CellLog
8S
Cell Voltage Monitor&Logger
USER’S MANUAL
SHENZHEN JUNSI ELECTRONIC CO.,LTD
Cell Voltage Monitor & Logger CellLog 8S
Thank you for purchasing the CellLog 8S. Please read the entire User‘s Manual completely and attentively as it contains a wide variety of specific programming and safety information.
Specifications
Lithium (LiPo/LiIo/LiFe) battery cell count:
Pack voltage range:
Alarm pack voltage range:
Cell voltage range:
Alarm cell voltage range:
Voltage display resolution:
Current loading of test:
Maximum voltage for alarm port:
2 – 8 series
4.0 – 43.0VDC (USB can provide lower voltage 1.0V)
0.1 – 43.0VDC
1.3 – 4.9VDC
1.3 – 4.9VDC
1mV
8mA
50VDC
Current drain for alarm port: <500mA
Log Files storage: 16Mbit (43 hours@2 seconds logging interval)
Sample logging time interval:
PC Connect:
Weight:
Dimensions (L X W X D):
0.5 –
18g
60 seconds
USB port
62X39X12mm
2.44‖X1.53‖X0.47‖
Special features
Small size with multiple functions, backlight 128*64 lattices LCD and Buzzer Tone Reminder; the interface can be operated smoothly.
CellLog 8S can not only measure 2-8S Li battery individual voltage, but also measure NiMH, NiCd, Pb battery pack voltage.
It can be set Individual Voltage Alarm and Pack Voltage Alarm, Overvoltage Alarm, Low Voltage Alarm,
Differential Voltage Alarm and Time Over Alarm. What‘s more, the extra alarm output can be linkage controlled by the users.
It has 8 sets default monitor alarm settings, which can be selected for different battery packs.
CellLog 8S has been 100% calibrated before it enters to the market, at the same time, it supports the calibration by users themselves.
The logging interval can be set by users‘ different needs. CellLog 8S has a 16Mbit flash storage, which can log offline data in 43 hours @2 seconds logging interval.
Support upgrading the hardware program by USB port. The CellLog 8S also supports the ―logview‖ software and can display, plot and analyze the charge and discharge data by it. (See detail information about logview in the following website: http://www.logview.info
)
-2-
Cell Voltage Monitor & Logger CellLog 8S
Unpack inspection
The following items are included in the package. Contact your supplier if any items are missing.
Standard items:
CDROM
CW-USB5
85
X
85mm
One copy of the User’s manual on CDROM
CW-P220
80mm
CW-C220
One Mini-USB data line
20mm
One Alarm output line
Optional items:
See details in ―Optional parts‖ (P19)
20mm
One pack voltage measurements line with clips
-3-
Cell Voltage Monitor & Logger CellLog 8S
External controls and connections
①
②
③
④
⑤
⑥
1. Input plug 2. LCD screen 3. Function button 4. USB port 5. Beep 6. Alarm port
CellLog 8S Connection Diagram
+
8
7
6
5
4
3
2
-
TYPE
HOLD
MENU
8S
7S
+
-
+
-
6S
+
5S
4S
-
+
-
+
-
3S
2S
1S
+
-
+
-
+
-
PIN 9
5
4
3
2
8
7
6
1
PIN 1
5S
4S
3S
+
-
+
-
+
-
2S
1S
+
-
+
-
PIN 9
5
4
3
2
1
8
7
6
PIN 1
BATT.
PACK
(4—43V)
+
PIN 9
5
4
3
2
1
8
7
6
PIN 1
-4-
Cell Voltage Monitor & Logger CellLog 8S
Program flow chart
CellLog
POWER ON
Logo Screen
S/N:XXXXXXXXXX
CellLog 8S
Ver X.X.X www.hillrc.com
Inf. Screen
TYPE XXXXXXXXXX
LOGS 0 RATE 2.0
[2016Kb/043h:57]
Logs OFF
⑤
Data Log
Time is shown in the upper right corner blinkingly
Transfer data to USB port
Save data to the appointed
Log File
<HOLD>
>3 Seconds
<HOLD>
>3 Seconds
①
<▢>
<▼>
Note: When you turn off the CellLog 8S it will remember the current screen and start from that screen when next turned on again.
②
12345677S 28.79
6H 4.162
1L 4.013
▣
V 149mV
<MENU>
<▢>
<▼>
>3 Seconds
1 4.013V 2 4.150V
3 4.110V 4 4.152V
5 4.087V 6 4.162V
7 4.120V 8 ------
<TYPE>
>3 Seconds
③
Main Menu
Voltage Monitor
MAIN MENU
Log Files
System...
Calibration
LOG FILE
⊙Logs OFF
○LogFile1
SYSTEM SETTING
Beep Tone
LCD Screen
ALM Output
POWER MANAGEMENT
⊙Not Save
○Backlight OFF
○Sleep Mode
Rec. Interval
Start...
Power Management
Calibration Select
CALIBRATION
⊙Default
○User Setting
<▢>
<▼>
7S 28.79V
▣
V 149mV
1 4.01
2 4.15
3 4.11
4 4.15
5 4.08
6 4.16
7 4.12
8 ----
<MENU>
>3 Seconds
Select Type
Details in Page 6
Log File Operation
LogFile1
File Select
File Empty
File Delete
.
Start Setting
File Transmit
START SETTING
Start music
Logo Screen
Inf.Screen
User Calibration
1 ------ 2 ------
3 ------ 4 ------
5 ------ 6 ------
7 ------ 8 ------
④
7S 28.79V
HV 28.80V
LV 28.78V
▣
P 0.020V
<▢>+<▼>
Search Results
Details in Page 6
Tone Setting
BEEP TONE
<MENU>
Key Tone
Hint Tone
Alarm Tone
-
■■■■■■
+
Contrast
-
■■■■■■
+
○NC.
>3 Seconds
LCD Brightness& Contrast
Brightness
ALM Output Setting
ALARM OUTPUT
⊙NO.
Record Interval
RECORD INTERVAL
(0.5-60Seconds)
2
Note:
means if no operation on the button for 1 minutes, the system will return to monitor screen automatically.
-5-
Cell Voltage Monitor & Logger CellLog 8S
③
SELECT TYPE
⊙LiPo
○Lilo
○LiFe
Select Type
LiPo
Select
Rename
Alarm
ALARM SETTING
Cells Voltag
Pack Voltage
Safety Timer
Alarm Trigger
CELLS ALARM VOLT
HV 4.22V
LV 3.00V
▣
V 500mV
Pack Alarm Voltage Setting
PACK ALARM VOLT
HV 43.00V
LV 1.000V
▣
P 42.00V
SAFETY TIMER
Minutes(1-999)
120
Alarm Trigger Select
ALARM TRIGGER
Over Voltag
Low Voltage
Difference
Time Over
<MENU>
>3 Seconds
①
<▢>+<▼>
④
<TYPE>
>3 Seconds
Voltage Monitor
<MENU>
>3 Seconds
00m:00
12345677S 28.79
6H 4.162
1L 4.013
▣
V 149mV
<▢>
<▼>
Note:
means if no operation on the button for 1 minutes, the system will return to monitor screen automatically.
Search Results
00m:00
Star t Location
1 4.013V 2 4.150V
3 4.110V 4 4.152V
5 4.087V 6 4.162V
7 4.120V 8 ------
<▢>
<▼>
7S 28.79V
▣
V
00m:00
149mV
1 4.01
2 4.15
3 4.11
4 4.15
5 4.08
6 4.16
7 4.12
8 ----
<▢>
<▼>
7S 28.79V 00m:00
HV 28.80V
LV 28.78V
▣
P 0.020V
Note: The upper right corner of the screen will alternatively blink time 00m: 00
<MENU>
50m:20 50m:20
Ending Location
50m:20
12345677S 21.79
6H 3.162
1L 3.013
▣
V 149mV
<▢>
<▼>
1 3.013V 2 3.150V
3 3.110V 4 3.152V
5 3.087V 6 3.162V
7 3.120V 8 ------
<▢>
<▼>
7S 21.79V
▣
V 149mV
1 3.01
2 3.15
3 3.11
4 3.15
5 3.08
6 3.16
7 3.12
8 ----
<▢>
<▼>
7S 21.79V 50m:20
HV 21.80V
LV 21.78V
▣
P 0.020V
Note: The upper right corner of the screen will alternatively blink ending time xxx:xx
48m:10
<MENU>
1 Low 2 ------
3 ------ 4 ------
5 ------ 6 ------
7 ------ 8 ------
Alarm time points
If there is alarm, the alarm events/alarm
time will be shown alternatively at the corresponding battery number place.
-6-
Cell Voltage Monitor & Logger CellLog 8S
Menu Operation:
1. Select the menu items by <▲> /<▼> buttons, the selected item will be shown in white.
2. Press < > to the following menu, and hold < >for more than 3 seconds, it will return to the upper menu.
Symbol Meanings:
Display Symbols The meaning of the Symbols Note
nS nH total voltage of the pack the highest individual cell voltage n:0-8, the cell count n:0-8, the highest cell number nL the lowest individual cell voltage n:0-8, the lowest cell number
▣V
HV the maximum voltage difference between the cells
▣V
= nH
- nL
The voltage maximum value
LV
▣P the voltage minimum value the pack maximum voltage difference mmM:ss
or
hhH:mm the time entering to logging
▣P = HV - LV ss:second ,mm:minute , hh: hour
⊙/○
Single choice Do/Do not
/□
Multiple choice Do/Do not
T_OVER
Safety time alarm
LOW
OVER
Low voltage alarm
Over voltage alarm
DIFF
Voltage difference alarm
Button Function
CellLog has 3 buttons, which everyone owns the first and second functions. The first function is trigger after only one click; the second function is trigger after 3 seconds holding of the button.
Press button Condition Button Function Description
<▲>
Click 1. Turns up the menu
2. Increase the value
3. Select the character input
<▼>
< >
Hold for 3 seconds
Click
Hold for 3 seconds
Click
Enter to Alarm type select menu
1. Turns down the menu
2. Decrease the value
3. Delete the character
Trigger Open/Close Logging Function
Confirmation
<▲>+<▼>
Hold for 3 seconds
Click
Enter to System Setting Menu
Check logging information
Hold for 3 seconds Save users voltage calibrated value
Note:<▲>+<▼> means pressing <▲> and <▼> at the same time.
-7-
Cell Voltage Monitor & Logger CellLog 8S
QUICK START
CellLog Power On Rec. Interval
(2 ways: one is connecting the battery through the left 9 Pin socket, the other one is through the USB port),
System self-check, and then shows the SN and version number, the display information are as below:
TYPE XXXXXXXXXX
Alarm configuration Name
Existent Log Files Number
The first line is the current selected Setting Type (See
LOGS 0 RATE :2.0
[2016Kb/35h:50]
Logs OFF
Record interval time
Free Capacity/Free Time
Current Log File Name detail in P10). The second line shows the log file number.
And the third line is the available record of capacity and time. The last line shows the current log file name (if no files, it shows "Logs OFF"). 3 seconds later, the system enters to voltage monitor status.
Voltage Monitor
There are 4 interface choices, which can be shifted by <▲> or <▼>buttons.
Pack Voltage
As the left pictures: the ‘7‘ in ‖7S‖ means cell counts; ‘6H‘ means the 6 th
cell voltage is the highest; ‘1L‘ means the 1 st
Cell Number
Voltage
Histogram
12345677S 28.79
<▢>
6H 4.162
1L 4.013
▣
V 149mV
<▼>
Cell Number
1 4.013V 2 4.150V
3 4.110V 4 4.152V
5 4.087V 6 4.162V
7 4.120V 8 ------
The highest voltage
The lowest voltage
The maximum voltage difference
Cell Voltage cell voltage is the lowest.
If the monitor voltage trigger alarm, the corresponding voltage and alarm display (LOW, OVER or DIFF) shows alternatively.
The cell number and (L, O, D) shows alternatively.
‘LOW‘ or ‗L‘ means: Low voltage alarm
Pack Voltage
Cell Number
<▢>
<▼>
7S 28.79V
▣
V 149mV
1 4.01
2 4.15
3 4.11
4 4.15
5 4.08
6 4.16
7 4.12
8 ----
The Max. Voltage difference
Cell Voltage
‘OVER‘ or ‗O‘ means: Over voltage alarm
‘DIFF‘ or ‗D‘ means: Voltage difference alarm. They will be cell voltage interface. displayed at the same time at the highest and the lowest
<▢>
<▼>
7S 28.79V
HV 28.80V
LV 28.78V
▣
P 0.020V
Pack Voltage
Max. Pack Voltage
Min. Pack Voltage
Pack Voltage Difference
Monitor the pack voltage
Display respectively: Current pack voltage, Max. Pack voltage, Min. Pack voltage, Pack voltage difference. (▣P =
HV-LV
)
Data Logging
When in Voltage Monitor status, press <▼> button for 3 seconds, after it shows ‖Start logging…‖, the calculagraph will be shown alternatively at the upper right corner of the LCD screen. In this status, the system will transmit the voltage data to USB port every X seconds( this interval time X can be set by user himself, details you can see Record Interal Time Setting in P13), and save these data to the current Log file(See
Log File Management in P12. If 【Logs OFF】, the system will not log file)
Press <▼> for 3 seconds again, the screen will show ‖Stop logging!‖ and then exit.
View Logging Point
In the monitor status, press <▲> and <▼> at the same time to enter the view logging point status.
Three points voltage data can be searched:‖Starting logging…‖data, ‖Stop logging!‖ data, and the data of voltage alarm during this period , which can be shifted by < > buttons. Press < > for 3 seconds,it will return to the monitor status.
The saved data can be covered till next logging.
If the logging time is over the users setting safety time,(See Monitor Safety Time Setting in P11), it will trigger Safety Time Alarm, and the screen shows ‖T_OVER‖ alternatively in the upper right corner.
-8-
Cell Voltage Monitor & Logger CellLog 8S
Alarm Remind
If CellLog detect the alarm events (See Alarm Trigger Settings in P11), it will remind as below:
1. The buzzer beeps every 4 seconds(【Alarm Tone】is selected , See P13).
2. The corresponding individual voltage and alarm remind show alternatively.
Alarm Remind Information: ―LOW‖, ―OVER‖, ―DIFF‖, ―T_OVER‖
3. ALM port will output the presetting signal.
ALM port signal information:
ALM output port signal is open collector signal, as showed below.
ALM Output
Q9
Please pay attention to the port voltage and current limit when you use(<50V,<500mA)
The following are ALM Output typical application.
VCC VCC
Output
R
ALM
Output
Level Output Relay Output
ALM
-9-
Cell Voltage Monitor & Logger CellLog 8S
Monitor Alarm Settings
The system can have 8 sets alarm settings, press <▲> for 3 seconds to enter SELECT TYPE menu.
SELECT TYPE
⊙LiPo
○Lilo
○LiFe
LiPo
< >
Select
Rename
Alarm
The item with is the current setting.
<▲> or <▼> to select items and press < > button.
Defaulted TYPEs are: LiPo, Lilo, LiFe, User1--5
Operate the selected type settings
<▲> or <▼> to select the items, press < > to enter to the next step.
See details below.
Note: Press<▲> button to power on, it will shift to LiPo Type automatically.
Press <▼> button to power on, it will shift to Lilo Type automatically.
Press < > button to power on, it will shift to LiFe Type automatically.
Change Current Alarm Type: Select【Select】, Press < > then the item will be with , and the settings come into effect.
Rename Alarm Type: Select【Rename】, press < > and the screen shows:
LiPo
Rename
New Name
LiPo-1200mAh
New Name Input Method: <▲> to select characters, hold it to trigger continuously; <▼> to delete the current character; < > to confirm the selected character; press < > for 2 times to confirm the amendment and return; press < > for 3 seconds to cancel and return.
Alarm Parameters Setting: Select【Alarm】, press < > and the screen shows:
ALARM SETTING
Cells Voltag
Pack Voltage
Safety Timer
Alarm Trigger
<▲> or <▼> to select items, press < > enter to the next step
See details below.
1) Individual Cell Voltage Alarm Settings: Select【Cells Voltage】, press < > and the screen shows:
CELLS ALARM VOLT
HV 4.22V
LV 3.00V
▣
V 500mV
Cell Alarm Upper Limit
Cell Alarm Lower Limit
Cell Alarm Difference
<▲> or <▼> to increase/decrease voltage value, press < > to shift setting items. Press < > for 3 seconds to confirm amendment and return.
HV
: 1.31V—4.90V LV: 1.30V—4.89V ▣V: 0.01—3.60V
2) Pack Alarm Voltage Setting: Select【Pack Voltage】, press < > and the screen shows:
PACK ALARM VOLT
<▲> or <▼> to increase/decrease voltage value, press < > to shift
HV 43.00V
LV 1.000V
▣
P 42.00V
Pack Alarm Upper Limit
Pack Alarm Lower Limit
Pack Alarm Difference setting items. Press < > for 3 seconds to confirm amendment and return.
HV
: 1.05V—43.00V LV: 1.00V—42.95V ▣P: 0.05—42.00V
-10-
Cell Voltage Monitor & Logger CellLog 8S
3) Monitor Safety Time Setting: Select【Safety Timer】, press < > and the screen shows:
SAFETY TIMER
Minutes(1-999)
120
Safety Time
<▲> or <▼> to increase/decrease, press < > to confirm amendment and return. Press< > for 3 seconds to cancel amendment and return.
Setting range: 1-999 minutes
4) Alarm Trigger Settings: Select【Alarm Trigger】, press < > and the screen shows:
<▲> or <▼> to select items, press < > to shift select /,
ALARM TRIGGER
Over Voltag
Low Voltage
Difference
Time Over press< > for 3 seconds to confirm amendment and return.
Select【Over Voltage】Cell or pack voltage are over HV setting value, then it alarms.
Select【Low Voltage】Cell or pack voltage are lower LV setting value, then it alarms.
Select【Difference】Cell voltage is over ▣V or the pack voltage difference is over ▣P setting value, then it alarms.
Select【Time Over】 entering HOLD status time is over setting safety time ,then it alarms.
-11-
Cell Voltage Monitor & Logger CellLog 8S
Parameter Setup
Press < > for 3 seconds, and enter to the MAIN MENU, Monitor status.
MAIN MENU
Log Files
System...
Calibration
Log File Management: Select【Log Files】, press < > and the screen shows:
LOG FILE
⊙Logs OFF
○LogFile1
The first item is【Logs OFF】,if it is chosen, LOG function is close.
Press <▲> for 3 seconds to create new Log files.
< >
>3 Sec
FILE CREATE
File Name:
LogFile1
The operation to the existing files:
Log file name input method:
<▲> to select characters, hold it to trigger continuously; <▼> to delete the current character; < > to confirm the selected character; press < > for 2 times to confirm the amendment and return; press< > for 3 seconds to cancel and return.
LOG FILE [01230]
Logging number the
⊙Logs OFF
○LogFile1
LogFile1
< >
File Select
File Transmit
File Empty
File Delete
. file contains
< >
LogFile1
File Transfer..
00100/01230
Total data
Transferred data
<▲> or <▼> to select items, press < > to have a select order, press
< > for more than 3 seconds to return.
【
File Select】The selected file is the current log file
【
File Transmit】Transmit the selected log file to the USB port, it can be received by ―LogView‖(See details in P17)
【
File Empty】Empty all selected log files. Press< >, the screen shows ‖Are you sure you want to empty?‖, and press < > to confirm, and any other press to cancel.
【
File Delete】Delete the selected file. Press< >, the screen shows
―Are you sure you want to empty?‖, and press < > to confirm, and any other press to cancel.
-12-
Cell Voltage Monitor & Logger CellLog 8S
System Settings: Select【System…】, press < >, the screen shows:
SYSTEM SETTING
Beep Tone
LCD Screen
ALM Output
<▲> or <▼> to select items, press < > to have a select item, press
< > for more than 3 seconds to return.
See details below.
1) Beep Tone Settings: Select【Beep Tone】, press < >, the screen shows:
<▲> or <▼> to select the items, and press < > to shift select /,
BEEP TONE
Key Tone
Hint Tone
Alarm Tone press < > for 3 seconds to confirm the amendment and then return.
Select【Key Tone】,the buttons tone open.
Select【Hint Tone】,the status tone open.
Select【Alarm Tone】,the alarm tone open. (have a ―Do‖ every 4 seconds)
2) LCD Brightness & Contrast Setting : Select【LCD Screen】, press < >, the screen shows:
Brightness
<▲> increase, <▼> decrease, and press < > to shift
-
■■■■■■
+
Contrast
-
■■■■■■
+
Brightness/Contrast, press < > for 3 seconds to confirm the amendment and then return.
3) Alarm Output Signal Type Setting:【ALARM Output】
【
NO.】: Always On. Two output of ALM, it‘s open when there is no
ALARM OUTPUT
⊙NO.
○NC. alarm; It‘ short circuit with alarm.
【
NC.】: Always Close. Two output of ALM, it‘s short circuit when there is no alarm; It‘s open with alarm.
4) Record Interval Time Setting:【Rec. Interval】
RECORD INTERVAL
(0.5-60Seconds)
2
Interval Time
<▲> or <▼> to increase/decrease, press < > to confirm amendment and return. Press< > for 3 seconds to cancel amendment and return.
Setting range:0.5-60 Seconds
5) Start-up Setting:【Start…】
START SETTING
Start Music
Logo Screen
Inf.Screen
<▲> or <▼> to select the items, and press < > to shift select /, press < > for 3 seconds to confirm the amendment and then return.
Select【Start Music】, there will be a start music if you turn on
Select【Logo Screen】, it will display Logo Screen if you turn on
Select【Inf. Screen】, it will display Information Screen if you turn on
-13-
Cell Voltage Monitor & Logger CellLog 8S
6) Power Management: 【Power management】
POWER MANAGEMENT
⊙Not Save
○Backlight OFF
○Sleep Mode
【 Not Save】: it will work as usual
【
Backlight Off】, it will turn off the backlight after minutes not working with any key, the time can be set by the users. Press any key to return
SAVE TIME SET
Minutes(1-240)
005
< > to the normal status. Press < > to enter to SAVE TIME SET.
【
Sleep Mode】, it will turn to Sleep Mode after minutes not working with any key, the time can be set by the users. Press any key to return to the normal status. Press < > to enter to SAVE TIME SET.
<▲> or <▼> to increase/decrease, press < > to confirm amendment and return. Press< > for 3 seconds to cancel amendment and return.
Setting range:1-240 Minutes
Calibration Settings: Select【Calibration】, and press < >, the screen shows:
【
Default】: Calibration Default.
CALIBRATION
⊙Default
○User Setting
【
User Setting】: See details in P15
-14-
Cell Voltage Monitor & Logger CellLog 8S
User Calibration
The CellLog 8S has been calibrated before entering to the markets, but if the users find that there is too much deviation, and then they can calibrate it as the following items:
Before calibration, you need prepare:
8s battery pack (the individual voltage ranges from 3.8-4.2V)
4
1
2 Digital Multimeter
Calibrating steps:
1. Connect pack balance port to CellLog 8S to confirm there are 8 cell voltage display.
2. Press <MENU> for 3 seconds to enter Main Menu--【Calibration】-> CALIBRATION--【User Setting】,then it shows:
1 4.012V 2 4.032V
3 4.018V 4 4.015V
5 4.022V 6 4.017V
7 4.002V 8 4.019V
,
3. The current need-to-be calibrated voltage begins to blink(shows the voltage and calibrated value alternatively), and use multimeter to measure the individual voltage corresponding to the blinking voltage. If the displayed value is more than the measured value, please press <▼> to decrease the displayed value to the measured value; vice versa, please press <▲> to increase the displayed value to the measured value.
Press < > and shift to the next voltage calibration. In this way to get 8 sets voltage calibration.
4. Press <▲> and <▼> for 3 seconds to save the amendment and exit; Press < > for 3 seconds, it will cancel the amendment and exit.
5. The above is only for 8S individual cell measurement calibration, the methods are same for CellLog 8S measure port 1, 2 to measure pack voltage calibration.
Connect 1, 2 to the battery pack‘s negative and positive pole respectively, then follow the Step 2, 3, 4.
1 32.12V 2 ------
3 ------ 4 ------
5 ------ 6 ------
7 ------ 8 ------
Note:
If the user calibrates it in a wrong way, which damage the battery or cause other serious danger, our company will be of no responsibility.
The users’ calibrated value will not affect the calibrated before entering to the market. It can be selected by
CALIBRATION--【User Setting】or【Default】.
-15-
Cell Voltage Monitor & Logger CellLog 8S
USB port installation
Install USB driver
This release of the USB driver is contained on the CellLog 8S software CD-ROM.
To install the USB driver, run the program X:\USB driver\JunsiUSBInstaller.exe (where X is the drive letter designator for your CD-ROM drive.)
Charger firmware upgrade steps
Install the CellLog 8S USB driver
Run the program X:\Upgrader\Upgrader.exe (you can download the Upgrader.exe software from the following website: http://www.jun-si.com/UploadFiles/Upgrader.rar ).
Connect the CellLog 8S to the PC using the supplied USB cable, choose ―Device‖ in ―Device List‖, then select the upgrade file (you can download the latest file). The progress bar will appear after you click
―Update…‖
-16-
Cell Voltage Monitor & Logger CellLog 8S
Using LogView for CellLog 8S
First, our sincere gratitude to the LogView development team: http://www.logview.info
Ensure you have installed the USB driver for the CellLog 8S.
Communication steps:
To install LogView, run the program X:\ logview \ LogViewInstaller.exe (where X is the drive letter designator for you CD-ROM drive.)
Connect the CellLog 8S to the PC using the supplied USB cable
Start LogView , then follow the illustrated instructions below:
1) Please choose language first, since the default language is German.
2) Click DeviceChoose device and port.
-17-
Cell Voltage Monitor & Logger CellLog 8S
3) Choose Junsi CellLog 8S from the list and then choose the correct communication Port.
4) Click ―Start recording‖ to record data.
Refer to the LogView online help for more information about its features and operation.
-18-
Cell Voltage Monitor & Logger CellLog 8S
Optional parts
Balance Connector Conversion Board
CB1010-XH CB1010-EH
70
X
44mm
For Align/Dualshy pack etc.
CB1010-AQP
70
X
44mm
For Kokam/Graupher pack etc.
CB1010-TP
Wire
BW-911
68
X
51mm
For Polyquest/Hyperion pack etc.
70
X
44mm
For Thunder power/Flight power packs etc.
100mm
Balance board connector 9-11
-19-
Cell Voltage Monitor & Logger CellLog 8S
Limited warranty
CellLog 8S is guaranteed to be free from defects in material and workmanship for a period of one calendar year from date of purchase. Your selling dealer is your first point of contact for warranty issues.
Return postage costs are the responsibility of the user in all cases. Submit copy of original receipt with the return.
Damage due to physical shock (dropping on the floor, etc), inappropriate power supply (automotive battery charger, etc), water, moisture, and humidity are specifically NOT covered by warranty. If there is damage stemming from these causes within the stated warranty period, the company will, at its option, repair or replace the CellLog for a service charge not greater than 50% of its then current retail list price.
Date of purchase/delivery:
Dealer:
V3.0
Note: The manufacturer requires the user to be notified of any change or modification made to this device.
Enjoy the power!
-20-