TABLE OF CONTENTS
BEFORE USING THE SCALE ......................................................................................... 2
PREPARING TO USE THE SCALE ................................................................................ 2
CHAPTER 1 FEATURES AND SPECIFICATIONS ...................................................... 3
CHAPTER 2 DISPLAY ...................................................................................................... 4
CHAPTER 3 KEYBOARD FUNCTION.......................................................................... 5
3-1 Explanation of Keyboard............................................................................................. 5
3-2 Basic Function Operation ............................................................................................ 6
3-2-1 Switching the scale on / Re-zeroing...................................................................... 6
3-2-2 The desired units selection.................................................................................... 6
3-2-3 The weight value of the container deduction........................................................ 6
3-2-4 Net / gross weight value cross-display.................................................................. 6
3-2-5 Counting mode ...................................................................................................... 7
CHAPTER 4 ADVANCED FUNCTION SETTINGS...................................................... 8
4-1 Auto Power off and Backlight Setting......................................................................... 8
4-2 Hold Function Setting.................................................................................................. 9
1
SME300000099
BEFORE USING THE SCALE
Thank you for purchasing the Electronic Weighing Scale. In order to use the scale properly,
please read this User Manual carefully before use. If you have a problem concerning the
scale, please contact your supplier.
1. Please keep scale in a cool and dry place. Do not store at high temperatures.
2. Do not allow any liquids to come into or contact with the scale. If it is happened, wipe the scale
dry with a cloth.
3. Avoid objects impacting with the scale. Do not drop loads onto the scale or subject the weigh pan
to any strong shock loads.
4. The load placed on the weigh pan must not exceed the maximum weighing capacity of the scale.
5. If the scale is not going to be used for some time, please clean it and store it in a plastic bag in dry
conditions. A desiccant sachet may be included to prevent moisture build up.
PREPARING TO USE THE SCALE
1. For accurate weight readings locate the scale on a firm level surface free from vibrations.
2. Avoid operating the scale in direct sunlight or drafts of any kind.
3. Remove any weight that might be on the weigh pan before the scale is switched on and avoid
leaving weight on the pan for long periods of time.
4. Once the scale has been switched on, it will go through a LCD display test and then re-zero to be
ready for use.
5. The scale requires 15~20 minutes warming up the machine before operation to ensure best
accuracy.
6. Please note when
symbol appears on the screen, the dry batteries need to be replaced or
the recharge the battery.
7. All goods weighed should be placed in the centre of the weigh pan for accurate weighing. The
overall dimensions of the goods being weighed should not exceed the dimension of the weigh pan.
2
SME300000099
CHAPTER 1 FEATURES AND SPECIFICATIONS
Features:
n
Multi-function operation: Fast weighing operation; Full range tare; Net / Gross weight display;
Simple counting (pcs); Auto power-off; Weight hold feature.
n
Dual-weighing units: kilogram (kg) and pound (lb) depend on request.
n
User-friendly design: Auto calibration; Large LCD display; Gravity compensation; low battery
warning indicator; double over-load protection.
Product Package:
n
Scale 1 off
n
User manual 1 off
Please contact to your supplier, if any of the items described above are missing.
3
SME300000099
CHAPTER 2 DISPLAY
3
4
5
1
6
2
TARE
1
: “Tare” indication.
ZERO
2
: “Zero” indication.
►
3
: Kilogram (g), the 1st unit indication.
►
4
: Pound (lb), the 2nd unit indication.
►
5
: None.
►
6
: Piece unit (pcs), the 4th unit indication.
: “Low Battery” indication.
4
SME300000099
CHAPTER 3 KEYBOARD FUNCTION
3-1 Explanation of Keyboard
1.
OFF
: The key to switch the scale off.
2.
ON
ZERO
: ON/ZERO key.
When the scale is off, press the key to switch it on.
When the scale
is switched on, with the weigh pan empty, if the display is not showing zero, press this key to zero
(balance) the scale.
v Zero range: ± 2% of full scale (Standard, OIML & NTEP models), ± 4% of full scale (Sri Lanka
model).
3.
TARE
: TARE key. Press the key to deduct the weight of the container.
v The tare key is not functional when the weight value shown on the display is negative or over the
full scale capacity.
4.
UNITS
: Units key.
5.
NET
GROSS
: Gross weight / Net weight key.
Press the key to select the desired weight units or count units (pcs).
The gross weight = Tare weight + Net weight
(The key is ONLY functional in the Tare mode)
5
SME300000099
3-2 Basic Function Operation
3-2-1 Switching the scale on / Re-zeroing
1.
2.
ON
ZERO
When the scale is off, press
key to turn the scale on.
When the scale is on and without any object placed on the weigh pan, press
ON
ZERO
key to
obtain a zero reading. ”◄” the 2nd indication shows in the left hand side of the display.
3-2-2 The desired units selection
UNITS
Press the
key to select gram (g), ounce (oz) or pcs, ” ►” the indication will show in the right
hand side of the display. After power off, the scale will memorise the active units. When the scale is
powered on again, it displays the previous active units.
3-2-3 The weight value of the container deduction
1.
Place the container on the weigh pan. After stable, press
TARE
key to deduct the weight value of
the container.
2.
Place the object in the container, the scale will show the net weight value of the object.
3.
Remove the container and weighing object, and the display shows the negative weight value of the
container. Press
TARE
key to clear the weight value of the container, and ”◄” the first
indication goes off.
v Tare continuously (Press TARE
key, when weight is added or deducted on the weigh pan).
v Tare value = The full capacity (The scale can be tarred continuously to the full capacity).
3-2-4 Net / gross weight value cross-display
1.
In the tare mode, the display shows ”◄” the 1st indication on the left hand side. Press
NET
GROSS
key to show the gross weight value, and ”◄” the indication goes off.
2.
Press
NET
GROSS
key again, the display shows the net weight value and ”◄” the 1st indication shows
again.
3.
The
NET
GROSS
key is ONLY functional in the tare mode.
6
SME300000099
3-2-5 Counting mode
1.
Press
2.
Press
UNITS
NET
GROSS
,
3.
key to select piece unit (pcs), and enter the counting mode.
key to select the counting sample size 10, 20, 50, 100, or 200, and the display shows
,
,
, or
UNITS
. The display shows “
Place the samples on the weigh pan, then press
”. After the
weight is stable, the scale shows the quantity of the samples. After the sampling process is complete,
put the goods on the weigh pan and the screen shows the quantity of the goods.
v The scale memorizes the selected sample quantity, after turning off the scale. The scale will show the same
selected sample quantity, when entering the counting mode next time.
v If the quantity of the items weighed larger than 65536 (pcs), the display shows the error message “
7
”.
SME300000099
CHAPTER 4 ADVANCED FUNCTION SETTINGS
4-1 Auto Power off and Backlight Setting
Switch on the scale, press
ON
ZERO
and
NET
GROSS
keys together to enter the advance function
。
setting mode. The display shows
The display shows the last setting
Auto power-off setting
Auto power off timer setting
Press the ON/ZERO key to enter a parameter.
0 ⇒ No auto power-off
1 ⇒ When the scale is idle for 1 minute, the scale
automatically switches off
2 ⇒ When the scale is idle for 2 minutes, the scale
automatically switches off
Press the ON/ZERO key to
enter a parameter
Press the TARE key
19 ⇒ When the scale is idle for 19 minutes, the
scale automatically switches off
Press the ON/ZERO key to
enter a parameter
The display shows the last backlight setting
Auto backlight setting
Press the ON/ZERO key to enter a parameter.
ON/ZERO
TARE
⇒ Increment digit (from 0 to 9)
on ⇒ Auto Backlight on
off ⇒ Auto Back light off
⇒ Confirm / enter key
NET/GROSS
⇒ Move the cursor to the right
Automatic power-off function
When the weight on weigh pan is less than 10d or remains steady for the set time, the scale will
automatically switch off.
v Automatic power-off is not functional, when using an ac adaptor as the power source. Therefore,
auto power-off is ONLY active, when using dry batteries as the power source.
Auto Backlight Function
When the weight is over 10d, the backlight is on. After the weight is stable for 10 seconds or when
the scale returns to zero, the backlight switches off.
8
SME300000099
4-2 Hold Function Setting
Hold function setting
LCD displays the last parameter setting
Use the ON/ZERO key to
enter a parameter
Hold function setting
Use the ON/ZERO key to input a parameter
Default setting = 0
0 ⇒ Hold function disabled
1 ⇒ “Peak hold” mode
2 ⇒ “Stable hold 1” mode
3 ⇒ “Stable hold 2” mode
Press the TARE key to
complete the advance function
setting
Back to weighing mode
ON/ZERO
TARE
⇒ Increment digit (from 0 to 9)
⇒ Confirm / enter key
NET/GROSS
⇒ Move the cursor to the right
= Hold function disabled.
= “Peak hold” mode
The scale shows the maximum weight value detected from the continuously changing weight values.
Press any key to exit the hold function.
= “Stable hold 1” mode
After the scale is stable, the display shows the current weight value. Press any key to exit the hold
function.
= “Stable hold 2” mode
After the scale is stable, the display shows the current weight value. Re-zero the scale to exit the hold
function.