Autonics GP-S070 Instruction
Autonics GP-S070 is a 7-inch TFT color LCD graphic panel with a wide range of capabilities. It features analog touch control, data logger functionality, support for variable image libraries, and the ability to monitor multiple stations and channels simultaneously. The GP-S070 also supports various interfaces, including USB host/device, RS232C, RS422, and Ethernet, making it easy to connect to various external devices. Additionally, it offers support for several fonts, device monitoring, and easy software upgrades through the Autonics website.
Advertisement
Advertisement
GP-S070 Graphic Panel
7 inch wide screen, TFT Color LCD type
Graphic touch panel GP-S070
Features
NEW
● Adopts 7 inch wide TFT LCD for realizing
True Color with 16,777,216 colors
● Analog touch method
: Free tag arrangement than matrix touch method
● Data logger function
: Supports data gathering and backup of controller
● Supports variable image library
● Enables to monitor multi station and multi channel at the same time
● Supports several interface
: Supports USB Host/Device to high speed download and manage files
: Easy to connect various external devices with RS232C 2 ports and RS232C/RS422 multi-communication port
7 inch TFT Color LCD
● Supports several fonts: Supports window true type and several bitmap fonts (selectable)
● Device monitoring function
: Enables to monitor/control variable of connected control through communication port
● Easy S/W upgrade at website
(1) GP firmware file
(2) GP Editor (drawing program)
(3) Additional protocol
(4) Language and font, etc
● Connects printer/barcode reader: Enables to print out alarm history, to read barcode
Please read “Caution for your safety” in operation manual before using.
(K)
Timer
Manual
Visit our webwite(www.autonics.com) to download 'GP Editor user manual' or 'GP, LP user manual for communication',
'GP-S070 user manual'.
● GP Editor user manual
It describes how to write screen data, and is about related usage of GP-S070 HMI function.
● GP, LP user manual for communication
It describes connection for external devices such as PLC.
● GP-S070 user manual
It describes general information on the installation and usage of GP-S070 and system contents.
Ordering information
Model Item Series
GP-S070-T9D6
GP-S070-T9D7
Graphic panel
S series
Monitor size Display unit
7 inch
TFT Color
LCD
Color
16,777,216 color
Power supply Interface
24VDC
RS232C, RS422, USB HOST,
USB DEVICE, Ethernet
RS232C (2EA), USB HOST
USB DEVICE, Ethernet
(L)
Panel meter
(M)
Tacho/
Speed/ Pulse meter
(N)
Display unit
(O)
Sensor controller
(P)
Switching mode power supply
(Q)
Stepper motor&
Driver&Controller
(R)
Graphic/
Logic panel
(S)
Field network device
(T)
Software
(E)
Pressure sensor
(F)
Rotary encoder
(G)
Connector/
Socket
(H)
Temp.
controller
(I)
SSR/
Power controller
(J)
Counter
(A)
Photo electric sensor
(B)
Fiber optic sensor
(C)
Door/Area sensor
(D)
Proximity sensor
(U)
Other
R-17
GP-S070
Specifications
Model
Power supply
Allowable voltage range
Power consumption
LCD type
Resolution
Display area
Color
LCD view angle
Backlight
Brightness
Language
※1
GP-S070-T9D6
24VDC
90 to 110% of power supply
Max. 7.2W
7 inch TFT Color LCD
800×480 dots
152.4mm×94.44mm
16,777,216 color
Within each 50°/ 60°/ 65°/ 65°of top/bottom/left/right
White LED
Adjustable by software
English, Korean
GP-S070-T9D7
Text
Graphic drawing memory 16MB
Number of user screen 500 pages
Touch switch
• Vector font • 6×8, 8×8 ASCII character, high definition numbers
• 8×16 ASCII characters, 16×16 regional characters(1 to 8 times bigger for width, 0.5 to 5 times bigger for height)
Serial interface
USB interface
Ethernet interface
Analog touch
Asynchronous method: Each port of RS232C, RS422
Each port of RS232C, RS422
Each of USB HOST, USB Device(Version 1.1)
IEEE802.3(U), 10/100Base-T
Two ports of RS232C
Real-time controller
Battery life cycle
Insulated resistance
Ground
Noise resistance
Withstanding voltage
Vibration
Mechnical
Malfunction
RTC embedded
Approx. 3 years at 25
℃
Min. 100MΩ(at 500VDC megger)
3rd grounding(max. 100Ω)
± 0.5kV the square wave noise(pulse width: 1
㎲) by the noise simulator
500VAC 50/60Hz for a minute
0.75mm amplitude at frequency of 10 to 55Hz(for 1 min.) in each of X, Y, Z directions for 1 hour
0.5mm amplitude at frequency of 10 to 55Hz(for 1 min.) in each of X, Y, Z directions for 10 min.
Shock
Environ
-ment
Protection
Accessory
Mechanical
Malfunction
300m/s²(approx. 30G) in each of X,Y,Z directions for 3 times
100m/s²(approx. 10G) in each of X,Y,Z directions for 3 times
Ambient temperature 0 to 50 ℃, storage: -20 to 60℃
Ambient humidity 35 to 85% RH, storage: 35 to 85%RH
IP65F for front panel
Fixing bracket: 4EA, Battery(included)
Approval
Unit weight Approx. 520g
※1: Language can be customized.
※Environment resistance is rated at no freezing or condensation.
Functional description
Figure display
Numeral display
ASCII display
Time display
Alarm history
Alarm list
Comment display
Lamp
Part display
Line graph
Trend graph
Bar graph
Statistic graph
Panel meter
Touch key
Numeral input
ASCII input
System information function
Recipe function
Security function
Barcode read function
Floating alarm function
Time operation
Overlap window
Observe status function
Line, rectangle, circle, text, bitmap
Displays the designated device as numerical value.(decimal, hexadecimal, octal, binary, real number)
Displays the designated device value as ASCII character.
Displays current time or date.
Registers alarm history.
Displays generated (not backed up) alarm.
Displays the designated comment as device status or value.
Displays lamp as device status.
Displays the designated parts as device status and value.
Displays several device values with a graph of broken line.
Displays change of device value for time with a graph of broken line.
Displays a device value with a bar graph.
Displays a ratio of several device values with pie graph.
Displays a device value as panel meter.
Screen is switched, word/bit device values are set when it touched.
Configures user input value in device.
Configures user input ASCII code value in device.
Monitors/Controls GP operation from PLC.
Reads/Writes several PLC device collectively.
Only acceptable user can observe/operate important data.
Connects barcode reader, read barcode.
Warning message is floated when alarm is generated.
Specific bit device is ON/OFF for designated day and time.
Available to form dynamically overlapping another base screen on the base one.
Changes PLC device status/value of PLC when trigger is generated.
R-18
Graphic Panel
Dimensions
Part description
185
194
LCD Screen
Fixing bracket
(2 slots is in upper side, 2 slot is in lower side)
6.5
● Panel cut-out
Min. 240
186
+1.1
0
28.5
+1.0 0
(unit : mm)
Max. 4-R3
(A)
Photo electric sensor
(B)
Fiber optic sensor
(C)
Door/Area sensor
※Panel thickness
: Max. 4mm
● Fixing bracket
15
M4 BOLT
(D)
Proximity sensor
(E)
Pressure sensor
(F)
Rotary encoder
(G)
Connector/
Socket
(H)
Temp.
controller
(I)
SSR/
Power controller
(J)
Counter
Power terminal block
RS422 or
RS232C
-A
RS422 or
RS232C
-B
Ethernet
USB
Device
USB
Host
Mounting slot for bracket
● Ethernet Port: For connecting LAN cable and hub, use direct cable, and for connecting PC directly, use cross cable.
● USB Device: It is used to upload and download project (it is required to install USB driver on PC), and when connect to PC, it can be used as a USB memory (PC recognizes it as a removable disk).
● USB Host: It is used to manage data and upgrade firmware.
● RS232C, RS422 ports: For more information, refer to R-32 page and ' Serial interface' of GP/LP common features.
(K)
Timer
(L)
Panel meter
(M)
Tacho/
Speed/ Pulse meter
(N)
Display unit
(O)
Sensor controller
(P)
Switching mode power supply
(Q)
Stepper motor&
Driver&Controller
(R)
Graphic/
Logic panel
(S)
Field network device
(T)
Software
(U)
Other
R-19
GP-S070
Installation
1. Set GP-S070 in panel.
2. Set fixing brackets in 4 slots(2 slots is in upper side, 2 slots is in lower side).
(Upper side)
Mounting slot for bracket
(Lower side)
3. Tighten fixing bracket with M4 Screw driver and tightening torque is 0.3 to 0.5N
·m.
M4 Screw driver
Sold separately
Transmission cables connectable into external devices such as PLC are sold separately. (refer to the R-32 page for "GP/
LP communication cable".)
R-20
GP/LP Common Features
Serial interface
● All devices connectable into LP-S044 including PC, PLC, serial printer, barcode reader and dedicated connectors can be connected into both RS232C and RS422 ports.
● Device must be set for the port in system setting for LP-S044, LP-S070. For details, refer to "GP user manual".
● Use the dedicated communication cable for the each connected device.
(Refer to the "GP/LP communication cable" of R-32 page)
● For the method of wiring external devices of PLC, refer to "GP/LP communication manual".
Port
RS232C
RS422
3
2
1
5
4
3
2
5
4
1
D-Sub 9Pin
Male
D-Sub 9Pin
Female
6
7
8
9
9
8
7
6
4
5
2
3
6
7
9
1
7
8
8
9
4
5
6
2
3
NO. Pin(GP-S044, GP-S057, GP-S070)
1 Non-used
RXD
TXD
DTR
SG
DSR
Non-used
Non-used
Non-used
TXD+
RXD+
Non-used
Non-used
SG
TXD-
RXD-
Non-used
Non-used
Pin(LP-S044, LP-S070)
Non-used
RXD
TXD
DTR
SG
DSR
Non-used
Non-used
Non-used
TXD+
RXD+
Non-used
Non-used
SG
TXD-
RXD-
Non-used
Non-used
(D)
Proximity sensor
(A)
Photo electric sensor
(B)
Fiber optic sensor
(C)
Door/Area sensor
(E)
Pressure sensor
(F)
Rotary encoder
(G)
Connector/
Socket
(H)
Temp.
controller
(I)
SSR/
Power controller
(J)
Counter
Power wiring
● For power supply, use the wire of which cross section is at least 0.75mm² and use the wire of which cross section is at least 1.25mm² for grounding.
● Use crimp-on type terminal with at least 3mm of internal diameter and less than
6mm of external diameter.
● Do not apply power before power line connection.
● Check power polarity.
● Tighten the terminal screw with 0.5 to 0.8N·m torque.
● Ground resistance should be less than 100Ω and ground it separately.
Battery replacement
Please contact out distributor to replace battery.
It may cause an explosion or a fire when improper battery is used.
Caution for using
Use communication cable after checking whether there is break, short.
Please install power switch or circuit-breaker in order to cut power supply off.
Separate this unit from high voltage line, power line to avoid inductive noise.
Do not use this product at below places.
Place where there is severe vibration or impact
Place where dust exists, or corrosion causing environments.
Place where strong magnetic field or electric noise are generated
Place where is temperature/humidity is beyond the specification
Place where strong alkalis or vibration or impact
Place where there are direct ray of the sun
Installation environment
It shall be used indoor.
Altitude Max. 2,000m
Pollution Degree 2
Installation Category Ⅱ
+ -
F.G.
+ -
24VDC
(K)
Timer
(L)
Panel meter
(M)
Tacho/
Speed/ Pulse meter
(N)
Display unit
(O)
Sensor controller
(P)
Switching mode power supply
(Q)
Stepper motor&
Driver&Controller
(R)
Graphic/
Logic panel
(S)
Field network device
(T)
Software
(U)
Other
R-31
General Features
GP(Graphic Panel)? Advantages of using GP
Complicated environment of operation and control
It graphicalizes mechanical control components such as button, switch and lamps so that saves cost and space and improves the preservation of devices.
GP-S044
GP-S057
GP-S070
Graphic panel is HMI(Human Machine Interface) device that parameter monitors or changes via graphic interface by communication with PLC, temperature controller or other control units.
Graphic interface of GP is very effective to indicate value or status of parameter with visual interface that enables the communication between controller and user.
GP is able to monitor parameters virtually with LCD screen, switch screen by touching screen, set or change parameters. GP connecting with controller via serial communication method translates data and displays various control parameters with graphic.
For example, in case of the target of parameters is the temperate, the numerical value of temperature is shown with a tag and the change in temperature for time can be graphed on the screen.
Preparation for using GP
Control part
GP-S044
Control part GP-S044
Setting and change of production process
It graphicalizes mechanical control components such as button, switch and lamps so that saves cost and space and improves the preservation of devices.
Alarm alert,
Preservation of history
Alarm is occurred.
PLC
Convenient setting by user
GP-S044
It sets complicated or non-displaying controller
(Thermometer/hygrometer, temperature controller etc).
1)Temperature/Humidity without display device
RS485
The numerical value of temperature
Graph of temperature
1) GP body
2) PC
3) GP Editor
- Software for drawing GP screen
4) Manual
- GP editor user manual
- LP, GP Communication manual
- GP-S044/S057, GP-S070 user manual
5) Communication cable
- Communication cable for PC connection
- Communication cable for controller connection
6) Access devices
(PLC or controller built in communication ports)
Basic operation flow
Requirements for using GP
Install GP Editor on PC
Design data with GP Editor
<Refer to GP editer user manual>
Download display data to GP
Connection between
PC and GP body
<Refer to GP, LP communication manual>
GP connect device
<Refer to GP, LP communication manual>
Start monitoring
2)Temperature controller
#1...........#32
Easy to set and adjust parameter.
Effective data control
It prints alarm history of controller using printer. It reads the data from barcode reader and save it in PLC.
1)PLC/Printer
PLC
2)Barcode reader/PLC
GP-S044 PLC
Communication between heterogeneous controllers
PLC
RS485
Display temperature, humidity
GP-S044
GP-S044
Printer
Thermometer/ hygrometer
R-2
General Features
LP(Logic Panel)?
HMI
PLC
I/O
LP-S044 LP-S070
Logic panel is created for integrated panel in most demanding industrial environments that have been consisted of HMI, PLC and I/O. The LP through integration realizes cost down, wire reduction, space saving and enhanced user friendliness. The logic panel perfectly supports serial communication and editing display with GP
Editor and about 250 commands of SmartStudio invented on our own to edit PLC ladder/mnemonic, allowing accelerating product development and designing. And also this device can control and monitor various output devices
(sensors, button, etc) and output devices (solenoid, lamp, motor, etc) individually.
Preparations for using LP
1) LP body
2) PC
3) Software
① GP Editor
- Software for drawing LP screen
② SmartStudio
- Software for logic program
4) Manual
- GP Editor user manual
- GP,LP Communication manual
- SmartStudio user manual
- SmartStudio programming manual
- LP-S044, LP-S070 user manual
- LP series command manual
5) Communication cable
- Communication cable for PC connection
- Communication cable for controller connection
6) Access device
(PLC or controller built in communication ports)
Basic operation flow
Requirements for using LP
<Refer to GP editer user manual and SmartStudio>
Install drawing program (GP Editor) and logic program (Smart Studio) on PC
<Refer to communication manual>
Connection PC with LP body
※When LP turns on, RUN/STOP switch holds
STOP position.
<Refer to the SmartStudio programming manual>
Make Logic program with SmartStudio
Download logic data to LP body
Disconnect Smart Studio with LP body/
Connect GP Editor with LP body
(K)
Timer
Create screen or download to LP body
Test
※RUN/STOP switch holds RUN position.
(L)
Panel meter
(M)
Tacho/
Speed/ Pulse meter
(N)
Display unit
Debugging or editing program
Control or start monitoring
※
Refer to the manual for details on website(www.autonics.
com) resources.
(O)
Sensor controller
(P)
Switching mode power supply
(Q)
Stepper motor&
Driver&Controller
(R)
Graphic/
Logic panel
(S)
Field network device
(T)
Production stoppage models
& replacement
(U)
Other
(E)
Pressure sensor
(F)
Rotary encoder
(G)
Connector/
Socket
(H)
Temp.
controller
(I)
SSR/
Power controller
(J)
Counter
(A)
Photo electric sensor
(B)
Fiber optic sensor
(C)
Door/Area sensor
(D)
Proximity sensor
R-3
General Features
System configurations
Stand alone(LP Series)
Stand alone system in LP series controls a variety of I/
O without adding other devices and monitors and control operation element through direct touch of screen. (device, parameter, etc.)
PC
GP Editor
Drawing data
SmartStudio
Logic program
Download/ upload data
Run Stop
Input device
Button
Limit switch
Sensors
Other input devices
Output device
Solenoid
Lamp
Motor
Other output devices
1:1:1 configuration (GP/LP Series)
The device function makes it possible to monitor, control and the operation element (device, parameter, etc.) between different devices using two separate communication port.
PC
GP Editor
Drawing data
SmartStudio
Control program
A Controls
(PLC type)
Download/ upload data
Run
Stop
Input device
Button
Limit switch
Sensors
Other input devices
Output device
Solenoid
Lamp
Motor
Other output devices
B Controls
(Temperature controller, etc)
1:1 configuration (LP/GP Series)
The device function makes it possible to monitor the operation data (Device, parameter, etc.)
PC
GP Editor
Drawing data
SmartStudio
Control program
1:1 N configuration (GP/LP Series)
The device function makes it possible to monitor, control and the operation element (device, parameter, etc.) between different devices using two separate communication port.. In case of RS-422 port, 1:N is available only. (Up to 31 units).
Download/ upload data
Controls(PLC type)
Run Stop
Input device
Button
Limit switch
Sensors
Other input devices
Output device
Solenoid
Lamp
Motor
Other output devices
1:N configuration (LP/GP Series)
The device function makes it possible to monitor the operation element (device, parameter, etc.) by connecting in a 1:N configuration (Up to 32 units)
A Controls(PLC type)
#1..................#31
#1
PC
GP Editor
Drawing data
SmartStudio
Control program
#2
·
·
·
#31
Download/ upload data
Run Stop
Input device
Button
Limit switch
Sensors
Other input devices
Controls
(Temperature controller, etc)
Output device
Solenoid
Lamp
Motor
Other output devices
PC
GP Editor
Drawing data
SmartStudio
Control program
Download/ upload data
Run Stop
B Controls
(Temperature controller, etc)
Bar-code, printer connection
(GP/LP Series)
It can read bar-code and print a history using printer.
PC
GP Editor
Drawing data
SmartStudio
Control program
Bar-code deader
Download/ upload data
Run
Stop
Input device
Button
Limit switch
Sensors
Other input devices
Output device
Solenoid
Lamp
Motor
Other output devices
Input device
Button
Limit switch
Sensors
Other input devices
Output device
Solenoid
Lamp
Motor
Other output devices
Serial printer
R-4
General Features
Software
GP Editor(Drawing program)
● This drawing software is for GP/LP series.
● GP Editor is the software that allows creating a screen and designs a tag layout, and then transfer the data from screen to GP/LP. After download, GP/LP starts monitoring according to your screen data.
SmartStudio(Logic program)
● Logic software is for LP series.
● Support multi-project
: It is possible to open maximum 5 projects at a same time.
● Easy program editing
: Block of cell units can be edited.
Split-screen editing is available.
It provides various editing screens such as variable screen, describe screen, variable /describe screen, etc,.
● Various monitor functions
: It provides monitor functions such as variable monitor, device monitor and system monitor, time chart.
● Comfortable user interface
: It ensures easy operation with Microsoft windows layout.
● Wide range of Message windows
: It supports various message windows to edit and check program.
● Real time convert ladder to mnemonic
: Ladder and mnemonic can be written and read to edit simultaneously.
Visit our website (www.autonics.com) and download software or manuals.
< System requirements >
Item
System
Minimum requirements
IBM PC compatible computer with Intel Pentium
Ⅲ or above
Operating system Microsoft Windows 98/NT/XP/Vista/7
Memory
Hard disk
VGA
Others
256MB or more
More than 1GB of free hard disk space
1024×768 or higher resolution display
RS-232 serial port(9-pin), USB port
Manual
GP/LP common manual
● GP Editor user manual
This section describes how to make screen data and use
HMI function with GP Editor.
● Communication manual
For more information of serial connection with external devices such as PLC, refer to manual before connecting.
● GP-S044/S057, GP-S070 user manual
The manual describes installation and system organization and menus.
LP manual
● SmartStudio manual
This section describes how to install and use
SmartStudio.
● Programming manual
The manual has command and instruction.
● LP-S044, LP-S070 user manual
The manual describes installation and system organization and menus.
● LP Series instruction manual
The manual has LP installation, system configuration and instruction.
Precaution for using
Do not press touch panel with hard and sharp object.
Please store the device in the recommended temperature range, or LCD panel can be damaged.
Please check pin number shown in "Communication manual" when connect communication port
Do not block the ventilating opening of this product.
Do not use or store it in a place with direct ray of light or dust.
Do not use or store it in a place with shock or vibration.
The ground wire of GP/LP should be grounded separately.
The ground resistance should be max. 100Ω, please use the wire of min. 1.25
mm² dimension.
Please check the pin number and connect to GP/LP communication port.
Please tighten bolt on terminal block with specified tightening torque.
When liquid crystal from the broken LCD is smeared on your skin, wash it for 15 minutes. If it is gotten in your eye, wash it for 15 minutes and contact a medical specialist for more information.
Do not inflow dust or wire dregs into the unit.
For cleaning, do not use water or an oil-based detergent, use dry towels.
It should be done away regarded as an industrial waste.
(A)
Photo electric sensor
(B)
Fiber optic sensor
(C)
Door/Area sensor
(D)
Proximity sensor
(E)
Pressure sensor
(F)
Rotary encoder
(G)
Connector/
Socket
(H)
Temp.
controller
(I)
SSR/
Power controller
(J)
Counter
(K)
Timer
(L)
Panel meter
(M)
Tacho/
Speed/ Pulse meter
(N)
Display unit
(O)
Sensor controller
(P)
Switching mode power supply
(Q)
Stepper motor&
Driver&Controller
(R)
Graphic/
Logic panel
(S)
Field network device
(T)
Production stoppage models
& replacement
(U)
Other
R-5
General Features
Connectable device with GP/LP
Series
LS Master-K
LS Glofa
LS CNET
(Cnet integrated CPU)
LS CNET
(For Cnet unit)
LS XGT(For Cnet unit)
LS XGB
(Cnet integrated CPU)
LS XGB
(For Cnet unit)
OEMAX
(SAMSUNG)
OEMAX FARA
MITSUBISHI FX
MITSUBISHI Q
(For Cnet unit)
NAIS FP
SIEMENS
SIMATIC
S7-200
CPU direct connection loader ○
CPU direct connection loader ○
CPU direct connection loader ○
CPU direct connection loader ○
CPU direct connection loader ○
Cnet
Cnet
Cnet
Cnet
Cnet
Cnet
Cnet
Cnet
CPU direct connection loader ○
CPU direct connection loader ○
CPU direct connection loader ○
CPU direct connection loader ○
Cnet
Cnet
Cnet
Cnet
○
○
○
○
○
○
○
○
○
○
○
○
Cnet
Cnet
Cnet ○
CPU direct connection loader ○
○
○
CPU direct connection loader ○
CPU direct connection loader ○
CPU direct connection loader ○
CPU direct connection loader ○
CPU direct connection loader ○
CPU direct connection loader ○
Cnet ○
Cnet ○
Cnet
Cnet
Cnet
○
○
○
Cnet
Cnet
Cnet
CPU direct connection loader ○
CPU direct connection loader ○
CPU direct connection loader ○
CPU direct connection loader ○
○
○
○
CPU direct connection loader ○
CPU direct connection loader ○
CPU direct connection loader ○
CPU direct connection loader ○
CPU direct connection loader ○
CPU direct connection loader ○
CPU direct connection loader ○
CPU direct connection loader ○
CPU direct connection loader ○
CPU direct connection loader ○
CPU direct connection loader ○
CPU direct connection loader ○
CPU direct connection loader ○
CPU direct connection loader ○
CPU direct connection loader ○
XBC
N70
N70Plus
NX7
NX70
FX1S
FX1N
FX2N
FX2NC
FX3U
Q00J
Q00
Q01
Q02
Q02H
Q06H
Q12H
Q25H
FP0-C10
FP0-C14
FP0-C16
FP0-C32
FPG- C24R2
FPG- C32T
FPG- C32T2
FP0R-C10
FP0R-C14
FP0R-C1
Connectable device
MK-10S1
MK-80S
MK-120S
MK-200S
MK-300S
MK-1000S
GM4
GM6
GM7U
MK-80S
MK-120S
MK-200S
MK-80S
MK-120S
MK-200S
MK-300S
MK-1000S
XGK- PUS
XBM
XBC
XBM
FP0R-C32
FP0R-T32
FP0R-F32
CPU221
CPU222
CPU224
CPU224XP
CPU224XPsi
CPU226
Connection type GP-S057
R-6
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
GP/LP-
S044
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
GP/LP-
S070
General Features
Connectable device with GP/LP
Series Connectable device Connection type GP-S057
GP/LP-
S044
GP/LP-
S070
SIEMENS
SIMATIC
S7-300
Allen-Bradley
OMRON SYSMAC C
OMRON
Temperature controller
AUTONICS
KONICS
DELTA
DANFOSS
CPU312
CPU312C
CPU313C
CPU313C-2
CPU314
CPU314C-2
CPU315-2
CPU317-2
CPU319-3
MicroLogicx 1000
MicroLogicx 1200
MicroLogicx 1500
CPM 1A
E5AN
E5AR
E5CN
E5EN
E5ER
MT Series
MP Series
THD Series
TZ Series
TK Series
TM Series
CT Series
DS/DA Series
ARM Series
LP-S044,
LP-S070
CPU direct connection loader ○
CPU direct connection loader ○
CPU direct connection loader ○
CPU direct connection loader ○
CPU direct connection loader ○
CPU direct connection loader ○
CPU direct connection loader ○
CPU direct connection loader ○
CPU direct connection loader ○
CPU direct connection loader ○
CPU direct connection loader ○
CPU direct connection loader ○
CPU direct connection loader ○
Modbus ○
Modbus
Modbus
Modbus
○
○
○
Modbus
Private communication
Modbus
Modbus(TYPE A)
Private communication
Modbus
Modbus(TYPE A)
○
○
○
○
○
○
○
Private communication
Modbus
Modbus(TYPE A)
Modbus
Modbus(TYPE A)
Modbus
Modbus(TYPE A)
Modbus(TYPE A)
Modbus(TYPE A)
CPU
○
○
○
○
○
○
○
○
○
○
○
○
DPU Series
KRN50
Modbus
Modbus(TYPE A)
Modbus
Modbus(TYPE A)
Modbus
DTB Series
FC Series
Modbus(TYPE A)
Modbus
Modbus(TYPE A)
UNIVERSAL Modbus(Slave)
MODBUS MASTER Modbus(Master)
○
○
○
×
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
×
○
○
○
○
○
○
○
○
×
○
○
×
○
×
UNIVERSAL
MODBUS MASTER
※GP/LP connectable device list will keep updated according to the upgrade of GP Editor or additional patch. It is recommended to use the latest version of Editor.
※Applicable GP/LP firmware version is determined by GP Editor version. Whole GP system goes down if non-compatible firmware version is used.
※Visit our website (www.autonics.com) to check update of latest GP Editor and GP/LP firmware and to get more detailed instructions.
※Refer to the user manual to select proper communication cable between GP and controllers. (Sold separately)
×
○
○
○
○
○
×
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
×
○
○
○
×
○
×
○
×
○
(A)
Photo electric sensor
(B)
Fiber optic sensor
(C)
Door/Area sensor
(D)
Proximity sensor
(E)
Pressure sensor
(F)
Rotary encoder
(G)
Connector/
Socket
(H)
Temp.
controller
(I)
SSR/
Power controller
(J)
Counter
(K)
Timer
(L)
Panel meter
(M)
Tacho/
Speed/ Pulse meter
(N)
Display unit
(O)
Sensor controller
(P)
Switching mode power supply
(Q)
Stepper motor&
Driver&Controller
(R)
Graphic/
Logic panel
(S)
Field network device
(T)
Production stoppage models
& replacement
(U)
Other
R-7
Advertisement