Y
NOTE: Use RH Vertical Only
Co/Struc
®
Keyless Locking Doors Vertical
OVERVIEW
The KitLock has a 10 button keypad and a # button.
The # button is hidden beneath the handle when in the locked position.
●
Blue LED = Code accepted
Red LED = Code rejected
BASICS
• The KitLock has four code levels available: i) Master Code ii) Sub‐Master Code iii) User Code iv) Technician Code
• The KitLock is supplied with two factory set codes:
Master Code: 11 33 55 77
User Code: 22 44
• When fitted, immediately change the Master Code and User Code.
• All Master Codes and Sub‐Master Codes are 8 digits long.
• All User Codes are 4 digits long.
• All Technician Codes are 6 digits long.
• The lock ‘open’ time is set at 4 seconds.
FUNCTIONS
Before programming select the most appropriate function for the application:
A) or B) ‐ See special Master Code set up commands.
A) REPEATED USE
Important Note: This is the default function and is already pre‐programmed in new locks.
This is the most common function and is used where the same code will be repeatedly used.
B) SINGLE USE (Locker Mode)
The user enters their own personal four‐digit code twice, the second time to confirm the correct code.
This locks the lock. The same code is entered once only to open the lock before being erased and ready for the next new user.
This function is used for short term, multioccupancy applications, e.g. a locker in a fitness center.
PENALTY TIME
• Entering three incorrect codes will cause the lock to shutdown for 10 seconds.
BATTERY POWER
• The lock should provide well in excess of 15,000 openings, of 4 seconds each, from 2 AAA 1.5v cells.
LOW BATTERY
• When the battery power is low the Red LED will flash 3 times before the Blue LED flashes to signal acceptance of the code. Batteries should be changed as soon as this happens. The lock will operate for 100 openings with low battery.
CODES
• The code can open the lock and change the code.
• The lock is supplied with the factory default code
22 44.
• To insure the maximum security, immediately change the code. The code must be 4 digits long.
• To open, enter a code and turn the latch. To secure, return the latch to its original position.
BATTERY FAILURE OVERRIDE
The lock has been designed so an external 9V battery can be placed against the contact points surrounding the Blue and Red LEDs so the lock can be opened to replace the batteries should they fail.
The procedure is as follows:
• Place the contact points of the 9V battery against the contact points surrounding the Blue and Red
LEDs.
• Place the positive terminal of the 9V against the Red
LED contact point and the negative terminal of the battery against the Blue LED.
• Enter 11 33 55 77 .
• The motor will withdraw the locking pin allowing the lock to be opened.
• Fit new batteries by removing the upper fixing bolt and swinging the lock down over the edge of the door. Refit the lock.
PROGRAMMING AND CODE FUNCTIONS
PROGRAMMING
To program – the lock must be in the open position with the # button visible. Every program command must commence by pressing the # button, followed by either the Master Code, Sub‐Master Code or User
Code.
MASTER CODE
The Master Code can:
• Open the lock
• Change the Master Code
• Set / Change / Delete the Sub‐Master and User Code
• Select between Private and Public Functions
• Activate/deactivate Technician Code
SUB‐MASTER CODE
The Sub‐Master Code can:
• Open the lock
• Change the Sub‐Master
• Set / Change / Delete / the User Code
Z
© 2014 Herman Miller, Inc. Zeeland, Michigan. Printed in the U.S.A.
® Y , Z , Action Office, Co/Struc and Mirra are among the registered trademarks of Herman Miller, Inc.
TM Sense, Setu, Tu and Compass are among the trademarks of Herman Miller, Inc.
Illustrations and specifications are based on the latest product information available at the time of publication.
The right is reserved to make changes in design and specifications at any time, without notice, and also to discontinue products.
Part no. 1b5t8r rev C.
1
PROGRAMMING AND CODE FUNCTIONS Continued …
USER CODE
The User Code can:
• Open the lock
• Change the User Code
TECHNICIAN CODE
The Technician Code can:
• Open the lock
A code cannot be programmed into more than one level.
LOST CODE PROCEDURE
Note: The procedure requires the door to be open.
• Remove the rear‐fixing bolt and swing the lock over the edge of the door to reveal the battery compartment.
• Remove one battery.
• Press and hold the 1 button, replace the battery, the Blue LED will flash twice, release the 1 button.
Within three seconds, press the 1 button three times. The Blue LED will flash twice and the lock will have reverted to the factory Master Code 11 33 55
77 and all other stored settings will be erased.
CODE COMMANDS
MASTER CODE COMMANDS SUB‐MASTER CODE COMMANDS
CHANGE THE MASTER CODE
#Master Code • 01 • New Master Code •
New Master Code • •
Example: #11335577 • 01 • 12345678 •
12345678 ••
Result: Master Code has been changed to 12345678.
CHANGE THE SUB‐MASTER CODE
#Sub‐Master Code • 06 • New Sub‐
Master Code •
New Sub‐Master Code ••
Example: #87654321 • 06 • 10101010 • 10101010 ••
Result: Sub‐Master Code has been changed to
10101010.
SET OR CHANGE THE USER CODE
#Master Code • 02 • User Code ••
Example: #11335577 • 02 • 9999 ••
Result: New User Code 9999 now operative.
SET OR CHANGE THE USER CODE
#Sub‐Master Code • 07
Example: #87654321 •
•
07
User Code
• 6666 ••
••
Result: New User Code 6666 now operative.
DELETE USER CODE
#Master Code • 03 ••
Example: #11335577 • 03 ••
Result: User Code deleted.
DELETE USER CODE
#Sub‐Master Code • 08
Example: #87654321 •
••
08
Result: User Code deleted.
••
SET OR CHANGE THE SUBMASTER CODE
#Master Code • 04 • Sub‐Master Code •
Sub‐Master Code ••
Example: #11335577 • 04 • 87654321 •
87654321 ••
Result: Sub‐Master Code 87654321 now operative.
USER CODE COMMANDS
CHANGE THE USER CODE
#User Code • New User Code
Example: #2244 • 6688 • 6688
Result: User Code now 6688.
• New User Code
••
••
DELETE THE SUB‐MASTER CODE
#Master Code • 05 • 05 ••
Example: #11335577 • 05 • 05 ••
Result: Sub‐Master Code deleted.
SPECIAL CODE COMMANDS
SET A) REPEATED USE
#Master Code • 26 ••
Example: #11335577 • 26 ••
Result: The lock will revert back to default A) Private
Use Function. Factory set User Code 2244 will now work repeatedly until reprogrammed.
SET B) SINGLE USE (Locker Mode)
#Master Code • 24 ••
Example: #11335577 • 24 ••
Result: The lock will now remain open until the next user enters their own personal code into the lock as follows:
Step 1 – Enter 4 digit code • Confirm 4 digit code ••
Close the locker which will now be locked.
Step 2 – Enter the same 4 digit code •• the lock will now open and remain open until next 4 digit code is entered.
Note: When locked in this mode • LED will flash every 5 seconds to indicate the locker is locked.
SET TECHNICIAN CODE
#Master Code • 99 • Technician Code • Technician
Code ••
Example: #11335577 • 99 • 555555 • 555555 ••
Result: The lock is automatically set into B) Public
Use Function and allows the programmed Techni‐ cian Code to open the lock WITHOUT the entered single use code being erased.
Note: If lock is opened with a Master Code the User
Code will be erased.
Z
© 2014 Herman Miller, Inc. Zeeland, Michigan. Printed in the U.S.A.
® Y , Z , Action Office, Co/Struc and Mirra are among the registered trademarks of Herman Miller, Inc.
TM Sense, Setu, Tu and Compass are among the trademarks of Herman Miller, Inc.
Illustrations and specifications are based on the latest product information available at the time of publication.
The right is reserved to make changes in design and specifications at any time, without notice, and also to discontinue products.
Part no. 1b5t8r rev C.
2
OPERATING INSTRUCTIONS
Note: The lock has a 10‐button keypad and a # button. The # button is hidden beneath the handle when in the locked position.
Lost Code Procedure
Note: The procedure requires the door to be open.
• Remove the rear‐fixing bolt and swing the lock over the edge of the door to reveal the battery compartment.
• Remove one battery.
• Press and hold the 1 button, replace the battery, the blue LED will flash twice, release the 1 button.
•
Within three seconds press the 1 button three
Press “#”, then enter 11 33 55 77 illuminating the blue light
• Press 02, which will result in .
.
. This will result in
• Enter the new code, which will result in
..
EXAMPLE
• Press and hold 1, replace battery,
• Press 1,1,1.
• #113355772
.
02
.
9999
..
..
release 1.
• This will result in the code being set to 9999.
REPLACING THE BATTERIES
Open the door and locate the bolt behind the red and blue lights. Unscrew the bolt and swivel the lock to expose its back. Replace the batteries, return the lock to its position and reinstall the bolt.
CHANGE THE USER CODE
The lock must be in the open position with the # button visible. The change must commence by pressing the # button, followed by the code.
Enter a new code, resulting in
.
.
Enter the new code again, resulting in
.
.
..
EXAMPLE
#2244
.
6688
.
6688
..
This will result in the code being changed to 6688.
Bolt
Latch is in “opened” position
Z
© 2014 Herman Miller, Inc. Zeeland, Michigan. Printed in the U.S.A.
® Y , Z , Action Office, Co/Struc and Mirra are among the registered trademarks of Herman Miller, Inc.
TM Sense, Setu, Tu and Compass are among the trademarks of Herman Miller, Inc.
Illustrations and specifications are based on the latest product information available at the time of publication.
The right is reserved to make changes in design and specifications at any time, without notice, and also to discontinue products.
Part no. 1b5t8r rev C.
3

Public link updated
The public link to your chat has been updated.
Advertisement