English booklet version - Salus Controls

English booklet version - Salus Controls
!
!
OPTIMA!ZigBee!Thermostat!
!
!
Quick!Start!Guide
Salus Controls Inc.
123 Townsend St. Level LL2
San Francisco, CA 94107
Version!1.0
For other language versions, please visit: www.salusinc.com
!
!
FCC&and&Industry&Canada&
LET’S&GET&STARTED.&
RF Radiation Exposure statement: This equipment complies with FCC and Industry
Canada RF radiation exposure limits set forth for an uncontrolled environment. This
equipment should be installed and operated with a minimum distance of 20
centimeters between the antenna and all persons.
Make sure you have the following items:
Industry&Canada&
Thermostat with
Mounting Plate
Trim plate
Screws and Anchors
Under Industry Canada regulations, this radio transmitter may only operate using an
antenna of type and maximum (or lesser) gain approved for the transmitter by
Industry Canada. To reduce potential radio interference to other users, the antenna
type and its gain should be so chosen that the equivalent isotropically radiated power
(e.i.r.p.) is not more than that necessary for successful communication.
This device complies with Industry Canada licence-exempt RSS standard(s). Operation
is subject to the following two conditions: (1) this device may not cause interference,
and (2) this device must accept any interference, including interference that may cause
undesired operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux
appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions
suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de
l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est
susceptible d'en compromettre le fonctionnement.
Wire Labels
2 x AA alkaline
batteries
User’s Manual
1
Quick Start Guide
10
!
!
FCC&Statements&
Turn&off&the&heating&and/or&cooling&
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference, and (2)
this device must accept any interference received, including interference that may
cause undesired operation.
In some regions, there may be a switch located near the furnace.
WARNING: Changes or modifications to this unit not expressly approved by the party
responsible for compliance could void the user’s authority to operate the equipment.
Turn OFF the breakers or remove the fuses to the heating and/or cooling
systems at the electrical panel.
&
NOTE: This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy, and if not
installed and used in accordance with the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
9
2
!
!
Determine&wiring&configuration&
duration of implied warranties of merchantability or fitness, so these
exclusions or limitations may not apply to you.
•
•
•
Remove the old thermostat to expose
the wiring terminals.
Take a picture of the wiring for future
reference.
Note the terminals attached to each
wire and attach the matching label to
the ends of the wires. Use the following
table as a reference.
* A jumper connects RC and RH as most combination heat and cooling systems use a
single transformer. For systems where separate transformers are used, remove the
jumper in place across the RC and RH terminals.
Optima Thermostat Wiring Reference
Gas, Electric, or Oil (non-HP)
Heat Pump (HP)
R or RC*
24 VAC for Cooling system
R or RC*
24 VAC for Cooling system
RH*
24 VAC for Heating system
RH*
24 VAC for Heating system
C
24 VAC common return
C
24 VAC common return
-Reserved
L
System monitor
st
st
Y or Y1
Single / 1 stage cooling
Y or Y1
Single / 1 stage compressor
nd
nd
Y2
2 stage cooling
Y2
2 stage compressor
st
W or W1
Single / 1 stage heating
W or W1
Emergency heat
nd
W2
2 stage heating
O/B
Changeover valve
G
Fan signal
G
Fan signal
-Reserved
-Reserved
3
No oral or written information or advice given by Salus or a Salus-authorized
representative shall modify or extend this warranty. If any term is held to be
illegal or unenforceable, the legality or enforceability of the remaining terms
shall not be affected or impaired.
Customer’s sole and exclusive remedy under this limited warranty is product
repair or replacement as provided herein. If a Product under warranty is
defective, the Customer may:
• contact the party (“Seller”) from which the Customer purchased the
Product to obtain an equivalent replacement product after the Seller has
determined that the Product is defective and the Customer is eligible for
a replacement, or,
• contact Salus Service at 4700 Duke Drive, Suite 200, Mason, OH 45040,
to determine whether the device qualifies for a replacement. If a
replacement is warranted and is shipped prior to the return of the
device under warranty, a credit card is required and a hold may be
placed on the Customer’s credit card for the value of the replacement
until the returned device is verified as eligible for replacement, in which
case, the Customer’s credit card will not be charged.
This warranty gives you specific legal rights, and you may also have other
rights that vary from jurisdiction to jurisdiction. If you have any questions
regarding this warranty, please write Salus at:
123 Townsend St. Level LL2
San Francisco, CA 94107
8
!
!
SALUS&WARRANTY&
Remove&old&thermostat&terminals&
Salus Controls Inc. (“Salus”) warrants that for a period of two (2) years
(“Warranty Period”) from the date of purchase by the consumer (“Customer”),
this device, excluding batteries (“Product”), shall be free of defects in
materials and workmanship under normal use and service in accordance
with all supplied instructions. During the warranty period, Salus shall, at its
option, repair or replace any defective Products, at no charge for the device.
Any replacement and/or repaired devices are warranted for the remainder of
the original Warranty Period or ninety (90) days, whichever is longer.
This warranty does not cover removal or reinstallation costs. This warranty
does not apply to any Product (i) which has been modified, repaired, or
altered, except by Salus or an authorized Salus representative, (ii) which has
not been maintained in accordance with any handling or operating
instructions supplied by Salus, or (iii) which has been subjected to unusual
physical or electrical stress, misuses, abuse, negligence or accidents.
This warranty is the only express warranty Salus makes for the Product. Any
implied warranties, including warranties of merchantability or fitness for a
particular purpose, are limited to the Warranty Period or the shortest period
allowed by law.
SALUS SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND,
INCLUDING ANY SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES
RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY
WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS
PRODUCT. Some states and provinces do not allow the exclusion or
limitation of incidental or consequential damages, or limitation on the
7
Remove the old thermostat wiring terminals
from the wall, taking care not to allow the
wiring to fall inside the wall.
Install&Mounting&Plate&
Remove the Mounting Plate from the back of
the Optima thermostat. Use the included wall
anchors and screws to attach the Mounting
Plate to the wall, making sure the wires run
through the center opening. Use the Trim Plate
vertically or horizontally if desired.
Attach&Wiring&
Before attaching the wires, match the wire
(using the labels) to its corresponding
terminal. Refer to the picture of the wiring
taken earlier if necessary.
•
Open the terminal by lifting the latch up.
•
Push each wire into the hole of the
terminal and push the latch down to
secure the wire.
4
TIP:! Wrap! the! wire! ends!
around!a!long!stick,!such!as!
a! pencil! to! keep! the! wires!
from!falling!into!the!wall.!
!
!
Install&Batteries&
Attach&Thermostat&To&Mounting&Plate&
Insert the alkaline batteries into the back of the
thermostat. Make sure the polarity of the
batteries is correct. After inserting the batteries,
the display will flash all the segments, followed by
the version number of the firmware, then display
US / CA with a blinking US.
Initial&Configuration&
When configuring the thermostat, press the + or – button or use the slider
ring to cause the desired value to blink, then press MODE to select the value.
Using the table at right,
select the country, then
the type of system.
After this configuration,
the
thermostat
will
display
the
Home
Screen, and be ready
for attachment to the
Mounting Plate.
Value
US
CA
HP
NON-HP
Description
United States – Configures thermostat for
use in the US.
Canada – Configures thermostat for use
in Canada
Heat Pump
Non Heat Pump – Gas, electric, or oil heat
O
B
Heat Pump with O reverse valve
Heat Pump with B reverse valve
FAN HE
FAN HG
Non-HP: Electric or Oil Heat
Non-HP: Gas Heat
5
Attach the thermostat to the Mounting Plate
by aligning the connector pins and the plastic
retention posts and pushing the thermostat
onto the Mounting Plate.
Make sure the connector pins are not bent
and that the thermostat is fully seated on
the Mounting Plate.
Turn&Power&Back&On&To&The&
HVAC&System&
Go to the electrical service panel or
furnace switch and turn the HVAC
system back on.
Configure&Thermostat&
The thermostat can now be used as a basic local thermostat. To enable the
enhanced features, additional settings need to be configured, such as pairing
with a connected home system. See the Configuring the Thermostat section in
the User’s Manual for more details.
6
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement