LPC2 C05 User Manual
USER MANUAL
Longo programmable controller
LPC-2.C05 module
Version 4
SMARTEH d.o.o. / Trg tigrovcev 1 / 5220 Tolmin / Slovenia / Tel.: +386(0) 388 44 00 / e-mail: [email protected] / www.smarteh.si
Longo programmable controller LPC-2.C05 module
Written by SMARTEH d.o.o.
Copyright © 2005, SMARTEH d.o.o.
User Manual
Document Version: 004
June 30, 2005
i
Longo programmable controller LPC-2.C05 module
STANDARDS AND PROVISIONS: Standards, recommendations, regulations
and provisions of the country in which the devices will operate, must
be considered while planning and setting up electrical devices. Work
on 230 VAC network is allowed for authorized personnel only.
DANGER WARNINGS: Devices or modules must be protected from
moisture, dirt and damage during transport, storing and operation.
WARRANTY CONDITIONS: For all modules LONGO LPC-2 – if no
modifications are performed upon and are correctly connected by
authorized personnel – in consideration of maximum allowed
connecting power, we offer warranty for 24 months from date of sale
to end buyer. In case of claims within warranty time, which are based
on material malfunctions the producer offers free replacement. The
method of return of malfunctioned module, together with description,
can be arranged with our authorized representative. Warranty does
not include damage due to transport or because of unconsidered
corresponding regulations of the country, where the module is
installed.
This device must be connected properly by the provided connection
scheme in this manual. Misconnections may result in device damage,
fire or personal injury.
Hazardous voltage in the device can cause electric shock and may
result in personal injury or death.
NEVER SERVICE THIS PRODUCT YOURSELF!
This device must not be installed in the systems critical for life (e.g.
medical devices, aircrafts, etc.).
If the device is used in a manner not specified by the manufacturer,
the degree of protection provided by the equipment may be impaired.
Waste electrical and electronic equipment (WEEE) must be collected
separately!
LONGO LPC-2 complies to the following standards:
•
EMC:EN 61000-6-2 (EN 50082), EN 61000-6-4 (EN 50081)
•
LVD: IEC 61131-2
•
Vibrations and climatic-mechanical: EN 60068-2-6, EN 60068-2-27,
EN 60068-2-29
MANUFACTURER:
SMARTEH d.o.o.
Trg tigrovcev 1
5220 Tolmin
Slovenia
ii
Longo programmable controller LPC-2.C05 module
Longo programmable controller LPC-2.C05 module
1 DESCRIPTION...................................................................................1
2 FEATURES.......................................................................................2
3 INSTALLATION..................................................................................3
3.1 Connection scheme....................................................................3
3.2 Mounting instructions.................................................................5
3.3 Module labeling........................................................................7
4 TECHNICAL SPECIFICATIONS..................................................................8
APPENDIX A: PROGRAMMERS GUIDE...........................................................9
5 CHANGES .....................................................................................11
6 NOTES..........................................................................................12
iii
Longo programmable controller LPC-2.C05 module
1 DESCRIPTION
LPC-2.C05 module is used for communication with mobile GSM equipment, like GSM phone or GSM
modem. The communication between LPC-2 system and mobile equipment is established through
SMS messages.
Up to eight digital and eight analog values could be represented from LPC-2 system as well as up to
eight digital and eight analog commands could be sent from GSM phone or other mobile equipment.
This commands could act direct to digital and analog outputs or can be used for parameter settings.
LPC-2 system can works also in alarming mode, where SMS alarm message is sent in case of
abnormal situation (temperature too high, water leakage, etc.). The SMS alarm messages are sent
recurrently every hour on first three phone numbers stored on the SIM card. If the phone numbers
are stored in the international notation (with country code) then the prefix must start with “00”
and not with “+” symbol (e.g. Slovenian international code is 00386).
When LPC-2.C05 module is correctly installed, then is ready to operate. In this case status LED1
must blink (refer to the Table 6). The starting sequence is executed once after reset. Complete time
base is 40 sec (see below).
a)
b)
c)
a) LED1 blinks once after reset and then is off – SIM card not inserted or SIM card PIN still enabled
b) LED1 blinks once after reset and then is on – GSM network problem; check antenna and GSM signal
level with the mobile phone
c) LED1 blinks once after reset and then start blinking – normal starting sequence; everything OK
IMPORTANT: The PIN number of the SIM card must be disabled otherwise LPC-2.C05 will not be
connected to the GSM network!
Module is powered from internal BUS.
NOTE: For proper system configuration and data allocation please refer to LPC Composer software
help menu.
1
Longo programmable controller LPC-2.C05 module
2 FEATURES
Figure 1: LPC-2.C05 communication
module
Table 1: Technical data
Dual band 900/1800 MHz
Optional RS232 communication port, 9600 bps, 8 bits, one stop bit, no parity, no flow control,
reserved for external AT command
Standard DIN EN50022-35 rail mounting
2
Longo programmable controller LPC-2.C05 module
3 INSTALLATION
3.1 Connection scheme
Figure 2: Connection scheme
K1
K2
ANT.
SIM CARD
LPC-2.C05
GSM module
Addr.:
LED
status
LED1
Table 2: ANT.
ANT.
Antenna connector
FME/M (GSM antenna FME/F)
Table 3: SIM CARD
SIM CARD
SIM card connector
Table 4: K1
Internal BUS
Data & DC power supply
Connection to I/O module
Data & DC power supply
Connection to I/O module
Table 5: K2
Internal BUS
3
Longo programmable controller LPC-2.C05 module
Table 6: LED1
Status
Green LED: indicates C05 state
OFF: power off
Blink once: SIM card not inserted
or PIN enabled
Blink once & ON: Low GSM signal
Blink: Normal starting sequence
4
Longo programmable controller LPC-2.C05 module
3.2 Mounting instructions
Figure 3: Housing dimensions
•
Dimensions in millimeters.
All connections, module attachments and assembling must be done
while module is not connected to the main power supply.
Mounting instructions:
1. Switch OFF main power supply.
2. Mount LPC-2.C05 module to the provided place inside an electrical panel (DIN EN50022-35
rail mounting).
3. Screw antenna (delivered together with LPC-2.C05 module) to the antenna connector.
4. Mount other LPC-2 modules (if required). Mount each module to the DIN rail first, then
attach modules together through K1 and K2 connectors.
5. Switch ON main power supply.
5
Longo programmable controller LPC-2.C05 module
Dismount in reverse order. For mounting/dismounting modules to/from DIN rail a free space of at
least one module must be left on the DIN rail.
NOTE: LPC-2.MC3 main control module should be powered separately from other electrical appliance
connected to LPC-2 system. Signal wires must be installed separately from power and high voltage
wires in accordance with general industry electrical installation standard.
6
Longo programmable controller LPC-2.C05 module
3.3 Module labeling
Figure 5: Labels on housing
Label 1 (MC3 sample):
Label 2 (MC3 sample):
Label 1 description:
1. LPC-2.MC3 is the full product name.
2. P/N:225MC3040001001 is the part number.
•
225 – general code for product family,
•
MC3 – short product name,
•
04001 – sequence code,
•
•
04 – year of code opening
•
001 – derivation code
001 – version code (reserved for future HW and/or SW firmware upgrades).
3. D/C:16/05 is the date code.
•
16 – week and
•
05 – year of production.
Label 2 description:
1. S/N:MC3-S9-0500000190 is the serial number.
•
MC3 – short product name,
•
S9 – user code (test procedure, e.g. Smarteh person xxx),
•
0500000190 – year and current stack code,
•
05 – year (last two cyphers)
•
00000190 – current stack number; previous module would have the stack number
00000189 and the next one 00000191.
7
Longo programmable controller LPC-2.C05 module
4 TECHNICAL SPECIFICATIONS
Table 7: Technical specifications
Power supply
from internal BUS
Power consumption
1W
Communication
Optional RS232 communication port, 9600 bps, 8
bits, one stop bit, no parity, no flow control,
reserved for external AT commands
Antenna connector
FME/M
Antenna impedance
50 Ω
Phone book capacity
100
SMS storage capacity
40 in ME (mobile equipment)
up to 25 in SIM (SIM dependent)
Frequency range
GSM 900 and GSM 1800
Dimensions (L x W x H)
90 x 53 x 60 mm
Weight
120 g
Ambient temperature
0 to 50 °C
Ambient humidity
max. 95 %, no condensation
Transport and storage temperature
-20 to 60 °C
Pollution degree
2
Protection class
IP 30
8
Longo programmable controller LPC-2.C05 module
APPENDIX A: PROGRAMMERS GUIDE
Memory allocation
Tables below shows the example of memory allocation for C05 on position #1.
Boolean variables Rx:
I/O Module
I/O Name
FBOOL8
BIT0
BIT1
BIT2
BIT3
Range
BIT4
BIT5
BIT6
BIT7
0..1
MC3: 0x1069 + (N * 0x0040)
MC7: 0x0702 + (N * 0x0040)
Address
Boolean variables Tx used to select the number of analogue (BIT0-BIT3) and digital (BIT4-BIT7) input
signals:
I/O Module
I/O Name
FBOOL8
BIT0
BIT1
BIT2
BIT3
Range
BIT4
BIT5
BIT6
BIT7
BIT6
BIT7
0..1
MC3: 0x1438 + (N * 0x0040)
MC7: 0x0101 + (N * 0x0040)
Address
Boolean variables Tx:
I/O Module
I/O Name
Range
Address
FBOOL8
BIT0
BIT1
BIT2
BIT3
BIT4
BIT5
0..1
MC3: 0x1439 + (N * 0x0040)
MC7: 0x0102 + (N * 0x0040)
9
Longo programmable controller LPC-2.C05 module
Word variables Rx:
I/O Module
I/O Name
FWORD16
WORD1
WORD2
WORD3
Range
WORD4
WORD5
WORD6
WORD7
WORD8
WORD7
WORD8
BIT6
BIT7
0..65535
MC3: 0x160a + (N * 0x0040)
MC7: 0x0703 + (N * 0x0040)
Address
Word variables Tx:
I/O Module
I/O Name
FWORD16
WORD1
WORD2
WORD3
Range
WORD4
WORD5
WORD6
0..65535
MC3: 0x143a + (N * 0x0040)
MC7: 0x0103 + (N * 0x0040)
Address
Boolean variable Tx used for alarming of the LPC-2 system(s):
I/O Module
I/O Name
Range
Address
FBOOL8
BIT0
BIT1
BIT2
BIT3
BIT4
BIT5
0..1
MC3: 0x144e + (N * 0x0040)
MC7: 0x0117 + (N * 0x0040)
N = module position number;
N of Main control unit is 0 and counts up by 1 with every next module
10
Longo programmable controller LPC-2.C05 module
5 CHANGES
The following table describes all the changes to the document.
Date
V.
Description
30.6.2005
003
The initial version, issued as LPC-2.C05 module UserManual.
11.5.2010
004
Updated warranty permanence.
11
Longo programmable controller LPC-2.C05 module
6 NOTES