Click Here For User Manual
USER MANUAL
LED Flower 7x4
DMX-controlled RGBW 7-Cluster LED Effect
ENGLISH Page 2-12
RevA 11/2009 Order code: 12-015-0053-80100-1-01
User Manual: LED Flower 7x4
User Manual: LED Flower 7x4
■ Introduction
Termination
To avoid interference the last unit of a DMX-chain should be terminated. Use a
standard 120 Ohms XLR termination plug for DMX lines on the last device in a DMX
bus chain.
Dear customer,
congratulations on the purchase of this quality item and the trust having been put in us
with this decision. To take full advantage of all possibilities and for your own safety and
the safety of your environment, please read these operating instructions carefully
before you start using the unit.
Switch on condition
The unit always returns to the last mode before it was switched off. In DMX Slave “SLA”
or DMX Mode “d1”/”d3” all DMX values are cleared if power is switched off.
■ Security advice before use
DMX signal drop condition
Warning: Read this section carefully before installing, powering,
operating, cleaning or servicing this product!
The device will retain the status that it was in before the DMX signal got lost, but
potential tact settings will be automatically cleared.
The following symbols are used to identify important safety information in this manual:
DANGER!
Safety hazard. Risk
of injury or death.
WARNING!
Hazardous voltage.
Risk of severe or
fatal electric shock.
WARNING!
Fire hazard.
WARNING!
Read manual before
installation and
operation.
General advice:
1. Read this manual completely before using the product.
2. Keep this manual in your records for future reference.
3. Follow all instruction printed in this manual, otherwise warranty
may be void.
4. Follow all printed security advice on the product itself. The lighting
flash with arrowhead within an equilateral triangle makes you
aware of non-insulated AC mains voltage inside the unit. The
exclamation mark within an equilateral triangle makes you aware of
important operating and maintenance instructions in the literature
attached to this product.
5. Take care of enough distance between this product and sources of
hum and noise like electric motors and transformers.
6. Carry this product with greatest care. Punches, big forces and
heavy vibration may damage this product mechanically.
7. The manufacturer takes no responsibility for injury or damage
caused by not following the safety precautions and instructions
printed in this manual.
■ Maintenance
This unit does not need regular maintenance. The internal circuit is protected by a
250V/2A slow-blow fuse 5x20mm fuse. If this fuse fails, this usually indicates an
internal fault requiring servicing by a qualified engineer. The fuse shall only be replaced
by a fuse of same specification, and the replacement has to be made by qualified
personnel obeying applicable safety rules.
■ Technical data LED Flower 7x4:
LEDs…..……...............……469 pcs. 5mm LEDs (175 R, 70 G, 33 B, 91 W) in 7 clusters
Mains Input……………………………………………………………. AC90-250V~ 50/60Hz
Power supply type………………………………………………………….……..switch mode
Power Consumption…………………….…………………………………………...max. 34W
DMX connections…………………………………………………3 pin XLR (Male / Female)
Control protocol.......................................................................................DMX 512 (1990)
Dimensions (with bracket)………...…………………….………. LxWxH: 247x275x330mm
Weight …………………………………………………………………………………….3.82kg
■ Standards
This product complies with the following standards:
EU safety................................................................EN60598-1:2008, EN60598-2-1:1989
EU EMC.......................................EN55015: 2006 + A1:2007, EN61547:1995 + A1:2000
EU Harmonics ...................................................................................EN61000-3-2:2006
EU Flicker ………………………………………………………………….EN61000-3-3:2008
US safety ………….…………..………………………………………………………UL60065
US EMC………………………..…………………………………………………..FCC Part 15
This product meets both the EMC Directive 2004/108/EC and the Low Voltage Directive
2006/95/EC.
V1.00 (11-2009)
2
V1.00 (11-2009)
11
User Manual: LED Flower 7x4
User Manual: LED Flower 7x4
Warning! Class 1M LED product.
1. Do not look into the beam from a distance of less than 40 cm (16
inches).
2. Do not stare into the beam for extended periods at a short
distance.
3. Do not view the beam directly with optical instruments such as
magnifiers.
■ Slave Operation
The LED Flower 7x4 has a sophisticated ability to not only generate a DMX signal
equivalent to its own behaviour at its DMX output on channels 001…003, but also a
DMX signal representing the same pattern that currently plays, but shifted by several
pattern steps on channels 004…006. A connected slave unit can be either set to
“synchronous” slave mode (setting “S” in menu “SLAVE”), then using the channels
001…003, or asynchronous slave mode (setting “A” in menu “SLAVE”), then using the
channels 004…006.
Protection from electric shock:
1. Do not connect the AC power plug to the unit before assembly has
been completed.
2. Only connect this unit to a mains socket outlet with protective earth
connection, ground-fault (earth-fault) protection and overload
protection.
3. Where the mains plug or an appliance coupler is used as a disconnect device, the disconnect device shall remain readily
operable.
4. To pull the AC Cord out of the wall outlet or the unit’s AC socket,
never pull the cable itself, but only the AC plug.
5. Disconnect the unit from AC supply by pulling the AC plug out of
the wall outlet or the unit’s AC socket before any kind of cleaning
on the product. Use smooth and dry cloth only for cleaning. Check
all connection cables before reconnecting the unit.
6. Do not expose this unit to any dripping or splashing liquids, and do
not place objects filled with liquids, such as vases, on the unit. Do
not operate this unit near to open water or in high humidity.
7. Choose the position of the AC cord according to the lowest risk of
damage by foot steps or by squeezing it. Take especially care of
the AC cord outlet on the unit as well as the AC plug and wall outlet
at the other end of the cable.
8. Do not open the unit for service purpose, as there are no userserviceable parts inside. Warranty will be void in any case of
unauthorized service by the user or other not authorized persons.
As the control signal for the slave is generated in the master unit, the settings for the
offset of a connected slave in asynchronous slave mode (setting “A” in menu “SALVE”)
must be made in the master unit. The number of pattern steps (amount of shift) can be
selected in the Output menu.
The output menu is accessible by pressing the MODE (1) and DOWN (3) button at the
same time, until the display shows “OPx”, indicating operation in “OP” (Output) mode,
with “x” being a number from 1 through to 4; the display can hence show the values
OP1/OP2/OP3 and OP4. The number “x” represents the number of pattern steps by
which the slave signal generated on DMX channel 004…006 is shifted against the
synchronius slave signal. The setting can be adjusted using the UP/DOWN buttons
(2/3). If no further settings are made inbetween 3 seconds, the unit will automatically
return to the menu shown before switching into “OPx” (output) mode.
For master/slave operation, also see the below example:
Protection from fire:
1. Take care of not placing the unit near sources of heat (e.g.
powerful amplifiers, fog machines).
2. Allow at least about 6” (15cm) between this unit and other devices
or a wall to allow for proper cooling.
3. Be sure this fixture is kept at least 0.5m away from any flammable
materials (decoration etc.).
4. Do not stick filters, masks or other materials directly on the LEDs or
the LED cover screen.
5. Take always care of sufficient air convection in the unit’s
environment to avoid overheating, especially when mounting in a
closed environment. Make sure air convection slots are not
V1.00 (11-2009)
10
V1.00 (11-2009)
3
User Manual: LED Flower 7x4
6.
User Manual: LED Flower 7x4
blocked. Do not operate this unit in environmental temperatures
exceeding 35 degrees Celsius.
Check the total maximum power of your AC wall outlet if you
connect several units to one wall outlet and avoid any overloading.
Protection from injury and damage:
1. Never use any accessories or modifications not authorized by the
manufacturer of this unit.
2. Choose a location for operation where the unit is protected from
vibration and where a fixed mounting position is provided. In case
of overhead-mounting, follow appropriate rigging rules and your
country’s regulations for rigging safety. See appendixes if any.
3. Before plugging the AC cord in the wall outlet, check whether the
AC mains voltage and frequency is the same as this product is
specified for. Whenever your AC plug should not match the wall
outlet, contact you dealer immediately.
4. If fluids have spilled into the unit or small parts have intruded the
unit, immediately switch off the unit and hand it over to the
authorized service for a security check.
5. Disconnect the unit from AC supply by pulling the AC plug out of
the wall outlet or the unit’s AC socket during a thunder-storm in
order to avoid any damage on the unit due to AC voltage peaks.
6. In cause of not correct function of this unit or damaged AC cord or
other damaged parts, pull immediately the AC plug out of the wall
outlet and hand the unit over to the authorized service for a
security check.
7. To meet all aspects of functionality and security during maintenance work to be preformed on this unit, all parts should be
replaced by genuine spare parts. Consequently, take care of your
dealer or maintenance company to be authorized by the
manufacturer.
“d1” Mode (DMX “Easy” Mode)
Press the MODE button (1) until the display shows “d1”, indicating operation in “d1”
(DMX Easy) mode. In alternation with displaying “d1”, the display will show the DMX
start address, which the user can change using the UP/DOWN buttons (2/3).
In this mode, the unit receives a DMX control signal on only one channel which is
chosen as the start address, and mirrors the received data on the DMX output. Purpose
of this mode is to allow simple basic remote settings for the user who is not familiar indepth with DMX, but still would like to remotely enable or disable the unit and change
the most vital operation parameters. The functional assignment to the receiving channel
is as below:
CH1 DMX values:
000..014
015..059
060..104
105..149
150..199
200..249
250..255
Off
Various patterns (9 patterns, low speed)
Various patterns (9 patterns, medium speed)
Various patterns (9 patterns, fast speed)
10 pattern loop + Strobe (various speeds)
Single pattern loop (10 patterns, sound-to-light)
10 pattern loop (sound-to-light)
“d3” Mode (DMX “Full” Mode)
Press the MODE button (1) until the display shows “d3”, indicating operation in “d3”
(DMX Full) mode. In alternation with displaying “d1”, the display will show the DMX start
address, which the user can change using the UP/DOWN buttons (2/3).
In this mode, the unit receives a DMX control signal on a packet of three consecutive
DMX channels, starting from the start address as set above, and mirrors the received
data on the DMX output. Purpose of this mode is to allow more in-depth control for the
discerning user who looks for specific effects. The functional assignment to the
receiving channels is as below:
■ Health advice
This unit produces and absorbs electromagnetic radiation. The strength of radiation and
the sensitivity for disturbing interference matches the CE and FCC requirements. A
corresponding sign is printed on the backside of the unit. Any change or modification
may affect the behavior of the unit concerning electromagnetic radiation, with the CE
requirements eventually not to be met any more. The manufacturer takes no
responsibility in this case.
CH1 (Play):
000
001...199
200
201…254
255
All off
Static Pictures
All on
Chase Patterns
All pattern loop after 4 cycles
CH2 (Speed):
000
001...149
150…175
176…200
201…255
Static
Speed 31…180 BPM (1 BPM steps)
Sound-to-Light (1 step per 4 Beats)
Sound-to-Light (1 step per 2 Beats)
Sound-to-Light (1 step per 1 Beat)
CH3 (Strobe):
000…010
011…255
Strobe off
Strobe 1Hz…23Hz
■ Functional advice
This unit is immune to the presence of electromagnetic disturbances – both conducted
and radiated - up to a certain level. Under peak conditions, the unit is classified to show
a “class C” performance criteria and may encounter temporary degradation or loss of
V1.00 (11-2009)
4
V1.00 (11-2009)
9
User Manual: LED Flower 7x4
User Manual: LED Flower 7x4
replay speed can be set in ten steps by means of the UP (2) and DOWN (3) buttons.
function which may need manual help to recover. In such case, disconnect the AC
power from the unit and reconnect it again to recover.
In “A” mode, the unit does not receive any values from the DMX input but runs through
its own patterns and creates related DMX values on the output with channels 001 to
003 so that similar units can show the same chase pattern if they are connected by
DMX and set to ”Slave”. It further generates a second set of control signal on channels
004 to 006, which are shifted against the signal present on channels 001 to 003 by a
selectable amount of pattern steps. See chapter “slave operation”.
If you leave mode “A” for any reason and come back later into mode “A”, the unit will
recall the last chosen patterm preset (even if the unit was switched off in between). The
factory default is A1.
■ Environmental advice
This unit is build to conform to the ROHS standards and the WEEE
directive 2002/96/EC of the European Parliament and of the Council of
the European Union. Under these regulations, the product shall not be
discarded into regular garbage at the end of its life, but shall be returned
to authorized recycling stations.
■ Unpacking
Please check that the box contains the following items:
“S2L“ Mode (Sound-to-Light Mode)
Main parts:
Press the MODE button (1) until the display shows “S2L”, indicating operation in “S2L”
(Sound to Light) mode. In this mode, a sequence of different preset pictures is played,
while the trigger to switch to the next picture is provided by external audio picked up by
the internal microphone. In S2L mode, the UP/DOWN buttons (2/3) are disabled.
1 pcs. LED Flower 7x4 main unit
1 pcs. mains cable
1 pcs. operation manual
If any part is missing, please contact your dealer immediately for replacement.
In “S2L” mode, the unit does not receive any values from the DMX input but runs
through its own picture presets and creates related DMX values on the output with
channels 001 to 003 so that similar units can show the same picture if they are
connected by DMX and set to ”Slave”. It further generates a second set of control
signal on channels 004 to 006, which are shifted against the signal present on channels
001 to 003 by a selectable amount of steps. See chapter “slave operation”.
■ Getting started: choosing a location
“SLA” Slave Mode
Do not:
Operate the LED Flower 7x4 in environments with more than 35 degrees
environmental temperature or more than 75% relative humidity.
Operate the LED Flower 7x4 in any closed environment smaller than 10cbm,
unless forced air convection is provided.
Press the MODE button (1) until the display shows “SLA”, indicating operation in “SLA”
(Slave) mode. In alternation with displaying “SLA”, the display will show either the letter
“S” (for “synchronous”) or “A” (for “asynchronous“), while the user can change between
these two setting using the UP/DOWN buttons (2/3). When being in “SLA” mode with
setting “S” (synchronous), the unit will receive a control signal on DMX channel
001…003 (3 channels), while when being in “SLA” mode with setting “A”
(asynchronous), the unit will receive a control signal on DMX channel 004…006 (3
channels).
Risk of fire: The LED Flower 7x4 has been designed to work in dry
indoor environments at environmental temperatures up to 35 degrees
Celsius. For proper operation, the unit must be operated with
unobstructed air convection to its outside metal case.
■ Getting started: making AC supply connections
Risk of fire / Safety risk
The LED Flower 7x4 has an AC outlet that is designed to carry loads of
no more than 8A. Do not connect any high-power devices such as
audio power amplifiers, fog machines etc. to this outlet. Make sure that
all connected devices in a chain fed by the first device do not exceed a
maximum of 8A current consumption. All units must be properly and
separately earthed.
Bearing in mind that any unit being in “A” or “S2L” mode acts as a master, and does not
only generate its own played pattern as a DMX signal on channels 001…003, but also
the same pattern with selectable shift (see “slave operation”) on channels 004…006,
then switching between setting “S” and “A” in slave mode allow the slave unit to either
play in synchronisation (“S”) of shifted against the master (“A”).
V1.00 (11-2009)
8
V1.00 (11-2009)
5
User Manual: LED Flower 7x4
User Manual: LED Flower 7x4
■ Getting started: secure mounting
■ General Operation
Hanging/Rigging, ceiling-mounted operation
Risk of injury: Overhead mounting requires extensive experience,
including among others calculating working load limits, good knowledge
of the installation material being used, and periodic safety inspection of
all installation material and the unit. If you lack such qualifications, do
not attempt the installation yourself. Improper installation can result in
body injury. Be sure to complete all rigging and installation procedures
before applying power to the unit.
•
•
•
•
•
•
•
•
The unit should be installed out of reach of people and outside areas where
persons may walk by or be seated.
Make sure that the installation area can hold a minimum point load of 10 times the
device’s weight.
In fixed installations, fix the unit with self-locking screws/nuts to the mounting point.
When mounting the unit to truss be sure to secure an appropriately rated clamp to
the hanging yoke using a M10 screw fitted through the center hole of the hanging
yoke.
Where required, secure the installation with an appropriate safety cable. Always
use a certified safety cable that can hold 12 times the weight of the device when
installing the unit. This secondary safety attachment should be installed in a way
that no part of the installation can drop more than 20cm if the main attachment
fails.
Never stand directly below the device when mounting, removing, or servicing the
fixture. Make sure the area below the installation place is free from unwanted
persons during rigging, de-rigging and servicing.
The operator has to make sure that the safety-relating and machine-technical
installations are approved by an expert before using them for the first time. The
installations should be inspected every year by a skilled person to be sure that
safety is still granted.
Make sure to comply with cooling requirements of the used power supply if any.
User interface overview:
1
2
3
4
5
6
7
8
MODE selection button
UP-Button
DOWN-Button
Display showing the Mode, DMX-address, etc.
DMX input
DMX output
AC output
AC input
Upon the user’s choice, the unit can work stand-alone or may be controlled by external
DMX-controllers. Available modes:
“A” Mode (Auto / DMX Master)
Press the MODE button (1) until the first digit on the display show “A”, indicating
operation in “A” mode. In this mode, a varied preset pattern is replayed, for which the
V1.00 (11-2009)
6
V1.00 (11-2009)