Foreword
Congratulations!
You have acquired a REMUC Remote Control System. We dare to say you have chosen one of the best devices available as REMUC combines seamlessly quality design and production with ease of use and reliability.
REMUC is a Finnish Avainlippu product, meaning its degree of domestic origin is over
50%.
More information: www.remuc.fi
All manuals are available in multiple languages from: www.remuc.fi/downloads
2 REMUC User Manual
Contents
Connecting the phone using Android, Meego or Symbian application .................. 17
Connect phone using SMS and/or phone calls ..................................................... 22
3 REMUC User Manual
1 General information
REMUC controller enables controlling of different electric equipment like gasoline powered heaters, alarms and remote control system by using a mobile phone. Controller communicates on GSM network using either IP or SMS connection, depending on the mobile phone type in use. A SIM card is needed with a data plan or SMS plan, depending on the selected control method.
1.1 Package contents
REMUC controller with an integrated antenna and SIM card reader
Cables needed for installation
Heat sensor with 2m installation cable
Illuminated usage button with 1,5m installation cable
QR sticker
Embelin SIM card (optional)
SIM card supplied by Embelin Ltd. cannot be used in any other target
than REMUC. Removing an activated Embelin SIM card from REMUC causes the SIM card to be blacklisted and closed.
Quick start for end user
Installer guide
1.2 Electrical features
Operational voltage
Operational temperature
Current consumption in stand-by
Operational range of the heat sensor
+9V...32V
-30...+80C
< 30mA (12V)
-55...+125C
4 REMUC User Manual
2 Important information
Warning! Always read usage-, safety-, and service instructions of the device to be controlled using REMUC.
CONTROLLER MUST BE INSTALLED SO THAT THE INSTALLATION NEVER
EXCEEDS GIVEN VOLTAGE AND CURRENT INPUT LIMITS. CURRENT INPUT
MUST BE GUARDED WITH A 5A FUSE
If the package contains an optional data SIM or a Prepaid SIM card, user may change it to any operator’s SIM card but Embelin Ltd. is not able to provide any support regarding any other SIM card than the one included in the package
REMUC should be installed by a professional service to ensure proper operation
PIN code for the SIM card must be one of the following: ”1234”, ”0000” or the PIN code query must be disabled completely
If any other SIM card is used than the one included in the package, SIM card functionality must be verified with a mobile phone before installation. This is because usually after installation the device is located in a hard-to-reach spot.
If the SIM card installed in REMUC does not have any kind of fixed rate data plan, switch data connection off by sending SMS “IP OFF” to REMUC.
5 REMUC User Manual
3 Installing the controller
Installation must be performed by a professional service. Controller must be placed in a dry place shielded from water. Under car dashboard is a good example.
3.1 Connector schematics
Installation cable wiring may vary, depending on the delivery version:
RC2A
RC2AE
RC2AL
Full connected cable
Basic installation cable (Eberspächer)
Basic installation cable (Webasto)
Cable
PIN
NO
COLOUR FUNCTION INFORMATION
1
BLACK Ground
2
ORANGE WBC
3
NC
4
NC
5
GRAY Button
6
GRAY
7
GRAY Input 1
8
VIOLET Input 2
9
RED V in
10
YELLOW Output1 (+)
(heater control)
11
WHITE
12
GREEN
Output2 (+)
(Fan control)
Button
13
BROWN Button
14
BROWN Temp sensor
15
NC
16
BLACK Ground x x x x x x x x x x
+0V...+24V
(>1V = active) x x x x x
+0V...+24V
(>1V = active)
+9V…+32V
(5A fuse needed)
Output 0,5A (no fuse)
V in
voltage (PIN 9) x x x x
Output 0,5A (no fuse)
V in
voltage (PIN 9) x x x x x x x
6 REMUC User Manual
3.2 Connecting the REMUC usage button
Installer should proceed with caution when assembling usage button connector. Wire contact going in the plug must be in correct orientation and of correct color, otherwise breakage may occur.
3.3 Connecting the heat sensor
The heat sensor included in the installation wire set can be installed outside or inside of the vehicle, depending on the preference.
3.4
Configuring inputs
Remuc has two inputs which can be used for example to connect home fire alarm or theft alarm. Input voltage must be between 0V…V in
, where >1V is regarded as an active state.
Inputs are on/off type.
Inputs can be used to relay alarm or state data to phone or web client. If your Remuc has a SIM card with a data plan, you can configure input settings in http://www.remuc.fi/settings
. Check [6.8 Web browser client] for detailed reference. You
can also configure inputs using mobile application. When adding a new control, choose
Switch as the type.
If you don’t have a data plan but use SMS to access Remuc, you can use INPUT and ACK
commands to manage inputs. See [8 SMS interface] for more details.
7 REMUC User Manual
4 REMUC usage button and status lights
REMUC controller has an illuminated usage button and two separate status leds: one for controller status and another for internal GSM modem.
4.1 Status lights
Controller status LED lit: Controller is active and network connection is established
GSM modem status LED blinks depending on the network activity
If controller status LED does not switch to continuously lit mode after 5 minutes from restart, check SIM card PIN code. PIN code MUST be “1234”, “0000” or disabled.
GSM antenna
TIP:
You can switch PIN code query off from SIM card by installing it temporarily to a mobile phone and using it’s settings to deactivate PIN query
Controller status LED
GSM modem status LED
SIM card slot
Webasto connector (not available in all models)
REMUC installation cable connector
8 REMUC User Manual
4.2 Usage button
REMUC controller installation includes a usage button which is used to control default output state, for example switch heater on/off. It can also be used to reset the controller.
Button use does not require GSM network coverage.
Usage button is illuminated to ease locating the button in dark.
When defined default output is active (for example car heater), button light is brightly illuminated.
4.3 Resetting the controller with usage button
RESET / RESTART
1. Press and hold usage button at least 10 seconds. Release button.
2. Status light on usage button blinks for 10 seconds. After this controller is reset.
3. REMUC is ready for use when usage button LED stops blinking.
FACTORY RESSET
1. Press and hold usage button for at least 10 seconds. Release button.
2. Status light in usage button blinks for 10 seconds. During this time press button shortly 3 times.
3. Controller will be reset to factory settings.
REMUC is ready for use when usage button LED stops blinking.
If REMUC does not have any SMS users configured, it will go into user addition mode automatically on reset. REMUC will leave user addition mode when a phone call is made to
REMUC or timeout occurs (30 minutes).
9 REMUC User Manual
5 Controller initialization and settings
The steps needed for REMUC controller initialization depend on the user’s mobile phone type and desired control method:
1
2
If only newer smart phones are used, initialization can be completed using QR code
printed on the controller casing. See chapter [5.2 Connecting phone using QR code]
If there’s at least one older type smart phone or a plain mobile phone in use, the phone number must be added to REMUC controller. Also mobile application must be configured
to connect correct REMUC controller. See chapter [5.3 Connecting the phone using
Android, Meego or Symbian application]
Mobile phone operating system Connection method
Mobile application available?
Yes
Needs to add user?
Ni
1
2
Android (e.g. Samsung Galaxy S II)
iOS (Apple iPhone)
Windows Phone (e.g. Nokia Lumia 800)
Android (e.g. Samsung Galaxy S II)
Symbian Belle (Other smart phones by
Nokia)
Meego (Nokia N9)
IP
SMS
Muut puhelinmallit
SMS
Yes
No
Yes
Yes
Android exists in both categories because there’s both data-driven and SMS-driven application available for it.
5.1 Choosing the SIM card
(Valid only if delivery contents did not include a SIM card)
REMUC system can be controlled with SMS message or by data connection. SMS messages are used with all regular mobile phones and also MeeGo,
Symbian and Android phones. Newer mobile phones like Windows Phone and iPhone connect using data connection.
TIP: Every REMUC state change generates one SMS (if SMS users have been configured).
10 REMUC User Manual
Do you have any of the following smart phones: iPhone, Windows
Phone, Android,
Symbian or MeeGo?
YES
Is your phone Apple iPhone, Windows
Phone, Android or do you want to use Remuc with web interface?
NO
NO
Remuc can be used with traditional phones by phone
calls and SMS messages.
YES
Data plan is needed.
Smallest/slowest data plan should be enough.
(<100MB/kk)
Is your phone Symbian or MeeGo?
YES
Only SMS messages are used when communicating with Remuc. Get a basic SIM deal with a cheap monthly cost.
11 REMUC User Manual
5.2 Connecting phone using QR code
QR code is a two-dimensional bar code found in every REMUC controller casing. It is a unique identification used to connect user’s smart phone to the correct controller.
There’s an application available for newer smart phones which can be connected to correct REMUC just by taking a picture of the QR code on REMUC casing.
When QR code is used to connect phone to REMUC controller, user configuration by
phone calls or SMS messages is not needed.
Prerequisites
Familiarize yourself with usage, service and safety instructions supplied with the device that is controlled using REMUC.
Make sure REMUC controller has an active SIM card with a packet data plan.
SIM card PIN code must be either “1234”, “0000” or PIN query completely disabled
REMUC controller has been installed to your car
12 REMUC User Manual
Get the mobile application from the phone software market
Every smart phone operating system has its own marketplace for free and non-free applications user can download to their mobile phone. REMUC controller application is available in the following stores:
Search from Play Store:
“remuc controller” or use QR code below:
Search from Marketplace:
“remuc controller” or use QR code below:
Search from App Store:
“remuc controller” or use QR code below:
13 REMUC User Manual
Connect mobile application to REMUC controller (Windows Phone)
1 by clicking REMUC icon
2
Launch mobile application Select “Add remote”
3
Select ID field to activate camera
4
Use mobile device camera to shoot QR code in REMUC sticker
5
Accept new remote
6
You’re done! Left icon switches heating on and clock icon shows timers.
14 REMUC User Manual
1
Connect application to REMUC controller (Android)
2 application by clicking REMUC icon
3
Select ”Data plan”
4
Select ”Capture QR code”
5 6 7
Use mobile device Accept new device You’re done! Left camera to shoot QR by cliking ”Create” code in REMUC sticker icon switches heating on and clock icon shows timers.
15 REMUC User Manual
Connect mobile application to REMUC controller ( iPhone)
1
Launch mobile application Select ”Add Remuc” by clicking REMUC icon
2 3
Click ”Scan device id” to start camera
4
Use mobile device camera to shoot QR code in REMUC sticker
5 6
Accept new remote by You’re done! Left icon clicking ”Done”. switches heating on and clock icon shows timers.
16 REMUC User Manual
5.3 Connecting the phone using Android, Meego or Symbian application
If user has a phone that uses SMS messages as
its connection method (category 2, check [5
Controller initialization and settings], it has to be
configured to REMUC as user. If there aren’t any previous SMS users, the phone number will be automatically added as such when configuring the mobile application. If there are previous users, one of them must allow the new user addition.
TIP: If you have previously used only QR code configurable smart phones, your REMUC most likely does not have configured
SMS users.
Prerequisites
Familiarize yourself with usage, service and safety instructions supplied with the device that is controlled using REMUC.
If the installed SIM card doesn’t have a flat rate data plan, switch data connection off after first user has been added. You can switch data connection off with an
SMS “IP OFF.
REMUC controller has been installed to your car
REMUC controller has an active SIM card (SMS plan preferred)
SIM card PIN code must be either “1234”, “0000” or PIN query completely disabled
When controlling REMUC with phone calls, caller ID blocking must not be active
17 REMUC User Manual
Get the mobile application from the phone software market
Mobile application is available to Android and all Nokia phones with Symbian Belle operating system. It is also available on MeeGo OS (Nokia N9)
Search Play Store for
“remuc” or use the QR code below:
Search Nokia Ovi Store for
“remuc” or use the QR code below:
Search Nokia Ovi Store for
“remuc” or use the QR code below:
18 REMUC User Manual
Option 1: REMUC does not have any previously added SMS user
Go directly to section “Connect mobile application to REMUC controller”.
Option 2: REMUC has a previously added user
Reset REMUC by pressing and holding usage button >10s.
REMUC restarts and goes into user addition mode
After the usage button status LED stops blinking, make a phone call to REMUC.
Call will be terminated automatically
Your phone number is now added as a REMUC user and you can control REMUC using calls and SMS
19 REMUC User Manual
Connect mobile application to REMUC controller (Symbian, MeeGo)
1 application by clicking
REMUC icon
2
Add new device by clicking “+” button
3
Insert name, REMUC
4
Add a new control by phone number and clicking and holding on click ”Add” just added service
5
Select ”Add control”
6
Enter name and click
”Add”
7
You’re done!
20 REMUC User Manual
Yhdistä mobiilisovellus REMUC:iin (Android)
1 by clicking REMUC icon
2
Launch mobile application Select ”Add device”
3
Select ”SMS plan”
4 5
Enter device name and Click ”Create” phone number
6
You’re done!
21 REMUC User Manual
5.4 Connect phone using SMS and/or phone calls
Prerequisites
Familiarize yourself with usage, service and safety instructions supplied with the device that is controlled using REMUC
If the installed SIM card doesn’t have a flat rate data plan, switch data connection off after first user has been added. You can switch data connection off with an SMS “IP OFF”.
REMUC controller has been installed to your car
REMUC controller has a working SIM card (SMS plan recommended)
SIM card PIN code must be either “1234”, “0000” or PIN query completely disabled
When controlling REMUC with phone calls, caller ID blocking must not be active
Add user to REMUC
Reset REMUC by holding usage button at least 10 seconds.
REMUC restarts and goes into user add mode
Once usage button led stops blinking, make a phone call to REMUC number
Call is terminated automatically
Your phone number is now added as a
REMUC user and you can control REMUC using calls and SMS
If this was the first user added, switch REMUC data connection off by sending an
SMS ”IP OFF”..
Start using REMUC
When your phone number is added to REMUC, you can start using controller. You can switch default output on and off by making a phone call to controller. More advanced control can be achieved using SMS commands.
22 REMUC User Manual
5.5 Web user interface
In address http://www.remuc.fi/settings you can find a web page which allows your
REMUC settings modification. More details are in section [6.8 Web browser client].
23 REMUC User Manual
6 REMUC usage
REMUC can be used in many different ways:
with usage button
with phone calls
with SMS messages
using mobile application on following platforms: o
Windows Phone o
Android o
Apple iPhone o
Nokia Symbian Belle, MeeGo
Requirements for normal usage are that controller is installed successfully to the target, there’s a tested and working SIM card installed, controller is powered on and it’s successfully connected to GSM network. Functionality can be verified from usage button light. After logging into network it stops blinking and is left lightly illuminated.
Usage button and phone calls control the default output on and off immediately. SMS messages allow more advanced control: output on time, switch on delays can be controlled freely. Also, different configuration settings are controller with SMS.
Mobile applications are able to control all REMUC output both immediately and scheduled.
You can also define recurring switching, for example: “switch output 1 on for an hour every weekday at 07:30”.
24 REMUC User Manual
6.1 Windows Phone application
See chapter [5.2 Connecting phone using QR code], on how to connect the first mobile
phone.
REMUC name
REMUC status information
Control icon and state
Control name
Control scheduling
Additional functions
Add a new control
Return to previous view
25 REMUC User Manual
Switching control state
State switching is done by clicking the state icon. The light under the icon is green when that output is active.
Control output timers
Scheduling allows delaying of state switching, defining how long output is switched on and creating of recurring timers.
All previously defined timers can be viewed by clicking the clock icon. Adding and removal is also done there.
All Windows Phone timers are REMUC-specific, meaning that all timers added on one phone will be seen in all other phones defined to control REMUC.
Additional features
Add remote: Add a new REMUC to connect to. If the REMUC already has configured users, must one of the previous users approve adding of the new user.
When adding new remote, user defines a password which will be shown to previous users through the mobile application. New user won’t be able to control REMUC if the adding is not approved by any of the previous users. (in the approval dialog:
Master user can approve new users, Regular user cannot)
Modify settings: Rename REMUC or set REMUC in Service Mode, see chapter
Delete remote: Deletes the previously added REMUC
Application settings
- Notifications: Switches background notifications on/off. If notifications are switched off, mobile application won’t get any status updates from REMUC when left to background. It is recommended to be left on.
- Information about the mobile application.
Switching between multiple configured REMUC remotes
If you have more than one REMUC configured in the application, you can switch between them by panning horizontally.
Configuring multiple control for one REMUC remote
Depending on the installation, you can define more than one control for one REMUC remove. Additional control can be, for example, a fan/ventilation control (output) or a car alert status icon (input).
Removing a control
Press and hold on control name text. Dialog opens with an option “Delete control”.
26 REMUC User Manual
6.2 Apple iPhone application
See chapter [5.2 Connecting phone using QR code], on how to connect the first mobile phone.
REMUC name
REMUC status information
Control name
Add new remote
Information about the application
Control scheduling
27 REMUC User Manual
Switching control state
State switching is done by clicking the state icon. The light under the icon is green when that output is active.
Control output timers
Scheduling allows delaying of state switching, defining how long output is switched on and creating of recurring timers.
All previously defined timers can be viewed by clicking the clock icon. Adding and removal is also done there.
All Apple iPhone timers are REMUC-specific, meaning that all timers added on one phone will be seen in all other phones defined to control REMUC
Adding new REMUC remotes
If the REMUC already has configured users, must one of the previous users approve adding of the new user. When adding new remote, user defines a password which will be shown to previous users through the mobile application. New user won’t be able to control
REMUC if the adding is not approved by any of the previous users. (in the approval dialog:
Master user can approve new users, Regular user cannot)
REMUC-specific settings
Remote-specific settings can be accessed by clicking the remote name.
Service Mode
Service mode is needed when accessing REMUC device settings using web
user interface. See chapter [5.5 Web user interface]
Configuring multiple controls
Depending on the installation, you can define more than one control for one
REMUC remove. Additional control can be, for example, a fan/ventilation control (output) or a car alert status icon (input).
Removing a control
Press and hold on control name text. Choose ”Delete OUT <number>”.
28 REMUC User Manual
6.3 Android application
See chapter [5.2 Connecting phone using QR code], on how to connect the first mobile phone.
REMUC information
Control status and icon
Control name and type
Control scheduling
Return to previous view
29 REMUC User Manual
Placing the widget on home view
Android application also includes a widget which can be added into home view. Widget allows quick REMUC output switching without starting the application itself. Note: Widget can’t be added to home view if there are no remotes or controls defined in the application.
Switching control state
State switching is done by clicking the state icon. The light under the icon is green when that output is active.
Control output timers
Scheduling allows delaying of state switching, defining how long output is switched on and creating of recurring timers.
All previously defined timers can be viewed by clicking the clock icon. Adding and removal is also done there.
All timers created when using data connection mode are REMUC-specific, meaning that other mobile phones using the same REMUC see them also.
If application connection method is SMS, are timers phone-specific.
Timer can be removed by clicking it.
REMUC-specific settings
REMUC-specific settings can be accesses by pressing and holding on device name or icon.
Add control: Depending on the hardware installation, you may add more than one control pre device. Additional device can be, for example a vent control (output) or alert status (input)
Refresh: Refresh device status. Usually status refreshes automatically only when some state changes.
Modify: Change device name, defined phone number (only SMS usage) and device color on widget.
Delete: Deletes the device
SMS log (only applicable on SMS connection mode): Displays the SMS message traffic between REMUC device and the mobile phone. Sending messages also possible from this view.
Modifying and deleting controls
Press and hold on control name. In the opening dialog there’s ”Modify” and ”Delete control”.
30 REMUC User Manual
6.4 Symbian and MeeGo applications
Symbian and MeeGo application are very similar to Android version, so refer to chapter
6.5 Phone calls
REMUC can also be controlled using plain phone calls if user’s phone number is added to REMUC users. When a call is made to
REMUC number, it will be disconnected automatically and default output will switch state immediately.
TIP: If mobile application is installed on
Symbian or MeeGo phone, all SMS traffic between the phone and REMUC can be viewed in the application’s ”SMS Log” view.
REMUC messages will not be visible in the phone’s own messaging application.
6.6 SMS messages
Example SMS messages:
Description
Output 1 ON indefinitely
Output 1 OFF
Output 2 ON for 60 minutes
Output 1 ON for 30 minutes (1800 s), starting after
12 hours (720 min)
Output and input status query
Add next caller as USER in user database
SMS message
”OUT 1 ON 0”
”OUT 1 OFF”
”OUT 2 ON 3600”
”OUT 1 ON 1800 720”
”STATUS”
”CALLADD”
All SMS commands are described in detail in section [TBD]
6.7 Usage button
Usage button can be used to switch default output on and off independently from GSM network coverage, defined users or connected mobile phones.
31 REMUC User Manual
6.8 Web browser client
Web client can be found from http://www.remuc.fi/settings , but it’s also accessible from www.remuc.fi
front page. Login is done with QR code or a previously defined alias. You can log in without password if you set Remuc into service mode.
QR code is a device specific, unique 16 character identification.
You can access a feature specific online help by moving the mouse cursor on top of the orange question mark .
SERVICE MODE
Service mode allows logging in to Remuc web client without password. Service mode can be set using the mobile client or a SMS “SET SERVICE ON”. Service mode is disabled automatically in 60 minutes.
32 REMUC User Manual
6.8.1 Control tab
“Control” tab allows adding, removing and modifying of Remuc device controls. You can also add and remove single and recurring timers.
33 REMUC User Manual
6.8.2 SIM card tab
If you have an activated Embelin-supplied SIM card in your Remuc device, there will be a
SIM card tab available also in the web client. In SIM card tab you can see how much paid use time you have left on your Embelin SIM card. When mobile application notifies user about the SIM subscription expiration, you can go to this tab to renew SIM subscription.
If the package did not include an Embelin SIM card or your card subscription has expired, this tab is not visible.
34 REMUC User Manual
6.8.3 Settings tab
Last tab is labeled “Settings”. There you can modify all Remuc specific settings.
35 REMUC User Manual
7 REMUC settings
General settings
Default output
Temp unit
Allow roaming
Button led boost
Low voltage cutoff
Timeout after signal lost
Password for device manager
Selected default output which can be controlled with phone calls and usage button
Celsius or Fahrenheit
Allow network roaming
Led indicator light intensity
Disable all control if voltage under defined limit
Timeout after which all outputs are switched off if GSM network coverage is lost.
Define password to access this device manager without settings the Remuc to service mode
Webasto®
Webasto emulation mode
Webasto / OUT1 parallel mode
Choose which Webasto controller type Remuc will emulate
Enable OUT1 automatically when Webasto heating or ventilation is enabled
Inputs
* Configure when to send status messages about output changes
Acknowledgement
Reporting
Send next status message only if user has acknowledged the previous one
Status message is sent on chosen levels of input signal
Output timeouts
Defines the default ON time for outputs when switched on without specified duration (e.g. ”OUT 1
ON”)
SMS-users
* Configure REMUC users
User phone number
Delete data connection users
Added phone number
Remove all data connection users from Remuc
Aliases
Define a free formed shortcut for most used commands.
For example:
Alias: ”WARM”
Command: ”OUT 1 ON 3600”
36 REMUC User Manual
8 SMS interface
REMUC can be controlled extensively using SMS messages. Use of SMS messages require that the user phone number is added to REMUC user groups using CALLADD command.
OUTPUT CONTROL [OUT] ............................................................................................... 38
INPUT CONFIGURATION [INPUT] ................................................................................... 38
INPUT STATUS CHANGE ACKNOWLEDGEMENT [ACK] ............................................... 39
STATUS QUERY [STATUS] .............................................................................................. 39
GENERAL INFO QUERY [INFO] ....................................................................................... 39
REMUC SMS USERS [USERS] ........................................................................................ 39
ADDING A USER BY CALLING [CALLADD] ..................................................................... 39
REMOVING A USER BY CALLING [CALLDEL] ................................................................ 39
REMOVE A USER [DEL] ................................................................................................... 40
SET BALANCE LIMIT [BALANCE SET] ........................................................................... 40
QUERY BALANCE [BALANCE] ......................................................................................... 40
MANUAL NETWORK SELECTION [NETWORK] .............................................................. 41
RESET ............................................................................................................................... 41
DATA CONNECTION CONFIGURATION [IP] ................................................................... 41
SETTINGS [SET] ............................................................................................................... 42
37 REMUC User Manual
OUTPUT CONTROL [OUT]
Action:
Set selected output state. Return message contains status of all outputs, current temperature from both sensors and current voltage level
Command:
Parameters:
OUT <PORT> <STATE> <OUTPUTTIME> <STARTDELAY>
Examples:
Response:
Action:
Command:
VARIABLE DESCRIPTION
PORT
Output number
STATE
Output state
OUTPUTTIME
ON duration (s)
VALUE DEFAULT
1,2,H,V
ON/OFF
0-65534 If not given, output will stay on for the duration of OUTTIME-setting. For
OUT1 and OUT2 0 means it will stay on indefinitely. Outputs H and V can be ON only the maximum time of the heater connected on the WBUS.
STARTDELAY
Output set delay
(min)
0-65534 If not given or 0, start will set without delay
OUT 1 ON
OUT H ON
OUT 1 ON 45 900
OUT 2 ON 1800
Output 1 ON, stays ON for OUTTIME seconds.
Output 1 ON indefinitely
Output 1 ON for 45 s, switch on delay 15h (900 min)
Output 2 ON for 1800 s (30 min)
REMU STATUS <variable>:<value>...
REMU STATUS OUT1:ON OUT2:OFF IN1:LOW IN2:LOW T1:20C T2:10C V:12.3V
INPUT CONFIGURATION [INPUT]
Action:
Modify status reporting conditions for the selected input
Command:
Parameters:
INPUT <index> <edge> <ack>
Examples:
Response:
Example response:
VARIABLE DESCRIPTION index
Input port number
edge
Choose whether to report on rising, falling or both signal edges. (rise, falling, both, none)
ack
Require acknowledgement before next status message?
R = Input status stays up after change until acknowledged
F = Input status stays down after change until acknowledged
B = Input stays in the state after change until acknowledged
N = No acknowledgement required
VALUE
1-2
R, F, B, N
R, F, B, N
DEFAULT
INPUT 1 R R Sends a message when input 1 goes up. Stays up until acknowledged.
INPUT 2 B N Sends a message every time input 2 switches state.
REMU INPUT <index>:<edge>:<ack>...
REMU INPUT 1:B:B 2:R:R
38 REMUC User Manual
INPUT STATUS CHANGE ACKNOWLEDGEMENT [ACK]
Action:
Acknowledge input signal change report.
Command:
ACK <index>
Parameters:
Examples:
Response:
VARIABLE DESCRIPTION index
Input number
VALUE
1-2
ACK 2 Acknowledge report from input 2 signal change
REMU STATUS <variable>:<value>...
DEFAULT
REMU STATUS OUT1:ON OUT2:OFF IN1:LOW IN2:LOW T1:20C T2:10C V:12.3V
STATUS QUERY [STATUS]
Action:
Command:
Examples:
Response:
Example response:
Returns all output, input, temperature and voltage statuses
STATUS
STATUS
REMU STATUS <variable>:<value>...
REMU STATUS OUT1:ON OUT2:OFF IN1:LOW IN2:LOW T1:20C T2:10C
V:12.3V
GENERAL INFO QUERY [INFO]
Action:
Returns the amount of outputs and inputs, service mode status, offline status, default output number, low voltage cutoff limit and automatic heating setting.
Command:
Examples:
INFO
INFO
Response:
Example response:
REMU INFO <variable>:<value>...
REMU INFO OUTPUTS:4 INPUTS:2 HW:1 SQ:1 SERVICE:ON OFFLINE:OFF
DEFOUTPUT:1 UVOLTAGE:7.5V HEAT:OFF
REMUC SMS USERS [USERS]
Action:
Command:
Returns all users
USERS
Examples:
Response:
Example response:
USERS
REMU USERS <index>:<number>...
REMU USERS 0:+358401231234 1:+358501123344 2:+358441123321
ADDING A USER BY CALLING [CALLADD]
Action:
Adds next caller to controller user database. Mode is active for 5 minutes or until call arrives. Call must not be made before controller replies with”REMU WAITING CALL”.
Command:
Examples:
CALLADD
REMU WAITING CALL
(controller waits call for 5 minutes)
REMU USERS <index>:<number>...
(added user shown on list)
Response:
REMU WAITING CALL
REMU USERS 0:+358401231234 1:+358501123344 2:+358441123321
REMOVING A USER BY CALLING [CALLDEL]
Action:
Removes next calling number from user database. Controller waits call for 5 minutes.
Call must not be made before controller reports”REMU WAITING CALL”.
Command:
Examples:
CALLDEL
CALLDEL
Response:
REMU WAITING CALL
(controller waits call for 5 minutes)
REMU USERS <index>:< number>...
(just removed user is not in this list anymore)
Example response:
REMU WAITING CALL
REMU USERS 0:+358401231234 1:+358501123344
39 REMUC User Manual
REMOVE A USER [DEL]
Action:
Removes user from selected slot
Command:
DEL <index>
Parameters:
Examples:
Response:
VARIABLE DESCRIPTION VALUE index
Muistipaikka 0 - 9
DEFAULT
DEL 2 Removes user from slot 2
REMU USERS <index>:<number>...
REMU USERS 0:+358401231234 1:+358501123344 2:+358401233211
SET BALANCE LIMIT [BALANCE SET]
Action:
Sets a SMS cost-based use limit for the controller. Meant especially for prepaid usage.
Command:
Parameters:
BALANCE SET <balance> <price> <notify>
Examples:
Response:
VARIABLE DESCRIPTION balance
Total balance (cents)
price
One SMS cost
(cents)
notify
Notify limit
(cents)
VALUE
0-
0-
0-
DEFAULT
BALANCE SET 30000 20 2000 Set total balance to 300€, one SMS costs 0,20€ and notification SMS received when total balance under 20€
REMU BALANCE <balance> <price> <notify>
REMU BALANCE 30000 20 2000
QUERY BALANCE [BALANCE]
Action:
Returns balance, sms cost, notify limit
Command:
Examples:
BALANCE
Response:
Example response:
BALANCE
REMU BALANCE <balance> <price> <notify>
REMU BALANCE 30000 20 2000
LIST AVAILABLE NETWORKS [NETWORK]
Action:
Returns a list of available GSM networks
Command:
NETWORK
Examples:
Response:
Example response:
NETWORK
REMU NETWORK <auto> <index>:<name>…
REMU NETWORK A 0:*elisa
40 REMUC User Manual
MANUAL NETWORK SELECTION [NETWORK]
Action:
Selects given GSM network manually or sets the automatic mode
Command:
NETWORK <index>
Parameters:
Examples:
Response:
Action:
VARIABLE DESCRIPTION VALUE index
Index of the 0 - / A network
DEFAULT
NETWORK 2 Use network number 2
NETWORK A Enable automatic network selection
REMU NETWORK <auto> <index>:<name>…
REMU NETWORK M 0:*elisa 1:dna 2:SONERA
RESET
Action:
Command:
Examples:
Response:
Example response:
Restarts REMUC. Does not affect any settings.
RESET
RESET
-
-
DATA CONNECTION CONFIGURATION [IP]
Action:
Command:
Parameters:
Enables and disables REMUC IP connection.
IP <state>
Examples:
Response:
Example response:
VARIABLE DESCRIPTION DESCRIPTION state
IP connection ON/OFF possible
IP ON
IP OFF
IP <state> <remote server ip>
Enables data connection
Disables data connection
IP ON 80.75.106.230
DEFAULT
ON
41 REMUC User Manual
SETTINGS [SET]
Action:
M odify controller settings
Command:
Parameters:
SET <variable> <value>
Examples:
Action:
VARIABLE DESCRIPTION
OWNNUMBER
Own phone number
SERVICE
OFFLINE
Service mode
Offline mode
APN
USERNAME
PASSWORD
TEMPUNIT
DEFOUTPUT
Operator access point
Operator data connection user name
Operator data connection user password
Temp unit
Default output, controllable by phone and usage button
A = Automatic selection, depends on the controllable device
UVOLTAGE
OUTTIME
HEAT
SLOFF
Low voltage cutoff (V)
Default output ON-time(seconds).
Maximum value for H and V depends on the connected heater.
Controller internal heating, switches on only when needed
Switch all outputs off if loses network for given minutes
ROAMING
LEDBOOST
WBFAN
Enable/disable roaming
Choose usage button LED intensity when in OFF state
Enable OUT1 automatically when Webasto heating or Ventilation (OUTH, OUTV) is enabled
OFF = disabled
0-254 = start delay in minutes
SET SERVICE OFF
SET APN internet.saunalahti
Disables service mode
VALUE
ON/OFF
ON/OFF string (teksti) string (teksti) string (teksti)
C/F
1,2,H,V,A
0 – 30
0-65535
ON/OFF
0 = OFF
1-255
ON/OFF
ON/OFF
OFF
0-254
Sets access point to internet.sau””nalahti
DEFAULT
””
””
C
A
-
ON
OFF
”internet”
7.5
3600
OFF
0
OFF
ON
0
SET UVOLTAGE 10.8
SET DEFOUTPUT 2
Sets low voltage cutoff to 10.8V
Sets output port 2 as default port
Command:
REMU INFO <variable>:<value>...
Parameters:
REMU INFO OUTPUTS:2 INPUTS:2 HW:5 SW:7 SERVICE:ON OFFLINE:OFF DEFOUTPUT:2
UVOLTAGE:10.8 HEAT:OFF SLOFF:0 ROAMING:OFF WB:YES WBFAN:0 LEDBOOST:ON
42 REMUC User Manual
9 CE certification
This device fulfills CE-certificate EN 50498 (2010).
Embelin Ltd. declares that Remuc conforms directive 1999/5/EC relevant standards and regulations. Full Declaration of Conformity is in address http://www.embelin.fi/uploads/pdf/Remuc-DoC.pdf
10 WEEE directive
This symbol indicates that this product is not to be disposed of with your household waste, according to the WEEE Directive (2002/96/EC) and your national law. This product should be handed over to a designated collection point, e.g., on an authorized one-for-one basis when you buy a new similar product or to an authorized collection site for recycling waste electrical and electronic equipment (WEEE).
11 User manual
This user manual is prepared thoroughly. Constant product development may cause some information to end being out of date. Embelin Ltd. reserves the right to modify this user manual without any further notice. Embelin Ltd. disclaims any responsibility of any possible technical or delivery related errors, lack of information, random or direct damages caused by the quality or usage of this material.
12 Changes
Embelin Ltd. reserves all rights to modify product or user manual without any further notice.
13 Liability notice
Use of this product happens at your own risk.
Embelin Ltd. will not guarantee fault free function, performance or any accuracy of the information displayed.
Embelin Ltd. disclaims any responsibility to any property and/or personal damage caused by the use of this product.
© 2013 Embelin Ltd. – all rights reserved
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 2 Foreword
- 3 Contents
- 4 1 General information
- 4 1.1 Package contents
- 4 /
- 4 1.2 Electrical features
- 5 2 /Important information
- 6 3 Installing the controller
- 6 3.1 Connector schematics
- 7 3.2 Connecting the REMUC usage button
- 7 3.3 Connecting the heat sensor
- 7 3.4 Configuring inputs
- 8 4 REMUC usage button and status lights
- 8 4.1 Status lights
- 9 4.2 Usage button
- 9 4.3 Resetting the controller with usage button
- 10 5 Controller initialization and settings
- 10 5.1 Choosing the SIM card
- 12 5.2 Connecting phone using QR code
- 17 5.3 Connecting the phone using Android, Meego or Symbian application
- 22 5.4 Connect phone using SMS and/or phone calls
- 23 5.5 Web user interface
- 24 6 REMUC usage
- 25 6.1 Windows Phone application
- 27 6.2 Apple iPhone application
- 29 6.3 Android application
- 31 6.4 Symbian and MeeGo applications
- 31 6.5 Phone calls
- 31 6.6 SMS messages
- 31 6.7 Usage button
- 32 6.8 Web browser client
- 33 6.8.1 Control tab
- 34 6.8.2 SIM card tab
- 35 6.8.3 Settings tab
- 36 7 REMUC settings
- 37 8 SMS interface
- 38 OUTPUT CONTROL [OUT]
- 38 INPUT CONFIGURATION [INPUT]
- 39 INPUT STATUS CHANGE ACKNOWLEDGEMENT [ACK]
- 39 STATUS QUERY [STATUS]
- 39 GENERAL INFO QUERY [INFO]
- 39 REMUC SMS USERS [USERS]
- 39 ADDING A USER BY CALLING [CALLADD]
- 39 REMOVING A USER BY CALLING [CALLDEL]
- 40 REMOVE A USER [DEL]
- 40 SET BALANCE LIMIT [BALANCE SET]
- 40 QUERY BALANCE [BALANCE]
- 41 MANUAL NETWORK SELECTION [NETWORK]
- 41 RESET
- 41 DATA CONNECTION CONFIGURATION [IP]
- 42 SETTINGS [SET]
- 43 9 /CE certification
- 43 10 /WEEE directive
- 43 11 User manual
- 43 12 Changes
- 43 13 Liability notice