● ●
● ● Quick release(Q)
Reed switchR) ● ● ● ● ● ●
Spline(S)
Standard motor(B) ●
● Fast motor (S)
Jack Cable ●
●
●
●
●
●
●
●
●
●
●
●
●
●
△
Note:
☆ Motor in LA36 is different from that in other actuator series.
△ LA38.O is a lifting column with actuator outside.
The standard specification is with LA33.
For any particular features for further options, please contact LINKAN A/C technical department.
Din Cable ● ● ● ● ● ●
4.3. Control Box Feature and Its Combination 4.4. LINKAN System Combination
type features
CH
Earth connection
External fuse
EI type transformer ●
Toroidal transformer
Turbo function
Overload short-circuit
External battery
Memory function
CB02 CB05 CB06 CB07 CB09 CB12 CB16 CB22
3 2 4 4 4 4 4
☆1 ●
☆2
☆3
●
●
●
●
9V ●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
Cable for actuator Jack Din T-Din Jack T-Din Jack Jack Jack
Note:
☆1 CB05 must match with TR05. TR05 is with toroidal transformer.
☆2 CB05 is with permanent turbo function.
☆3 CB05 overload short-circuit is by pulse (speed) monitoring。
Control box
Actuator
Controller
LA31
LA32
LA33
LA34
CB02 CB05 CBO6 CB07 CB09 CB12 CB16 CB22
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
LA37
LA38.I
LA38.O
HB3×
HB6×
HB8×
ACP
FS
FLS
●
●
●
●
●
●
●
△
●
●
△
△
△
△
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
△ It is possible to have CB05+LA38.O. But it is necessary to contact first with LINKAN A/C technical department.
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 16 LINKAN ASIA CO.
2007/11/9
3 Actuator
3-1 LA31
LA31 is a very quiet and powerful actuator designed for a variety of applications, such as those in furniture, care or rehabilitation fields; it is available with a wide range of options and safety protections.
Features:
24V DC permanent magnet motor
Thrust up to 6000N; Speed 3.0~16.7mm/s
Built-in limited switches (not adjustable)
High-strength plastic housing protects motor and gear
Scratch and wear-resistant powder painted outer tube
Strong wear and corrosion resistant stainless steel inner tube
Elegant and compact design with small installation dimensions
Steel piston rod eye
Zinc alloy back fixture
Duty cycle: Max. 10% or 2 min./ 18 min. in continuous use
Ambient temperature: +5℃ to +40℃
Protection class: IP54
Color: Black
Options:
LA31 can be fitted with a brake for increasing self-lock effect
Safety nut
Protection class: IP66 (not for wash tunnels)
Reed-Switch
Quick-Release Q
Back stretch sleeve fixture (For only Quick-Release function)
0.2/ 0.4m coiled cable with DIN or Jack plug
Back fixture position 0° or 90°
Steel groove piston rod eye
Fast motor
Color: Gray-White (Min. order: 1,000 pcs)
Can install Hall Sensor function (Contact R & D department of LINKAN A/C first)
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 17 LINKAN ASIA CO.
2007/11/9
LA31 Ordering Example:
LA31. 4 B M R Q – 15 – 100 – B H D
TYPE OF PLUG (Notice plug on the control box)
D:DIN
J:JACK
E:3P JACK FOR CB24
X:WITHOUT PLUG
BACKFIXTURE DIRECTION
(The direction of actuator installation)
H:HORIZONTAL
V:VERTICAL
TYPE OF MOTOR
B:STANDARD
S:FAST
(The raising of motor power makes actuators more fast and powerful. But the working cycle becomes small)
COLOR
–:Black
+:Gray-white
CABLE LENGTH
100=100cm
150=150cm
200=200cm
STROKE LENGTH
10=10cm
15=15cm
20=20cm
25=25cm
30=30cm
QUICK RELEASE Q
( Only used with 5mm pitch screw. Q is for CPR function and can makes beds return to original position quickly by manual operation)
REED SWITCH
R :As the worm wheel gear rotate one cycle, Reed Switch will send out 8 signals (pulses). Thus, control box can read signals to operate memory and parallel control.
H:Unipolar Hall Sensor
T:Bipolar Hall Sensor
SAFETY NUT M ( Only used with 4mm pitch spindle and for avoiding main nut on the spindle breaking down and then bed sliding down suddenly)
BRAKE B:
(Raise self-lock power to prevent the sliding of fixed beds.)
SPINDLE PITCH
3:3.0 ㎜ (Small pitch, power: large, speed: slow)
4:4.0 ㎜
5:5.0 ㎜
9:9.0 ㎜ (Large pitch, power: small, speed: fast)
ACTUATOR TYPE LA31-BASIC
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 18 LINKAN ASIA CO.
2007/11/9
Dime sions:
Back direction: (Direction of installation) Option for Quick Release accessory
V type (Vertical install) H type (Horizontal install) (Back stretch sleeve fixture)
Screw:
Groove Not-Groove
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 19 LINKAN ASIA CO.
2007/11/9
Basic Installation Dimension:
Actuator Stroke mm 100
Basic Installation Stroke mm 288
Stretch Stroke mm 388
Installation Dimension for Q function :
Actuator Stroke mm 100
Basic Installation Stroke mm 377
Stretch Stroke mm 477
150
323
473
200
373
573
250
423
673
300
473
773
Notice (Installation):
★ If the stroke of LA31 is less than 100mm, all basic installation dimension are 288mm
★ When the load is over 4000N, the longest stroke of a actuator is 250mm
★ For a actuator equipped with Q function: basic installation dimension is Stroke + 277mm
Notice (for the installation of Q function)
★ The effective stroke length for Quick Release is:
Standard stroke length minus 10 ㎜
150
427
577
200
477
677
E.g. Actuator with quick release is equipped with 150mm stroke length. The effective stroke length for this type is ≦140 ㎜
★ When LA31 actuator equip Quick Release function, spindle need to be 5mm pitch. The needed released
power of actuator is 35 kgs.
★ LA31 is not suitable for the pulling device. Suggestion: Actuator is suitable for the load in pushing situations.
★ Back stretch sleeve fixture is suggested for Quick Release function
Data & Graph:
Power Supply: DC24V
Spindle type
Spindle
Pitch
(mm)
Max load
【N】
Typical
Amp.
Typical speed
【mm/s】
Push Pull Full load Unloaded Full load
Standard 24V motor (Duty Cycle:10% )
LA31.3 3 3.0A
4000 3.6A
LA31.5 5 1.6A
2000 1.6A
4000 2.8A
1500 1.7A
Fast 24V motor (Duty Cycle:5% )
Selflock Max
【N】
Push
2000
LA31.3 3 4.0A
4000 4.6A
LA31.5 5 2.1A
4000 3.5A
1500 2.5A 14.3
※The data above is with DC24V power supply. If you need the data with compatible control boxes, please contact LINKAN A/C technical department.
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 20 LINKAN ASIA CO.
2007/11/9
Standard 24V motor:
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 21 LINKAN ASIA CO.
2007/11/9
Fast 24V motor:
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 22 LINKAN ASIA CO.
2007/11/9
3-2 LA33
LA33 has an elegant and streamline design suitable to use in furniture, rehabilitation and sports sectors. LA33 is developed for push applications; it has a very strong construction and competitive price.
Features:
24V DC permanent magnet motor
Thrust 4000N~ 6000N
Built-in end stop signal switches (not adjustable)
Stroke length: 5cm~30cm
The outside tunnel is aluminum material, exquisite and classical
Elegant and compact design; small installation dimension
Duty cycle: Max. 10% or 2 min./ 18 min. in continuous use
Ambient temperature: +5℃ to +40℃
Color: Black
Options:
Back fixture position 0° or 90°
Three types for rod eye: Groove+Round、Oval、Round
T-Din Jack Plug for mounting with CB06 or combining LA30
Spline device
Protection class: IP51
Can install Hall Sensor function (Contact R & D department of LINKAN A/C first)
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 23 LINKAN ASIA CO.
2007/11/9
LA33 Ordering Example:
LA33. 3 S R – 20 – 200 –R H S
TYPE OF PLUG (Notice plug on control box)
S:JACK (STANDARD)
X:WITHOUT PLUG
T:T-Din Jack(FOR CB06 or LA30)
D:DIN
BACKFIXTURE DIRECTION (Direction of actuator installation)
H:HORIZONTAL
V:VERTICAL
TYPE OF EYES (Front install head in the spindle)
O:OVAL
R:ROUND
CABLE LENGTH
50= 50cm (Mount with CB06)
100=100cm
150=150cm
200=200cm
STROKE LENGTH
5= 5cm
10=10cm
15=15cm
20=20cm
25=25cm
30=30cm
Reed Switch
R:As the worm gear rotate one cycle, Reed Switch sends out 4 signals(pulses). R can let control box to read signal and run memorizing and positioning control.
H:Unipolar Hall Sensor
T:Bipolar Hall Sensor
FUNCTION (Avoid being clipped and fixed when actuator encounter obstacles in the movement, only for Push)
S:SPLINE (3mm pitch spindle only)
N:Without SPLINE
SPINDLE PITCH
3:3 ㎜
6:6 ㎜
ACTUATOR TYPE LA33-BASIC
Rod Eye Type Back Direction (Direction of Installation)
V type(Vertical install) H type(Horizontal install)
“R”
“O”
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 24 LINKAN ASIA CO.
2007/11/9
Dimensions: Installation Dimensions:
If LA33 stroke exceeds 100 mm, basic installation is S+173 mm
LA33 Dimensions
Actuator Stroke mm
Basic Installation Dimension mm
Stretch Stroke mm
Notice:
100
288
388
150
323
473
200
373
573
250
423
673
300
473
773
3mm pitch only when using rod eye with Groove + Round specification
T-Din Jack Plug needed when mounting with CB06, 100mm above stroke of actuators needed when mounted with CB06
Spline function is only used with LA33.3
Data & Graph:
Type
Spindle
Pitch
(mm)
Max load
【N】
Typical
Amp.
Typical speed
【mm/s】
Push Pull Full load Unloaded Full load
Selflock
Max【N】
Push
LA33.3 3 6000 3.0A 4.1 3.0 6000
LA33.6 6 4000 4.2A 7.5 4.3 4000
(Duty Cycle:10% )
※ The data above is the standard of using DC24V power supplier. If you need the data of the compatible control boxes, please contact with LINKAN A/C technical department.
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 25 LINKAN ASIA CO.
2007/11/9
3-3 LA36
LA36 is an innovative actuator. The unique design is suitable for many applications in furniture, rehabilitation, medical and industry sectors. The actuator system can be operated manually when no electricity. The distinctive mechanical structure is a patent design. The electrically driven system with manual operation is the most outstanding feature.
Features:
24V DC permanent magnet motor
Force: 4000~6000N
Elegant and compact design; the installation dimension is flexible
Both electrical and manual functions. Possible to be installed directly into traditional crank beds
Low noise
Duty cycle: Max. 10% or 2 min./ 18 min. in continuous use
Ambient temperature: +5 to +40 ℃
Protection class: IP31
Color: black
Used with CB12 only
Options:
Housing color: Gray-White (Min. Order: 1,000 pcs)
MOLR: Manual crank with overload protection device
Crank
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 26 LINKAN ASIA CO.
2007/11/9
LA36 Ordering Example:
LA36. 4 – 200 – J
TYPE OF PLUG (Notice plug on control box)
J:JACK
CABLE LENGTH
200=200cm
250=250cm
FORCE
4:4000N
6:6000N
ACTUATOR TYPE LA36-BASIC
Dimensions:
Notice:
To obtain the best performance, it is necessary to use actuator under these conditions: the outside diameter of the spindle arbor must be between Ø18 and Ø20mm, the pitch of the tube must be
4mm or 3mm.
If the spindle connected with LA36 didn’t equip built-in over-load protection device, please choose
MOLR. If the spindle already equipped it, crank can be common one.
Only used with CB12 control box
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 27 LINKAN ASIA CO.
2007/11/9
3-4 LA38
LA38 Lifting Column is proper design for applying vertical movement of heavy materials. It is just need an actuator, a proper control box, and a handset and then can easily be operated and used.
The advanced design and the high-quality structure can sustain high bending force and have long life span.
LA38 is ideal for lifting heavy load vertically, such as working tables, operation table, obstetric table and other applications.
Features:
LA38 is a special-designed elastic lifting, and can equip Linkan A/C linear actuator.
Special design to overcome the bending force and torque when applications lift vertically.
High thrust, long life-span, low noise.
Compact design with high strength.
The duty cycle is upon the selected LINKAN A/C actuator
Ambient temperature: +5℃ to +40℃
Protection class: IP54
LA38 built-in actuator can be used with CB09 and CB16 control box
LA38 built-out actuator can be used with CB02, CB05, CB07, CB09 and CB16
Options:
Reed-switch (For built-out actuator , easy for control box to read signals; then execute memory and
parallel functions)
Gas spring (to increases the lifting capacity)
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 28 LINKAN ASIA CO.
2007/11/9
LA38 Ordering Example:
LA38. I 2 – 3 – 200 – 415
Installation Dimensions mm
365=365mm (stroke=150mm)
415=415mm (stroke=200mm)
465=465mm (stroke=250mm)
515=515mm (stroke=300mm)
Stroke Length mm
150=150mm
200=200mm
250=250mm
300=300mm
Spindle pitch mm
3:3 ㎜
4:4 ㎜
Sections
2:2 sections
3:3 sections
Structure
I :With actuator inside—Steel
Dimensions:
O:With actuator outside—Steel
A:With actuator inside—Aluminum Alloy
A2 I2 O2
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 29 LINKAN ASIA CO.
2007/11/9
LA38.A2 Basic Installation Dimension
Actuator Stroke mm
Basic Installation Dimension mm
Lifting Total Height mm
LA38.I2 Basic Installation Dimension
Actuator Stroke mm
Basic Installation Dimension mm
Lifting Total Height mm
LA38.O2 Basic Installation Dimension
Actuator Stroke mm
Basic Installation Dimension mm
Lifting Total Height mm
200
415
615
200
415
615
150
369
519
250
465
715
250
465
715
200
419
619
300
515
815
300
515
815
LA38.O2-4-XXX-XXX
LA38.O2-3-XXX-XXX
LA38.I2-4-XXX-XXX
LA38.I2-3-XXX-XXX
4000N
6000N
3000N
6000N
Speed 0/fullmm/s
5.4/3.8 mm/s
4.1/3.0 mm/s
6.0/3.0 mm/s
4.1/3.0 mm/s
Current full-A
2.6A
3.0A
3.5A
4.0A
Max Bending
Force- N/m
500 N/m
500 N/m
1000 N/m
1000 N/m
Notice:
Stroke length:
There are two specifications for LA38.O2 : 200mm and 150mm.
There are three specifications for LA38.I2: 300mm, 250mm and 200mm.
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 30 LINKAN ASIA CO.
2007/11/9
3-5 LA37
LA37 is an actuator with robust spindle, unique overload device and strong motor. The actuator structure is a patent design suitable for the field of hospitals, cares, and rehabilitation. When the power is off or the motor break down, the actuator can be operated with manual crank. Besides, the installation is much easier. The manual and electrical dual operation is a feature of LA37.
Features:
24V DC permanent magnet motor
Thrust from 4000N to 6000N
Robust structure design with easy installation
Electrical and manual dual operation
Built-in overload structure design
Low noise
Duty cycle: Max. 10% or 2 min./ 18 min. in continuous use
Ambient temperature: +5℃ to +40℃
Protection class: IP31
Color: Black
Used with CB07-S control box
Options:
Housing color: Gray-White (Min. Order: 1,000 pcs)
Crank
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 31 LINKAN ASIA CO.
2007/11/9
LA37 Ordering Example:
LA37. 6– 10 – 250 – H J
Dimensions:
TYPE OF PLUG (Notice plug on control box)
J:JACK PLUG
BACKFIXTURE DIRECTION (Direction of installation)
H:HORIZONTAL
V:VERTICAL
CABLE LENGTH
200=200cm
250 = 250cm
STROKE LENGTH
10=10cm
15=15cm
20=20cm
25=25cm
FORCE
4: 4000N
6: 6000N
ACTUATOR TYPE LA37
12
1
Notice:
The length (L) is the same for S=100mm & 150mm
L=275+150=425mm
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 32 LINKAN ASIA CO.
2007/11/9
LA37 Installation Dimension:
Actuator Stroke mm
Basic Installation Stroke mm
100
425
150
425
200
475
250
525
Stretch Stroke mm
Notice:
525 575 675 775
The basic installation dimension is the same for 100mm and 150mm stroke
Can choose manual crank for the power shortage or motor breakdown (Option)
4000N actuator suggested if used in back、leg parts of hospital beds. 6000N actuator suggested if
Lifing column is used in lifting beds.
Must used with CB07-S control box
The overload protection device will work when actuators move upper and lower limit. Then all actions should be stopped. If operations still continue, actuator will warn users by making buzz sound.
When the load is more than 3000N or the applications of the impact, please apply actuator to the pushing direction.
Data & Graph:
Type
Max. load【N】
Current
【A】
Typical Speed
【mm/s】
Self Lock
Max.【N】
Push Pull Full Load Push
LA37.4
LA37.6
4000 3000 3.6 10 5
6000 3000 3.9 5.7 3.6
3000
6000
(Duty Cycle: 10%)
※The data above is with DC 24V power supply. For need of data with compatible LINKAN A/C control box, please contact LINKAN A/C technical department.
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 33 LINKAN ASIA CO.
2007/11/9
3-6 LA32
LA32 is a very quiet and powerful actuator designed for a variety of applications, such as those in furniture, care or rehabilitation fields; it is available with a wide range of options and safety protections.
Features:
24V DC permanent magnet motor
Thrust 1500N~6000N; Speed 3.0~16.7mm/s
Built-in limited switches (not adjustable)
High-strength plastic housing protects motor and gear
Scratch-resistant and wear-resistant powder painted outer tube
Strong wear and corrosion resistant stainless steel inner tube
Elegant and compact design with small installation dimensions
Steel piston rod eye
Zinc alloy back fixture
Duty cycle: Max. 10% or 2 min./ 18 min. in continuous use
Ambient temperature: +5℃ to +40℃
Protection class: IP54
Color: Black
Options:
LA32 can be fitted with a brake for increasing self-lock effect
Safety nut
Protection class: IP66 (not for wash tunnels)
Reed-Switch
Quick-Release
Back stretch sleeve fixture (For only Quick-Release function)
0.2/ 0.4m coiled cable with DIN or Jack plug
Back fixture position 0° or 90°
Steel groove piston rod eye
Fast motor
Color: Gray-White (Min. order: 1,000 pcs)
Can install Hall Sensor function (Contact R & D department of LINKAN A/C first)
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 34 LINKAN ASIA CO.
2007/11/9
LA32 Ordering Example:
LA32. 4 B M R Q – 15 – 100 – B H D
TYPE OF PLUG (Notice plug on the control box)
D:DIN
J:JACK
E:3P JACK FOR CB24
X:WITHOUT PLUG
BACKFIXTURE DIRECTION
(The direction of actuator installation)
H:HORIZONTAL
V:VERTICAL
TYPE OF MOTOR
B:STANDARD
S:FAST
(The raising of motor power makes actuators more fast and powerful. But the working cycle becomes small)
COLOR
–:Black
+:Gray-white
CABLE LENGTH
100=100cm
150=150cm
200=200cm
STROKE LENGTH
10=10cm
15=15cm
20=20cm
25=25cm
30=30cm
QUICK RELEASE Q
( Only used with 5mm pitch screw. Q is for CPR function and can makes beds return to original position quickly by manual operation)
REED SWITCH
R : As the worm wheel gear rotate one cycle, Reed Switch will send out 8 signals (pulses). Thus, control box can read signals to operate memory and parallel control.
H:Unipolar Hall Sensor
T:Bipolar Hall Sensor
SAFETY NUT M :(Only used with 4mm pitch spindle and for avoiding main nut on the spindle breaking down and then bed sliding down suddenly)
BRAKE B:
(Raise self-lock power to prevent the sliding of fixed beds.)
SPINDLE PITCH
3:3.0 ㎜ (Small pitch, power: large, speed: slow)
4:4.0 ㎜
5:5.0 ㎜
9:9.0 ㎜ (Large pitch, power: small, speed: fast)
ACTUATOR TYPE LA32-BASIC
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 35 LINKAN ASIA CO.
2007/11/9
Dimensions:
Back direction: (Direction of installation) Option for Quick Release accessory
V type (Vertical install) H type (Horizontal install) (Back stretch sleeve fixture)
Screw:
Groove Not-Groove
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 36 LINKAN ASIA CO.
2007/11/9
Basic Installation Dimension:
Actuator Stroke mm 100
Basic Installation Stroke mm 288
Stretch Stroke mm 388
Installation Dimension for Q function :
Actuator Stroke mm 100
Basic Installation Stroke mm 377
Stretch Stroke mm 477
150
323
473
200
373
573
250
423
673
300
473
773
Notice (Installation):
★ If the stroke of LA32 is less than 100mm, all basic installation dimension are 288mm
★ When the load is over 4000N, the longest stroke of a actuator is 250mm
★ For a actuator equipped with Q function, basic installation dimension is Stroke + 277mm
Notice (for the installation of Q function)
★ The effective stroke length for Quick Release is:
Standard stroke length minus 10 ㎜
150
427
577
200
477
677
E.g. Actuator with quick release is equipped with 150mm stroke length. The effective stroke length for this type is ≦140 ㎜
★ When LA32 actuator equip Quick Release function, spindle need to be 5mm pitch. The needed released
power of actuator is 35 kgs.
★ LA32 is not suitable for the pulling device. Suggestion: Actuator is suitable for the load in pushing situations.
★ Back stretch sleeve fixture is suggested for Quick Release function
Data & Graph:
Power Supply: DC24V
Spindle type
Spindle
Pitch
(mm)
Max load
【N】
Typical
Amp.
Typical speed
【mm/s】
Push Pull Full load Unloaded Full load
Standard 24V motor (Duty Cycle:10% )
LA32.3 3 3.0A
4000 3.6A
LA32.5 5 1.6A
2000 1.6A
4000 2.8A
1500 1.7A
Fast 24V motor (Duty Cycle:5% )
Selflock Max
【N】
Push
LA32.3 3 4.0A
4000 4.6A
LA32.5 5 2.1A
4000 3.5A
1500 2.5A 14.3
※The data above is with DC24V power supply. If you need the data with compatible control boxes, please contact LINKAN technical department.
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 37 LINKAN ASIA CO.
2007/11/9
Standard 24V motor:
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 38 LINKAN ASIA CO.
2007/11/9
Fast 24V motor:
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 39 LINKAN ASIA CO.
2007/11/9
3-7 LA30
LA30 can be used in various home living beds. Its easy installation and simple structure create enjoyments for the living with comfortable sleeping environment.
Features:
Simple external structure and easy installation
Low noise
Solid structure and durable feature
Main power voltage: AC 220-240V 50Hz;AC100-120V 60Hz
Duty cycle max. 10% or 6 min. rest per hour in continuous use
Ambient temperature: +5℃ to +40℃
Standard protection level: IP20
Low electricity consumption, high thrust 4000NX2
Special safety button for sliding
Color: Black
Options:
Can add one-axis or two-axes additional actuators for elevating or tilting of bed
Can use 9V alkaline battery as spares when there are shortage of interior electricity, but only work for downward movements
Can combine with LA33 ( Max. 2 pcs) for elevating and tilting of bed
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 40 LINKAN ASIA CO.
2007/11/9
CB16Ordering Example:
LA30. 0 – 87 – 69 – 2UL – 22
LA30 Feature and Its Combination
Handset
Actuator
HB23
LA30.0 ◎
HB33 HB84
Mains Voltage(Power voltage input)
12=120V
22=220V
Cables
2EU:2P,straight,EU plug
2JP:2P,straight,JP plug
2UL:2P,straight,UL plug
2AUS:2P,straight,AUS plug
Leg stroke
48:48mm
69:69mm
74:74mm
87:87mm
Back stroke
48:48mm
69:69mm
74:74mm
87:87mm
Additional actuator(The selection of funtions of addition acutator)
0:no additional actuator
1:1 additional actuator (LA33)
2:2 additional actuators (LA33)
Actuator type LA30
&
&
HB83-00 www.linkan.com.tw
LA30.1 ◎
LA30.2 ◎
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 41 LINKAN ASIA CO.
2007/11/9
Drawing dimension:
LA30
Bed Frame Dimension
Installation Instruction
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 42 LINKAN ASIA CO.
2007/11/9
3-8 LA35
LA35 has strong housing and special outer shape with strong structure. It has complete functions and can be used in high-loaded environment. For example, dental chairs, hospital beds, sport equipment, etc.. Its applications can be widely used.
Feature:
24V permanent magnet motor
Thrust 4000N~8000N
Built-in end stop signal switches(not adjustable)
Stroke length:10cm、15cm、20cm
The outside tunnel is aluminum material; inside tunnel is stainless material with low friction and high quality.
Elegant and compact design; small installation dimension
Duty cycle: Max. 10% or 2 min./ 18min. in continuous use
Ambient temperature: +5℃ to +40℃
Color:Black
Option:
Back fixture position 0° or 90° and can choose strong-type solid tailstock
Reed switch can combine CB05、CB24、CB28
Rod eye can be groove
Protection level:IP66
Can install Hall Sensor function (Contact R & D department of LINKAN A/C first)
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 43 LINKAN ASIA CO.
2007/11/9
LA35 Ordering Example :
LA35. 3 M R – 10 – 100 – R H D
Plug ( Select plug that fit with control box )
D:DIN(Standard)
J :Jack
X:Without Plug
Back Fixture Direction (Direction Installation of actuators)
H:Horizontal
V:Vertical
A:Horizontal + Solid (800Kg)
B:Vertical + Solid (800kg)
Rod Eye Direction
R:Groove
S:Standard
Cable Length
100=100cm
150=150cm
200=200cm
Stroke
10=10cm
15=15cm
20=20cm
Reed Switch
R: As the worm wheel gear rotate one cycle, Read Switch sends out 4 signals (pulses). R can let control box to read signal and run memorizing and positioning control
Safety Nut M (Can avoid that screw on the spindle break down and then do downward movement safely)
Pitch
H:Unipolar Hall Sensor
T:Bipolar Hall Sensor
3:3 ㎜ (Large thrust type)
6:6 ㎜ (Fast type)
Actuator LA35 Standard type
Back Fixture Direction(The direction of Actuator installation):
V type (Vertical install) H type (Horizontal install)
Rod Eye Type﹕(Front Install Head) Option of additional accessory "R "is “Groove" type
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 44 LINKAN ASIA CO.
2007/11/9
Dimension: Installation Dimensions:
If LA35 stroke > 100mm, basic installation dimension is S + 173 mm
LA35 Installation Dimension
Actuator Stroke mm 100 150 200
Basic Installation Stroke mm 288
Stretch Stroke mm 388
※200mm above stroke need to discuss with technical department of LINKAN A/S
Data & Graph:
323
473
373
573
Spindle type
LA35.3
LA35.3
LA35.6
Spindle Pitch
(mm)
3
3
6
Max Load
【N】
Amp. Speed【mm/s】
Push Pull Full Load Unloaded Full load
8000 4000 4.8A 4.5 3
8000 4000
4000 4000
4.8A
4.6A
6
9.3
4.5
5.7
Max.
Self lock 【N】
Push
8000
8000
4000
Voltage
DC24V
DC30V
DC24V
LA35.6 6 4000 4000 4.6A 12 8 4000 DC30V
(Duty cycle:10% )
※ The data above is based on the test of the power supply. If you need the data with compatible control boxes, please contact LINKAN A/C technical department.
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 45 LINKAN ASIA CO.
2007/11/9
POWRE SUPPLY DC33V POWRE SUPPLY DC24V
LA35.3 LA35.3
LOAD(kg) A SPEED(mm/s) LOAD(kg)
0
200
0.5
1.8
6
5.7
0
200
400
600
800
2.7
3.8
4.8
5.4
5.2
4.5
400
600
800
A SPEED(mm/s)
0.5
1.8
4.5
4
2.7
3.8
4.8
3.6
3.4
3
POWRE SUPPLY DC33V POWRE SUPPLY DC24V
LA35.6 LA35.6
LOAD(kg) A SPEED(mm/s) LOAD(kg)
0 0.5 12 0
200
400
2.7
4.6
10.3
8
200
400
A
0.5
2.9
5
SPEED(mm/s)
9.3
7.5
5.7
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 46 LINKAN ASIA CO.
2007/11/9
4 Control Box
4-1 CB02
CB02 can operate up to 3 actuators. The simple compact and elegant design makes the control box ideal for use in beds, chairs, tables and other applications; it has remote control function and the competitive price.
Features:
Connecting up to 3 actuators. Actuator type: LA31, LA32, LA33 (with Jack Plug)
Compatible with HB8X, HB3X, FS, FLS series
Elegant design
Power indicator light
Mains voltage: 220-240/ 100-120V AC; 50-60HZ
Output voltage: 24V DC
8 PIN DIN-plug for handset
1.8m straight cable
Duty cycle: Max. 5% or 3 min./ 1 hour in continuous use
Ambient temperature: +5℃ to +40℃
Protection class: IP51
Color: black
Remote control
Options:
Protection class: IP66
Color: Gray-White(Min. order 1,000pcs)
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 47 LINKAN ASIA CO.
2007/11/9
CB02 Ordering Example:
CB02 S. 3 – 2EU – 22
MAINS VOLTAGE (Input Mains Voltage)
10=100V
11=110V
12=120V
22=220V
COLOR
–:Black
+:Gray-white
CABLES
2EU:2P, STRAIGHT, EU CABLE
2JP:2P, STRAIGHT, JP CABLE
2UL:2P, STRAIGHT, UL CABLE
2AUS:2P, STRAIGHT, AUS CABLE
NO. OF CHANNELS (The No. of Actuator)
1:1 CHANNEL
2:2 CHANNELS
3:3 CHANNELS
FUNCTION
S:STANDARD
B:BASIC
CONTROL BOX TYPE CB02-STANDARD
(Plugs on CB02 are Jack Plug)
Dimensions:
Notice:
★ CB02 only can control Max. 2 actuators when using HB63R & S remote control function. Ex.
CB02S..2-2EU-22
★ CB02 has to be used with actuators with Jack Plug.
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 48 LINKAN ASIA CO.
2007/11/9
4-2 CB05 Transformer TR05
The new CB05 is a very compact design with easy installation in various applications, particularly for dental chair, gynecological table and beauty chair. This design consists of two parts: a controller
CB05 and an independent exterior power supply TR05. It is compatible with low voltage electrical components, through AC 29V mains cable.
Features:
Connected with up to 2 actuators: LA31, LA32; required to connect with DIN-plug
3 memory positions
Over load protection
Independent and compact power supply (transformer) TR05, only requiring min. power consumption with low EMC
Special interface technology and assistant device for high stability to prevent shut down or memory lost.
Can combine with HB8X, HB3X and FS series to use FLS.
Mains voltage: 220-240/ 100-120V AC; 50-60Hz
TR05 has a temperature fuse; fuse not for exchangeable
Duty cycle: Max. 10% or 6 min./ 1 hour in continuous use
Ambient temperature: +5℃ to +40℃
Protection Class: IP51
Color: black
Options:
Release function: Actuator back to original position
Return Function: Actuator back to previous position
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 49 LINKAN ASIA CO.
2007/11/9
CB05 Ordering Example:
CB05. 1 - A
TR05 Ordering Example:
TR05 – 2UL - 12
FUNCTION
A: RELEASE (Actuator back to original position)
B: RETURN (Actuator back to previous position)
NO. OF CHANNELS
1:1 CHANNELS
2:2 CHANNELS
CONTROL BOX TYPE CB05-STANDARD
(Plugs on CB05 are Din Plug)
MAINS VOLTAGE
10=100V
11=110V
12=120V
22=220V
CABLES
2EU:2P, STRAIGHT, EU CABLE
2JP:2P, STRAIGHT, JP CABLE
2UL:2P, STRAIGHT, UL CABLE
2AUS:2P, STRAIGHT, AUS CABLE
EXTERIOR POWER SUPPLY TYPE TR05-STANDARD
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 50 LINKAN ASIA CO.
2007/11/9
Dimensions (Control Box CB05):
5 6
2 8
5 . 5
8
1
6
1
6
1 0 6
9 4
Dimensions (Transformer TR05):
Notice:
★ nly used with LA31 and LA32 actuator with built-in reed switch R.
★ CB05 is only used with actuator with Din Plug
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 51 LINKAN ASIA CO.
2007/11/9
4-3 CB12
CB12 is a low voltage control box with advanced technology. CB12 can control up to 3~4 actuators.
A series of built-in safety and other options makes it ideal for the applications with both manual and electrical operation.
Features:
Max. for 3~4 actuators:. Actuator type: LA36、LA37 (with Jack plug)
Mains voltage: 220-240/ 100-120V AC; 50-60Hz
Dual output voltage (Low load: Low voltage; High load: High voltage)
Compact high power toroidal transformer ensures low power consumption and low electromagnetic emission
Electronic overload protection (EOP) common for all channels
DIN socket for handset HB8X, ACP or FS, FLS
Exchangeable mains cable
Duty cycle: Max. 10% or 6 min./ 1 hour in continuous use
Ambient temperature: +5℃ to +40℃
Protection class: IP54
Color: black
Options:
Class 1: earth connection
Mains fuse can be replaced from the out-side
Protection class: IP66
Built-in T-cable device needed for operating two handsets simultaneously
Battery back-up: battery sets (BA16)
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 52 LINKAN ASIA CO.
2007/11/9
CB12 Ordering Example:
CB12. 3 E F – 2EU – 22 B
Dimensions:
BATTERY CHARGER
MAINS VOLTAGE (Input Mains Voltage)
10=100V
11=110V
12=120V
22=220V
CABLES
2EU:2P, STRAIGHT, EU CABLE
2JP:2P, STRAIGHT, JP CABLE
2UL:2P, STRAIGHT, UL CABLE
2AUS:2P, STRAIGHT, AUS CABLE
3EU:3P, STRAIGHT, EU CABLE
3UL:3P, STRAIGHT, UL CABLE
3UK:3P, STRAIGHT, UK CABLE
3AUS:3P, STRAIGHT, AUS CABLE
MAINS FUSE F
EARTH CONNECTION E
NO. OF CHANNELS
1:1 CHANNEL
2:2 CHANNELS
3:3 CHANNELS
4:4 CHANNELS
CONTROL BOX TYPE CB12-STANDARD
(Plugs on CB12 are Jack Plug)
Notice:
★ Only used with LA36, LA37 actuators with Jack Plug
★ Built-in T-cable device needed when operating two handsets simultaneously or one handset and one ACP simultaneously
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 53 LINKAN ASIA CO.
2007/11/9
4-4 CB16
CB16 is a low voltage control box that can control up to 4 actuators. A series of built-in safety and other options makes it ideal for vast medical and industrial applications.
Features:
Max. for 4 actuators. Actuator type: LA31, LA32, LA33 (with Jack Plug)
Mains voltage: 220-240/ 100-120V AC; 50-60Hz
Dual output voltage (Low load: Low voltage; High load: High voltage)
Compact high power toroidal transformer ensures low power consumption and low electromagnetic emission
Electronic overload protection (EOP) common for all channels
DIN socket for handset HB8X, HB3X, ACP or FS
Exchangeable mains cable
Duty cycle: Max. 10% or 6 min./ 1 hour in continuous use
Ambient temperature: +5℃ to +40℃
Protection class: IP54
Color: Black
Can be mounted with BA16
Options:
Battery back-up: battery sets (BA16)
Battery alarm indicates low battery charge with a buzzer
Class 1: earth connection
Mains fuse can be replaced from the out-side
Protection class: IP66
Built-in T-cable device for operating two handsets simultaneously
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 54 LINKAN ASIA CO.
2007/11/9
CB16 Ordering Example:
CB16. 3 E F – 2UL – 22 B
BATTERY CHARGER
B:BATTERY CHARGER
T:TRANSFORMER
MAIN VOLTAGE (Input mains voltage)
10=100V
11=110V
12=120V
22=220V
CABLES
2EU:2P, STRAIGHT, EU CABLE
2JP:2P, STRAIGHT, JP CABLE
2UL:2P, STRAIGHT, UL CABLE
2AUS:2P, STRAIGHT, AUS CABLE
3EU:3P, STRAIGHT, EU CABLE
3UL:3P, STRAIGHT, UL CABLE
3UK:3P, STRAIGHT, UK CABLE
3AUS:3P, STRAIGHT, AUS CABLE
MAINS FUSE F
EARTH CONNECTION E
NO. OF CHANNELS
1:1 CHANNEL
2:2 CHANNELS
3:3 CHANNELS
4:4 CHANNELS
CONTROL BOX TYPE CB16-STANDARD
(Plugs on CB16 are Jack Plug)
Dimensions:
CB16
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 55 LINKAN ASIA CO.
2007/11/9
BA16
CB16 combined with BA16
Combined dimensions:
Notice:
★ CB16 has to use actuators with Jack Plug, such as, LA31, LA32, and LA33.
★ Built-in T-Cable device needed when operating two handsets simultaneously or one handset and one ACP simultaneously.
★ BA16 consists of 2 pcs DC12V 1.2Ah batteries
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 56 LINKAN ASIA CO.
2007/11/9
4-5 CB22
CB22 is a special controller for reverse beds; it has low voltage feature and can control up to 4 actuators. A series of built-in safety and other options makes it ideal for vast medical and rehabilitation applications.
Features:
Connection for up to 4 actuators. Actuator type: LA31、LA32 (Jack-Plug)
Mains voltage: 220-240/ 100-120V AC; 50-60Hz
Dual output voltage (Low load: Low voltage; High load: High voltage)
Compact high power toroidal transformer ensures low power consumption and low electromagnetic emission
Electronic overload protection (EOP) common for all channels
Special interface technology and assistant device to ensure high stability and prevent shutting down or memory lost.
Operational indicator light and warming buzzer largely increases the safety during working.
Advanced technology, automatic sleeping & wake-up device and low power consumption ensure long time operation while power is off
DIN Plug socket for handset HB8X, ACP or FS
Exchangeable mains cable
Duty cycle: Max. 10% or 6 min./ 1 hour in continuous use
Ambient temperature: +5℃ to +40℃
Protection class: IP54
Color: Black
Can be mounted with BA16
Options:
Transmitter for reverse beds
Mains fuse can be replaced from the outside
Battery back-up: BA16; audio battery alarm indicates low battery charge
Protection class IP66
Class 1: Earth connection
Built-in T-cable device needed for operating two handsets simultaneously
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 57 LINKAN ASIA CO.
2007/11/9
CB22 Ordering Example:
CB22 R . 3 E F – 2UL – 22 B
Dimensions:
CB22
BATTERY CHARGER
B:BATTERY CHARGER
MAINS VOLTAGE
CABLES
10=100V
11=110V
12=120V
22=220V
2EU:2P, STRAIGHT, EU CABLE
2JP:2P, STRAIGHT, JP CABLE
2UL:2P, STRAIGHT, UL CABLE
2AUS:2P, STRAIGHT, AUS CABLE
3EU:3P, STRAIGHT, EU CABLE
3UL:3P, STRAIGHT, UL CABLE
3UK:3P, STRAIGHT, UK CABLE
3AUS:3P, STRAIGHT, AUS CABLE
MAINS FUSE F
EARTH CONNECTION E
NO. OF CHANNELS
1:1 CHANNEL
2:2 CHANNELS
3:3 CHANNELS
4:4 CHANNELS
FUNCTION
R:TILTING (Reverse Bed)
CONTROL BOX TYPE CB22-STANDARD
(Plugs on CB22 are Jack Plug)
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 58 LINKAN ASIA CO.
2007/11/9
BA16
CB22 combine with BA16
Combined dimensions:
Notice:
★ Only for reverse beds system. Actuators for reverse function need 100mm stroke. In addition,
CB22 has to use transmitter simultaneously
★ Only used with LA31 and LA32 actuators with Jack Plug.
★ BA16 consists of 2 pcs DC12V, 1.2Ah batteries
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 59 LINKAN ASIA CO.
2007/11/9
4-6 CB07
CB07 is a low voltage operated controller for max. 3~4 actuators. The high power toroidal transformer and special circuit design makes CB07 ideal with LA37.
Features:
Max. for 3~4 actuators ( Depend on different type of actuator )
Mains voltage: 220V~240V/100~120V AC;50/60 Hz
Compact high power toroidal transformer ensures low power consumption and low electromagnetic emission
DIN socket for handset HB8X、HB3X、ACP or FS
Exchangeable mains cable
Duty cycle: Max. 10% or 6 min./ 1hour in continuous use
Ambient temperature : +5℃ to +40℃
Protection class:IP51
Color:Black
Options:
Class 1: earth connection
Mains fuse can be replaced from the outside
Protection Class:IP66
Color: Gray-White (Min. Order: 1,000 pcs)
T-cable device needed when operating two handsets simultaneously
N for the use of LA31、LA32、LA33
S for the use of LA37
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 60 LINKAN ASIA CO.
2007/11/9
CB07 Ordering Example:
CB07. 3 E F – 2EU – 22 S
FUNCTION
N:For LA31, LA32, LA33
S: For LA37
MAINS VOLTAGE
10=100V
11=110V
12=120V
22=220V
COLOUR
—:Black
+:Gray-white
CABLES
2EU:2P, STRAIGHT, EU CABLE
2JP:2P, STRAIGHT, JP CABLE
2UK:2P, STRAIGHT, UK CABLE
2UL:2P, STRAIGHT, UL CABLE
2AUS:2P, STRAIGHT, AUS CABLE
3EU:3P, STRAIGHT, EU CABLE
3UL:3P, STRAIGHT, UL CABLE
3IN:3P, STRAIGHT, IN CABLE
3UK:3P, STRAIGHT, UK CABLE
3AUS:3P, STRAIGHT, AUS CABLE
MAINS FUSE F
EARTH CONNECTION E
NO. OF CHANNELS
1:1 CHANNEL
2:2 CHANNELS
3:3 CHANNELS
CONTROL BOX TYPE CB07-STANDARD
(Plugs on CB07 are Jack Plug)
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 61 LINKAN ASIA CO.
2007/11/9
Dimensions:
Notice:
★ Only used with actuators with Jack Cable.
★ Can not used with ACP simultaneously
★ Can not use battery
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 62 LINKAN ASIA CO.
2007/11/9
4-7 CB06
CB06 can operate up to 3 actuators. It has the feature of being mounted with LA33. It has elegant design suitable for the use of beds, chairs, and tables. It is suitable for being installed in less-spaced place and device of single function. It also has features of cheaper price.
Features:
Max. for 3 actuators. Actuator type: LA33
Can combine with HB8X、HB3X and FS series to use FLS
Elegant design
Power indicator light
Mains voltage: 220-240/ 100-120V AC; 50-60HZ
Output voltage: 24V DC
8 PIN DIN-plug for handset
1.8m straight power cable
Duty cycle: Max . 5% or 3 min./ 1 hour in continuous use
Ambient temperature: +5℃ to +40℃
Protection class: IP51
Color: Black
Options:
Protection class: IP54
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 63 LINKAN ASIA CO.
2007/11/9
CB06 Ordering Example:
CB06 . 1 – 2EU – 22
Dimensions:
MAINS VOLTAGE (Input Mains Voltage)
10=100V
12=120V
22=230V
CABLES
2EU:2P, STRAIGHT, EU CABLE
2JP:2P, STRAIGHT, JP CABLE
2UL:2P, STRAIGHT, UL CABLE
2UK:2P, STRAIGHT, UK CABLE
2AUS:2, STRAIGHT, AUS CABLE
NO. OF CHANNELS (The No. of actuator)
1:1 CHANNEL
2:2 CHANNELS
3:3 CHANNELS
CONTROL BOX TYPE 06- STANDARD
(Plugs on CB06 are T-Din Jack Plug)
CB06
LA33
Notice:
★ CB06 must be used with actuators with T-Din Jack Plug and 90° Din handset
★ 9V battery must use Alkaline battery
★ The design of 9Vbattery is designed to operate back, foot and the move down of the bed when electricity shortage happen.
★ Battery can not be long-term put in the control box to avoid running out of electricity or the leak of electrolyte to damage control box.
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 64 LINKAN ASIA CO.
2007/11/9
4-8 CB09
CB09 is a low voltage operated controller for max. 4 actuators. A series of built-in safety and other options makes it ideal for vast medical and industrial applications.
Features :
Max. for 4 actuators. Actuator type: LA31、 LA32、 LA33 (with DIN Plug)
Mains voltage: 220-240/ 100-120V AC; 50-60Hz
Dual output voltage (Low load: Low voltage; High load: High voltage)
Compact high power toroidal transformer ensures low power consumption and low electromagnetic emission
Electronic overload protection (EOP) common for all channels
DIN socket for handset HB8X、 HB3X、 ACP or FS
Exchangeable mains cable
Duty cycle: Max. 10% or 6 min./ 1 hour in continuous use
Ambient temperature: +5℃ to +40℃
Protection class: IP54
Color: Black
Can be mounted with BA16
Options :
Battery back-up: battery sets (BA16)
Battery alarm indicates low battery charge with a buzzer
Class 1: earth connection
Mains fuse can be replaced from the out-side
Protection class: IP66
T-cable device for operating two handsets simultaneously
Color: Gray-White (Min. order 1,000 pcs)
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 65 LINKAN ASIA CO.
2007/11/9
CB09 Ordering Example:
CB09 H. 3 E – 2UL – 22 B
BATTERY CHAEGER
B:BATTERY CHARGER
T:TRANSFORMER
MAIN VOLTAGE
10=100V
12=120V
22=230V
COLOR
+:Gray-white
-:Black
CABLES
2EU:2P,STRAIGHT,EU CABLE
2JP:2P,STRAIGHT,JP CABLE
2UL:2P,STRAIGHT,UL CABLE
2UK:2P,STRAIGHT,UK CABLE
2AUS:2P,STRAIGHT,AUS CABLE
3EU:3P,STRAIGHT,EU CABLE
3IN: 3P,STRAIGHT,IN CABLE
3UL:3P,STRAIGHT,UL CABLE
3UK:3P,STRAIGHT,UK CABLE
3AUS:3P,STRAIGHT,AUS CABLE
EARTH CONNECTION E
NO. OF CHANNELS
1:1 CHANNEL
2:2 CHANNELS
3:3 CHANNELS
4:4 CHANNELS
HIGH POWER H(Suitable for heavy load or the simultaneous movement of two axes actuators)
CB09 Dimensions::
CONTROL BOX TYPE CB09-STANDARD
(Plugs on CB09 are DIN Plug)
Notice:
CB09 has to use actuators with DIN Plug, such as, LA31, LA32, LA33.
T-Cable device needed when operating two handsets simultaneously or one handset and one ACP simultaneously.
BA16 consists of 2 pcs DC12V, 1.2Ah batteries.
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 66 LINKAN ASIA CO.
2007/11/9
4-9 CB28 Control Box for dental chair
CB28 is a controlling system for dental chairs. Its multi-functional controlling board with steplessmemorizing feature will make users easy to proceed output and input instructions by their requirements.
This makes CB28 ideal for the system of dental chairs.
Feature
Control max. 2 actuators and controlling board (Rinse basin, water refilling, water heating, X-ray light, light for mouth)
Multi-functional operating system with simplicity and convenience
Mains voltage: 220~240V / 100~ 120V, 50/60 HZ
High power, low electricity consumption, and low radiation provided by Built-in EI transformer
Easy to change for external fuse
Three-points memorizing function, positions for gargling, and the returning function
Emergency safety lock
Clear indicator light with warning sound
Ambient temperature: +5°C ~ + 40°C
Duty cycle: Max.10% or 2 min. / 18 min. in continuous use
Protection class: IP54
Color: Black
Option
Protection class: IP66
Customized requirement for the adjustment of input and output function
Color: Gray White
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 67 LINKAN ASIA CO.
2007/11/9
Manual Guide
一
.
Seat Movement control UP SET
1.Manual Control
Press”UP”: Seat upward; Release “UP”: Stop moving
Press “DN”: Seat downward; Release “DN”: Stop moving
Press “BU”: Seat forward; Release “BU”: Stop moving
BD BU
DN
Press “BD”: Seat backward; Release “BD”: Stop moving
2. Foot Switch Control:
Pic.1 Main Operating board (Manual Height and Tilting Control)
Functions from four buttons of foot switch are the same with main operating board above.
二、Memory positioning Control
Please finish setting up parameter first before proceeding automatic control. Please refer to each parameter setting.
SET LP P1 P2 P3
1. Pre-set memory button control.
RSET Pic.2 Main operating board (Memory position control)
Press one of the keys (P1 P2 P3) and the seat will move to pre-set position automatically.
2. Returning (Reset) button control
Press Reset button .The seat will move down to the lowest position and the seat back will move up to the highest position
2. Gargling position control
The back will move up to the highest position when pressing gargling button. If press once again when proceeding, the seat will stop moving. Then press once again, the seat back will return to original position.
If press any position button when moving, the seat will stop gargle position.
WATCH
1.Gargling refill control
HEAT
CUP
WATER LAMP
Press “Cup” and it will refill and stop according to time setting.
2.Rinse basin control
Press “Water” and it will rinse the basin and stop according to time setting.
Pic. 3 Main Operating board
(Other functions control)
3.Heating control
Press “Heat” to begin to heat. The indicator light will start to flash and stop automatically when it reaches the temperature already set. The water will be heated once again if the water temperature be down. Press “Heat” button again and it will stop heating and the indicator light will stop flashing.
4.X-Ray light control
Press “Watch” and the X-Ray light will be turned on. Press it once again, the light will be turned off.
5.Control for Light for mouth
Press “Lamp” to turn on the light for mouth. Press it once again, the light will be turned off.
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 68 LINKAN ASIA CO.
2007/11/9
Parameter setting
一、Maximum seat position setting
1.Press Set button around twenty seconds and indicator light will be turned on and flash.
Simultaneously, it will make buzzer sounds with long continuous sound.
2. Press “UP ” and “BU” buttons separately to adjust the seat and seat back to the required position.
3. Press “Set” button again, the flashing frequency of indicator light and buzzer sounds will become fast. In this time, it can start to proceed the setting of the lowest position to the seat.
4. Press “DN” and ”BD” buttons separately to adjust the seat and the seat back to the requirement position.
5. Press “Set” button and save the memory setting, the indicator light will be turned off and out of setting condition.
二、Pre-set memory button setting
1. Press “Set” button around 2 seconds and the indicator light will be turned on. Then it will enter setting condition.
2. Manual control adjusts the seat to required position.
3. Choose the required memory position and press the button. It can memorize three points (P1, P2, P3)
4. Press “Set” button and save the memory setting, the indicator light will be turned off and out of setting condition.
三、Refilling time setting
1. Press “Set” button around 2 seconds and the indicator light will be turned on and it can enter setting condition.
2. Press “Cup” button to refill up water manually according to time setting.
3. Press “Set” button once again and save the refilling setting. The indicator light will be turned off and out of setting condition.
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 69 LINKAN ASIA CO.
2007/11/9
四、Rinsing basin time setting
1. Press “Set” button around 2 seconds. The indicator light will be turned on and it enters the setting condition.
2.Start to select time of rinsing basin.
(1) Press “Water” once and the buzzer will make short sound once. It means time setting for rinsing basin is 30 minutes.
(2)Press “Water” twice and the buzzer will make short sound twice. It means time setting for rinsing basin is 60 minutes.
(3) Press “Water” three times and the buzzer will make short sound three times. It means time setting for rinsing basin is long period.
(4) Press “Water” four times and the buzzer will make short sound four times. It means time setting for rinsing basin is 12 seconds. This situation is usually applied in the testing experiments.
3. Every rinsing setting starts from 30 minutes.
4. Choose the rinsing time, then press “Set” button once again and save the memory setting. The indicator light will be turned off and out of setting condition.
5.Recommend the rinsing time should depend on sounds from buzzers when setting time. This can avoid the wrong setting.
Caution
:
1. The main operating board has 3 lights from top to bottom: Setting indicator light with green color, heating indicator light with red color, power indicator light with green color.
The secondary operating board has heating indicator light with red color and power indicator light with green color.
2. J2 connection on the main operating board is short circuit connection. It can be used in the emergency stop when all buttons are out of order.
3. CN2 connection on Foot Switch is emergency safety lock. When it is short circuit, the seat back and the seat just can move upward but not downward.
Heating light
Power light
Setting light
J2
Pic. 4 Main Operating board (Light signal & connection)
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 70 LINKAN ASIA CO.
2007/11/9
Connection Demonstration:
Power
Transferring Board
Cable1
Cable5
Transferring head
Main operating board
Accessory:
Cable2
Cable1
Cable4
Main operating board
Cable2
Cable5
Cable4
Cable3
Secondary operating board
Back actuator
Cable6
Foot Switch
Secondary operating board
Cable3
Cable6
Transferring board
Height actuator
Treatment Board
Treatment Board
Foot Switch
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 71 LINKAN ASIA CO.
2007/11/9
Control board for treatment :
N1:Control box connection port
N2: X-Ray light cable
N3:AC220V cable, heating cable
N1
N4:Cable for temperature Transmission and
monitoring
N5:Cable for water supply, rinsing, and AC220V
N2 power
N6:Control cable for light for mouth.
N3 N4 N5
Main line board
Control Box
0
0
9
9
8
8
7
7
6
6
5
5
4
4
3
3
2
2
1
1
N6
blank
Pic.5 Treatment board connection position drawing
Pic. 6 Main Controller connection position
N2:Line for X-ray light
1
2
3
4
Transformer
1
2
3
4
N2
No. 1 Main line board Lower 3
No. 1 Main line board Lower 4
No.1 Main line board Upper 5
No. 1 Main line board Upper 6
Switch
X-ray light
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 72 LINKAN ASIA CO.
2007/11/9
N3:AC220V Cable,Heating cable & N4:Cable for temperature Transmission
N3
OUT IN
Fuse
Temperature controller
Hot water bottle
Main line board Upper 0
Main line board Lower 5
Main line board Lower 6
Main line board Lower 0
N4
N5:Water supply cable,Cable for rinsing basin,AC220V Power cable
Transformer
Main line Board Upper 6
Main line board Upper 5
Water
N5
Rinsing
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 73 LINKAN ASIA CO.
2007/11/9
N6:Control cable for light for mouth
CB28
Ordering Example:
CB28 M1 - 120 - L - 1 1 1 C X X
Light for mouth
N6
Fuse
Fuse
Main line board Upper 7
Main line board Upper 8
Main line board Upper 9
Model Code
Customer Code
Nationality code
Foot Switch
0:Two axes Foot Control Switch not required
1:Foot Control Switch required
Secondary Operating Board
0:Secondary operating board not required
1:Secondary operating board required.
Main Operating Board
0:Main operating board not required
1:Main operating board required
Transfomer
L:for LA32(66VA)
M:for LA33(76VA)
H:for LA35(86VA)
N:No Transfomer
Input Voltage
120=AC120V
220=AC230V
Function Type
M1:Memory Type
E1:Simple Type
Control Box Type CB28-Standard
(Plugs on CB28 are DIN Plug)
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 74 LINKAN ASIA CO.
2007/11/9
CB28 Outer Dimension:
Main Operating Board Dimension:
58
37
22
Secondary Operating Board Dimension:
58.6
150.8
95.5
80.5
24.5
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 75 LINKAN ASIA CO.
2007/11/9
Treatment Board Dimension:
99.7
Connection Cable Dimension﹕
8P direct connection
8P direct connection
8P direct connection
6P direct connection
8P DIN male head
8P direct connection
81.2
Length 175cm
Cable1
Length 210cm
Cable2
Length 150cm
Cable3
Length 140cm
Cable4
Length 210cm
Cable5
Length 50cm
Cable6
8P DIN female head
8P direct connection
8P direct connection
5P DIN
8P DIN male head
8P DIN female head
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 76 LINKAN ASIA CO.
2007/11/9
5 Control
5-1 HB3X
HB3X is a compact design with a beautiful streamline shape. LINKAN A/C offers HB3X with protection class IP66 as standard and with function of simultaneous movement (twin action). It can be used in homecare and nursing beds and the price is very competitive.
Features:
Handset for operating up to 3 actuators
Easily operated by both left-and right-handers
Ergonomic and elegant design
Tactile TACT switches secure long lifetime
Up to 6 easy-touch buttons
Protection class: IP66
1m straight cable + 20 cm coiled cable
Hook for easy placement
Color: Black
Options:
Either control back and foot separately or simultaneously
Power indicator light
The length of coiled cable can be ordered upon customer’s needs
Straight cable 90° Din plug (for CB06 of LA30 only)
Customized front cover (Min. Order: 1,000pcs)
Color: Gray-white (Min. order: 1,000 pcs)
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 77 LINKAN ASIA CO.
2007/11/9
HB3X Ordering Example:
HB3 3 S C – C 0
FRONT COVER
0:STANDARD
1:TWIN ACTION FUNCTION
CABLES
C:COILED CABLE
S:STRAIGHT CABLE
O:WITHOUT PLUG
COLOR
–:Black
+:Gray-White
FUNCTION (Operate two actuators simultaneously)
C:TWIN ACTION FUNCTION
TYPE OF PLUG
S: 8 Pin Din (STANDARD)
B:90° Din Plug (FOR CB06 ONLY)
Dimensions:
NO. OF CHANNELS
1:1 CHANNEL
2:2 CHANNELS
3:3 CHANNELS
HANDSET TYPE HB30
58 27
27
33
&
HB 33-01
R www.linkan.com.tw
Notice:
★ Max. 6 press buttons; Can operate 3 actuators movement
★ Can be used with CB02、CB06、CB07、CB09、CB12、CB16、LA30
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 78 LINKAN ASIA CO.
2007/11/9
5-2 HB63R&S
This is a remote controller particularly for homecare beds & chairs. The streamline shape and no dead space for remote control are the most outstanding features. It is compatible with control box,
CB02S.2.
Features:
Max. 2 actuator operation
Simultaneous movement for CH1 & CH2 (Twin action function)
No dead space for remote control
Power indicator light
&
Remote controller -HB63S Receiver -HB63R
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 79 LINKAN ASIA CO.
2007/11/9
HB63R&S Options:
HB6 3 R
HB6 3 S
Illustration of installation:
R:RECEIVER
3 CHANNEL OPERATION FUNCTIONS
HANDSET TYPE
S:REMOTE CONTROLLER
3 CHANNEL BUTTONS OPERATION FUNCTIONS
HANDSET TYPE
CB02S.2
LA31
LA31
HB63R
HB63S
※HB63R is only compatible with CB02.S2 dated at Jan. 01, 2006 or later.
Notice:
★ HB63R and HB63S only can be used with CB02S. 2
★ Standard Color: Gray-White
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 80 LINKAN ASIA CO.
2007/11/9
5-3 HB8X
HB8X combines ergonomic design and functionality. LINKAN A/C offers HB8X with protection class IP54 as standard and a series of function such as memory and simultaneous movement.
Features:
Handset for operating up to 4 actuators
Easily operated by both left-and right-handers
Ergonomic and elegant design
Tactile SMD switches secure long lifetime
Protection class: IP54
0.6m coiled cable
Up to 10-easy touch buttons
Easy to disassemble and repair
Hook for easy placement
Color: Black
Can used with ACP handset
Options:
Memory function
Parallel drive: up to 4 actuators
Color: Gray-white
Front and back inclination function
Left and right inclination function
S straight cable
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 81 LINKAN ASIA CO.
2007/11/9
HB8X Ordering Example:
HB8 3 – C 0
FRONT COVER
0:STANDARD
1:TRENDELENBURG FOR CB16
2:TRENDELENBURG FOR CB24
CABLE
3:TILTING (REVERSE BED) FOR CB22R
4:MEMORY FOR CB05
C:COILED CABLE
S:STRAIGHT CABLE
0:WITHOUT PLUG
COLOR
–:Black
+:Gray-white
NO. OF CHANNELS
1:1 CHANNEL
2:2 CHANNELS
3:3 CHANNELS
4:4 CHANNELS
5:5 CHANNELS
Dimensions:
HANDSET TYPE HB80
6 6 1 2
4
1
2 7
3 3
&
HB83-00 www.linkan.com.tw
Notice:
★ Max. 10 press buttons. Can operate 4 actuators
★ Can used with ACP handset
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 82 LINKAN ASIA CO.
2007/11/9
5-4 FS
LINKAN A/C Foot Switch is designed and developed for LINKAN A/C controller. LINKAN A/C
Foot Switch is designed to control hospital beds, obstetric tables, rehabilitation beds, beauty salon chairs, etc.
For user’s convenience, 4-set control is designed on one Foot Switch. It is easier and more accurate for operation.
Features:
Streamline shape and ergonomic design.
Compatible with LINKAN A/C controller CB02, CB05
, CB06, CB09, CB12 and CB16
Up to two-channel control.
Protection class: IP45
Switch Functions:
FS
UP DN BU BD
CH
CH1-UP ◎
CH1-DN ◎
CH2-UP ◎
CH2-DN ◎
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 83 LINKAN ASIA CO.
2007/11/9
FS Ordering Example:
FS– 2
Switch Function
1–1 CH
2–2 CH
FS:Foot Switch
Dimensions
&
Notice:
Max. operate 2 actuators.
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 84 LINKAN ASIA CO.
2007/11/9
5-5 FLS
The single axle Foot Limit Switch (FLS) is developed for operating in coordination with LINKAN A/C controller. FLS can be used on hospital beds, gynecological table, beauty salon chairs, operating tables, etc.
Features:
Simple and practical design.
Protection class: IP 66
The user can control one actuator with 2 or above FLS by series connection, or control actuators with 2 or above FLS.
Endurable for impaction. With long life-span
Cheaper price
FS Ordering Example:
FLS + 3
Switch Function
0–One Axle
1–Two Axles
2–Three Axles
3–Four Axles
Color :
-Black
+Gray-white
FLS:Foot Limit Switch
Dimensions
Notice:
★ Can be used with CB02、CB05、CB06、CB07、CB09、CB12、CB16
★ Can control up to 4 actuators with 2 or above FLS by series connection
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 85 LINKAN ASIA CO.
2007/11/9
5-6 ACP
ACP (Attendant Control Panel) is designed for most electric hospital and care beds. It allows nursing staff not only to directly control the position functions, but also to lock the single function or whole position functions.
ACP is an ergonomic design and easy to install on most electrical beds. The installation position is supposed to be out of reach of the patient (such as in the foot end broad of bed). This is to prevent inappropriate or even dangerous operation to the patient and stop the handset function.
Features:
Control up to 4 channels while connecting with CB09, CB16 or CB24
Beautiful streamline shape and compact design
High-strength plastic housing protects the electronics
ACP with keyboard can be used as an extra handset
Protection class: IP51
2M straight cable
Color: Gray-white
Return to original position Function Button(This function can let all actuators return to the original position)
Can be used with HB8X series handsets simultaneously
Options:
Protection class: IP66
The length of coiled cable can be ordered for customers’ needs
If other front covers than standards are requested, customers themslves must design them. The plates designed by the customers can be executed according to their own designs including channel functions.
Customized front cover (Min. Order: 1,000 pcs)
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 86 LINKAN ASIA CO.
2007/11/9
ACP Ordering Example:
ACP 4 – S – A
FUNCTION
A:A type ACP rotating buttons lock both ACP and handset
Dimensions:
B:B type ACP rotating buttons only lock handset, pressing
HANDSET buttons on ACP still can work
S:FOR CB16
NO. OF CHANNELS
3:3 CHANNELS (Can choose A or B type ACP)
4:4 CHANNELS (Only used in A type ACP)
TYPE ACP
&
Notice:
★ Can used with CB09、CB16
★ Only control 3 axis and 4 axis actuators system
★ A type ACP: When functions of any rotating button on ACP are locked, both handsets and pressing buttons on ACP will be locked.
★ Actuators can not be equipped with break functions when they are used with ACP together
★ When batteries provide electricity, ACP did not provide function of returning original place.
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 87 LINKAN ASIA CO.
2007/11/9
5-7 HB23
HB23 is used with LA30. Its easy and simple design fit ergonomic design with beautiful sense. It is used in chairs and beds in the field of home nursing or leisure. It is very convenient.
Features:
● Well-touched button design
● 1m straight line + 20 cm coiled cable
● Not breakdown easily due to the pulling
● Useful hook design
● Hard housing material for the impact & not break easily
● Black housing for dirt -proof
● Shape with fashionable and beautiful sense
● Function of simultaneous movement
BH23 Ordering Example:
HB23 - C0
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 88 LINKAN ASIA CO.
2007/11/9
6 Miscellaneous
6-1 TRANSMITTER
Transmitter is a sensor to detect stroke length. This is designed for CB22R & LA31, LA32 system solution. It can detect the stroke length between the two fixed point.
Features:
TRANSMITTER is a accessory and designed for CB22R、LA31、LA32
Surface material is aluminum alloy
It is semi-manufactured for customers’ own installation
Dimensions:
Notice:
★ Must used with LA31, LA32 actuator with stroke 100mm
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 89 LINKAN ASIA CO.
2007/11/9
6-2 MOLR
MOLR is for LA36 & LA37. This is a mechanic overload protection device with a patent. MOLR can prevent motor from damage if user operates incorrectly. It also can be used as a general crank.
Features:
Ergonomic and simple design, the handle can be folded for easy placement
Special mechanic design with a patent, easy for users to drive motors
Dimensions:
265.00
155 00
12.00
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 90 LINKAN ASIA CO.
2007/11/9
6-3 SLS
SLS limit switch is used with actuators of LINKAN A/C. It can be applied in the structure of actuators and has dual protection functions.
Features:
Compatible with all LINKAN A/C systems
Easy installation and small size
Connected between actuators and control boxes
Protection class: IP51
Color: Gray-White
Options:
IP55 or IP56
Other specifications in the length of cable
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 91 LINKAN ASIA CO.
2007/11/9
SLS Ordering Example:
SLS. J 200 –D 100 –2
Option
0:1 × NO switch external signal unit/simple switch function
1:1 × NC switch external signal unit/simple switch function
2:1 actuator outwards direction stops when switch is activated/inwards direction is always possible
3:1 actuator inwards direction stops when switch is activated/outwards direction is always possible
4:Double switch:2 × NO switches external signal unit/simple switch function
5:Double switch:2 × NC switches external signal unit/simple switch function
6:Double switch:2 × NO switch, 1 × NC switch external signal unit/ simple switch function
Cable Length (For L2)
0: 0 cm
L2
100:100 cm
200:200 cm
Type Of Plug
D:Din
L1
J:Jack
X:Without Plug
Cable Length (For L1)
0: 0 cm
100:100 cm
200:200 cm
Type Of Plug
D:Din
J:Jack L2
Dimensions:
X:Without Plug
SLS Type SLS-Standard L1
SLS
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 92 LINKAN ASIA CO.
2007/11/9
7、Application
7-1 Medical Bed
1. Medical and Nursing Demand
From the point of hospital development demand, the treatment is not restricted in operation room, intensive care unit and emergency room. Gradually, the treatment is shifted to wards. That is, hospital bed is not only for nursing purpose. It evolves the requirement with medical functions.
Moreover, comfortable and pleasant wards gradually become new demands for patients.
2. The general requirements of global medical bed a. Higher requirement in Hi-Low and lower in basic height. b. Adjustment:Hi-Low: 360~660mm, backrest: 0°~85°,Footrest:0°~45°。 c. More steady bed frame and less space – the center of gravity should be steady, particularly no tilt when the beds are transported. d. Caster — weight load, dust protection, static electricity, the level of mobility — compatible with the balance level of bed itself. e. Energy-saving coordinated with speed required. The faulty rate (particularly for mobile stuff, which is exposed to easy damage.) f. Beds for better ergonomics
(i) For different race/ peoples in different areas.
(ii) Before: 4 pcs bed surface board – the head and foot ones are the same, the middle are 2 pcs. Now: 4 pcs are different.
(iii) Fitting the body shape, particularly the waist part.
(iv) Not sliding down
(v) Easier for cleaning & sterilization, even easy detached for repairing g. Head and foot board:Well designed with firmness and mobility assistance. Available with ACP operation and case history card. h. Side rail — 4 pieces type, collapsible type, slide-down type, 4 pieces + slide down type, combination type i. Mattress:Gas permeable, waterproof, anti bacterium, fireproof . j. Color:Replace white with warm color
3. The requirement of ICU bed and its functions:
ICU bed is used in intensive care unit. Because hospital beds are already available with some assistant treatment functions, some hospitals include the beds into the planning of intensive care unit. Therefore, those beds are different from medical beds. a. For doctor work, some emergent treatment must be applied when the patients are dying.
The most common treatment is CPR. The beds have to fulfill the requirement of CPR by laying down the patients immediately, free from time and places. b. The requirement of tilting:The brain pressure goes up/ down rapidly; the hemorrhage after giving birth; helping the circulation in orthopedics, etc. c. Trendelenburg:For special treatments such as spinal, anal anus examination sample, and nursing to the patients. d. Caster with central lock:Convenient for a nurs when transporting the bed alone. For the functions of one direction transportation and position fixed.
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 93 LINKAN ASIA CO.
2007/11/9
A. Emergency stretchers are mainly used in the emergency room. Generally speaking, the nursing beds are seldom for transportation. The second one is medical bed, third is ICU bed. Emergency stretchers are most used on transporting the patients. Therefore, several features are necessary for this device: a. Easy to push d. Sustainable for impact
Above mentioned factors are related to casters.
B. For the patients, most of the patients just temporarily stay in the stretcher. It does not require much comfortableness. Moreover, the patients do not get on/off this device often thus the smaller surface of bed is acceptable and space-saving. This is also the advantage when transporting the bed. From this point, only simple head/ foot boards and necessary safety side rail are needed. This bed does not require lower basic height.
C. In terms of functions: bed with 4 pieces (like medical bed design) is acceptable too. Usually, emergency stretcher only applies mechanical devices or gas spring on the height adjustment. b. Height adjustment and trendelenburg:
(i) Commonly available with two types: hydraulic (with foot switch) and electrical ones.
Two mechanisms are possible: with one actuator (cylinder) or two-actuator (cylinder) design.
(ii) For electric ones, it should consider the factors of the anti-crash, anti-shock function and the electricity capacity.
(iii)For hydraulic ones, it should consider the factors of energy saving, speed and oil leakage.
(iv) For two-actuator (cylinder) design, with parallel principles, it can provide Hi-Low and trendelenburg functions. The structure is simpler.
(v) One-actuator (cylinder) design requires some special mechanical design. It usually applies gas spring for trendelenburg. For this function, 2 gas springs will be used for parallel function. The gas springs should be with compressed-less or with higher lock force. If one cylinder is used, please notice that whether this Jacky can be installed horizontally.
(vi) Notice:If the crank is defined as manual operation, electrical actuator is as automatic, the gas spring will be deemed as semi-automatic. Besides, gas spring itself is CPR.
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 94 LINKAN ASIA CO.
2007/11/9
3. The requirement to hospital bed and its function:
A. The most basic requirements:Hi-low, backrest, and footrest. Medical bed must be available with hi-low function. The Hi-low request is to adjust height of the bed for patients getting off the bed and sleeping position as well as for doctor’s treatment.
B. Caster is a must. It must be available with brake function because medical beds are needed for moving around.
C. In some advanced hospitals and high labor cost countries, central lock casters are used for direction and position-fixed control.
4. Nursing Bed
A. No need for movement. Thus, this bed can be without casters, particularly for home beds.
B. The side rails are assembling option because users can take care of themselves.
C. For Backrest and footrest function, nursing beds are usually without hi-low function. However, with global aged population trend, for convenience of the aged people up and down the beds, the hi-low function is gradually becoming a must. However, the acceptable price of nursing beds is low, and its safety requirements are comparably not high, usually, hi-low function replace footrest one. The design provides Twin action. That is, the footrest is adjusted along with the movement when the backrest actuator is activated. It is mechanical structure to have backrest adjustment linked to footrest. Thus, when user adjusts backrest, his/her body does not slide down.
The other factor is users usually do not need single footrest adjustment function because they do not receive treatment.
D. The appearance of nursing beds looks more and more like home beds. They use more wood and less steel.
E. For home nursing, it’s important to easily-detaching the beds and DIY structure design. They have to be easily disassembled and shipped to families for re-assembling.
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 95 LINKAN ASIA CO.
2007/11/9
7-2Chairs
The applications of actuator in chairs are vast, from hospital to family purposes. The following are some common application examples.
1.Dental Chair:
Function: (1) Backrest
(2) Hi-Low
Requirement: (1) High speed, big thrust
(2) Memory function
(3) Foot switch
2. Gynecology table
Function: (1) Backrest
(2) Arm adjustment
(3) Hi-low
Requirement: (1) Low noise
(2)Waterproof
(3) Foot switch
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 96 LINKAN ASIA CO.
2007/11/9
3. Beauty salon chair
Function: (1) Backrest
(2) Footrest
(3) Hi-low
Requirement:(1) Low noise, high speed
(2) Low price
(3) Foot switch
4. Massage Chair
Function: (1) Beck rest
(2) Footrest
Requirement: (1) Low price
(2) Controller is not necessary
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 97 LINKAN ASIA CO.
2007/11/9
5. Electric wheel chair
Function: (1) Backrest
(2) Hi-low
(3) Rising up function
Requirement:(1) Low noise
(2) High thrust and low electricity consumption
(3) Controller is not necessary
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 98 LINKAN ASIA CO.
2007/11/9
7-3 Lifting Column
Lifting column is applied in lifting hi-low with bending force. The following are some applications:
1.Examination table
2. Gynecology table
3. Operation table
4. Ophthalmology tables
The applications as above have an important point: requested to tolerate high bending force and perform without shaking when in operation. This requirement enables LINKAN LA38 ideal for using in above products. Foot switch is also required in most of those applications.
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 99 LINKAN ASIA CO.
2007/11/9
7-4 Electrical Bed with Manual Operation
The development background of LA35、LA36 and LA37:
In Asian countries, the power supply system is usually unstable. Thus, it could be necessary to operate applications even under no electricity condition. However, battery is not environmentally friendly and only with short operational time. From the above conditions, actuator for electrical/manual use was developed.
LA35━ This actuator was improved from LA33. Even though LA35 has improved the difficulty for manual operation, this actuator still has the following problem:
A. Not easy for installation. This is due to different installation dimension of products from different manufacturers.
B. The manufacturing cost is high for its various types and difficulties for package and transportation.
C. Vulnerable to Damage when it is operated manually or the bed frame is somehow deformed thus cause faults in End Stop functions.
On the basis of above reasons, LA36 and LA37 are further developed.
LA36━A complete revolution. This idea is to separate the spindle and motor units in actuator. The advantages are as follows:
A. Easy for production due to its simple specifications and mass production.
B. Easy for transportation.
C. Strong against damage for its separate motor and spindle design. In this way, spindle part can be strengthened. The motor part will not be exposed to damage because of this simple design and structure.
D. Directly adjust manual bed to electrical bed.
The disadvantages could be encountered:
A. When spindle reaches limit, the motor need to be protected by control box cutting off electricity. Thus, this system increases the cost of controller.
B. Upon different spindles from different manufacturers, it will require different thrust from motors.
LA37━ This is a new product designed with the market feedback. It can efficiently solve the above problem/disadvantages. The more important is, this actuator is equipped with mechanical overload device. The advantages are as follows:
A. Robust structure and easy installation for various bed types.
B. With inner mechanical overload device to prevent from actuator damage when manual operation reaches limits.
C. The installation dimension can be adjusted by customers themselves.
D. Much easier when operated manually.
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 100 LINKAN ASIA CO.
2007/11/9
8 Installation
8-1 The Installation and The Usage of LA31 Q (LA32Q)
I. Choose the specification:
2. Compatible controllers: CB02、CB07、CB16、CB24
3. Compatible handsets: HB3X、HB8X
II. The installation dimensions
1. The installation dimension of LA31(LA32) with quick release is S+277
2. Effective clutch stroke =standard stroke(S) - 10mm
Ex. The dimensions and stroke length of LA31.5Q-15-200-BHJ(LA32.5Q-15-200-BHJ):
Effective clutch stroke length
150-10=140
III. Installation notice:
Fig.1
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 101 LINKAN ASIA CO.
2007/11/9
Fig.2
Fig. 3
Load Load
Fig. 4
Fig. 5
The fixed end
Please contact LINKAN technical department for any installation problem.
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 102 LINKAN ASIA CO.
2007/11/9
8-2 The Installation and Usage of LA36
I. Choose the specification:
1. LA36.4(Thrust 4000N): Lighter load. Good for the backrest, footrest position in hospital beds.
2. LA36.6(Thrust 6000N): Heavier load. Good for the high-low function of the hospital beds.
3. Compatible controller: CB12.
4. Compatible handsets: HB3X、HB8X.
II. The installation dimensions of LA36.6
162.5mm
132.5mm
174mm
12mm
III. Illustration
1. Detach the cranks on the foot board of the bed (Fig. 1):
(The foot board of the bed)
Detach the cranks
Fig. 1
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 103 LINKAN ASIA CO.
2007/11/9
2. Change the transmission shaft (Fig. 2):
Replace with the transmission shafts with proper length.
Fig.2
3. Install the mount at the foot end of the bed (Fig. 3, Fig .4)
Cross joint
Transmission shaft
Fig. 3
Mount
Fix the mount at the end of the bed
Fig. 4
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 104 LINKAN ASIA CO.
2007/11/9
1. Put LA36 on, and tighten the screw. (Fig. 5)
Tighten the screw
Fig. 4
Fig. 5
Don’t over-tighten the screw
Tighten the screw to reach the inner wall of the circle.
The nut welded on the mount
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 105 LINKAN ASIA CO.
2007/11/9
IV Notice
1. Keep the cross joint and the center of LA36 in a straight line. (Fig. 6)
Keep it in an axis The axis is oblique
Mount
Fig. 7 Fig. 6
2. The angle between the horizontal line of the cross joint and the central line of LA36 should be lower than
2 degrees. (Fig. 7):
Angle
Avoid the angle caused from the drop height
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 106 LINKAN ASIA CO.
2007/11/9
3. Keep the proper fitting length between LA36 and the transmission shaft. It cannot be too deep or too shallow. Otherwise it’ll cause noise. (Fig. 8)(Fig. 9):
To avoid the vibration and the noise caused, the proper fitting length is about 20mm~25mm
Leave the clearance to avoid the interruption caused from the vibration of motor
The swing angle
The length of the transmission shaft cannot be too long or too short
Fig. 8 Fig. 9
4. To avoid the danger, don’t put the crank into LA36 when it’s running. (Fig. 10)
To avoid the danger, don’t put the crank into LA36 when it’s running.
(Fig. 10)
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 107 LINKAN ASIA CO.
2007/11/9
8-3 CB05 USER MANUAL
1. Specification:
CB05 is a control box with inner chip, which can processes the position setting function and is compatible with LA31, LA32. For such combination, the specification is as follows:
2. Actuator:
(1) Require Actuator with Reed Switch
(2) Stroke range:100mm~250mm,Thrust:1500N~6000N
(3) Compatible with LA31-R or LA32-R Only
(4) Din Cable Only
(5) Quick Release is not compatible
(6) Max. 2 pcs of LA31-R or LA32-R
Example:
LA31.5BR-15-200-BHD (LA32.5BR-15-200-BHD)
R is a must for CB05
3. Handset:
(1) HB83-C4 for CB05.1A
(2) HB84-C4 for CB05.2A
Notice:For FS-2 or other control, details can be referred to later chapter.
2. Combination:
Example: Dental Chair
(System solution)
For Hi-low For Backrest
Backrest
Hi-low
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 108 LINKAN ASIA CO.
2007/11/9
3.
Operation and Functions:
3.1.Handset Operation :
Backrest: UP Button DOWN Button
Hi-Low: UP Button DOWN Button
2
3 R
S
Setting
&
HB84-06 www.linkan.com.tw
☆ When actuator connect control box for the first time, some faults in memory position may occur. In this case, the actuator position can be initialized as follows:
Press the backrest DOWN Button
When the actuator is retracted to the lowest position, press the button for 3 seconds then release it.
1
3
&
HB84-06 www.linkan.com.tw
2
R
S
Actuator for backrest
Press the Hi-Low DOWN Button
When the actuator is retracted to the lowest position, press the button for 3 seconds then release it.
1
3
&
HB84-06 www.linkan.com.tw
2
R
S
Actuator for Hi-Low
Initialization is done.
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 109 LINKAN ASIA CO.
2007/11/9
3.2. The Definition of Button
:
A. Actuator for Backrest
UP Button— This button is to activate the backrest position upward. Releasing this button can stop the movement. When the actuator reaches the highest position, whether press this button repeatedly or continuously, there will be no further movement.
DOWN Button— This button is to activate the backrest position downward. Releasing this button can stop the movement. When the actuator reaches the lowest position, the actuator stops. Keeping this button pressed for 3 seconds will initialize the system.
B. Actuator for Hi-Low
UP Button— This button is to activate the Hi-Low position upward. Releasing this button can stop the movement. When the actuator reaches the highest position, whether press this button repeatedly or continuously, there will be no further movement.
DOWN Button— This button is to activate the Hi-Low position downward. Releasing this button can stop the movement. When the actuator reaches the lowest position, keeping this button pressed for 3 seconds will initialize the system.
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 110 LINKAN ASIA CO.
2007/11/9
4.Common Operation Demonstration:
4.1. UP Button of Backrest:
Press, Upward / Release, Stop.
1
3
&
HB84-06 www.linkan.com.tw
2
R
S
4.2. DOWN Button of Backrest:
Press, Downward / Release, Stop.
1
3
&
HB84-06 www.linkan.com.tw
2
R
S
4.3. UP Button of Hi-Low:
Press, Upward / Release, Stop.
Backrest Upward
Backrest Downwar d
1
3
&
HB84-06 www.linkan.com.tw
2
R
S
4.4. DOWN Button of Hi-low:
Press, Downward / Release, Stop.
Hi-low Upward
1
3
&
HB84-06 www.linkan.com.tw
2
R
S
Hi-low downward
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 111 LINKAN ASIA CO.
2007/11/9
4.5. R/S Button:
There is few difference on the R/S button operation between CB05.2A and CB05.2B. The following will distinguish its operation seperately.
5. CB05.2A
(I) Press Once R/S Button. The backrest actuator will move to the highest position and Hi-
Low one will move downward to lowest position. This is automatic “Release” function as long as R/S button is pressed once. For interrupting, just press any button on the handset.
(II) Press R/S button for 3 seconds. Control box will make audio sound ‘Bi’ once. It indicates the system enters setting status. Under this status, any memory position button (1 or 2 or 3) can be pressed to set the position. When setting is finished, the control box will make 3 times of audio sound. This indicates the setting status is over. This memory position is taken as permanent one, which will not be lost due to no power supply.
(III) When entering setting status, if no memory position is pressed within 5 seconds, control box will make 3 times of audio sound. This indicates the setting status is automatically over.
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 112 LINKAN ASIA CO.
2007/11/9
6. CB05.2A Memory function operation:
1. Automatic Release function:
Press once R/S button
1
3
&
HB84-06 www.linkan.com.tw
2
R
S
Automatic Release
2. Memory position function:
Firstly, activate backrest and hi-low actuators to required position.
1
3
2
R
S
&
HB84-06 www.linkan.com.tw
Position adjustment
3. Secondly, press R/S button for 3 seconds.
CB05 makes sound “Bi”.
1
3
&
HB84-06 www.linkan.com.tw
2
R
S
)))Bi!
Press button 1 once
1
3
&
HB84-06 www.linkan.com.tw
2
R
S
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 113 LINKAN ASIA CO.
2007/11/9
10 Frequent Questions
Faults and Possible Causes and Solutions
Q1: No movement. The power indicator light of control box is off
A: 1.The power cable is loose or inner cable is broken
2. Fuse is blown
3.Transformer is burnt
4. Circuit is broken down
Q2: No Movement. The power indicator light of control box is on
A:1.Handset does not plug in well
2.Handset is broken
3.Circuit inside the control box is broken
Q3: No movement. But power indicator light of control box is on and makes Relay sound
A :1.The power cable of actuator does not plug in well
2. Circuit in the control box is broken
3. The power cable of actuator is broken
4. Actuator is broken
Q4: Some Movement. But actuator movement is not normal, for example, only upward but not downward; or move irregular
A:1.Handset is broken
2.Circuit in the control box is broken
3. Actuator is blown
Q5: Control box with battery can activate actuator with mains power supply but no movement when power is off. That is, battery cannot activate the actuator.
A :1.Battery has no electricity
2.Battery is broken
3. Circuit in the control box is broken
4. Fuse in the battery is broken
Q6: LA31.4BM or LA32.4BM actuator can be lowered, but motor rotate freely when upward
A: 1. Safety Nut device is broken.
Q7: LA31.B or LA32.B actuator can move upward and downward. But It will slide down when lifting upward.
A :1.Brake spring is broken
2.Motor is broken
Q8: Actuator only move upward, not downward or only downward, not upward
A:END STOP device is broken
Q9: When using LA31R or LA32R with CB05, Actuator will move only in a while then stop
A :1.Reed Switch is broken
2.Control box is broken
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 126 LINKAN ASIA CO.
2007/11/9
Specifications are subject to change without prior notice. It is the responsibility for the product users to determine the suitability of
LINKAN A/C products for a specific application. LINKAN A/C will be responsible for replacing/ repairing defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/ repair.
Page 127 LINKAN ASIA CO.
2007/11/9
Télécharger
Publicité