Infinite Installation Manual

Add to my manuals
87 Pages

advertisement

Infinite Installation Manual | Manualzz
infinite Installation Manual - Version 3.00
Catalog Number: ZI0249D (9/04)
All data is subject to change without prior notice.
Hereby, Electronics Line 3000 Ltd. declares that this control panel is in compliance with the essential
requirements and other relevant provisions of Directive 1999/5/EC.
-2-
Table of Contents
Chapter One: Introduction ................................................................................................................... 5
1.1: Documentation Conventions .................................................................................................. 5
1.2: Specifications ......................................................................................................................... 6
1.3: System Overview ................................................................................................................... 6
1.4: Hardware Layout .................................................................................................................... 8
Chapter Two: System Installation ...................................................................................................... 12
2.1: Planning the Installation ....................................................................................................... 12
2.2: Opening the Housing ........................................................................................................... 13
2.3: Mounting the Control Panel.................................................................................................. 13
2.4: Back Tamper........................................................................................................................ 14
Chapter Three: Basic System Operation ........................................................................................... 15
3.1: Front Panel Layout ............................................................................................................... 15
3.2: System Status LEDs ............................................................................................................ 15
3.3: Alphanumeric Keypad .......................................................................................................... 16
3.4: LCD Display ......................................................................................................................... 16
3.5: Arming/Disarming................................................................................................................. 17
3.6: Remote Arming/Disarming via SMS..................................................................................... 19
3.7: Front Panel Alarm Activation................................................................................................ 20
Chapter Four: Advanced System Operation...................................................................................... 21
4.1: Menu Navigation .................................................................................................................. 21
4.2: Stop Communications .......................................................................................................... 21
4.3: Sensor Bypassing/Unbypassing .......................................................................................... 22
4.4: User Codes .......................................................................................................................... 22
4.5: Follow Me............................................................................................................................. 24
4.6: Event Log ............................................................................................................................. 24
4.7: Service Menu ....................................................................................................................... 25
Chapter Five: Two-Way Audio........................................................................................................... 29
5.1: Incoming Calls...................................................................................................................... 29
5.2: Outgoing Calls...................................................................................................................... 30
Chapter Six: Home Automation Control............................................................................................. 32
6.1: Keypad Control .................................................................................................................... 32
6.2: Keyfob Control ..................................................................................................................... 32
6.3: SMS Control......................................................................................................................... 32
6.4: Scheduling ........................................................................................................................... 33
Chapter Seven: Devices .................................................................................................................... 34
7.1: Device Registration .............................................................................................................. 34
7.2: Device Descriptors ............................................................................................................... 34
7.3: Device Deletion .................................................................................................................... 35
7.4: Supervision Time ................................................................................................................. 35
7.5: Re-Synchronization.............................................................................................................. 35
7.6: Zones ................................................................................................................................... 36
7.7: Keyfobs ................................................................................................................................ 39
7.8: Keypads ............................................................................................................................... 40
7.9: Repeaters............................................................................................................................. 41
7.10: External Siren..................................................................................................................... 41
7.11: Smartkeys (for future use).................................................................................................. 42
Chapter Eight: Entry/Exit Timers and Arming Tones ......................................................................... 43
8.1: Entry/Exit Delay.................................................................................................................... 43
8.2: Arm on Exit........................................................................................................................... 43
8.3: Arming Tones....................................................................................................................... 43
8.4: System Trouble Tones ......................................................................................................... 45
8.5: Tones Output ....................................................................................................................... 45
-3-
Chapter Nine: System Options .......................................................................................................... 46
9.1: Swinger Setting .................................................................................................................... 46
9.2: Code Lockout ....................................................................................................................... 46
9.3: Forced Arm .......................................................................................................................... 46
9.4: HA Control............................................................................................................................ 46
9.5: Panic Alarm.......................................................................................................................... 47
9.6: One-Key Arming................................................................................................................... 47
9.7: Supplementary Entry Delay.................................................................................................. 47
9.8: Entry Deviation..................................................................................................................... 47
9.9: AC Loss Delay ..................................................................................................................... 48
9.10: Arm Status Display............................................................................................................. 48
9.11: Banner................................................................................................................................ 48
9.12: PGM Output ....................................................................................................................... 49
9.13: Guard Code (for future use) ............................................................................................... 50
9.14: Time/Date Format .............................................................................................................. 50
9.15: “No Arm” Indication ............................................................................................................ 50
9.16: Supervised Arm.................................................................................................................. 51
Chapter Ten: Communications .......................................................................................................... 52
10.1: Accounts ............................................................................................................................ 52
10.2: General Account Options ................................................................................................... 53
10.3: Remote Programming ........................................................................................................ 54
10.4: Service Call ........................................................................................................................ 56
10.5: SMS Center........................................................................................................................ 56
10.6: Communications Options ................................................................................................... 57
10.7: Two-Way Audio Options..................................................................................................... 59
10.8: GSM RX Report ................................................................................................................. 60
10.9: Event Options..................................................................................................................... 60
Chapter Eleven: Home Automation Programming............................................................................. 62
11.1: X10 Overview..................................................................................................................... 62
11.2: HA Units ............................................................................................................................. 62
11.3: House Code ....................................................................................................................... 64
11.4: SMS Confirmation .............................................................................................................. 64
Chapter Twelve: System Initialization................................................................................................ 65
12.1: Initialization ........................................................................................................................ 65
12.2: Default Program Restore ................................................................................................... 65
12.3: Clear User Codes............................................................................................................... 65
12.4: Clear Wireless Transmitters............................................................................................... 65
12.5: Find Modules...................................................................................................................... 66
Appendix A: Menu Structure.............................................................................................................. 67
Appendix B: Transmitter Installation .................................................................................................. 72
PIR Sensors (EL-2600/EL-2600PI/EL-2645/EL-2645PI) ............................................................ 72
Magnetic Contact (EL-2601) ....................................................................................................... 75
Universal Transmitter (EL-2602) ................................................................................................. 76
Glassbreak Sensor (EL-2606)..................................................................................................... 77
Smoke Detector (EL-2603) ......................................................................................................... 80
Keyfobs (EL-2611/EL-2614)........................................................................................................ 80
Wireless Keypads (EL-2620/EL-2640)........................................................................................ 81
Transmitter Specifications........................................................................................................... 83
Appendix C: Event Table ................................................................................................................... 85
-4-
Chapter One: Introduction
This manual is designed to help you install the infinite control panel. We strongly urge
you to read through this manual, in its entirety, before beginning the installation process
so that you can best understand all that this security system has to offer. This manual is
not intended for end user use. End users are encouraged to read the user manual
provided with the system. If you have any questions concerning any of the procedures
described in this manual please contact Electronics Line 3000 Ltd. at (+972-3) 918-1333.
1.1: Documentation Conventions
Throughout the manual, we have tried to include all of the operating and programming
functions using a similar structure and order as they appear in the menu. A detailed
explanation of how to navigate the panel’s menu is included in section 4.1: Menu
Navigation. In order to simplify the procedures that appear in the rest of this manual, the
following conventions are used:
This…
Select…
From the Event Log Menu,
select Clear Log.
From the Service menu, select
Time/Date, Set Date.
[712]
[#5]
4. Speaker Test
,
Means…
Use the arrow keys to scroll through the options and press
.
Enter the main menu by pressing and entering your user
code. Using the arrow keys, navigate until you reach Event
Log and press . Using the arrow keys, navigate until you
reach Clear Log and press .
The same as above only this time you are navigating through
three menu levels.
The shortcut to a specific menu item from the main menu. In
this case, this is the shortcut for Set Date. These appear in
the procedures as an additional aid to menu navigation.
A shortcut to a specific item in a sub-menu. For example,
[#5] is the shortcut to Bell enable disable in the sub-menu
that is opened once you have selected the sensor you want
to program.
The symbol on a key that appears on the keypad
The text that actually appears on the LCD display (bold
italics).
Important note, please pay attention.
Table 1.1: Documentation Conventions
-5-
1.2: Specifications
General
Zones: 32 wireless zones (1 transmitter per zone), 1 hardwire zone (Zone 33)
Wireless Keyfobs: 8 (Controlled or Non-controlled)*
Wireless Keypads: 4
Repeaters: 4
Smartkeys (future option): 16 (Controlled or Non-controlled)
User Codes: 32
Arming Methods: Full, Part or Perimeter
Event Log: 256 event capacity, time and date stamped
Communications
Accounts: 3 (8-digit account number)
Telephone Numbers: 3 regular, RP Callback and Service Call (16-digits each)
Communication Interface Options: PSTN or GSM (optional expansion module required)
Home Automation
Control Medium: Power-line carrier
Protocol: X10
HA Units: 16 individually addressed
Power connection to the
unit should be according to
the national electrical code
for permanent installation.
The power supply should be fed
from a readily accessible
disconnect device.
Batteries shall be provided by a
distributor and replaced by
authorized service personnel.
!
Receiver
Type: Super-heterodyne, fixed frequency
Frequency: 868.35, 433.92 or 418MHz FM
Data Encryption: SecuriCode™
Electrical
Power Input: 230VAC, 50Hz
Backup Battery Pack: 7.2V/1.2Ah (6 x 1.2V Ni-MH rechargeable cells, size AA)
Fuse Ratings: 63mA/250V (AC protection fuse), 1A/250V (battery protection fuse)
PGM Relay Output Contact Rating: 100mA (max. load)
Internal Sounder: 105dB or 85dB
Tamper Switch: N.C.
Operating Temperature: 0-60°C
1.3: System Overview
The infinite is a full-featured wireless control panel that is expected to provide a solution
to the needs of most residential installations. This system has been developed based
upon a design concept geared towards easy installation and use. With this in mind, the
user interface is based on a simple, menu-driven model that suits the essential
requirements of both the user and installer alike. You can program the infinite on-site
using the on-board LCD keypad or off-site via a PC using the up/downloading software.
Central station communication and up/downloading employ either regular PSTN or highspeed cellular communication. SMS messaging provides an innovative method used for both
central station and Follow-me user monitoring. Additionally, SMS messages can be sent to
the panel enabling the user to send commands to the system from anywhere on the planet.
The panel’s home automation capabilities provide a wealth of features. The Home
Automation module interfaces with X10 units over the powerline network and grants the
user appliance control via a number of different media.
*
From firmware versions 2.11 and above, the system supports up to 19 keyfobs.
-6-
The following diagram shows the components that make up the system and the system’s
interaction with external communication networks.
Figure 1.1: System Architecture
-7-
1.4: Hardware Layout
The aim of this section is to acquaint you with the various circuit boards that make up the
system. Apart from the Main Board, each peripheral module is available as an optional
extra designed for installation inside the plastic housing.
Figure 1.2: System Layout
1.
2.
3.
4.
5.
Main Board
PSTN dialer module (optional)
Home Automation module (optional)
Cellular communications module (optional)
Backup battery pack
-8-
1.4.1: The Main Board
The Main Board is the brain of the system and connects to various peripheral modules
using a number of interface connectors. Additionally, the Main Board includes a
programmable output, a hardwire zone input, an external microphone/speaker
connection and a standard 9-pin serial port for PC programming.
Figure 1.3: Main Board
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
9-pin port for connection to PC
Header for plug-in Serial Interface board
Connector for on-board transmitter
DIP-switch for flash programming
Flat-cable interface connector to PSTN module
Interface connector to Home Automation module
Programming keypad connector
Status LED
Programmable relay output (100mA max. load)
Hardwire zone
External microphone and speaker connector
Flash programming connector for main board
Flat-cable interface connector to LCD keypad, internal speaker,
internal microphone and internal siren
Front tamper switch
AC power terminal block
Home Automation module terminal block
AC power protection fuse
Backup battery protection fuse
Flat-cable interface connector to GSM module
Backup battery connector
-9-
1.4.2: PSTN Module
The PSTN module provides the system with a standard dialer for central station
communications via the Public Switched Telephone Network (PSTN).
Alternative Telephone
Line Socket Option
Figure 1.4: PSTN Module
1.
2.
3.
4.
5.
6.
Flash programming connector
Status LED
Flat-cable interface connector to Main Board
Telephone line terminal block (Terminals 1 & 2: Outgoing line to telephone,
Terminals 3 & 4: Incoming line from telephone company)
Telephone socket for outgoing line to telephone
Telephone socket for incoming line from telephone company
1.4.3: Home Automation Module
The Home Automation module provides the system with an interface to the power-line
network, enabling control over 16 home automation units employing the X10 protocol.
Figure 1.5: Home Automation Module
1.
2.
3.
Interface connector to Main Board
Flash programming connector
Power-line terminal connections to Main Board (1 - Neutral; 2 - Live)
-10-
1.4.4: Cellular Communications Module
The Cellular Communications module enables the control panel to communicate via
cellular networks. This offers the ability to send or receive SMS messages, perform
up/downloading and implement cellular 2-way voice applications.
Figure 1.6: Cellular Communications Module
1.
2.
3.
4.
5.
SIM card holder
SIM card release
Status LED
Flash programming connector
Flat-cable interface connector to Main Board
-11-
Chapter Two: System Installation
2.1: Planning the Installation
When planning the installation, consider the following guidelines:
•
Whenever possible, mount the panel centrally in relation to wireless sensors.
•
Avoid installation in close proximity to sources of high noise or radio frequency
interference. For example, metal air conditioner/heater ducts and circuit breaker
boxes.
•
Minimize the distance between the panel and transmitters.
•
Minimize the number of obstacles between the panel and transmitters.
Figure 2.1: Minimizing Obstacles
•
Metal based construction materials, such as steel reinforced concrete walls,
reduce the range of radio transmissions.
Figure 2.2: Considering Construction Materials
•
The reduction of the RF signals’ strength is directly proportional to the thickness
of the obstacle, assuming that the obstacles are of identical material.
Figure 2.3: Considering Thickness of Obstacles
-12-
2.1.1: Considerations for Cellular installations
In addition to the above-mentioned guidelines for wireless installations, you must also
consider the physical location of the control panel if installing with the Cellular
Communications module – see 4.7.8: GSM Signal Strength.
2.2: Opening the Housing
To open the housing:
1. Remove the housing screw located
at the bottom of the front cover.
2. Using a screwdriver carefully
press the release tabs as shown
in Figure 2.4.
3. Lift the front cover away from the
back of the housing. You will
notice that the front cover is
attached to the back with
two fastening bands and the
keypad’s flat cable.
Housing
Screw
Figure 2.4: Opening the Housing
2.3: Mounting the Control Panel
Once you have decided where to locate the control panel according to the guidelines in
section 2.1: Planning the Installation, you are ready to mount the control panel.
For further information on the layout and function of each board within the housing, see
section 1.4: Hardware Layout.
To mount the control panel:
1. Open the housing as explained in section 2.2: Opening the Housing.
2. Disconnect the flat cable connecting the main panel to the keypad.
3. Detach the front and back covers by unfastening the bands that connect them.
4. Remove the backup battery pack. If you want to install the control panel with
back tamper, it is also necessary to remove the main board.
Upper
Mounting
Hole
Upper
Mounting
Hole
Location of
Back Tamper
Screw
Lower
Mounting
Hole
Lower
Mounting
Hole
Figure 2.5: Back Cover (Main Board and Battery Pack removed)
-13-
5.
6.
7.
8.
9.
10.
11.
,
12.
13.
Place the control panel in position against the wall and mark the upper and
lower mounting holes. If using the back tamper, also mark the hole for the back
tamper screw.
Install wall anchors in the appropriate positions.
Thread any required cables through the wiring hole on the back cover (e.g. AC
power and telephone line) and make any necessary wiring connections.
Mount the control panel to the wall using four screws.
Replace the Main Board and reconnect its peripheral modules.
Connect the flat cable and fastening bands to the front cover.
Apply AC power.
Always connect AC power before connecting the battery pack.
Connect the battery pack to the connector on the Main Board.
Position the front cover’s top holding hooks onto the back cover and snap the
front cover closed.
2.4: Back Tamper
The back tamper switch is an optional feature that provides
an extra safeguard in the event that the control panel is
removed from the wall.
The back tamper switch is located on the rear side of the
control panel’s Main Board and is constantly depressed by
the section of the back cover shown in Figure 2.6.
Figure 2.6: Perforated
Back Tamper Release
For this feature to operate, you must insert a screw into the back tamper mounting hole –
see section 2.3: Mounting the Control Panel. When the control panel is removed from the
wall, the screw causes the perforated section of the plastic to break and remain attached
to the wall. As a result, the back tamper switch is released and an alarm is generated.
-14-
Chapter Three: Basic System Operation
3.1: Front Panel Layout
The front panel provides a detailed interface for operating and programming the system.
The following diagram will familiarize you with the various elements on the front panel.
LCD
Display
System
Status
LEDs
Arming
Keys
Menu
Navigation
Keys
Alphanumeric
Keypad
Figure 3.1: Front Panel
3.2: System Status LEDs
The two LEDs, Armed and Power, provide essential information on the status of the
system.
If the Armed LED is…
Off
On
Flashing
It means…
The system is disarmed.
The system is armed.
An alarm has occurred. Alarm indication is cleared the next time that
an arming sequence is initiated or after the relevant event has been
viewed in the event log.
Table 3.1: Armed LED Indication
,
Alarm indication is not displayed after a silent panic alarm.
If the Power LED is…
Off
On
Flashing (slow)
It means…
Both AC and Battery power are disconnected.
System Power is OK.
Backup battery low.
Flashing (fast)
AC loss.
Table 3.2: Power LED Indication
-15-
3.3: Alphanumeric Keypad
The alphanumeric keypad on the front panel enables you to perform various operation
and programming tasks. Apart from the regular functions of a standard alphanumeric
keypad, the keypad offers a number of special functions. These functions are listed in the
following table.
Key
1
0
Special function
Used to enter symbols in descriptor editing.
Used to enter symbols in descriptor editing.
Used to cancel the current selection.
Used to return to the previous menu level.
Used to enter Menu mode.
Used to select the current menu item.
Used to signify the end of an entered value.
Toggles status in Zone Bypass/Unbypass function.
Used to switch Home Automation units on.
In descriptor editing, used to insert a space before the current character.
In phone number editing, used to enter “T”, “,”, “P”, “+”.
Toggles item descriptors and default names.
In the event log, toggles the time/date stamp.
Toggles AM and PM when setting the time in 12hr format.
Used to switch Home Automation units off.
In descriptor and phone number editing, used to delete the current character.
Used to scroll backwards in the current menu level
Used to scroll forwards in the current menu level.
During standby, used to scroll through the list of system trouble conditions.
Table 3.3: Keypad Functions
3.4: LCD Display
The LCD display provides you with a detailed interface for operation and programming.
3.4.1: Standby Mode
Standby mode can be defined as the state the
system is in when it is disarmed and not in Menu
mode. In Standby mode, the armed status,
system status or banner are displayed. If system
status is normal, the current time is displayed.
This…
DISARMED
FULL ARMED
PART ARMED
PERIMETER ARMED
FULL ARMING
PART ARMING
PERIMETER ARMING
DISARMED
11:22:02
Figure 3.2: Typical Standby Display
Means…
The system is disarmed.
The system has been armed using the displayed arming method.
The system is in the process of arming (displayed during exit delay).
Table 3.4: Armed Status
-16-
This…
ZONES IN ALARM
TAMPER ALARM
EXIT NOW 056
DISARM NOW 011
SYSTEM NOT READY
KEYPAD LOCKED
SYSTEM TROUBLE
Means…
Zones have been violated.
The system has been tampered with.
The exit delay is counting down (56 seconds remaining).
The entry delay is counting down (11 seconds remaining).
The system is not ready to arm, check that all doors and windows
are closed.
Five unsuccessful attempts were made to enter a user code, the
keypad is locked for 30 minutes.
A trouble condition has been detected, press
for further details.
Table 3.5: System Status
3.4.2: System Trouble Tones
In the event of system trouble, the infinite sounds a series of tones to alert the user. To
silence these tones, press
and scroll through the system trouble list displayed on the
LCD. When the trouble condition is restored, it is removed from the system trouble list.
,
For this feature to function, Trouble Tones must be enabled in programming
– see 8.4.1: Trouble Tones.
System trouble tones are not sounded from 10:00pm to 7:00am so as not to disturb
household members who may be asleep. However, you can program the system to
immediately annunciate telephone trouble at all times – see 8.4.2: Telephone Trouble
Tones.
3.5: Arming/Disarming
The following section explains how to arm and disarm the control panel using the LCD
keypad.
The infinite offers three arming modes that you can define to suit the application. Figure 3.3
illustrates the three arming modes. In each diagram, the protected area is shaded.
Full
Part
Perimeter
Figure 3.3: Arming Modes
The arming options are entirely flexible. You can program each sensor to be included in
any combination of the three arming modes – see section 7.6.2: Arm Set. Additionally,
each arming mode has a separate exit and entry delay.
The arming functions are only available while the system is in Standby mode.
-17-
3.5.1: Arming Keys
The Arming keys enable you to arm the system using any of the three arming methods:
Full, Part and Perimeter.
Full
Part
Perimeter
Figure 3.4: Arming Keys
3.5.2: Full Arming
Full arming is designed for when the occupant vacates the premises.
To fully arm the system:
1. Check if the system is ready to arm.
2. Press the Full arming key on the keypad.
3. If One-Key Arming is disabled, enter your user code.
3.5.3: Part Arming
Part arming is designed for when the occupant intends to remain inside one part of the
premises and secure another part.
To partially arm the system:
1. Check if the system is ready to arm.
2. Press the Part arming key on the keypad.
3. If One-Key Arming is disabled, enter your user code.
3.5.4: Perimeter Arming
Perimeter arming is designed for when the occupant intends to remain inside the
premises and secure the perimeter.
To arm the system’s perimeter:
1. Check if the system is ready to arm.
2. Press the Perimeter arming key on the keypad.
3. If One-Key Arming is disabled, enter your user code.
3.5.5: Combination Arming
The system allows you to activate a combination of two arming modes. If you Perimeter
arm the system, you may also activate Full or Part arming. Likewise, you can Perimeter
arm the system after activating Full or Part arming. It is not important which arming mode
you choose first.
You can activate the second arming mode during the exit delay of the first arming mode.
If the first exit delay expires, you cannot activate a second arming mode.
To arm the system using two arming modes:
1. Check if the system is ready to arm.
2. Activate the first arming mode.
3. If One-Key Arming is disabled, enter your user code.
-18-
4.
5.
,
While the exit delay of the first arming mode is counting down, activate the
second arming mode.
If One-Key Arming is disabled, enter your user code.
It is not possible to activate Full and Part arming modes simultaneously.
It is necessary to disarm first when changing from one arming mode to another arming mode.
The exit delays of the two arming modes are entirely independent. The moment an arming
mode is activated, its exit delay begins to count down. The entry delay depends on which
sensor was tripped first. For example, if the sensor is included in Full arming, the entry
delay for Full arming counts down – see 7.6.2: Arm Set. If the sensor is included in both
activated arming modes, the entry delay for Perimeter arming counts down.
If, due to open zones, the system is not ready to activate the second arming mode then
both arming methods are canceled. In this case, check that the relevant entrances are
secured and start the entire arming sequence again.
Disarming cancels both active arming modes.
3.5.6: Forced Arming
Forced arming enables you to arm the system when the system is not ready. For
example, if a door protected by a magnetic contact is open, you may arm the system on
condition that the door will be closed by the end of the Exit delay. If the door is still open
after the exit delay expires, an alarm is generated.
Two conditions enable you to perform Forced arming:
•
Forced arming is enabled – see section 9.3: Forced Arm.
•
The sensor that is causing the System Not Ready condition is Forced Arm
enabled – see section 7.6.5: Force Arm.
3.5.7: Disarming
When a sensor is tripped, the entry delay counts down; each arming method has its own
entry delay.
To disarm the system:
•
Enter a valid user code.
3.6: Remote Arming/Disarming via SMS
You can arm and disarm the system remotely by sending the SMS commands from a
cellular phone to the cellular communications module.
Each SMS command contains the following elements:
™
š
›
œ
SMS Command Descriptor (up to 43 characters of free text)
# (delimiter – separates the descriptor from the actual command)
User Code (4 digits)
Command (120=Disarm, 121=Full Arm, 122=Part Arm, 123=Perimeter Arm,
124=Full + Perimeter Arm, 125=Part + Perimeter Arm)
The following example shows the format of an SMS command for arming the system:
™
F
,
u
l
l
š
A
r
m
#
›
1
2
œ
3
4
1
2
1
While the SMS Command Descriptor is optional, you must start the SMS command with
the # symbol for the system to accept the command.
-19-
3.7: Front Panel Alarm Activation
In the event of an emergency, the user can generate three kinds of alarm from the front
panel.
To activate an SOS alarm:
•
Press both Home Automation keys simultaneously.
Figure 3.5: SOS Alarm Activation
To activate a Fire alarm:
•
Press keys 1 and 3 simultaneously.
Figure 3.6: Fire Alarm Activation
To activate a Medical alarm:
•
Press keys 4 and 6 simultaneously.
Figure 3.7: Medical Alarm Activation
-20-
Chapter Four: Advanced System Operation
Besides the basic arming functions described in the previous chapter, you can access
additional functions via the menu. This chapter describes these functions and the menu
navigation procedure.
4.1: Menu Navigation
Alphanumeric
Keypad
Menu
Navigation
Keys
HA Off Key
HA On Key
Service Call Key
Figure 4.1: On-board Keypad Layout
The LCD keypad’s friendly, menu-driven interface is designed to facilitate operation and
provide a gentler learning curve for first-time users. You can navigate through the menus
using the arrow navigation keys ( / ) and make simple yes/no decisions using the
and keys.
For example, perform the following procedure to navigate to Service, Speaker Test.
1.
2.
3.
4.
5.
6.
Press to enter Menu mode.
Enter an authorized user code; the first menu item, 1. Stop Comm., is
displayed.
Press
until 7. Service is displayed.
Press to enter the Service menu.
Press
until 4. Speaker Test is displayed.
Press to choose the displayed function.
As an alternative to scrolling through menu options, you may enter a function’s shortcut
once you have entered Menu mode. Shortcut numbers appear in square brackets in the
procedures throughout this manual.
,
Press the key to return to the previous menu level. Press this key when you are in the
main menu to exit Menu mode.
4.1.1: Menu Mode Timeout
Menu mode automatically terminates a certain amount of time after the last keystroke.
The duration of this timeout depends upon which code is used to enter the menu. Usually
the Menu Mode Timeout is two minutes but if you enter menu mode using the Installer
code, the timeout is extended to fifteen minutes.
4.2: Stop Communications
To stop communications:
•
From the main menu, select Stop Com. [1]; all communication buffers are
cleared and all pending messages are canceled.
-21-
4.3: Sensor Bypassing/Unbypassing
When a sensor is bypassed, it is ignored by the system and does not generate an alarm
when triggered.
To bypass or unbypass a sensor:
1. From the Bypass Zones menu, select Bypass/Unbyp. [21].
2. Using the arrow keys, scroll to the sensor you want to bypass or unbypass.
3. Press to change the bypass status.
4. Press ; Save Changes? is displayed.
5. Press to confirm the changed bypass status.
To unbypass all sensors:
1. From the Bypass Zones menu, select Unbypass All [22].
2. Press ; all sensors are unbypassed
,
All bypassed zones are automatically unbypassed when the system is disarmed.
A fire zone cannot be bypassed.
4.4: User Codes
The control panel supports up to 32 individual user codes. Each of these codes is four
digits long. Most system operations require you to enter a valid user code. The ability to
perform an operation is defined by your user code’s authorization level. These
authorization levels are pre-defined for each code as explained below.
Code 1: Master Code
The Master code is the highest user authorization level. With the Master code, you can
edit all other user codes except the Installer code, the Guard code and the Central
Station TWA Code. Additionally, the Master code grants access to the Event Log, the
Service menu and Home Automation Schedule programming. The Master code is a
“controlled” code. Arming and disarming using this code causes the panel to notify the
central station with an Arm/Disarm event message*.
,
The default Master code is 1234. Change this code immediately after installing the
system!
Codes 2-19: Controlled Codes
When you use a controlled user code for arming and disarming, the panel notifies the
central station with an Arm/Disarm event message.
Codes 20-25: Non-controlled Codes
Non-controlled codes do not cause the panel to send Arm/Disarm event messages to the
central station. The panel sends a Disarm message only if you use this code to disarm
the system after an alarm occurrence.
Codes 26-27: Limited Codes
A Limited code enables the user to issue a code that is valid for one day only. This code
automatically expires 24 hours after it has been programmed. These codes are
“controlled” in that their use for Arm/Disarm is notified to the central station.
*
Only if arm/disarm reporting is enabled during System Programming
-22-
Code 28: Duress Code
The Duress code is designed for situations where the user is being forced to operate the
system. This user code grants access to the selected operation, while sending a Duress
event message to the central station.
Code 29: User TWA Code
The User TWA code is designed to enable the user to establish Two-Way Audio
communication with the control panel at any time. This code can only be used for this specific
purpose and does not grant access to any additional system functions such as disarming.
Code 30: Central Station TWA Code
The Central Station TWA code is designed to enable the central station operator to
establish Two-Way Audio communication with the control panel after an alarm. This code
is valid for use for the first ten minutes after an alarm has occurred. This code can only
be used for this specific purpose and does not grant access to any additional system
functions such as disarming.
Code 31: Guard Code (for future use)
The Guard Code is a future option that is not available in the current firmware.
Code 32: Installer Code
The Installer code grants access to the Programming menu and the Service menu.
Additionally, this code enables you to view and clear the Event Log.
,
The default Installer code is 1111. Change this code immediately after installing the
system!
4.4.1: Editing User Codes
To edit a user code:
1. From the main menu select, User Codes [4].
2. Select the code you want to edit.
3. From the code’s sub-menu, select Edit Code [#1]; the 4-digit code is displayed
with the cursor flashing on the first digit.
4. Edit the code.
5. Press ; the new code is stored in the memory.
,
If you enter a code that is identical to an existing user code, the panel sounds an error
tone and the new code is not accepted.
Codes 1-30 can be edited only by the Master code. The Installer code and the Central
Station TWA Code can be edited only by the installer.
4.4.2: Deleting User Codes
To delete a user code:
1. From the main menu select, User Codes [4].
2. Select the code you want to delete.
3. From the code’s sub-menu, select Edit Code [#1]; the 4-digit code is displayed
with the cursor flashing on the first digit.
4. Enter 0000.
5. Press ; the code is deleted.
,
The Installer and Master codes cannot be deleted.
-23-
4.4.3: User Code Descriptors
Each user code can be assigned a 16-character descriptor. These descriptors help to
identify users in the event log and in SMS Follow Me messages.
To edit a code descriptor:
1. From the main menu, select User Codes [4].
2. Select a code.
3. From the code’s sub-menu, select Descriptor [#2].
4. Edit the descriptor using the alphanumeric keypad.
5. Press when you have finished editing.
4.5: Follow Me
The Follow Me feature is designed to notify the user that certain events have occurred.
The events that are sent to the Follow Me telephone number are those events that the
user is authorized to view in the event log; events that can be viewed only by the installer
are not sent to the Follow Me number – see Appendix C: Event Table. If using the TWA
Follow Me feature, the audio channel is opened after alarm events only.
To edit the Follow Me number:
1. From the main menu, select Follow Me [5].
2. Enter a telephone number for Follow Me communication. If using the SMS
Follow Me feature, this number must be for a cellular phone with the capability
to receive SMS messages.
,
You may only access Follow Me programming if the protocol for Account 3 is programmed
as SMS or TWA Follow Me.
4.6: Event Log
The event log records the last 256 events the system has undergone. The log uses the
FIFO (First In, First Out) method, automatically erasing the oldest event when the log is full.
To view the event log:
1. From the Event Log menu, select View Log [61]; a summarized version of the most
recent event is displayed. Press the key to view the time/date stamp or the
device/user number on the second row of the display.
2. Use the arrow keys to scroll through the events.
3. When you have finished viewing, press to exit the log.
The event log displays the following information for each event:
•
The event descriptor – a brief
™
description of the event that occurred.
FIRE ALARM
•
The zone where the event occurred.
14/11/03
12:34 R ›
š
•
Time/date stamp – the exact time the
™ Event Descriptor
event occurred.
š Time/Date Stamp
•
Report details – a single character
› Report Details
indicating whether the event was
reported to the central station. The
Figure 4.2: Detailed Event Log Display
options available are R: Report Sent,
F: Report Failed or N: No Report.
-24-
Figure 4.2 shows the detailed event log entry for a Fire alarm on November 14th 2003.
The event was successfully reported to the central station.
4.6.1: Event Log Authorization Levels
Every event that occurs is recorded in the event log. However, certain events are
intended for the installer only. Those events include various service messages that are of
little interest to the regular user. The View Log function requires you to enter either the
Master or Installer code. The events that are displayed depend on which code you use to
enter the log – see Appendix C: Event Table.
4.6.2: Clearing the Event Log
The Clear Log function erases all events from the log. After performing this function, a
Clear Log event is recorded in the log. The Clear Log function is accessible using the
Installer code only.
To clear the event log:
1. From the Event Log menu, select Clear Log [62]; the OK? confirmation
message is displayed.
2. Press ; the log is cleared.
,
For certain versions of the infinite software, the Clear Log function may be disabled.
4.7: Service Menu
The Service menu is accessible using either the Installer or Master code. This menu
includes various functions that enable you to test the system effectively.
4.7.1: Set Time & Date
The time and date are used to time stamp events in the event log. Additionally the time is
also displayed on the LCD display.
To set the time:
1. From the Service menu, select Set Time/Date, Set Time [7011].
2. Enter the current time.
3. Press ; the time is modified.
To set the date:
1. From the Service menu, select Set Time/Date, Set Date [7012].
2. Enter the current date.
3. Press ; the date is modified.
,
The format of the time and date is defined in the System Options – see 9.14: Time/Date
Format. If you are setting the time in 12hr format, use the key to toggle between AM and PM.
4.7.2: External Siren Test
To test the external siren:
•
From the Service menu, select Ext. Siren Test [702]; the external siren is
sounded briefly.
4.7.3: Internal Siren Test
To test the internal siren:
•
From the Service menu, select Int. Siren Test [703]; the internal siren is
sounded briefly.
-25-
4.7.4: Speaker Test
To perform a Speaker test:
•
From the Service menu, select Speaker Test [704]; a short sequence of chimes
are sounded from the speaker.
4.7.5: Walk Test
To initiate Walk Test mode:
1. From the Service menu, select Walk Test [705]; a list of registered sensors
appears.
2. Trigger each sensor; when the system receives a successful transmission from
a sensor, the sensor is removed from the list.
3. When all the sensors are removed from the list, End Walk Test is displayed.
4. Press to exit Walk Test mode.
4.7.6: Transmitters
The Transmitters menu offers two utilities that serve as a valuable aid during installation.
The first utility, TX List, is a scrollable inventory of all registered transmitters and their last
reported status.
To view the TX list:
1. From the Service menu, select Transmitters, TX List [7061]; the first transmitter
on the list is displayed.
2. Using the arrow buttons, scroll through the transmitter list.
3. When you have finished viewing, press to exit the list.
The TX list displays the following information for
each transmitter:
•
The transmitter’s descriptor.
•
The signal strength of the last received
transmission.
•
An abbreviation indicating the last
received status of the transmitter – see
Table 4.1.
This…
OK
TA
BT
OS
NA
™
š
FRONT DOOR
S=6 OK ›
™
Descriptor
š
Signal Strength
›
Status
Figure 4.3: TX List Display
Means…
The transmitter is functioning correctly
Tamper condition
Battery low
The transmitter is out of synchronization
The transmitter is inactive – see section 7.4: Supervision Time
Table 4.1: Transmitter Status Abbreviations
,
In most cases, an “out of synchronization” condition indicates that an unauthorized
attempt at grabbing the transmission has occurred – i.e. a previous transmission has been
recorded and sent by somebody trying to violate the system.
The second utility, TX Test, enables you to identify transmitters and test their signal
strength.
In TX Test mode, each time a transmission is received, the activated transmitter is
displayed.
-26-
If you enter this function using the Master code, a
chime is sounded every time a transmission is
received. If you enter this function using the
Installer code, a sequence of tones are sounded
indicating the transmitter’s signal strength – see
Table 4.2. This feature helps you to determine the
best location to install a transmitter.
Signal Strength
0-2
3-5
6-8
8-9
Tones
1 Tone
2 Tones
3 Tones
4 Tones
Table 4.2: Signal Strength Tones
To initiate TX Test mode:
1. From the Service menu, select Transmitters, TX Test [7062].
2. Activate a transmitter; the transmitter’s details are displayed.
3. When you have finished, press to exit TX Test mode.
4.7.7: Audio Volume
To adjust the sensitivity of the microphone and the volume of the speaker:
1. Establish a two-way audio connection.
2. From the Service menu, select Audio Volume [707].
3. Adjust the setting according to the following table.
Press…
1
4
3
6
To…
Increase microphone sensitivity
Reduce microphone sensitivity
Increase speaker volume
Reduce speaker volume
Table 4.3: Voice Level Adjustment
4.
Press ; the new settings are stored in the memory.
4.7.8: GSM Signal Strength
You can measure the GSM signal strength using the system’s RSSI (Received Signal
Strength Indication) meter. This function enables you to calculate the optimal location to
install the control panel with the Cellular Communications module.
To view the GSM signal strength reading:
•
From the Service menu, select GSM Signal [708]; the signal strength of the
cellular network is displayed.
This Reading…
8 to 9
5 to 7
Less than 5
Means…
The location is good
The location is acceptable
Unacceptable – choose another location!
Table 4.4: GSM Signal Strength
4.7.9: Display Version
To display the system’s software and hardware versions.
•
From the Service menu, select Version [709]; the hardware (HW) and software
(SW) versions are displayed.
-27-
4.7.10: Enable Remote Programming
The system offers various remote programming access options that are explained in
section 10.3.4: RP Access Options. If “User Initiated” RP access is selected,
communication may be established only if the user manually enables remote
programming.
To manually enable remote programming.
•
From the Service menu, select Enable RP [710]; a 30-minute time window is
opened during which RP communication may be established.
4.7.11: Global Chime
The Chime feature causes the internal siren to ring when specific zones are triggered.
Using the Global Chime option, you can enable or disable this feature for all zones that
are defined as Chime enabled – see 7.6.4: Chime.
To enable or disable Global Chime:
1. From the Service menu, select Global Chime [711].
2. Select either Enable or Disable.
3. Press when the desired setting is displayed.
,
Though the Service menu is accessible to the Master and Installer only, Global Chime can
also be accessed via a convenient shortcut without needing to enter a valid user code. To
access the Global Chime option from Standby mode, press
then .
-28-
Chapter Five: Two-Way Audio
The infinite control panel offers a range of Two-Way Audio features that can be used for
applications such as alarm verification and medical assistance. This chapter explains
these features, their operation procedures and programmable options.
Two-Way Audio communication can be separated into two fundamental groups; incoming
and outgoing calls. These groups differ in their associated audio features.
5.1: Incoming Calls
The control panel can receive incoming calls from either the user or central station
operator. Users may use this feature as a convenient way of contacting their family or to
check their home when they are away. Additionally, the monitoring service can contact
the user in the event of an emergency or use this feature for listen-in alarm verification.
For any of the incoming Two-Way Audio features to function, Incoming TWA must be
enabled in the Communication Options section of the Programming menu.
5.1.1: User Code Verification
To prevent unauthorized attempts to connect with the control panel, there are two user
codes designed for use with the Two-Way Audio feature. The User TWA code enables
the user to establish Two-Way Audio communication at any time. The Central Station
TWA Code is only valid for a ten-minute period following an alarm.
5.1.2: Incoming Calls via PSTN
In the case of PSTN communication, the control panel often shares a line with regular
telephone handsets, an answering machine or a fax machine. It is therefore important
that the control panel distinguish between calls so that it knows when to pick up the
relevant call. For this purpose the infinite employs a double call method.
To connect to the control panel using the double call method:
1. Dial the telephone number of the line connected to the control panel.
2. Wait for two or three rings and hang-up.
3. Wait at least five seconds and dial the number again; on the second ring, the
control panel picks up and sounds two DTMF tones.
5.1.3: Incoming Calls via a Cellular Network
The Cellular Communications Module has its own individual telephone number and
therefore, the double call method is not needed. In this case, the user or central station
operator may call the control panel directly.
5.1.4: Two-Way Audio Call Procedure
The following procedure explains how to make a Two-Way Audio call. The conditions and
procedure differ when using PSTN or Cellular communication. For further information,
read sections 5.1.1, 5.1.2. and 5.1.3 above.
To make a Two-Way Audio call:
1. Call the control panel either using the double call method (PSTN) or directly
(Cellular); when the control panel picks up, two DTMF tones are sounded.
2. Enter the User TWA or Central Station TWA code on your telephone within 15
seconds.
,
Do not enter your user code until you hear the two DTMF tones. Any digits entered before
the tones are sounded are disregarded by the system.
-29-
3.
4.
5.
If the TWA mode is defined as “Simplex” (see 10.7.4: TWA Mode), the audio
channel opens in Listen mode (microphone active/speaker mute). To switch to
Speak mode, press 1 on your telephone. To switch back to Listen mode, press
0 on your telephone.
The duration of the call is determined by the TWA Timeout. Ten seconds before
the timeout expires, two short DTMF tones are sounded. To extend the call,
press 7 on your telephone. This command restarts the timeout.
To disconnect before the end of the timeout, press “@” then “#” on your telephone.
5.1.5: Siren Muting
The siren is muted during Two-Way Audio communication. At the end of the call, the
siren is re-activated (if the Siren Cut-Off has not yet expired). You can cancel the reactivation of the siren by pressing “9” on your telephone during the call.
5.2: Outgoing Calls
The infinite control panel can make Two-Way Audio calls to the user or central station in
the event of an alarm. This feature is designed for applications such as alarm verification,
panic and medical emergency.
5.2.1: Service Call
The Service Call feature enables the user to establish a two-way audio
connection with the central station operator. For further information on
how to program this feature, see section 10.4: Service Call.
To initiate a Service Call:
•
Press and hold down the Service Call key for a few seconds.
Figure 5.1:
Service Call Key
If the TWA mode is defined as “Simplex” (see 10.7.4: TWA Mode), the audio channel
opens in Listen mode (microphone active/speaker mute). The operator may switch to
Speak mode, by pressing 1 on their telephone. Pressing 0 switches back to Listen mode.
5.2.2: TWA Alarm Reporting
In the event of Burglary, Fire and Medical alarms, the control panel is able to report the
events and then stay on the line after ACK 2 is received. This allows the operator to
verify the alarm or provide assistance in the event of an emergency.
For this feature to function, you must enable Two-Way Audio for both the account and
the event group.
The sequence for Two-Way Audio during alarm reporting is as follows:
1. An alarm event is sent to the central station and acknowledgment is received
(ACK 2).
2. If Two-Way Audio is enabled for the account and event group, the control panel
stays on the line and opens the audio channel.
3. If the TWA mode is defined as “Simplex” (see 10.7.4: TWA Mode), the audio
channel opens in Listen mode (microphone active/speaker mute). The operator
may switch to Speak mode, by pressing 1 on their telephone. Pressing 0
switches back to Listen mode.
4. The duration of the call is determined by the TWA Timeout. Ten seconds before
the timeout expires, two short DTMF tones are sounded. To extend the call,
press 7 on your telephone. This command restarts the timeout.
5. To disconnect before the end of the timeout, press “@” then “#” on your telephone.
-30-
If multiple events are sent, the control panel sends all the events before opening the
audio channel.
,
When using the SIA protocol for event reporting, this feature functions in “listen-in” mode
only.
5.2.3: TWA Follow-Me
The TWA Follow-Me feature is designed to establish a Two-Way Audio connection with
the user in the event of an alarm. For this feature to function, the account’s protocol must
be defined as TWA Follow-Me.
The sequence for a Two-Way Audio Follow-me call is as follows:
1. An alarm occurs.
2. The control panel dials the programmed telephone number and sounds two
DTMF tones when you pick up the call.
3. Press any key on your telephone; the control panel opens the audio channel.
,
If you press 9 to answer the call, the control panel simultaneously cancels the siren when
opening the audio channel.
4.
If the TWA mode is defined as “Simplex”, (see 10.7.4: TWA Mode), the audio
channel opens in Listen mode (microphone active/speaker mute). To switch to
Speak mode, press 1 on your telephone. To switch back to Listen mode, press
0 on your telephone.
The duration of the call is determined by the TWA Timeout. Ten seconds before
the timeout expires, two short DTMF tones are sounded. To extend the call,
press 7 on your telephone. This command restarts the timeout.
To disconnect before the end of the timeout, press “@” then “#” on your telephone.
5.
6.
-31-
Chapter Six: Home Automation Control
The purpose of this chapter is to explain the various methods used to control X10 Home
Automation (HA) units installed around the home. For further information on the X10
protocol and the choice of options that are available in programming, see Chapter
Eleven: Home Automation Programming.
6.1: Keypad Control
Using either the LCD or the wireless keypad, you can control HA units with the dedicated
Home Automation keys – see Figure 6.1.
On
Off
Figure 6.1: LCD Keypad Home Automation Keys
To control HA units via the LCD keypad:
1. Press one of the two Home Automation keys on the keypad (On or Off).
2. Enter the number of the required HA unit in two-digits (01-16); the command is
sent to the HA unit.
6.2: Keyfob Control
You can control up to two different HA units using any of the four button keyfobs
registered to the system. For further information on how to assign keyfob buttons to HA
units, see section 7.7.2: Button Assignment.
6.3: SMS Control
You can send On and Off commands to HA units using SMS messages sent from a
cellular phone to the cellular communications module. For this feature to function
correctly, SMS control must be enabled for the specific HA units you want to control –
see section 11.2.5: SMS Control.
6.3.1: SMS Command Format
Each SMS command contains the following elements:
SMS Command Descriptor (up to 43 characters of free text)
# (delimiter – separates the descriptor from the actual command)
User Code (4 digits)
Command (0=Off, 1=On)
Device Number (HA Units: 01-16)
™
š
›
œ

The following example shows the format of an SMS command to switch on a water boiler
controlled by HA unit 8.
™
B
,
o
i
l
e
š
r
O
n
#
›
1
2
œ
3
4
1

0
8
While the SMS Command Descriptor is optional, you must start the SMS command with
the # symbol for the system to accept the command.
-32-
6.3.2: SMS Confirmation Message Format
After an SMS command is executed by the system, a message is returned to the sender
– see 11.4: SMS Confirmation. This message includes the HA unit’s descriptor and the
command that was sent.
The following example shows the confirmation message the sender receives for the
sample command from the previous section.
B
o
i
l
e
r
-
O
N
6.4: Scheduling
Scheduling allows you to program the panel to send On/Off commands to HA units at
specific times. You can also program the days of the week that the schedule is active.
6.4.1: On Time
To edit an HA unit’s “On” Time:
1. From the main menu, select HA Schedules [8].
2. Select an HA unit.
3. From the X10 unit’s sub-menu, select On Time [#1].
4. Enter a time (HH:MM).
5. Press when the desired setting is displayed.
6.4.2: Off Time
To edit an HA unit’s “Off” Time:
1. From the main menu, select HA Schedules [8].
2. Select an HA unit.
3. From the HA unit’s sub-menu, select Off Time [#2].
4. Enter a time (HH:MM).
5. Press when the desired setting is displayed.
6.4.3: Weekly Schedule
To program the days of the week that the schedule is active:
1. From the main menu, select HA Schedules [8].
2. Select an HA unit.
3. From the HA unit’s sub-menu, select Schedule [#3].
4. Use keys 1 to 7 to toggle the days on and off.
Press…
1
2
3
4
5
6
7
To toggle…
Sunday
Monday
Tuesday
Wednesday
Thursday
Friday
Saturday
Table 6.1: Weekly Schedule
5.
Press when the desired setting is displayed.
-33-
Chapter Seven: Devices
This chapter explains how to register devices to the system and the programming options
for each device. For further information, please refer to the installation instructions
included with each device.
7.1: Device Registration
For the system to recognize individual devices, each device must be registered to the
system. For example, if the device is a wireless transmitter, registration enables the system
to identify the source of a received transmission. Each device has an individual encrypted
ID code. Registering the device to the system familiarizes the system with this code.
,
It is not necessary to register hardwire sensors connected to Zone 33.
To register a device to the system:
1. From the Programming menu, select Devices [91].
2. Select the type of transmitter you want to register. For example, if you want to
register a wireless sensor to a zone, select Zones.
3. Select the specific device you want to register (for example, Zone 4); the system
initiates Registration mode. During Registration mode, the system waits for two
transmissions from the device.
,
If a device has already been registered at the required location, the system will not initiate
Registration mode. If the device has already been registered at another location, attempts
to register are ignored by the system
4.
Register the device – refer to each device’s installation instructions in Appendix
B for further details.
When two transmissions have been received, Save? is displayed.
Press to confirm registration, or to cancel.
5.
6.
7.2: Device Descriptors
You can assign a 16-character descriptor to each device except the siren. These
descriptors help identify the devices when you operate and program the system.
To edit a device descriptor:
1. From the Programming menu, select Devices [91].
2. Select a device type.
3. From the device’s sub-menu, select Descriptor.
4. Edit the descriptor using the alphanumeric keypad.
5. Press when you have finished editing.
-34-
7.3: Device Deletion
When you want to remove a device from the system, you have to delete the device. It is
important to delete unused devices for two reasons. Firstly, you have to delete a device
before you can register a new transmitter in its place. Secondly, if the device is a wireless
sensor, it is important to delete the device so that the system will not react to the
transmitter’s failure to send supervision signals.
To delete a device:
1. From the Programming menu, select Devices, [91].
2. Select the type of wireless device you want to delete.
3. From the device’s sub-menu, select Delete.
4. Press to confirm; the device is deleted.
7.4: Supervision Time
The sensors in Electronics Line 3000’s supervised wireless range send a supervision
signal approximately one hour after its last transmission. If the system does not receive
supervision signals from a specific transmitter, the transmitter is regarded as inactive.
The amount of time after which a transmitter is considered inactive is called the
Supervision Time.
To program the Supervision Time:
1. From the Programming menu, select Devices, Superv. Time [916].
2. Enter a supervision time between 04:00 and 23:59 hours.
,
For systems with Class 2 approval, the sensors transmit supervision signals
approximately every 14 minutes and the system’s default supervision time is one hour.
If using these versions, do not change the default Supervision Time!
7.5: Re-Synchronization
Transmissions that are out of synchronization are rejected by the system. For example, it
is not possible to arm or disarm the system using a keyfob that is out of synchronization.
In the event that a transmitter is out of synchronization, it is possible to re-synchronize
the transmitter and restore normal operation.
To re-synchronize transmitters:
1. From the Programming menu, select Devices, TX Re-synch [917]; a 10-minute
time window is opened.
2. During the 10-minute time window, if a transmission is received that is out of
synchronization, the transmitter is re-synchronized.
-35-
7.6: Zones
The infinite includes 33 security zones. Zones 1-32 are intended for wireless sensors.
One sensor can be registered to each wireless zone. The system supports Electronics
Line 3000’s supervised wireless range of transmitters that includes various PIR sensors,
magnetic contacts and smoke detectors. All these transmitters send supervision signals
to the panel’s receiver in order to indicate that the transmitter is functional.
Zone 33 is an on-board hardwire zone. This zone is programmed in the same way as the
wireless zones with the exception of registration and deletion.
This section explains the sections of programming exclusive to sensors. For information
on registration, descriptor editing and deletion, see sections 7.1, 7.2 and 7.3,
respectively.
7.6.1: Zone Type
The zone type defines the type of alarm the system generates when the sensor is tripped.
To program a zone type:
1. From the Programming menu, select Devices, Zones [911].
2. Select the sensor you want to program.
3. From the sensor’s sub-menu, select Zone Type [#02].
4. Select a zone type from Table 7.1.
Zone Type
Normal
Entry/Exit
Follower
Panic
Medical
Fire
24Hr
24Hr-X
(future use)
Environmental
Not Used
Description
When the system is armed, this zone instantly generates an alarm
when triggered.
When the system is armed, this zone initiates the entry delay when
triggered. If the system is not disarmed by the time the entry delay
expires, an alarm is generated.
If an Entry/Exit zone is triggered first, Follower zones do not generate
an alarm when triggered during the entry delay. If the system is not
disarmed by the end of the entry delay, the Follower zone generates
an alarm. A Follower zone instantly generates an alarm if the entry
delay is not active.
Panic zones are always active, regardless of whether the system is
armed or not. When a Panic zone is triggered, a Panic alarm is
generated.
Medical zones are always active. When triggered, these zones
generate a Medical alarm.
These zones are always active. When a fire sensor is triggered, the
zone generates a Fire alarm.
This zone type produces a burglary alarm when triggered, even when
the system is disarmed.
The 24Hr-X zone is a future option that is not available in the current
firmware.
This zone type is intended for environmental detectors such as flood
and gas sensors. When triggered, the alarm that is generated
depends upon the type of sensor registered to the zone.
Environmental zones are always active.
This zone type disables the sensor output. All alarm transmissions
from the sensor are ignored though the sensor may still be used to
activate HA units in Home Automation applications.
Table 7.1: Zone Type Options
-36-
7.6.2: Arm Set
The Arm Set option allows you to define the arming methods in which the zone is included.
To program the Arm Set option:
1. From the Programming menu, select Devices, Zones [911].
2. Select the sensor you want to program.
3. From the zone’s sub-menu, select Arm Set [#03]; the zone’s current Arm Set
setting is displayed.
Arm Set
1 (F)
2 (P)
3 (PE)
Description
The zone is included in Full arming.
The zone is included in Part arming.
The zone is included in Perimeter arming.
Table 7.2: Arm Set Options
4.
5.
,
Use the keys 1, 2 and 3 to toggle the current setting.
Press when the desired setting is displayed.
It is not necessary to program this option for Panic, Medical, Fire, 24Hr and Environmental
zones.
7.6.3: Bell
Each zone can be programmed to activate the siren when triggered or to generate a
silent alarm where only a message is sent to the central station.
To program the Bell option:
1. From the Programming menu, select Devices, Zones [911].
2. Select the zone you want to program.
3. From the zone’s sub-menu, select Bell [#05]; the zone’s current Bell setting is
displayed.
4. Select either Enable or Disable.
,
Fire zones always activate the siren regardless of what is programmed for this option.
If the bell is disabled for Panic zones, this also disables all forms of alarm indication from
the on-board keypad in the event of a Panic alarm.
7.6.4: Chime
When Chime is enabled, triggering the zone when the system is disarmed causes the
internal siren to chime.
To program the Chime option:
1. From the Programming menu, select Devices, Sensors [911].
2. Select the zone you want to program.
3. From the zone’s sub-menu, select Chime [#06]; the zone’s current Chime
setting is displayed.
4. Select either Enable or Disable.
-37-
7.6.5: Force Arm
Force arming enables you to arm the system when the system is not ready. For example,
a door that is protected by a magnetic contact is open. You may arm the system on
condition that the zone is defined as Force Arm enabled. This door must be closed by
the end of the Exit delay otherwise an alarm is generated. If the magnetic contact’s zone
is defined as Force Arm disabled, the system will not be ready to arm until you close the
door.
To program the Force Arm option:
1. From the Programming menu, select Devices, Zones [911].
2. Select the zone you want to program.
3. From the zone’s sub-menu, select Force Arm [#07]; the zone’s current Force
Arm setting is displayed.
4. Select either Enable or Disable
,
For the Force Arm feature to function, you must also enable Force Arming in the System
options (see 9.3: Forced Arm).
7.6.6: Swinger
A zone defined as Swinger enabled can generate only a limited number of alarms
during a specific time period. The Swinger setting is defined in System Options – see
9.1: Swinger Setting.
To program the Swinger option:
1. From the Programming menu, select Devices, Zones [911].
2. Select the zone you want to program.
3. From the zone’s sub-menu, select Swinger [#08]; the zone’s current Swinger
setting is displayed.
4. Select either Enable or Disable.
,
Do not enable the Swinger option for zones that are always active (Panic, Medical, Fire
and 24-hr zones).
7.6.7: Repeater
The EL-2635 repeater is an additional module that extends the range of the wireless
transmitters. For a sensor to use the repeater to relay transmissions to the system, you
must define the Repeater option for its zone as “Use Repeater”.
To program the Repeater option:
1. From the Programming menu, select Devices, Zones [911].
2. Select the zone you want to program.
3. From the zone’s sub-menu, select Repeater [#09]; the zone’s current Repeater
setting is displayed.
4. Select either No Repeater or Use Repeater.
-38-
7.7: Keyfobs
The infinite supports two types of keyfob transmitter, EL-2611 and EL-2614. You can
register up to eight keyfobs to the system*. Figure 7.1 illustrates these transmitters and
the functions assigned to their buttons. For information on registration, descriptor editing
and deletion, see sections 7.1, 7.2 and 7.3, respectively.
Arm
Disarm
B1:
Part
B2:
Perimeter
Medical
Emergency
EL-2611
EL-2614
Figure 7.1: Keyfob Button Assignments
The following sections explain the programming options exclusive to the EL-2614 keyfob
transmitter. These programming options are not relevant to the EL-2611.
7.7.1: Keyfob Type
You can define each registered keyfob as Controlled or Non-controlled. A Controlled
keyfob causes the system to send arm/disarm event messages to the central station.
Non-controlled keyfobs never send arm messages and send a disarm message only if
the system is disarmed after an alarm occurrence.
To program a keyfob type:
1. From the Programming menu, select Devices, Keyfobs [912].
2. Select the keyfob you want to program.
3. From the keyfob’s sub-menu, select Type [#2]; the current setting is displayed.
4. Select either Controlled or Non-controlled.
7.7.2: Button Assignment
The EL-2614 includes two buttons (B1 and B2) that you can program individually. The
default functions for B1 and B2 offer different arming methods. Alternatively, you can
program these buttons to control a specific HA unit.
To program buttons B1 and B2:
1. From the Programming menu, select Devices, Keyfobs [912].
2. Select the keyfob you want to program.
3. From the keyfob’s sub-menu, select either B1 Assign [#4] or B2 Assign [#5].
4. Select the HA unit you want the button to control (01-16) or enter 00 to program
the button’s default function.
The default functions are as follows:
B1: Part arming
B2: Perimeter arming
*
From firmware versions 2.11 and above, the system supports up to 19 keyfobs.
-39-
7.7.3: SOS Panic Alarm Activation (EL-2614)
Using the four-button keyfob, you can activate
an SOS Panic alarm by pressing two buttons
simultaneously. Figure 7.2 illustrates how to
activate an SOS Panic alarm on the EL-2614
wireless keyfob.
Figure 7.2: SOS Panic
Alarm Activation
7.8: Keypads
Up to four wireless keypads are supported by the system. With the exception of the
Cancel key, operation is identical for both EL-2620 and EL-2640 keypads.
For information on registration, descriptor editing and deletion, see sections 7.1, 7.2 and
7.3, respectively.
HA
On Key
Numeric
Keypad
Arming
Keys
HA
Off Key
Cancel
Key
Figure 7.3: EL-2620 Keypad Layout
7.8.1: Keypad SOS Panic Alarm Activation
Using any of the wireless keypads, you can
activate an SOS Panic alarm by pressing the
Full and Perimeter arming keys simultaneously.
Figure 7.4 illustrates how to activate an SOS
Panic alarm on the EL-2620 wireless keypad.
Figure 7.4: SOS Panic
Alarm Activation (EL-2620)
-40-
7.9: Repeaters
Repeaters are designed to extend the wireless range of the control panel. Up to four
repeaters may be registered to the system with a maximum of eight transmitters
associated with each receiver. For information on registration, descriptor editing and
deletion, see sections 7.1, 7.2 and 7.3, respectively.
7.10: External Siren
The control panel may include an optional on-board transmitter that sends alarm and arm
status information to the wireless siren’s receiver. This transmitter must be registered to
the siren’s receiver.
To register the on-board transmitter to the siren’s receiver:
1. Set the siren’s receiver to Registration mode – refer to the siren’s installation
instructions for further information.
2. Activate the siren using the External Siren Test feature – see 4.7.2: External
Siren Test.
3. Activate the siren again; the on-board transmitter is registered to the siren’s
receiver.
When installing 2-way sirens, the siren also includes a transmitter that must be registered
to the system. For information on registration and deletion, see sections 7.1 and 7.3,
respectively.
7.10.1: Siren Type
The control panel supports both 1-way and 2-way sirens. For this feature to function
correctly, you must define the siren type in programming.
To program the siren type:
1. From the Programming menu, select Devices, Siren, Ext. Siren Type [9152].
2. Select a siren type or No Ext. Siren if no siren is installed.
7.10.2: Siren Delay
The Siren Delay is the period of time during which the external siren is not sounded after
an alarm is triggered by normal, follower or 24Hr zones. This feature is implemented only
when the system is not fully armed. During the Siren Delay, only the internal siren is
sounded and an alarm report is not sent until the delay has expired. This gives the user
enough time to disarm in the event that the alarm was accidentally triggered during Part
or Perimeter arming. If the user disarms the system during the Siren Delay, an event
message is not sent to the central station.
To program the Siren Delay time:
1. From the Programming menu, select Devices, Siren, Siren Delay [9153].
2. Enter a Siren Delay time (00-63 seconds).
3. Press when the desired setting is displayed.
-41-
7.10.3: Siren Cut-Off
The Siren Cut-Off is the period of time the siren is activated after an alarm has occurred.
You may program a Siren Cut-Off time of between 001-254 seconds. If the Siren Cut-Off
is programmed as 255 (continuous), the external siren will continue to sound until its
internal cut-off time expires. In this case, the control panel’s internal siren will sound for
255 seconds.
To program the Siren Cut-Off time:
1. From the Programming menu, select Devices, Siren, Cut-Off [9154].
2. Enter a Siren Cut-Off time (001-254 seconds or 255 for continuous external
siren operation).
3. Press when the desired setting is displayed.
7.11: Smartkeys (for future use)
Smartkeys enable the user to arm and disarm the system without needing to enter a
code. You can register up to 16 smartkeys to the system. For information on registration,
descriptor editing and deletion, see sections 7.1, 7.2 and 7.3, respectively.
7.11.1: Smartkey Type
You can define each registered smartkey as Controlled or Non-controlled. A Controlled
smartkey causes the system to send arm/disarm event messages to the central station.
Non-controlled smartkeys never send arm messages and send a disarm message only if
the system is disarmed after an alarm occurrence.
To program the smartkey type:
1. From the Programming menu, select Devices, Smartkeys [918].
2. Select the smartkey you want to program.
3. From the smartkey’s sub-menu, select Type [#2]; the current setting is
displayed.
4. Select either Controlled or Non-controlled.
-42-
Chapter Eight: Entry/Exit Timers and Arming Tones
This chapter explains how to program the time of the Entry/Exit delays and the tones
sounded by the two sirens during Exit/Entry delays, arming and disarming.
8.1: Entry/Exit Delay
The Entry/Exit delay timers determine the amount of time the user has to arm or disarm the
system before an alarm is activated. When these timers count down, the internal siren
sounds a series of tones throughout the delay.
You can program separate Entry and Exit delays for each arming method.
To program Exit delay timers:
1. From the Programming menu, select Entry/Exit, Exit Delays [921].
2. Select the Exit delay you want to program: Full [#1], Part [#2] or Perimeter [#3].
3. Enter a delay time (000-255 seconds).
4. Press when the desired setting is displayed.
To program Entry delay timers:
1. From the Programming menu, select Entry/Exit, Entry Delays [922].
2. Select the Entry delay you want to program: Full [#1], Part [#2] or Perimeter [#3].
3. Enter a delay time (000-255 seconds).
4. Press when the desired setting is displayed.
8.2: Arm on Exit
The Arm on Exit feature cancels the unnecessary remainder of the Exit delay that
continues to count down after the user has vacated the premises. This feature
automatically arms the system when an Entry/Exit zone is closed during the Exit delay.
To program the Arm on Exit option:
1. From the Programming menu, select Entry/Exit, Arm On Exit [923].
2. Select Enable or Disable
8.3: Arming Tones
Arming tones are the tones sounded by either from the internal or external sirens when
arming and disarming the system. Each set of tones can be enabled or disabled
according to the requirements of the installation.
8.3.1: Exit Delay Tones
To program external siren tones during the Exit delay:
1. From the Programming menu, select Tones, Exit Tones, External Tones [9311].
2. Select Enable or Disable.
To program internal siren tones during the Exit delay:
1. From the Programming menu, select Tones, Exit Tones, Internal Tones [9312].
2. Select No Tones, Four Tones or Continuous Tones.
-43-
8.3.2: Entry Delay Tones
To program external siren tones during the Entry delay:
1. From the Programming menu, select Tones, Entry Tones, External Tones
[9321].
2. Select Enable or Disable.
To program internal siren tones during the Entry delay:
1. From the Programming menu, select Tones, Entry Tones, Internal Tones
[9322].
2. Select No Tones, Four Tones or Continuous Tones.
8.3.3: Arming Tones
To program external siren tones on arming:
1. From the Programming menu, select Tones, Arm Tones, External Tones [9331].
2. Select Enable or Disable.
To program internal siren tones on arming:
1. From the Programming menu, select Tones, Arm Tones, Internal Tones [9332].
2. Select Enable or Disable.
8.3.4: Disarming Tones
To program external siren tones on disarming:
1. From the Programming menu, select Tones, Disarm Tones, External Tones
[9341].
2. Select Enable or Disable.
To program internal siren tones on disarming:
1. From the Programming menu, select Tones, Disarm Tones, Internal Tones
[9342].
2. Select Enable or Disable.
8.3.5: Home Automation Tones
Home Automation tones are sounded when you control HA units using keypads or keyfob
transmitters.
To program internal siren Home Automation tones:
1. From the Programming menu, select Tones, HA Tones [935].
2. Select Enable or Disable.
-44-
8.4: System Trouble Tones
System trouble tones are sounded to provide an audible indication that a system trouble
condition exists. On hearing these tones the user is then able to determine which trouble
condition is present from the LCD keypad on the front panel. For additional information,
see 3.4.2: System Trouble Tones.
8.4.1: Trouble Tones
The Trouble Tones option allows you to enable or disable audible trouble annunciation.
To program the Trouble Tones option:
1. From the Programming menu, select Tones, Trouble Tones [936].
2. Select Enabled or Disabled.
8.4.2: Telephone Trouble Tones
Most trouble tones are not sounded between 10:00pm and 7:00am so as not to disturb
the user late at night. Telephone trouble, however, may be an attempt to sabotage the
system by cutting the telephone wires. For this reason, you can program telephone
trouble tones to sound at all times.
To program the Telephone Trouble Tones option:
1. From the Programming menu, select Tones, Tel. Trb. Tones [937].
2. Select Immediate or Delayed.
,
It is not necessary to program this option if the Trouble Tones option (see above) is
programmed as disabled.
8.5: Tones Output
From firmware versions 2.11 and above, you can determine whether the tones sounded
when arming and disarming are sounded by the internal siren or the control panel’s builtin speaker.
To program the Tones Output option:
1. From the Programming menu, select Tones, Tones Output [938].
2. Select Internal Siren or Speaker.
-45-
Chapter Nine: System Options
As the name suggests, System Options are settings that affect the entire system. This
chapter offers explanations and programming instructions for each of these options.
9.1: Swinger Setting
A sensor defined as Swinger enabled can generate only a limited number of alarms
during a specific time period or during an arming period. The following options are
available:
•
One alarm per arming period
•
One alarm per hour
•
One alarm per day
•
One alarm per week
To program the Swinger setting:
1. From the Programming menu, select System Options, Swinger [9401].
2. Select a Swinger setting from the above list.
9.2: Code Lockout
The Code Lockout option locks the keypad for 30 minutes if five unsuccessful attempts
are made to enter the user code.
To program the Code Lockout setting:
1. From the Programming menu, select System Options, Code Lockout [9402].
2. Select Enable or Disable.
,
During the 30-minute lockout period, you can still arm and disarm the system using
keyfobs and smartkeys. If one key arming is enabled, you may still arm the system using
the wireless keypad.
9.3: Forced Arm
Forced arming enables you to arm the system when the system is not ready. This option
allows you to enable or disable Forced arming for the entire system. Additionally, you can
enable or disable Forced arming for each individual zone. For further information, see
section 7.6.5: Force Arm.
To program the Forced Arm setting:
1. From the Programming menu, select System Options, Forced Arm [9403].
2. Select Enable or Disable.
9.4: HA Control
The HA Control option allows you to enable or disable all Home Automation features for
the entire system.
To program the Home Automation setting:
1. From the Programming menu, select System Options, HA Control [9404].
2. Select Enable or Disable.
-46-
9.5: Panic Alarm
SOS Panic alarms generated from the front panel, keypads or keyfobs can be defined as
either audible or silent.
To program the Panic Alarm setting:
1. From the Programming menu, select System Options, Panic Alarm [9405].
2. Select Audible or Silent.
9.6: One-Key Arming
You can arm the system by pressing any of the three arming keys on the keypad. If OneKey Arming is enabled, the system does not prompt you for a user code.
To program the One-Key Arming setting:
1. From the Programming menu, select System Options, One-Key Arming [9406].
2. Select Enable or Disable.
9.7: Supplementary Entry Delay
The Supplementary Entry Delay is a pre-alarm feature that is employed in the event that
the system is not disarmed during the entry delay. When the entry delay expires, the
internal siren is sounded during an additional entry delay period. At the end of the
supplementary entry delay, the system generates a full alarm condition; the external
siren is sounded and the central station is notified.
To program the Supplementary Entry Delay setting:
1. From the Programming menu, select System Options, Supp. Entry Delay
[9407].
2. Select Enable or Disable.
9.8: Entry Deviation
Entry Deviation is a pre-alarm feature employed in the event that a sensor defined with
the “Normal” zone type is opened during the entry delay. In this case, the internal siren is
sounded until the end of the entry delay period. Failure to disarm by the end of the entry
delay causes the system to generate an alarm.
To program the Entry Deviation setting:
1. From the Programming menu, select System Options, Entry Deviation [9408].
2. Select Enable or Disable.
-47-
9.9: AC Loss Delay
The AC Loss Delay is the amount of time that has to elapse before an AC Loss report is
sent to the central station. If AC power is restored before the event message is sent, the
event message is cancelled and will not be sent. You can program an AC Loss Delay to
be between 1 and 255 minutes after the system first senses the AC loss condition.
Alternatively you can program a random AC Loss Delay.
The AC Restore message is also sent using the same method described above. AC
Restore is reported only if the AC Loss report was sent.
To program the AC Loss Delay:
1. From the Programming menu, select System Options, AC Loss Delay [9409].
2. Enter a delay time (001-255 minutes) or enter 000 if you require the system to
choose a random AC Loss Delay.
3. Press when the desired setting is displayed.
9.9.1: Random AC Loss Delay
In the event of AC loss, an event message is sent to the central station between 15 and
30 minutes after the AC loss condition is sensed. The system chooses this delay at
random in order to prevent the central station being inundated by simultaneous AC Loss
reports in the event of a regional power cut.
9.10: Arm Status Display
The Arm Status Display includes the current arm status and any trouble conditions that
may exist within the system. You can program the system to display this information at all
times or only for two minutes after arming or disarming the system.
To program the Arm Status Display options:
1. From the Programming menu, select System Options, Arm Status Display
[9410].
2. Select Always or Display 2 Min.
9.11: Banner
The Banner is the 16-character text that you can program to appear on the top row of the
LCD display. This text replaces the arm status if it is programmed to display for two
minutes only – see 9.10: Arm Status Display.
To edit the Banner text:
1. From the Programming menu, select System Options, Banner [9411].
2. Edit the Banner text using the alphanumeric keypad.
3. Press when you have finished editing.
,
The system never displays the Banner text if the Arm Status Display option is
programmed as Always.
-48-
9.12: PGM Output
The PGM is a programmable output that is triggered according to specific system status
conditions.
9.12.1: Output Trigger
The Output Trigger option determines the conditions that activate and deactivate the
PGM output.
To program the Output Trigger:
1. From the Programming menu, select System Options, PGM Options, Output
Trigger [94121].
2. Select an Output Trigger option from the following table.
Trigger Option
PGM Not Used
Full Arm
Perimeter Arm
Part Arm
Arm Status
Power Trouble
Tel. Line Trouble
System Trouble
Medical
Burglary
Fire Alarm
Zone Status*
Entry/Exit
Internal Bell
Activated by…
The PGM output is disabled
System “Full” armed
System “Perimeter” armed
System “Part” armed
Any arming method
AC Loss or Low Battery
conditions
Telephone line supervision
trouble
System trouble condition
Medical alarm
Burglary alarm
Fire alarm
Open zones (steady)
Bypassed zones (pulsing)
Entry/Exit delay follower
Internal siren follower
Deactivated by…
System disarmed
or
PGM Cut-off
AC restore or Battery restore
Telephone line restore
System trouble restore
Any arming method,
system disarmed
or PGM Cut-off
All zones closed and no zones
bypassed
Table 9.1: PGM Output Trigger Options
* Functions only when the system is disarmed.
,
For certain trigger options, deactivation may be determined by the PGM Cut-off (see
9.12.4: PGM Cut-off). If the PGM Cut-off is programmed as 000 (continuous activation),
the PGM output shall remain activated until it is toggled by the relevant change in system
status.
9.12.2: Output Type
The Output Type option determines whether the PGM output produces a steady or
pulsed output.
To program the Output Type:
1. From the Programming menu, select System Options, PGM Options, Output
Trigger [94122].
2. Select Steady or Pulsed.
,
The Zone Status and Internal Bell trigger options have a fixed Output Type; there is no
need to program an Output Type for these options.
-49-
9.12.3: Polarity
You can determine the polarity of the PGM output from the following two options:
•
•
Active High: The output is normally off and is switched on when activated.
Active Low: The output is normally on and is switched off when activated.
To program the Output Type:
1. From the Programming menu, select System Options, PGM Options, Polarity
[94123].
2. Select Active High or Active Low.
9.12.4: PGM Cut-off
The PGM Cut-off is the duration for which the PGM is activated. Certain Output Trigger
types, are deactivated after the PGM Cut-off time has expired– see Table 9.1: PGM
Output Trigger Options. For those Output Trigger types that are not affected by the PGM
Cut-off, there is no need to program this option.
To program the PGM Cut-off time:
1. From the Programming menu, select System Options, PGM Options, PGM
Cut-off [94124].
2. Enter a PGM Cut-off time (001-255 seconds or 000 for continuous activation).
3. Press when the desired setting is displayed.
9.13: Guard Code (for future use)
The Guard Code is a future option that is not available in the current firmware. The
default setting for this option is disabled. Electronics Line 3000 recommend that you do
not change this setting.
9.14: Time/Date Format
This option determines the format in which the time and date are displayed in the user
interface. The following options are available:
•
•
•
•
DD/MM/YY, 24Hr
DD/MM/YY, 12Hr
MM/DD/YY, 24Hr
MM/DD/YY, 12Hr
To program the Time/Date Format:
1. From the Programming menu, select System Options, Time Format [9414].
2. Select the required format from the options available.
9.15: “No Arm” Indication
The “No Arm” indication is a feature designed to inform the central station that the
system has not been armed for a specified period of time.
To define the “No Arm” indication interval.
1. From the Programming menu, select System Options, No Arm Ind. [9415].
2. Select the required interval from the options available (1-4 weeks).
-50-
9.16: Supervised Arm
The Supervised Arm option is a feature designed to supervise intrusion sensor activity
before you arm the system.
If the system has not received a transmission from a sensor during the interval defined
for this option, all arming methods that include that sensor shall not be available.
Medical, Panic, Fire and Environmental zones are not included in this supervision and do
not affect the system’s ability to arm.
Press
to check which sensor is causing the “System Not Ready” condition.
To make the required arming method available, activate the sensor. It is important to
remember that the PIR sensors have a four-minute delay between transmissions.
If activating the sensor does not help, there may be a problem with the sensor. You can
bypass the faulty sensor’s zone to allow system arming until the problem is remedied.
,
Zone bypassing is valid for one arming period only. All bypassed zones are automatically
unbypassed when the system is disarmed.
To program the Supervised Arm interval:
1. From the Programming menu, select System Options, Superv. Arm [9416].
2. Enter a Supervised Arm interval (001-255 minutes or 000 to disable the
Supervised Arm option).
3. Press when the desired setting is displayed.
,
Do not program a Supervised Arm interval that is less than the sensor’s supervision time.
-51-
Chapter Ten: Communications
This section explains how to determine the way the control panel communicates via the
GSM and PSTN modules.
10.1: Accounts
The control panel supports three customer accounts. Each account has its own
telephone number and communications options. An explanation of each of these options
is included in this section.
10.1.1: Telephone Number
To edit an account’s telephone number:
1. From the Programming menu, select Communications, Accounts [951].
2. Select an account.
3. From the account’s sub-menu, select Telephone # [#1].
4. Enter up to 16 digits. Use the key to enter “*”, “,” (pause), “T” (switch to DTMF
tone dialing), “P” (switch to pulse dialing) or “+” (international code). Use the
key to delete one character at a time.
5. Press when you have finished editing.
10.1.2: Account Number
To edit an account number:
1. From the Programming menu, select Communications, Accounts [951].
2. Select an account.
3. From the account’s sub-menu, select Account # [#2].
4. Enter up to eight digits. Enter leading zeros for account numbers of less than
eight digits. Use the key to enter hexadecimal digits.
,
5.
If the programmed protocol is Contact ID, “A” is not a valid entry in the account number.
Press when you have finished editing.
10.1.3: Protocol
To program an account’s communication protocol:
1. From the Programming menu, select Communications, Accounts [951].
2. Select an account.
3. From the account’s sub-menu, select Protocol [#3].
4. Select a protocol from the options available.
,
Account number 3 is designed for use with the Follow me feature. It is the only telephone
number that can be programmed by the user.
10.1.4: Communication Interface
For each account, you can choose whether the system employs cellular or PSTN
communication.
To program an account’s communication interface:
1. From the Programming menu, select Communications, Accounts [951].
2. Select an account.
3. From the account’s sub-menu, select Interface [#4].
4. Select either GSM or PSTN.
-52-
10.1.5: Call Attempts
The Call Attempts option determines the number of times the system tries to call a
telephone number before moving on to the next number in sequence.
To program the number of call attempts for an account:
1. From the Programming menu, select Communications, Accounts [951].
2. Select an account.
3. From the account’s sub-menu, select Call Attempts [#5].
4. Enter a value between 01 and 15.
5. Press when the desired setting is displayed.
10.1.6: Two-Way Audio
The Two-Way audio option determines whether Two-Way Audio is enabled for the
account. For further information, see section 5.2.2: TWA Alarm Reporting.
To program the number of call attempts for an account:
1. From the Programming menu, select Communications, Accounts [951].
2. Select an account.
3. From the account’s sub-menu, select TWA [#6].
4. Select Enable or Disable.
10.2: General Account Options
The options included in this section concern event reporting for all three accounts.
10.2.1: Call Continue
When reporting an event, the system attempts to call Telephone #1. If the system fails in
its attempt to report the event, it dials Telephone #2 then Telephone #3, respectively. If
the Call Continue feature is active, the control panel sends a duplicate report to the
accounts that are selected. For example, using this feature, the system can send an
alarm report to the central station then notify the user by sending an SMS message to
their mobile phone.
To program the Call Continue option:
1. From the Programming menu, select Communications, Accounts, Call Continue
[9514]; the current Call Continue setting is displayed.
Press…
1
2
3
To…
Toggle Account #1 in the Call Continue sequence.
Toggle Account #2 in the Call Continue sequence.
Toggle Account #3 in the Call Continue sequence.
Table 10.1: Call Continue Options
2.
3.
Use keys 1, 2 and 3 to toggle the account numbers.
Press when the desired setting is displayed.
-53-
10.2.2: Report Cycles
The system’s attempts to report events are organized in cycles. A report cycle is a set of
call attempts. If the system does not succeed in sending a report to any of the telephone
numbers, it tries to dial the entire report cycle again until it sends a successful report.
You can determine the number of times the system attempts to dial this sequence by
programming the Report Cycle option.
To program the number of Report Cycles:
1. From the Programming menu, select Communications, Accounts, Report
Cycles [9515].
2. Enter a value between 01 and 03.
3. Press when the desired setting is displayed.
In the example illustrated in Figure 10.1, Account 1 is programmed with 2 call attempts,
Account 2 is programmed with 3 call attempts and the number of report cycles
programmed is 3.
Figure 10.1: Typical Report Cycle Sequence
10.3: Remote Programming
Electronics Line 3000’s Remote Programmer (RP) software enables you to operate and
program the system from a PC either on-site or from a remote location. The software
provides a comprehensive interface to the infinite control panel designed to facilitate
programming.
You can connect to the panel from a PC using one of three methods:
•
•
•
Direct Call: The RP calls the site, the system picks up and RP communication is
established.
Callback: The RP calls the site, the system picks up then hangs up. The system
then calls the Callback telephone number to establish a connection.
Serial Connection: The RP connects directly via the Main board’s 9-pin serial
port (this method requires that you install the optional Serial Interface board).
-54-
The following programming options relate to the method in which the Remote
Programmer software connects with the system.
10.3.1: Callback Telephone Number
RP Callback is a security feature that helps ensure that remote programming is only
performed by authorized personnel. When the Remote Programmer contacts the panel,
the panel hangs up and calls the Callback telephone number.
To edit the Callback telephone number:
1. From the Programming menu, select Communications, Remote Prog.,
Callback # [9521].
2. Enter up to 16 digits. Use the key to enter “*”, “,” (pause), “T” (switch to DTMF
tone dialing), “P” (switch to pulse dialing) or “+” (international code). Use the
key to delete one character at a time.
3. Press when you have finished editing.
,
If there is no Callback telephone number programmed, RP Callback is disabled and the
system connects to the Remote Programmer software using the “direct call” method.
10.3.2: RP Passcode
The RP passcode is a six-digit code that grants access to remote programming. When
establishing an RP connection, the passcode programmed in the RP customer file on the PC
must be identical to the system’s RP passcode.
To edit the RP passcode:
1. From the Programming menu, select Communications, Remote Prog.,
RP Passcode [9522].
2. Enter up to six digits.
3. Press when you have finished editing.
10.3.3: RP Communication Interface
The infinite can employ either cellular or PSTN communication during remote
programming.
For PSTN communication, the RP uses a double call method so that the line can be
shared with regular telephone handsets, an answering machine or fax. The Cellular
Communications Module has its own individual telephone number for data transfer and
therefore, the double call method is not needed. In this case, the RP calls the control
panel directly.
To program the RP communication interface:
1. From the Programming menu, select Communications, Remote Prog.,
RP Interface [9523].
2. Select either GSM or PSTN.
-55-
10.3.4: RP Access Options
Options are available to enable, disable or limit access to remote programming.
To program RP Access Options:
1. From the Programming menu, select Communications, Remote Prog.,
RP Access [9524].
2. Select an RP access option from the following table.
Access option
Always
During Disarm
Disable
User Initiated
Description
Up/downloading is always possible.
The system must be disarmed in order to establish a connection.
Up/downloading is disabled.
The user must perform Enable RP from the Service menu in order to
establish a connection – see 4.7.10: Enable Remote Programming.
Table 10.2: RP Access Options
10.4: Service Call
The Service Call feature is designed to enable the user to call the monitoring service at
the push of a button. When the user presses and holds down the Service Call button (0)
for a few seconds, a two-way audio connection is established with the central station.
10.4.1: Service Call Telephone Number
To edit the Service Call telephone number:
1. From the Programming menu, select Communications, Service Call, Phone
Number [9531].
2. Enter up to 16 digits. Use the key to enter “*”, “,” (pause), “T” (switch to DTMF
tone dialing), “P” (switch to pulse dialing) or “+” (international code). Use the
key to delete one character at a time.
3. Press when you have finished editing.
10.4.2: Service Call Interface
For the Service Call feature, you can choose whether the system employs cellular or
PSTN communication.
To program the Service Call interface:
1. From the Programming menu, select Communications, Service Call, Interface
[9532].
2. Select either GSM or PSTN.
10.5: SMS Center
To edit the SMS Center telephone number:
1. From the Programming menu, select Communications, SMS Center [954].
2. Enter up to 16 digits. Use the key to enter “*”, “,” (pause), “T” (switch to DTMF
tone dialing), “P” (switch to pulse dialing) or “+” (international code). Use the
key to delete one character at a time.
3. Press when you have finished editing.
-56-
10.6: Communications Options
10.6.1: Line Monitor
The Line Monitor feature monitors both the PSTN telephone line and the GSM network. If
a problem is detected with either of these, a Media Loss event is registered in the log.
To program the Line Monitor setting:
1. From the Programming menu, select Communications, Comm. Options, Line
Monitor [9551].
2. Select Enable or Disable.
10.6.2: Periodic Test Interval
The Periodic Test is a test transmission the system sends to notify the central station that
its reporting capability is fully functional.
Two options are available for the Periodic Test:
•
•
You can program the system to send a Periodic Test message according to a
chosen time interval. This time interval can be between 1 and 254 hours
(approximately 10 days).
The system sends a test every four weeks and calculates automatically the time
the Periodic Test is sent according to the last four digits of the account number.
This feature ensures that the central station is not inundated by test reports at
any given time.
To program the Periodic Test Interval:
1. From the Programming menu, select Communications, Comm. Options, Test
Interval [9552].
2. Enter the test interval (001-254 hours) or 255 for an automatically calculated
test interval.
3. Press when the desired setting is displayed.
To disable the Periodic Test:
•
Program the Periodic Test Interval as 000.
10.6.3: First Test
If the Periodic Test Interval is programmed as 001-254 hours, you must also program the
time that the first Periodic Test is sent.
To program the First Test Time:
1. From the Programming menu, select Communications, Comm. Options, First
Test [9553].
2. Enter a time (HH:MM).
3. Press when the desired setting is displayed.
-57-
10.6.4: Call Timeout
The Call Timeout is the amount of time the system waits for the first acknowledgement
(ACK1) from the central station when reporting using the PSTN module. If ACK1 is not
received during this time, the system regards the call as a failed dialing attempt.
To program the Call Timeout:
1. From the Programming menu, select Communications, Comm. Options, Call
Timeout [9554].
2. Enter a time (001-255 seconds).
3. Press when the desired setting is displayed.
10.6.5: ACK. Timeout
The ACK Timeout is the amount of time the system waits for the second
acknowledgement (ACK2) from the central station when reporting using the PSTN
module. If ACK2 is not received during this time, the system regards the call as a failed
dialing attempt.
To program the ACK Timeout:
1. From the Programming menu, select Communications, Comm. Options, ACK
Timeout [9555].
2. Enter a time (001-255 seconds).
3. Press when the desired setting is displayed.
10.6.7: PSTN Country
In order to meet the requirements of local telecommunications authorities, default
telephone line parameters have been chosen for a number of different countries.
To program the PSTN Country:
1. From the Programming menu, select Communications, Comm. Options, PSTN
Country [9556].
2. Select your country from the options available.
,
Electronics Line 3000 offers custom telephone line parameter settings for countries that
do not appear in the list of pre-defined options. If your country does not appear among the
available options, select the option Custom Settings.
10.6.8: Dial Tone Wait
This option determines whether the system dials only when the dial tone is present or if
the dialing is initiated regardless of the dial tone.
To program the Dial Tone Wait option:
1. From the Programming menu, select Communications, Comm. Options, Dial
Tone Wait [9557].
2. Select Enable or Disable.
-58-
10.7: Two-Way Audio Options
The infinite control panel offers a number of Two-Way Audio features that can be used in
various applications. This section explains the programming options that control the
mode in which these features function. For further information on Two-Way Audio, see
Chapter Five: Two-Way Audio.
10.7.1: Incoming Two-Way Audio
This option determines whether the user/central station operator can establish Two-Way
Audio communication with the control panel.
To program the Incoming Two-Way Audio setting:
1. From the Programming menu, select Communications, Comm. Options,
Incoming TWA [95581].
2. Select Enable or Disable.
10.7.2: Two-Way Audio Timeout
The Two-Way Audio Timeout is the duration of a Two-Way Audio call. When the time out
expires, the system automatically disconnects unless the call is manually extended by
the operator.
To program the Two-Way Audio Timeout:
1. From the Programming menu, select Communications, Comm. Options, TWA
Timeout [95582].
2. Enter a time (001-255 seconds).
3. Press when the desired setting is displayed.
10.7.3: Microphone/Speaker Options
In addition to the built-in microphone and speaker, the infinite control panel supports an
external microphone speaker unit. The Microphone/Speaker options allow you to choose
which microphone and speaker shall function during Two-Way Audio communication.
You can choose one mic./speaker (internal or external) to function exclusively or both
may function simultaneously.
To program the Microphone/Speaker options:
1. From the Programming menu, select Communications, Comm. Options,
Mic./Speaker [95583].
2. Select one of the available options.
10.7.4: TWA Mode
The Two-Way audio features offer a choice of two operation modes:
•
Duplex – both parties may speak at once just like a regular telephone.
•
Simplex – one party may speak while the other party listens.
To program the TWA mode option:
1. From the Programming menu, select Communications, Comm. Options, TwoWay Audio, TWA Mode [95584].
2. Select Duplex or Simplex.
-59-
10.8: GSM RX Report
The GSM RX Report is a feature that periodically reads the GSM signal strength of the
Cellular Communications module – see 4.7.8: GSM Signal Strength.
This reading occurs at the times programmed for the Periodic Test – see 10.6.2: Periodic
Test Interval & 10.6.3: First Test. This means that each time the periodic test is sent, the
system also sends a GSM signal strength report to the central station. The system also
enters the GSM signal strength in the event log.
,
If the Periodic Test is disabled, the GSM RX Report feature will not function.
The GSM RX report belongs to the Peripherals event group – see 10.9: Event Options. If
this event group is disabled, the GSM signal strength is still recorded in the event log.
To program the GSM RX Report option:
1. From the Programming menu, select Communications, Comm. Options, GSM
RX Report [9559].
2. Select Enable or Disable.
10.9: Event Options
System events are divided into a number of different event groups. This division allows
you to enable or disable reporting or Two-Way Audio for a specific group of events.
The different event groups are as follows:
•
•
•
•
•
•
•
•
Burglary [#1]
Fire [#2]
Open/Close (arm/disarm) [#3]
Service [#4]
Power [#5]
Peripherals [#6]
RF Jamming [#7]
Medical [#8]
10.9.1: Event Reporting
You can enable or disable event reporting per Event Group. This allows you to filter the
type of events that are reported to the central station.
To enable/disable reporting for an event group:
1. From the Programming menu, select Communications, Event Options [956].
2. Select an Event Group.
3. From the event group’s sub-menu, select Report [#1].
4. Select Enable or Disable.
10.9.2: Restore Reporting
For each event group, you can determine whether restore messages shall be sent.
To enable/disable restore reporting for an event group.
1. From the Programming menu, select Communications, Event Options [956].
2. Select an event group.
3. From the event group’s sub-menu, select Report Restore [#2].
4. Select Enable or Disable.
-60-
10.9.3: Two-Way Audio
For Burglary, Fire and Medical event groups, there is an additional option that enables
Two-Way Audio for that event group – see 5.2.2: TWA Alarm Reporting.
To enable/disable Two-Way Audio for an event group:
1. From the Programming menu, select Communications, Event Options [956].
2. Select an Event Group (Burglary, Fire or Medical).
3. Select TWA [#3].
4. Select Enable or Disable.
-61-
Chapter Eleven: Home Automation Programming
This chapter explains the programmable options for the system’s home automation
features. The Home Automation module is an add-on optional extra that you can install
inside the panel’s plastic housing.
11.1: X10 Overview
The control panel’s home automation feature employs the X10 protocol and this enables
compatibility with a wide variety of readily available home automation products.
Before you can start programming the system’s Home Automation features, you should
be familiar with the basic concept behind X10 automation.
X10 is a protocol that enables you to send commands and other data over regular
existing power lines. This means that, using an X10 transmitter (the panel’s Home
Automation module), you can send On/Off commands to X10 receivers (lamp and
appliance modules) that are plugged into electricity outlets around the home. From here
on, we shall refer to these X10 receivers as “HA units”.
Each HA unit has two codes that are used for identification. These codes are known as
the House code and the Unit code and are usually defined by adjusting the dials that
appear on the X10 unit. In Figure 11.1, the HA unit is set to House A, Unit 3.
Figure 11.1: HA Unit Dials
The control panel supports sixteen HA units on one House code. To ensure that the
Home Automation features function correctly, you must abide by the following guidelines.
•
•
The House code must be the same on each HA unit.
The House code on the HA units must be identical to the House code
programmed in the panel’s memory – see section 11.3: House Code.
11.2: HA Units
The following sections explain the programming options available for HA units.
11.2.1: Scheduling
Scheduling allows you to program the panel to send On/Off commands to an HA unit at
specific times. The Scheduling section of Home Automation programming is identical to
that described in Chapter Six: Home Automation Control. For further information on
programming the On Time, Off Time and Schedule for each HA unit, see section 6.4:
Scheduling.
-62-
11.2.2: On by Zone
The On by Zone feature allows you to choose two zones that activate the HA unit when
triggered. When either one of these zones is triggered, the system sends an On
command to the HA unit according to the unit’s programmed Pulse Time – see 11.2.7:
Pulse Time. For example, you have a magnetic contact installed above the front door.
When the door is opened, the hall light is lit.
To select the sensors that activate an HA unit:
1. From the Programming menu, select HA Programming, HA Units [961].
2. Select an HA unit (01-16).
3. From the HA unit’s sub-menu, select On by Zone [#4].
4. Enter up to two zone numbers.
5. Press when the desired setting is displayed.
11.2.3: On by Arm
The On by Arm feature activates the HA unit when the system is armed using any of the
arming methods. The amount of time the HA unit is activated is determined by the Pulse
Time – see 11.2.7: Pulse Time. If the Pulse Time is programmed as “Toggle”, disarming
the system switches the HA unit off.
To program the On by Arm feature:
1. From the Programming menu, select HA Programming, HA Units [961].
2. Select an HA unit (01-16).
3. From the HA unit’s sub-menu, select On by Arm [#5].
4. Select Enable or Disable.
11.2.4: Keyfob Control
Each EL-2614 keyfob, offers control of up to two individual HA units. This programming
option allows you to enable or disable this feature per HA unit.
To program the keyfob control option for an HA unit:
1. From the Programming menu, select HA Programming, HA Units [961].
2. Select an HA unit (01-16).
3. From the HA unit’s sub-menu, select KF Control [#6].
4. Select Enable or Disable.
11.2.5: SMS Control
Via SMS, you can send commands to the system in order to control various HA units.
This option allows you to enable or disable this feature for each HA unit.
To program the SMS control option for an HA unit:
1. From the Programming menu, select HA Programming, HA Units [961].
2. Select an HA unit (01-16).
3. From the HA unit’s sub-menu, select SMS Control [#7].
4. Select Enable or Disable.
-63-
11.2.6: Randomize
When the system is fully armed between the hours 9:00pm and 6:00am, the Randomize
feature turns HA units on and off at random. This gives the impression that the house is
occupied and acts as a deterrent against potential intruders.
To program an HA unit to be included in the Randomize feature:
1. From the Programming menu, select HA Programming, HA Units [961].
2. Select an HA unit (01-16).
3. From the HA unit’s sub-menu, select Randomize [#8].
4. Select Enable or Disable.
11.2.7: Pulse Time
The Pulse Time determines the manner in which an HA unit responds to the On
command. You can program each HA unit switch on momentarily. This means that, on
receiving the On command, the unit will be switched on for a programmed amount of time.
For example, you can program the hall light to switch on for 1 minute and automatically
switch itself off. Alternatively, the HA unit can be programmed to toggle on and off.
To program the Pulse Time for an HA unit:
1. From the Programming menu, select HA Programming, HA Units [961].
2. Select an HA unit (01-16).
3. From the HA unit’s sub-menu, select Pulse Time [#9].
4. Select 5 sec, 30 sec, 1 min, 2 min or Toggle.
11.2.8: Descriptor
You can assign a 16-character descriptor for each HA unit. These descriptors help the
user to identify the various HA units installed around the home.
To edit an HA unit descriptor:
1. From the Programming menu, select HA Programming, HA Units [961].
2. Select an HA unit (01-16).
3. From the HA unit’s sub-menu, select Descriptor [#0].
4. Edit the descriptor using the alphanumeric keypad.
5. Press when you have finished editing.
11.3: House Code
The House code is part of the identification code of each HA unit. For the Home
Automation features to function correctly, the House code on each HA unit must be
identical to the House code programmed in the system’s memory.
To program the system House code:
1. From the Programming menu, select HA Programming, House Code [962].
2. Select a House code from the options available (A-P).
11.4: SMS Confirmation
After an SMS command is executed by the system, a confirmation message is returned
to the sender’s mobile phone. You can enable or disable this feature using this option.
To enable/disable SMS confirmation:
1. From the Programming menu, select HA Programming, SMS Confirm. [963].
2. Select Enable or Disable.
-64-
Chapter Twelve: System Initialization
The Initialization menu offers a number of options that enable you to reset the system.
This menu is particularly useful when re-installing a panel at a new site. The Initialization
function clears the entire system. This restores programming defaults, clears the log,
user codes and the transmitter register. Options are also available that enable you to
clear a specific section of the system’s memory separately.
12.1: Initialization
The Initialization function clears the entire system and resets factory defaults.
To initialize the control panel:
1. From the Programming menu, select Initialize, Init All [971]; the system
prompts you for confirmation.
2. Press to confirm; factory programming defaults are restored, the event log is
cleared, user codes and wireless transmitters are deleted.
12.2: Default Program Restore
Loading the system’s default program enables you to restore the factory-set
programming defaults.
To load the default program:
1. From the Programming menu, select Initialize, Load Defaults [972]; the system
prompts you for confirmation.
2. Press to confirm; factory programming defaults are restored.
12.3: Clear User Codes
Clear User Codes deletes all programmed user codes and restores the default Master
and Installer codes.
To clear user codes:
1. From the Programming menu, select Initialize, Clear Users [973]; the system
prompts you for confirmation.
2. Press to confirm; all user codes are deleted and default codes are restored.
12.4: Clear Wireless Transmitters
The Clear Wireless Transmitters function enables you to delete all registered transmitters
at once.
To clear the transmitter register:
1. From the Programming menu, select Initialize, Clear Wireless [974]; the system
prompts you for confirmation.
2. Press to confirm; the transmitter register is cleared.
-65-
12.5: Find Modules
There are three optional modules that you can connect to the system bus. These are the
PSTN module, the GSM module and the Home Automation module. The Find Modules
function runs a diagnostic test that identifies the modules that are connected to the
system bus. With this information, the system knows which add-on modules should be
present, enabling supervision for those modules.
To run the Find Modules test:
1. From the Programming menu, select Initialize, find Modules [975]; the system
prompts you for confirmation.
2. Press to confirm; the system begins to search for the connected modules. At
the end of the search, the modules that are present are displayed and the
system asks if you want to save the displayed list.
3. Press ; the list is saved.
,
If a connected module is not included in the list, check the wiring connections and run this
test again.
-66-
Appendix A: Menu Structure
Legend:
Installer code required
Master code required
-67-
-68-
*
* Firmware versions 2.11 and above.
-69-
-70-
-71-
Appendix B: Transmitter Installation
PIR Sensors (EL-2600/EL-2600PI/EL-2645/EL-2645PI)
The EL-2600, EL-2600PI, EL-2645 and EL-2645PI are intelligent wireless PIR sensors for
use with the infinite system. All of these sensors implement a feature to combat the problem
of multiple transmissions, which drastically reduce the life of the batteries. After each
transmission, there is a four-minute delay during which further transmissions will not be sent.
The EL-2600PI and EL-2645PI are designed for installations prone to nuisance alarms
caused by pets or small animals.
Mounting
Hole
Mounting
Hole
LED
Jumper
LED
Indicator
LED
Indicator
Battery
Holder
Battery
Holder
Easy
Lock
Mode
Jumper
Tamper
Switch
Pulse Count
Jumper
Antenna
Vertical
Adjustment
Scale
Easy
Lock
Tamper
Switch
Mode
Jumper
DIPSwitch
Antenna
Vertical
Adjustment
Scale
Pyro
Sensor
Pyro
Sensor
Figure B.1: PIR Sensors with Cover Removed – EL-2600/EL-2600PI (left) and EL-2645/EL-2645PI (right)
Considerations Before Installation
•
•
•
•
Select a location from which the pattern of the detector is most likely to be
crossed by a burglar, should there be a break in.
Do not place bulky objects in front of the
Lens
Mounting Height
detector.
Standard
2.2m (6.6’)
Avoid a location which comes in direct
Long Range
2m (6.5’)
contact with radiators, heating/cooling
Curtain
1m (3.25’)
ducts, mirrors and air conditioners.
EL-2600PI
2m (6.5’)
EL-2645PI
2m (6.5’)
Select an appropriate installation height
Table B.1: Recommended Mounting Height
from Table B1.
Pet Immunity Guidelines (EL-2600PI/EL-2645PI)
It is expected that the EL-2600PI and EL-2645PI will eliminate false alarms caused by:
•
•
,
•
•
Animals up to 22kg (EL-2600PI)
Animals up to 45kg (EL-2645PI)
Several small rodents
Random flying birds.
The weight of the animal should only be used as a guide, other factors such as the length
and color of fur also affect the level of immunity.
-72-
For maximum pet immunity the following guidelines are recommended:
•
Mount the center of the unit at a height of 2m with the PCB vertical setting at -4.
•
Set the pulse counter to 2.
•
Do not aim the detector at stairways that can be climbed by an animal.
•
Avoid a location where an animal can come within 1.8m of the detector by
climbing on furniture, boxes or other objects.
Installation Procedure
To install PIR sensors:
1. Open the housing by removing the front cover. To do so, insert a screwdriver in
the release slot (located at the bottom of the detector between the front and
back cover). Turn the screwdriver 90º to release the cover.
2. Remove the PCB by turning counter-clockwise and removing the Easy Lock –
do not touch the face of the pyro sensor!
3. Apply battery power by removing the isolator that separates the battery from the
contacts on the battery holder.
4. Place the Mode jumper over pins 2 & 3 (Radio Mode); the LED flashes.
,
5.
6.
7.
8.
9.
10.
11.
Install the Mode jumper only after applying battery power.
From the Programming menu, select Devices, Zones [911].
Select the zone to which you want to register the transmitter; the system initiates
Registration mode. When Save? appears on infinite’s LCD display, press .
Remove the Mode jumper and place it over one pin for storage.
Choose an appropriate mounting height from Table B.1 and test the transmitter
from the exact mounting position before permanently mounting the unit.
Knock out the mounting holes and attach the base to the wall.
Mount the PCB at the required vertical adjustment and replace the PCB screw.
Write the number of the zone on the sticker provided. Affix the sticker inside the
front cover for future reference and replace the front cover.
Warm-Up Time
The detector will need to warm up for the first
90 seconds after applying power.
Pulse Counter
The pulse counter determines the amount of
beams that need to be crossed before the
detector will generate an alarm. To set the
pulse counter, refer to tables B.2 and B.3.
Adaptive Pulse Count (EL-2645/EL-2645PI)
Using the Adaptive pulse count feature, the
detector chooses between 1 or 2 pulses
based on its analysis of the received signal.
Jumper Position
Pins 1&2
Pins 2&3
Jumper Removed
Pulse Count
1
2
3
Table B.2: Pulse Count Jumper (EL-2600/EL-2600PI)
Switch 2
OFF
ON
ON
OFF
Switch 3
OFF
OFF
ON
ON
Pulse Count
1
2
3
Adaptive
Table B.3: Pulse Count Setting (EL-2645/EL-2645PI)
Vertical Adjustment
To position the PCB, turn the Easy Lock counter-clockwise and slide the PCB up or down
to the required setting using the vertical adjustment scale. The detector’s coverage area
is 14m x 14m (EL-2600/EL-2645) or 12m x 12m (EL-2600PI/EL-2645PI) when the PCB is
positioned at 0. Slide the PCB up towards the -8 position to decrease the coverage area
bringing the beams closer to the mounting wall.
-73-
Walk Test Mode
A walk test is performed in order to determine the lens coverage pattern of the detector –
see Figure B.2. Walk Test mode cancels the delay time between detections, enabling
you to perform an efficient walk test.
To perform a Walk Test.
1. Place the Mode jumper over pins 1 & 2.
2. Walk across the scope of the detector according to the detection pattern
selected.
3. Confirm that the LED activates and deactivates accordingly. Wait five seconds
after each detection before continuing the test.
4. After completing the walk test, remove the jumper and place it over one pin for
storage – see Mode Jumper Safeguard.
LED Indication
The LED indicator is lit twice every time a transmission is made. To enable or disable
LED indication, refer to Table B.4 below.
LED Indication
Disabed
Enabled
EL-2600/EL-2600PI
Remove LED Jumper
Install LED Jumper
EL-2645/EL-2645PI
DIP-Switch 1 OFF
DIP-Switch 1 ON
Table B.4: LED Indication Settings
,
The LED should only be disabled after successfully walk testing the detector.
Mode Jumper Safeguard
During normal operation, the Mode jumper should be placed over one pin for storage.
When the mode jumper is placed over two pins, the detector is either in Radio or Walk
Test Mode. As a precaution, these modes are limited to three minutes. After three
minutes have expired, the detector switches back to normal operation. If this happens,
you can reset a mode by removing and replacing the mode jumper.
Figure B.2: Lens Coverage Diagrams EL-2600/EL-2645 (left) and EL-2600PI/EL-2645PI (right)
-74-
Magnetic Contact (EL-2601)
The EL-2601 is a magnetic contact designed for installation on doors and windows.
Installation Procedure
To install magnetic contacts.
1. To open the housing, insert a small
screwdriver at the bottom of the unit
between the front and back cover and
twist the screwdriver to release the
cover.
2. Remove the divider separating the
battery from the contacts on the
battery holder. When you apply power
and the Tamper switch is open, the
EL-2601 enters Test mode during
which a transmission is sent every few
seconds. You can terminate Test
mode by closing the Tamper switch.
Test mode is automatically terminated
after approximately five minutes.
,
3.
4.
5.
6.
7.
8.
9.
10.
11.
Antenna
LED
Indicator
Battery
Holder
Tamper
Switch
Loop
Terminals
1cm max.
Operation
Mode
Location
of wiring
knockout
PCB
Release
Tab
Figure B.3: EL-2601 (cover off)
When handling the PCB, do not apply pressure on the antenna.
From the Programming menu, select Devices, Zones [911].
Select the zone to which you want to register the transmitter; the system
initiates Registration mode. When Save? appears on infinite’s LCD display,
press .
After registration, press the EL-2601’s tamper switch to terminate Test mode.
Before permanently mounting the unit, test the transmitter from the exact
mounting position.
To remove the PCB, press the PCB release tab and carefully lift the board and
slide the board away from the back cover.
The EL-2601 is able to operate in
Jumper Position Operation Mode
three modes: Magnetic Switch,
Pins 1&2
Universal Transmitter
Universal Transmitter or a combination
Pins 2&3
Magnetic Switch
of the two. If connecting a wired
Jumper
Magnetic Switch/
contact loop (N.C.), connect the
Removed
Universal Transmitter
terminal block as follows: 1 - Alarm; 2 Table B.2: Operation Mode Jumper
GND. For this purpose, a wiring
PCB
knockout is provided in the back cover.
Mount the back cover using two screws and replace the PCB.
Use ISO 7050 (ST3.5 x 22) or similar countersunk screws so
that the screw head will not touch the PCB – see Figure B.4.
To open the magnet’s housing, insert a small screwdriver into
one of the pry-off slots located at either end of the magnet’s
back cover and lift to separate from the front cover.
HOUSING
Mount the back cover of the magnet using two screws. Make
Figure B.4:
sure that the guideline on the magnet is correctly aligned with
Mounting
Screw Position
the guideline on the transmitter.
-75-
,
12.
13.
Do not install the magnet further than 1cm from the transmitter.
Test the transmitter, making certain that the LED is lit when opening the
door/window and again when closing.
Close the front covers of the transmitter and the magnet.
Universal Transmitter (EL-2602)
The EL-2602 is a universal transmitter that includes a single output for use in a wide
range of wireless applications.
Installation Procedure
Antenna
Battery
Holder
To install universal transmitters:
LED
1. To open the housing, insert a small
Indicator
screwdriver at the bottom of the unit
between the front and back cover
and twist the screwdriver to release
Tamper
the cover.
Switch
2. Remove the divider separating the
battery from the contacts on the
battery holder. When you apply power
Loop
and the Tamper switch is open, the
Terminals
EL-2602 enters Test mode during
PCB
Location
which a transmission is sent every few
Release
of wiring
seconds. You can terminate Test
Tab
knockout
mode by closing the Tamper switch.
Figure B.5: EL-2602 (cover off)
Test mode is automatically terminated
after approximately five minutes.
3. From the Programming menu, select Devices, Zones [911].
4. Select the zone to which you want to register the transmitter; the system initiates
Registration mode. When Save? appears on infinite’s LCD display, press .
5. After registration, press the EL-2602’s tamper switch to terminate Test mode.
6. Before permanently mounting the unit, test the transmitter from the exact
mounting position.
7. To remove the PCB, press the PCB release tab, carefully lift the board and slide
the board away from the back cover.
,
8.
9.
10.
11.
12.
13.
When handling the PCB, do not apply pressure on the antenna.
Knockout the wiring hole in the back cover.
Thread the wires through the wiring hole.
Mount the back cover to the wall using two screws and replace the PCB. Use
ISO 7050 (ST3.5 x 22) or similar countersunk screws so that the screw head will
not touch the PCB – see Figure B.4.
Connect the terminal block as follows: 1 - Alarm; 2 - GND.
Test the transmitter, making certain that the LED is lit during transmissions.
Close the front cover of the EL-2602.
-76-
Glassbreak Sensor (EL-2606)
The EL-2606 is an intelligent acoustic glassbreak sensor with an incorporated wireless
transmitter.
Mounting Considerations
The EL-2606 acoustic sensor is omnidirectional, providing 360º coverage.
The coverage is measured from the
sensor to the point on the glass
farthest from the sensor. The sensor
can be mounted as close as 1m from
Figure B.6: Acoustic Sensor Range Measurement
the glass.
(plate, tempered, laminated and wired glass)
Sensor range:
•
If mounting on the ceiling, the opposite wall or adjoining walls, the maximum
range is 6m for plate, tempered, laminated and wired glass.
•
For armor-coated glass, the maximum range is 3.65m.
Minimum recommended glass size:
•
0.3m x 0.6m
Glass thickness:
•
Plate: 2.4mm to 6.4mm
•
Tempered: 3.2mm to 6.4mm
•
Wired: 6.4mm
•
Laminated: 3.2mm to 6.4mm
For best detection:
•
The sensor must always be in direct line of sight of all windows to be protected.
•
If mounting on the wall, try to install the sensor directly opposite the protected
window. If this is not possible, adjoining side walls are also a good location.
•
If mounting on the ceiling, install the sensor 2-3m into the room.
•
Avoid installing in rooms with lined, insulating or sound deadening drapes.
•
Avoid installing in rooms with closed wooden window shutters inside.
•
Avoid installing in the corners of a room.
The EL-2606 is best suited to rooms with moderate noise.
,
The sensor may not consistently detect cracks in the glass, bullets which break through
the glass or glass breaking around corners and in other rooms. Glassbreak sensors
should always be backed up by interior protection.
For best false alarm immunity:
•
Locate the sensor at least 1.2m away from noise sources (televisions, speakers,
sinks, doors, etc.).
•
Avoid rooms smaller than 3m x 3m and rooms with multiple noise sources.
•
Do not use where white noise, such as air compressor noise, is present (a blast
of compressed air may cause a false alarm).
•
Do not define the zone as 24hr. It is recommended to register the EL-2606 to a
perimeter arming group that arms the perimeter doors and windows of the
premises.
•
Avoid humid rooms – the EL-2606 is not hermetically sealed. Excess moisture
can eventually cause a short and a false alarm.
-77-
Areas to avoid:
•
Glass airlocks and glass
vestibule areas
•
Noisy kitchens
•
Residential car garages
•
Small utility rooms
•
•
•
Stairwells
Small bathrooms
Other small acoustically live
rooms
For glass break protection in such applications, use shock sensors on the windows or
window frames connected to an EL-2602 universal transmitter.
Installation Procedure
Tamper
Switch
Battery
Holder
Terminal
Block
LED
Indicator
Antenna
Mounting
Knockout
Mounting
Knockout
Acoustic
Sensor
Figure B.7: EL-2606 (cover off)
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
Open the housing using a small flat-head screwdriver to separate the base from
the cover.
Remove the insulator separating the battery from the contacts on the battery
holder. When you apply power and the Tamper switch is open, the EL-2606
enters Test mode during which a transmission is sent every few seconds. You
can terminate Test mode by closing the Tamper switch. Test mode is
automatically terminated after approximately five minutes.
From the Programming menu, select Devices, Zones [911].
Select the zone to which you want to register the transmitter; the system initiates
Registration mode. When Save? appears on infinite’s LCD display, press .
After registration, press the EL-2606’s tamper switch to terminate Test mode.
Choose a suitable mounting location according to the guidelines in the previous
section.
Before permanently mounting the unit, test the acoustic sensor and the transmitter
from the exact mounting position. For further information on testing the acoustic
sensor, refer to the following section, Testing Procedures.
Knock out the required mounting holes on the back cover.
Mount the unit to the wall using the mounting screws provided.
Write the number of the zone on the sticker provided and affix the sticker inside
the front cover for future reference.
Close the front cover making sure that it snaps shut.
-78-
Testing Procedure
The Pattern Recognition Technology™ of the
EL-2606 ignores most of the sounds that
could cause a false alarm (including glassbreak testers). In order to test the EL-2606,
you must set the unit to Test mode. In Test
mode, processing of the upper and lower
frequencies is disabled. This means that the
EL-2606 is only listening for mid-range
frequencies reproduced by the glassbreak
tester. It’s these mid-range frequencies that
determine the sensor’s range.
,
Figure B.8: Testing the EL-2606
In Normal mode, the tester will not activate the sensor unless held directly over the sensor.
Test the sensor using the Electronics Line GBS7 or Sentrol 5709C hand-held tester.
1. If using the 5709C tester, set the tester to tempered glass. The 5709C tester has a
different setting for each type of glass. The tester should always be set for
tempered or laminated glass (either is correct and both have the same range)
unless the installer is certain that all the glass to be protected is plate glass.
2. Hold the tester speaker directly on top of the sensor and activate the tester; the
sensor generates an alarm and then enters test mode for one minute. When in
test mode, the LED on the sensor flashes continuously. You can extend the test
mode time by firing the tester at the sensor at least once a minute.
,
3.
4.
5.
6.
,
Each time the sensor generates an alarm, it also goes into Test mode for one minute.
Hold the tester near the surface of the glass and aim the tester at the EL-2606.
If drapes or blinds are present, test with the hand-held tester behind the closed
drapes or blinds.
Hold down the test button. When the LED on the sensor goes solid momentarily,
the glass is within detection range.
If the LED does not go solid, but simply continues blinking, re-position the sensor
closer to the protected windows and retest. This may require adding additional
sensors in order to achieve adequate coverage. It is very rare that the sensor will
not activate within its stated range of coverage. In this case check the battery in the
hand-held tester. A new tester battery is likely to restore the range.
Test mode automatically terminates approximately one minute after the last
activation of the hand-held tester.
Room acoustics can artificially extend the range of a glassbreak sensor. The specified range
of the EL-2606 has been established for worst-case conditions. While the sensor is likely
function at the extended range, it may miss a minimum output break or room acoustics may
be changed at some future time bringing sensor range back into normal 6m conditions. Do
not exceed the rated range of the sensor regardless of what the tester shows!
Hand Clap Test
The Hand Clap test enables you to test the EL-2606 while in Normal mode. This test
checks the sensors power supply, microphone and circuit board.
To perform a Hand Clap test
Clap your hands loudly under the sensor; the LED flashes twice but an alarm is not
generated.
-79-
Smoke Detector (EL-2603)
The EL-2603 is a brand-name smoke detector with an integrated Electronics Line 3000
transmitter.
Installation Procedure
The following procedure explains the installation of the EL-2603 wireless smoke detector
and its registration to the receiver. For further information regarding the smoke detector’s
location, test procedures, maintenance and specifications, refer to the manufacturer’s
installation instructions provided with this product.
To install smoke detectors:
1. Open the cover by lifting the opening Opening
Tab
tab while firmly holding the base with
your other hand.
2. Push the cover backwards to
separate the cover from the base.
3. Install a 9V battery into the detector’s
battery snap.
4. Insert the Test jumper; the EL-2603
enters Test mode and the LED
flashes every few seconds.
LED
5. From the Programming menu, select Indicator
Devices, Zones [911].
Test
6. Select the zone to which you want to Jumper
register the transmitter; the system
9V
initiates Registration mode. When Battery
Save? appears on infinite’s LCD
display, press .
Figure B.9: EL-2603 (cover open)
7. After registration, remove the Test
jumper and place it over one pin for
storage.
8. Before permanently mounting the unit, test the transmitter from the exact
mounting position.
9. Attach the mounting base to the ceiling using the screws provided.
10. Replace the cover onto its hinges and close the cover until it snaps together
with the base.
Keyfobs (EL-2611/EL-2614)
The EL-2611 and EL-2614 are keyfob transmitters that are supported by the infinite system.
Registration Procedure
To register keyfobs:
1. From the Programming menu, select Devices, Keyfobs [912].
2. Select the keyfob you want to register; the system initiates Registration mode.
3. Press a button, making sure that the keyfob’s LED lights up when the button is
pressed.
4. Press the same button again. When Save? appears on infinite’s LCD display,
press .
-80-
EL-2611
The EL-2611 is a one-button transmitter that generates a
Medical Emergency alarm when pressed. The transmitter is
water resistant and can be worn around the neck. Its large
button makes it ideal for elderly or sight-impaired users.
When the battery is low, the EL-2611’s LED flashes during
transmission and a Low Battery signal is sent to the receiver.
When either of these two indications are observed, replace the
unit.
Figure B.11: EL-2614
Figure B.10: EL-2611
EL-2614
The EL-2614 is a four-button keyfob transmitter that offers a
number of functions including arm, disarm and SOS Panic.
When the battery is low, the EL-2614’s LED flashes during
transmission and a Low Battery signal is sent to the receiver.
When either of these two indications are observed, replace
the batteries.
To replace the batteries:
1. Insert a small screwdriver into the pry-off slot – see
Figure B.12 Carefully twist the screwdriver to
separate the front and back of the casing.
2. Observing correct polarity, replace the batteries
(3V lithium, size: CR1225).
3. Close the casing making sure that the front and
back click shut.
Figure B.12: Opening
the EL-2614’s Casing
Wireless Keypads (EL-2620/EL-2640)
The EL-2620 and EL-2640 are one-way wireless
keypads primarily designed as additional arming
stations, including three arming keys that enable Full,
Part or Perimeter arming modes. Pressing the Full and
Perimeter buttons simultaneously generates an SOS
panic alarm. Additionally, the keypad may be used to
control Home Automation modules.
The EL-2620 also includes an additional Cancel key, ,
that clears the keypad in the event that a key is
pressed by mistake while entering a code, for example.
This key causes the keypad to disregard what was
previously entered enabling the user to start again.
Figure B.8: EL-2620
Figure B.13: EL-2620
Registration Procedure
To register wireless keypads:
1. From the Programming menu, select
Devices, Keypads [914].
2. Select the keypad you want to register; the
system initiates Registration mode.
-81-
Figure B.14: EL-2640
3.
4.
Press a button on the keypad making sure that a LED lights up when the button
is pressed.
Press the same button again. When Save? appears on infinite’s LCD display,
press .
Battery Replacement (EL-2620)
Every time a key is pressed, one of the battery status LEDs is lit. When the battery needs
to be replaced, the red Low Battery LED is lit.
To replace the battery:
1. Insert a small screwdriver into the pry-off slots at the bottom of the unit and twist
to remove the back cover.
2. Observing correct polarity, replace the battery (9V, alkaline).
3. Replace the back cover making sure that the two covers click shut.
9V Alkaline
Battery
Tamper
Switch
Buzzer
Figure B.15: EL-2620 (back cover off)
Battery Replacement (EL-2640)
When the battery is low, the EL-2640’s LED flashes
during transmission.
To replace the battery:
1. Remove the battery cover located at the
rear of the unit. To do so, press the release
tab using a small screwdriver and lift the
cover away from the EL-2640’s plastic
housing.
2. Observing correct polarity, replace the
battery (9V, alkaline).
3. Replace the battery cover making sure that
it clicks shut.
9V Alkaline
Battery
Figure B.16: EL-2640
(battery cover off)
-82-
Transmitter Specifications
The technical specifications for the transmitters that appear in this appendix are listed
below. All transmitters are available in 868.35, 433.92 or 418MHz FM frequencies.
EL-2600
Antenna: Built-in Whip
Power: 3.6V ½ AA Lithium Battery
Current Consumption: 30mA (transmission)
6µA (standby)
Pyroelectric Sensor: Dual Element
Maximum Coverage: 14 x 14m
Pulse Count: 1, 2 or 3 Jumper Selectable
LED Indicator: Jumper Selectable
Adaptive Temperature Compensation
RFI Immunity: 30V/m
Operating Temperature: -10 to 60°C
Fire Protection: ABS Plastic Housing
Dimensions: 110 x 60 x 45mm
EL-2600PI
Antenna: Built-in Whip
Power: 3.6V ½ AA Lithium Battery
Current Consumption: 30mA (transmission),
6µA (standby)
Pyroelectric Sensor: Dual Element
Maximum Coverage: 12 x 12m
Pulse Count: 1, 2 or 3 Jumper Selectable
LED Indicator: Jumper Selectable
Adaptive Temperature Compensation
RFI Immunity: 30V/m
Operating Temperature: -10 to 60°C
Fire Protection: ABS Plastic Housing
Dimensions: 110 x 60 x 45mm
EL-2645
Antenna: Built-in Whip
Power: 3.6V ½ AA Lithium Battery
Current Consumption: 30mA (transmission)
12µA (standby)
Pyroelectric Sensor: Dual Element
Maximum Coverage: 14 x 14m
Pulse Count: 1, 2, 3 or Adaptive
LED Indicator: Selectable
Adaptive Temperature Compensation
RFI Immunity: 30V/m
Operating Temperature: -10 to 60°C
Fire Protection: ABS Plastic Housing
Dimensions: 110 x 60 x 45mm
EL-2645PI
Antenna: Built-in Whip
Power: 3.6V ½ AA Lithium Battery
Current Consumption: 30mA (transmission),
12µA (standby)
Pyroelectric Sensor: Dual Element
Maximum Coverage: 12 x 12m
Pulse Count: 1, 2, 3 or Adaptive
LED Indicator: Selectable
Adaptive Temperature Compensation
RFI Immunity: 30V/m
Operating Temperature: -10 to 60°C
Fire Protection: ABS Plastic Housing
Dimensions: 110 x 60 x 45mm
EL-2601/EL-2602
Antenna: Built-in Whip
Power: 3.6V ½ AA Lithium Battery
Current Consumption: 25mA (transmission)
10µA (standby)
Loop Input Voltage Range: 0-15VDC/AC
(peak to peak)
RFI Immunity: 40V/m
Operating Temperature: 0 to 60°C
Dimensions: 65 x 30 x 25mm
EL-2603
Antenna: Built-in Internal Whip
Current Consumption: 30mA (transmission),
20µA (standby)
Power: 9V Alkaline Battery
RFI Immunity: 40V/m
Operating Temperature: 0 to 60°C
Dimensions: 138 x 118 x 44mm
EL-2606
Antenna: Built-in Whip
Power: 3.6V ½ AA Lithium Battery
Current Consumption: 25mA (transmission)
30µA (standby)
Microphone: Omni-directional electret
Maximum Range: 6m (plate, tempered,
laminated and wired glass)
3.65m (armor-coated glass)
RFI Immunity: 20V/m
Operating Temperature: 0 to 50°C
Dimensions: 80 x 108 x 43mm
-83-
EL-2611
Antenna: Built-in Whip
Power: Non-replaceable battery
RFI Immunity: 40V/m
Operating Temperature: 0 to 60°C
Dimensions: 60 x 40 x 15mm
EL-2614
Antenna: Built-in Whip
Power: 2 x 3V Lithium Battery
Size CR1225
Current Consumption: 16mA (transmission)
2µA (standby)
RFI Immunity: 40V/m
Operating Temperature: 0 to 60°C
Dimensions: 62 x 42 x 15mm
EL-2620
Antenna: Built-in Whip
Current Consumption: 26mA (transmission)
2µA (standby)
Power: 9V Alkaline Battery
RFI Immunity: 40V/m
Operating Temperature: 0 to 60°C
Dimensions: 130 x 110 x 28mm
EL-2640
Antenna: Built-in Whip
Current Consumption: 25mA (transmission)
3µA (standby)
Power: 9V Alkaline Battery
RFI Immunity: 40V/m
Operating Temperature: 0 to 60°C
Dimensions: 128 x 49 x 27mm
Lithium Batteries
!
Fire, explosion and severe burn hazard!
When handling lithium batteries follow the listed precautions:
• Do not recharge.
• Do not deform or disassemble.
• Do not heat above 100°C or incinerate.
,
Due to the occurrence of voltage delay in lithium batteries that have been
in storage, the batteries may initially appear to be dead. In this case,
leave the unit in Test mode or Radio mode for a few minutes until the
battery voltage level is stabilized.
-84-
Appendix C: Event Table
Burglary
Description
Alarm from Zone
Zone Alarm Restore
Zone Bypassed
Zone Unbypassed
Zone Tamper
Zone Tamper Restore
Zone Panic Alarm
Zone Panic Restore
Panic Alarm
Tamper
Tamper Restore
Duress
Bell Cancel
Disarm after Alarm
Water Alarm
Water Alarm Restore
Environmental Alarm (untyped)
Environmental Alarm Restore
Restore
Š
Š
Š
Š
Š
Š
Š
Š
Š
Š
Š
Š
Š
SIA
NBA
NBR
NUB
NUU
NTA
NTR
NPA
NPR
NPA
NTA
NTR
NHA
Contact ID
1130
3130
1570
3570
1137
3137
1120
3120
1120
1137
3137
1121
Address Field
Device Number
Device Number
Device Number
Device Number
Device Number
Device Number
Device Number
Device Number
Device Number
Device Number
Device Number
—
1521
1458
1154
3154
1150
3150
User Number
User Number
Device Number
Device Number
Device Number
Device Number
Š
Š
Š
Š
NBC
NOR
NWA
NWH
NUA
NUH
Š
Š
NFA
NFR
1110
3110
Device Number
Device Number
NCL
NCG
NCG
NOP
3401
3456
3441
1401
User Number
User Number
User Number
User Number
User Number
User Number
Fire
Fire Alarm
Fire Alarm Restore
Open/Close
Full Arm
Part Arm
Perimeter Arm
Disarm
Service
Edit User Code
Delete User Code
System Programming
Š
Š
Š
NJV
NJX
NLB
1462
3462
1627
End System Programming
Š
NLX
1628
Remote Programming
Š
NRB
1412
End Remote Programming
Š
NRS
3412
Periodic Test
Š
NRP
1602
Walk Test
End Walk Test
Š
Š
NTS
NTE
1607
3607
User Number
Set Time
Set Date
Clear Log
No Arm
Š
Š
NJT
NJD
NLB
NCD
1625
1625
1621
1654
User Number
User Number
User Number
Š
= Events that are displayed in the event log only when viewed by the installer.
-85-
—
—
—
—
—
—
—
Power
Description
Battery Low
Battery Restore
Transmitter Low Battery
Transmitter Battery Restore
AC Loss
AC Restore
Restore
SIA
NYT
NYR
NXT
NXR
NAT
NAR
Contact ID
1302
3302
1384
3384
1301
3301
Š
NLT
NLR
NET
NER
NUT
NUR
NUT
NUR
NUS
NUR
NYY
NBT
NBJ
1351
3351
1330
3330
1341
3341
1341
3341
1381
3381
1605
1380
3380
Device Number
Device Number
Device Number
Device Number
Device Number
Device Number
Device Number
Device Number
Device Number
Device Number
Signal Level (0-9)
Device Number
Device Number
Š
Š
Š
NXQ
NXH
1344
3344
Device Number
Device Number
Š
Š
NMA
NMR
1100
3100
Device Number
Device Number
Š
Š
Š
Address Field
Device Number
Device Number
Device Number
Device Number
Device Number
Device Number
Peripherals
Media Loss
Media Loss Restore
Device Trouble
Device Trouble Restore
Transmitter Out of Synch.
Transmitter Re-synch.
CP Transmitter Out of Synch.
CP Transmitter Re-synch.
Supervision Loss
Supervision Restore
GSM Signal Level
Zone Trouble
Zone Trouble Restore
Š
Š
Š
Š
Š
Š
Š
Š
Š
Š
Š
Š
Š
Š
Š
Š
Š
Š
RF Jamming
FM Jamming
FM Jamming Restore
Medical
Medical Alarm
Medical Alarm Restore
Address Field
The address field provides additional information regarding the event. This information is
forwarded as numeric data according to the following tables.
Value
01-32
33
41-48
65
77-80
81-84
91
243
244
DEVICE NUMBER
Description
Wireless Zones
Hardwire Zone
Keyfobs
Home Automation Module
Repeaters
Wireless Keypads
Front Panel Keypad
PSTN Module
Cellular Communications Module
Value
00
01-32
34
41-48
61-76
81-84
91
-86-
USER NUMBER
Description
Control Panel
Users
Remote Access
Keyfobs
Smartkeys
Wireless Keypads
Front-panel Keypad
ELECTRONICS LINE 3000 Ltd. - LIMITED WARRANTY
ELECTRONICS LINE 3000 Ltd. (hereafter “EL3K”) warrants its products to be free from manufacturing defects in
materials and workmanship for (Wireless – 12 months excluding batteries, Control Panels – 2 years, Dual
Technology Detectors – 2 Years, PIR Detectors - 5 years) following the date of sale. EL3K will, within said period,
at its option and in accordance with the terms of this Limited Warranty, repair or replace any product failing to
operate correctly without charge to the original purchaser or user. In case of defect, contact the security
professional who installed and maintains your security system. In order to exercise the warranty, the product
must be returned by the user or purchaser, shipping costs prepaid and insured to EL3K. EL3K will not be
responsible for any dismantling or reinstallation changes.
This warranty shall not apply to any equipment, or any part thereof, which has been repaired by others,
improperly installed, improperly used, abused, altered, damaged, subjected to acts of God, or on which any serial
numbers have been altered, defaced or removed, or on a product in which the fault does not prevent the use of
the product at the installation site, or in the system to which the product is connected.
There is no express or implied warranty of merchantability or warranty of fitness for a particular purpose.
Any action for breach of warranty, including but not limited to any implied warranty of merchantability, must be
brought within the six months following the end of the warranty period. In no case shall EL3K be liable to anyone
for any consequential or incidental damages for breach of this or any other warranty, express or implied, even if
the loss or damage is caused by the EL3K's own negligence or fault.
In no event shall EL3K be liable for an amount in excess of EL3K's original selling price of the product, for
any loss or damage, whether direct, indirect, incidental, consequential, or otherwise arising out of any failure of
the product. CONSEQUENTLY, EL3K SHALL HAVE NO LIABILITY FOR ANY PERSONAL INJURY, PROPERTY
DAMAGE, OR OTHER LOSS BASED ON A CLAIM THE PRODUCT FAILED TO GIVE WARNING. EL3K's
warranty, as herein above set forth, shall not be enlarged, diminished or affected by and no obligation or liability
shall arise or grow out of EL3K's rendering of technical advice or service in connection with Buyers order of the
goods furnished hereunder.
This warranty contains the entire warranty. Additionally, this warranty is in lieu of all other obligations or
liabilities on the part of EL3K It is the sole warranty and any prior agreements or representations, whether oral or
written, are either merged herein or are expressly canceled. EL3K neither assumes, nor authorizes any other
person purporting to act on its behalf to modify, to change, or to assume for it, any other warranty or liability
concerning its products.
EL3K RECOMMENDS THAT THE ENTIRE SYSTEM BE COMPLETELY TESTED WEEKLY.
Warning: Despite frequent testing, and due to, but not limited to, any or all of the following: criminal
tampering, electrical or communications disruption, it is possible for the system to fail to perform as expected.
EL3K does not represent that the product/system may not be compromised or circumvented; or that the product
or system will prevent any personal injury or property loss by burglary, robbery, fire or otherwise; nor that the
product or system will in all cases provide adequate warning or protection. A properly installed and maintained
alarm may only reduce risk of burglary, robbery, fire or otherwise but it is not insurance or a guarantee that these
events will not occur. Therefore, the installer should in turn advise the consumer to take any and all precautions
for his or her safety including, but not limited to, fleeing the premises and calling police or fire department, in order
to mitigate the possibilities of harm and/or damage.
EL3K is not an insurer of either the property or safety of the user's family or employees, and limits its liability for
any loss or damage including incidental or consequential damages to EL3K’s original selling price of the product
regardless of the cause of such loss or damage. If the user wishes to protect itself to a greater extent, EL3K will,
at user's sole cost and expense, obtain an insurance policy to protect the user, supplemental to user's own policy,
at a premium to be determined by EL3K's insurer upon written notice from user by Certified Mail, Return Receipt
Requested, to EL3K's home office address, and upon payment of the annual premium cost by user.
Some states do not allow limitations on how long an implied warranty lasts or do not allow the exclusion or
limitation of incidental or consequential damages, or differentiate in their treatment of limitations of liability for
ordinary or gross negligence, so the above limitations or exclusions may not apply to you. This Warranty gives
you specific legal rights and you may also have other rights that vary from state to state.
-87-

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement