When you contact your Dealer regarding service or warranty please quote the model number and serial number as shown on the heater control panel inside the control access door.

OWNER’S MANUAL

Wall Furnace - WF2000

612195g

Warranty Service

Australia 1-300-650-644 seeleyinternational.com

It is the policy of Seeley International to introduce continual product improvement. Accordingly, specifications are subject to change without notice. Please consult with your dealer to confirm the specifications of the model selected.

seeleyinternational.com.au

AU 1102

(English) (WF2000)

2

OPERATING INSTRUCTIONS

Care Instructions

External surfaces should be cleaned with warm water and detergent with the heater turned off. Do not use abrasive cleaners as scratching of the surface will occur.

Recommended Maintenance

Periodic maintenance of your Braemar

Wall Furnace will ensure a long and satisfactory service life with the heater delivering optimum performance.

It is recommended that you contact your authorised Braemar service agent to arrange a routine maintenance check at the start of each heating season.

Service and maintenance work must only be carried out by Authorised personnel.

Fan

Auto / Boost switch

Warning

Do not place articles on or against this appliance.

Do not use or store flammable materials near this appliance.

Do not spray aerosols in the vicinity of this appliance while it is in operation.

Do not modify this appliance.

Pilot meter

WF2000

Igniter button

Gas control knob

OPERATING INSTRUCTIONS

Introduction

For satisfactory performance of your

Braemar gas wall furnace, please read these instructions carefully. The operation of the heater is controlled by the gas control knob and fan switch located behind the access door on the front cover.

Heat Setting

- Turn gas control knob anti-clockwise to

desired heat setting between “1” and

“7”.

- The heater will automatically adjust the

gas flow to maintain the room

temperature corresponding to the

selected heat setting.

Fan Operation

The fan will start automatically in both

AUTO and BOOST positions when the unit is warm enough after the burner is turned on, and stop automatically when the unit has cooled sufficiently after the burner turns off. With AUTO selected the unit will automatically select between "low" and "normal" (and

“boost” on 40MJ models) fan speeds based on the heated air temperature - no further user adjustment is necessary.

When BOOST is selected the fan will run only on its boost speed. It is recommended that the manual fan switch be set to AUTO for normal operation, or BOOST for rapid heat-up.

To Increase Heat Setting

- Turn gas control knob anti-clockwise

towards “7”.

To Decrease Heat Setting

- Turn gas control knob clockwise

towards “1”.

To Turn Off Main Burner

- Turn gas control knob clockwise

towards “PILOT” position. It is

recommended that the pilot be left in

operation during the heating season.

To Turn Off Completely (end of heating season)

- Turn gas control knob clockwise

to the “0” position.

Gas Control

To light the heater:

- Turn the gas control knob anti-

clockwise from the “0” position to the

position.

- Depress knob fully and hold down.

- Press the igniter button located next to

the gas control knob 3-4 times.

- Observe the pilot meter to indicate

operation of the pilot.

- Wait 20 seconds then release the gas

control knob and check the pilot meter

stays on.

- Repeat the process if required.

SEELEY INTERNATIONAL – OWNER’S MANUAL 3

advertisement