Cell Voltage Monitor & Logger CellLog 8S

Thank you for purchasing the CellLog 8S. Please read the entire User‘s Manual completely and attentively as it contains a wide variety of specific programming and safety information.

Specifications

Lithium (LiPo/LiIo/LiFe) battery cell count:

Pack voltage range:

Alarm pack voltage range:

Cell voltage range:

Alarm cell voltage range:

Voltage display resolution:

Current loading of test:

Maximum voltage for alarm port:

2 – 8 series

4.0 – 43.0VDC (USB can provide lower voltage 1.0V)

0.1 – 43.0VDC

1.3 – 4.9VDC

1.3 – 4.9VDC

1mV

8mA

50VDC

Current drain for alarm port: <500mA

Log Files storage: 16Mbit (43 hours@2 seconds logging interval)

Sample logging time interval:

PC Connect:

Weight:

Dimensions (L X W X D):

0.5 –

18g

60 seconds

USB port

62X39X12mm

2.44‖X1.53‖X0.47‖

Special features

 Small size with multiple functions, backlight 128*64 lattices LCD and Buzzer Tone Reminder; the interface can be operated smoothly.

CellLog 8S can not only measure 2-8S Li battery individual voltage, but also measure NiMH, NiCd, Pb battery pack voltage.

 It can be set Individual Voltage Alarm and Pack Voltage Alarm, Overvoltage Alarm, Low Voltage Alarm,

Differential Voltage Alarm and Time Over Alarm. What‘s more, the extra alarm output can be linkage controlled by the users.

 It has 8 sets default monitor alarm settings, which can be selected for different battery packs.

CellLog 8S has been 100% calibrated before it enters to the market, at the same time, it supports the calibration by users themselves.

The logging interval can be set by users‘ different needs. CellLog 8S has a 16Mbit flash storage, which can log offline data in 43 hours @2 seconds logging interval.

 Support upgrading the hardware program by USB port. The CellLog 8S also supports the ―logview‖ software and can display, plot and analyze the charge and discharge data by it. (See detail information about logview in the following website: http://www.logview.info

)

-2-

Cell Voltage Monitor & Logger CellLog 8S

Unpack inspection

The following items are included in the package. Contact your supplier if any items are missing.

Standard items:

CDROM

CW-USB5

85

X

85mm

One copy of the User’s manual on CDROM

CW-P220

80mm

CW-C220

One Mini-USB data line

20mm

One Alarm output line

Optional items:

See details in ―Optional parts‖ (P19)

20mm

One pack voltage measurements line with clips

-3-

Cell Voltage Monitor & Logger CellLog 8S

External controls and connections

1. Input plug 2. LCD screen 3. Function button 4. USB port 5. Beep 6. Alarm port

CellLog 8S Connection Diagram

+

8

7

6

5

4

3

2

-

TYPE

HOLD

MENU

8S

7S

+

-

+

-

6S

+

5S

4S

-

+

-

+

-

3S

2S

1S

+

-

+

-

+

-

PIN 9

5

4

3

2

8

7

6

1

PIN 1

5S

4S

3S

+

-

+

-

+

-

2S

1S

+

-

+

-

PIN 9

5

4

3

2

1

8

7

6

PIN 1

BATT.

PACK

(4—43V)

+

PIN 9

5

4

3

2

1

8

7

6

PIN 1

-4-

Cell Voltage Monitor & Logger CellLog 8S

Program flow chart

CellLog

POWER ON

Logo Screen

S/N:XXXXXXXXXX

CellLog 8S

Ver X.X.X www.hillrc.com

Inf. Screen

TYPE XXXXXXXXXX

LOGS 0 RATE 2.0

[2016Kb/043h:57]

Logs OFF

Data Log

 Time is shown in the upper right corner blinkingly

 Transfer data to USB port

 Save data to the appointed

Log File

<HOLD>

>3 Seconds

<HOLD>

>3 Seconds

<▢>

<>

Note: When you turn off the CellLog 8S it will remember the current screen and start from that screen when next turned on again.

12345677S 28.79

6H 4.162

1L 4.013

V 149mV

<MENU>

<▢>

<>

>3 Seconds

1 4.013V 2 4.150V

3 4.110V 4 4.152V

5 4.087V 6 4.162V

7 4.120V 8 ------

<TYPE>

>3 Seconds

Main Menu

Voltage Monitor

MAIN MENU

Log Files

System...

Calibration

LOG FILE

⊙Logs OFF

○LogFile1

SYSTEM SETTING

Beep Tone

LCD Screen

ALM Output

POWER MANAGEMENT

⊙Not Save

○Backlight OFF

○Sleep Mode

Rec. Interval

Start...

Power Management

Calibration Select

CALIBRATION

⊙Default

○User Setting

<▢>

<>

7S 28.79V

V 149mV

1 4.01

2 4.15

3 4.11

4 4.15

5 4.08

6 4.16

7 4.12

8 ----

<MENU>

>3 Seconds

Select Type

Details in Page 6

Log File Operation

LogFile1

File Select

File Empty

File Delete

.

Start Setting

File Transmit

START SETTING

Start music

Logo Screen

Inf.Screen

User Calibration

1 ------ 2 ------

3 ------ 4 ------

5 ------ 6 ------

7 ------ 8 ------

7S 28.79V

HV 28.80V

LV 28.78V

P 0.020V

<>+<▼>

Search Results

Details in Page 6

Tone Setting

BEEP TONE

<MENU>

Key Tone

Hint Tone

Alarm Tone

-

■■■■■■

+

Contrast

-

■■■■■■

+

○NC.

>3 Seconds

LCD Brightness& Contrast

Brightness

ALM Output Setting

ALARM OUTPUT

⊙NO.

Record Interval

RECORD INTERVAL

(0.5-60Seconds)

2

Note

means if no operation on the button for 1 minutes, the system will return to monitor screen automatically.

-5-

Cell Voltage Monitor & Logger CellLog 8S

SELECT TYPE

⊙LiPo

○Lilo

○LiFe

Select Type

LiPo

Select

Rename

Alarm

ALARM SETTING

Cells Voltag

Pack Voltage

Safety Timer

Alarm Trigger

CELLS ALARM VOLT

HV 4.22V

LV 3.00V

V 500mV

Pack Alarm Voltage Setting

PACK ALARM VOLT

HV 43.00V

LV 1.000V

P 42.00V

SAFETY TIMER

Minutes(1-999)

120

Alarm Trigger Select

ALARM TRIGGER

Over Voltag

Low Voltage

Difference

Time Over

<MENU>

>3 Seconds

<>+<▼>

<TYPE>

>3 Seconds

Voltage Monitor

<MENU>

>3 Seconds

00m:00

12345677S 28.79

6H 4.162

1L 4.013

V 149mV

<▢>

<>

Note

means if no operation on the button for 1 minutes, the system will return to monitor screen automatically.

Search Results

00m:00

Star t Location

1 4.013V 2 4.150V

3 4.110V 4 4.152V

5 4.087V 6 4.162V

7 4.120V 8 ------

<▢>

<>

7S 28.79V

V

00m:00

149mV

1 4.01

2 4.15

3 4.11

4 4.15

5 4.08

6 4.16

7 4.12

8 ----

<▢>

<>

7S 28.79V 00m:00

HV 28.80V

LV 28.78V

P 0.020V

Note: The upper right corner of the screen will alternatively blink time 00m: 00

<MENU>

50m:20 50m:20

Ending Location

50m:20

12345677S 21.79

6H 3.162

1L 3.013

V 149mV

<▢>

<>

1 3.013V 2 3.150V

3 3.110V 4 3.152V

5 3.087V 6 3.162V

7 3.120V 8 ------

<▢>

<>

7S 21.79V

V 149mV

1 3.01

2 3.15

3 3.11

4 3.15

5 3.08

6 3.16

7 3.12

8 ----

<▢>

<>

7S 21.79V 50m:20

HV 21.80V

LV 21.78V

P 0.020V

Note: The upper right corner of the screen will alternatively blink ending time xxx:xx

48m:10

<MENU>

1 Low 2 ------

3 ------ 4 ------

5 ------ 6 ------

7 ------ 8 ------

Alarm time points

If there is alarm, the alarm events/alarm

time will be shown alternatively at the corresponding battery number place.

-6-

Cell Voltage Monitor & Logger CellLog 8S

Menu Operation:

1. Select the menu items by <▲> /<▼> buttons, the selected item will be shown in white.

2. Press < > to the following menu, and hold < >for more than 3 seconds, it will return to the upper menu.

Symbol Meanings:

Display Symbols The meaning of the Symbols Note

nS nH total voltage of the pack the highest individual cell voltage n:0-8, the cell count n:0-8, the highest cell number nL the lowest individual cell voltage n:0-8, the lowest cell number

▣V

HV the maximum voltage difference between the cells

▣V

= nH

- nL

The voltage maximum value

LV

▣P the voltage minimum value the pack maximum voltage difference mmM:ss

or

hhH:mm the time entering to logging

▣P = HV - LV ss:second ,mm:minute , hh: hour

⊙/○

Single choice Do/Do not

/□

Multiple choice Do/Do not

T_OVER

Safety time alarm

LOW

OVER

Low voltage alarm

Over voltage alarm

DIFF

Voltage difference alarm

Button Function

CellLog has 3 buttons, which everyone owns the first and second functions. The first function is trigger after only one click; the second function is trigger after 3 seconds holding of the button.

Press button Condition Button Function Description

<▲>

Click 1. Turns up the menu

2. Increase the value

3. Select the character input

<▼>

< >

Hold for 3 seconds

Click

Hold for 3 seconds

Click

Enter to Alarm type select menu

1. Turns down the menu

2. Decrease the value

3. Delete the character

Trigger Open/Close Logging Function

Confirmation

<▲>+<▼>

Hold for 3 seconds

Click

Enter to System Setting Menu

Check logging information

Hold for 3 seconds Save users voltage calibrated value

Note<▲>+<▼> means pressing <▲> and <▼> at the same time.

-7-

Cell Voltage Monitor & Logger CellLog 8S

QUICK START

CellLog Power On Rec. Interval

(2 ways: one is connecting the battery through the left 9 Pin socket, the other one is through the USB port),

System self-check, and then shows the SN and version number, the display information are as below:

TYPE XXXXXXXXXX

Alarm configuration Name

Existent Log Files Number

The first line is the current selected Setting Type (See

LOGS 0 RATE :2.0

[2016Kb/35h:50]

Logs OFF

Record interval time

Free Capacity/Free Time

Current Log File Name detail in P10). The second line shows the log file number.

And the third line is the available record of capacity and time. The last line shows the current log file name (if no files, it shows "Logs OFF"). 3 seconds later, the system enters to voltage monitor status.

Voltage Monitor

There are 4 interface choices, which can be shifted by <▲> or <▼>buttons.

Pack Voltage

As the left pictures: the ‘7‘ in ‖7S‖ means cell counts; ‘6H‘ means the 6 th

cell voltage is the highest; ‘1L‘ means the 1 st

Cell Number

Voltage

Histogram

12345677S 28.79

<▢>

6H 4.162

1L 4.013

V 149mV

<>

Cell Number

1 4.013V 2 4.150V

3 4.110V 4 4.152V

5 4.087V 6 4.162V

7 4.120V 8 ------

The highest voltage

The lowest voltage

The maximum voltage difference

Cell Voltage cell voltage is the lowest.

If the monitor voltage trigger alarm, the corresponding voltage and alarm display (LOW, OVER or DIFF) shows alternatively.

The cell number and (L, O, D) shows alternatively.

LOW‘ or ‗L‘ means: Low voltage alarm

Pack Voltage

Cell Number

<▢>

<>

7S 28.79V

V 149mV

1 4.01

2 4.15

3 4.11

4 4.15

5 4.08

6 4.16

7 4.12

8 ----

The Max. Voltage difference

Cell Voltage

OVER‘ or ‗O‘ means: Over voltage alarm

DIFF‘ or ‗D‘ means: Voltage difference alarm. They will be cell voltage interface. displayed at the same time at the highest and the lowest

<▢>

<>

7S 28.79V

HV 28.80V

LV 28.78V

P 0.020V

Pack Voltage

Max. Pack Voltage

Min. Pack Voltage

Pack Voltage Difference

Monitor the pack voltage

Display respectively: Current pack voltage, Max. Pack voltage, Min. Pack voltage, Pack voltage difference. (▣P =

HV-LV

)

Data Logging

When in Voltage Monitor status, press <▼> button for 3 seconds, after it shows ‖Start logging…‖, the calculagraph will be shown alternatively at the upper right corner of the LCD screen. In this status, the system will transmit the voltage data to USB port every X seconds( this interval time X can be set by user himself, details you can see Record Interal Time Setting in P13), and save these data to the current Log file(See

Log File Management in P12. If 【Logs OFF】, the system will not log file)

Press <▼> for 3 seconds again, the screen will show ‖Stop logging!‖ and then exit.

View Logging Point

In the monitor status, press <▲> and <▼> at the same time to enter the view logging point status.

Three points voltage data can be searched:‖Starting logging…‖data, ‖Stop logging!‖ data, and the data of voltage alarm during this period , which can be shifted by < > buttons. Press < > for 3 seconds,it will return to the monitor status.

The saved data can be covered till next logging.

If the logging time is over the users setting safety time,(See Monitor Safety Time Setting in P11), it will trigger Safety Time Alarm, and the screen shows ‖T_OVER‖ alternatively in the upper right corner.

-8-

Cell Voltage Monitor & Logger CellLog 8S

Alarm Remind

If CellLog detect the alarm events (See Alarm Trigger Settings in P11), it will remind as below:

1. The buzzer beeps every 4 seconds(【Alarm Tone】is selected , See P13).

2. The corresponding individual voltage and alarm remind show alternatively.

Alarm Remind Information: ―LOW‖, ―OVER‖, ―DIFF‖, ―T_OVER‖

3. ALM port will output the presetting signal.

ALM port signal information:

ALM output port signal is open collector signal, as showed below.

ALM Output

Q9

Please pay attention to the port voltage and current limit when you use(<50V,<500mA)

The following are ALM Output typical application.

VCC VCC

Output

R

ALM

Output

Level Output Relay Output

ALM

-9-

Cell Voltage Monitor & Logger CellLog 8S

Monitor Alarm Settings

The system can have 8 sets alarm settings, press <▲> for 3 seconds to enter SELECT TYPE menu.

SELECT TYPE

⊙LiPo

○Lilo

○LiFe

LiPo

< >

Select

Rename

Alarm

The item with  is the current setting.

<▲> or <▼> to select items and press < > button.

Defaulted TYPEs are: LiPo, Lilo, LiFe, User1--5

Operate the selected type settings

<▲> or <▼> to select the items, press < > to enter to the next step.

See details below.

Note: Press<▲> button to power on, it will shift to LiPo Type automatically.

Press <▼> button to power on, it will shift to Lilo Type automatically.

Press < > button to power on, it will shift to LiFe Type automatically.

Change Current Alarm Type: Select【Select】, Press < > then the item will be with , and the settings come into effect.

Rename Alarm Type: Select【Rename】, press < > and the screen shows:

LiPo

Rename

New Name

LiPo-1200mAh

New Name Input Method: <▲> to select characters, hold it to trigger continuously; <▼> to delete the current character; < > to confirm the selected character; press < > for 2 times to confirm the amendment and return; press < > for 3 seconds to cancel and return.

Alarm Parameters Setting: Select【Alarm】, press < > and the screen shows:

ALARM SETTING

Cells Voltag

Pack Voltage

Safety Timer

Alarm Trigger

<▲> or <▼> to select items, press < > enter to the next step

See details below.

1) Individual Cell Voltage Alarm Settings: Select【Cells Voltage】, press < > and the screen shows:

CELLS ALARM VOLT

HV 4.22V

LV 3.00V

V 500mV

Cell Alarm Upper Limit

Cell Alarm Lower Limit

Cell Alarm Difference

<▲> or <▼> to increase/decrease voltage value, press < > to shift setting items. Press < > for 3 seconds to confirm amendment and return.

HV

: 1.31V—4.90V LV: 1.30V—4.89V ▣V: 0.01—3.60V

2) Pack Alarm Voltage Setting: Select【Pack Voltage】, press < > and the screen shows:

PACK ALARM VOLT

<▲> or <▼> to increase/decrease voltage value, press < > to shift

HV 43.00V

LV 1.000V

P 42.00V

Pack Alarm Upper Limit

Pack Alarm Lower Limit

Pack Alarm Difference setting items. Press < > for 3 seconds to confirm amendment and return.

HV

: 1.05V—43.00V LV: 1.00V—42.95V ▣P: 0.05—42.00V

-10-

Cell Voltage Monitor & Logger CellLog 8S

3) Monitor Safety Time Setting: Select【Safety Timer】, press < > and the screen shows:

SAFETY TIMER

Minutes(1-999)

120

Safety Time

<▲> or <▼> to increase/decrease, press < > to confirm amendment and return. Press< > for 3 seconds to cancel amendment and return.

Setting range: 1-999 minutes

4) Alarm Trigger Settings: Select【Alarm Trigger】, press < > and the screen shows:

<▲> or <▼> to select items, press < > to shift select /,

ALARM TRIGGER

Over Voltag

Low Voltage

Difference

Time Over press< > for 3 seconds to confirm amendment and return.

Select【Over Voltage】Cell or pack voltage are over HV setting value, then it alarms.

Select【Low Voltage】Cell or pack voltage are lower LV setting value, then it alarms.

Select【Difference】Cell voltage is over ▣V or the pack voltage difference is over ▣P setting value, then it alarms.

Select【Time Over】 entering HOLD status time is over setting safety time ,then it alarms.

-11-

Cell Voltage Monitor & Logger CellLog 8S

Parameter Setup

Press < > for 3 seconds, and enter to the MAIN MENU, Monitor status.

MAIN MENU

Log Files

System...

Calibration

Log File Management: Select【Log Files】, press < > and the screen shows:

LOG FILE

⊙Logs OFF

○LogFile1

The first item is【Logs OFF】,if it is chosen, LOG function is close.

Press <▲> for 3 seconds to create new Log files.

< >

>3 Sec

FILE CREATE

File Name:

LogFile1

The operation to the existing files:

Log file name input method:

<▲> to select characters, hold it to trigger continuously; <▼> to delete the current character; < > to confirm the selected character; press < > for 2 times to confirm the amendment and return; press< > for 3 seconds to cancel and return.

LOG FILE [01230]

Logging number the

⊙Logs OFF

○LogFile1

LogFile1

< >

File Select

File Transmit

File Empty

File Delete

. file contains

< >

LogFile1

File Transfer..

00100/01230

Total data

Transferred data

<▲> or <▼> to select items, press < > to have a select order, press

< > for more than 3 seconds to return.

File Select】The selected file is the current log file

File Transmit】Transmit the selected log file to the USB port, it can be received by ―LogView‖(See details in P17)

File Empty】Empty all selected log files. Press< >, the screen shows ‖Are you sure you want to empty?‖, and press < > to confirm, and any other press to cancel.

File Delete】Delete the selected file. Press< >, the screen shows

―Are you sure you want to empty?‖, and press < > to confirm, and any other press to cancel.

-12-

Cell Voltage Monitor & Logger CellLog 8S

System Settings: Select【System…】, press < >, the screen shows:

SYSTEM SETTING

Beep Tone

LCD Screen

ALM Output

<▲> or <▼> to select items, press < > to have a select item, press

< > for more than 3 seconds to return.

See details below.

1) Beep Tone Settings: Select【Beep Tone】, press < >, the screen shows:

<▲> or <▼> to select the items, and press < > to shift select /,

BEEP TONE

Key Tone

Hint Tone

Alarm Tone press < > for 3 seconds to confirm the amendment and then return.

Select【Key Tone】,the buttons tone open.

Select【Hint Tone】,the status tone open.

Select【Alarm Tone】,the alarm tone open. (have a ―Do‖ every 4 seconds)

2) LCD Brightness & Contrast Setting : Select【LCD Screen】, press < >, the screen shows:

Brightness

<▲> increase, <▼> decrease, and press < > to shift

-

■■■■■■

+

Contrast

-

■■■■■■

+

Brightness/Contrast, press < > for 3 seconds to confirm the amendment and then return.

3) Alarm Output Signal Type Setting:【ALARM Output】

NO.】: Always On. Two output of ALM, it‘s open when there is no

ALARM OUTPUT

⊙NO.

○NC. alarm; It‘ short circuit with alarm.

NC.】: Always Close. Two output of ALM, it‘s short circuit when there is no alarm; It‘s open with alarm.

4) Record Interval Time Setting:【Rec. Interval】

RECORD INTERVAL

(0.5-60Seconds)

2

Interval Time

<▲> or <▼> to increase/decrease, press < > to confirm amendment and return. Press< > for 3 seconds to cancel amendment and return.

Setting range:0.5-60 Seconds

5) Start-up Setting:【Start…】

START SETTING

Start Music

Logo Screen

Inf.Screen

<▲> or <▼> to select the items, and press < > to shift select /, press < > for 3 seconds to confirm the amendment and then return.

Select【Start Music】, there will be a start music if you turn on

Select【Logo Screen】, it will display Logo Screen if you turn on

Select【Inf. Screen】, it will display Information Screen if you turn on

-13-

Cell Voltage Monitor & Logger CellLog 8S

6) Power Management: 【Power management】

POWER MANAGEMENT

⊙Not Save

○Backlight OFF

○Sleep Mode

【 Not Save】: it will work as usual

Backlight Off】, it will turn off the backlight after minutes not working with any key, the time can be set by the users. Press any key to return

SAVE TIME SET

Minutes(1-240)

005

< > to the normal status. Press < > to enter to SAVE TIME SET.

Sleep Mode】, it will turn to Sleep Mode after minutes not working with any key, the time can be set by the users. Press any key to return to the normal status. Press < > to enter to SAVE TIME SET.

<▲> or <▼> to increase/decrease, press < > to confirm amendment and return. Press< > for 3 seconds to cancel amendment and return.

Setting range:1-240 Minutes

Calibration Settings: Select【Calibration】, and press < >, the screen shows:

Default】: Calibration Default.

CALIBRATION

⊙Default

○User Setting

User Setting】: See details in P15

-14-

Cell Voltage Monitor & Logger CellLog 8S

User Calibration

The CellLog 8S has been calibrated before entering to the markets, but if the users find that there is too much deviation, and then they can calibrate it as the following items:

Before calibration, you need prepare:

 8s battery pack (the individual voltage ranges from 3.8-4.2V)

 4

1

2 Digital Multimeter

Calibrating steps:

1. Connect pack balance port to CellLog 8S to confirm there are 8 cell voltage display.

2. Press <MENU> for 3 seconds to enter Main Menu--【Calibration】-> CALIBRATION--【User Setting】,then it shows:

1 4.012V 2 4.032V

3 4.018V 4 4.015V

5 4.022V 6 4.017V

7 4.002V 8 4.019V

,

3. The current need-to-be calibrated voltage begins to blink(shows the voltage and calibrated value alternatively), and use multimeter to measure the individual voltage corresponding to the blinking voltage. If the displayed value is more than the measured value, please press <▼> to decrease the displayed value to the measured value; vice versa, please press <▲> to increase the displayed value to the measured value.

Press < > and shift to the next voltage calibration. In this way to get 8 sets voltage calibration.

4. Press <▲> and <▼> for 3 seconds to save the amendment and exit; Press < > for 3 seconds, it will cancel the amendment and exit.

5. The above is only for 8S individual cell measurement calibration, the methods are same for CellLog 8S measure port 1, 2 to measure pack voltage calibration.

Connect 1, 2 to the battery pack‘s negative and positive pole respectively, then follow the Step 2, 3, 4.

1 32.12V 2 ------

3 ------ 4 ------

5 ------ 6 ------

7 ------ 8 ------

Note:

If the user calibrates it in a wrong way, which damage the battery or cause other serious danger, our company will be of no responsibility.

The users’ calibrated value will not affect the calibrated before entering to the market. It can be selected by

CALIBRATION--User SettingorDefault.

-15-

Cell Voltage Monitor & Logger CellLog 8S

USB port installation

Install USB driver

This release of the USB driver is contained on the CellLog 8S software CD-ROM.

To install the USB driver, run the program X:\USB driver\JunsiUSBInstaller.exe (where X is the drive letter designator for your CD-ROM drive.)

Charger firmware upgrade steps

 Install the CellLog 8S USB driver

 Run the program X:\Upgrader\Upgrader.exe (you can download the Upgrader.exe software from the following website: http://www.jun-si.com/UploadFiles/Upgrader.rar ).

 Connect the CellLog 8S to the PC using the supplied USB cable, choose ―Device‖ in ―Device List‖, then select the upgrade file (you can download the latest file). The progress bar will appear after you click

―Update…‖

-16-

Cell Voltage Monitor & Logger CellLog 8S

Using LogView for CellLog 8S

First, our sincere gratitude to the LogView development team: http://www.logview.info

Ensure you have installed the USB driver for the CellLog 8S.

Communication steps:

 To install LogView, run the program X:\ logview \ LogViewInstaller.exe (where X is the drive letter designator for you CD-ROM drive.)

 Connect the CellLog 8S to the PC using the supplied USB cable

 Start LogView , then follow the illustrated instructions below:

1) Please choose language first, since the default language is German.

2) Click DeviceChoose device and port.

-17-

Cell Voltage Monitor & Logger CellLog 8S

3) Choose Junsi CellLog 8S from the list and then choose the correct communication Port.

4) Click ―Start recording‖ to record data.

Refer to the LogView online help for more information about its features and operation.

-18-

Cell Voltage Monitor & Logger CellLog 8S

Optional parts

Balance Connector Conversion Board

CB1010-XH CB1010-EH

70

X

44mm

For Align/Dualshy pack etc.

CB1010-AQP

70

X

44mm

For Kokam/Graupher pack etc.

CB1010-TP

Wire

BW-911

68

X

51mm

For Polyquest/Hyperion pack etc.

70

X

44mm

For Thunder power/Flight power packs etc.

100mm

Balance board connector 911

-19-

Cell Voltage Monitor & Logger CellLog 8S

Limited warranty

CellLog 8S is guaranteed to be free from defects in material and workmanship for a period of one calendar year from date of purchase. Your selling dealer is your first point of contact for warranty issues.

Return postage costs are the responsibility of the user in all cases. Submit copy of original receipt with the return.

 Damage due to physical shock (dropping on the floor, etc), inappropriate power supply (automotive battery charger, etc), water, moisture, and humidity are specifically NOT covered by warranty. If there is damage stemming from these causes within the stated warranty period, the company will, at its option, repair or replace the CellLog for a service charge not greater than 50% of its then current retail list price.

Date of purchase/delivery:

Dealer:

V3.0

Note: The manufacturer requires the user to be notified of any change or modification made to this device.

Enjoy the power!